Automation University 2015 AUD13 Motion Control Update Tommaso Fochi Michele Scarpulla PUBLIC PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Agenda Azionamenti con CIP Safety Drive Multiplexing Data Logging Motion Analyzer “Online” PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 2 Kinetix 5500 ERS2 CIP Safety PUBLIC PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Safety and Standard Connection (V24) Connessioni Standard e Safe con lo stesso indirizzo IP Azionamenti, Dispositivi Ethernet/IP, Robot e controllori CIP Safety con connesioni standard e safety PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 4 Controllo Standard and Safety in diverse possibili configurazioni PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 5 K5500 with Integrated Safety – ERS2 Ethernet/IP SIL3 & PLe Safe Torque Off CIP Motion Data and Safety Data Riduzione del cablaggio dei circuiti di Sicurezza Migliore modularità sia della progettazione del sistema sia delle zone di sicurezza Controlli di sicurezza gestiti dal Controllore Unico ambiente di sviluppo: Logix Designer PL-e Safe Torque Off Controller Based safety monitoring Doppia connessione Ethernet per Safety e Motion Control. Controlli e regolazioni modificabili in RunTime a seconda delle condizioni operative Diagnostica Semplicità di utilizzo: La gestione sicurezza basata sul Controllore GuardLogix migliora la flessibità del Vs. progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 6 Sicurezza Integrata su EtherNet/IP La sicurezza Integrata migliora prestazioni e flessibilità PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 7 Application Example #1: GuardLogix per Safety e Motion Control Zone 2 Zone 1 Zona 1 Zone 2 Zone 2 Zone 2 GuardLogix permette flessibilità per gestire Safety e Motion Control PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Gestione di zone di sicurezza attraverso la programmazione Zona 1 Zona 1 • • • • La gestione della sicurezza è configurata nella Safety Task del Logix designer Taglia/Incolla Assi da una zona all’altra Le connessioni Safety avvengono attraverso Ethernet/IP. Nessun cablaggio aggiuntivo è richiesto Zona 2 Zona 1 Zona 2 Zona 2 Modificare via software le zone di sicurezza in Logix PUBLIC 9 Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Application Example #2: GuardLogix per Safety e CompactLogix per Motion Zona 1 Zona 2 Zona 3 Flessibilità nella separazione di Safety e Motion Control PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Configurazione in Logix Designer Configurazione facile e completa per la sicurezza con Logix Designer PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Confronto fra Sicurezza Integrata e Sicurezza Cablata Drive Based Integrated Safety Configurazione Specifica per Dispositivo Unificata nel Controllore Set Points Fissi Programmabili, modificabili Cablaggi Necessari Ridotti o eliminati Diagnostica Limitata Dettagliata Integrazione Limitata Completamente integrata Manutenzione Elemento sostituito deve essere ricablato/riprogrammato Configurazione Automatica del dispositivo Validazione del Codice Ripetuta ogni volta Riutilizzo del codice Aumenta il valore per il cliente integrando la sicurezza nell'architettura. PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 12 5370S Compact GuardLogix Compact GuardLogix 5370 Safety Controller Il nuovo Compact GuardLogix safety controller basato su una architettura di sicurezza 1oo2 (1 out of 2): 2 Processori che ciclano il codice in parallelo. Se il risultato non è coerente il sistema viene pilotato in uno stato Safe per applicazioni di sicurezza PLe / SIL3 Stesse funzionalità di tutti gli altri controllori CompactLogix 50% memoria aggiuntiva per applicazioni di sicurezza Tre codici pianificati: L30ERMS (+0.50MB Safety Memory) L33ERMS (+1.0 MB Safety Memory) L36ERMS (+1.5 MB Safety Memory) Previsto Q4 CY2015 PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 13 Implementazione del Motion Safety LVD, MVD, Kinetix Hardwired Safety CIP Safety <V21 Kinetix 6200/6500 V21 Kinetix 5500Kinetix 5500 V24 Kinetix 5500 Kinetix 5000M Hardwired: • Safe Torque-off • Safe-Speed • SIL3 PLe Kinetix 6000 Hardwired: • Safe Torque-off • SIL2 PLd Hardwired: • Safe Torque-off • SIL3 PLe Kinetix 5700 Networked: • Safe Torque-off • SIL3 PLe PowerFlex 525 PowerFlex 750 Series PowerFlex 527 Hardwired: • Safe Torque-off • SIL2 PLd Hardwired: • Safe Torque-off • Safe-Speed • SIL3 PLe PowerFlex 7000 Networked & Hardwired • Safe Torque-off • SIL3 PLe (Network) • SIL2 PLd (Hardwired) PowerFlex 40P, 70EC, 700S/H Hardwired: • Safe Torque-off • SIL2 PLd PUBLIC Analysis of Hardwired: • Considering Safe Torque-off • Considering PL & SIL ratings Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Motion Safety Roadmap Hardwired Safety 2012 Kinetix 5500 Basic Safe Torque Off CIP Safety 2014 Kinetix 5500 Advanced CIP Safety 2015 Future VP series Motors Kinetix 5700 SIL2/PLd DSL Motor Encoder Kinetix 5500 Hardwired: • Safe Torque-off • SIL2 PLd Networked: • Safe Torque-off • SIL3 PLe Combined Networked & Hardwired • Safe Torque-off • SIL3 PLe (Network) • SIL3 PLe (Hardwired) Combine Networked & Hardwired Drive models Kinetix 5000 Family • GLX based Advanced Monitoring Functions PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. It’s Demo TIME PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 16 Drive Multiplexing PUBLIC PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 17 Logix V21 e precedenti 1 Motion Group Coarse Update Rate Attivi solo al Cambio Formato Solo 1 Coarse Update Rate Attivi ma con scarsa dinamica Sempre Attivi PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 18 V24 w/ Drive Multiplexing (Multiple Rate Selection) AX_SetUp_DS AX_SetUp_Cntr AX_SetUp_OS AX_Unw AX_GR01 AX_GR02 AX_GR03 AX_SetUp_DS AX_SetUp_Cntr AX_SetUp_OS Si possono configurare più Update Rate AX_ExConv AX_Unw AX_GR01 AX_GR02 AX_GR03 AX_ExConv Associare un CUR ad ogni funzionalità della macchina PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 19 V24 w/ Drive Multiplexing (Multiple Rate Selection) AX_Unw AX_GR01 AX_GR02 AX_GR03 PUBLIC AX_SetUp_DS AX_SetUp_Cntr AX_SetUp_OS Utilizzazione Stimata e Reale AX_ExConv Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 20 IAB Motion Performance Calculator Permette di utilizzare IAB per verificare l’applicazione Dalla versione V9.5.x.x …..Drive Multiplexing Seleziona fino a 3 CUR per progetto New V9.5.x.x PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 21 Come funziona il Multiplexing? CIP_Ax_Base_1 CIP_Ax_Base_1 CIP_Ax_Base_1 CIP_Ax_Base_1 CIP_Ax_Base_1 CIP_Ax_Base_1 CIP_Ax_Alt1_1 Virt_Ax_Alt1_2 Virt_Ax_Alt1_3 Virt_Ax_Alt1_4 Virt_Ax_Alt1_5 Virt_Ax_Alt1_6 Virt_Ax_Alt2_4 Virt_Ax_Alt2_5 Virt_Ax_Alt2_6 CIP_Ax_Alt1_1 Virt_Ax_Alt1_2 Virt_Ax_Alt1_3 Virt_Ax_Alt2_7 Virt_Ax_Alt2_8 Virt_Ax_Alt2_9 Virt_Ax_Alt1_4 Virt_Ax_Alt1_5 Virt_Ax_Alt1_6 CIP_Ax_Alt1_1 Virt_Ax_Alt1_2 Virt_Ax_Alt1_3 Virt_Ax_Alt2_4 Virt_Ax_Alt2_5 Virt_Ax_Alt2_6 Virt_Ax_Alt1_4 Virt_Ax_Alt1_5 Virt_Ax_Alt1_6 Virt_Ax_Alt2_7 Virt_Ax_Alt2_8 Virt_Ax_Alt2_9 Virt_Ax_Alt2_1 Virt_Ax_Alt2_2 Virt_Ax_Alt2_3 0msec 3msec 6msec Virt_Ax_Alt2_1 Virt_Ax_Alt2_2 Virt_Ax_Alt2_3 9msec 12msec 15msec CIP_Ax_Base_1 CIP_Ax_Alt1_1 Virt_Ax_Alt1_2 Virt_Ax_Alt1_3 Virt_Ax_Alt2_1 Virt_Ax_Alt2_2 Virt_Ax_Alt2_3 18msec Tempo (in msec) di aggiornamento della task Motion PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 22 Axis Update Status AxisUpdateStatus : Un nuovo bit di stato viene aggiunto agli attuali attributi di un asse. Il bit di AxisUpdateStatus indica quando l’istanza associata è stata aggiornata nell’ultima esecuzione della Motion Task Questo Bit viene aggiornato dal sistema per ciascun asse ad ogni esecuzione del Motion Task. Questo bit può essere utilizzato per valutare in una Task ad evento sincronizzata con il Motion Task per determinare se un asse sia stato aggiornato durante l’utlima esecuzione del Motion task Il bit di Update Status di un asse configurato nel Motion Rate Base viene impostato quando la sincronizzazione del Motion Group avviene e non cambia più valore di assegnazione PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 23 Cambiamenti nel Motion Group Attributes Il CUR è accessibile via GSV, ed anche il rapporto con i gruppi alternativi Task average scan time, Task max Scan time e Task last Scan Time sono visibili anche attraverso le proprietà del Motion Group. I tempi di scansione del Motion Task e quelli di I/O sempre del Motion Task sono visibili nella struttura del Motion Group PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 24 Gestione di Gear, Camme Elettroniche e Master Driven Speed Control con assi in Multiplexing Sebbene il concetto di Assi in Multiplexing sia pensato per discriminare fra Assi con utilizzo prevalente ed assi con utilizzo minore esiste ovviamente una larga platea di applicazioni in cui Assi a dinamica non elevata debbono essere utillizati in collegamento con Assi a dinamica elevata Gli assi Slave possono essere coordinati con Assi Master utilizzando funzioni di Gear/Pcam senza nessun rilevante scostamento indipendentemente dal gruppo di aggiornamento di appartenenza. PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 