LASTRA TERMOISOLANTE COMPOSITA PER “SISTEMI A CAPPOTTO” PLATE FOR EXTERNAL INSULATION COATING “A CAPPOTTO” SYSTEMS REXPOL STOP firex REXPOL STOP firex L’innovativa e brevettata lastra composita per “Sistemi a Cappotto” che, in caso di incendio, impedisce la propagazione delle fiamme. The innovative and patented composite plate for external insulation coating “a cappotto” systems that, in case of fire, does not allow the propagation of fire. REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating 1 2 1 Bordi perimetrali in lana minerale di spessore idoneo ad impedire totalmente la propagazione del fuoco alle lastre contigue. 1 Perimeter edges of mineral wool with thickness suitable to completely prevent the spread of fire to adjacent plates. 2 Lastra in EPS (Polistirene Espanso Sinterizzato) con la faccia esterna zigrinata per garantire una migliore adesione dei rasanti. 2 EPS (Expanded Sintered Polystyrene) plate with the outer face knurled for better adhesion of coat plasters. la propagazione del fuoco “a cappotto” systems that prevents the spread of fire 1 2 1 Bordi perimetrali in lana minerale di spessore idoneo ad impedire totalmente la propagazione del fuoco alle lastre contigue. 1 Perimeter edges of mineral wool with thickness suitable to completely prevent the spread of fire to adjacent plates. 2 Lastra in EPS (Polistirene Espanso Sinterizzato) con la faccia esterna zigrinata per garantire una migliore adesione dei rasanti. 2 EPS (Expanded Sintered Polystyrene) plate with the outer face knurled for better adhesion of coat plasters. REXPOL STOP firex Report fotografico del programma di prove Photo report of the testing program REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating Corretta applicazione del collante sulla lastra REXPOL STOP firex: la stesura avviene su tutto il perimetro della lastra e su due punti addizionali nel centro della stessa. Correct application of the adhesive on the REXPOL STOP firex plate: the layering is made on the whole perimeter of the plate and on two additional points in the centre of it. la propagazione del fuoco “a cappotto” systems that prevents the spread of fire Fasi iniziali dell’applicazione in facciata delle lastre per “Sistema a Cappotto” REXPOL STOP firex. Initial stages of the application on facade of the REXPOL STOP firex plates for exterior insulation coating “a cappotto” system. REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating La finitura della facciata è stata eseguita mediante l’applicazione di soli 4 mm di rasante con rete. The finish of the facade has been made by the application of only 4 mm of coat plaster with net. la propagazione del fuoco “a cappotto” systems that prevents the spread of fire Per riprodurre fedelmente un principio d’incendio è stato posizionato un bruciatore a gas nella zona inferiore della parete, proprio nella zona d’angolo. Sono stati necessari circa 12 minuti prima che il fuoco avesse la meglio sul rasante ed iniziasse ad interessare la lastra REXPOL STOP firex. To faithfully reproduce a fire start a gas burner has been positioned in the lower area of the wall, just in the corner area. It took about 12 minutes before the fire had the better of the coat plaster and began to affect the REXPOL STOP firex plate. REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating Trascorsi circa 12 minuti, e nonostante lo spegnimento del bruciatore a gas, la parte in Polistirene Espanso Sinterizzato della lastra REXPOL STOP firex si è completamente fusa dando vita al gocciolamento dell’EPS stesso che ha continuato ad alimentare la fiamma. After about 12 minutes, and despite turning off the gas burner, the Expanded Sintered Polystyrene of the REXPOL STOP firex plate has completely melted, creating the drip of EPS itself that has continued to fuel the flame. la propagazione del fuoco “a cappotto” systems that prevents the spread of fire Verifica dello stato della parete a incendio finito. La parete di calcestruzzo è scoppiata a causa dell’elevata temperatura; la lastra in EPS si è completamente bruciata; la crosta esterna del rasante sostenuta dalla rete è deteriorata solo nella parte interessata dal fuoco; tutto il bordo del lastra REXPOL STOP firex è perfettamente integro così