MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE IT MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE INDICE Tav_1 DISASSEMBLAGGIO POMPE SERIE BLUE Apertura parte idraulica ............................................................................................................ 3 Apertura pozzetto d’olio............................................................................................................6 Estrazione tenute meccaniche...................................................................................................8 Smontaggio cuscinetti albero .................................................................................................. 10 Apertura maniglia / vano elettrico .......................................................................................... 10 Smontaggio valvola sfiato ....................................................................................................... 15 Estrazione statore................................................................................................................... 16 IT IT ASSEMBLAGGIO POMPE SERIE BLUE Preparazione albero motore .................................................................................................... 18 Parte fissa tenute meccaniche................................................................................................. 18 Inserimento statore ................................................................................................................ 19 Inserimento albero motore ..................................................................................................... 20 Parte mobile tenute meccaniche ............................................................................................. 20 Chiusura pozzetto olio ............................................................................................................ 22 Riempimento pozzetto olio...................................................................................................... 22 Montaggio valvola di sfiato ..................................................................................................... 24 Parte idraulica ........................................................................................................................ 25 Maniglia .................................................................................................................................. 27 2 Pag. 2 www.zenit.com Apertura parte idraulica 1: Svitare le viti della griglia di aspirazione / piede di supporto con un giravite a croce. www.zenit.com 3 Pag. 3 MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_2 Tav_4 IT IT 2: Sfilare il piede di supporto / griglia di aspirazione e l’ORing. Nelle versioni DG professional sfilare anche la flangia di protezione. Standard Standard 4: Svitare la vite della girante con un giravite a croce bloccando la girante (ad esempio, con una pinza) e sfilare la girante. Professional Tav_3 Professional Tav_5 3: Svitare le viti della flangia di aspirazione con un giravite a croce. Sfilare la flangia di aspirazione e l’ORing. 4 Pag. 4 www.zenit.com 5: Riavvitare la vite della girante sull’albero con un giravite a croce per 6/8 giri. Questa operazione non è necessaria per le versioni Professional www.zenit.com 5 Pag. 5 MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_8 Tav_6 VERTIC SX Apertura pozzetto d’olio 6: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Svitare la flangia del pozzetto olio fino a toccare la bussola esagonale in bronzo, utilizzare una chiave a bussola 30mm. Assicurarsi che la flangia sia completamente libera. IT VERTIC 8:ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Rimuovere la vite e la bussola esagonale in bronzo. Questa operazione non è necessaria per le versioni Professional ATTENZIONE! Ruotare in senso orario: la filettatura è sinistrorsa! Questa operazione non è necessaria per le versioni Professional Tav_7 VERTIC Tav_9 7: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Con un martello in gomma colpire leggermente la testa della vite sull’albero per liberare la bussola esagonale in bronzo dall’estremità conica dell’albero. VERTIC Questa operazione non è necessaria per le versioni Professional 6 Pag. 6 www.zenit.com 9:ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Svitare completamente la flangia del pozzetto olio e sollevarla sfilandola dall’albero. ATTENZIONE! Ruotare in senso orario: la filettatura è sinistrorsa. www.zenit.com 7 Pag. 7 IT MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_13 Tav_10 VERTIC Tav_12 10: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Aspirare l’olio contenuto nel pozzetto. 