Service Rinnova Cond Circuito Gas CIRCUITO GAS Service BRUCIATORE VENTILATORE DIAFRAMMI GAS VALVOLA GAS RINNOVA COND – CIRCUITO GAS VALVOLA GAS E DIAFRAMMI • Service • COMPITO MASSIMO – APRIRE/CHIUDERE IL GAS IN BASE ALLE GAS RICHIESTE – CHIUDERE IL GAS IN CASO DI INTERVENTO DELLE PROTEZIONI CARATTERISTICHE MINIMO GAS – MODELLO SIT 848 SIGMA – NUOVA MODELLO CON MEMBRANE PIU’ SENSIBILI CHE MIGLIORANO LA MODULAZIONE – OPERATORI ON - OFF ALIMENTATI A 220 V – NON INTERCAMBIABILE CON PARVA CONDENSING • DIAFRAMMI G20 G30/31 25 S 6,20 4,50 35 S 7,70 5,20 25 SV 6,40** 4,60** 30 SV 7,70** 5,20** ** IN ATTESA DI OMOLOGAZIONE RINNOVA COND – CIRCUITO GAS MIXER ARIA-GAS DIAFRAMMA ARIA Service • FUNZIONE: • MISCELARE ARIA E GAS IN INGRESSO AL VENTILATORE • RIDURRE RUMOROSITA’ IN FASE DI ACCENSIONE • CARATTERISTICHE : • DOTATO DI DIFRAMMA ARIA INTERNO DIVERSO IN BASE ALLA POTENZA MASSIMA DELLA CALDAIA: – 25 S - SV (2 ELEMENTI): FUCSIA – 35 S - SV (3 ELEMENTI): BLU • IN CASO DI CAMBIO GAS IL MIXER RIMANE LO STESSO RINNOVA COND – CIRCUITO GAS VENTILATORE Service • COMPITO – INVIARE AL BRUCIATORE LA MISCELA ARIA/GAS – EVACUARE I PRODOTTI DELLA COMBUSTIONE – MODULARE LA POTENZA DEL BRUCIATORE VARIANDO IL N° DI GIRI. • CARATTERISTICHE – MODELLO: EBM MRG118 – ALIMENTAZIONE ELETTRCA: 230V ca – POTENZA 60 W – COLLEGATO CON 2 CABLAGGI UNO DI POTENZA E UNO DI SEGNALE ALIMENTAZIONE 230 V SEGNALE CONTROLLO NUMERO DI GIRI RINNOVA COND – CIRCUITO GAS BRUCIATORE ED ELETTRODI • • Service COMPITO – PROGETTATO PER OTTIMIZZARE LA COMBUSTIONE A PREMISCELAZIONE CHE VIENE EFFETTUATA DAL SISTEMA VENTILATORE-VALVOLA GAS CARATTERISTICHE – BRUCIATORE ECOLOGICO IN ACCIAIO INOX AISI 316L – RIDOTTE EMISSIONI INQUINANTI DI Nox (CALDAIA CLASSE 5 NOX) – FACILMENTE ESTRAIBILE DAL FRONTALE – DUE MODELLI 24/32 KW – DUE ELETTRODI MONTATI: UNO DI SCARICA E UNO DI IONIZZAZIONE RINNOVA COND – CIRCUITO GAS PROCEDURA TARATURA GAS Service COME PER TUTTE LE CALDAIE A CONDENSAZIONE PREMISCELATE LE TARATURE DEL GAS SI ESEGUONO SOLO CON L’UTILIZZO DELL’ANALIZZATORE DI COMBUSTIONE E SEGUENDO LA PROCEDURA SOTTO INDICATA. REGOLAZIONE MINIMO GAS 1. ENTRARE IN MODALITA’ SPAZZACAMINO SEGUENDO LE IDICAZIONI SOTTO RIPORTATE: CHIUDERE IL CONTATTO TA TENERE PREMUTO I PULSANTI A-B-C IN FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’ PR ALTERNATO A 01 PREMERE CONTEMPORANEAMENTE I TASTI A e C FINO A QUANDO IL DISPLAY INDICHERA’ LP ALTERNATO AL VALORE DELLA TEMPERATURA DI MANDATA IMPOSTATA (FUNZIONE FORZATURA POTENZA MINIMA ATTIVATA) 2. PRELEVARE ABBONDANTE ACQUA SANITARIA 3. AVVIARE ANALIZZATORE DI COMBUSTIONE 4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (8,6% - 9,2%) A B C A C FUNZIONE SPAZZACAMINO ATTIVA RINNOVA COND – CIRCUITO GAS PROCEDURA TARATURA GAS Service 5. AGIRE SULLA VITE INICATA IN FIGURA PER MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA (AVVITANDO CO2 AUMENTA) REG. MINIMO GAS REGOLAZIONE MASSIMO GAS 1. PREMERE DIVERSE VOLTE IL TASTO A FINO A CHE IL DISPLAY NON INDICA DP ALTERNATO AL VALORE DELLA TEMPERATURA DI MANDATA IMPOSTATA (FUNZIONE FORZATURA MASSIMA POTENZA ATTIVATA) 2. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (9,2 – 9,8) 3. AGIRE SULLA VITE INDICATA IN FIGURA PER MODIFCARE IL VALORE DI CO2 ALLA MASSIMA POTENZA (AVVITANDO CO2 DIMINUISCE) TERMINATE LE OPERAZIONI SOPRA DESCRITTE, CHIUDERE ACS E SPEGNERE LA CALDAIA TENENDO PREMUTO IL TASTO B FIN CHE IL DISPLAY INDICA: A REGOLAZIONE MASSIMO GAS RINNOVA COND – CIRCUITO GAS PROCEDURA CAMBIO GAS SEGUIRE LE ISRUZIONI SOTTO RIPORTATE PER EFFETTUARE LA TRASFORMAZIONE GAS: 1. SOSTITUIRE IL DIAFRAMMA GAS 2. ENTRARE IN PROGRAMMAZIONE SEGUENDO LE ISTRUZIONI SOTTO RIPORTATE: TENERE PREMUTO I PULSANTI A-B-C IN FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’ PR ALTERNATO A 01 (PARAMETRO 1) PREMERE DIVERSE VOLTE I TASTI A o C FINO A CHE IL DISPLAY NON INDICA PR ALTERNATO A 05 (PARAMETRO 5) PREMERE CONTEMPORANEAMENTE I TASTI A e B: IL DISPLAY INDICHERA’ IL VALORE IMPOSTATO PER PR 05 (METANO=00 GPL=05) PREMERE IL TASTO A PER MODIFICARE IL VALORE: 00 05 PREMERE IL TASTO B PER MEMORIZZARE TENERE PREMUTO I PULSANTI A-B-C IN FIGURA (CIRCA 10 sec) PER USCIRE DALLA MODALITA’ DI PROGRAMMAZIONE Service A B C A/C RINNOVA COND – CIRCUITO GAS SICUREZZE TERMICHE NTC FUMI • COMPITO – VERIFICA LA TEMPERATURA FUMI PER TENERE SOTTO CONTROLLO LO SCAMBIO TERMICO ED EVITARE DANNI AL CONDOTTO FUMI • CARATTERISTICHE – CON LA TEMP. FUMI TRA 110°-120° C VIENE FORZATA LA MODULAZIONE – OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA DEDICATA (Er10 + RESET) – IN CASO DI GUASTO OGNI FUNZIONAMENTO E’ INIBITO (Er 09 + ) TERMOSTATO MASSIMA TEMPERATURA • COMPITO – BLOCCARE IL FUNZIONAMENTO IN CASO DI SOVRATEMPERATURE • CARATTERISTICHE – INTERVENTO A 105° C, RIARMO AUTOMATICO – DIAGNOSTICA DEDICATA (Er02 + RESET) Service NTC FUMI TERMOSTATO MASSIMA TEMPERATURA RINNOVA COND – CIRCUITO GAS SIFONE SCARICO CONDENSA • • Service COMPITO – CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO DEL GRUPPO CONDENSANTE – EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO CONDENSA CARATTERISTICHE – DIAMETRO RACCORDO COLLEGAMENTO: 25 mm. – TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE PLASTICO L= 45 cm – PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL CASO IL SIFONE SI ASCIUGHI – VERIFICA SCARICO CONDENSA: NELLA PARTE ALTA DEL SIFONE E’ COLLEGATO UN TERMINALE DEL CABLAGGIO DELL’ELETTRODO DI IONIZZAZIONE (PROTETTO DA CANOTTO). SE IL SIFONE NON SCARICA IL LIVELLO DI CONDENSA SALE FINO AL LIVELLO DEL CONNETTORE MANDANDO IN BLOCCO FIAMMA LA CALDAIA. RINNOVA COND – CIRCUITO GAS