25 It’s Demo TIME PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 26 Data Logging in Kinetix 5500/5700 PUBLIC PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 27 Agenda Data Logging Overview Data Logging Parameters Data Logging AOI Application code Data Logging Timing PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 28 Data Logging Overview Descrizione Il Data Logging permette di registrare fino a 40,000 dati da Uno a Quattro variabili con un tempo di campionamento che arriva al tempo di aggiornamento degli anelli dei Drive (125µs) Questa funzione può essere utilizzata solamente via MSGs. Le istruzioni necessarie per effettuare il Data Logging dal Drive sono state raccolte in una AOI Firmware La funzione di Data Logging è presente nei Drive Kinetix 5500 dalla versione FW 2.002 PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 29 Data Logging Feature Capabilities Registra fino a 4 canali di dati. Si può accedere a tutta la lista dei dati presenti nella scelta dei Real Time Attibutes Fino a 40,000 dati per canale. Campionamento fino a 125µs. Configurazione via MSGs Benefici del Data Logging Accesso ai Dati con una precisione maggiore rispetto all’Update Rate in Logix Monitorare variabili durante la vita della macchina Sviluppare programmi di manutenzione predittiva Data logging per Gestione Predittiva e Manutenzione della Macchina PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 30 Agenda Data Logging Overview Data Logging Parameters Data Logging AOI Data Logging Timing PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 31 I Parametri del Data Logging I parametri da configurare per il data Logging sono: Impostare il numero del parametro per registrare dati in tempo reale in ognuno dei quattro canali (0, 1, 2 e 3) PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 32 I Parametri del Data Logging I parametri da configurare per il data Logging sono: 0: Valore del Segnale 1: Digitale NOTA: La funzione trigger digitale non è ancora attiva PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 33 I Parametri del Data Logging I parametri da configurare per il data Logging sono: Impostare il numero dell'attributo che verrà utilizzato come trigger per iniziare il registrazione in tutti i canali attivi (0, 1, 2 e 3) dei dati. La lista dei segnali utilizzabili come Trigger Source è limitata all'elenco degli attributi forniti successivamente. PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 34 I Parametri del Data Logging Dati Disponibili (e utilizzabili come Trigger) Attribute ID 483 460/216 367 482 844 638/262 637 527 529 522 524 553 620/266 528 530 636 801 802 806 807 635/259 523/263 521 601 600 603 602 605 606 436/131 14 02 PUBLIC Attribute Name Acceleration Feedback Acceleration Feedforward Gain Acceleration Fine Command Acceleration Reference Adaptive Tuning Gain Scaling Factor Bus Regulator Capacity Converter Capacity Current Error Current Feedback Current Limit Source Current Reference Current Vector Limit DC Bus Voltage Flux Current Error Flux Current Feedback Inverter Capacity Load Observer Acceleration Estimate Load Observer Torque Estimate Load Observer Bandwidth Load Observer Integrator Bandwidth Motor Capacity Motor Electrical Angle Operative Current Limit Output Current Output Frequency Output Power Output Voltage Converter Output Current Converter Output Power Position Error Read/Write R W R R R R R R R R R W R R R R R R W W R R R R R R R R R R Position Feedback1 R Attribute ID 365 442 437 441 443 432 431 496 504/332 505/333 843 502 841 842 492 493 491 455/135 454/134 440/215 366 462 456 461 469 453 451 Attribute Name Position Fine Command Position Integrator Bandwidth Position Integrator Output Position Loop Bandwidth Position Lock Tolerance Position Reference Position Trim System Inertia Torque Limit Negative Torque Limit Positive Torque Low Pass Filter Bandwidth Estimate Torque Low Pass Filter Bandwidth Torque Notch Filter Frequency Estimate Torque Notch Filter Magnitude Estimate Torque Reference Torque Reference Filtered Torque Trim Velocity Error Velocity Feedback Velocity Feedforward Gain Velocity Fine Command Velocity Integrator Bandwidth Velocity Integrator Output Velocity Loop Bandwidth Velocity Low Pass Filter Bandwidth Velocity Reference Velocity Trim Read/Write R W R W W R W W W W R W R R R R W R R W R W R W W R W Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 35 I Parametri del Data Logging I parametri da configurare per il data Logging sono: 0: Immediate 1: Positive Edge Trigger 2: Negative Edge Trigger 3: Greater or equal to the Trigger Level 4: Lesser or equal to the Trigger Level PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 36 I Parametri del Data Logging I parametri da configurare per il data Logging sono: Questo è il valore del segnale configurato come Trigger che innesca la registrazione dei dati. Le unità di misura dei segnali sono descritte nelle proprietà dell’asse oppure nella pubblicazione MOTION-RM003D. Esempio: Nel caso illustrato in questa slide, quando il valore effettivo del Velocity Reference (Par 453) è maggiore o uguale a 2 rev/sec, si innesca l’evento di trigger PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 37 I Parametri del Data Logging I parametri da configurare per il data Logging sono: This is the period of time between real-time data points logged in the data buffer. This Sample period must be a multiple of the loop update time of the drive. If the loop update time is 125µs, the Sample Period can be 125µs, 250µs, 375 µs , etc. PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 38 Data Logging Parameters I parametri da configurare per il data Logging sono: Questo è il numero di campioni di dati in tempo reale da registrare per ogni canale (da 1 a 4). Il numero massimo di punti dati per canale è 40.000. Tempo totale dei dati registrati: Sample Period x Capture Size Esempio: Total time = 125µs x 32000 = 4.0 sec PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 39 I Parametri del Data Logging I parametri da configurare per il data Logging sono: Questa è la percentuale del totale dei dati registrati che verranno memorizzati prima dell'evento di trigger. Esempio: • Pre-store samples = 10% • Captured size = 32000 Quindi: Ci saranno 3200 campioni registrati prima dell'evento di trigger e 28800 campioni registrati dopo l'evento di trigger. PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 40 Agenda Data Logging Overview Data Logging Parameters Data Logging AOI Data Logging Timing PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 41 Data Logging AOI Questa AOI può essere utilizzata per configurare la funzionalità di registrazione dei dati nel Drive e per copiare i dati registrati in tempo reale da tutti i canali dell’azionamento al controllore PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 42 Data Logging Tool Il Data Logging Tool è una applicazione VBA in Excel che permette di leggere e graficare I dati registrati nel drive e trasmessi al controllore. PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 43 Agenda Data Logging Overview Data Logging Parameters Data Logging AOI Data Logging Timing PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 44 Data Logging Timing Ci sono tre fasi principali del processo registrazione La divelocità di di dati in cui il tempo deve essere preso in considerazione: tempo per registrare ifra dati Drive nel drive,eil tempo per trasferire i dati trasferimento dal drive al controllore (il più lungo), e il tempo per trasferire I dati dal controllore al PC Controllore è fra misurazioni 1 e 2 al tempo coinvolti in (Opzionale). La tabella sottoindicata fornisce alcune dato questi tre passaggi. In questo test,msec il periodper di campionamento scelto è 125µs, la modalità di Trigger è Immediately, e la Pre-registrazione è del 10% dei campioni. Test Conditions Number of Data Number of Sources Samples 1000 1 5000 20000 40000 1000 2 5000 20000 40000 PUBLIC Time to Log Data in the drive 0.125 sec 0.625 sec 2.500 sec 5.000 sec 0.125 sec 0.625 sec 2.500 sec 5.000 sec Time to transfer data from the drive to the controller 2.1 sec 8.7 sec 33.6 sec 72.0 sec 3.8 sec 17.2 sec 69.7 sec 138.9 sec Time to transfer data from the controller to PC 4.0 sec 5.0 sec 8.5 sec 16.8 sec 4.9 sec 6.6 sec 17.3 sec 26.6 sec Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 45 Motion Analyzer PUBLIC PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 46 Che cosa è Motion Analyzer? Motion Analyzer è uno strumento di dimensionamento e selezione per sistemi meccatronici Motori Riduttori Azionamenti Attuatori Lineari Motion Analyzer ti aiuta a costruire una macchina migliore! PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 47 Disponibile adesso: La prossima generazione di Motion Analyzer Combina la potenza di dimensionamento di Motion Analyzer con nuove funzionalità di Ricerca e selezione dei Prodotti Un nuovo strumento rinnovato sulla base originale di Motion Analyzer Nuova interfaccia “Cloud Based” Stesso, consolidato, efficace algoritmo di dimensionamento PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Ti fornisce le