12: Estrarre il gruppo alberosupporto cuscinetto inferiore dal gruppo motore. IT IT 13: Svitare la vite della girante con un giravite a croce, rimuovere la rondella / bussola esagonale, rimuovere dall’albero le parti rotanti, la molla, l’O-ring e la cuffia in gomma se rimasta sul cuscinetto. Tav_11 VERTIC Estrazione tenute meccaniche 11: Avvitare la vite della girante sull’albero con un giravite a croce posizionando sotto la testa della stessa una rondella o se non possibile la bussola esagonale in bronzo capovolgendola rispetto il normale utilizzo. Posizionare due leve sotto la rondella / bussola per esercitare una forza sufficiente a liberare il gruppo albero. Tav_15 Tav_14 14: Con un martello in gomma colpire leggermente l’estremità conica dell’albero tenendo appoggiato al banco il supporto cuscinetto inferiore. 15: Rimuovere dal supporto cuscinetto inferiore l’albero e la controfaccia della tenuta tramite un giravite dalla parte posteriore. VERTIC 8 Pag. 8 www.zenit.com www.zenit.com 9 Pag. 9 MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_19 Tav_16 Smontaggio cuscinetti albero 16: Con un estrattore rimuovere il cuscinetto superiore dall’albero. Tav_17 17: Con un estrattore rimuovere il cuscinetto inferiore dall’albero avendo cura di proteggere l’estremità conica dello stesso. IT IT Tav_18 19: Sollevare la maniglia dall’impugnatura verso l’alto tenendo fermo il gruppo motore. Apertura maniglia / vano elettrico 18: Svitare le viti della maniglia con giravite a croce. 10 Pag. 10 www.zenit.com www.zenit.com 11 Pag. 11 MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_20 Tav_21 21: Svitare la vite della terra con un giravite a croce. IT 20: Estrarre i componenti interni tirando i cavi elettrici verso l’alto. Annotare su un foglio il colore dei collegamenti elettrici. Sono comunque disponibili diagrammi per ogni tipo di pompa. Tagliare i collegamenti elettrici in corrispondenza dei connettori. Tav_22 22: Sfilare dal vano il condensatore quando presente. 12 Pag. 12 www.zenit.com www.zenit.com 13 Pag. 13 IT MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_24 Tav_23 IT IT Smontaggio valvola sfiato 24: Con apposita chiave svitare il tappo in plastica della valvola ed estrarre la sfera in gomma. 23: Sfilare i componenti dai cavi elettrici. 14 Pag. 14 www.zenit.com www.zenit.com Pag.1515 MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE DISASSEMBLAGGIO POMPE SERIE BLUE Tav_25 DISASSEMBLAGGIO POMPE SERIE BLUE Tav_26 Tav_27 Tav_28 Rimuovere i cavi in uscita dallo statore sfilandoli dall’alloggio condensatore e posizionarli all’ interno del tampone Estrazione statore 25: inserire l’apposito attrezzo estrattore di fornitura Zenit all’interno dello statore. 27:Inserire lungo la barra filettata dell’attrezzo estrattore il distanziale per estrazione statore e avvitare il dado M20 ingrassando precedentemente il filetto IT 26: Serrare il dado con una chiave a forchetta 30mm in senso orario fino a completa espansione dell’attrezzo. 28: Avvitare in senso orario il dado con una chiave a forchetta 30mm fino a completa estrazione dello statore. Tav_29 29: Rimuovere lo statore e gli attrezzi. Pulire accuratamente la carcassa per poi poter procedere al montaggio. FINE DISASSEMBLAGGIO 16 Pag. 16 www.zenit.com www.zenit.com 17 Pag. 17 IT ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE ASSEMBLAGGIO POMPE SERIE BLUE Tav_1a Øi 13 mm MIN Øe 18 mm MAX Tav_2a Tav_4a Øi 13 mm MIN Øe 18 mm MAX 4a: Inserire l’albero pre-assemblato nel foro del supporto cuscinetto inferiore facendo attenzione a non toccare la controfaccia. Portare a battuta il cuscinetto nella sua sede utilizzando, con cautela, un martelletto. Preparazione albero motore 1a:Inserire il cuscinetto inferiore utilizzando un tubo in acciaio del diametro esterno max 18 mm spessore 2.5 max. E’ consigliato l’uso di una piccola pressa o di un martello. IT STOP STOP 2a: Inserire il cuscinetto superiore utilizzando un tubo in acciaio del diametro esterno max 18 mm spessore 2.5 max. E’ consigliato l’uso di una piccola pressa o di un martello. Tav_5a Inserimento statore Tav_3a 5a: Inserire lo statore nella carcassa utilizzando gli appostiti attrezzi (vedi disegno) fino al raggiungimento della battuta sul tampone. Per l’inserimento dello statore si utilizzerà una pressa da max. 8 Ton. Tav_3a_1 Parte fissa tenute meccaniche 3a: Inserire la controfaccia in Grafite Allumina della tenuta meccanica nella sede del supporto cuscinetto inferiore utilizzando l’apposito tampone in Nylon. ATTENZIONE! Orientare l’uscita cavi dello statore come in figura in corrispondenza della sede del condensatore. 