Service
Inovia Cond HT
CIRCUITO GAS
VALVOLA GAS PREMIX
Service
MODELLO:
• SIT 848 SIGMA
CARATTERISTICHE:
•TEMPERATURE DI ESERCIZIO -10°/+ 60°C;
•RAPPORTO ARIA GAS 1:1
•TENSIONE DI ALIMENTAZIONE 230 V.c.a.
• VITE DI REGOLAZIONE MINA TARATURA TRAMITE VITE A
BRUGOLA;
•VITE TARATURA DEL MASSIMO;
•PRESA DI COMPENSAZIONE
•VALVOLA COMPATIBILE CON MODELLI M160 E MODELLI
INOVIA COND.
•OPERATORE DISPONIBILE COME RICAMBIO
REG. MAX
REG. MIN
Inovia Cond. HT CIRCUITO GAS
DIAFRAMMA GAS
•
Service
COMPITO
– RIDURRE LA MASSIMA PORTATA DI GAS AL
BRUCIATORE
•
CARATTERISTICHE
– ANELLO IN OTTONE CON FORI CALIBRATI IN BASE
AL TIPO DI GAS E POTENZA CALDAIA
– DIAFRAMMI NON COMPATIBILI CON INOVIA COND.
METANO
GPL
16 SV
460
360
25 SV
460
360
35 SV
530
410
25 S
460
360
35 S
530
410
Inovia Cond. HT CIRCUITO GAS
VENTILATORE
•
COMPITO
– INVIARE AL BRUCIATORE LA MISCELA
ARIA/GAS
– EVACUARE I PRODOTTI DELLA
COMBUSTIONE
– MODULARE LA POTENZA DEL BRUCIATORE
VARIANDO IL N° DI GIRI.
•
CARATTERISTICHE
– COSTRUTTORE: NATALINI
– MODELLO LN2 NG40
– ASSORBIMENTO:
– 2 MODELLI IN FUNZIONE DELLA POTENZA;
– MIXER INCORPORATO NEL VENTILATORE
– COLLEGATO CON 2 CABLAGGI, UNO DI
POTENZA 230 V.c.a. E UNO DI SEGNALE A
24V.c.c.
Service
Inovia Cond. HT CIRCUITO GAS
MANICHETTA - BRUCIATORE
•
COMPITO
– PROGETTATO PER OTTIMIZZARE LA
COMBUSTIONE A PREMISCELAZIONE
CHE VIENE EFFETTUATA DAL SISTEMA
VENTILATORE-VALVOLA GAS
•
CARATTERISTICHE
– BRUCIATORE ECOLOGICO IN ACCIAIO
INOX AISI;
– MANICHETTA FRONTALE RAFREDDATA
– RIDOTTE EMISSIONI INQUINANTI DI Nox
(CALDAIA CLASSE 5 NOX)
– FACILMENTE ESTRAIBILE DAL
FRONTALE
– DUE ELETTRODI MONTATI: UNO DI
SCARICA E UNO DI IONIZZAZIONE
– PREGETTATO PER G20 G30 G31
– COME RICAMBIO VIENE GESTITO UN
UNICO OMPONENTE COMPLETO DI
BRUCIATORE E MANICHETTA.
Service
Inovia Cond. HT CIRCUITO GAS
SICUREZZE TERMICHE
•
•
Service
COMPITO
– EVITA SOVRATEMPERATURE IN CALDAIA O SU LATO FUMI
CARATTERISTICHE
– TERMOSATATO MASSIMA TEMPERATURA
– TEMPERATURA DI INTERVENTO 103 °C, RIARMO
AUTOMATICO
– IN CASO DI INTERVENTO IL DISPLAY VISUALIZZA E02
– SONDA FUMI F1 :
– PRESERVA I CONDOTTI DI ESPULSIONE
– CON LA TEMPERATURA FUMI TRA I 110° C E I 120°C
VIENE FORZATA LA MODULAZIONE
– OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA LED TERMOFUSIBILE F2
SEGNALANO LIMITAZIONE TEMPERATURA SONDA
SCARICO FUMI (E10)
– TERMOFUSIBILE F2:
– L’INTERVENTO DI F2 INDICA UNO SCARSO SCAMBIO
TERMICO
– SE LA TEMPERATURA FUMI, PRIMA DI PASSARE PER
LO SCAMBIATORE CONDENSANTE, SUPERA I 140°
BLOCCA IMMEDIATAMENTE IL BRUCIATORE
INTERROMPENDO LA SONDA FUMI (E09)
SONDA FUMI F1
Inovia Cond. HT CIRCUITO GAS
SIFONE SCARICO CONDENSA
•
•
Service
COMPITO
– CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO
DEL GRUPPO CONDENSANTE
– EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO
CONDENSA
CARATTERISTICHE
– DIAMETRO RACCORDO COLLEGAMENTO: 25 mm.
– TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE
PLASTICO L= 45 cm
– PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL
CASO IL SIFONE SI ASCIUGHI
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
COME PER TUTTE LE CALDAIE A
CONDENSAZIONE PREMISCELATE
LE TARATURE DEL GAS SI
ESEGUONO SOLO CON L’UTILIZZO
DELL’ANALIZZATORE
DI
COMBUSTIONE
SEGUENDO LA
PROCEDURA SOTTO INDICATA.
ATTIVAZIONE SPAZZACAMINO
1. ENTRARE IN MODALITA’ SPAZZACAMINO
SEGUENDO LE IDICAZIONI SOTTO RIPORTATE:
 CHIUDERE IL CONTATTO TA
 TENERE PREMUTO I PULSANTI A+B+D
IN FIGURA (CIRCA 10 sec): IL DISPLAY
INDICHERA’ P01 CON IL RELATIVO
VALORE IMPOSTATO
 PREMERE CONTEMPORANEAMENTE I
TASTI A e B ; IL DISPLAY INDICHERA’
LP + SIMBOLO SPAZZACAMINO
(FUNZIONE SPAZZACAMINO ATTIVA)
A+B
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE MINIMO GAS
1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI PAGINA
PRECEDENTE)
2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL
DISPLAY DA’ LA INDICAZIONE LP RIPORTATA IN
FIGURA, OVVERO ATTIVAZIONE DELLA FUNZIONE
SPAZZACAMINO MINIMA POTENZA, ALTERNATA AL
VALORE DELLA TEMPERATUTRA DI MANDATA)
3. PREMERE IL TASTO A IL DISPLAY INDICA HP ( MINIMO
RISCALDAMENTO)
4. AVVIARE ANALIZZATORE DI COMBUSTIONE
5. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO
RIPORTATO NEL LIBRETTO A CORREDO DELLA
CALDAIA
6. AGIRE SULLA VITE INICATA IN FIGURA PER
MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA
(AVVITANDO CO2 AUMENTA)
REG. MINIMO
GAS
NB
LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO DI
¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2
LETTO SULLO STRUMENTO RIMANGA COSTANTE
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REG. MINIMO
GAS RISC.
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE MASSIMO GAS
1. PREMERE DIVERSE VOLTE IL TASTO A FINO A
CHE IL DISPLAY INDICA DP ALTERNATO AL VALORE
DELLA TEMPERATURA DI MANDATA (FUNZIONE
FORZATURA MASSIMA POTENZA ATTIVATA)
2. CONFRONTARE IL VALORE DI CO2 LETTO CON
QUELLO RIPORTATO NEL LIBRETTO A CORREDO
DELLA CALDAIA.
3. AGIRE SULLA VITE INDICATA IN FIGURA PER
MODIFCARE IL VALORE DI CO2 ALLA MASSIMA
POTENZA (AVVITANDO CO2 DIMINUISCE)
REGOLAZIONE
MASSIMO GAS
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
Questi valori vanno verificati
in occasione della taratura valvola gas
REGOLAZIONE
MASSIMO GAS
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE MINIMO GAS
1. UNA VOLTA COMPLETATA LA TARATURA ALLA MASSIMA
POTENZA DP
2. PREMERE IL TASTO B FINO AQUANDO SUL DISPLAY
COOMPARE LP (IL DISPLAY DA’ L’INDICAZIONE LP
RIPORTATA IN FIGURA, OVVERO ATTIVAZIONE DELLA
FUNZIONE SPAZZACAMINO MINIMA POTENZA
SANITARIA, ALTERNATA AL VALORE DELLA
TEMPERATUTRA DI MANDATA)
3. AVVIARE L’ANALIZZATORE DI COMBUSTIONE
4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO
RIPORTATO NEL LIBRETTO A CORREDO DELLA
CALDAIA
5. AGIRE SULLA VITE INICATA IN FIGURA PER
MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA
(AVVITANDO CO2 AUMENTA)
REG. MINIMO
GAS
NB
LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO DI
¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2
LETTO SULLO STRUMENTO RIMANGA COSTANTE
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REG. MINIMO
GAS
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE MASSIMO GAS
1. PREMERE DIVERSE VOLTE IL TASTO A FINO A
CHE IL DISPLAY INDICA CP ALTERNATO AL VALORE
DELLA TEMPERATURA DI MANDATA (FUNZIONE
FORZATURA MASSIMA POTENZA ATTIVATA)
2. CONFRONTARE IL VALORE DI CO2 LETTO CON
QUELLO RIPORTATO NEL LIBRETTO A CORREDO
DELLA CALDAIA.
3. AGIRE SULLA VITE INDICATA IN FIGURA PER
MODIFCARE IL VALORE DI CO2 ALLA MASSIMA
POTENZA (AVVITANDO CO2 DIMINUISCE)
REGOLAZIONE
MASSIMO GAS
Inovia Cond. HT CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE
MASSIMO GAS
Questi valori vanno verificati
in occasione della verifica di combustione
Inovia Cond. HT CIRCUITO GAS
Scarica