ELETTROMECCANICA COLOMBO
Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901
COMPANY PROFILE
Foundation
1901
Location
20010 MESERO (MI)
25 km west of Milano
Company Form
Limited Partnership Company
Total asset 2.098.000 €
Activity
Production of electric transformers
oil immersed, cast resin, dry type
power: up to 20.000 KVA
Surface
Offices
mq 200
Workshop mq 2150
Total area mq 4500
Production
1999
2000
2001
629.215 KVA
666.910 KVA
758.480 KVA
Management
Managing Director
Quality Assurance
Secretariat
Sales
Design & Engineering
Production
Testing
Purchasing
Administration
Mainini Gianni
Pecol Mario
Gambirasio Romilda
Mainini Matteo
Pastore Franco
Cannistra Antonio
Garegnani Luigi
Mainini Simone
Liguori Mauro
Personnel
total 25 employees
part of the production is made by co-operating subcontractors
Contact Numbers
phone
fax
e mail
internet
0039 02 9787070 - 9787313
0039 02 9789198
[email protected]
www.elettrocolombo.com
ELETTROMECCANICA COLOMBO
Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901
MAIN EQUIPMENT
Nr
Nr
Nr
Nr
3
2
2
2
wire winding machines for high voltage coils
bar winding machines for high and low voltage coils
foil winding machines for high voltage coils
plate windings machines for low voltage coils
Nr
1
complete plant for cast resin transformers with
set of dies(shell moulds)
quartz silos
resin mixers
autoclave
furnaces
Nr
1
complete plant for oil transformers with
centrifugal oil clarifier
degasifier
vacuum tank
autoclave
furnaces
Nr
1
1
complete line for the assembly of distribution transformers
complete line for the assembly of power transformers
Nr
1
complete test room with
motor-alternator group 200 kVA 400V 50hz
frequency converters 50-60hz,50-100hz,50-200hz
induction voltage regulator 250 kVA
voltage elevator transformer 100 kVA 160-320 kV
capacitor batteries 600 V 400kVAr
impulse generator 1200KV 10kj
oscillograph double path with image recording
sphere spark gap 400 mm diameter
partial discharges measuring system
monitoring and control panel
measuring and registering instruments
Nr
4
cranes : 1x40 ton , 2x10 ton, 1x5 ton
Nr
2
fork lifts ton 3,5 and ton 1,2
Nr
2
trucks ton 6 and ton 1
ELETTROMECCANICA COLOMBO
Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901
PRODUCTION PROGRAM
Low voltage transformers LV/LV
Dry type
rating up to 630 KVA nominal voltage up to 1,1KV
Oil immersed rating up to 630 KVA nominal voltage up to 1,1KV
Distribution transformers MV/LV
Dry type
rating up to 2500 KVA and nominal voltage up to 24KV
Dry type cast resin rating up to 2500 KVA and nominal voltage up to 36KV
Oil immersed
rating up to 2500 KVA and nominal voltage up to 72KV
Power transformers HV/LV HV/MV
Dry type cast resin rating up to 10 MVA and nominal voltage up to 36Kv
Oil immersed
rating up to 25 MVA and nominal voltage up to 72 Kv
Power transformers can be equipped with on load tap changer.
The production range includes, besides the standard types, autotransformers and
transformers to be used for starting , insulation , earthing , induction furnace, rectifiers .
MANUFACTURING STANDARD
The transformers produced by Elettromeccanica Colombo are manufactured in
compliance with the following standards and relevant updating documents:
oil immersed transformers
CEI 14-4
IEC 76
IEEE ANSI C 57,12.00
dry type and cast resin transformers
CEI 14-8
IEC 726
IEEE ANSI C 57,12.01
Upon request it is possible to produce transformers in compliance with any other
Standard, like BSS, VDE, AFNOR ...
QUALITY ASSURANCE SYSTEM
All transformers are submitted to accurate controls during the production and to
final test in our test room , where we carry out the routine test and type tests.
