2 4 NB140 / NB200 - END CAP 03 NB140 / NB200 - WALL FIXATION INSTALLATION INSTRUCTIONS 01 NB140 - HOLE PATTERN INSTALLATION INSTRUCTIONS 01. REMOVE LID 02. PLACE END CAP 03. FASTEN SCREWS 04. PLACE LID BACK 03 01. MAKE HOLE PATTERN 02. PLACE PART A ON THE WALL 03. FASTEN SCREWS 04. PLACE PARTS B ON PART A 05. FASTEN SCREWS HALF 06. REMOVE LID 07. SLIDE PROFILE ON THE WALL FIXATION 08. FASTEN SCREWS COMPLETELY 09. PLACE LID BACK DIN911/3 04 5 10 01 Ø15 14 60 BOTTOM PROFILE NB200 - HOLE PATTERN 02 5 10 01 Ø15 14 DIN911/3 110 3 BOTTOM PROFILE 04 NB140 / NB200 - CABLE SUSPENSION 2 06 08 CEILING FIXATION 05 HOLE PATTERN - SINGLE SEE HOLE PATTERN 04 INSERT CABLE 03 ADJUST HEIGHT PART A 09 114 04 03 NB140 PART B Cut 07 170 A CENTRE OF PROFILE NB200 B IN A B C D E 5 F NB140 / NB200 - CORNERS PART A EXAMPLE: NB140 - CORNER 135° PROFILE FIXATION INSTALLATION INSTRUCTIONS 01. INSERT PARTS A (4x) IN PROFILES 02. PUT PARTS B (2x) ON TOP 03. FASTEN SCREWS INSTALLATION INSTRUCTIONS 01. REMOVE END CAP 02. PLACE CABLEHOLDERS ON CABLES 03. SLIDE CABLES IN PROFILE 04. PLACE END CAP 05. DRILL HOLES FOR CEILING FIXATION 06. PLACE CEILING FIXATION 02 01 01 PART B 01 03 DIN911/3 02 04 ACCESSORY SET ACCESSORY SET PART A 8x 1x ACCESSORY SET 7 NB200 LED ARRAY UP - ELECTRICAL CONNECTION IN PROFIEL NB200 LED ARRAY DOWN/DOWN-UP - ELECTRICAL CONNECTION IN PROFIEL 01 03 01 02 07 06 02 8 03 05 05 03 8 NB140 / NB200 - ELECTRICAL CONNECTION IN PROFIEL INSTALLATION INSTRUCTIONS 05 01. REMOVE LID 02. DRILL HOLE 03. PLACE CABLE PROTECTION 04. PLACE CABLE FIXATION 05. PLACE CABLE 06. MAKE ELECTRICAL CONNECTION 07. FIX CABLE 08. PLACE LID 03 01 02 HOLE PATTERN 02 Ø10 08 IN LID 07 04 04 230-240V L1 H07 V-U 1 - 2,5mm² N 06 10 PUSH 10 8 10 6 ACCESSORY SET 03 9 NB140 / NB200 - DIMMING ED1 : EVG DIM 1 N 240V CONTROL VOLTAGE 1-10V NB140 / NB200 - INSERT / REPLACE LAMPS INSTALLATION INSTRUCTIONS RB150 - RB250 OUTPUT N PE L 12 (BLUE) L - (BLACK) + (RED) LAMPTYPE: QR-CB51 20-35-50W 1 2 3 4 5 6 (-) DA 7 (+) DA ˜ ˜ (YELLOW/GREEN) (BROWN) 01. REMOVE LID 02. PULL FITTING 03. PULL BROKEN LAMP 04. INSERT / PLACE NEW LAMP 05. PUT LAMP INTO PLACE 06. PLACE LID INSTALLATION INSTRUCTIONS RB111 - RB211 RB311 - RB411 01 LOOSEN SCREWS 02. REMOVE BROKEN LAMP 03. INSERT / PLACE NEW LAMP 04. FASTEN SCREWS LAMPTYPE: QR-LP111 35-50W 01 01 ED2 : EVG DIM 2 for use with TOUCH-DIM OUTPUT N 240V N PE L 06 L ˜ ˜ (BROWN) (ORANGE) DIM 02 1 2 3 4 5 6 DA 7 DA (YELLOW/GREEN) TOUCH 04 MAX. 25 BALLASTS (BLUE) (WHITE) SINGLE PUSH-BUTTON FOR DIMMING LONG PUSH = DIMMING SHORT PUSH = ON/OFF 04 03 03 05 ED2 : EVG DIM 2 for use with DALI 02 OUTPUT 240V N N PE (BLUE) L L (BROWN) 1 2 3 4 5 6 DA 7 DA ˜ ˜ (YELLOW/GREEN) (ORANGE) DALI (WHITE) 1,0 0,5 INSTALLATION INSTRUCTIONS R7s UP 01. REMOVE GLASS 02. PULL ON ONE SIDE OF THE FITTING 03. REMOVE BROKEN LAMP 04. INSERT / PLACE NEW LAMP 05. PUT FITTING BACK IN PLACE 06. PLACE GLASS LAMPTYPE: QT-DE12 150W 10 NB140 / NB200 - EMERGENCY UNIT 01 01. CONNECT THE PERMANENT LIVE ( PERMANENT LIVE MUST REMAIN CONNECTED ALL THE TIME TO INSURE BATTERY'S ARE CHARGED ) 02. THE BATTERY'S MUST BE CHARGES FOR 24H WHEN THE INSTALLATION IS TAKEN IN USE 03. INDICATOR LED : - GREEN = WORKING OK - RED = ERROR INDICATION 230-240V L N 11 01 INSTALLATION INSTRUCTIONS 230-240V ! INSTALLATION INSTRUCTIONS T16 01. REMOVE BROKEN LAMP 02. INSERT / PLACE NEW LAMP LAMPTYPE: T16 / G5 DO NOT TOUCH THE LAMP WITH BARE HANDS 06 01b 02 04a 02b 01a 03 NB140 / NB200 - JACK 02a INSTALLATION INSTRUCTIONS 01. SWITCH OFF THE CURRENT 02. (RE)PLACE THE DEVICE (OPTIONAL) 03. SWITCH ON 04b 05 02 