Fig.1 Connection Fig.2 Dimensions Fig.3 Distances Fig.4 Hook up (1) AC/DC input (2) DC output (load) (3) Diagnostic Output (dry contact, NC output OK) (4) Green LED : output OK (5) Red LED: overload (6) Output voltage adjustment 0.5-0.6 Nm 4.42-5.30 lbf in Fig.7 – Input connection Models File No.: NPSM480-24 – Single phase / DC input power supply I.S.NPSM480-24.V2.0 Rev.: 2.0 Nextys SA. Via Luserte Sud 6, 6572 Quartino – Switzerland Phone: +41-(0)91 8401446 / 8401448; Fax: +41-(0)91 8401447 Note: for the latest version of this “Instruction Manual” please visit www.nextys.com READ THIS CAREFULLY BEFORE INSTALLATION! Dimension W D H Fig.5 – Recommended connecting cable Instruction Manual mm (inc) 73 (2.83) 125 (4.92) 140 (5.52) Distance A B mm (inc) 20 (0.8) 50 (2.0) Unhook Fig.6 – Input protection Fuse AT 6.3 A or MCB 6A C curve or 4A D curve (see point 4 next page). Solid: 2.5mm² / 12AWG For USA and Canada, use the fuse type closest to the European equivalent type Stranded:1.5mm² / 12AWG L: 6.0-7.5mm / 0.24-0.30 in Surge protection: it is strongly recommended to provide external surge arresters according to local regulations. Before operating, read this manual thoroughly and retain it for future reference. Non-respect of these instructions may reduce performances and safety of the devices and cause danger for people and property. The products must be installed, operated, serviced and maintained by qualified personnel in compliance with applicable standards and regulations. Don’t open the device, it does not contain replaceable components, the tripping of the internal fuse (if included) is caused by an internal failure. Don’t repair or modify the device, if malfunction or failure should occur during operation, send unit to the factory for inspection. No responsibility is assumed by Nextys SA for any consequences deriving from the use of this material. CAUTION RISK OF BURNS, EXPLOSION, FIRE, ELECTRICAL SHOCK, PERSONAL INJURY. Never carry out work on live parts! Danger of fatal injury! The product’s enclosure may be hot, allow time for cooling product before touching it. Do not allow liquids or foreign objects to enter into the products. To avoid sparks, do not connect or disconnect the device before having previously turned-off input power and wait for capacitors discharge. LEGGERE ATTENTAMENTE PRIMA DELL’INSTALLAZIONE! Prima dell’installazione, leggere attentamente queste istruzioni e conservarle per future consultazioni. L’inosservanza delle presenti istruzioni può compromettere le caratteristiche e la sicurezza dell’apparecchio e causare pericolo per le persone e le cose. Il prodotto deve essere installato, utilizzato e riparato da personale qualificato e nel rispetto delle normative vigenti. Non aprire il prodotto, esso non contiene componenti sostituibili, il guasto del fusibile interno (se previsto) è causato da un guasto interno. Non tentare di riparare o modificare il prodotto, se durante il funzionamento si verificano guasti o anomalie, inviarlo al produttore per il controllo. Nextys SA non si assume nessuna responsabilità per qualunque conseguenza derivante dall’uso di questo materiale. A LIRE ATTENTIVEMENT AVANT L’INSTALLATION! Lisez ces instructions avant l'installation, conservez ce manuel pour référence future. Défaut de se conformer à ces instructions peut affecter les caractéristiques et la sécurité du dispositif de danger et de causer aux personnes ou aux biens. Le produit doit être installés, exploité et entretenus par personnel qualifié et en conformité avec les règlements. N'ouvrez pas le produit, il ne contient aucune pièce réparable, le déclenchement du fusible interne (le cas échéant) est causée par un défaut interne. Ne pas tâtonné pour réparer ou modifier le produit, si des défaillances se produisent pendant le fonctionnement ou les dysfonctionnements, le retourner au fabricant pour inspection. Nextys SA n'assume aucune responsabilité des conséquences éventuelles découlant de l'utilisation de cette documentation. ATTENZIONE RISCHIO