Service
Rinnova Cond
Circuito Gas
CIRCUITO GAS
Service
BRUCIATORE
VENTILATORE
DIAFRAMMI GAS
VALVOLA GAS
RINNOVA COND – CIRCUITO GAS
VALVOLA GAS E DIAFRAMMI
•
Service
•
COMPITO
MASSIMO
– APRIRE/CHIUDERE IL GAS IN BASE ALLE
GAS
RICHIESTE
– CHIUDERE IL GAS IN CASO DI INTERVENTO DELLE
PROTEZIONI
CARATTERISTICHE
MINIMO GAS
– MODELLO SIT 848 SIGMA
– NUOVA MODELLO CON MEMBRANE PIU’ SENSIBILI
CHE MIGLIORANO LA MODULAZIONE
– OPERATORI ON - OFF ALIMENTATI A 220 V
– NON INTERCAMBIABILE CON PARVA CONDENSING
•
DIAFRAMMI
G20
G30/31
25 S
6,20
4,50
35 S
7,70
5,20
25 SV
6,40**
4,60**
30 SV
7,70**
5,20**
** IN ATTESA DI OMOLOGAZIONE
RINNOVA COND – CIRCUITO GAS
MIXER ARIA-GAS
DIAFRAMMA
ARIA
Service
•
FUNZIONE:
• MISCELARE ARIA E GAS IN INGRESSO AL
VENTILATORE
• RIDURRE RUMOROSITA’ IN FASE DI ACCENSIONE
•
CARATTERISTICHE :
• DOTATO DI DIFRAMMA ARIA INTERNO DIVERSO IN
BASE ALLA POTENZA MASSIMA DELLA CALDAIA:
– 25 S - SV (2 ELEMENTI): FUCSIA
– 35 S - SV (3 ELEMENTI): BLU
• IN CASO DI CAMBIO GAS IL MIXER RIMANE LO
STESSO
RINNOVA COND – CIRCUITO GAS
VENTILATORE
Service
•
COMPITO
– INVIARE AL BRUCIATORE LA
MISCELA ARIA/GAS
– EVACUARE I PRODOTTI DELLA
COMBUSTIONE
– MODULARE LA POTENZA DEL
BRUCIATORE VARIANDO IL N° DI
GIRI.
•
CARATTERISTICHE
– MODELLO: EBM MRG118
– ALIMENTAZIONE ELETTRCA: 230V
ca
– POTENZA 60 W
– COLLEGATO CON 2 CABLAGGI
UNO DI POTENZA E UNO DI
SEGNALE
ALIMENTAZIONE 230 V
SEGNALE CONTROLLO
NUMERO DI GIRI
RINNOVA COND – CIRCUITO GAS
BRUCIATORE ED ELETTRODI
•
•
Service
COMPITO
– PROGETTATO PER OTTIMIZZARE LA
COMBUSTIONE A
PREMISCELAZIONE CHE VIENE
EFFETTUATA DAL SISTEMA
VENTILATORE-VALVOLA GAS
CARATTERISTICHE
– BRUCIATORE ECOLOGICO IN
ACCIAIO INOX AISI 316L
– RIDOTTE EMISSIONI INQUINANTI DI
Nox (CALDAIA CLASSE 5 NOX)
– FACILMENTE ESTRAIBILE DAL
FRONTALE
– DUE MODELLI 24/32 KW
– DUE ELETTRODI MONTATI: UNO DI
SCARICA E UNO DI IONIZZAZIONE
RINNOVA COND – CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
COME PER TUTTE LE CALDAIE A CONDENSAZIONE
PREMISCELATE LE TARATURE DEL GAS SI ESEGUONO SOLO
CON L’UTILIZZO DELL’ANALIZZATORE DI COMBUSTIONE E
SEGUENDO LA PROCEDURA SOTTO INDICATA.
