FLEXY FLEXY Chiodo endomidollare elastico in titanio e dispositivo di protezione FLEXY Intramedullary elastic titanium nail and protective cap device FLEXY In pediatric patients, fractures of the femur are the most disabling. Conservative treatment involves a long hospital stay and a long period of immobilization in a cast uncomfortable. This treatment is not well tolerated, also during the end of growth, you need a good reduction, as an erroneous consolidation is no longer correct. The elastic stable intramedullary nailing is performed with two flexible nails introduced through the metaphysis or below or through the area subtrochanteric. If performed percutaneously, this technique does not interfere with the process of bone consolidation. The elastic nails allows small movements in encouraging the consolidation of the fracture site. The reduction and stabilization are adequate and the operative risk is very low. You do not need any type of plaster cast, functional recovery is very rapid and the patient can start walking with crutches 7-10 days after surgery, depending on the type of fracture. This is a very effective technique in adolescents, which can be used from seven years of age when conservative treatment seems to be ineffective. FLEXY Nei pazienti in età pediatrica le fratture del femore sono le più invalidanti. Il trattamento conservativo implica una lunga degenza in ospedale e un lungo periodo di immobilizzazione con uno scomodo apparecchio gessato. Questo trattamento non viene ben tollerato, inoltre, nel periodo di fine crescita, è necessaria una buona riduzione, in quanto un’errata consolidazione non è correggibile in seguito. L’inchiodamento endomidollare elastico stabile si realizza con due chiodi flessibili introdotti o attraverso la metafisi inferiore o attraverso la zona subtrocanterica. Se eseguita per via percutanea, questa tecnica non interferisce con il processo di consolidamento osseo. L’elasticità dei chiodi permette piccoli movimenti nel sito della frattura, favorendone il consolidamento. La riduzione e la stabilizzazione sono sufficienti e il rischio operatorio è molto basso. Non è necessario alcun tipo di apparecchio gessato, il recupero funzionale è molto rapido e il paziente può iniziare a camminare con le stampelle 7-10 giorni dopo l’intervento, a seconda del tipo di frattura. Questa tecnica è molto efficace negli adolescenti, e può essere usata a partire dai 7 anni di età quando il trattamento conservativo sembra essere inefficace. La caratteristica biomeccanica principale del chiodo elastico Flexy è basata sull’azione simmetrica di due chiodi elastici inseriti nella metafisi, ciascuno dei quali in appoggio su tre punti. (Jean-Paul Metaizeau - pediatric hospital in Nancy - France). L’utilizzo dei chiodi endomidollari elastici garantisce i seguenti risultati: stabilità rotazionale, stabilità assiale, stabilità translazionale e stabilità alla flessione che sono le quattro proprietà per ottenere un ottimale risultato in chirurgia pediatrica. La flessibilità del chiodo elastico in titanio Flexy ne consente l’inserimento in un punto che evita interruzioni nella cartilagine di accrescimento osseo. FLEXY Main features of the Flexy elastic titanium nails is based on the symmetrical bracing action of two elastic nails inserted into the metaphysis, each of which bears against the inner bone at three points (Jean-Paul Metaizeau in the pediatric hospital in Nancy - France). The use of intramedullary elastic titanium nails provide the following results: rotational stability, axial stability, translational stability and flexural stability that all are essential for achieving optimal results in pediatric applications, the flexibility of the Flexy elastic titanium nail allows it to be inserted at a point which avoids disruption of the bone growth plate. Indicazioni Chirurgiche: Surgical Indications: Fratture dell’arto inferiore nei pazienti in età pediatrica o in pazienti di bassa statura. Alcune fratture dell’arto superiore (omero, ulna, radio) in tutti i pazienti. Lower extremity fractures in pediatric patients or in small statured patients. Certain upper extremity fractures (humerus, ulna, radius) in all patients. Contro indicazioni: Fratture instabili, fratture multiframmentarie e fratture spirali oblique. Contraindications: Unstable fractures, multifragmentary fractures and oblique spiral fractures. FLEXY Tecnica Chirurgica Surgical Technique 1) Scegliere il diametro del chiodo da 1) Choice of nail’s diameter for use. utilizzare in base alla misurazione del Measurement of the medullary canal, canale midollare nel suo punto più at the