Service
RinNOVA SOLAR TANK
CIRCUITO GAS
CIRCUITO GAS
Service
BRUCIATORE
VENTILATORE
DIAFRAMMI GAS
VALVOLA GAS
RinNOVA SOLAR TANK – CIRCUITO GAS
VALVOLA GAS E DIAFRAMMI
•
Service
•
COMPITO
MASSIMO
– APRIRE/CHIUDERE IL GAS IN BASE ALLE
GAS
RICHIESTE
– CHIUDERE IL GAS IN CASO DI INTERVENTO DELLE
PROTEZIONI
CARATTERISTICHE
MINIMO GAS
– MODELLO SIT 848 SIGMA
– NUOVA MODELLO CON MEMBRANE PIU’ SENSIBILI
CHE MIGLIORANO LA MODULAZIONE
– OPERATORI ON - OFF ALIMENTATI A 220 V
– NON INTERCAMBIABILE CON PARVA CONDENSING
•
DIAFRAMMI
G20
G30/31
25 S
6,20
4,50
35 S
7,70
5,20
25 SV
6,40**
4,60**
30 SV
7,70**
5,20**
** IN ATTESA DI OMOLOGAZIONE
RinNOVA SOLAR TANK – CIRCUITO GAS
MIXER ARIA-GAS
DIAFRAMMA
ARIA
Service
•
FUNZIONE:
• MISCELARE ARIA E GAS IN INGRESSO AL
VENTILATORE
• RIDURRE RUMOROSITA’ IN FASE DI ACCENSIONE
•
CARATTERISTICHE :
• DOTATO DI DIFRAMMA ARIA INTERNO DIVERSO IN
BASE ALLA POTENZA MASSIMA DELLA CALDAIA:
– 25 S - SV (2 ELEMENTI): FUCSIA
– 35 S - SV (3 ELEMENTI): BLU
• IN CASO DI CAMBIO GAS IL MIXER RIMANE LO
STESSO
RinNOVA SOLAR TANK – CIRCUITO GAS
VENTILATORE
Service
•
COMPITO
– INVIARE AL BRUCIATORE LA
MISCELA ARIA/GAS
– EVACUARE I PRODOTTI DELLA
COMBUSTIONE
– MODULARE LA POTENZA DEL
BRUCIATORE VARIANDO IL N° DI
GIRI.
•
CARATTERISTICHE
– MODELLO: EBM MRG118
– ALIMENTAZIONE ELETTRCA: 230V
ca
– POTENZA 60 W
– COLLEGATO CON 2 CABLAGGI
UNO DI POTENZA E UNO DI
SEGNALE
ALIMENTAZIONE 230 V
SEGNALE CONTROLLO
NUMERO DI GIRI
RinNOVA SOLAR TANK – CIRCUITO GAS
BRUCIATORE ED ELETTRODI
•
•
Service
COMPITO
– PROGETTATO PER OTTIMIZZARE LA
COMBUSTIONE A
PREMISCELAZIONE CHE VIENE
EFFETTUATA DAL SISTEMA
VENTILATORE-VALVOLA GAS
CARATTERISTICHE
– BRUCIATORE ECOLOGICO IN
ACCIAIO INOX AISI 316L
– RIDOTTE EMISSIONI INQUINANTI DI
Nox (CALDAIA CLASSE 5 NOX)
– FACILMENTE ESTRAIBILE DAL
FRONTALE
– DUE MODELLI 24/32 KW
– DUE ELETTRODI MONTATI: UNO DI
SCARICA E UNO DI IONIZZAZIONE
RinNOVA SOLAR TANK – CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
COME PER TUTTE LE CALDAIE A
CONDENSAZIONE
PREMISCELATE
LE
TARATURE DEL GAS SI ESEGUONO SOLO
CON L’UTILIZZO DELL’ANALIZZATORE DI
COMBUSTIONE
E
SEGUENDO
LA
PROCEDURA SOTTO INDICATA.
