Service
PARVA Recupera NOX
CIRCUITO GAS
COMPONENTI CIRCUITO GAS
TRASDUTTORE DI
PRESSIONE
Service
RECUPERATORE
BRUCIATORE
SONDA FUMI
VENTILATORE
TERMOSTATO
MASSIMA
TEMPERATURA
PARVA RECUPERA GAS
VALVOLA GAS MOD. SIT 845
•
•
Service
COMPITO
– APRIRE E CHIUDERE IL GAS
AL BRUCIATORE
– REGOLARE IL FLUSSO DEL
GAS AL BRUCIATORE
ATTRAVERSO IL MODUREG
– INTERROMPERE L’AFFLUSSO
DEL GAS AL BRUCIATORE IN
CASO DI INTERVENTO DELLE
SICUREZZE
CARATTERISTICHE
– DIMENSIONI COMPATTE
– ALIMENTAZIONE DEGLI
OPERATORI A 220 Vc.a.
– RESISTENZA EV1 DI 900 OHM
– RESISTENZA EV2 DI 6500
OHM
– RESISTENZA MODUREG DI 80
OHM
PARVA RECUPERA GAS
TARATURE GAS MODELLO “S”
•
Service
PROCEDURA TARATURA MASSIMO GAS
– VERIFICARE PRESSIONE DI RETE (sia statica che dinamica) UTILIZZANDO LA
PRESA DI PRESSIONE IN INGRESSO ALLA VALVOLA GAS
– COLLEGARE IL MANOMETRO SULLA PRESA D’ USCITA VALVOLA GAS
– POSIZIONARE LE MANOPOLE COME IN FIGURA
– ALIMENTARE ELETTRICAMENTE LA CALDAIA, SUL DISPLAY LCD COMPARE
LA SEGUENTE VISUALIZZAZIONE
– PREMERE 15 SEC. PULSANTE DI RIPRISTINO
–
–
PREMERE PIU’ VOLTE IL
PULSANTE DI RESET
PARVA RECUPERA GAS
TARATURE GAS MODELLO “S”
•
Service
PROCEDURA TARATURA MASSIMO GAS
– RUOTARE LA MANOPOLA DEL SANITARIO AL MASSIMO
– ATTIVAZIONE SPAZZACAMINO VISUALIZZABILE SUL DISPLAY LCD CON
ACCENSIONE ALTERNATA DEI SEGUENTI SIMBOLI
– LINEA T.A. CHIUSA
– PRELEVARE ABBONDANTE QUANTITA’ DI ACQUA CALDA
– TARARE LA PRESSIONE ATTRAVERSO IL DADO IN OTTONE
PARVA RECUPERA GAS
TARATURE GAS MODELLO “S”
•
Service
PROCEDURA TARATURA MINIMO GAS
– RUOTARE MANOPOLA SANITARIO AL MINIMO
– NEL DISPLAY COMPAIONO I SEGUENTI SIMBOLI
– PER TARARE LA PRESSIONE AGIRE SULLA VITE IN PLASTICA TENENDO
FERMO IL DADO IN OTTONE
– CHIUDERE RUBINETTO ACQUA E PRESA PRESSIONE
24 kw
28 kw
Min (mbar)
Max (mbar)
Min (mbar)
Max (mbar)
Metano
2,30
11,30
2,40
11,30
Butano
5,80
28,10
5,80
28,10
Propano
7,80
36,10
7,80
36,00
PARVA RECUPERA GAS
COLLETTORE GAS CON UGELLI - ELETTRODI
Service
COLLETTORE GAS CON UGELLI
• DATI BRUCIATORE
– 24 KW N° 24 RAMPE
– 28 KW N° 26 RAMPE
•
UGELLI METANO
– 24 KW = n°26 X 0,85
– 28 KW = n°30 X 0,85
• UGELLI GPL
– 26 KW = 24 X 0,50
– 28 KW = 30 X 0,51
ELETTRODI
•
COMPITO
– ELETTRODI DI ACCENSIONE : INNESCARE LA FIAMMA
SULLA MISCELA ARIA GAS
– ELETTRODO DI RIVELAZIONE: INVIARE IL SEGNALE DI
IONIZZAZIONE ALLA SCHEDA DI ACCENSIONE
•
CARATTERISTICHE
–
–
–
–
CORPO IN CERAMICA
ELETTRODO IN KANTAL
POSIZIONATI CENTRALMENTE AL BRUCIATORE
SCARICA ESEGUITA TRA DUE ELETTRODI
PARVA RECUPERA GAS
VENTILATORE - VENTURI
Service
VENTILATORE
•
COMPITO
– EVACUARE I PRODOTTI DELLA
COMBUSTIONE
•
DATI DEL MODELLO 24 KW
– MODELLO LN2 EV200
– ALIMENTAZIONE 220 VC.A.
– POTENZA:
• 24 KW = 50 W
• 28 KW = 55 W
VENTURI
•
COMPITO
– CONTROLLARE LA VELOCITA’ DEI FUMI
– CREARE UN SEGNALE DI DEPRESSIONE
•
CARATTERISTICHE
– REALIZZATO IN MATERIALE PLASTICO
– RESISTENTE A OLTRE 200°C
PARVA RECUPERA GAS
TRASDUTTORE DI PRESSIONE
•
•
Service
COMPITO
– VERIFICARE LA PORTATA FUMI IN
USCITA
– TRADUCE LA DEPRESSIONE
CREATA DAL VENTILATORE IN UN
SEGNALE ELETTRONICO E LO
COMUNICA AL CIRCUITO
INTEGRATO
CARATTERISTICHE
– COLLEGAMENTO ELETTRICO IN
BASSA TENSIONE A TRE FILI
– CONSENTE L’ACCENSIONE DEL
BRUCIATORE SOLO SE C’E’ UN
CORRETTO SEGNALE
– ALIMENTAZIONE ELETTRICA IN
BASSA TENSIONE 12Vdc
– UNICO MODELLO HUBA-CONTROL
– COLLEGATO SULLA PRESA P2 AL
VENTILATORE TRAMITE TUBI IN
SILICONE E PRESA DI PRESSIONE
PARVA RECUPERA GAS
RECUPERATORE DI CALORE E SONDA FUMI
Service
RECUPERATORE
•
COMPITO
– HA IL COMPITO DI RECUPERARE IL CALORE RESIDUO DEI FUMI
PRODOTTI DELLA COMBUSTIONE E TRASFERIRLO ALL’ACQUA CHE LO
ATTRAVERSA
CARATTERISTICHE
– REALIZZATO IN ALLUMINIO PRESSOFUSO TEFLONATO. TALE
RIVESTIMENTO GARANTISCE LA PROTEZIONE CONTRO L’ACIDITA’
DELLA CONDENSA
•
SONDA FUMI
•
COMPITO
– VERIFICARE LA TEMPERATURA FUMI IN USCITA
IMPEDENDO IL FUNZIONAMENTO DELLA CALDAIA
IN CASO SUPERINO I 120°C
PARVA RECUPERA GAS
Scarica

Parva Recupera NOX - Gas