point of the narrowest diameter. stretto. Il diametro del chiodo non deve The nail diameter is no more than forty essere più del quarantapercento della percent of the width of the medullary larghezza del canale midollare. Scegliere canal. Select two nails of the same due chiodi dello stesso diametro per diameter so the opposing bendino forces ottenere identiche forze di opposizione, are equal, avoiding malalignment. per evitare errati allineamenti. FLEXY 2) Utilizzare il trocar per la preparazione del 2) Use the trocar to prepare the entry hole. foro di entrata dei chiodi. Puntare il trocar Point the trocar on the cortical bone sulla corticale sotto controllo scopico, position ed iniziare la perforazione mantenendosi perpendicular to the bone surface, 2.5 perpendicolari cm– 3.0 cm proximal to the physis. alla superficie della corticale, 3 cm circa prossimali alla fisi. with fluoroscopy and start 3) Inserire il chiodo con l’apposita guida 3) Inserting the nail maintaining the entry mantenendo il repere del foro di entrata hole with a fingertip while withdrawing the del trocar con il polpastrello. Introdurre trocar and introducing the nail. Advance manualmente il chiodo nel foro di the nail through the dril led hole by hand entrata e, con l’aiuto dell’intensificatore as far as possibile, with the fluoro scopy di brillanza, allineare la punta del chiodo use, align the nail tip so the convex side in modo che la sua parte convessa sia will glance off the far cortex. lontano dalla corticale. 4) Continuare l’inserimento del chiodo sotto 4) Advancement of the nail insertion with controllo dell’amplificatore di brillanza. fluoro scopy control. Ensure that the Assicurarsi che la parte convessa del convex side of the nail tip is glancing off chiodo sia sempre lontana dalla corticale the far cortex and is advancing with each e avanzamento blow. The nail will bend as it progresses progressivo con amplificatore di brillanza. up the canal. This part of the procedure Il chiodo si piega progredendo nel requires the greatest insertion force with canale. Questa parte della procedura hammer. controllare richiede più il suo forza, quindi utilizzare l’apposito martello. FLEXY 5) Guidare il secondo chiodo attraverso 5) Drive the second nail across the fracture la frattura nel frammento prossimale. and into the proximal fragment. Continue Continuare ad introdurre il secondo chiodo advancing this nail until it is just distal to the fino a raggiungere la fisi prossimale. proximal physis. Advance the other nail to Inserire l’altro chiodo allo stesso livello. the same level. The two nails should diverge I due chiodi devono divergere in opposte in opposite directions, both medial and direzioni sia mediali che laterali, per lateral, for optimal rotational stability. If the ottenere l’ottimale stabilità rotazionale. fracture is distracted, release traction and Se la frattura è distratta, allentare la trazione impact the patient’s heel. ed impattare il tallone del paziente. 6) Prima di tagliare il chiodo al di fuori della 6) Before cutting the nails outside of the corticale, marcare con una demografica cortex, mark the nail with a dermographic il punto di taglio a circa 15 mm al di fuori pen. retract the nail enough to access the della corticale. Ritrarre il chiodo fino a che cutoff point from outside the incision and il punto segnato dalla demografica risulti bend nail slightly. Cut the nail at the mark appena al di fuori della cute e piegarlo point. Impact the nail. leggermente. Tagliare il chiodo nel punto segnato. Impattare il chiodo. 7) Per minimizzare l’irritazione dei tessuti molli 7) For minimize soft tissue irritation and avoid ed evitare la possibile migrazione, inserire the possibile migration, insert on the end il dispositivo di protezione (a) sulla parte of the nail the protection cap device (a) terminale del chiodo stesso, della stessa of the size corresponding to the size of taglia corrispondente a quella del chiodo the nail, pressing it to the end (b), then utilizzato, premerlo fino in fondo (b), quindi tighten the “L” key (c) until his break and its avvitare (c) la chiavetta del dispositivo separation to the cap (d). di protezione fino alla rottura della stessa con la relativa separazione dal cappuccio (d). b) c) d) 8) Impattare il chiodo fino all’appoggio alla corticale del dispositivo di protezione. FLEXY a) 8) Impact the approximately nail the and will protection leave cap protruding out of the cortex. Post Operatorio Postoperative Care Per un migliore comfort del paziente, è For better patient comfort, is advisable to consigliabile utilizzare un immobilizzatore use a full-leg knee immobilizer. lungo per ginocchio. RIFERIMENTI BIBLIOGRAFICI 1) Ligier J.N., Metaizeau J.P., Prévot J. Closed flexible medulary nailing in pediatric traumatology. Chir Pediatr 1983;24(6):383-5. 