Service
Parva IN
Inovia
CIRCUITO GAS
CAMERA STAGNA
VALVOLA GAS MOD. SGV 100 B&P
Service
• COMPITO
– APRIRE E CHIUDERE IL GAS AL BRUCIATORE
– REGOLARE IL FLUSSO DEL GAS AL
BRUCIATORE
– INTERROMPERE L’AFFLUSSO DEL GAS AL
BRUCIATORE IN CASO DI INTERVENTO
DELLE SICUREZZE
• CARATTERISTICHE
–
–
–
–
–
–
–
DIMENSIONI COMPATTE
PRIVA DI ORGANI MECCANICI DI TARATURA;
A BASSA RUMOROSITA’
MODELLO SGV 100 B&P
MODULATORE DA 1 a 37 mbar
TEMPERATURA -15°/ + 60°
ALIMENTAZIONE DEGLI OPERATORI A 24
Vdc.
– RESISTENZA EV1 DI 900 OHM
– RESISTENZA EV2 DI 6500 OHM
PARVA IN, INOVIA – CIRCUITO GAS
FUNZIONE SPAZZACAMINO
Service
• VERIFICA TARATURA VALVOLA GAS
– PROCEDURA PER ATTIVARE LA FUNZIONE:
– ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO
CONTEMPORANEAMENTE I TASTI A + B + C FINO A FAR APPARIRE IL
PARAMETRO “P01”;
– PREMERE IL TASTO A FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO
“P09”;
– TRAMITE IL TASTO D IMPOSTARE IL VALORE RIFERITO ALLA POTENZA ALLA
QUALE SI VUOL FAR FUNZIONARE LA CALDAIA (vedi tabella);
– PREMERE IL TASTO C PER MEMORIZZARE IL VALORE IMPOSTATO E
PROCEDERE ALLA VERIFICA.
D
A
E
B
A
D
P09 = 00
SPAZZACAMINO NON
ATTIVO - BRUCIATORE
SPENTO
P09 = 01
SPAZZACAMINO ATTIVO
BRUCIATORE ALLA
MINIMA POTENZA
P09 = 03
SPAZZACAMINO ATTIVO
BRUCIATORE ALLA
MASSIMA POTENZA
P09 = 15
SPAZZACAMINO ATTIVO
TARATURA VALVOLA
GAS
B
E
C
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MASSIMA:
• ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO
CONTEMPORANEAMENTE I SEGUENTI TASTI:
A + B + C PER 10 sec
• FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL
VALORE DEL MEDESIMO PARAMETRO
D
A
E
B
A
D
B
E
C
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MASSIMA:
• SCORRERE I PARAMETRI PREMENDO IL TASTO A FINO A FAR
APPARIRE SUL DISPLAY IL PARAMETRO P09.
D
A
E
B
A
D
B
E
C
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MASSIMA:
• VARIARE A 15 IL VALORE DEL PARAMETRO P09 PREMENDO IL
TASTO D
• MEMORIZZARE IL VALORE 15 IMPOSTATO PREMENDO IL TASTO
C
D
A
E
B
C
D
A
E
B
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MASSIMA:
• SUL DISPLAY COMPARIRA’ S-H ALTERNATO AL VALORE
ELETTRONICO DI POTENZA MASSIMA;
• VARIARE IL VALORE DEL PARAMETRO AGENDO SUL TASTO A
• VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO
DIGITALE
• SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL
MANOMETRO E’ NECESSARIO USCIRE DALLA
PROGRAMMAZIONE E RIPETERE LA PROCEDURA
D
A
E
B
D
A
E
B
1
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MASSIMA:
• CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI
RIPORTATI SUL LIBRETTO CALDAIA.
• RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN
SALITA;
• MEMORIZZARE LA TARATURA TENENDO PREMUTO IL TASTO E
FINO A CHE IL VALORE NON RIMANE FISSO.
D
A
E
B
D
A
E
B
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MINIMA:
• PER PASSARE ALLA TARATURA MINIMA PREMERE IL TASTO D
• NEL DISPLAY COMPARIRA’ LA SCRITTA S-L (taratura minima)
ALTERNATO AL VALORE ELETTRONICO DI POTENZA MINIMA
D
A
E
B
C
D
A
E
B
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MINIMA:
• VARIARE IL VALORE DI TARATURA AGENDO SUL TASTO B
• VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO
DIGITALE
• SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL
MANOMETRO E’ NECESSARIO USCIRE DALLA
PROGRAMMAZIONE E RIPETERE LA PROCEDURA
D
A
E
B
A
D
E
C
1
B
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• PROCEDURA TARATURA GAS
– TARATURA PORTATA TERMICA MINIMA:
• CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI
RIPORTATI SUL LIBRETTO CALDAIA.
• RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN
DISCESA;
• MEMORIZZARE LA TARATURA PREMENDO IL TASTO E FINO A
CHE IL VALORE NON RIMANE FISSO.
• TOGLIERE ALIMENTAZIONE ELETTRICA PER USCIRE DALLA
PROGRAMMAZIONE
D
A
E
B
C
D
A
E
B
C
PARVA IN, INOVIA – CIRCUITO GAS
TARATURE GAS
Service
• VALORI TARATURA GAS :
MODELLI
(S)
M290.24CM-24 kw
M290.28CM-28 kw
M290.32CM-32 kw
Min (mbar)
Max (mbar)
Min (mbar)
Max (mbar)
Min (mbar)
Max (mbar)
Metano
2,20
12,80
1,80
11,80
2,00
10,30
Butano
5,60
28,20
4,90
27,90
5,70
27,50
Propano
6,50
36,00
6,40
35,50
7,50
33,10
MODELLI
(A)
24 kw
28 kw
Min (mbar)
Max (mbar)
Min (mbar)
Max (mbar)
Metano
2,20
11,60
2,60
12,60
Butano
5,00
28,40
6,00
28,00
Propano
7,00
36,20
7,40
35,70
PARVA IN, INOVIA – CIRCUITO GAS
CAMBIO GAS
•
Service
PROCEDURA CAMBIO GAS (1)
A) SOSTITUIRE GLI UGGELLI AL BRUCIATORE;
B) CONFIGURARE LA SCHEDA PER IL TIPO DI GAS UTILIZZATO.
• ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMERE
CONTEMPORANEAMENTE I SEGUENTI TASTI:
• 12, 13 e 14, PER 10 sec; PER IL MODELLO PARVA IN;
•
13, 16 e 17, PER 10 sec; PER IL MODELLO INOVIA;
•
FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL
VALORE DEL MEDESIMO PARAMETRO
PARVA IN
INOVIA
PARVA IN, INOVIA – CIRCUITO GAS
CAMBIO GAS
Service
• PROCEDURA CAMBIO GAS (2)
• SCORRERE I PARAMETRI PREMENDO IL TASTO:
• 14, PER IL MODELLO PARVA IN;
• 17, PER IL MODELLO INOVIA;
• FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P05.
PARVA IN
INOVIA
PARVA IN, INOVIA – CIRCUITO GAS
CAMBIO GAS
Service
• PROCEDURA CAMBIO GAS (3)
• MODIFICARE IL VALORE DEL PARAMETRO P05 TRAMITE IL
TASTO:
– 14, PER IL MODELLO PARVA IN;
– 17, PER IL MODELLO INOVIA;
• FINO A FAR APPARIRE IL VALORE IN FUNZIONE AL TIPO DI GAS
SEGUENDO LA TABELLA SOTTO RIPORTATA:
• MEMORIZZARE IL VALORE PREMENDO IL TASTO:
– 12, PER IL MODELLO PARVA IN;
– 13, PER IL MODELLO INOVIA ;
PARVA IN, INOVIA – CIRCUITO GAS
UGELLI - ELETTRODI
Service
COLLETTORE GAS CON UGELLI
•
DATI BRUCIATORE
–
–
–
–
–
•
24CM N° 11 RAMPE
24BM N° 13 RAMPE
28CM N° 14 RAMPE
28BM N° 15 RAMPE
32CM N° 16 RAMPE
UGELLI METANO
–
–
–
–
–
24CM = n° 11 X 1,30
24BM = n° 13 X 1,25
28CM = n° 14 X 1,30
28BM = n° 15 X 1,20
32CM = n° 16 x 1,30
•
UGELLI GPL
–
–
–
–
–
24CM= 11 X 0,78
24BM= 13 X 0,75
28CM= 14 X 0,77
28 BM=15X0,75
32CM= 16 X 0,77
ELETTRODO DI ACCENSIONE E RILEVAZIONE
•
COMPITO
– ELETTRODO DI ACCENSIONE E RILEVAZIONE :
INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS ED
INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA DI
ACCENSIONE
•
CARATTERISTICHE
–
–
–
–
CORPO IN CERAMICA
ELETTRODO IN KANTAL
POSIZIONATO CENTRALMENTE AL BRUCIATORE
SCARICA ESEGUITA TRA ELETTRODO E BRUCIATORE
PARVA IN, INOVIA – CIRCUITO GAS
VENTILATORE - VENTURI
Service
• COMPITO
– EVACUARE I PRODOTTI DELLA
COMBUSTIONE
• DATI DEL MODELLO 24 KW
– MODELLO LN NATALINI
– ALIMENTAZIONE 220 VC.A.