come i pannelli contigui in EPS che non hanno minimamente risentito del calore sviluppatosi. Checking the status of the wall when fire is over. The wall of concrete has broken out due to the high temperature, the EPS plate is completely burned, the outer crust of coat plaster supported by the net is deteriorated only in the part affected by fire, the whole edge of the REXPOL STOP firex plate is perfectly intact as well as the adjacent panels in EPS that have not been minimally affected by the heat generated. REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating Al termine della prova, tutto il bordo della lastra per “Sistemi a Cappotto” REXPOL STOP firex è risultato perfettamente integro così come i pannelli contigui in Polistirene Espanso Sinterizzato. At the end of the test, the entire edge of the REXPOL STOP firex plate for exterior insulation coating “a cappotto” systems was perfectly intact as well as the adjacent panels in Expanded Sintered Polystyrene. la propagazione del fuoco “a cappotto” systems that prevents the spread of fire Per verificare il comportamento delle lastre REXPOL STOP firex in presenza di un incendio che si sprigionasse nella parte centrale della parete, è stato utilizzato il medesimo bruciatore a gas della sperimentazione precedente. Anche in questo caso, sono trascorsi circa 12 minuti prima che il fuoco superasse la barriera determinata dal rasante e facesse gocciolare il Polistirene Espanso Sinterizzato. To verify the behaviour of the REXPOL STOP firex plates in the presence of a fire unleashing in the central part of the wall, it has been used the same gas burner of the previous experimentation. Even in this case, about 12 minutes have passed before the fire exceeded the barrier determined by the coat plaster and made drip the Expanded Sintered Polystirene. REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating Le fiamme continuano ad alimentarsi dal gocciolamento dell’EPS fuso e dall’aria che entra dal foro provocato dalla caduta del rasante esterno del pannello coinvolto dal fuoco. The flames continue to feed on the drip of melted EPS and from the air that enters the hole caused by the fall of the outer coat plaster of the panel involved by the fire. la propagazione del fuoco “a cappotto” systems that prevents the spread of fire Ecco come si presenta la parete in calcestruzzo coibentata con le lastre per “Sistema a Cappotto” REXPOL STOP firex, dopo le due diverse simulazioni d’incendio. Here is how it looks the concrete wall insulated with the REXPOL STOP firex plates for external insulation coating “a cappotto” system after the two different simulations of fire. REXPOL Lastra per “Sistemi a Cappotto” che impedisce STOP firex Plate for external insulation coating L’obiettivo della lastra per “Sistemi a Cappotto” REXPOL STOP firex è stato raggiunto: è stato dimostrato che le fiamme sprigionate durante un incendio non si propagano alle lastre contigue per merito della parte in lana minerale che ha assolto egregiamente la sua funzione di compartimentazione. The aim of the REXPOL STOP firex plates for external insulation coating “a cappotto” system has been achieved: it has been shown that the flames emitted during a fire do not propagate to adjacent plates thanks to the part of mineral wool which has admirably fulfilled its function of partitioning. Prove superate a pieni voti! Test passed with flying colours! la propagazione del fuoco “a cappotto” systems that prevents the spread of fire STOP firex white EPS WHITE STOP firex dark NEW REXPOL 1 Supporto 4 Rasante 1 Supporto 4 Rasante 2 Collante 5 Rete in fibra di vetro 2 Collante 5 Rete in fibra di vetro 3 STOP firex white 6 Rasante 3 STOP firex dark 6 Rasante 7 Finitura 7 Finitura 1 1 4 4 3 6 2 6 5 7 5 7 STOP firex adv NEW REXPOL con trattamento superficiale 1 Supporto 4 Rasante 2 Collante 5 Rete in fibra di vetro 3 STOP firex adv 6 Rasante 2 3 STOP firex zoccolatura EPS WHITE colorato 1 Supporto 4 Rasante 2 Collante 5 Rete in fibra di vetro 3 STOP firex zoccolatura 6 Rasante 7 Finitura 7 Finitura 1 1 4 4 3 6 7 5 2 6 7 3 5 2 C 13.01 - 0615 - web via E. Fermi, 1 - 30036 Santa Maria di Sala (VE) - Italy - Tel. +39 041 486822 - Fax +39 041 486907 www.rexpolgroup.it - [email protected]