USTIONI, ESPLOSIONE, INCENDIO, SCOSSA, LESIONI GRAVI. Non effettuare mai operazioni sulle parti in tensione! Pericolo di lesioni letali! Il contenitore può scottare, lasciar quindi raffreddare il dispositivo prima di toccarlo. Non far entrare liquidi o oggetti estranei nel dispositivo. Per evitare scintille, non collegare o scollegare l'apparecchiatura prima di avere tolto tensione di ingresso e prima che sia avvenuta la scarica dei condensatori. AVVERTISSEMENT RISQUE DE BRULURES, EXPLOSION, INCENDIE, ELECTROCUTION, DOMMAGE AUX PERSONNES. Ne jamais effectuer des opérations sur les parties sous tension! Danger de mort! Le récipient peut graver, le laisser refroidir avant de toucher l'appareil. Ne vous laissez pas liquide ou corps étranger dans l'appareil. Pour éviter des étincelles, ne pas connecter ou déconnecter l'équipement jusqu'à ce que vous avez supprimé la tension d'entrée et avant qu'elle n'ait lieu de décharge des condensateurs. INTENDED USE USO PREVISTO UTILISATION These are Class I isolation devices suitable for SELV and Sono dispositivi in classe di isolamento I e adatti per Les produits sont de classe I isolement, propice pour les PELV circuitry and are designed to be mounted on DIN rail and applicazioni SELV e PELV, sono dotati di aggancio per il circuits TBTS et TBTP et sont équipé d'un crochet pour installed inside a protective enclosure. They are intended for montaggio su guida all’interno di quadri elettrici o contenitori di montage sur rail dans les armoires ou conteneurs sécurisés, general use such as in industrial control, communication, and protezione per l’utilizzo con controllori industriali, unità di pour utilisation avec les contrôleurs industriels, des modules de instrumentation equipment. comunicazione o apparecchi di misura. communication ou les unités de mesure. Don’t use these devices in applications where malfunction may Non utilizzare in applicazioni in cui un eventuale guasto può Ne pas utiliser ces dispositifs dans l'application où un cause injury or death. comportare rischio di lesioni o di morte. dysfonctionnement pourrait entraîner des blessures ou morts. ENVIRONMENTAL CHARACTERISTICS CARATTERISTICHE AMBIENTALI CARACTÉRISTIQUES D'ENVIRONNEMENT Installation in a Pollution Degree 2 environment, Overvoltage Usare in ambienti con Grado di Inquinamento 2 e Categoria di Utilisé dans les environnements avec degré de pollution 2, Category II, according to IEC 664-1 Sovratensione II, secondo IEC 664-1. catégorie de surtension II selon IEC 664-1. Do not use in wet area or subject to moisture. Non far funzionare l'apparecchio in un ambiente umido o Ne pas faire fonctionner l'appareil dans un environnement Carefully recycle the product and related batteries according to soggetto a formazione di condensa. humide ou soumis à la condensation. local regulations. Riciclare il prodotto e le batterie collegate, nel rispetto delle Recycler les produits et les accus, conformément à la normative locali vigenti. réglementation locale. INSTRUCTIONS 1) Description: DIN rail mountable primary switched-mode power supply with 187...265Vac - 250…345Vdc input, suitable for Single phase main line and DC line. 2) Installation: use DIN-rails according to EN 60715. Installation should be made vertically (see Fig.4). For better device stability fix the rail to the wall close to the point where the device is to be mounted. In order to guarantee sufficient convection, we recommend observing a minimum distance to other modules (see Fig.3). The device is provided with a thermal protection, a limited air flow can causes the thermal protection tripping. The SMPS automatically restarts after cooling. To get normal operation reduce the temperature of the air surrounding the power supply, increase the ventilation or reduce the load. 3) Connections: the device is equipped with pluggable screw terminals. To avoid sparks, do not connect or disconnect the connectors before having previously turned-off input power and waited capacitors discharge. In order to comply with UL certification, use appropriate copper cables of indicated cross section, designed for an operating temperatures of 60°C (for ambient <45°C) and 75°C (for ambient < 60°C). Strip the connecting ends of the wires according to the indication on Fig.5 and ensure that all strands of a stranded wire enter the terminal connection. 