Service Rinnova Cond Circuito Idraulico CONNESSIONI Service MANOMETRO VALVOLA SCARICO SCARICO VALVOLA SICUREZZA ALIMENTAZIONE ELETTRICA GAS SIFONE TERMOSTATO AMBIENTE REMOTO + SONDA ESTERNA Rinnova Cond. - Idraulica CIRCUITO IDRAULICO Service Rinnova Cond. - Idraulica VASO DI ESPANSIONE • • Service COMPITO – COMPENSA L’AUMENTO DI PRESSIONE DETERMINATO DALL’AUMENTO DI TEMPERATURA DELL’ACQUA NELL’IMPIANTO DI RISCALDAMENTO DATI – CAPACITA’ TOTALE 7,0 LITRI – CAPACITA’ UTILE 3,5 LITRI – PRESSIONE DI PRECARICA 1 bar – CONTENUTO MASSIMO D’ ACQUA NELL’IMPIANTO 109 LITRI (85°C) Rinnova Cond. - Idraulica POMPA • • • Service COMPITO – IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO – IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO CARATTERISTICHE – COMPATTO – DISAREATORE INCORPORATO DATI – MODELLO WILO WHITE GOOD 12/5 – ALIMENTATO A 230 Vc.a. – PREVALENZA RESIDUA SUPERIORE 3 M.C.A ALLA PORTATA DI 1000 l/h A Rinnova Cond. - Idraulica SCAMBIATORE PRIMARIO E CONDENSANTE • • • COMPITO – SCAMBIARE CALORE TRA ACQUA PRIMARIA E FIAMMA – SCAMBIARE CALORE TRA ACQUA PRIMARIA E FUMI CARATTERISTICHE – COSTRUITO CON ELEMENTI IN ALLUMINIO – ELEMENTI ALETTATI PER AUMENTARE SCAMBIO TERMICO ED EVACQUAZIONE FUMI – BRUCIATORE CENTRALE DATI – 25 KW : 2 ELEMENTI – 35 KW : 3 ELEMENTI Service ALETTE DI SCAMBIO TERMICO E CONVOGLIAMENTO FUMI BRUCIATORE INGRESSO ACQUA ALETTE DI SCAMBIO TERMICO Rinnova Cond. - Idraulica SCAMBIATORE CONDENSANTE Service PRINCIPIO DI FUNZIONAMENTO: I FUMI SONO CONVOGLIATI AD ALTA VELOCITA’ VERSO L’ALTO ATTRAVERSO I CANALI CREATI DALLE ALETTE SUPERIORI. 2. I FUMI POI SONO POI SPINTI VERSO IL BASSO ED IN QUESTO PERCORSO CEDONO IL LORO CALORE ALL’ACQUA CHE CIRCOLA NEL SENSO OPPOSTO 3. PER FORZA DI GRAVITA LA CONDENSA CHE SI CREA ALL’INTERNO DELLO SCAMBIATORE SCENDE VERSO IL BASSO E PASSA NEL SIFONE. ACQUA 1. PERCORSO ACQUA USCITA FUMI PERCORSO FUMI PROFILO GUIDA FUMI (PERMETTE AI FUMI DI ANDARE SOLO VERSO L’ALTO) SCARICO CONDENSA Rinnova Cond. - Idraulica SCAMBIATORE CONDENSANTE Service CARATTERISTICHE • LE DIMENSIONI ED IL NUMERO DELLE ALETTE PERMETTE A QUESTO SCAMBIATORE DI AVERE UN OTTIMO SCAMBIO TERMICO GRAZIE ALL’ELEVATA SUPERFICIE DI SCAMBIO • I PASSAGGI NEL LATO FUMI SONO MOLTO RISTRETTI PER AUMENTARE LA VELOCITA’ DEI FUMI STESSI • ACQUA E FUMI SEGUONO UN PERCORSO IN CONTRCORRENTE: L’ACQUA FREDDA SCAMBIA CON I FUMI NEL PUNTO PIU’ BASSO IN MODO DA FAVORIRE LA CONDENSAZIONE Rinnova Cond. - Idraulica SCAMBIATORE CONDENSANTE Service PROCEDURA PULIZIA: 1. SPRUZZARE LIQUIDO DI PULIZIA, SIA SU “FONDO SCAMBIATORE CONDNESANTE”, SIA ALL’INTERNO APERTURA BRUCITAORE; 