3a_1: Inserire la controfaccia in Carburo di Silicio della tenuta meccanica nella sede della flangia del pozzetto olio utilizzando l’apposito tampone in Nylon. 18 www.zenit.com www.zenit.com 19 IT ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE Tav_8a Tav_6a 8a: Inserire sull’albero la molla della tenuta meccanica calzandola sul collarino della tenuta meccanica sottostante. Inserimento albero motore IT POMPE SERIE BLUE IT 6a: Inserire la cuffia in gomma sul cuscinetto superiore. Inserire il corpo albero-supporto cuscinetto inferiore nella carcassa esercitando pressione con le mani. Tav_9a Tav_7a 9a: Inserire sull’albero la parte rotante della tenuta meccanica (Carburo di Silicio) utilizzando l’apposito tampone in Nylon fino alla battuta Parte mobile tenute meccaniche 7a: Inserire sull’albero la parte rotante della tenuta meccanica (in grafite allumina) utilizzando l’apposito tampone in Nylon fino alla battuta. ATTENZIONE! Controllare la pulizia e il verso della parte a contatto! ATTENZIONE! Controllare la pulizia e il verso della parte a contatto! 20 www.zenit.com www.zenit.com 21 ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE ASSEMBLAGGIO POMPE SERIE BLUE Tav_12a Tav_10a VERTIC + OIL VERTIC Chiusura pozzetto olio 10a: ATTENZIONE! Mantenere la pompa in posizione VERTICALE. Appoggiare l’O-ring NUOVO nella sede. IT 12a: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Con un pennello a setole morbide lubrificare leggermente l’O-ring con olio CASTROL PRODUCT L 320. Tav_13a Tav_11a Riempimento pozzetto olio VERTIC 11a: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Riempire il pozzetto con olio CASTROL PRODUCT L 320 fino a coprire i pioli come in figura. 13a: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Avvicinare il gruppo flangiacontrofaccia al motore facendo attenzione a non urtare la controflangia. Avvitare dapprima con le mani la flangia del pozzetto olio in modo da abboccare il filetto. ATTENZIONE! Ruotare in senso antiorario: la filettatura è sinistrorsa. E’ indispensabile l’assoluta pulizia delle parti componenti la tenuta meccanica. VERTIC 22 www.zenit.com www.zenit.com 23 IT ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE Tav_16a Tav_14a VERTIC ASSEMBLAGGIO POMPE SERIE BLUE SX 14a: ATTENZIONE! Mantenere la pompa in posizione VERTICALE per evitare fuoriuscite di olio. Serrare a fondo la flangia pozzetto olio con una chiave a bussola da 30mm e una coppia max di 100 Nm. ATTENZIONE! Ruotare in senso antiorario: la filettatura è sinistrorsa. IT 16a: con apposita chiave serrare a fondo la boccola in plastica. Tav_15a Tav_17a Montaggio valvola di sfiato Parte idraulica 15a: inserire la sfera in gomma e avvitare la boccola in plastica della valvola di sfiato. 17a: Inserire sull’estremità conica dell’albero la bussola esagonale in bronzo. Inserire sulla bussola esagonale in bronzo la girante. Serrare a fondo la vite della girante con un giravite a croce con coppia max di 3 Nm. ATTENZIONE! Sulla vite applicare qualche goccia di un prodotto “frenafiletti” di media forza. 24 www.zenit.com www.zenit.com 25 IT ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE ASSEMBLAGGIO POMPE SERIE BLUE Tav_18a Tav_19a 18a: Per pompe DRBlue:inserire la flangia di aspirazione, l’ORing e serrare le viti. ATTENZIONE! L’intaglio deve essere rivolto dalla parte opposta della bocca di mandata. IT IT 19a: Accoppiare la griglia di aspirazione orientandola in modo che uno dei piedini interni sia in corrispondenza della bocca di mandata. Nel caso di DGBlue orientare i piedi del basamento come in figura. Inserire le 3 viti e serrate a fondo con un giravite a croce con coppia max di 2 Nm. ATTENZIONE! Le viti devono essere posizionate come in figura e serrate a fondo con un giravite a croce con coppia max di 2 Nm. Per pompe DGBlue: inserire il piede di supporto e l’Oring (nella versione Professional anche la flangia inox). ATTENZIONE! Le viti devono essere posizionate come in figura e serrate a fondo con un giravite a croce con coppia max di 2 Nm. Standard Professional Tav_20a Maniglia 20a: Inserire i cavi dell’alimentazione e del galleggiante qualora presente come rappresentato in figura. 