TIPO VF-AS1
TYPE VF-AS1
Schema di connessione/Standard connection diagram
Main circuit power supply
200 V class:
0.4 to 55 kW
75 kW
*6
+DC -DC
3-phase, 200 to 240 V - 50/60 Hz
3-phase, 200 to 240 V - 50 Hz
3-phase, 200 to 240 V - 60 Hz
*1
400 V class:
0.75 to 90 kW 3-phase, 380 to 480 V - 50/60 Hz
110 to 500 kW 3-phase, 380 to 440 V - 50 Hz
3-phase, 380 to 480 V - 60 Hz
MCCB
MC
*4
PA/+
PO
*7
PB
*4
PC/Motor
*2
R/L1
S/L2
T/L3
*5
*3
Noise
filter
U/T1
V/T2
W/T3
Main
circuit
IM
Fan
400/200 V transformer
(400 V class only)
F
R
ST
RES
S1
S2
S3
CC
TO
RUN
MC
RO
SO
+SU
*11
FLA
Control power supply
backup (optional)
NC contact of
overload relay
ON
0-10V
0-20mA
FLC
RUN
RUN
Control
circuit
FLB
Surge killer
SOURCE
OFF
SINK
S4
INT/PLC PLC INT
SW1
From (a)
FM
0-1mA
P24/PLC
SW2
RR/S4
RR
SW4
*9
(OUT1) FM AM CCA
(a)
OUT1
RY
OUT2
RY
SW3
PLUS OUT1
Forward run signal
Reverse run signal
Stand by
Reset
Preset speed 1
Preset speed 2
Preset speed 3
Common
Factory default settings
*8
*10
NO
LO
CC
*9
*9
RX VI/II RR/S4 PP
(a)
Voltage signal: -10 to +10 V
(a)
(a)
Frequency
meter
Ammeter
Ammeter or voltmeter
(a)
Voltage signal: 0 to 10 V
or current signal: 4 (0) to 20 mA
External potentiometer
(or voltage signal across RR/S4-CCA terminals:
0 to 10 V input)
- Prestazioni
Controllo vettoriale di flusso con o senza retroazione da encoder per coppia massima motore fino al 220%. Auto-rilevazione continua delle
caratteristiche motore (autotuning on-line). Rapporto di controllo velocità ad anello chiuso 1:1000, ad anello aperto 1:120. Banda passante fino
a 50Hz. Frequenza di uscita fino a 1000Hz (potenze fino a 37KW, oltre 500Hz).
- Opzioni integrate
Tutto ciò che serve è già integrato. Filtro EMC su tutte le versioni ed induttanza DC su tutti i modelli di potenza superiore a 18.5KW. Chopper di
frenatura di serie fino al modello 4160KPC (160KW).
- MY FUNCTION
Con MY FUNCTION I'utilizzatore può creare liberamente i propri parametri sfruttando 28 passi/programma che consentono operazioni logiche
di calcolo (inclusi timer e conteggi) sullo stato degli I/0 oppure direttamente su parametri e/o variabili funzionali dell'inverter.
- Funzioni speciali per le applicazioni di sollevamento
VF-AS1 è la migliore soluzione per tutte le applicazioni di sollevamento. L'inverter è in grado di controllare automaticamente la velocità del
motore in funzione del carico, ottimizzando l'assorbimento di corrente e controllando la coppia erogata. Inoltre VF-AS1 offre una funzione di
auto-ottimizzazione del comando freno motore per partenze ed arresti sicuri in ogni condizione di carico.
Nella modalità con retroazione da encoder, VF-AS1 consente il controllo in coppia, a rotore bloccato, che può essere supportato dalla modalità
di posizionamento semplificato per il mantenimento della posizione attuale.
-Funzioni speciali per le macchine tessili
Modalità traverse ed arresto/ripartenza sincronizzata in caso di mancanza rete. Le funzioni specifiche per le macchine tessili sono di serie nel
VF-AS1.
- ECO-DESIGN
88% dei materiali che costituiscono il VF-AS1 sono riciclabili, più del 70% richiesto dalla normativa europea WEEE.
- Performances
Flux Vector control with or without encoder feedback. Maximum motor torque up to 220%.
- On-line Auto-tuning.
Speed control range 1000:1 in closed loop mode. Ratio 120:1 in open loop mode. High speed response frequencies up to 50Hz. Output frequency up to 1000Hz
(for motor power up to 37KW, larger powers 500Hz max).
