Service PARVA Recupera NOX CIRCUITO GAS COMPONENTI CIRCUITO GAS TRASDUTTORE DI PRESSIONE Service RECUPERATORE BRUCIATORE SONDA FUMI VENTILATORE TERMOSTATO MASSIMA TEMPERATURA PARVA RECUPERA GAS VALVOLA GAS MOD. SIT 845 • • Service COMPITO – APRIRE E CHIUDERE IL GAS AL BRUCIATORE – REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE ATTRAVERSO IL MODUREG – INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE CARATTERISTICHE – DIMENSIONI COMPATTE – ALIMENTAZIONE DEGLI OPERATORI A 220 Vc.a. – RESISTENZA EV1 DI 900 OHM – RESISTENZA EV2 DI 6500 OHM – RESISTENZA MODUREG DI 80 OHM PARVA RECUPERA GAS TARATURE GAS MODELLO “S” • Service PROCEDURA TARATURA MASSIMO GAS – VERIFICARE PRESSIONE DI RETE (sia statica che dinamica) UTILIZZANDO LA PRESA DI PRESSIONE IN INGRESSO ALLA VALVOLA GAS – COLLEGARE IL MANOMETRO SULLA PRESA D’ USCITA VALVOLA GAS – POSIZIONARE LE MANOPOLE COME IN FIGURA – ALIMENTARE ELETTRICAMENTE LA CALDAIA, SUL DISPLAY LCD COMPARE LA SEGUENTE VISUALIZZAZIONE – PREMERE 15 SEC. PULSANTE DI RIPRISTINO – – PREMERE PIU’ VOLTE IL PULSANTE DI RESET PARVA RECUPERA GAS TARATURE GAS MODELLO “S” • Service PROCEDURA TARATURA MASSIMO GAS – RUOTARE LA MANOPOLA DEL SANITARIO AL MASSIMO – ATTIVAZIONE SPAZZACAMINO VISUALIZZABILE SUL DISPLAY LCD CON ACCENSIONE ALTERNATA DEI SEGUENTI SIMBOLI – LINEA T.A. CHIUSA – PRELEVARE ABBONDANTE QUANTITA’ DI ACQUA CALDA – TARARE LA PRESSIONE ATTRAVERSO IL DADO IN OTTONE PARVA RECUPERA GAS TARATURE GAS MODELLO “S” • Service PROCEDURA TARATURA MINIMO GAS – RUOTARE MANOPOLA SANITARIO AL MINIMO – NEL DISPLAY COMPAIONO I SEGUENTI SIMBOLI – PER TARARE LA PRESSIONE AGIRE SULLA VITE IN PLASTICA TENENDO FERMO IL DADO IN OTTONE – CHIUDERE RUBINETTO ACQUA E PRESA PRESSIONE 24 kw 28 kw Min (mbar) Max (mbar) Min (mbar) Max (mbar) Metano 2,30 11,30 2,40 11,30 Butano 5,80 28,10 5,80 28,10 Propano 7,80 36,10 7,80 36,00 PARVA RECUPERA GAS COLLETTORE GAS CON UGELLI - ELETTRODI Service COLLETTORE GAS CON UGELLI • DATI BRUCIATORE – 24 KW N° 24 RAMPE – 28 KW N° 26 RAMPE • UGELLI METANO – 24 KW = n°26 X 0,85 – 28 KW = n°30 X 0,85 • UGELLI GPL – 26 KW = 24 X 0,50 – 28 KW = 30 X 0,51 ELETTRODI • COMPITO – ELETTRODI DI ACCENSIONE : INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS – ELETTRODO DI RIVELAZIONE: INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA DI ACCENSIONE • CARATTERISTICHE – – – – CORPO IN CERAMICA ELETTRODO IN KANTAL POSIZIONATI CENTRALMENTE AL BRUCIATORE SCARICA ESEGUITA TRA DUE ELETTRODI PARVA RECUPERA GAS VENTILATORE - VENTURI Service VENTILATORE • COMPITO – EVACUARE I PRODOTTI DELLA COMBUSTIONE • DATI DEL MODELLO 24 KW – MODELLO LN2 EV200 – ALIMENTAZIONE 220 VC.A. – POTENZA: • 24 KW = 50 W • 28 KW = 55 W VENTURI • COMPITO – CONTROLLARE LA VELOCITA’ DEI FUMI – CREARE UN SEGNALE DI DEPRESSIONE • CARATTERISTICHE – REALIZZATO IN MATERIALE PLASTICO – RESISTENTE A OLTRE 200°C PARVA RECUPERA GAS TRASDUTTORE DI PRESSIONE • • Service COMPITO – VERIFICARE LA PORTATA FUMI IN USCITA – TRADUCE LA DEPRESSIONE CREATA DAL VENTILATORE IN UN SEGNALE ELETTRONICO E LO COMUNICA AL CIRCUITO INTEGRATO CARATTERISTICHE – COLLEGAMENTO ELETTRICO IN BASSA TENSIONE A TRE FILI – CONSENTE L’ACCENSIONE DEL BRUCIATORE SOLO SE C’E’ UN CORRETTO SEGNALE – ALIMENTAZIONE ELETTRICA IN BASSA TENSIONE 12Vdc – UNICO MODELLO HUBA-CONTROL – COLLEGATO SULLA PRESA P2 AL VENTILATORE TRAMITE TUBI IN SILICONE E PRESA DI PRESSIONE PARVA RECUPERA GAS RECUPERATORE DI CALORE E SONDA FUMI Service RECUPERATORE • COMPITO – HA IL COMPITO DI RECUPERARE IL CALORE RESIDUO DEI FUMI PRODOTTI DELLA COMBUSTIONE E TRASFERIRLO ALL’ACQUA CHE LO ATTRAVERSA CARATTERISTICHE – REALIZZATO IN ALLUMINIO PRESSOFUSO TEFLONATO. TALE RIVESTIMENTO GARANTISCE LA PROTEZIONE CONTRO L’ACIDITA’ DELLA CONDENSA • SONDA FUMI • COMPITO – VERIFICARE LA TEMPERATURA FUMI IN USCITA IMPEDENDO IL FUNZIONAMENTO DELLA CALDAIA IN CASO SUPERINO I 120°C PARVA RECUPERA GAS