01/2012 Mod: G77/GP7TO-N Production code: B-GPL777P DATI TECNICI – TECHNICAL DATA – DONNEES TECNIQUES TECNISHE DATE – DATOS TÉCNICO TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas (kW) G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 G20 m³/h 0,74 2X0,740 G30/31 Kg/h 0,552/0,544 2X0,552/2X0,544 Livello nominale della vasca - Nominal tank level – Niveau nominal de la cuve – Nennstand des Beckens – Nivel nominal de la cuba (l) - - Capacità vasca - Capacity tank – Capacitè cuve – Wanne faehigkeit – Capacidad cubeta (l) - - G20 mbar 20 195K 2X195K 16 180 16 2X180 (kW) 3,8 3,8 G20 mbar 20 36 2X36 G30/31 mbar 28-30/37 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A.-X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. Bruciatore pilota – Pilot burner – Brûleur pilote – Leitflamme – Quemador piloto Bruciatore principale - Main burner - Brûleur principal – Hauptbrenner – Quemador principal R.D.A.-X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/31 mbar 28-30/37 19 2x19 Country CAT/KAT GAS/GAZ G20 G30/G31 IT – IE – GR – GB – ES- PT II2H3+ p(mbar) 20 28-30/37 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas (kW) G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 G20 m³/h 0,74 2X0,740 G30/31 Kg/h 0,552/0,477 2X0,552/2X0,477 Livello nominale della vasca - Nominal tank level – Niveau nominal de la cuve – Nennstand des Beckens – Nivel nominal de la cuba (l) - - Capacità vasca - Capacity tank – Capacitè cuve – Wanne faehigkeit – Capacidad cubeta (l) - - G20 mbar 20 195K 2X195K 16 180 16 2X180 (kW) 3,8 3,8 G20 mbar 20 36 2X36 G30/31 mbar 50/50 115K 2X115K TA 85 TA 2X85 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. Xmm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. Bruciatore pilota – Pilot burner – Brûleur pilote – Leitflamme – Quemador piloto Bruciatore principale - Main burner - Brûleur principal – Hauptbrenner – Quemador principal R.D.A. Xmm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/31 mbar 50/50 19 2X19 G20 20 G30/G31 50/50 Country AT-CH CAT/KAT II2H3B/P GAS/GAZ p(mbar) I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm (kW) G20 G25 G30/31 m³/h m³/h Kg/h G20 mbar 20 – G25 mbar 25 G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 0,74 0,911 0,552/0,544 2X0,740 1,822 2X0,552/2X0,544 195K 2X195K 16 180 16 2X180 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 – G25 mbar 25 36 2X36 G30/31 mbar 28-30/37 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner - Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/31 mbar 28-30/37 19 2x19 Country CAT/KAT GAS/GAZ G20/G25 G30/G31 BE – FR II2E+3+ p(mbar) 20/25 28-30/37 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm (kW) G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 G20 m³/h 0,74 2X0,740 G30/31 Kg/h 0,552/0,477 2X0,552/2X0,477 195K 2X195K 16 180 16 2X180 G20 mbar 20 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 36 2X36 G30/31 mbar 30/30 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner - Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/31 mbar 30/30 19 19X2 Country CAT/KAT GAS/GAZ G20 G30/G31 NO-EE-LT-SK-SI-TR-HR-RO-CZ-MK-AL-IS-DK-FI-SE-BG II2H3B/P p(mbar) 20 30/30 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm (kW) G20 G25 G30/31 m³/h m³/h Kg/h G20 mbar 20 G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 0,74 0,862 0,552/0,477 2X0,740 2X0,862 2X0,552/2X0,477 195K 2X195K 16 180 16 2X180 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 36 2X36 G25 mbar 20 215K 2X215K 16 180R 16 2X180R Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G25 mbar 20 36 2X36 G30/31 mbar 50/50 115K 2X115K TA 85 TA 2X85 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/31 mbar 50/50 19 2X19 G20 G25 G30/G31 20 20 50/50 Country CAT/KAT DE II2ELL/3B/P GAS/GAZ p(mbar) I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas (kW) G25 G31 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm m³/h Kg/h G25 mbar 25 G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 0,862 0,552/0,544 2X0,862 2X0,552/2X0,544 205K 2X205K 16 180 16 2X180 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G25 mbar 25 36 2X36 G31 mbar 37 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G31 mbar 