- Internal options
Ali that you need is inside. Built in EMC filter on all versions and DC reactor for models greater than 18.5KW. Built in regenerative braking unit up to model 4160K
PC (160KW)
- MY FUNCTION
With MY FUNCTION the user can freely create their own functions by using 28 program steps for logic operations and calculations (including timers and counters)
on I/O status or directly controlling parameters and/or Inverter's function variables.
- Special features for lifting applications
VF-AS1 is the best solution for all lifting applications. The light load-high speed function automatically increases the speed when operating light loads relative to the
maximum lifting load to improve conveyance efficiency. Furthermore VF-AS1 offers a brake sequence function with auto learning mode which measures the braking
time of the motor to achieve smooth operation at start and stop of braking operation. When using encoder feedback mode, VF-AS1 allows locked-rotor control and
easy positioning mode to maintain the actual measured position.
- Special functions for textile applications
Traverse control and power interruption synchronized control. Specific functions for textile applications are built in to the VF-AS1 inverters.
- ECO-DESIGN
88% of materials used on VF-AS1 are recyclable, which exceeds the European WEEE Directive target of 70%.
126
Fig/Pict. A
Fig/Pict. B
Fig/Pict. C
Fig/Pict. D,E
Fig/Pict. F
Fig/Pict. G
Fig/Pict. H
Fig/Pict. I
Fig/Pict.J
T E N S IO N E /
M O D .//
VOLTAGE
M ODEL
200V
400V
PO TEN ZA M O TO R E/
M O T O R C A P A C IT Y
KW
2004P L
0 ,4
2007P L
0 ,7 5
2015P L
1 ,5
2022P L
2 ,2
2037P L
3 ,7
W
mm
130
155
5 ,5
175
7 ,5
210
11
15
2185P M
1 8 ,5
2220P M
22
2300P M
30
2370P M
37
2450P M
45
4007P L
0 ,7 5
4015P L
1 ,5
4022P L
2 ,2
4037P L
3 ,7
4055P L
5 ,5
4075P L
7 ,5
4110P L
11
4150P L
15
4185P L
1 8 ,5
4220P L
22
4300P L
30
W1
mm
H1
mm
F IG .//
P IC T .
PESO/
W E IG H T
K g.
N . C O D IC E /
CODE
230
152
114
220
A
3 ,0
0 0 8 IM A 2 0 0 7 P L
0 0 8 IM A 2 0 1 5 P L
2055P L
2110P M
D
mm
0 0 8 IM A 2 0 0 4 P L
2075P L
2150P M
H
mm
230
260
164
138
283
190
400
191
B
4 ,0
0 0 8 IM A 2 0 2 2 P L
0 0 8 IM A 2 0 3 7 P L
158
295
249
210
386
C
5 ,5
0 0 8 IM A 2 0 5 5 P L
D
7 ,0
0 0 8 IM A 2 0 7 5 P L
E
9 ,0
0 0 8 IM A 2 1 1 0 P M
0 0 8 IM A 2 1 5 0 P M
240
420
212
206
403
F
2 1 ,0
0 0 8 IM A 2 1 8 5 P M
0 0 8 IM A 2 2 2 0 P M
0 0 8 IM A 2 3 0 0 P M
320
550
242
280
525
H
3 9 ,0
0 0 8 IM A 2 3 7 0 P M
0 0 8 IM A 2 4 5 0 P M
0 0 8 IT A 4 0 0 7 P L
130
230
155
260
152
114
220
A
3 ,0
138
249
B
4 ,0
C
5 ,5
D
7
0 0 8 IT A 4 0 1 5 P L
0 0 8 IT A 4 0 2 2 P L
175
164
295
210
230
240
158
283
190
40 0
191
420
212
550
242
210
206
386
0 0 8 IT A 4 0 3 7 P L
0 0 8 IT A 4 0 5 5 P L
0 0 8 IT A 4 0 7 5 P L
E
0 0 8 IT A 4 1 1 0 P L
13
0 0 8 IT A 4 1 5 0 P L
15
0 0 8 IT A 4 1 8 5 P L
403
F
21
529
G
28
0 0 8 IT A 4 2 2 0 P L
0 0 8 IT A 4 3 0 0 P L
4370P L
37
0 0 8 IT A 4 3 7 0 P L
4450P L
45
0 0 8 IT A 4 4 5 0 P L
4550P L
55
4750P L
75
320
630
290
280
605
I
4 7 ,5
0 0 8 IT A 4 5 5 0 P L
0 0 8 IT A 4 7 5 0 P L
127