DDE ELETTROVENTILATORI CON MOTORE ELETTRONICO DIRECT DRIVEN FANS WITH ELECTRONIC MOTOR Catalogo | Catalogue | Katalog | Catalogue | Catalogo: Q-1 05/2004 1 Nicotra Gebhardt worldwide SPAIN Ctra. Alcalá-Villar del Olmo, Km. 2,830 28810 Villalbilla-Madrid Phone +34-918846110 Fax +34-918859450 E-mail [email protected] c/.Coso, 67-75, esc. 1.a,1.oB 50001 Zaragoza Phone 00 34-976-290550 Fax 00 34-976-298127 E-mail [email protected] BELGIUM Haeghensgoed, 13 - 00/01 9270 Laarne Phone +32 (0) 9/336.00.01 Fax +32 (0) 9/336.00.05 E-mail [email protected] FRANCE 8 chemin des Mûriers BP 324 69745 Genas cedex. Phone 00 33 (0) 472790120 Fax 00 33 (0) 472790121 E-mail [email protected] SWEDEN Box 237 Kraketorpsgatan 30 43123 Mölndal Phone 00 46-31-874540 Fax 00 46-31-878590 E-mail [email protected] GREAT BRITAIN Unit D, Rail Mill Way Parkgate Business Park Rotherham South Yorkshire S62 6JQ Phone +044-01709-780760 Fax +044-01709-780762 E-mail [email protected] Monarch House 1-7 Smyth Road Bedminster Bristol Phone +44 (0)870 043 5207 Fax +44 (0)870 043 5212 E-mail [email protected] http://www.kiloheat.co.uk/ MALAYSIA Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing 43300 Seri Kembangan Selangor Phone +603-89612588 Fax +603-89618337 E-mail [email protected] Lot 1799, Bukit Belimbing Industrial Area Jalan Balakong 43300 Seri Kembangan Selangor Darul Ehsan Phone +603 8961 2588 Fax +603 8961 8337 E-mail [email protected] THAILAND 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road, Kwang Jomthong, Khet Jomthong, Bangkok 10150 Phone +662 476 1823-6 Fax +662 476 1827 E-mail [email protected] SINGAPORE No. 15 West Coast Highway # 04-08 Pasir Panjang Building Singapore 117861 Phone (065) 6265 1522 Fax (065) 6265 2400 E-mail [email protected] AUSTRALIA 47 Jesica Road, Campbellfield, VIC 3061 Phone +613-9357-7464 Fax +613-9357-8700 E-mail [email protected] INDIA Plot no 28f, Sector-31 Kasna, Greater Noida-201308 U.P. INDIA Phone +91-0120-4203400 Fax +91-0120-4203401 E-mail [email protected] CHINA 88 Tai‘An Road, XinQiao, ShiJi, Panyu Guangzhou 511450 PR CHINA Phone +86 (0)20-39960570 Fax +86 (0)20-39960569 E-mail [email protected] UNITED STATES 1503 W. Misty Breeze Cir Kaysville, UT 84037 Phone 001(801) 544-9909 Fax 001(801) 315-9400 Mobile 001(801) 694-0353 E-mail [email protected] Nicotra Gebhardt GmbH Nicotra Gebhardt S.p.A Gebhardtstrasse 19-25 74638 Waldenburg, Germany Via Modena, 18 24040 Ciserano - Loc. Zingonia (BG), Italy Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail [email protected] Phone +39 035 873 111 Fax +39 035 884 319 E-mail [email protected] www.nicotra-gebhardt.com www.nicotra-gebhardt.com DDE ELETTROVENTILATORI CON MOTORE ELETTRONICO DIRECT DRIVEN FANS WITH ELECTRONIC MOTOR Catalogo Catalogue Q-1 05/04 1.640.66 - 2000/1 - 05/04 Un modo semplice per controllare il motore in differenti applicazioni An easy way to control motor in different applications 1. GENERALI GENERAL • Motore elettronico programmabile per diverse prestazioni di funzionamento: • Programmable Electronic motor for different applications : 1. Programmazione per controllo a PORTATA costante “sensorless”. Programmazione per controllo a PRESSIONE costante “sensorless”. Programmazione per regolazione a frequenza variabile che assicura elevato rendimento anche a velocità ridotte. 1. Programming sensorless constant AIRFLOW. 2. Programming sensorless constant PRESSURE. 3. Frequency regulation gives high efficiency at low speed. • • • • • • • • • • • Working range: 100÷2000 rpm. High efficiency and low noise motor. Control with 16 KHz inverter to eliminate acoustic noise. Volt/Hertz law compliance to eliminate noise. Designed for ventilation application. Single phase supply 230 V ± 10% 50/60 Hz. Voltage supply variations are compensated. -10°÷50°C working temperature with air over motor. -20°C°÷50°C storage temperature of the fan. Motor totally closed IP 54. Insulation class F. 2. 