2) Metaizeau J.P. L’osteosynthese chez l’enfant par embrochage centro medullaire elastique stable. Sauramps Medical, Montpellier 1988. 3) Ligier J.N., Metaizeau J.P., Prévot J., Lascombes P. Elastic stable intramedullary nailing of femoral shaft fractures in children. J Bone Joint Surg [Br] 1988;70B:74-7. al.. Titanium Elastic nails for Pediatric Femur fractures: A multicenter study of early results with analysis of complications. J Pediatr Orthop 2001;21:4-8. 5) Carey T.P., Galpin R.D. Flexible intramedullary nail fixation of pediatric femoral fractures. Clin Orthop 1996;332:110-118. 6) Wright J.G. The treatment of femoral shaft fractures in children: A systematic overview and critical appraisal of the literature. Can J Surg /J Chir Can 2000;43:180189. 7) Sanders J.O., Browne R.H., Mooney J.F., et al. Treatment of femoral fractures in children by pediatric ortho pedists: Results of a 1998 survey. J Pediatr Orthop 2001;21:436-441. 8) Erik N. Kubiak, MD, Kennet A. Egol, MD, David Scher, MD, Bradley Wasserman, PA, David Feldman, MD, Kenneth J. Koval, MD. Operative Treatment of Tibial Fractures in Children: Are Elastic Stable Intremedullary Nails Improvement Over External Fixation? The Journal of Bone and Joint Surgery (American) 84-2288-2300 (2002) FLEXY 4) Flynn J.M., Hresko T., Reynolds R.A.K., Blasier R.D., et CHIODI FLEXY / FLEXY NAILS Chiodo in lega di titanio Flexy Ø 2,0 x 450 mm / Titanium alloy nail Flexy Ø 2,0 x 450 mm 1300-200 Chiodo in lega di titanio Flexy Ø 2,5 x 450 mm / Titanium alloy nail Flexy Ø 2,5 x 450 mm 1300-250 Chiodo in lega di titanio Flexy Ø 3,0 x 450 mm / Titanium alloy nail Flexy Ø 3,0 x 450 mm 1300-300 Chiodo in lega di titanio Flexy Ø 3,5 x 450 mm / Titanium alloy nail Flexy Ø 3,5 x 450 mm 1300-350 Chiodo in lega di titanio Flexy Ø 4,0 x 450 mm / Titanium alloy nail Flexy Ø 4,0 x 450 mm 1300-400 Confezione singola NON STERILE - Single package NOT STERILE CAPPUCCIO DI PROTEZIONE PER CHIODI FLEXY / PROTECTIVE CAP FOR FLEXY NAILS 1300-20ST Protezione in lega di titanio per chiodo Flexy Ø 2,5 mm / Titanium alloy protective cap for nail Ø 2,5 mm 1300-25ST Protezione in lega di titanio per chiodo Flexy Ø 3,0 mm / Titanium alloy protective cap for nail Ø 3,0 mm 1300-30ST Protezione in lega di titanio per chiodo Flexy Ø 3,5 mm / Titanium alloy protective cap for nail Ø 3,5 mm 1300-35ST Protezione in lega di titanio per chiodo Flexy Ø 4,0 mm / Titanium alloy protective cap for nail Ø 4,0 mm 1300-40ST Confezione singola NON STERILE - Single package NOT STERILE FLEXY Protezione in lega di titanio per chiodo Flexy Ø 2,0 mm / Titanium alloy protective cap for nail Ø 2,0 mm MINI FLEXY - MINI CHIODO PER IL TRATTAMENTO DELLE FRATTURE METACARPALI E FALANGEE MINI FLEXY - MINI NAILS FOR METACARPAL AND PHALANGEAL FRACTURES TREATMENT Mini chiodo in lega di titanio Mini Flexy Ø 1,0 x 100 mm / Titanium alloy Mini Flexy mini nail Ø 1,0 x 100 mm 1200-100 Mini chiodo in lega di titanio Mini Flexy Ø 1,2 x 100 mm / Titanium alloy Mini Flexy mini nail Ø 1,2 x 100 mm 1200-120 Mini chiodo in lega di titanio Mini Flexy Ø 1,4 x 100 mm / Titanium alloy Mini Flexy mini nail Ø 1,4 x 100 mm 1200-140 Confezione da 2 pz. cadauna NON STERILE - Pack of two pieces each NOT STERILE Materiale / Material Titanio TA6V ELI - ASTM F 136 - ISO 5832-3 Titanium TA6V ELI - ASTM F 136 - ISO 5832-3 NON STERILE ! 2 Sterilizzare in autoclave prima dell’uso secondo le norme in vigore. Steam autoclave before use in accordance with the legislation in force. STRUMENTARIO / INSTRUMENTS Guida di inserimento chiodo Flexy / Flexy nail inserter Martello / Hammer 500 gr. Pinza rimozione chiodo Flexy / Flexy removal Flexy nail Trocar 3,0 mm / awl 3,0 mm Trocar 4,0 mm / awl 4,0 mm Trocar cannulato / Slotted trocar Tronchese Flexy / Flexy Cutter Impattatore finale / Final impactor Guida di inserimento chiodo Mini Flexy / Mini Flexy nail inserter Trocar piccolo per Mini Flexy / Mini Flexy Small trocar Tronchese per Mini Flexy / Mini Flexy cutter 0476 7200-0-2200 7200-0-2124 7200-0-2113 7200-0-2100 7200-0-2101 7200-0-2210 7200-0-2110 7200-0-2222 7200-0-2300 7200-0-2301 7200-0-2302 FLEXY Produttore e distributore / Manufacturer and distributor: Medical Due S.r.l. Via Trento, 43 IT-37014 Castelnuovo del Garda (VR) - Italy Tel. +39 (0) 45 6450777 - fax +39 (0) 45 6450798 www.medicaldue.it P.IVA IT-02895150239 - Reg.Imp. VR1998-63861 R.E.A. 292702 - Cap. soc. Euro 10.400,00 i.v. Rev 00_2010