Service INOVIA SOLAR TANK CIRCUITO GAS SCHEMA CIRCUITO GAS Service SCAMBIATORE BRUCIATORE VENTILATORE DIAFRAMMA VALVOLA GAS INOVIA SOLAR TANK: CIRCUITO GAS VALVOLA GAS PREMIX Service MODELLO: •SIT 848 SIGMA •POSSIBILITA’ DI TARATURA DELLA MASSIMA QUANTITA’ DI GAS GRAZIE A INSERIMENTO VITE DI REGOLAZIONE MASSIMO GAS; •PRESA DI COMPENSAZIONE; CARATTERISTICHE: •AGENDO IN SENSO ORAIO SULLA VITE SI PUO’ VARIARE IL VALORE CO2 ALLA MASSIMA POTENZA REG. MAX REG. MAX INOVIA SOLAR TANK: CIRCUITO GAS DIAFRAMMA GAS • Service COMPITO – RIDURRE LA MASSIMA PORTATA DI GAS AL BRUCIATORE • CARATTERISTICHE – ANELLO IN OTTONE CON FORI CALIBRATI IN BASE AL TIPO DI GAS E POTENZA CALDAIA METANO GPL 25 SV 565 430 35 SV 690 505 25 S 565 430 35 S 690 505 INOVIA SOLAR TANK: CIRCUITO GAS MIXER ARIA -AERTECH Service COMPITO •MISCELARE L’ARIA CON IL GAS NELLE GIUSTE PROPORZIONI •RIDURRE RUMOROSITA’ BRUCIATORE CARATTERISTICHE •SVILUPPATO PER BRUCIATORE G20 E G30/31 VANTAGGI NUOVO AERTECH •MIGLIORATA LA FACILITA’ DI MANUTENZIONE (tenuta tuboaertech con or + forcina acciaio); •MIGLIORATA SILENZIOSITA’ CALDAIA RESTRICTOR DI MISCELAZIONE ARIA-GAS: 25 KW: COLORE FUCSIA 35 KW: COLORE BLU INOVIA SOLAR TANK: CIRCUITO GAS VENTILATORE Service • COMPITO – INVIARE AL BRUCIATORE LA MISCELA ARIA/GAS – EVACUARE I PRODOTTI DELLA COMBUSTIONE – MODULARE LA POTENZA DEL BRUCIATORE VARIANDO IL N° DI GIRI. • CARATTERISTICHE – MODELLO: EBM MRG118 – ALIMENTAZIONE ELETTRCA: 230V ca – POTENZA 60 W – COLLEGATO CON 2 CABLAGGI UNO DI POTENZA E UNO DI SEGNALE ALIMENTAZIONE 230 V SEGNALE CONTROLLO NUMERO DI GIRI INOVIA SOLAR TANK: CIRCUITO GAS BRUCIATORE • COMPITO – PROGETTATO PER OTTIMIZZARE LA COMBUSTIONE A PREMISCELAZIONE CHE VIENE EFFETTUATA DAL SISTEMA VENTILATORE-VALVOLA GAS • CARATTERISTICHE – BRUCIATORE ECOLOGICO IN ACCIAIO INOX AISI – RIDOTTE EMISSIONI INQUINANTI DI Nox (CALDAIA CLASSE 5 NOX) – FACILMENTE ESTRAIBILE DAL FRONTALE – DUE ELETTRODI MONTATI: UNO DI SCARICA E UNO DI IONIZZAZIONE – PREGETTATO PER G20 G30 G31 Service INOVIA SOLAR TANK: CIRCUITO GAS SICUREZZE TERMICHE • • Service COMPITO – EVITA SOVRATEMPERATURE IN CALDAIA O SU LATO FUMI CARATTERISTICHE – TERMOSATATO MASSIMA TEMPERATURA – TEMPERATURA DI INTERVENTO 103 °C, RIARMO AUTOMATICO – IN CASO DI INTERVENTO IL DISPLAY VISUALIZZA E02 – SONDA FUMI F1 : – PRESERVA I CONDOTTI DI ESPULSIONE – CON LA TEMPERATURA FUMI TRA I 110° C E I 120°C VIENE FORZATA LA MODULAZIONE – OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA LED TERMOFUSIBILE F2 SEGNALANO LIMITAZIONE TEMPERATURA SONDA SCARICO FUMI (E10) – TERMOFUSIBILE F2: – L’INTERVENTO DI F2 INDICA UNO SCARSO SCAMBIO TERMICO – SE LA TEMPERATURA FUMI, PRIMA DI PASSARE PER LO SCAMBIATORE CONDENSANTE, SUPERA I 140° BLOCCA IMMEDIATAMENTE IL BRUCIATORE INTERROMPENDO LA SONDA FUMI (E09) SONDA FUMI F1 INOVIA SOLAR TANK: CIRCUITO GAS SIFONE SCARICO CONDENSA • • Service COMPITO – CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO DEL GRUPPO CONDENSANTE – EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO CONDENSA CARATTERISTICHE – DIAMETRO RACCORDO COLLEGAMENTO: 25 mm. – TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE PLASTICO L= 45 cm – PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL CASO IL SIFONE SI ASCIUGHI INOVIA SOLAR TANK: CIRCUITO GAS INOVIA COND : TARATURA VALVOLA GAS Service COME PER TUTTE LE CALDAIE A CONDENSAZIONE PREMISCELATE LE TARATURE DEL GAS SI ESEGUONO SOLO CON L’UTILIZZO DELL’ANALIZZATORE DI COMBUSTIONE E SEGUENDO LA PROCEDURA SOTTO INDICATA. ATTIVAZIONE SPAZZACAMINO • ENTRARE IN MODALITA’ SPAZZACAMINO