3. • • • Range di funzionamento 100÷2000 rpm. Motore ad alta efficienza e a basso rumore. Controllo con Inverter a 16 KHz per eliminare i disturbi acustici. Legge v/f ottimizzata per il rumore. Adatto per le applicazioni di ventilazione. Alimentazione monofase 230 V ± 10% 50/60 Hz. Compensazione delle variazioni della tensione di alimentazione. -10°÷ 50°C temperatura di funzionamento con motore ventilato. -20°÷50°C temperatura di stoccaggio del ventilatore. Motore completamente chiuso in IP 54. Classe di isolamento F. • • • • • • • • 2. CONTROLLO • Controllo con segnali analogici isolati con diversi standard selezionabili (0÷10V-4÷20 mA) . Controllo con selezioni fisse mediante dip-switch. Funzione di SOFT & HARD start programmabile. Funzione di BILANCIATURA intelligente e programmabile. (vedi sezione allegata). • • • 2. CONTROL • • • • Control by analog input signals available in different selectable forms (0÷10V-4÷20 mA) . Control selectable by DIP-SWITCH. Programmable SOFT & HARD start function . BALANCING FUNCTION selectable and intelligent. (as per attached section). 3. ALLARMI e PROTEZIONI 3. PROTECTION AND ALARM • • • • • • • • • • • • 2 1. Protezione di insufficiente tensione di alimentazione Protezione di sovracorrente e di sovraccarico. Protezione termica di sicurezza hardware. Gestione della condizione di rotore bloccato. Contatto optoisolato (ALLARME) di condizioni anomale (Undervoltage, Overload, Overcurrent, Stop) Contatto optoisolato (FILTER) che indica il superamento di determinate condizioni programmabili (tipicamente filtri sporchi ) Per i contatti ALLARME e FILTER vedi la sezione specifica. • • Undervoltage protection Overcurrent and overload protection. Safety thermal hardware protection. Blocked rotor condition is controlled. Opto-insulated contact (ALARM) indicates fault conditions (Undervoltage, Overload, Overcurrent, Stop) Opto-insulated contact (FILTER ALARM) to indicate overshooting of programmable range. For ALARM and FILTER contact, see the specific section in attachment. 4. MODELS Il motore elettronico è disponibile sia in versione con controllo integrato o staccato, come da tabella n°1 in allegato. Electronic motor is available both as integrated or split version, as per attached table n°1. MOTORE – PROGRAMMABILE MOTOR - PROGRAMMABLE 4. MODELLI Esecuzione meccanica Mechanical execution Monoalbero / Single shaft Monoalbero / Single shaft Monoalbero / Single shaft Monoalbero / Single shaft Posizione Inverter Inverter Position Integrato / Built-IN Integrato / Built-IN Integrato / Built-IN Staccato / Splitted Potenza Disponibile Output Power 370 Watt 550 Watt 750 Watt 1050 Watt Tabella 1/Table 1 Bialbero / Double Shaft Bialbero / Double Shaft Bialbero / Double Shaft Bialbero / Double Shaft Staccato / Splitted Staccato / Splitted Staccato / Splitted Staccato / Splitted 370 Watt 550 Watt 750 Watt 1050 Watt 5. COLLEGAMENTI DEL MOTORE ELETTRONICO 5. ELECTRONIC MOTOR CONNECTIONS Di seguito sono riportate le connessioni di alimentazione e di controllo del motore elettronico. This page describes the electronic motor supply and control connections. Tabella 2/Table 2 ALIMENTAZIONE /MAIN SUPPLY L(Fase) 230 V+/- 10% 50/60 Hz N(Neutro) Main supply PE Ground Corrente Max sull`etichetta del ventilatore/Max current as per fan label Terra / Ground Tabella 3/ Table 3 TERMINALI DI CONTROLLO /CONTROL CONNECTION 5 Tensione ausiliaria di riferimento 5 Volt , ± 5% (V+) Auxiliary reference Voltage Imax = +1mA 6 Ingresso analogico di controllo Segnali di (IN) Analog input ingresso 7 Comune del Controllo (V-) Reference Voltage Nota 1 1 Comunicazione seriale RX via Input Note 1 (RX) PC / PC Serial connection RX Vmax = 24Vdc Imax = +5 mA 2 Comunicazione seriale TX via Open collector (TX) PC / PC Serial connection TX Vmax = 24Vdc Imax = -5 mA 4-8 Terminali contatto optoisolato Open collector (ALARM) Opto insulated terminals Vmax = 24Vdc Imax = -10 mA 3-8 Terminali contatto optoisolato Open collector (FILTER) Opto insulated terminals Vmax = 24Vdc Imax = -10 mA Nota 2 8 Comune Contatti isolati Note 2 (OPTOCOM) Reference opto insulated terminals Figura 1/ Figure 1 Nota 1 /Note 1 La comunicazione seriale via Computer necessita di un’interfaccia seriale (BOX EMC232 ) e di un programma apposito. Serial communication is possible only with serial interface (BOX EMC232) and with appropriate software Nota 2 /Note 2 ATTENZIONE !!! WARNING !!!!! Il morsetto 7 e il morsetto 8 non si possono collegare insieme. Terminals 7 and 8 must not be connected together. 