ELETTROMECCANICA COLOMBO Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901 COMPANY PROFILE Foundation 1901 Location 20010 MESERO (MI) 25 km west of Milano Company Form Limited Partnership Company Total asset 2.098.000 € Activity Production of electric transformers oil immersed, cast resin, dry type power: up to 20.000 KVA Surface Offices mq 200 Workshop mq 2150 Total area mq 4500 Production 1999 2000 2001 629.215 KVA 666.910 KVA 758.480 KVA Management Managing Director Quality Assurance Secretariat Sales Design & Engineering Production Testing Purchasing Administration Mainini Gianni Pecol Mario Gambirasio Romilda Mainini Matteo Pastore Franco Cannistra Antonio Garegnani Luigi Mainini Simone Liguori Mauro Personnel total 25 employees part of the production is made by co-operating subcontractors Contact Numbers phone fax e mail internet 0039 02 9787070 - 9787313 0039 02 9789198 [email protected] www.elettrocolombo.com ELETTROMECCANICA COLOMBO Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901 MAIN EQUIPMENT Nr Nr Nr Nr 3 2 2 2 wire winding machines for high voltage coils bar winding machines for high and low voltage coils foil winding machines for high voltage coils plate windings machines for low voltage coils Nr 1 complete plant for cast resin transformers with set of dies(shell moulds) quartz silos resin mixers autoclave furnaces Nr 1 complete plant for oil transformers with centrifugal oil clarifier degasifier vacuum tank autoclave furnaces Nr 1 1 complete line for the assembly of distribution transformers complete line for the assembly of power transformers Nr 1 complete test room with motor-alternator group 200 kVA 400V 50hz frequency converters 50-60hz,50-100hz,50-200hz induction voltage regulator 250 kVA voltage elevator transformer 100 kVA 160-320 kV capacitor batteries 600 V 400kVAr impulse generator 1200KV 10kj oscillograph double path with image recording sphere spark gap 400 mm diameter partial discharges measuring system monitoring and control panel measuring and registering instruments Nr 4 cranes : 1x40 ton , 2x10 ton, 1x5 ton Nr 2 fork lifts ton 3,5 and ton 1,2 Nr 2 trucks ton 6 and ton 1 ELETTROMECCANICA COLOMBO Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901 PRODUCTION PROGRAM Low voltage transformers LV/LV Dry type rating up to 630 KVA nominal voltage up to 1,1KV Oil immersed rating up to 630 KVA nominal voltage up to 1,1KV Distribution transformers MV/LV Dry type rating up to 2500 KVA and nominal voltage up to 24KV Dry type cast resin rating up to 2500 KVA and nominal voltage up to 36KV Oil immersed rating up to 2500 KVA and nominal voltage up to 72KV Power transformers HV/LV HV/MV Dry type cast resin rating up to 10 MVA and nominal voltage up to 36Kv Oil immersed rating up to 25 MVA and nominal voltage up to 72 Kv Power transformers can be equipped with on load tap changer. The production range includes, besides the standard types, autotransformers and transformers to be used for starting , insulation , earthing , induction furnace, rectifiers . MANUFACTURING STANDARD The transformers produced by Elettromeccanica Colombo are manufactured in compliance with the following standards and relevant updating documents: oil immersed transformers CEI 14-4 IEC 76 IEEE ANSI C 57,12.00 dry type and cast resin transformers CEI 14-8 IEC 726 IEEE ANSI C 57,12.01 Upon request it is possible to produce transformers in compliance with any other Standard, like BSS, VDE, AFNOR ... QUALITY ASSURANCE SYSTEM All transformers are submitted to accurate controls during the production and to final test in our test room , where we carry out the routine test and type tests. Special test -on request-are made normally at CESI Institute in Milano or in others University Electrical Departments. Our firm has made several complete tests at CESI Institute with positive results ; that proves