informazioni necessarie Navigazione filtrabile fra i prodotti • Esplorare e confrontare le famiglie di prodotti prima di dimensionare • Verificare la compatibilità fra famiglie diverse • Possibilità di creare Liste di Materiale personalizzate Risultati di ricerca completi • • • PUBLIC Trovare L’azionamento, il motore ed il riduttore giusto, basato sui requisiti dell’ applicazione Confrontare le soluzioni con opzioni differenti di prodotti Arrivare alla soluzione utilizzando filtri sui prodotti e loro caratteristiche Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Ambiente Web & partner di terze parti forniscono nuove funzionalità e possibilità Ambiente di lavoro online collaborativo • Gli utenti possono istantaneamente condividere progetti con altri utenti • Accesso sicuro e protetto assicura che venga mantenuto il controllo dei dati • Nessuna installazione, Software sempre aggiornato Integrazione dei prodotti Encompass • I Partner Encompass Partners completano l’offerta di soluzioni di automazione complementari ai prodotti Rockwell Automation • Uno strumento per tutte le soluzioni • Permette di sfuttare al massimo le possibilità di scelta PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Le nuove funzionalità semplificano l’utilizzo di Motion Analyzer Struttura Modulare del Progetto Accesso ai progetti controllato PUBLIC Nuovo Editor dei Profili di Movimento Possibilità di inserire commenti Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Questo cosa significa per Voi? Valutare diverse opzioni all’inizio della fase di progettazione Valutare i differenti requisiti per trovare la migliore soluzione possibile La sicurezza di valutare sempre i prodotti più aggiornati sia di Rockwell Automation che dei suoi Encompass Partner Ridurre i tempi di inserimento/apprendimento dei nuovi tecnici Collaborare con tutti i componenti della vostra squadra, non importa in quale parte del mondo AiutarVi a costruire Macchine Migliori PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. It’s Demo TIME PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. 53 Available now: https://motionanalyzer.rockwellautomation.com PUBLIC www.rockwellautomation.com PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. SEMPLICE CARICO ROTATIVO Jload = 0.075 Kg*m^2 Ciclo Richiesto: Pausa 0.5 secs Movimento di 6 revs in 1 sec Pausa 0.5 secs PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un componente alla nostra libreria: Un profilo di moto rotativo PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un componente alla nostra libreria: Un profilo di moto rotativo PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un componente alla nostra libreria: Una trasmissione meccanica PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un componente alla nostra libreria: Una trasmissione meccanica PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Costruiamo il nostro primo progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Costruiamo il nostro primo progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Selezione dei Prodotti PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Selezione dei Prodotti PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un elemento Lineare Plastic Chain 15 Kgs 150 mm width 250 mm 100 mm step 25mm 50mm diameter 200 mm lenght 250 mm Aluminium Gears PUBLIC Gear Box Servo Motor Cycle: 100 mm Step in 0.3 secs + 0.4 pause Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Costruiamo un meccanismo Lineare PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Costruiamo un meccanismo Lineare PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Costruiamo un profilo di moto Lineare PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Costruiamo un profilo di moto Lineare PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un secondo asse al nostro progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Aggiungiamo un secondo asse al nostro progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Completiamo la configurazione PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Completiamo la configurazione PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Power Analisys PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Power Analisys PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Concludiamo il progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Concludiamo il progetto PUBLIC Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Automation University 2015 PUBLIC www.rockwellautomation.com PUBLIC - 5058-CO900H Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.