3 6. PRESTAZIONI DEL MOTORE ELETTRONICO PROGRAMMABILE 6. PERFORMANCES OF PROGRAMMABLE MOTOR Il motore elettronico è predisposto per funzionare in “MODO PROGRAMMATO” per fornire diverse prestazioni a seconda degli usi. La struttura dell’algoritmo intelligente lo rende adatto ad un controllo a PORTATA e PRESSIONE costante sensorless. Tutte le programmazioni sono residenti e si mantengono anche allo spegnimento del motore stesso . Electronic motor has been designed to work in “PROGRAMMED MODE” to run in different ways for many applications. Intelligent flow-chart is used to allow sensorless constant AIRFLOW and PRESSURE control. All the programs are internally stored in the motor even in the power down condition. E’ possibile programmare: It’s possible to program: • • Different performance characteristics (called CURVES) • Input type to select a performance (called WORKING MODE) • Diverse caratteristiche di funzionamento (denominate più comunemente Curve) Il tipo di ingresso con cui selezionare una caratteristica di funzionamento (denominato Modo di Funzionamento) Controllability, by input signals, is very user friendly. La flessibilità del sistema permette di associare i segnali di controllo alle curve in modi diversi a seconda delle applicazioni. 7. CARATTERISTICHE DI FUNZIONAMENTO (CURVE) 7. PERFORMANCE CHARACTERISTICS (CURVES) Il motore è stato studiato per le seguenti caratteristiche: Motor has been designed with following characteristics: • • • • • 32 curve a portata costante o pressione costante selezionabili con segnali analogici. 16 punti di definizione per ogni curva. Approssimazione lineare tra i punti di definizione. Precisione del controllo di ogni punto (come potenza) di: • • • ± 4 watt for 370Wout models ± 7 watt for 550Wout models ± 10 watt for 750Wout models ± 10 watt for 1050Wout models ± 4 watt per i modelli da 370Wout ± 7 watt per i modelli da 550Wout ± 10 watt per i modelli da 750Wout ± 10 watt per i modelli da 1050Wout • • • Il range di utilizzo selezionato con una delle possibili combinazioni di dip-switches, viene evidenziato da un numero di giri minimo e massimo. Possibilità di riprogrammare le curve fino a 10.000 volte. Definizione di un limite di funzionamento per ogni curva che stabilisce una condizione di carico oltre alla quale segnalare un allarme (vedi sezione ALLARMI FILTRI). La Nicotra S.p.A. dispone di una gamma standard completa di ventilatori centrifughi che adottano questo tipo di tecnologia. La particolarità del prodotto lo rende adatto a tutte quelle applicazioni dove è previsto un controllo preciso della portata e della pressione senza dover più avere dei regolatori o dei sistemi di controllo con sonde ecc. per poter garantire ed identificare un punto di lavoro. La programmazione di questi ventilatori viene effettuata presso il nostro stabilimento e non può essere modificata. 4 32 constant aiflow or constant pressure curves selectable by analog input signals. Curves defined with 16 points. Linear interpolation between curve points. Precision of control point (as power) of: • • • Working range selected with one of the possible dip-switches combinations, is shown with a a minimum and a maximum speed. 10,000 cycles of reprogramming. Definition of function limit for each curve with load parameter to give an alarm when data goes out of range (see ALARM section). Nicotra S.p.A. has got a complete standard range of centrifugal fans using this type of technology. The particularity of the product suits it to all those applications where a precise control of volume and pressure is required without the need of any regulator or control system with measuring probes. These fans are factory programmed and should not be modified without approval. 8. MODO DI FUNZIONAMENTO 8. WORKING MODE Il motore elettronico è stato studiato per avere diversi modi di funzionamento con cui essere controllato. Si rende adatto agli standard più comuni di controllo analogico o a un controllo semplice mediante semplici combinazioni di dip switch, come mostrato in maniera dettagliata in allegato. In tutte le selezioni di tipo analogico è stato inserito un sistema di selezione con isteresi. L’isteresi viene calcolata automaticamente in funzione del numero di selezioni possibili e del range di valore analogico di ingresso (isteresi = metà dell’intervallo di selezione). Electronic motor has been designed to be flexibily controlled by common analog standard application or with simple combination of dip-switches, as