F4 PLUS
F4 PLUS (AS05850)
Apparecchiatura elettronica
SCHEMA ELETTRICO E COLLEGAMENTI
Electronic control unit
ELECTRICAL CONNECTIONS
I
UK
M1
M2
LAMP
LAMP
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
M1
LED
FCC M2
FCA M2
FCC M1
FCA M1
PHOTO
START
STOP
PED
SAFETY (8K2)
POWER
P.S.
TIME
DIP1
L1 L2 L3 L4 L5 L6
M3
RX
FORCE RUN
M1-M2 TIME
PED (NO)
COM
COM
ANT
F2T-160mA
L9 L10
STOP (NC)/SAF.(8K2)
COM
FCC M2 (NC)
FCA M2 (NC)
FCC M1 (NC)
FCA M1 (NC)
PHOTO (NC)
START (NO)
24Vac
0Vac
EL 12Vac
230 Vac ~ NEUTRAL
230 Vac ~ PHASE
EARTH
EARTH
230Vac
40W MAX
MOTOR
OPEN
MOTOR
COM
MOTOR
CLOSE
MOTOR
OPEN
MOTOR
COM
MOTOR
CLOSE
F1-5A
2
F4 PLUS
I-UK
SCHEMA ELETTRICO / ELECTRICAL CONNECTIONS
9
1
POWER
L11
ON
DIP2
PAUSE
ON
M4
L7 L8
M2
F4 PLUS
3
I-UK
COLLEGAMENTO ALIMENTAZIONE / POWER SUPPLY CONNECTION
2
PHASE
NEUTRAL
M2
INTERRUTTORE MAGNETOTERMICO
OVERCURRENT CIRCUIT BREAKER
230Vac
INTERRUTTORE DIFFERENZIALE
RESIDUAL-CURRENT DEVICE
PHASE
NEUTRAL
COLLEGAMENTO DI TERRA / EARTH CONNECTION
3
M2
COLLEGAMENTO LAMPEGGIANTE / FLASHING LIGHT CONNECTION
4
DIP1_9 = ON
LAMP
LAMP
OFF 9
on
off
on
off
230 Vac 40W max
M1
ON
M4
DIP2_2 = OFF
DIP1_9 = ON
LAMP
OFF
LAMP
4
ON
M1
on
off
230 Vac 40W max
on
off
F4 PLUS
4
I-UK
COLLEGAMENTO SPIA DI SEGNALAZIONE / WARNING LIGHT CONNECTION
45
ON
M4
M3
OFF 2
DIP2_2 = ON
24Vac
0Vac
24Vac 3W MAX
on
off
on
off
COLLEGAMENTO LUCE DI CORTESIA / COURTESY LIGHT CONNECTION
46
ON
OFF 9
M1
LAMP
LAMP
4
DIP1_9 = OFF
on
off
2 Min
on
off
2 Min
COLLEGAMENTO DISPOSITIVI DI COMANDO / CONTROL DEVICES CONNECTION
47
PED (NO)
COM
START (NO)
M3
COLLEGAMENTO ELETTROSERRATURA / ELECTRICAL LOCK CONNECTION
M3
0Vac
EL 12Vac
48
F4 PLUS
5
I-UK
COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION
M3
TX
RX
24Vac
0Vac
PHOTO (NC)
M1
TX
M1
M2
1 2 3 4
1 2 3
RX
M2
1 2 3 4
1 2 3
COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION
10
4
( AU01900 - AU01910 SINCRONIZZATE / SYNCHRONIZED )
M3
TX
RX
12345
1234
24Vac
0Vac
PHOTO (NC)
TX
RX
12345
1234
COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” 8K2 / 8K2 “SAFETY DEVICE” CONNECTION
ON
M3
OFF 1
11
4
DIP2_1 = ON
COM
8K2
STOP (NC)/SAF.(8K2)
8K2
COLLEGAMENTO STOP / STOP CONNECTION
M3
ON
COM
OFF 1
STOP (NC)/SAF.(8K2)
CONSULTARE IL MANUALE DELLE FOTOCELLULE PER MAGGIORI DETTAGLI / REFER TO THE PHOTOCELLS MANUAL FOR DETAILED CONNECTION DIAGRAMS
9
( AU02000 SINCRONIZZATE / SYNCHRONIZED )
4
DIP2_1 = OFF
12
31
4
F4 PLUS
6
I-UK
IMPOSTAZIONE DI DEFAULT DIP1 / DIP1 DEFAULT SETTINGS
8
MANTENIMENTO BLOCCO OLEODINAMICO DISABILITATO