4) Input protection : the device input is provided with varistors against overvoltage. Input isn’t provided with internal fuses, thus an external short circuit/overcurrent protection must be provided by the end user (see Fig.6). For operation on a single-phase system, a protection fuse on the phase must be provided. Surge protection: it is strongly recommended to provide external surge arresters according to local regulations. 5) AC input connection: the device can be connected to single-phase AC lines with Un 230 Vac (see Fig.7). 6) DC input connection: connect L terminal to + pole, N terminal to – pole and I terminal to GND. Rated voltage 250...345Vdc. The device is also suitable for photovoltaic or wind turbine applications. 7) Output connection: The device is suitable for SELV and PELV circuitry. Uout can be adjusted with a potentiometer (see Fig.1) Check Uout before connecting the power supply to the load. With output voltage set to the max. value, the continuous current must not exceed the nominal power. 8) Parallel connection and redundancy: more power supplies can be connected in parallel to increase power. Uout must be set uniformly (±100mV) on each power supply and the wiring must be symmetrical to ensure an equal current distribution. For redundant connection, an external isolating device must be used. 1 9) Output protection: the device is protected against overload (OL) / short circuit (SC) / overvoltage (OV) / overtemperature (OT). OL and SC: are controlled by an hiccup auto-reset protection with the following behaviour: OL behaviour: Max. OL = In x 1.5 with constant output voltage for max. 5s. If the current is ≥ In x 1.5 the unit enters the OL protection and starts an ON/OFF cycle (hiccup). SC behaviour: the device supplies the indicated short circuit peak current for 250 ms if the output current exceeds In x 1.5 the device enters into a controlled ON/OFF cycles (hiccup mode). The output voltage drops to a voltage value depending on the impedance of the failed load circuit. Output OV circuit protection: the output is protected against potential OV due to internal malfunction or coming from the load for Uout Unom x 1.2 – 1.3. OT protection: turns off the device if the internal temperature exceeds a safe limit. The device restarts automatically after cooling down. To recover to normal operation reduce air temperature surrounding the power supply, increase cooling or reduce load. When operating at normal load and > 45°C reduce the output power with 10W/°C. 10) Feeding DC motors: it is possible to feed DC motors considering that when a motor starts-up under effort its consumption is much higher than the nominal current and it can trigger overcurrent protection. NOTE: motors can generate high conducted noise on the DC line. Therefore it is not recommended to feed on the same line motors and equipment sensitive to noise. 11) Warranty: power supplies are guaranteed free from factory defects for the time specified in the “Sales Conditions” Failures caused by misuse, external and/or abnormal events (i.e. overvoltage, over temperatures) or non-respect of above parameters and standards, are not covered by warranty. Opening the housing of the product makes warranty to be no longer valid. In order to improve the products Nextys SA reserves the right to change product specifications, ratings and data without previous advice. DECLARATION OF CONFORMITY NEXTYS SA. (www.nextys.com) Via Luserte Sud 6, 6572 Quartino - Switzerland Phone: +41-(0)91 840 14 46 / 840 14 48; Fax: +41-(0)91 840 14 47 E-mail: [email protected] TECHNICAL DATA (1) Model type INPUT DATA Input rated voltage Frequency Input rated current Inrush peak current Power factor Internal protection fuse OUTPUT DATA Rated