shown below. N° 1 Modo /Mode SPEED CONTROL Questa modalità di programmazione è indicata in descrizione sul ventilatore con S. SPEED CONTROL This type of working mode is indicated on the description of the fan with S. All analog selections have built in input hysteresis. Hysteresis is automatically calculated as a function of number of selection steps. Decrizione /Description Note /Notes Il motore viene controllato solamente in velocità con diverse Dip1=ON, Dip2=Dip3=OFF tipologie di ingresso (potenziometrico 0-5V, 0-10V, 4-20mA). Schema connessioni tipico I dip-switch in questa programmazione prendono una fig.2. configurazione come da tabella 4 in allegato. Dip1=ON, Dip2=Dip3=OFF Typical connection in fig.2. Motor is speed controlled only with different input signals (potenziometric 0-5V, 0-10V, 4-20mA). Dip-switches 5 configuration in this working mode is shown in table 4. 10K 6 7 Figura 2/Figure 2 Tabella 4 / Table 4 COMMUTATORI DI SELEZIONE / DIP SWITCH Selezione Ingresso Analogico Analog Selection Input Configurazione Ingresso configuration Input type ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 Ingresso 0÷5 Volt DIP 1 = ON , DIP 2 = DIP 3 = OFF Ingresso 0÷10 Volt DIP 2 = ON , DIP 1 = DIP 3 = OFF Ingresso 4÷20 mA DIP 3 = ON , DIP 2 = DIP 3 = OFF Caratteristiche Characteristics RIN=100 K set = 0,22 sec Selezione range / numero di giri minimo & massimo Range Selection / RPM min & max Configurazione Selezione dip Range selezionato configuration switches Range selected Dip switch selection ON SWITCH 4 = ON RPMmin = 80 SWITCH 5 = ON RPM max = 880 1 2 3 4 5 6 7 SWITCH 6 = ON RIN=67 K set = 0,11 sec ON RIN=249 set = 0,22 sec ON 1 2 3 4 5 6 7 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 Selezione Verso di rotazione (vista dal lato albero) Rotation Selection ( view from shaft side ) ON 1 2 3 4 5 6 7 ON Oraria - CW DIP7 = OFF 1 2 3 4 5 6 7 1 2 3 4 5 6 7 ON ON Antioraria - CCW DIP7 = ON 1 2 3 4 5 6 7 N.B. Il verso di rotazione diventa effettivo solo all’accensione. N.B. Rotation selection is effective only at power on. SWITCH 4 = OFF SWITCH 5 = ON SWITCH 6 = ON RPMmin = 100 RPMmax = 1100 SWITCH 4 = ON SWITCH 5 = OFF SWITCH 6 = ON RPMmin = 120 RPMmax = 1320 SWITCH 4 = OFF SWITCH 5 = OFF SWITCH 6 = ON RPMmin = 140 RPMmax = 1540 SWITCH 4 = ON SWITCH 5 = ON SWITCH 6 = OFF RPMmin = 160 RPMmax = 1760 SWITCH 4 = OFF SWITCH 5 = ON SWITCH 6 = OFF RPMmin = 180 RPMmax = 1980 Balancing 1000 rpm Balancing 1500 rpm ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 5 LEGAME SEGNALE ANALOGICO - FREQUENZA RELATIONSHIP ANALOGIC SIGNAL-FREQUENCY La relazione tra la frequenza del motore e il segnale analogico di controllo è data , entro il ± 5%, da: Relationship between frequency motor and analog control signal (±5% tolerance) is given by the formula: f = ( x x0 ) f = ( x x0 ) K dipende dal campo di frequenze selezionato e dal tipo di segnale analogico di controllo (secondo tabella 5). Per frequenze inferiori a quella minima (10% fnom ) il motore viene spento. L’andamento è evidenziato in figura 3. K depends on frequency range selected and analog control signal (see table 5). When frequency is less than fmin (10% fnom) motor is off. Relationship is shown in figure 3. Figura 3/Figure 3 F [Hz] Tabella 5 / Table 5 Ingresso 0-5 V 0-5 V Input Ingresso 0-10 V 0-10 V Input Ingresso 4-20 mA 4-20 mA input X0 : X1 : : 110%fnom = (fmax) X0 X1 0V 5V 5V K 0 V 10 10 V V 4 20 16 mA mA mA 0.11• fnom [Hz/V] 0.22 •fnom [Hz/V] 99% fnom Punto di spegnimento 0.069 • fnom [Hz/mA] zero segnale controllo / zero of control signal max segnale controllo / max of control signal X1-X0 /Delta 11% fnom 10%fnom=fmin X0 10% + X0 90%+X0 9.09%+X0 2 DIP& ON/OFF Questa modalità di programmazione è indicata in descrizione sul ventilatore con D. DIP & ON/OFF This type of working mode is indicated on the description of the fan with D. 6 Si selezionano le caratteristiche mediante i dip-switch 4-5-6 (n°8 curve max) e la partenza del motore è controllata con ingresso potenziometrico ausiliario, come mostrato in figura 4. La corrispondenza tra le portate e le pressioni, con la disposizione dei dip-switch, viene decisa in fase di programmazione ed ogni ventilatore ha un documento allegato che descrive quali portate e pressioni sono state programmate. Performances are selected