TIPO VF-AS1 TYPE VF-AS1 Schema di connessione/Standard connection diagram Main circuit power supply 200 V class: 0.4 to 55 kW 75 kW *6 +DC -DC 3-phase, 200 to 240 V - 50/60 Hz 3-phase, 200 to 240 V - 50 Hz 3-phase, 200 to 240 V - 60 Hz *1 400 V class: 0.75 to 90 kW 3-phase, 380 to 480 V - 50/60 Hz 110 to 500 kW 3-phase, 380 to 440 V - 50 Hz 3-phase, 380 to 480 V - 60 Hz MCCB MC *4 PA/+ PO *7 PB *4 PC/Motor *2 R/L1 S/L2 T/L3 *5 *3 Noise filter U/T1 V/T2 W/T3 Main circuit IM Fan 400/200 V transformer (400 V class only) F R ST RES S1 S2 S3 CC TO RUN MC RO SO +SU *11 FLA Control power supply backup (optional) NC contact of overload relay ON 0-10V 0-20mA FLC RUN RUN Control circuit FLB Surge killer SOURCE OFF SINK S4 INT/PLC PLC INT SW1 From (a) FM 0-1mA P24/PLC SW2 RR/S4 RR SW4 *9 (OUT1) FM AM CCA (a) OUT1 RY OUT2 RY SW3 PLUS OUT1 Forward run signal Reverse run signal Stand by Reset Preset speed 1 Preset speed 2 Preset speed 3 Common Factory default settings *8 *10 NO LO CC *9 *9 RX VI/II RR/S4 PP (a) Voltage signal: -10 to +10 V (a) (a) Frequency meter Ammeter Ammeter or voltmeter (a) Voltage signal: 0 to 10 V or current signal: 4 (0) to 20 mA External potentiometer (or voltage signal across RR/S4-CCA terminals: 0 to 10 V input) - Prestazioni Controllo vettoriale di flusso con o senza retroazione da encoder per coppia massima motore fino al 220%. Auto-rilevazione continua delle caratteristiche motore (autotuning on-line). Rapporto di controllo velocità ad anello chiuso 1:1000, ad anello aperto 1:120. Banda passante fino a 50Hz. Frequenza di uscita fino a 1000Hz (potenze fino a 37KW, oltre 500Hz). - Opzioni integrate Tutto ciò che serve è già integrato. Filtro EMC su tutte le versioni ed induttanza DC su tutti i modelli di potenza superiore a 18.5KW. Chopper di frenatura di serie fino al modello 4160KPC (160KW). - MY FUNCTION Con MY FUNCTION I'utilizzatore può creare liberamente i propri parametri sfruttando 28 passi/programma che consentono operazioni logiche di calcolo (inclusi timer e conteggi) sullo stato degli I/0 oppure direttamente su parametri e/o variabili funzionali dell'inverter. - Funzioni speciali per le applicazioni di sollevamento VF-AS1 è la migliore soluzione per tutte le applicazioni di sollevamento. L'inverter è in grado di controllare automaticamente la velocità del motore in funzione del carico, ottimizzando l'assorbimento di corrente e controllando la coppia erogata. Inoltre VF-AS1 offre una funzione di auto-ottimizzazione del comando freno motore per partenze ed arresti sicuri in ogni condizione di carico. Nella modalità con retroazione da encoder, VF-AS1 consente il controllo in coppia, a rotore bloccato, che può essere supportato dalla modalità di posizionamento semplificato per il mantenimento della posizione attuale. -Funzioni speciali per le macchine tessili Modalità traverse ed arresto/ripartenza sincronizzata in caso di mancanza rete. Le funzioni specifiche per le macchine tessili sono di serie nel VF-AS1. - ECO-DESIGN 88% dei materiali che costituiscono il VF-AS1 sono riciclabili, più del 70% richiesto dalla normativa europea WEEE. - Performances Flux Vector control with or without encoder feedback. Maximum motor torque up to 220%. - On-line Auto-tuning. Speed control