the reliability of our transformers. Particular care is given to quality problems starting from the design-planning moment .The components used are accurately checked in the purchasing , stocking , construction and assembling phases . The company is applying a Quality Assurance System according to ISO 9001 Standard, certified from NQA LTD - England - NR 14794 ELETTROMECCANICA COLOMBO Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901 T=type DISTRIBUTION TRANSFORMERS SYNTETIC REFERENCES H=dry type transformer R=cast resin L=liquid immersed IR AC Internal Ref CUSTOMER COUNTRY Tecnimont Italy-China Enel (Nat.Electr.Board) Italy ACEA (Rome Electr.Co.) Italy Myren Sweeden Schneider Italia Italy Erect Co Iran Milano Linate Airport Italy Iskraft Iceland Siemens Austria Ardry Tr Philippines Benetton Group Italy ABB sae sadelmi Italy Ansaldo Genova Italy Eximet Czech Rep Ministry of Electricity Yemen Italtel Italy Europelec France Locarno Tunnel Switzerland Bridgwater Paper England H.Orbis Germany Vilma Greece Cem Tunisie DNL Italy 21 Inv/Ben.Gr Italy Helmke France Beron Uruguay Granitos & Marmoles Colombia Pompe Travaini Italy Ilva Laminati Italy Manessman Rexroth Germany Myfair Taiwan Somafe Algerie Euroallumina Italy Everwell -US Multicorp. Hong Kong Inductotherm England M.S.KTN Syria Hydro Water Power Eng. Hong Kong Eagle Egypt Aster Italy S.B.E. Bangladesh ABB Sace Italy Sumitomo Japan Electrodinamica Argentina Orion Israel Amex India NIOC Nigeria Ferrovie Stato(Nat.Railway)Italy Rondine Italy Koncar Singapore Roquette Italy T&R England T Q KVA KV NOTES IR L 4 2000 6-0,4 600 L 8 30 380v-380v insulation transformers 500 L 5 630 8,4-0,4 sealed type 600 R 2 1000 11/6/3-0,4 for test room 910 R 1 250 8,4/20 000 L 150 100 magnetic cores 007 H 15 800 15-0,4 500 R 3 400 15-0,4 earhtquake calculated 900 L 2 2500 6/2x0,685 for rectifier 107 L 4 2500 34,5-0,46 silicon oil/onan-onaf 911 H 9 630 20-0,4 600 801 R 2 400 0,5-0,4 primary/secondary casted R 1 20 21-0,5 single phase HV-LV resin 801 R 2 250 6-0,4 103 L 121 750 0,4-11 step up transf 712 A 4 6 400-240 three-mono phase 701 L 4 1600 13,8-0,4 sealed type 706 L 3 1600 16-0,3 silicon oil 300 R 1 2500 11-0,4 fan ventilation AN-AF 500 L 8 1600 11-0,4 200 R 3 2500 20-0,4 HV -LV copper windings 800 L 10 1600 30-0,4 400 L 6 2500 20-0,4 heavy duty for rolling mill 106 H 1 25 20 hearting transformer 500 L 3 2000 15-0,4 500 L 3 630 6,0-0,2 600 L 2 2000 34-11 700 H 1 300 0-750 rotary transformer 802 H 1 900 11-0,4 dry type for crane 600 R 2 1250 10-0,4 higly reduced losses 708 R 4 1250 11,4-22,8/04 with cubicles and fans 800 L 20 100 30-0,4 004 L 4 1600 15-0,4 nytrogen filling 710 R 2 500 11/22-0,4 803 R 1 2600 10-0,4 k 13 load factor 000 L 4 1000 15-0,4 sealed type 600 H 2 560 380-415 autotransf. for motor start 700 L 2 1000 11-0,4 900 R 4 1000 20-0,4 HV-LV encapsulated 710 R 2 1600 11-0,4 012 L 1 1250 15-0,4 600 H 2 60 400-230 910 R 4 500 13,2/400 plug in HV terminals 102 R 4 1250 22-0,4 804 R 10 315 11-0,4 resin coils 804 L 18 200 400-230 autotransf.oil cooled 300 H 17 250 380v-380v insulation transformers 600 H 2 1600 15-0,4 600 H 4 1500 400-400 low inrush current 103 L 22 2000 14-0,4 700 R 1 35 33-0,2 1phase for windgenerator 012 A C I M 967 I E 033 I I F 852 I F M 971 F 091 ELETTROMECCANICA COLOMBO Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901 T=type POWER TRANSFORMERS SYNTETIC REFERENCES H=dry type transformer R=cast resin L=liquid immersed IR AC:Internal Ref CUSTOMER Ems Pechiney All. TTR Electronic Dani Eurobox De Stefani Dani Ardry trading Siemens British Steel Min.Agric.Tun. SidiBarrak/Siba Snam Progetti CEM Viparita Coca Cola Nuova Walter Ansaldo Energia Sviluppo Sud Nuovo Pignone Ingersoll Dresser Ingersoll Dresser ABS Emit SNR Arsenale Militare Ministerio Transporte Zuccherificio Molise Helmke Italia Zarelli Ind Chimiche Saldomeccanica