by dip-switches 4-5-6 (8 performance curves max) and starting phase is controlled by potentiometric input, as shown in figure 4. Assignment type by dip-switches with airflow/pressure curves are selected in programming step and each programmed fan is complete with a document indicating which airflow and pressure curve(s) have been programmed. X1 X [V]o [mA] Dip1 = ON, Dip2=Dip3 = OFF Schema avviamento motore fig. 4 Dip1=ON, Dip2=Dip3=OFF Connection for starting motor fig. 4 5 6 7 Figura 4/Figure 4 3 4 DIP & GO Questa modalità di programmazione è indicata in descrizione sul ventilatore con DG. Si selezionano le caratteristiche mediante i dip-switch Dip1 = ON, Dip2=Dip3 = OFF 4 -5-6 (n°8 curve max) e il motore parte all’accensione. Il tipo di corrispondenza tra dip-switch e portata/pressione viene decisa in programmazione ed ogni ventilatore ha un documento allegato che descrive quali portate e pressioni sono state programmate. DIP & GO This type of working mode is indicated on the description of the fan with DG. Performances are selected by dip-switches 4-5-6 (8 Dip1=ON, Dip2=Dip3=OFF performance curves max) and motor starts at power on. Assignment type by dip-switches with airflow/pressure curves are selected in programming step and each programmed fan is complete with a document indicating which airflow and pressure curve(s) have been programmed. POTENTIOMETER Questa modalità di programmazione è indicata in descrizione sul ventilatore con P. La selezione avviene con il segnale potenziometrico 0/5 Volt (+5V disponibile in uscita dal motore al morsetto V+). Il tipo di corrispondenza tra segnale potenziometrico e portata/pressione viene decisa in programmazione ed ogni ventilatore ha un documento allegato che descrive quali portate e pressioni sono state programmate. Dip1=ON, Dip2=Dip3=OFF Schema tipico fig.5 Dip1=ON, Dip2=Dip3=OFF Typical connection in fig.5 5 10K 5 POTENTIOMETER This type of working mode is indicated on the description of the fan with P. Performances are selected by potentiometric analog input signal 0/5 Volt. Assignment type by potentiometric signal with airflow/pressure curves are selected in programming step, and each programmed fan is complete with a document indicating which airflow and pressure curve(s) have been programmed. 0/10V Questa modalità di programmazione è indicata in descrizione sul ventilatore con SV. La selezione avviene con un segnale variabile da 0/10 Volt d.c. Il tipo di corrispondenza tra segnale variabile 0/10V d.c. e portata/pressione viene decisa in programmazione ed ogni ventilatore ha un documento allegato che descrive quali portate e pressioni sono state programmate. 0/10V This type of working mode is indicated on the description of the fan with SV. Performances are selected by variable input signal 0/10 Volt d.c. Assignment type by variable signal 0/10V d.c. with airflow/pressure curves are selected in programming step, and each programmed fan is complete with a document indicating which airflow and pressure curve(s) have been programmed. 6 7 Figura 5/Figure 5 Dip1=OFF, Dip2=ON, Dip3=OFF Schema tipico fig.6 Dip1=OFF, Dip2=ON, Dip3=OFF Typical connection in fig.6 5 6 V 7 Figura 6/Figure 6 7 6 4/20 mA Questa modalità di programmazione è indicata in descrizione sul ventilatore con SA. La selezione avviene con un segnale di corrente variabile da 4-20 mA. Il tipo di corrispondenza tra segnale di corrente variabile 4/20mA e portata/pressione viene decisa in programmazione ed ogni ventilatore ha un documento allegato che descrive quali portate e pressioni sono state programmate Dip1=OFF Dip2=OFF Dip3=ON Schema tipico fig.7 Dip3=ON, Dip1=Dip2=OFF Typical connection in fig.7 I 4/20 mA This type of working mode is indicated on the description of the fan with SA. 7 Performances are selected by amperometric variable input signal 4/20 mA. Assignment type amperometric variable signal 4/20mA with airflow/pressure curves are selected in programming step, and each programmed fan is complete with a document indicating which airflow and pressure curve(s) have been programmed. PARALLEL Questa modalità di programmazione è indicata in descrizione sul ventilatore con M. Per tutte le applicazioni che richiedono un controllo preciso (piu` lento) per due o più ventilatori in parallelo, è necessario prevedere l’opzione “PARALLEL”. Vedere sessione PARALLEL per informazioni dettagliate. PARALLEL This type of working mode is indicated on the description of the fan with M. Motor is designed also to realize a high precision control (slower) in order to be used in parallel fans application. Refer to “PARALLEL” section for more details. 