ATTIVAZIONE SPAZZACAMINO
1. ENTRARE IN MODALITA’ SPAZZACAMINO
SEGUENDO LE IDICAZIONI SOTTO RIPORTATE:
 CHIUDERE IL CONTATTO TA
 TENERE PREMUTO I PULSANTI A+B+D
IN FIGURA (CIRCA 10 sec): IL DISPLAY
INDICHERA’ P01 CON IL RELATIVO
VALORE IMPOSTATO
 PREMERE CONTEMPORANEAMENTE I
TASTI A e B ; IL DISPLAY INDICHERA’
LP + SIMBOLO SPAZZACAMINO
A+B
RinNOVA SOLAR TANK – CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE MINIMO GAS
1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI PAGINA
PRECEDENTE)
2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL
DISPLAY DA’ LA INDICAZIONE LP RIPORTATA IN
FIGURA, OVVERO ATTIVAZIONE DELLA FUNZIONE
SPAZZACAMINO MINIMA POTENZA, ALTERNATA AL
VALORE DELLA TEMPERATUTRA DI MANDATA)
3. AVVIARE ANALIZZATORE DI COMBUSTIONE
4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO
RIPORTATO NEL LIBRETTO A CORREDO DELLA
CALDAIA (8,7% - 9,3%)
5. AGIRE SULLA VITE INICATA IN FIGURA PER
MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA
(AVVITANDO CO2 AUMENTA)
REG. MINIMO
GAS
RinNOVA SOLAR TANK – CIRCUITO GAS
PROCEDURA TARATURA GAS
Service
REGOLAZIONE MASSIMO GAS
1. PREMERE DIVERSE VOLTE I TASTI A O B FINO A
CHE IL DISPLAY NON INDICA DP ALTERNATO AL
VALORE DELLA TEMPERATURA DI MANDATA
(FUNZIONE FORZATURA MASSIMA POTENZA
ATTIVATA)
2. CONFRONTARE IL VALORE DI CO2 LETTO CON
QUELLO RIPORTATO NEL LIBRETTO A CORREDO
DELLA CALDAIA (9,3 – 9,9)
3. AGIRE SULLA VITE INDICATA IN FIGURA PER
MODIFCARE IL VALORE DI CO2 ALLA MASSIMA
POTENZA (AVVITANDO CO2 DIMINUISCE)
REGOLAZIONE
MASSIMO GAS
RinNOVA SOLAR TANK – CIRCUITO GAS
PROCEDURA CAMBIO GAS
Service
SEGUIRE LE ISRUZIONI SOTTO RIPORTATE PER
EFFETTUARE LA TRASFORMAZIONE GAS:
1. SOSTITUIRE IL DIAFRAMMA GAS
2. ENTRARE IN PROGRAMMAZIONE SEGUENDO LE
ISTRUZIONI SOTTO RIPORTATE:
 TENERE PREMUTO I PULSANTI A+B+D IN FIGURA
(CIRCA 10 sec): IL DISPLAY INDICHERA’ P01 CON IL
RELATIVO VALORE IMPOSTATO
 SCORRERE I VARI PARAMETRI CON I TASTI A o B
FINO A CHE IL DISPLAY NON INDICA P05 CON IL
RELATIVO VALORE IMPOSTATO
 CON I TASTI H O G MODIFICARE IL VALORE
P05 = 00 METANO
P05 = 05 GPL
 PREMERE IL TASTO D PER CONFERMARE LA
MODIFICA
 TOGLIERE ALIMENTAZIONE ELETTRICA PER
USCIRE DALLA PROGRAMMAZIONE
3. VERIFICARE LE TARATURE DEL GAS COME
DESCRITTO NELLE PAGINE PRECEDENTI.
RinNOVA SOLAR TANK – CIRCUITO GAS
SICUREZZE TERMICHE
NTC FUMI
• COMPITO
– VERIFICA LA TEMPERATURA FUMI PER
TENERE SOTTO CONTROLLO LO SCAMBIO
TERMICO ED EVITARE DANNI AL CONDOTTO
FUMI
• CARATTERISTICHE
– CON LA TEMP. FUMI TRA 110°-120° C
VIENE
FORZATA LA MODULAZIONE
– OLTRE I 120°C BLOCCO FIAMMA E
DIAGNOSTICA DEDICATA (Er10 + RESET)
– IN CASO DI GUASTO OGNI FUNZIONAMENTO
E’ INIBITO (Er 09 +
)
TERMOSTATO MASSIMA TEMPERATURA
• COMPITO
– BLOCCARE IL FUNZIONAMENTO IN CASO DI
SOVRATEMPERATURE
• CARATTERISTICHE
– INTERVENTO A 105° C, RIARMO AUTOMATICO
– DIAGNOSTICA DEDICATA (Er02 + RESET)
Service
NTC FUMI
TERMOSTATO MASSIMA
TEMPERATURA
RinNOVA SOLAR TANK – CIRCUITO GAS
SIFONE SCARICO CONDENSA
•
•
Service
COMPITO
– CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO
DEL GRUPPO CONDENSANTE
– EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO
CONDENSA
CARATTERISTICHE
– DIAMETRO RACCORDO COLLEGAMENTO: 25 mm.
– TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE
PLASTICO L= 45 cm
– PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL
CASO IL SIFONE SI ASCIUGHI
– VERIFICA SCARICO CONDENSA: NELLA PARTE ALTA DEL
SIFONE E’ COLLEGATO UN TERMINALE DEL CABLAGGIO
DELL’ELETTRODO DI IONIZZAZIONE (PROTETTO DA
CANOTTO). SE IL SIFONE NON SCARICA IL LIVELLO DI
CONDENSA SALE FINO AL LIVELLO DEL CONNETTORE
MANDANDO IN BLOCCO FIAMMA LA CALDAIA.
RinNOVA SOLAR TANK – CIRCUITO GAS
Scarica

Rinnova Cond - gas