SEGUENDO LE IDICAZIONI SOTTO RIPORTATE: – CHIUDERE IL CONTATTO TA – TENERE PREMUTO I PULSANTI A+B+D IN FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’ P01 CON IL RELATIVO VALORE IMPOSTATO – PREMERE CONTEMPORANEAMENTE I TASTI A e B ; IL DISPLAY INDICHERA’ LP + SIMBOLO SPAZZACAMINO (FUNZIONE SPAZZACAMINO ATTIVA) A+B INOVIA SOLAR TANK: CIRCUITO GAS INOVIA COND : TARATURA VALVOLA GAS Service REGOLAZIONE MINIMO GAS 1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI PAGINA PRECEDENTE) 2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL DISPLAY DA’ LA INDICAZIONE LP RIPORTATA IN FIGURA, OVVERO ATTIVAZIONE DELLA FUNZIONE SPAZZACAMINO MINIMA POTENZA, ALTERNATA AL VALORE DELLA TEMPERATUTRA DI MANDATA) 3. AVVIARE ANALIZZATORE DI COMBUSTIONE 4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (8,7% - 9,3%) 5. AGIRE SULLA VITE INICATA IN FIGURA PER MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA (AVVITANDO CO2 AUMENTA) REG. MINIMO GAS NB LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO DI ¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2 LETTO SULLO STRUMENTO RIMANGA COSTANTE INOVIA SOLAR TANK: CIRCUITO GAS INOVIA COND : TARATURA VALVOLA GAS Service REGOLAZIONE MASSIMO GAS 1. PREMERE DIVERSE VOLTE I TASTI A O B FINO A CHE IL DISPLAY NON INDICA DP ALTERNATO AL VALORE DELLA TEMPERATURA DI MANDATA (FUNZIONE FORZATURA MASSIMA POTENZA ATTIVATA) 2. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (ES. METANO 9,3% – 9,9%) 3. AGIRE SULLA VITE INDICATA IN FIGURA PER MODIFCARE IL VALORE DI CO2 ALLA MASSIMA POTENZA (AVVITANDO CO2 DIMINUISCE) REGOLAZIONE MASSIMO GAS INOVIA SOLAR TANK: CIRCUITO GAS RINNOVA COND X : TARATURA VALVOLA GAS Service COME PER TUTTE LE CALDAIE A CONDENSAZIONE PREMISCELATE LE TARATURE DEL GAS SI ESEGUONO SOLO CON L’UTILIZZO DELL’ANALIZZATORE DI COMBUSTIONE E SEGUENDO LA PROCEDURA SOTTO INDICATA. ATTIVAZIONE SPAZZACAMINO 1. ENTRARE IN MODALITA’ SPAZZACAMINO SEGUENDO LE IDICAZIONI SOTTO RIPORTATE: CHIUDERE IL CONTATTO TA TENERE PREMUTO I PULSANTI A+B+D IN FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’ Pr ALTERNATA AL CODICE 01 PREMERE CONTEMPORANEAMENTE I TASTI A e B ; IL DISPLAY INDICHERA’ LP (FUNZIONE SPAZZACAMINO ATTIVA) INOVIA SOLAR TANK: CIRCUITO GAS A+B RINNOVA COND X : TARATURA VALVOLA GAS Service REGOLAZIONE MINIMO GAS 1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI PAGINA PRECEDENTE) 2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL DISPLAY DA’ LA INDICAZIONE LP RIPORTATA IN FIGURA, OVVERO ATTIVAZIONE DELLA FUNZIONE SPAZZACAMINO MINIMA POTENZA, ALTERNATA AL VALORE DELLA TEMPERATUTRA DI MANDATA) 3. AVVIARE ANALIZZATORE DI COMBUSTIONE 4. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (ES. METANO: 8,7% - 9,3%) 5. AGIRE SULLA VITE INICATA IN FIGURA PER MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA (AVVITANDO CO2 AUMENTA) REG. MINIMO GAS NB LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO DI ¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2 LETTO SULLO STRUMENTO RIMANGA COSTANTE INOVIA SOLAR TANK: CIRCUITO GAS RINNOVA COND : PROCEDURA TARATURA GAS Service REGOLAZIONE MASSIMO GAS 1. PREMERE DIVERSE VOLTE I TASTI A O B FINO A CHE IL DISPLAY NON INDICA DP ALTERNATO AL VALORE DELLA TEMPERATURA DI MANDATA (FUNZIONE FORZATURA MASSIMA POTENZA ATTIVATA) 2. CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (ES. METANO 9,3% – 9,9%) 3. AGIRE SULLA VITE INDICATA IN FIGURA PER MODIFCARE IL VALORE DI CO2 ALLA MASSIMA POTENZA (AVVITANDO CO2 DIMINUISCE) REGOLAZIONE MASSIMO GAS INOVIA SOLAR TANK: CIRCUITO GAS