6 7 Figura 7/Figure 7 9.0 MODALITA` “ALTA PRECISIONE” PARALLEL 9.0 “HIGH PRECISION” PARALLEL MODE Il motore elettronico è predisposto per poter realizzare un controllo preciso (e più lento) in modo da essere utilizzato in applicazione di ventilatori in parallelo. Questa opzione è realizzata (quando il motore non è programmato in velocità) con il DIP 7. Electronic motor is designed with the possibility to realize a high precision control (slower) in order to be used in parallel fans application. This option is active with DIP7 = ON (when the motor is not programmed in speed control). DIP7 = OFF DIP7= ON è Normal è Parallel/High precision In questo caso l’uscita ALARM (4/8) funziona come uscita tachimetrica per indicare la velocità a cui sta funzionando il motore. Viene fornito un segnale pwm in cui il duty-cycle è proporzionale alla frequenza di funzionamento (sincrona). F (Hz) = 0 ÷ 99 Hz è = 0-100% VM=Vdc* La tensione media fornita è quindi proporzionale alla frequenza di funzionamento. (vedi fig 8) 8 5 DIP7 = OFF DIP7= ON è Normal è Parallel/High precision In this case the ALARM output (4/8) works as tacho output where motor speed is indicated. Indication is with a pwm signal where duty cycle is proportional to motor frequency. F (Hz) = 0 ÷ 99 Hz è = 0-100% VM=Vdc* Average voltage is proportional to working frequency. (see fig. 8) Figura 8/Figure 8 4 FOUT = 315 Hz R 4 VOUT 8 R VOUT VDC VOUT Vdc Vdc 8 tON tOFF Time 9.1 FUNZIONAMENTO MASTER /SLAVE 9.1 MASTER /SLAVE OPERATION Sempre nell’opzione High precision (dip7 = on) il motore può funzionare in due modi : Always in High precision mode (dip7 = on) EMC works in two ways: MASTER SLAVE DIP4≠ OFF, DIP5≠ OFF, DIP6≠ OFF DIP4=DIP5=DIP6 = OFF (DIP1=ON) MASTER SLAVE DIP4≠ OFF, DIP5≠ OFF, DIP6≠ OFF DIP4=DIP5=DIP6 = OFF (DIP1=ON) In modalita` MASTER il motore funziona autonomamente regolando la velocità in modo da garantire le curve programmate. When MASTER mode is selected, motor works automatically regulating as per programmed curves. In modalita` SLAVE il motore funziona controllato da un segnale di tensione sull’ingresso analogico e viene comandato da un motore in funzionamento MASTER. In case of SLAVE mode, motor works controlled by analog input signal from the MASTER motor. In modalita` SLAVE la combinazione DIP (DIP4=DIP5=DIP6 = OFF) è persa nel caso di programmazione DIP&GO e DIP & ON/OFF. In SLAVE mode the combination DIP4=DIP5=DIP6 = OFF is lost in DIP&GO and DIP & ON/OFF working mode. Il collegamento tra un motore in modalita` MASTER e n motori in modalità SLAVE è mostrato in figura 9. Connection between a motor in MASTER mode and n motors in SLAVE mode is shown in figure 9. A B MASTER SLAVE 1 K Figura 9/Figure 9 9 10.0 BILANCIATURA 10.0 BALANCING Il motore elettronico prevede l’opzione di bilanciatura . La bilanciatura si realizza facilmente come in figura 10, settando opportunamente i dip-switches per ottenere le due possibili velocità di bilanciatura (vedere sessione 8.1 – Speed Control). The electronic motor has balancing option. Use figure 10 to connect the motor for balancing options, with the correct setting of dip-switches in order to obtain the correct balancing speed (see section 8.1 – Speed Control). Questa operazione viene eseguita durante la costruzione del ventilatore e non dovrà essere ripetuta se non da un operatore abilitato di Nicotra S.p.A. This operation is done during the fan manufacturing and must not be altered without a technician from Nicotra S.p.A. 5 6 7 Figura 10/Figure 10 11. ALLARMI 11. ALARMS Il motore elettronico ha disponibili come allarmi alcuni contatti optoisolati (morsetti n°3 e n°4). Il morsetto n°3 (Filter) è un allarme che si attiva quando le perdite di carico superano un certo valore (espresso come valore di pressione o di portata), stabilito in fase di programmazione. Il morsetto n°4 (Alarm) viene attivato al verificarsi di diverse condizioni anomale di funzionamento, quali Undervoltage, Wattmax, Current Limit. Electronic motor