LNOP Durable Adhesive sensors have the following advantages that help to reduce costs: • Durability The tape material used in Masimo LNOP adhesive sensors is much more durable than that used in the competitive sensors. The result is a sensor that can be moved and reapplied multiple times during a patient's stay. Consorzio S.I.I.C. - Servizi Integrati di Ingegneria Clinica - Via Carcara, n. 6 - 16033 Lavagna (GE) Tel 800912356 - Fax 0185 314823 P. I. e C.F.01822120992 e-mail [email protected] Legge sulla Privacy : I Vostri dati esposti sul presente documento vengono utilizzati solo per fini contabili ed amministrativi nel rispetto della Legge 675/96 • • • 1 Rejuvenation Feature The adhesive used in the Masimo LNOP sensors has a unique rejuvenation feature. Using 70% isopropyl alcohol, the adhesive can be rejuvenated and the stickiness restored.1 Increased Sensor Longevity Longevity studies have been conducted and the results show a nearly twofold increase in durability with Masimo LNOP sensors compared to competitive disposable sensors. Increasing Performance Masimo LNOP sensors are uniquely designed to reduce interference from physiologic and non-physiologic noise. Unlike conventional pulse oximetry sensor design, the photodetector is recessed in a cavity that protects it from ambient light interference. The sensors are also designed to decrease the effects of electro-magnetic interference. Adtx and Pdtx cannot be rejuvenated. Masimo Adhesive Sensors Improves Performance While Reducing Cost • • • • Adhesive sensors have always had clinical advantages over reusable 'finger clip' sensors, which have made them the optimal clinical choice of caregivers. The risk of cross contamination is less likely from single-patient use adhesive sensors than from reusable sensors. For patients who are active or agitated, it is more difficult to shake off an adhesive sensor, thereby making monitoring in high motion environments more effective. Compared to reusable sensors, adhesive sensors, which decrease pressure on the monitoring site, are less prone to cause pressure necrosis. Consorzio S.I.I.C. - Servizi Integrati di Ingegneria Clinica - Via Carcara, n. 6 - 16033 Lavagna (GE) Tel 800912356 - Fax 0185 314823 P. I. e C.F.01822120992 e-mail [email protected] Legge sulla Privacy : I Vostri dati esposti sul presente documento vengono utilizzati solo per fini contabili ed amministrativi nel rispetto della Legge 675/96 Discover for yourself how Masimo adhesive sensors represent an entire 'New Evolution' in sensor technology. Neonatal LNOP® Neo LNOP Adhesive Sensors ® LNOP Neo Bridge LNOP® Neo-L ® LNOP Inf-L Pediatric Adult LNOP® Pdt LNOP® Adt LNOP® Pdtx LNOP® Adtx Consorzio S.I.I.C. - Servizi Integrati di Ingegneria Clinica - Via Carcara, n. 6 - 16033 Lavagna (GE) Tel 800912356 - Fax 0185 314823 P. I. e C.F.01822120992 e-mail [email protected] Legge sulla Privacy : I Vostri dati esposti sul presente documento vengono utilizzati solo per fini contabili ed amministrativi nel rispetto della Legge 675/96