Special test -on request-are made normally at CESI Institute in Milano or in
others University Electrical Departments.
Our firm has made several complete tests at CESI Institute with positive results ;
that proves the reliability of our transformers.
Particular care is given to quality problems starting from the design-planning
moment .The components used are accurately checked in the purchasing ,
stocking , construction and assembling phases .
The company is applying a Quality Assurance System according to ISO 9001
Standard, certified from NQA LTD - England - NR 14794
ELETTROMECCANICA COLOMBO
Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901
T=type
DISTRIBUTION TRANSFORMERS SYNTETIC REFERENCES
H=dry type transformer R=cast resin L=liquid immersed IR AC Internal Ref
CUSTOMER
COUNTRY
Tecnimont
Italy-China
Enel (Nat.Electr.Board)
Italy
ACEA (Rome Electr.Co.) Italy
Myren
Sweeden
Schneider Italia
Italy
Erect Co
Iran
Milano Linate Airport
Italy
Iskraft
Iceland
Siemens
Austria
Ardry Tr
Philippines
Benetton Group
Italy
ABB sae sadelmi
Italy
Ansaldo Genova
Italy
Eximet
Czech Rep
Ministry of Electricity
Yemen
Italtel
Italy
Europelec
France
Locarno Tunnel
Switzerland
Bridgwater Paper
England
H.Orbis
Germany
Vilma
Greece
Cem
Tunisie
DNL
Italy
21 Inv/Ben.Gr
Italy
Helmke
France
Beron
Uruguay
Granitos & Marmoles
Colombia
Pompe Travaini
Italy
Ilva Laminati
Italy
Manessman Rexroth
Germany
Myfair
Taiwan
Somafe
Algerie
Euroallumina
Italy
Everwell -US Multicorp.
Hong Kong
Inductotherm
England
M.S.KTN
Syria
Hydro Water Power Eng. Hong Kong
Eagle
Egypt
Aster
Italy
S.B.E.
Bangladesh
ABB Sace
Italy
Sumitomo
Japan
Electrodinamica
Argentina
Orion
Israel
Amex
India
NIOC
Nigeria
Ferrovie Stato(Nat.Railway)Italy
Rondine
Italy
Koncar
Singapore
Roquette
Italy
T&R
England
T
Q KVA
KV NOTES
IR
L
4 2000
6-0,4
600
L
8
30 380v-380v insulation transformers 500
L
5 630
8,4-0,4 sealed type
600
R
2 1000 11/6/3-0,4 for test room
910
R
1 250
8,4/20
000
L 150 100
magnetic cores
007
H 15 800
15-0,4
500
R
3 400
15-0,4 earhtquake calculated
900
L
2 2500 6/2x0,685 for rectifier
107
L
4 2500
34,5-0,46 silicon oil/onan-onaf
911
H
9 630
20-0,4
600
801
R
2 400
0,5-0,4 primary/secondary casted
R
1
20
21-0,5 single phase HV-LV resin 801
R
2 250
6-0,4
103
L 121 750
0,4-11 step up transf
712
A
4
6
400-240 three-mono phase
701
L
4 1600
13,8-0,4 sealed type
706
L
3 1600
16-0,3 silicon oil
300
R
1 2500
11-0,4 fan ventilation AN-AF
500
L
8 1600
11-0,4
200
R
3 2500
20-0,4 HV -LV copper windings 800
L 10 1600
30-0,4
400
L
6 2500
20-0,4 heavy duty for rolling mill 106
H
1
25
20 hearting transformer
500
L
3 2000
15-0,4
500
L
3 630
6,0-0,2
600
L
2 2000
34-11
700
H
1 300
0-750 rotary transformer
802
H
1 900
11-0,4 dry type for crane
600
R
2 1250
10-0,4 higly reduced losses
708
R
4 1250 11,4-22,8/04 with cubicles and fans
800
L 20 100
30-0,4
004
L
4 1600
15-0,4 nytrogen filling
710
R
2 500
11/22-0,4
803
R
1 2600
10-0,4 k 13 load factor
000
L
4 1000
15-0,4 sealed type
600
H
2 560
380-415 autotransf. for motor start 700
L
2 1000
11-0,4
900
R
4 1000
20-0,4 HV-LV encapsulated
710
R
2 1600
11-0,4
012
L
1 1250
15-0,4
600
H
2
60
400-230
910
R
4 500
13,2/400 plug in HV terminals
102
R
4 1250
22-0,4
804
R 10 315
11-0,4 resin coils
804
L 18 200
400-230 autotransf.oil cooled
300
H 17 250 380v-380v insulation transformers 600
H
2 1600
15-0,4
600
H
4 1500
400-400 low inrush current
103
L 22 2000
14-0,4
700
R
1
35
33-0,2 1phase for windgenerator 012
A C
I
M 967
I
E 033
I
I
F 852
I
F
M 971
F 091
ELETTROMECCANICA COLOMBO
Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901
T=type
POWER TRANSFORMERS SYNTETIC REFERENCES
H=dry type transformer R=cast resin L=liquid immersed IR AC:Internal Ref
CUSTOMER
Ems
Pechiney All.