26 www.zenit.com www.zenit.com 27 ASSEMBLAGGIO POMPE BLUE/ ASSEMBLAGGIO MANUALESERIE DISASSEMBLAGGIO ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE POMPE SERIE BLUE Tav_22a Tav_21a 22a: fissare l’occhiello della connessione di terra al supporto in alluminio e eseguire le connessioni elettriche seguendo lo schema specifico della pompa. IT 21a: Inserire i cavi nei componenti nell’ordine indicato in figura. Tav_23a 23a: inserire la cartuccia dei vari componenti nella apposita sede facendo attenzione all’orientamento delle nervature di contenimento: il lato corto deve essere verso il centro della pompa. 28 www.zenit.com www.zenit.com 29 IT ASSEMBLAGGIO POMPE SERIE BLUE MANUALE DISASSEMBLAGGIO / ASSEMBLAGGIO POMPE SERIE BLUE INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_24a 24a: Calzare il gruppo manigliapressacavo fino a chiudere il vano elettrico esercitando una lieve tensione sui cavi verso l’esterno in modo da mantenere unito l’assieme durante tutta questa fase. IT EN Tav_25a INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS 25a: Inserire le viti come in figura. Avvicinare senza serrare a fondo con un giravite a croce. Serrare a fondo incrociando il serraggio delle viti 1-2-3-4 con coppia max 3Nm±30%. 30 www.zenit.com www.zenit.com 31 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INDEX Disassembling Blue90 pump Hydraulic section ...................................................................................................................... 3 Opening the oil sump ................................................................................................................ 6 Removing the mechanical seals.................................................................................................8 Removing ball bearings........................................................................................................... 10 Removing handle .................................................................................................................... 10 Removing the stator ............................................................................................................... 15 Removing Air Valve................................................................................................................. 16 Removing the stator ............................................................................................................... 17 Tav_1 Assembling Blue90 pump EN EN Preparing the driving shaft ..................................................................................................... 19 Fixed section of the mechanical seals...................................................................................... 19 Fitting the stator..................................................................................................................... 20 Fitting the driving shaft .......................................................................................................... 21 Mobile section of the mechanical seals .................................................................................... 21 Closing the oil sump................................................................................................................ 23 Filling the oil sump ................................................................................................................. 23 Closing the Air Valve ............................................................................................................... 25 Hydraulic section .................................................................................................................... 26 Handle .................................................................................................................................... 28 Hydraulic section 1: Undo the screws on the intake grating/ support foot using a crosshead screwdriver. Pag. 2 32 www.zenit.com www.zenit.com 33 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_2 Tav_4 2: Take off the intake grating/ support foot (and Oring/inox flange for DGBlue Professional). EN Standard Standard 4: Undo the screw on the impeller with a crosshead screwdriver, holding the impeller still (with a pair of pliers for example) and take off the impeller using a pair of pliers applied to the impeller hub. Professional Professional Tav_3 Tav_5 3: Undo the screws on the intake flange using a crosshead screwdriver and remove intake flange and Oring. 