2. LASCIARE CHE IL LIQUIDO SCENDA ALL’INTERNO DEI CANALI, E SVOLGA L’AZIONE DISNICROSTANTE; 3. RISCIAQUARE CON ACQUA, FACENDO DEFLUIRE ACQUA DA FONDO SCAMBIATORE A USCITA BRUCIATORE Rinnova Cond. - Idraulica SCAMBIATORE CONDENSANTE Service PROCEDURA PULIZIA: 1. SVITARE GLI 8 DADI CERCHIATI IN FIGURA; 2. RIMUOVERE BACINELLA IN MATERIALE PLASTICO 3. SMONTARE GRUPPO CONDENSANTE DA CALDAIA; 4. A QUESTO PUNTO SI ACCEDE AI CANALI FUMI Rinnova Cond. - Idraulica SCAMBIATORE CONDENSANTE Service PROCEDURA PULIZIA: 1. RIMONTARE BACINELLA VERIFICANDO INTEGRITA’ DELLA GUARNIZIONE (DOPO ALCUNI ANNI DI FUNZIONAMENTO MOLTO PROBABILMENTE LA GUARNIZIONE ANDRA’ SOSTITUITA) 2. RIMONTARE GRUPPO CONDENSANTE IN CALDAIA Rinnova Cond. - Idraulica GRUPPO ACQUA • Service GRUPPO ACQUA IN PLASTICA – BREVETTO BSG – OLTRE 20 ANNI DI ESPERIENZA SUI MATERIALI PLASTICI – ALTE TEMPERATURA DI LAVORO (130°C) – DI FACILE ACCESSO E SEMPLICE MANUTENZIONE – STESSE CONNESSIONI IDRAULICHE DEI MODELLI PRECEDENTI Rinnova Cond. - Idraulica GRUPPO DI MANDATA RISC+SAN • • CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – VALVOLA TRE VIE – PRESSOSTATO PRIMARIO – BY-PASS – NTC SANITARIO Service PRESSOSTATO CIRCUITO PRIAMRIO NTC ACS BY PASS USCITA ACS MANDATA RISCALDAMENTO OTTURATORE 3 VIE M0OTORE 3 VIE Rinnova Cond. - Idraulica GRUPPO DI MANDATA SV • • CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – VALVOLA TRE VIE – PRESSOSTATO PRIMARIO – BY-PASS MANDATA RISCALDAMENTO Service BY PASS PRESSOSTATO CIRCUITO PRIMARIO MANDATA SERPENTINO BOLLITORE OTTURATORE 3 VIE MOTORE 3 VIE Rinnova Cond. - Idraulica VALVOLA TRE VIE • COMPITO – MODIFICARE IL CIRCUITO PRIMARIO IN RELAZIONE AL TIPO DI RICHIESTA (RISCALDAMENTO, SANITARIO/ANTIGELO) • CARATTERISTICHE – COMPOSTO DA: • NUOVO MOTORE (PISTONCINO CON CORSA PIU’ LUNGA) 220 V, 9,35 KOHM • NUOVO OTTURATORE (SENZA MOTORE POSIZIONATO IN RISCALDAMENTO) – POSIZIONE MOTORE A RIPOSO: SANITARIO Service Rinnova Cond. - Idraulica MOTORE VALVOLA 3 VIE Service • TENSIONE AL MOTORE 3 VIE CON GRUPPO IN OTTONE SANITARIO RISCALDAMENTO • TENSIONE AL MOTORE 3 VIE CON NUOVO GRUPPO IN MATERIALE COMPOSITO SANITARIO RISCALDAMENTO Rinnova Cond. - Idraulica PRESSOSTATO RISCALDAMENTO (ASSOLUTO) • COMPITO – VERIFICARE SOLO PRESENZA ACQUA NEL CIRCUITO PRIMARIO NON VERIFICA LA CIRCOLAZIONE • CARATTERISTICHE – PRESSIONE DI INTERVENTO MIN. 0,35 mbar (ABBINABILE AD IMPIANTI A VASO APERTO) – COLLEGAMENTO A 2 FILI (COM-NO) – 24 Vdc – DIGNOSTICA SPECIFICA (E04 INDICA SOLO SCARSA PRESSIONE E NON LA MANCATA CIRCOLAZIONE ACQUA) Service Rinnova Cond. - Idraulica BY PASS • • Service COMPITO – GARANTISCE UNA MINIMA PORTATA ALLO SCAMBIATORE PRIMARIO A PRESCINDERE DALLE CONDIZIONI IDRAULICHE DELL’IMPIANTO CARATTERISTICHE – AUTOMATICO E NON TARABILE – UNICO MODELLO PER LE VARIE POTENZE NTC SANITARIO • • COMPITO – VERIFICA TEMPERATURA ACS CARATTERISTICHE – 5 V DCV – TENUTA IDRAULICA CON OR + FORCINA – IN CASO DI GUASTO TUTTE LE FUNZIONI DELL’APPARECCHIO SONO ATTIVE Rinnova Cond. - Idraulica NTC RISCALDAMENTO • • Service COMPITO – MONITORARE LA TEMPERATURA DEL CIRCUITO PRIMARIO PER: • GESTIRE LA MODULAZIONE IN BASE ALLA TEMPERATURA RAGGIUNTA • VERIFICARE LA CIRCOLAZIONE ACQUA PRIMARIA ATTRAVERSO LA VELOCITA DI VARIAZIONE DELLA TEMPERATURA CARATTERISTICHE – INSTALLATO SUL TUBO D’ USCITA DALLO SCAMBIATORE PRIMARIO – STESSO BETA DEGLI ALTRI NTC – PER QUALSIASI GUASTO A QUESTA SONDA IL BRUCIATORE NON SI ACCENDE PER NESSUNA RICHIESTA Rinnova Cond. - Idraulica GRUPPO DI RITORNO • • Service CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – FLUSSOSTATO SANITARIO – RUBINETTO DI CARICO – VALVOLA 3 bar – RUBINETTI DI SCARICO Rinnova Cond. - Idraulica GRUPPO DI RITORNO • • CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – FLUSSOSTATO SANITARIO – RUBINETTO DI CARICO – VALVOLA 3 bar – RUBINETTI DI SCARICO Service RUBINETTO DI SCARICO RUBINETTO DI CARICO FLUSSOSTATO SANITARIO ENTRATA SANITARIO RITORNO RISCALDAMENTO Rinnova Cond. - Idraulica ALTRI COMPONENTI • • Service MANOMETRO – INDICATA PRESSIONE DEL CIRCUITO PRIMARIO – LA TEMPERATURA VIENE VISUALIZZATA DA DISPLAY – POSIZIONATO SUL FONDO DELLA CALDAIA FRONTALE CALDAIA VALVOLA DI SICUREZZA (3 BAR) – APRE IL CIRCUITO PRIMARIO IN CASO DI SOVRAPRESSIONI – PRESSIONE DI SCARICO 3 bar – CONNESSIONE 1/2”. IDROMETRO SCARICO VALVOLA DI SICUREZZA Rinnova Cond. - Idraulica FLUSSOSTATO SANITARIO E RUBINETTO RIEMPIMENTO Service FLUSSOSTATO SANITARIO • COMPITO – AVVERTIRE RICHIESTA SANITARIO • CARATTERISTICHE – FLUSSOSTATO SANITARIO MAGNETICO – BASSA TENSIONE DI SICUREZZA – PORTATA MINIMA: 2,5 l/min – PRESSIONE MINIMA 0,3 bar RUBINETTO RIEMPIMENTO • COMPITO – METTE IN COMUNICAZIONE IL CIRCUITO PRIMARIO CON QUELLO SANITARIO PER PERMETTERE IL CARICO IMPIANTO • CARATTERISTICHE – ACCESSIBILE COMODAMENTE – DI SEMPLICE MANUTENZIONABILITA’ Rinnova Cond. - Idraulica SCAMBIATORE SANITARIO Service COMPITO • PRODURRE ACQUA CALDA SANITARIA ATTRAVERSO UNO SCAMBIO TERMICO ACQUA ACQUA CARATTERISTICHE • REALIZZATO CON PIASTRE IN ACCIAIO • GEOMETRIA A NIDO D’APE • SUPERFICI DI SCAMBIO PER GARANTIRE ELEVATA EFFICIENZA • FLUSSI DEI CIRCUITI IN CONTROCORRENTE MODELLO 25 S 35 S N° PIASTRE 12 14 PORTATA l/min DT 25° 14 20 Rinnova Cond. - Idraulica