0,5 NB140 / NB200 - INSERT / REPLACE PC CLEAR UP NOBODY 140 R DEEL PARTIE TEIL PART PARTE PARTE Delta Light nv. Muizelstraat 2 B- 8560 Wevelgem (Moorsele) Belgium Phone: +32(0)56 435 735 Fax: +32(0)56 435 736 E-mail: [email protected] www.deltalight.com m 2m LID INSTALLATION INSTRUCTIONS NB140 - PROFILE 200 NB200 - PROFILE NB140 / NB200 - INSERT / REPLACE BAP 01 NB140 - PROFILE 330 00 00 = ANO / W NB200 - PROFILE 331 00 00 = ANO / W MAX. L / PROFILE : 6m +- 2,6 Kg / m MAX. L / PROFILE : 6m +- 2,9 Kg / m 01. REMOVE LID 02. REMOVE LAMP(S) AND FITTINGS 03. PLACE / REPLACE BAP 04. PLACE LAMP(S) AND FITTINGS 05. PLACE LID 02 04 03a 03b WAARSCHUWING AVERTISSEMENT WARNUNG WARNING AMMONIZIONE EDVERTENCIA ! Lees de algemene gebruiksvoorwaarden : DEEL B Lire attentivement les conditions générales d'utilisation : PARTIE B Lesen Sie die allgemeinen Gebrauchsanweisungen : TEIL B Read the general directions : PART B Leggere attentamente le condizioni generali di utilizzazione : PARTE B Leer atentamente las condiciones generales de uso : PARTE B R nv. Light le) Delta traat 2 (Moorse Muizels Wevelgem B- 8560 735 Belgium+32(0)56 435 736 Phone: 6 435 om ltalight.c Fax: +32(0)5 info@de E-mail: ltalight.com www.de aarden svoorw d’utilisation n es ne gebruik eisunge ns généralchsanw Algeme Les conditioine GebrauUse ns for de uso Die allgeme es Directio ione Generalones generaldi utilizzaz i Condicioni general Condizi DEEL PARTIE TEIL PART PARTE PARTE Installeer het armatuur enkel in ruimten waar direct contact met water onmogelijk is. Cet êquipement doit être installé dans des pièces hors de toute projection d'eau. Diese Leuchte darf nur in Räumen verwendet werden, in denen ein direkter kontakt mit wasser nicht möglich ist This fitting should only be installed in rooms where direct contact with water is impossible Este aparato solamente puede ser instalado en habitaciones donde el contacto directo con el agua sea imposible Questo apparecchio di illuminazione deve essere installato solamente in locali in cui il contatto con l'acqua è impossibile. NB140 / NB200 - PE CONNECTION NB140 / NB200 36 INSTALLATION INSTRUCTIONS 05 15 36 PC 01. BEND THE END OF THE PC 02. PLACE ON THE PROFILE 03. MAKE SURE THERE IS A GAP OF 2MM 14 144 NOBODY 200 Last update : 15/01/2004 13 0,1 WARNING !! MAKE SURE THAT THE LIDS ARE PE-PROTECTED Bevestiging plafond gependeld Montage plafond suspendu Montage decke gependelt Fixation ceiling suspended Montaje techo suspendido Montaggio soffitto sospeso ! 1 NB140 / NB200 - ACCESSORY SET Ref. : 14 330 6200 00 16 1x NB140 / NB200 - CLEANING DIN THE LUMINAIRE MUST BE SWITCHED-OFF AND COOL BEFORE BEING CLEANED. CLEANING OF LUMINAIRES: A DAMPENED SOFT CLOTH IS TO BE USED. CLEANING OF PLASTICS: USE A SOFT CLOTH AND A STANDARD pH-NEUTRAL, ALCOHOL FREE NON-SCOURING DETERGENT. CLEANING OF REFLECTORS: USE A SOFT CLOTH AND A STANDARD pH-NEUTRAL, ALCOHOL FREE NON-SCOURING DETERGENT. DELTA LIGHT® nv. BELGIUM 3 11 / 9 1x 1x 1x DIN last update : 01/07/2014 911 / 2,0 1x 1x Wijzigingen in ontwerp, technische specificaties en handleiding voorbehouden. Sous réserve de modifications au niveau de la conception, des spécifications techniques et de la notice. Änderungen von Entwurf, technischen Daten und Bedienungsanleitungen bleiben vorbehalten. Alterations in design, technical specifications and manuals reserved. El fabricante se reserva el derecho de realizar modificaciones en el diseño, las especificaciones técnicas y el folleto. Sotto riserva di modifica per quanto riguarda la concezione, le specifiche tecniche e la nota informativa.