34 www.zenit.com 5: Tighten the rotor screw back onto the shaft using a crosshead screwdriver, making 6/8 whole turns. Not necessary for Professional version www.zenit.com 35 EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_8 Tav_6 VERTIC SX Opening the oil sump 6: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Unscrew the flange on the oil sump until it touches the bronze hexagonal socket screw, use a 30mm socket wrench. Make sure the flange is completely free. EN VERTIC 8: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Remove the screw and the bronze hexagonal socket screw. Not necessary for Professional version WARNING! Turn clockwise: the threading is left-hand! Not necessary for Professional version Tav_7 VERTIC Tav_9 7: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Tap the head of the shaft screw with a rubber hammer to release the bronze hexagonal socket screw from the tapered end of the shaft. VERTIC Not necessary for Professional version 9: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Unscrew the oil sump flange completely and lift it up, pulling it off the shaft. WARNING! Turn clockwise: the threading is left-hand. 36 www.zenit.com www.zenit.com 37 EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_10 Tav_13 VERTIC Tav_12 10: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Drain away the oil contained in the sump. 12: Pull out the shaft – lower bearing mount unit from the motor unit. 13: Undo the screw on the rotor using a crosshead screwdriver, remove the washer/ hexagonal socket screw, remove the rotating parts, the spring, the O-ring and the rubber boot (if still on the bearing) from the shaft. EN Tav_11 VERTIC Removing the mechanical seals 11: Tighten the rotor screw onto the shaft with a crosshead screwdriver, positioning a washer under the head of the screw or, if this is not possible, under the bronze hexagonal socket screw, reversing its positioning in relation to normal use. Position the two levers under the washer/socket screw in order to exert sufficient force to release the shaft unit. Tav_14 14: Tap the tapered end of the shaft with a rubber hammer, keeping the lower bearing mount resting on the bench. 15: Remove the shaft and the seal counterface from the lower bearing mount, using a screwdriver and working from the rear part. VERTIC 38 Tav_15 www.zenit.com www.zenit.com 39 EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_19 Tav_16 Removing ball bearings 16: Using an extraction tool, remove the upper bearing from the shaft. Tav_17 17: Using an extraction tool, remove the lower bearing from the shaft, taking care to protect its tapered end. EN EN Tav_18 19: Grip the handle and lift it upwards, keeping the motor unit steady. Removing handle 18: Undo the screws on the handle with a crosshead screwdriver. 40 www.zenit.com www.zenit.com 41 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_20 Tav_21 21: Undo the earth screw with a crosshead screwdriver, cut the eyelet. 20: Pulling the electric cable take off the inside components. Note down the colours of the electrical connections on a piece of paper. In any case, there are diagrams available for all the pump types. Cut the electrical connections on the connectors. EN EN Tav_22 22: Take the condenser out of the electrical compartment (if provided). 42 www.zenit.com www.zenit.com 43 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_24 Tav_23 Tav_25 Removing the stator 24: Fit the specific extraction tool supplied by Zenit inside the stator. EN EN 25: Tighten the nut with a 30mm fork wrench, turning it clockwise until the tool is fully extended. 23: Take off the components from the electric cable. 44 www.zenit.com www.zenit.com 45 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_27 Tav_26 Tav_28 Removing the stator 27: Fit the specific extraction tool supplied by Zenit inside the stator. 28: Tighten the nut with a 30mm fork wrench, turning it clockwise until the tool is fully extended. EN Tav_29 Removing Air Valve 26: with exagonal wrench undo the plastic nut and remove the rubber ball. Tav_30 Remove the cables running out of the stator, pulling them out of the condenser housing, then position them inside the punch 29: after greasing the thread of the threaded bar on the extraction tool, fit the spacer, to be used to remove the stator, into the threaded bar and tighten the M20 nut. 30: Tighten the nut clockwise with a 30mm fork wrench, until the stator has been completely removed. 