HYDRAULIC BLOCK MAINTENANCE DISABLED
MORSETTI 28-29 COME LUCE DI CORTESIA
TERMINAL INPUTS N°28-29 AS COURTESY LIGHT
INGRESSO PHOTO ABILITATO / PHOTO INPUT ENABLED
FCC M2 DISABILITATO / FCC M2 DISABLED
7
FCC M2 ABILITATO / FCC M2 ENABLED
FCA M2 DISABILITATO / FCA M2 DISABLED
6
FCA M2 ABILITATO / FCA M2 ENABLED
FCC M1 DISABILITATO / FCC M1 DISABLED
5
FCC M1 ABILITATO / FCC M1 ENABLED
FCA M1 DISABILITATO / FCA M1 DISABLED
4
FCA M1 ABILITATO / FCA M1 ENABLED
COLPO D’ARIETE ABILITATO / HAMMER STROKE ENABLED
3
COLPO D’ARIETE DISABILITATO / HAMMER STROKE DISABLED
LOGICA DI FUNZIONAMENTO PASSO PASSO CON STOP
WORKING LOGIC - STEP BY STEP WITH STOP
FOTOCELLULA IN APERTURA DISABILITATA
PHOTOCELL ACTIVE DURING OPENING DISABLED
2
MANTENIMENTO BLOCCO OLEODINAMICO ABILITATO
HYDRAULIC BLOCK MAINTENANCE ENABLED
MORSETTI 28-29 COME LAMPEGGIANTE A LUCE FISSA
TERMINAL INPUTS N°28-29 AS FIXED FLASHING LIGHT
INGRESSO PHOTO DISABILITATO / PHOTO INPUT DISABLED
ON
1
LOGICA DI FUNZIONAMENTO CONDOMINIALE / WORKING LOGIC - AUTOMATIC
FOTOCELLULA IN APERTURA ABILITATA
PHOTOCELL ACTIVE DURING OPENING ENABLED
OFF
4
9 10
13
IMPOSTAZIONE DI DEFAULT DIP2 / DIP2 DEFAULT SETTINGS
14
OFF
MORSETTO M4 COME LAMPEGGIANTE / TERMINAL BLOCK M4 AS FLASHING LIGHT
MORSETTI 23 COME STOP N.C. / TERMINAL INPUT N°23 AS N.C. STOP
ON
MORSETTO M4 COME SPIA / TERMINAL BLOCK M4 AS WARNING LIGHT
MORSETTI 23 COME COSTA 8K2 / TERMINAL INPUT N°23 AS 8K2 SAFETY DEVICE
TRIMMER “FORCE”
15
31
MOVEMENT SPEED : 100% - THRUST FORCE: 25%
VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 25%
MOVEMENT SPEED : 100% - THRUST FORCE: 100%
VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 100%
F4 PLUS
7
I-UK
TRIMMER “RUN TIME”
31
16
TEMPO DI LAVORO 2 SECONDI
RUN TIME 2 SECONDS
TEMPO DI LAVORO 103 SECONDI
RUN TIME 103 SECONDS
TRIMMER “P.S. TIME”
31
17
SFASAMENTO ANTE DISABILITATO
LEAVES PHASE SHIFT TIME DISABLED
SFASAMENTO ANTA 1 IN CHIUSURA: 20 SECONDI
LEAF 1 CLOSING PHASE SHIFT TIME: 20 SECONDS
TEMPO SFASAMENTO ANTA 2 IN APERTURA: FISSO 2 SECONDI
LEAF 2 CLOSING PHASE SHIFT TIME: 2 SECONDS NOT ADJUSTABLE
TRIMMER “PAUSE”
31
18
CHIUSURA AUTOMATICA DISABILITATA
AUTOMATIC CLOSING DISABLED
PAUSA 3 SECONDI
PAUSE 3 SECONDS
TEMPO PAUSA 103 SECONDI
PAUSE 103 SECONDS
Cod. AIC8786 - 01/2015 - Rev. 00
GI.BI.DI. S.r.l.
Via Abetone Brennero, 177/B
46025 Poggio Rusco (MN) - ITALY
Tel. +39.0386.52.20.11
Fax +39.0386.52.20.31
E-mail: [email protected]
Numero Verde: 800.290156
w w w . g i b i d i . c o m
Scarica