Service Inovia Cond MAX CIRCUITO GAS SCHEMA CIRCUITO GAS Service SCAMBIATORE BRUCIATORE VENTILATORE DIAFRAMMA VALVOLA GAS RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS VALVOLA GAS PREMIX Service MODELLO: •SIT 848 SIGMA •POSSIBILITA’ DI TARATURA DELLA MASSIMA QUANTITA’ DI GAS GRAZIE A INSERIMENTO VITE DI REGOLAZIONE MASSIMO GAS; •PRESA DI COMPENSAZIONE; CARATTERISTICHE: •AGENDO IN SENSO ORAIO SULLA VITE SI PUO’ VARIARE IL VALORE CO2 ALLA MASSIMA POTENZA REG. MAX REG. MIN RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS DIAFRAMMA GAS • Service COMPITO – RIDURRE LA MASSIMA PORTATA DI GAS AL BRUCIATORE • CARATTERISTICHE – ANELLO IN OTTONE CON FORI CALIBRATI IN BASE AL TIPO DI GAS E POTENZA CALDAIA – DIAFRAMMI COMPATIBILI CON INOVIA COND HT, SOLO NELLA VERSIONE METANO METANO GPL 25 S 460 360 35 S 540 420 RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS VENTILATORE • Service COMPITO – INVIARE AL BRUCIATORE LA MISCELA ARIA/GAS – EVACUARE I PRODOTTI DELLA COMBUSTIONE – MODULARE LA POTENZA DEL BRUCIATORE VARIANDO IL N° DI GIRI. • CARATTERISTICHE – – – – – – COSTRUTTORE: NATALINI MODELLO LN2 NG40 ASSORBIMENTO: 2 MODELLI IN FUNZIONE DELLA POTENZA; MIXER INCORPORATO NEL VENTILATORE COLLEGATO CON 2 CABLAGGI, UNO DI POTENZA 230 V.c.a. E UNO DI SEGNALE A 24V.c.c. RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS BRUCIATORE • COMPITO – PROGETTATO PER OTTIMIZZARE LA COMBUSTIONE A PREMISCELAZIONE CHE VIENE EFFETTUATA DAL SISTEMA VENTILATORE-VALVOLA GAS • CARATTERISTICHE – BRUCIATORE ECOLOGICO IN ACCIAIO INOX AISI – RIDOTTE EMISSIONI INQUINANTI DI Nox (CALDAIA CLASSE 5 NOX) – FACILMENTE ESTRAIBILE DAL FRONTALE – DUE ELETTRODI MONTATI: UNO DI SCARICA E UNO DI IONIZZAZIONE – PREGETTATO PER G20 G30 G31 Service RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS SICUREZZE TERMICHE • • Service COMPITO – EVITA SOVRATEMPERATURE IN CALDAIA O SU LATO FUMI CARATTERISTICHE – TERMOSATATO MASSIMA TEMPERATURA – TEMPERATURA DI INTERVENTO 103 °C, RIARMO AUTOMATICO – IN CASO DI INTERVENTO IL DISPLAY VISUALIZZA E02 – SONDA FUMI F1 : – PRESERVA I CONDOTTI DI ESPULSIONE – CON LA TEMPERATURA FUMI TRA I 110° C E I 120°C VIENE FORZATA LA MODULAZIONE TERMOFUSIBILE F2 – OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA LED SEGNALANO LIMITAZIONE TEMPERATURA SONDA SCARICO FUMI (E10) – TERMOFUSIBILE F2: – L’INTERVENTO DI F2 INDICA UNO SCARSO SCAMBIO TERMICO – SE LA TEMPERATURA FUMI, PRIMA DI PASSARE PER LO SCAMBIATORE CONDENSANTE, SUPERA I 140° BLOCCA IMMEDIATAMENTE IL BRUCIATORE INTERROMPENDO LA SONDA FUMI (E09) SONDA FUMI F1 RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS SIFONE SCARICO CONDENSA • • Service COMPITO – CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO DEL GRUPPO CONDENSANTE – EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO CONDENSA CARATTERISTICHE – DIAMETRO RACCORDO COLLEGAMENTO: 25 mm. – TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE PLASTICO L= 45 cm – PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL CASO IL SIFONE SI ASCIUGHI RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS TARATURA VALVOLA GAS Service COME PER TUTTE LE CALDAIE A CONDENSAZIONE PREMISCELATE LE TARATURE DEL GAS SI ESEGUONO SOLO CON L’UTILIZZO DELL’ANALIZZATORE DI COMBUSTIONE E SEGUENDO LA PROCEDURA SOTTO INDICATA. ATTIVAZIONE SPAZZACAMINO • ENTRARE IN MODALITA’ SPAZZACAMINO SEGUENDO LE IDICAZIONI SOTTO RIPORTATE: – CHIUDERE IL CONTATTO TA – TENERE PREMUTO I PULSANTI A+B+D IN FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’ P01 CON IL RELATIVO VALORE IMPOSTATO – PREMERE CONTEMPORANEAMENTE I TASTI A e B ; IL DISPLAY INDICHERA’ LP + SIMBOLO SPAZZACAMINO (FUNZIONE SPAZZACAMINO ATTIVA) A+B RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS TARATURA VALVOLA GAS Service REGOLAZIONE MINIMO GAS 1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI PAGINA PRECEDENTE) 2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL DISPLAY DA’ LA INDICAZIONE LP OVVERO ATTIVAZIONE DELLA FUNZIONE SPAZZACAMINO MINIMA POTENZA, ALTERNATA AL VALORE DELLA TEMPERATUTRA DI MANDATA) 3. AVVIARE ANALIZZATORE DI COMBUSTIONE 4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (8,7% - 9,3%) 5. AGIRE SULLA VITE INICATA IN FIGURA PER MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA (AVVITANDO CO2 AUMENTA) REG. MINIMO GAS NB LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO DI ¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2 LETTO SULLO STRUMENTO RIMANGA COSTANTE RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS TARATURA VALVOLA GAS Service REGOLAZIONE MASSIMO GAS 1. PREMERE DIVERSE VOLTE I TASTI A O B FINO A CHE IL DISPLAY NON INDICA DP ALTERNATO AL VALORE DELLA TEMPERATURA DI MANDATA (FUNZIONE FORZATURA MASSIMA POTENZA ATTIVATA) 2. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (ES. METANO 9,3% – 9,9%) 3. AGIRE SULLA VITE INDICATA IN FIGURA PER MODIFCARE IL VALORE DI CO2 ALLA MASSIMA POTENZA (AVVITANDO CO2 DIMINUISCE) REGOLAZIONE MASSIMO GAS RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS TRASFORMAZIONE GAS Service TOGLIERE LA FORCINA “A” SVITARE IL GIRELLO “C” TOGLIERE IL TUBO “B” ESEGUIRE LA TRASFORMAZIONE DEL TIPO DI GAS SOSTITUENDO CORRETTAMENTE IL DIAFRAMMA GAS METANO GPL 25 S 450 345 35 S 540 420 RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS TRASFORMAZIONE GAS Service ENTRARE IN MODALITA’ PROGRAMMAZIONE SCORRERE I PARAMETRI FINO A FARE APPARIRE SUL DISPLAY LCD LE LETTERE P05 MODIFICARE IL VALORE DEL PARAMETRO “5” A SECONDA DEL TIPO DI GAS CONFERMARE LA MODIFICA PREMENDO IL TASTO EFFETTUARE LE TARATURE DELLA VALVOLA GAS RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GAS