has opto-insulated contacts available for alarms (terminals n°3 and n°4). Terminal n°3 (Filter) is used to show when the selected pressure/airflow parameter is reached: this value is charged during programmation. Terminal n°4 (Alarm) is used to indicate more fault conditions (Undervoltage, Wattmax, Current Limit). L’uscita è di tipo open collector ed ha la seguente logica: ALARM ON Terminals n°3 or 4 / Terminal n°8 open ALARM OFF Terminals n°3 or 4 / Terminal n°8 closed ALLARME ON Morsetto n°3 o 4 / Morsetto n°8 Aperto ALLARME OFF Morsetto n°3 o 4 / Morsetto n°8 Chiuso Alarm output is open collector type with following logic: Durante l’accensione l’allarme rimane attivo per 5 secondi per indicare una fase di inizializzazione elettronica. During power-on phase, alarm remains on for 5 secs to indicate electronic start up. Lo schema di uscita è descritto in figura 11, mentre la tabella n°6 riassume la logica di funzionamento degli allarmi. (Il carico massimo è di 10 mA e la tensione di 24Vdc). Figure 11 describes output stage while the table n°6 shows the alarm fault indicator logic. (Max load is 10 mA and 24 Vdc). 3/4 8 Figura 11/Figure 11 10 11.1 LOGICA INDICATORI ALLARME / ALARM FAULT INDICATOR LOGIC Tabella 6 / Table 6 Uscita Output Tipo di Allarme Alarm Type Tipo di anomalia Fault type Stato motore Motor state ALLARMI ALARM Pin 4-8 Sottotensione Undervoltage Alimentazione < 150 V Supply < 150 Vac Spento Off Sovraccarico Overload ALLARME FILTRI FILTER ALARM Pin 3-8 Diminuzione autom. Frequenza Automatic decreasing frequency Spegnimennto momentaneo Instantaneous off Spento (necessità ripristino manuale) Off (with manual reset) Win > Wmax Sovraccorente Istantanea Instantaneous overcurrent Iload > Imax Stop Stop Sovraccarico persistente Persistance overload Filtri Filter Perdite di carico superiori ad un dato valore programmato Load Loss higher than the programmed value Normale, solo indicazione Normal, only indication Logica Allarmi Fault Logic Uscita tipo Open Collector Opened Collector type ALLAME ON = Contatto Aperto ALARM ON = Opened Contact ALLARME OFF = Contatto Chiuso ALARM OFF = Closed contact 11.2 ESEMPI APPLICATIVI 11.2 APPLICATION EXAMPLES I possibili utilizzi dei segnali di allarme forniti dal motore elettronico sono molteplici e danno la possibilità di essere gestiti con “impieghi semplici” quali ad esempio l’attivazione di un relè che a sua volta potrà attivare delle segnalazioni luminose. Possono essere utilizzati anche in sistemi più complessi come ad esempio dei segnali in ingresso ad un PLC. In allegato vengono schematizzate le due possibilità sopra citate (figura 12 e 13). The possible applications of the alarm signals supplied by the electronic motor are of various type and give the possibility to be managed in "simple applications" such as, for example, powering a rely that will turn on light signals. They may be used also in more complex systems such as, for example, in PLC input signals. The two above mentioned possibilities are shown in the sketches below (fig. 12 and 13). +5 ÷ +24Vdc Imax=10 mA 3/4 8 Figura 12/Figure 12 +5 ÷ +24Vdc Imax=10 mA Relè 3/4 PLC 8 Figura 13/Figure 13 11 COLLEGAMENTO CON RELE’ - Figura 12 RELE’ APPLICATION - Figure 12 1 -- ALLARME ON Relè Aperto Quando l’allarme è ON il circuito è aperto e il Relè non è eccitato. 1 -- ALARM ON Rely Powerless When Alarm is ON the circuit is opened and the Rely is powerless. 2 -- ALLARME OFF Relè Chiuso Quando l’allarme è OFF il circuito è chiuso e il Relè è eccitato. 2 -- ALARM OFF Rely Powered When Alarm is OFF the circuit is closed and the Rely is powered. COLLEGAMENTO AD UN PLC - Figura 13 PLC CONNECTION - Figure 13 ALLARME ON ALLARME OFF ALARM ON ALARE OFF Ingresso PLC - HIGH (*) Ingresso PLC - LOW (*) PLC Input - HIGH (*) PLC Input – LOW (*) (*) HIGH /LOW : voltage of input signal is related to the auxiliary supply (24Vdc – 5Vdc – ecc.) (*) HIGH /LOW : la tensione del segnale in ingresso al PLC dipende dalla tensione ausiliaria di riferimento (24Vdc – 5Vdc – ecc.) Gli allarmi, possono essere usati per poter monitorare più ventilatori collegati tra loro ed intervenire per risolvere problematiche legate al verificarsi di una condizione anomala (intervento del morsetto Alarm) o al raggiungimento del valore programmato di filtro (intervento del morsetto