46 www.zenit.com www.zenit.com 47 EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_1a Tav_31 Øi 13 mm MIN Øe 18 mm MAX Tav_2a Øi 13 mm MIN Øe 18 mm MAX Preparing the driving shaft 1a:Fit the lower bearing using a steel pipe with max. external diameter of 18mm and max. thickness of 2.5. We recommend you use a small press or a hammer. 31: Remove the stator and the tools. Clean the frame carefully then proceed with refitting. EN EN STOP STOP Tav_3a END OF DISASSEMBLING PROCEDURE 2a: Fit the upper bearing using a steel pipe with max. external diameter of 18mm and max thickness of 2.5. We recommend you use a small press or a hammer. Tav_3a_1 Fixed section of the mechanical seals 3a: Fit the in Aluminium Graphite counterface of the mechanical seal into its seat on the lower bearing mount, using the Nylon bushing provided. 3a_1: Fit the Silicon Carbide counterface of the mechanical seal into its seat on the oil sump flange, using the Nylon bushing provided for this purpose. 48 www.zenit.com www.zenit.com 49 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_6a Tav_4a 4a: Fit the pre-assembled shaft into the hole in the lower bearing mount, taking care not to touch the counterface. Gently tap the bearing into its seat with a hammer until it is flush. Fitting the driving shaft 6a: Fit the rubber boot onto the upper bearing. Fit the body of the shaft-lower bearing mount into the frame, exerting pressure with your hands. EN Tav_5a Tav_7a Fitting the stator 5a: Fit the stator into the frame using the specific tools (see drawing) until it is flush with the punch. To fit the stator, use a press with max. capacity of 8 Tons. Mobile section of the mechanical seals 7a: Fit the (aluminium graphite) rotating part of the mechanical seal onto the shaft, using the nylon punch provided until it is flush. WARNING! The stator’s cable outlet must follow the direction shown in the figure, in position with the condenser seat. 50 www.zenit.com WARNING! Check that the parts in contact with each other are clean and correctly positioned (observe the fitting direction)! www.zenit.com 51 EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_10a Tav_8a VERTIC 8a: Insert the mechanical seal spring onto the shaft fitting it onto the collar on the mechanical seal below. Closing the oil sump 10a: WARNING! Keep the pump UPRIGHT. Rest the NEW O-ring in its seat. EN EN Tav_9a Tav_11a Filling the oil sump 9a: Fit the (silicon carbide) rotating part of the mechanical seal onto the shaft, using the nylon punch provided until it is flush 11a: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Fill the sump with CASTROL PRODUCT L 320 oil until the stakes are covered, as shown in the figure. WARNING! Check that the parts in contact with each other are clean and correctly positioned (observe the fitting direction)! VERTIC 52 www.zenit.com www.zenit.com 53 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_12a Tav_14a VERTIC 14a: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Tighten the oil sump flange fully with a 30mm socket wrench to a max. tightening torque of 100 Nm. + OIL VERTIC SX 12a: WARNING! Keep the pump UPRIGHT to prevent oil leakages. With a soft-bristled brush, slightly lubricate the O-ring with CASTROL PRODUCT L 320 oil. WARNING! Turn anticlockwise: the threading is left-hand. EN EN Tav_15a Tav_13a VERTIC 13a: WARNING! Keep the pump UPRIGHT to prevent oil leakages. Join the flange-counterface assembly with the motor unit, taking care not to hit the counterflange. First screw the flange onto the oil sump with your hands, in order to engage with the thread. WARNING! Turn anticlockwise: the threading is left-hand. It is absolutely essential that the mechanical seal components are clean. 54 www.zenit.com Closing the Air Valve 15a: insert the rubber ball and the plastic nut as indicated. www.zenit.com 55 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_16a Tav_18a 16a: with exagonal wrench fully thigten the plastic nut. 18a: Fit the intake flange and the Oring and tighten the screws for DRBlue type. For DGBlue type fit the foot base and Oring (and inox flange for DGBlue Professional type). EN WARNING! The DRBlue intake flange groove must be facing the side opposite to the delivery inlet. WARNING! The screws must be positioned as shown in the figure and tightened fully with a crosshead screwdriver to a max. tightening torque of 2 Nm. Tav_17a Standard Professional Hydraulic section 17a: Fit the bronze hexagonal socket screw onto the tapered end of the shaft. Fit the rotor onto the bronze hexagonal socket screw. Fully tighten the screws on the rotor with a crosshead screwdriver to a max. tightening torque of 3 Nm. WARNING! Apply a few drops of medium-strength ‘thread-locking’ product to the screw. 