S.Naz.O.S T&R Group API El.pi/CocaCola Ferrari T&R Group Air Liquide ABA Kem Fruedel Ispa due Elettr. RINI ABA Lombarda Trasformatori Coca Cola Simir Eurogen Inductotherm Feralpi DNL Flowserve Stc-Atel COUNTRY Italy France Italy Italy Italy Italy Italy Italy Philippines Austria England Tunisie Italy Tunisie Argentina Uruguay Italy Italy Italy Italy Italy Italy Italy Malaysia France Italia Uruguay Italy Italy Italy Italy Italy England Italia Albania Italy England France Germany Greece Thailand Italy Italy Germany Italy Philippines Italy Italy England Italy Italy Italy Italy T L L L R L R R L L L L L L L L L L L L L L L L L L R L L L L R R R L L L R R R L R L L R L R L L L L L L L Q 4 1 1 1 2 2 1 1 2 1 1 2 1 1 3 2 1 2 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 4 1 1 16 1 1 1 1 1 1 1 1 2 11 1 1 KVA 4000 10000 6000 3000 3500 3600 4000 4000 5000 5500 7000 10000 10000 4500 5000 5000 4000 5000 19000 10000 12500 10000 4000 6500 8000 4500 5000 15000 7000 5200 4400 3300 3150 6500 8000 4000 3360 3150 3500 3500 3150 3150 7500 3150 12000 7500 10000 5600 4600 3400 3150 10000 20000 KV 10/5 42/5,5 10/6 15/0,4 12,4/2x0750 3/20,8 15/0,4 13,8/4,2 6,9/13,2 6/2x0,865 11/2x0,710 33/5,7 15/6,3 30/0,4 33/2,3 6/0,23 34,5/15 23-13,8 150-20 10,5/34,6 15,0/6 6,0/0,4 21-6,3 20-0,6 69/13,8 20/0,4 6,3/0,4 6/15 15/0,4 20/0,4 5,5/20 20/5,5 11/0,4 20/6,9 34,5/6 15/0,4 20/2x680 6/0,4 30/0,4 21/6,3 6,6/0,4 20/0,4 15/6 30/0,69 15/6 34,5/4,16 15/6 23,9/4,16 22/1,15 15/0,66 22/0,42 NOTES IR A C 910 803 904 906 for rectifiers 909 912 905 906 911 912 induction furnace 906 Powered to 12,5with fan 910 905 powered with ventilation 906 for petrol ind. 706 707 801 rewinding 803 on load tap changer 711 711 500 autotransf for motor st. 500 804 600 907 reduced losses 905 902 906 rewinding 601 500 806 806 HV-LV copper windings 901 903 diaphram conservator on load tap changer 912 907 004 709 single phase 005 autotransf. 803 fan ventilation +40% 703 909 012 011 on load tap changer 012 012 012 103 103 102 104 204 15/0,77-13.31 on load tap changer 16,33/11 205 ELETTROMECCANICA COLOMBO Società per applicazioni tecniche per la produzione e riparazione di trasformatori elettrici – fondata nel 1901 REFERENZE SINTETICHE WORLD KNOWN COMPANIES SYNTETIC REFERENCES Legenda T=type H=dry type transformer R=cast resin L=liquid immersed IR AC:Internal Ref CUSTOMER SIEMENS J.SCHNEIDER ABB KONCAR SUMITOMO KINDEN MARUBENI NIROU TRANSF HELMKE GROUP ARDRY TR FRUEDEL TRANSF & RECT. AIR LIQUIDE COCA COLA COUNTRY T A Wien L L L L R I Milano R I Milano R I Rome R I Rome R F FramatomeL D Dortmund R R India Baroda R I Sae Sadelmi I Sace L I Sace H I Mi H Cz Rep. R Singapore H R H R H JAPAN H JAPAN R JAPAN/yemeL IRAN L B L D L I R F L USA/PHILIP L L L L THAILAND R ENGLAND R France R Italy/Sv.Sud L R R Italy H Gr/Albania L Urugay L Philippines R Italy H Q 2 2 1 2 4 1 2 1 1 1 1 1 2 1 1 2 1 27 2 1 1 10 1 4 2 4 3 2 4 10 121 200 1 1 14 1 4 4 4 2 16 48 1 1 1 4 3 1 2 1 2 KVA 4500 2500 5500 2000 1500 630 800 400 250 2000 2500 2000 1600 1600 1600 1000 1600 2000 400 1250 1600 800 1000 600 1000 1200 750 1500 160 2500 KV 6/2X,0865 6/2X,0865 6/2X,0865 16-20/690 10-0,4 NOTES A C Corus Maenstaedt Steel Mill Karprum Cable car Autotr.for motor start 8,4-20/0,4 8,4-20/0,4 10/5,5 20/0,69 20/0,4 6/0,4 15/6,3 10/0,4 10/0,4 15-20/6 33/415 0,4/0,5 15/0,4 15/0,4 15/0,4 6/0,4 0,4/0,4 22/0,4 0,4/0,4 22/0,4 0,4/0,4 0,4/0,4 22/0,21 11/0,415 Prim & sec casted DMRC Pr. Primary &sec .casted Insulation transf. Insulation transf Diff power from 50 to 750 kva 50 and 100 kva 10000 22/6,3 400 60/0,4 2000 3150 5000 2500 5000 3150 14,5/0,4 34,5/0460 6,9/13,2 23,9/4,160 6,6/0,4 3000 19000 1600 3150 200 8000 5000 7500 400 10/0,480 150/20 6/0,4 6/0,4 0,4/0,4 34,5/6 6/0,23 34,5/4,16 15/0,4 diff pow up to 5000 kva hermetic type Copper windings Diff power from 400 to 6500 Kva On load tap ch. On load tap ch.