REGOLAZIONE MINIMO GAS
1. ENTRARE IN MODALITA’ SPAZZACAMINO SEGUENDO LE
IDICAZIONI SOTTO RIPORTATE:
 CHIUDERE IL CONTATTO TA
 TENERE PREMUTO I PULSANTI A-B-C IN FIGURA
(CIRCA 10 sec): IL DISPLAY INDICHERA’ PR
ALTERNATO A 01
 PREMERE CONTEMPORANEAMENTE I TASTI A e C
FINO A QUANDO IL DISPLAY INDICHERA’ LP
ALTERNATO AL VALORE DELLA TEMPERATURA DI
MANDATA IMPOSTATA (FUNZIONE FORZATURA
POTENZA MINIMA ATTIVATA)
2. PRELEVARE ABBONDANTE ACQUA SANITARIA
3. AVVIARE ANALIZZATORE DI COMBUSTIONE
4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO
RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA
(8,6% - 9,2%)
A
B
C
A
C
FUNZIONE SPAZZACAMINO
ATTIVA
RINNOVA COND – CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
5. AGIRE SULLA VITE INICATA IN FIGURA PER MODIFICARE
IL VALORE DI CO2 ALLA MINIMA POTENZA (AVVITANDO
CO2 AUMENTA)
REG. MINIMO
GAS
REGOLAZIONE MASSIMO GAS
1. PREMERE DIVERSE VOLTE IL TASTO A FINO A CHE IL
DISPLAY NON INDICA DP ALTERNATO AL VALORE DELLA
TEMPERATURA DI MANDATA IMPOSTATA (FUNZIONE
FORZATURA MASSIMA POTENZA ATTIVATA)
2. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO
RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA
(9,2 – 9,8)
3. AGIRE SULLA VITE INDICATA IN FIGURA PER
MODIFCARE IL VALORE DI CO2 ALLA MASSIMA POTENZA
(AVVITANDO CO2 DIMINUISCE)
TERMINATE LE OPERAZIONI SOPRA
DESCRITTE, CHIUDERE ACS E SPEGNERE LA
CALDAIA TENENDO PREMUTO IL TASTO B FIN
CHE IL DISPLAY INDICA:
A
REGOLAZIONE
MASSIMO GAS
RINNOVA COND – CIRCUITO GAS
PROCEDURA CAMBIO GAS
SEGUIRE LE ISRUZIONI SOTTO RIPORTATE PER
EFFETTUARE LA TRASFORMAZIONE GAS:
1. SOSTITUIRE IL DIAFRAMMA GAS
2. ENTRARE IN PROGRAMMAZIONE SEGUENDO LE
ISTRUZIONI SOTTO RIPORTATE:
 TENERE PREMUTO I PULSANTI A-B-C IN FIGURA
(CIRCA 10 sec): IL DISPLAY INDICHERA’ PR ALTERNATO
A 01 (PARAMETRO 1)
 PREMERE DIVERSE VOLTE I TASTI A o C FINO A CHE
IL DISPLAY NON INDICA PR ALTERNATO A 05
(PARAMETRO 5)
 PREMERE CONTEMPORANEAMENTE I TASTI A e B: IL
DISPLAY INDICHERA’ IL VALORE IMPOSTATO PER PR
05 (METANO=00 GPL=05)
 PREMERE IL TASTO A PER MODIFICARE IL VALORE:
00
05
 PREMERE IL TASTO B PER MEMORIZZARE
 TENERE PREMUTO I PULSANTI A-B-C IN FIGURA
(CIRCA 10 sec) PER USCIRE DALLA MODALITA’ DI
PROGRAMMAZIONE
Service
A
B
C
A/C
RINNOVA COND – CIRCUITO GAS
SICUREZZE TERMICHE
NTC FUMI
• COMPITO
– VERIFICA LA TEMPERATURA FUMI PER
TENERE SOTTO CONTROLLO LO SCAMBIO
TERMICO ED EVITARE DANNI AL CONDOTTO
FUMI
• CARATTERISTICHE
– CON LA TEMP. FUMI TRA 110°-120° C
VIENE
FORZATA LA MODULAZIONE
– OLTRE I 120°C BLOCCO FIAMMA E
DIAGNOSTICA DEDICATA (Er10 + RESET)
– IN CASO DI GUASTO OGNI FUNZIONAMENTO
E’ INIBITO (Er 09 +
)
TERMOSTATO MASSIMA TEMPERATURA
• COMPITO
– BLOCCARE IL FUNZIONAMENTO IN CASO DI
SOVRATEMPERATURE
• CARATTERISTICHE
– INTERVENTO A 105° C, RIARMO AUTOMATICO
– DIAGNOSTICA DEDICATA (Er02 + RESET)
Service
NTC FUMI
TERMOSTATO MASSIMA
TEMPERATURA
RINNOVA COND – CIRCUITO GAS
SIFONE SCARICO CONDENSA
•
•
Service
COMPITO
– CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO
DEL GRUPPO CONDENSANTE
– EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO
CONDENSA
CARATTERISTICHE
– DIAMETRO RACCORDO COLLEGAMENTO: 25 mm.
– TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE
PLASTICO L= 45 cm
– PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL
CASO IL SIFONE SI ASCIUGHI
– VERIFICA SCARICO CONDENSA: NELLA PARTE ALTA DEL
SIFONE E’ COLLEGATO UN TERMINALE DEL CABLAGGIO
DELL’ELETTRODO DI IONIZZAZIONE (PROTETTO DA
CANOTTO). SE IL SIFONE NON SCARICA IL LIVELLO DI
CONDENSA SALE FINO AL LIVELLO DEL CONNETTORE
MANDANDO IN BLOCCO FIAMMA LA CALDAIA.
RINNOVA COND – CIRCUITO GAS
Scarica

Rinnova Cond - gas