Service
Inovia Cond MAX
CIRCUITO GAS
SCHEMA CIRCUITO GAS
Service
SCAMBIATORE
BRUCIATORE
VENTILATORE
DIAFRAMMA
VALVOLA GAS
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
VALVOLA GAS PREMIX
Service
MODELLO:
•SIT 848 SIGMA
•POSSIBILITA’ DI TARATURA DELLA MASSIMA QUANTITA’ DI
GAS GRAZIE A INSERIMENTO VITE DI REGOLAZIONE
MASSIMO GAS;
•PRESA DI COMPENSAZIONE;
CARATTERISTICHE:
•AGENDO IN SENSO ORAIO SULLA VITE SI PUO’ VARIARE IL
VALORE CO2 ALLA MASSIMA POTENZA
REG. MAX
REG. MIN
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
DIAFRAMMA GAS
•
Service
COMPITO
– RIDURRE LA MASSIMA PORTATA DI GAS AL
BRUCIATORE
•
CARATTERISTICHE
– ANELLO IN OTTONE CON FORI CALIBRATI IN BASE
AL TIPO DI GAS E POTENZA CALDAIA
– DIAFRAMMI COMPATIBILI CON INOVIA COND HT,
SOLO NELLA VERSIONE METANO
METANO
GPL
25 S
460
360
35 S
540
420
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
VENTILATORE
•
Service
COMPITO
– INVIARE AL BRUCIATORE LA MISCELA ARIA/GAS
– EVACUARE I PRODOTTI DELLA COMBUSTIONE
– MODULARE LA POTENZA DEL BRUCIATORE
VARIANDO IL N° DI GIRI.
•
CARATTERISTICHE
–
–
–
–
–
–
COSTRUTTORE: NATALINI
MODELLO LN2 NG40
ASSORBIMENTO:
2 MODELLI IN FUNZIONE DELLA POTENZA;
MIXER INCORPORATO NEL VENTILATORE
COLLEGATO CON 2 CABLAGGI, UNO DI POTENZA
230 V.c.a. E UNO DI SEGNALE A 24V.c.c.
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
BRUCIATORE
•
COMPITO
– PROGETTATO PER OTTIMIZZARE LA
COMBUSTIONE A PREMISCELAZIONE
CHE VIENE EFFETTUATA DAL SISTEMA
VENTILATORE-VALVOLA GAS
•
CARATTERISTICHE
– BRUCIATORE ECOLOGICO IN ACCIAIO
INOX AISI
– RIDOTTE EMISSIONI INQUINANTI DI Nox
(CALDAIA CLASSE 5 NOX)
– FACILMENTE ESTRAIBILE DAL
FRONTALE
– DUE ELETTRODI MONTATI: UNO DI
SCARICA E UNO DI IONIZZAZIONE
– PREGETTATO PER G20 G30 G31
Service
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
SICUREZZE TERMICHE
•
•
Service
COMPITO
– EVITA SOVRATEMPERATURE IN CALDAIA O SU LATO
FUMI
CARATTERISTICHE
– TERMOSATATO MASSIMA TEMPERATURA
– TEMPERATURA DI INTERVENTO 103 °C, RIARMO
AUTOMATICO
– IN CASO DI INTERVENTO IL DISPLAY VISUALIZZA E02
– SONDA FUMI F1 :
– PRESERVA I CONDOTTI DI ESPULSIONE
– CON LA TEMPERATURA FUMI TRA I 110° C E I 120°C
VIENE FORZATA LA MODULAZIONE
TERMOFUSIBILE F2
– OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA LED
SEGNALANO LIMITAZIONE TEMPERATURA SONDA
SCARICO FUMI (E10)
– TERMOFUSIBILE F2:
– L’INTERVENTO DI F2 INDICA UNO SCARSO SCAMBIO
TERMICO
– SE LA TEMPERATURA FUMI, PRIMA DI PASSARE PER
LO SCAMBIATORE CONDENSANTE, SUPERA I 140°
BLOCCA IMMEDIATAMENTE IL BRUCIATORE
INTERROMPENDO LA SONDA FUMI (E09)
SONDA FUMI F1
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
SIFONE SCARICO CONDENSA
•
•
Service
COMPITO
– CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO
DEL GRUPPO CONDENSANTE
– EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO
CONDENSA
CARATTERISTICHE
– DIAMETRO RACCORDO COLLEGAMENTO: 25 mm.
– TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE
PLASTICO L= 45 cm
– PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL
CASO IL SIFONE SI ASCIUGHI
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
TARATURA VALVOLA GAS
Service
COME PER TUTTE LE CALDAIE A
CONDENSAZIONE PREMISCELATE
LE TARATURE DEL GAS SI
ESEGUONO SOLO CON L’UTILIZZO
DELL’ANALIZZATORE
DI
COMBUSTIONE E SEGUENDO LA
PROCEDURA SOTTO INDICATA.
ATTIVAZIONE SPAZZACAMINO
• ENTRARE IN MODALITA’ SPAZZACAMINO
SEGUENDO LE IDICAZIONI SOTTO
RIPORTATE:
– CHIUDERE IL CONTATTO TA
– TENERE PREMUTO I PULSANTI A+B+D IN
FIGURA (CIRCA 10 sec): IL DISPLAY
INDICHERA’ P01 CON IL RELATIVO VALORE
IMPOSTATO
– PREMERE CONTEMPORANEAMENTE I
TASTI A e B ; IL DISPLAY INDICHERA’
LP + SIMBOLO SPAZZACAMINO (FUNZIONE
SPAZZACAMINO ATTIVA)
A+B
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
TARATURA VALVOLA GAS
Service
REGOLAZIONE MINIMO GAS
1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI PAGINA
PRECEDENTE)
2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL
DISPLAY DA’ LA INDICAZIONE LP OVVERO ATTIVAZIONE
DELLA FUNZIONE SPAZZACAMINO MINIMA POTENZA,
ALTERNATA AL VALORE DELLA TEMPERATUTRA DI
MANDATA)
3. AVVIARE ANALIZZATORE DI COMBUSTIONE
4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO
RIPORTATO NEL LIBRETTO A CORREDO DELLA
CALDAIA (8,7% - 9,3%)
5. AGIRE SULLA VITE INICATA IN FIGURA PER
MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA
(AVVITANDO CO2 AUMENTA)
REG. MINIMO
GAS
NB
LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO DI
¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2
LETTO SULLO STRUMENTO RIMANGA COSTANTE
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
TARATURA VALVOLA GAS
Service
REGOLAZIONE MASSIMO GAS
1. PREMERE DIVERSE VOLTE I TASTI A O B FINO A
CHE IL DISPLAY NON INDICA DP ALTERNATO AL
VALORE DELLA TEMPERATURA DI MANDATA
(FUNZIONE FORZATURA MASSIMA POTENZA
ATTIVATA)
2. CONFRONTARE IL VALORE DI CO2 LETTO CON
QUELLO RIPORTATO NEL LIBRETTO A CORREDO
DELLA CALDAIA (ES. METANO 9,3% – 9,9%)
3. AGIRE SULLA VITE INDICATA IN FIGURA PER
MODIFCARE IL VALORE DI CO2 ALLA MASSIMA
POTENZA (AVVITANDO CO2 DIMINUISCE)
REGOLAZIONE
MASSIMO GAS
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
TRASFORMAZIONE GAS
Service
TOGLIERE LA FORCINA “A”
SVITARE IL GIRELLO “C”
TOGLIERE IL TUBO “B”
ESEGUIRE LA TRASFORMAZIONE DEL TIPO DI GAS
SOSTITUENDO CORRETTAMENTE IL DIAFRAMMA GAS
METANO
GPL
25 S
450
345
35 S
540
420
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
TRASFORMAZIONE GAS
Service
ENTRARE IN MODALITA’ PROGRAMMAZIONE
SCORRERE I PARAMETRI FINO A FARE APPARIRE SUL DISPLAY LCD LE LETTERE P05
MODIFICARE IL VALORE DEL PARAMETRO “5” A SECONDA DEL TIPO DI GAS
CONFERMARE LA MODIFICA PREMENDO IL TASTO
EFFETTUARE LE TARATURE DELLA VALVOLA GAS
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS
Scarica

M262-GAS