37 19 2X19 G31 mbar 50 120K 2X120K TA 85 TA 2X85 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G31 mbar 50 19 2X19 Country CAT/KAT GAS/GAZ G25 G31 G31 NL II2L3P p(mbar) 25 37 50 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas (kW) G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 G20 m³/h 0,74 2X0,740 G31 Kg/h 0,544 2X0,544 195K 2X195K 16 180 16 2X180 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm G20 mbar 20 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 36 2X36 G31 mbar 37 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G31 mbar 37 19 2X19 G31 mbar 50 120K 2X120K TA 85 TA 2X85 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G31 mbar 50 19 2X19 Country CAT/KAT GAS/GAZ G20 G31 G31 LU II2E3P p(mbar) 20 37 50 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal (kW) G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 G20 m³/h 0,74 2X0,740 G31 Kg/h 0,544 2X0,544 195K 2X195K R.D.A. X mm 16 16 BY PASS-Ø-1/100mm 180 2X180 Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal G20 mbar 20 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 36 2X36 G31 mbar 37 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G31 mbar 37 19 2X19 Country CAT/KAT GAS/GAZ G20 G31 PL II2E3P p(mbar) 20 37 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas (kW) G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 G20 m³/h 0,74 2X0,740 G30/G31 Kg/h 0,552/0,544 2X0,552/2X0,544 195K 2X195K 16 180 16 2X180 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm G20 mbar 20 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 36 2X36 G30/31 mbar 28-30/37 135K 2X135K TA 100 TA 2X100 Bruciatore principale - Main burner - Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/31 mbar 28-30/37 19 2x19 G30/G31 mbar 50/67 115K 4X90K TA 85 TA 2X85 Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. X mm BY PASS-Ø-1/100mm Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/G31 mbar 50/67 19 2X19 G20 G30/G31 G30/G31 20 28-30/37 50/67 Country CAT/KAT PT II2H3+ GAS/GAZ p(mbar) I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. Xmm BY PASS-Ø-1/100mm (kW) G30/G31 Kg/h G30/G31 mbar30/30 G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 0,552/0,477 2X0,552/2X0,477 135K 2X135K TA 100 TA 2X100 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3 3 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G30/G31 mbar30/30 19 2X19 Country MT-CY CAT/KAT I3B/P GAS/GAZ p(mbar) G30/G31 30/30 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire TA:Tutto aperto-opened-Tout ouvert-Alles offen-Todo abierto TABELLA II-TABLEAU II-TABLE II-TABELLE II-TABLAII Dati tecnici – Technical data – Donnees tecniques – Tecnishe date – Datostécnicos Modelli – Models – Modèles – Modelle – Modelos Tipo – Type – Bauart Potenza nominale – Nominal thermal power – Puissance thermique nominale – NominalWärmeleistung – Potencia tèrmica nominal Consumo gas – Gas consumption – Consommation de gaz – Gasverbrauch Consumición del gas Bruciatore principale - Main burner – Brûleur principal – Hauptbrenner – Quemador principal R.D.A. Xmm BY PASS Ø-1/100mm (kW) G20 m³/h G20 mbar 20 G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O A1 A1 7 7+7 0,74 2X0,740 195K 2X195K 16 180 16 2X180 Potenza ridotta – Reduced power – Puissance thermique reduite – Verringerte leistung – Potencia tèrmica reduita. (kW) 3,8 3,8 Bruciatore pilota - Pilot burner - Brûleur pilote – Leitflamme – Quemador piloto G20 mbar 20 36 2X36 Country LV CAT/KAT I2H GAS/GAZ p(mbar) G20 20 I diametri degli ugelli sono espressi in 1/100mm – The diameter of the nozzles are indicated in 1/100mm Le diamètres des gicleur sont exprimés en 1/100mm Diameter der Düsen ist in 1/100mm angegeben – Los diámetros de las boquillas se indican en 1/100mm RDA:Regolazione dell' aria primaria ; Regulation of primary air;Réglage del'air primaire ; Primärlufteinstellung ; Regulación de la entrada del aire SCHEMI DI INSTALLAZIONE INSTALLATION DIAGRAMS SCHEMAS D’INSTALLATION INSTALLATIONSPLÄNE ESQUEMAS DE INSTALACIÓN Ø 17mm H=15/20 mm Ø 17mm H=15/20 mm G77/GP4T-V G77/GP4T-O G77/GP7T-V G77/GP7T-O G) Attacco gas G 1/2” Gas connection G 1/2” Raccord gaz G 1/2” Gasanschluß G 1/2" Toma de gas G 1/2”