range 1000:1 in closed loop mode. Ratio 120:1 in open loop mode. High speed response frequencies up to 50Hz. Output frequency up to 1000Hz (for motor power up to 37KW, larger powers 500Hz max). - Internal options Ali that you need is inside. Built in EMC filter on all versions and DC reactor for models greater than 18.5KW. Built in regenerative braking unit up to model 4160K PC (160KW) - MY FUNCTION With MY FUNCTION the user can freely create their own functions by using 28 program steps for logic operations and calculations (including timers and counters) on I/O status or directly controlling parameters and/or Inverter's function variables. - Special features for lifting applications VF-AS1 is the best solution for all lifting applications. The light load-high speed function automatically increases the speed when operating light loads relative to the maximum lifting load to improve conveyance efficiency. Furthermore VF-AS1 offers a brake sequence function with auto learning mode which measures the braking time of the motor to achieve smooth operation at start and stop of braking operation. When using encoder feedback mode, VF-AS1 allows locked-rotor control and easy positioning mode to maintain the actual measured position. - Special functions for textile applications Traverse control and power interruption synchronized control. Specific functions for textile applications are built in to the VF-AS1 inverters. - ECO-DESIGN 88% of materials used on VF-AS1 are recyclable, which exceeds the European WEEE Directive target of 70%. 126 Fig/Pict. A Fig/Pict. B Fig/Pict. C Fig/Pict. D,E Fig/Pict. F Fig/Pict. G Fig/Pict. H Fig/Pict. I Fig/Pict.J T E N S IO N E / M O D .// VOLTAGE M ODEL 200V 400V PO TEN ZA M O TO R E/ M O T O R C A P A C IT Y KW 2004P L 0 ,4 2007P L 0 ,7 5 2015P L 1 ,5 2022P L 2 ,2 2037P L 3 ,7 W mm 130 155 5 ,5 175 7 ,5 210 11 15 2185P M 1 8 ,5 2220P M 22 2300P M 30 2370P M 37 2450P M 45 4007P L 0 ,7 5 4015P L 1 ,5 4022P L 2 ,2 4037P L 3 ,7 4055P L 5 ,5 4075P L 7 ,5 4110P L 11 4150P L 15 4185P L 1 8 ,5 4220P L 22 4300P L 30 W1 mm H1 mm F IG .// P IC T . PESO/ W E IG H T K g. N . C O D IC E / CODE 230 152 114 220 A 3 ,0 0 0 8 IM A 2 0 0 7 P L 0 0 8 IM A 2 0 1 5 P L 2055P L 2110P M D mm 0 0 8 IM A 2 0 0 4 P L 2075P L 2150P M H mm 230 260 164 138 283 190 400 191 B 4 ,0 0 0 8 IM A 2 0 2 2 P L 0 0 8 IM A 2 0 3 7 P L 158 295 249 210 386 C 5 ,5 0 0 8 IM A 2 0 5 5 P L D 7 ,0 0 0 8 IM A 2 0 7 5 P L E 9 ,0 0 0 8 IM A 2 1 1 0 P M 0 0 8 IM A 2 1 5 0 P M 240 420 212 206 403 F 2 1 ,0 0 0 8 IM A 2 1 8 5 P M 0 0 8 IM A 2 2 2 0 P M 0 0 8 IM A 2 3 0 0 P M 320 550 242 280 525 H 3 9 ,0 0 0 8 IM A 2 3 7 0 P M 0 0 8 IM A 2 4 5 0 P M 0 0 8 IT A 4 0 0 7 P L 130 230 155 260 152 114 220 A 3 ,0 138 249 B 4 ,0 C 5 ,5 D 7 0 0 8 IT A 4 0 1 5 P L 0 0 8 IT A 4 0 2 2 P L 175 164 295 210 230 240 158 283 190 40 0 191 420 212 550 242 210 206 386 0 0 8 IT A 4 0 3 7 P L 0 0 8 IT A 4 0 5 5 P L 0 0 8 IT A 4 0 7 5 P L E 0 0 8 IT A 4 1 1 0 P L 13 0 0 8 IT A 4 1 5 0 P L 15 0 0 8 IT A 4 1 8 5 P L 403 F 21 529 G 28 0 0 8 IT A 4 2 2 0 P L 0 0 8 IT A 4 3 0 0 P L 4370P L 37 0 0 8 IT A 4 3 7 0 P L 4450P L 45 0 0 8 IT A 4 4 5 0 P L 4550P L 55 4750P L 75 320 630 290 280 605 I 4 7 ,5 0 0 8 IT A 4 5 5 0 P L 0 0 8 IT A 4 7 5 0 P L 127