voltage Voltage adjustment Continuous current (Uout nom.) Overload limit Short circuit peak current Load regulation Ripple Hold up time Output protections We declare under our sole responsibility that the material under described: Output overvoltage protection Status signals Has passed all processing inspections and the final test and it is in conformity with the product requirements, including all reference codes and supply specifications. ROHS compliance: the product respects the EC requirements related to ROHS substances, according to “Restriction of Hazardous Substances” as per document 2011/65/UE REACH compliance: the product respects the EC requirements related to REACH SVHC directive (2010) Note: all the reported information comes from our suppliers, NEXTYS SA. Has not run any test to evaluate if the specific elements are present. IND.CONT.EQ. 4WX9 Date: 13.10.2015 AC: single phase, 200…240Vac (range 187…265Vac) DC: 250...725Vdc (UL certified from 300Vdc to 500Vdc) 47...63 Hz / DC 2.5A < 20A > 0.95 None, external fuse must be provided Fuse AT 6.3 A or MCB 6A C curve or 4A D curve – (See Fig.6) It is strongly recommended to provide external surge arresters (SPD) according to local regulations. (4) (3) (5) (Low Voltage Directive) (EMC directive) (Conducted emissions) (Safety Standards) (IND. CONT. EQ. 4WX9 file no. E356563) (Generic immunity standard for industrial environments) (Generic emission standard for industrial environments) The product manager Place: Quartino, Switzerland Marius Ciorica “Overload” LED (red) “DC OK” relay: Alarm contact threshold Parallel connection Redundant parallel connection GENERAL DATA Efficiency Dissipated power Operating temperature Certifications and approvals Reference standards: (3) NPSM480-24 “DC OK” LED (green) Description Single phase switching power supply IN 200 - 240 Vac (250 - 345Vdc) / OUT 24 Vdc 20 A 2006/95/EC (2006) 2004/108/EC (2004) EN55011:2009 /A1:2010 EN60950-1:2006 /A12:2011 UL508 EN61000-6-2:2005 EN61000-6-4:2007 /A1:2011 (2) External protection on AC line This Declaration of Conformity is suitable to the European Standard EN 45014 "General criteria for supplier’s declaration of conformity". Code NPSM480-24 NOTES Derating Humidity Life time expectation Overvoltage category Pollution degree Input / output isolation Input / ground isolation Output / ground isolation Standards, Approvals / Certifications EMC Standards Protection degree Connection terminals Case Material Mounting Rail Approx. weight Size (W x H x D) Rail mounting information (1) (2) (3) (4) (5) 24Vdc 23…28Vdc 20A > 28A per 5s 50A < 1% ≤ 100 mVpp > 20ms Hiccup at the overload limit with auto reset Over temperature Overvoltage (See point 9) > 33Vdc on = all functions and IN/OUT parameter are OK off = Uout < 0.9 x Unom on = Iout >110% and <150% off = Iout ≤ In +10% Contact closes when the power supply is turned-on and remains closed with Uout ≥ minimum threshold voltage. The behavior of the contact operation, follows the LED "DC OK" Uout < 21.6Vdc Up to 4 units for increased power (see point 8) (see point 8) > 92% < 42W - 40°C…+70°C / overtemperature protection (Start-up type tested: - 40°C) - 10W/°C over 45°C 5…95% r.H. non condensing 65496h (7.4 years) at 25°C ambient full load II 2 (IEC 664-1 ) 4.2 kVdc 2.2 kVdc 0.75 kVdc UL508 (Certified) – EN60950 (reference) – CE Marking EN61000-6-4, EN61000-6-2 IP20 according to EN60529 2.5 mm², screw type pluggable (24...12 AWG) Aluminum IEC 60715/H15/TH35-7.5(-15) 1.0 kg (2.2 lbs) 73.0 x 140.0 x 125.0mm (See Fig.2) Vertical – Horizontal, allow spacing between adjacent items (See Fig.3) NOTES if not diversely specified, all technical data are typical and measured at 25°C, Uin 230Vac, and nominal U, I output. see points 5) and 6) on “instructions” page. at full load, at 25°C. at full load, at 25°C, measured with probe connected to 100nF/20MHz termination. protected, with a crow bar diode, against voltage peaks and overvoltage coming from the DC line caused by inductive loads, see point 9) on “instructions” page. 2