TTR
Electronic
Dani
Eurobox
De Stefani
Dani
Ardry trading
Siemens
British Steel
Min.Agric.Tun. SidiBarrak/Siba
Snam Progetti
CEM
Viparita
Coca Cola
Nuova Walter
Ansaldo Energia
Sviluppo Sud
Nuovo Pignone
Ingersoll Dresser
Ingersoll Dresser
ABS
Emit
SNR
Arsenale Militare
Ministerio Transporte
Zuccherificio Molise
Helmke Italia
Zarelli Ind Chimiche
Saldomeccanica
S.Naz.O.S
T&R Group
API
El.pi/CocaCola
Ferrari
T&R Group
Air Liquide
ABA
Kem
Fruedel
Ispa due
Elettr. RINI
ABA
Lombarda Trasformatori
Coca Cola
Simir
Eurogen
Inductotherm
Feralpi
DNL
Flowserve
Stc-Atel
COUNTRY
Italy
France
Italy
Italy
Italy
Italy
Italy
Italy
Philippines
Austria
England
Tunisie
Italy
Tunisie
Argentina
Uruguay
Italy
Italy
Italy
Italy
Italy
Italy
Italy
Malaysia
France
Italia
Uruguay
Italy
Italy
Italy
Italy
Italy
England
Italia
Albania
Italy
England
France
Germany
Greece
Thailand
Italy
Italy
Germany
Italy
Philippines
Italy
Italy
England
Italy
Italy
Italy
Italy
T
L
L
L
R
L
R
R
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
R
L
L
L
L
R
R
R
L
L
L
R
R
R
L
R
L
L
R
L
R
L
L
L
L
L
L
L
Q
4
1
1
1
2
2
1
1
2
1
1
2
1
1
3
2
1
2
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
1
4
1
1
16
1
1
1
1
1
1
1
1
2
11
1
1
KVA
4000
10000
6000
3000
3500
3600
4000
4000
5000
5500
7000
10000
10000
4500
5000
5000
4000
5000
19000
10000
12500
10000
4000
6500
8000
4500
5000
15000
7000
5200
4400
3300
3150
6500
8000
4000
3360
3150
3500
3500
3150
3150
7500
3150
12000
7500
10000
5600
4600
3400
3150
10000
20000
KV
10/5
42/5,5
10/6
15/0,4
12,4/2x0750
3/20,8
15/0,4
13,8/4,2
6,9/13,2
6/2x0,865
11/2x0,710
33/5,7
15/6,3
30/0,4
33/2,3
6/0,23
34,5/15
23-13,8
150-20
10,5/34,6
15,0/6
6,0/0,4
21-6,3
20-0,6
69/13,8
20/0,4
6,3/0,4
6/15
15/0,4
20/0,4
5,5/20
20/5,5
11/0,4
20/6,9
34,5/6
15/0,4
20/2x680
6/0,4
30/0,4
21/6,3
6,6/0,4
20/0,4
15/6
30/0,69
15/6
34,5/4,16
15/6
23,9/4,16
22/1,15
15/0,66
22/0,42
NOTES
IR A C
910
803
904
906
for rectifiers
909
912
905
906
911
912
induction furnace
906
Powered to 12,5with fan 910
905
powered with ventilation 906
for petrol ind.