– POTENZA:
• 24 KW = 33 W / 63 OHM
• 28 KW = 47 W / 46 OHM
• 32 KW = 60 W / 25 OHM
VENTURI
• COMPITO
– CONTROLLARE LA VELOCITA’ DEI FUMI
– CREARE UN SEGNALE DI
DEPRESSIONE
• CARATTERISTICHE
– REALIZZATO IN MATERIALE PLASTICO
(RAYTON)
– RESISTENTE A OLTRE 200°C
PARVA IN, INOVIA – CIRCUITO GAS
PRESSOSTATO FUMI
Service
• COMPITO
– VERIFICA I SEGNALI TRASMESSI DAL VENTURI
– TRADUCE IN SEGNALE ELETTRICO LA
DEPRESSIONE CREATA DAL VENTURI
– CONSENTE L’ACCENSIONE DEL BRUCIATORE
QUANDO C’E’ UNA CORRETTA DEPRESSIONE
– NON CONSENTE L’ACCENSIONE IN ASSENZA O CON
MINIMA DEPRESSIONE
– IN CASO DI ANOMALIA: E05 DISPLAY
• CARATTERISTICHE
– MODELLO HUBA CONTROLL
CIRCUITO CONTROLLO FUMI
POTENZA
CALDAIA
PRESSIONE
ON
PRESSIONE
OFF
24 KW
0,49
0,37
28 KW
1,12
0,92
32 KW
1,38
1,25
PARVA IN, INOVIA – CIRCUITO GAS
CAPPA FUMI E TERMOSTATO FUMI
Service
CAPPA FUMI (SOLO RINNOVA)
• COMPITO
– CONVOGLIA I FUMI NELLA CANNA FUMARIA
• CARATTERISTICHE
– DIAMETRO DI 130 mm
TERMOSTATO FUMI (SOLO RINNOVA)
• COMPITO
– SPEGNERE IL BRUCIATORE IN CASO DI SCARSO TIRAGGIO CANNA FUMARIA
• CARATTERISTICHE
– CONTATTO NORMALMENTE CHIUSO: SE VIENE SUPERATA LA TEMPERATURA
DI INTERVENTO IL CONTATTO SI APRE (65° C )
– TERMOSTATO A RIARMO AUTOMATICO
– INDICAZIONE DISPLAY: E05
– RIARMO CALDAIA DA PULSANTE DI SBLOCCO.
PARVA IN, INOVIA – CIRCUITO GAS
SISTEMA G.A.R.C. (SOLO INOVIA)
Service
• CARATTERISTICHE
– IL SISTEMA GARC E’ COMPOSTO DAI SEGUENTI COMPONENTI:
• SCHEDA ELETTRONICA;
• ELETTRODO DI ACCENSIONE/RILEVAZIONE
– BASA IL SUO FUNZIONAMENTO SUL SEGNALE DI RETROAZIONE (CORRENTE DI
IONIZZAZIONE) PROVENIENETE DALL’ELETTRODO DI ACCENSIONE. TALE
SEGNALE COMUNICA ALLA SCHEDA SE LA COMBUSTIONE E’ CORRETTA O MENO.
– IN CASO DI COMBUSTIONE NON CORRETTA, LA SCHEDA ESEGUE DEI
CONTROLLI, E IN BASE ALL’ANOMALIA RISCONTRATA, EVIDENZIA I SEGUENTI
ERRORI:
•
BLOCCO PER ANOMALIA COMBUSTIONE IN FUNZIONAMENTO;
PARVA IN, INOVIA – CIRCUITO GAS