56 www.zenit.com www.zenit.com 57 EN INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_19a Tav_21a 19a: Couple the intake grating, positioning it so that one of the inner feet is in position with the delivery inlet. For the DGBlue series, position the feet on the base as shown in the figure. Fit the 3 screws and tighten them fully with a crosshead screwdriver to a max. tightening torque of 2 Nm. EN EN 21a: insert the components on the electric cables in the order represented in figure. Tav_20a Handle 20a: Insert the power cables and the float cables (if the unit is equipped with a float) as shown in the figure. 58 www.zenit.com www.zenit.com 59 INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS INSTRUCTION MANUAL FOR ASSEMBLING/DISASSEMBLING BLUE SERIES PUMPS Tav_24a Tav_22a 22a: Fit an eyelet for screws with diam. 5 onto the earth cables coming from the float and the power cable. Position the eyelet on the earth underneath the screw head and tighten the screw on the aluminium support fully, using a crosshead screwdriver, to a max. tightening torque of 3,5 Nm. Connect the wires as illustrated in the diagram, or according to the positions noted down during removal. EN 24a: Fit the handle-cable clamp assembly so that it closes up the electric compartment, pulling the cables slightly outwards to keep the assembly together throughout this stage. Tav_23a Tav_25a 23a: fit the aluminium support/rubber basket/anti-stress cable and cable gland assembly, keep attention on the aluminium support orientation: the short ribs must be positioned toward the pump center. 60 25a: Insert the screws as shown in the figure. Screw them in with a crosshead screwdriver but do not tighten them fully. Tighten screws fully, working crosswise, to a max. tightening torque of 3Nm ±30%. END OF ASSEMBLING PROCEDURE www.zenit.com www.zenit.com 61 EN IT Le immagini sono puramente indicative e potrebbero non corrispondere all’aspetto reale del prodotto. I dati riportati potrebbero differire da quelli reali. Zenit si riserva la facoltà di apportare modifiche al prodotto senza alcun preavviso. Per ulteriori informazioni consultare il sito www.zenit.com. HU Az ábrák csak bemutatásra szolgálnak, a termék kinézete ettől eltérhet. Az itt felsorolt adatok eltérhetnek a valós adatoktól. A Zenit cég fenntartja a terméken előzetes bejelentés nélkül végzett módosítások jogát. További információkért látogasson el a www.zenit.com oldalra. EN The images are indicative only and may not match the actual product. Details given here may differ from the actual product. Zenit reserves the right to modify the product without prior warning. For more information, consult the website www.zenit.com. PL Ilustracje mają charakter wyłącznie orientacyjny i mogą nie odzwierciedlać rzeczywistego wyglądu produktu. Podane dane mogą odbiegać od rzeczywistych. Zenit zastrzega sobie prawo do wprowadzenie zmian bez uprzedzenia. Dodatkowe informacje znajdują się na stronie www.zenit.com. FR Les images sont fournies à titre purement indicatif et pourraient ne pas correspondre à l’aspect réel du produit.. Les données indiquées pourraient différer des éléments réels. Zenit se réserve la faculté d’apporter des modifications au produit sans aucun préavis. Pour tout renseignement complémentaire, consulter le site www.zenit.com. RO Imaginile sunt oferite exclusiv cu titlu indicativ şi este posibil să nu corespundă cu aspectul efectiv al produsului. Este posibil ca datele menţionate să fie diferite de cele reale. Zenit îşi rezervă dreptul de a aduce modificări asupra produsului fără preaviz. Pentru informaţii suplimentare, consultaţi site-ul www.zenit.com. DE Die Abbildungen dienen ausschließlich der Information und könnten vom tatsächlichen Aussehen des Produkts abweichen. Die aufgeführten Angaben könnten sich von den tatsächlichen unterscheiden. Zenit behält sich das Recht vor, ohne vorherige Benachrichtigung Änderungen am Produkt anzubringen. Weitere Informationen sind der Site www.zenit.com zu entnehmen. ET Pildid on ainult illustratiivsed ja võivad erineda tegelikest toodetest. Esitatud arvud võivad erineda tegelikest. Zenit