1 UG7OG7K 2 3 4 Cavi elettrici ferroviari senza armatura per circuiti esterni degli impianti di segnalamento, controllo e sicurezza. Railway unarmoured cables, for outdoor use in signalling, control and security circuits. 1 2 3 4 – – – – Conduttore in rame stagnato rigido Classe 1/2 CEI EN 60228 Isolamento in gomma etilenpropilenica alto modulo HEPR Tipo G7 Guainetta in gomma etilenpropilenica alto modulo HEPR Tipo G7 Guaina esterna in mescola elastomerica PCP Tipo Ky NORME / STANDARDS 1 2 3 4 – – – – Rigid tin plated copper conductor class 1/2 EN 60228 Insulation HEPR rubber compound Type G7 Inner sheath HEPR rubber compound Type G7 Outer sheath PCP rubber compound Type Ky CONFEZIONAMENTO / PACKAGING RFI IS 200 D/2010 CARATTERISTICHE Colore guaina: Temperatura di esercizio: Tensione nominale: Temp. max di corto circuito: Nero -40°C ÷ +90°C sul conduttore Uo/U AC 450/750 V 250°C sul conduttore (durata max. 5 secondi) 14 x diametro esterno del cavo -25°C Raggio min. di curvatura: Temp. min. di installazione: Max sforzo di tiro durante la posa: 50 N/mm2 IMPIEGO Cavi di segnalamento e comando per l’impiego in posa fissa all’esterno ed all’interno, negli impianti ferroviari, lungo la linea e di stazione. Resistenti all’ozono, ai raggi U.V., agli oli, all’umidità ed alle intemperie. UG7OG7KNR 1 2 CHARACTERISTICS Sheath colour: Operating temperature: Rated voltage: Max temp. of short circuit: Black -40°C ÷ +90°C on the conductor Uo/U AC 450/750 V 250°C on the conductor (max duration 5 seconds) 14 x outer diameter of the cable -25°C Min bending radius: Min. installation temp.: Max laying stress during installation: 50 N/mm2 APPLICATIONS Signalling and control cables suitable for the fixed installation, outside and inside in railway plants along the lines and at stations. High resistance against ozone, U.V. rays, oils, moisture and weather proof. 3 4 5 6 ICC-RAIL Cavi elettrici ferroviari con armatura a nastri d’acciaio e guaina in PVC, per circuiti esterni degli impianti di segnalamento, controllo e sicurezza. Railway armoured cables, with steel tape armour and PVC outer sheath, for outdoor use in signalling, control and security circuits. 1 2 3 4 5 6 – – – – – – Conduttore in rame stagnato rigido Classe 1/2 CEI EN 60228 Isolamento in gomma etilenpropilenica alto modulo HEPR Tipo G7 Guainetta in gomma etilenpropilenica alto modulo HEPR Tipo G7 Guaina esterna in mescola elastomerica PCP Tipo Ky Armatura in nastri d’acciaio Guaina di protezione in PVC Tipo Rz NORME / STANDARDS 1 2 3 4 5 6 – – – – – – Rigid tin plated copper conductor class 1/2 EN 60228 Insulation HEPR rubber compound Type G7 Inner sheath HEPR rubber compound Type G7 Outer sheath PCP rubber compound Type Ky Steel tape armour Protective outer sheath PVC compound Type Rz CONFEZIONAMENTO / PACKAGING RFI IS 200 D/2010 CHARACTERISTICS Sheath colour: Operating temperature: Rated voltage: Max temp. of short circuit: Black -40°C ÷ +90°C on the conductor Uo/U AC 450/750 V 250°C on the conductor (max duration 5 seconds) 14 x outer diameter of the cable -25°C Min bending radius: Min. installation temp.: Max laying stress during installation: -40)3VCCFSDPNQPVOEUZQF.17 -40)3VCCFSDPNQPVOEUZQF(17 'MFYJCMFUJOQMBUFEDPQQFSDMBTT&/ t t t t t t t 4JOHMFDPSFDBCMFTGPSQIPUPWPMUBJDBOETPMBS TZTUFNVTF t JOTVMBUFEJOUZQFH t FMBTUPNFSJDDPNQPVOEBOEN t FMBTUPNFSJDDPNQPVOETIFBUIFE t nBNFSFUBSEBOU t IBMPHFOGSFFBOEMPXTNPLF t nFYJCMFDBCMFTGPSmYFEMBZJOH t MJGFUJNFUFTUJOH)¡D t IMPIEGO Cavi di segnalamento e comando per l’impiego in posa fissa all’esterno ed all’interno, negli impianti ferroviari, lungo la linea e di stazione. Resistenti all’ozono, ai raggi U.V., agli oli, all’umidità ed alle intemperie. APPLICATIONS Signalling and control cables suitable for the fixed installation, outside and inside in railway plants along the lines and at stations. High resistance against ozone, U.V. rays, oils, moisture and weather proof. -40)3VCCFSDPNQPVOE -40)3VCCFSDPNQPVOE 'MFYJCMFUJOQMBUFEDPQQFSDMBTT&/ t t t t t t 4JOHMFDPSFDBCMFTGPSQIPUPWPMUBJDBOETPMBS TZTUFNVTF t FMBTUPNFSJDDPNQPVOEJOTVMBUFEBOETIFBUIFE t 'MBNFSFUBSEBOU t IBMPHFOGSFF t MPXTNPLFnFYJCMFDBCMFTGPSmYFEMBZJOH t MJGFUJNFUFTUJOH)¡D t ABLE CO NC ANY MP 19 I dati e le illustrazioni della presente pubblicazione non sono impegnativi e possono essere variati a seguito di modifiche e/o perfezionamenti ritenuti opportuni dal costruttore. The data and sketches of this technical leaflet are not binding and can be varied as a consequence of modifications and/or improvements deemed necessary by the manufacturer. 50 N/mm2 61 11 50 N/mm2 A Raggio min. di curvatura: Temp. min. di installazione: Max sforzo di tiro durante la posa: Nero -40°C ÷ +90°C sul conduttore Uo/U AC 450/750 V 250°C sul conduttore (durata max. 5 secondi) 14 x diametro esterno del cavo -25°C ITALI CARATTERISTICHE Colore guaina: Temperatura di esercizio: Tensione nominale: Temp. max di corto circuito: 20 107