706
707
801
rewinding
803
on load tap changer
711
711
500
autotransf for motor st. 500
804
600
907
reduced losses
905
902
906
rewinding
601
500
806
806
HV-LV copper windings 901
903
diaphram conservator
on load tap changer
912
907
004
709
single phase
005
autotransf.
803
fan ventilation +40%
703
909
012
011
on load tap changer
012
012
012
103
103
102
104
204
15/0,77-13.31 on load tap changer
16,33/11
205
ELETTROMECCANICA COLOMBO
Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901
REFERENZE SINTETICHE WORLD KNOWN COMPANIES SYNTETIC REFERENCES
Legenda T=type H=dry type transformer R=cast resin L=liquid immersed IR AC:Internal Ref
CUSTOMER
SIEMENS
J.SCHNEIDER
ABB
KONCAR
SUMITOMO
KINDEN
MARUBENI
NIROU TRANSF
HELMKE GROUP
ARDRY TR
FRUEDEL
TRANSF & RECT.
AIR LIQUIDE
COCA COLA
COUNTRY T
A Wien
L
L
L
L
R
I Milano
R
I Milano
R
I Rome
R
I Rome
R
F FramatomeL
D Dortmund R
R
India Baroda R
I Sae Sadelmi
I Sace
L
I Sace
H
I Mi
H
Cz Rep.
R
Singapore H
R
H
R
H
JAPAN
H
JAPAN
R
JAPAN/yemeL
IRAN
L
B
L
D
L
I
R
F
L
USA/PHILIP L
L
L
L
THAILAND R
ENGLAND R
France
R
Italy/Sv.Sud L
R
R
Italy
H
Gr/Albania L
Urugay
L
Philippines R
Italy
H
Q
2
2
1
2
4
1
2
1
1
1
1
1
2
1
1
2
1
27
2
1
1
10
1
4
2
4
3
2
4
10
121
200
1
1
14
1
4
4
4
2
16
48
1
1
1
4
3
1
2
1
2
KVA
4500
2500
5500
2000
1500
630
800
400
250
2000
2500
2000
1600
1600
1600
1000
1600
2000
400
1250
1600
800
1000
600
1000
1200
750
1500
160
2500
KV
6/2X,0865
6/2X,0865
6/2X,0865
16-20/690
10-0,4
NOTES
A C
Corus Maenstaedt Steel Mill
Karprum Cable car
Autotr.for motor start
8,4-20/0,4
8,4-20/0,4
10/5,5
20/0,69
20/0,4
6/0,4
15/6,3
10/0,4
10/0,4
15-20/6
33/415
0,4/0,5
15/0,4
15/0,4
15/0,4
6/0,4
0,4/0,4
22/0,4
0,4/0,4
22/0,4
0,4/0,4
0,4/0,4
22/0,21
11/0,415
Prim & sec casted DMRC Pr.
Primary &sec .casted
Insulation transf.
Insulation transf
Diff power from 50 to 750 kva
50 and 100 kva
10000 22/6,3
400 60/0,4
2000
3150
5000
2500
5000
3150
14,5/0,4
34,5/0460
6,9/13,2
23,9/4,160
6,6/0,4
3000
19000
1600
3150
200
8000
5000
7500
400
10/0,480
150/20
6/0,4
6/0,4
0,4/0,4
34,5/6
6/0,23
34,5/4,16
15/0,4
diff pow up to 5000 kva
hermetic type
Copper windings
Diff power from 400 to 6500 Kva
On load tap ch.
On load tap ch.
Scarica

ELETTROMECCANICA COLOMBO