jätab endale õiguse modifitseerida toodet ilma sellest eelnevalt teatamata. Täiendava teabe saamiseks vaadake veebilehekülge www.zenit.com. NL De afbeeldingen zijn puur ter indicatie en stemmen mogelijk niet met de werkelijkheid overeen. De vermelde gegevens kunnen anders zijn dan in werkelijkheid. Zenit behoudt zich het recht voor om het product zonder voorafgaande mededeling te wijzigen. Raadpleeg voor aanvullende informatie de website www.zenit.com. LV Attēli ir tikai orientējoši un var neatbilst faktiskajam produktam. Sniegtā informācija var atšķirties no reālās. Zenit patur tiesības mainīt produktu bez iepriekšēja brīdinājuma. Lai iegūtu sīkāku informāciju, apmeklējiet vietni www.zenit.com. ES Las imágenes tienen fines indicativos únicamente y podrían no ser iguales al producto real. Los detalles aquí dados podrían diferir del producto real. Zenit se reserva el derecho de modificar el producto sin previo aviso. Para mayor información, consulte el sitio web www.zenit.com. LT Iliustracijos yra tik pavyzdinės, todėl gali neatitikti tikrojo gaminio vaizdo. Pateikti duomenys gali skirtis nuo tikrųjų. „Zenit“ pasilieka teisę be iš ankstinio įspėjimo atlikti gaminio pakeitimus. Daugiau informacijos rasite svetainėje www.zenit.com. PT As imagens são puramente indicativas e poderão não corresponder ao aspecto real do produto. Os dados reportados poderão deferir dos reias. Zenit reserva-se a faculdade de efectuar modificações do produto sem qualquer aviso prévio. Para mais informações consultar o site www.zenit.com. CS Tyto obrázky jsou pouze ilustrační, a proto se reálná podoba produktu může lišit. Uvedená data by se od těch reálných mohla lišit. Zenit si vyhrazuje právo na změny výrobku bez povinnosti jakéhokoli předchozího upozornění. Další informace jsou k dispozici na webové adrese www.zenit.com. EL Οι εικόνες είναι καθαρά ενδεικτικές και μπορεί να μην αντιστοιχούν στο πραγματικό προϊόν. Τα αναγραφόμενα στοιχεία μπορεί να διαφέρουν από τα πραγματικά. Η Zenit διατηρεί το δικαίωμα να τροποποιεί το προϊόν χωρίς προηγούμενη ειδοποίηση. Για περισσότερες πληροφορίες, επισκεφθείτε την ιστοσελίδα www.zenit.com. SK Skutočná podoba výrobku sa môže líšiť od uvedených indikatívnych obrázkov. Uvedené údaje sa môžu líšiť od skutočných. Zenit si vyhradzuje právo modifikovať výrobok bez predbežného upozornenia. Ak potrebujete ďalšie informácie, navštívte stránku www.zenit.com. DA Billederne er kun vejledende og kan muligvis ikke svare til produktets reelle udseende. De anførte data kan være forskellige fra de virkelige. Zenit forbeholder sig ret til at foretage ændringer i produktet uden varsel. Besøg websitet www.zenit.com for at få flere oplysninger. SL Slike so samo okvirnega značaja, zato morda ne odgovarjajo dejanski podobi proizvoda. Navedeni podatki se morda razlikujejo od dejanskih. Zenit si pridržuje pravico do sprememb na proizvodu brez predhodne najave. Za naknadne podatke glej spletno stran www.zenit.com. FI Kuvat ovat vain ohjeellisia eivätkä ne välttämättä vastaa varsinaista tuotetta. Annetut tiedot saattavat poiketa todellisista. Zenit pidättää oikeuden muuttaa tuotetta ilman ennakkoilmoitusta. Lisätietoja osoitteesta www.zenit.com. HR Slike su indikativne i moguće je da ne odgovaraju u cijelosti stvarnom izgledu proizvoda. Navedeni podaci se mogu razlikovati od stvarnih. Zenit zadržava pravo izmjene proizvoda bez prethodne obavijesti. Za više informacija, posjetite www.zenit.com. SV Bilderna är endast indikativa och matchar eventuellt inte den verkliga produkten. Detaljer som ges här kan skilja sig från den verkliga produkten. Zenit reserverar sig rätten att ändra produkten utan förvarning. För mer information konsultera webbplatsen www.zenit.com. RU Изображения приводятся исключительно для иллюстрации и могут не соответствовать фактическому виду продукции. Приведенные данные могут отличаться от фактических. Компания «Zenit» оставляет за собой право вносить изменения в продукцию без предварительного уведомления. Более подробная информация содержится на сайте www.zenit.com . BG Изображенията са чисто указателни и биха могли да не отговарят на истинския вид на продукта. Посочените данни биха могли да се различават от реалните. Зенит си запазва правото да променя продукта, без да уведомява предверително за това. За допълнителна информация, посетете интернет страницата www.zenit.com. CN 图片只是用来描述,或许不与实际产品完全匹配。 给予的详细参数可能与实际产品不同。 泽尼特保留无需预先通知更改产品的权利。 请咨询网址www.zenit.com获取更多信息。 www.zenit.com Cod. 0904#1605002_0