Filter). A questo scopo è possibile effettuare una connessione degli allarmi in serie, che evidenzierà una condizione di allarme anche se un solo motore è in condizione di allarme. La figura 14 ci mostra appunto come collegare tra loro i segnali di allarme di due o più motori in serie. The alarms may be used to control more fans in connection and to intervene and solve problems related to the occurrance of anomalous conditions (intervention of the Alarm terminal) or when the programmed filter value is achieved (intervention of the Filter terminal). With this aim, it is possible to connect the alarms in series, so that the alarm condition will be signalled even if only one motor is in alarm condition. Fig. 14 shows how to connect the alarm signals of two or more motors in series. 5/24V 5 k OPTOCOM ALARM OUT Figura 14/Figure 14 12 L’esempio presentato schematizza come connettere in serie gli allarmi di sovraccarico : è chiaro che la stessa operazione può essere effettuata anche per collegare in serie i morsetti n°3 per la visualizzazione dell’allarme Filter. The example presented above shows how to connect the overload alarms in series: it is clear that the same operation can be made also to connect the n°3 terminals in series, in order to display the Filter alarm. Un ulteriore utilizzo degli allarmi, è quello di poter essere collegati in parallelo e di essere inviati come segnali digitali per un dispositivo PLC : collegando opportunamente come mostrato in figura 15, abbiamo in questo caso la possibilità di identificare quale degli n° ventilatori collegati in parallelo è in una condizione di allarme. Rispetto alla connessione allarmi in serie che offre la condizione di allarme quando uno degli n° ventilatori è in allarme, la connessione in parallelo ci permette di identificare con precisione su quale ventilatore poter effettuare dei controlli, o effettuare la manutenzione, per esempio per pulizia dei filtri. One further application of the alarms is to be connected in parallel and to be sent as digital signals for a PLC device: with a proper connection, as shown in Fig. 15, there is the possibility to identify which of the n° fans connected in parallel is in alarm condition. In comparison to the alarm connection in series, displaying the alarm condition when one of the n° fans is in alarm, the connection in parallel allows to identify precisely on which fan a control is required or to make a maintenance, for example, to clean the filters. +5 ÷ +24Vdc Imax=10 mA DDE 1 3/4 Input 1 8 +5 ÷ +24Vdc Imax=10 mA DDE 2 3/4 Input 2 8 +5 ÷ +24Vdc Imax=10 mA DDE n 3/4 Input n 8 PLC digital Input Figura 15/Figure 15 Collegamenti non conformi alle specifiche e alle indicazioni fornite da Nicotra S.p.A. possono danneggiare l’inverter del motore in maniera irreversibile tale da rendere inutilizzabile il ventilatore se non ripristinando un nuovo motore o inverter. L’accertamento di danneggiamento dovuto ad operazioni non conformi, può portare al non riconoscimento della garanzia sul componente o sull’intero ventilatore. Connections not in conformity with the specifications and with the indications supplied by Nicotra S.p.A. may damage irreversibly the motor inverter, in such a way that the fan cannot be used any longer if the motor or the inverter are not replaced with new ones. If the damage is proved to be caused by operations not in conformity to what above mentioned, the warranty may not cover the replacement of the component or of the whole fan. 13 GAMMA E CODICI RANGE AND PART NUMBERS VENTILATORI A VELOCITA' VARIABILE VARIABLE SPEED FANS MOT. 370 W 0-10V MOT. 550 W 0-10V 9/7 TIGHT 610509 9/9 TIGHT 610510 610534 9/7 610500 610501 9/9 610502 610505 MOT. 750 W 0-10V MOT. 1050 W 0-10V VENTILATORI A PORTATA COSTANTE CONSTANT AIRFLOW FANS MOT. 370 W 8QK MOT. 550 W 8QK MOT. 750 W 8QK MOT. 1050 W 8QK VENTILATORI A PRESSIONE COSTANTE CONSTANT PRESSURE FANS MOT. 550 W 8PK MOT. 750 W 8PK 610553 610557 610520 610525 610519 10/8 610506 610511 10/10 610507 610512 610556 610542 610549 610527 12/9 610513 610545 610550 12/12 610514 610544 610551 610546 610552 VENTILATORI BINATI TWIN FANS DD2E 185/240 M9K2 Mot. 370W 0-10V cod. 610554 DD2E 7/7 M9K3 Mot. 750W 8QK cod. 610555 14 NOTA : NOTE : I ventilatori binati sono realizzabili su richiesta anche in modalità con pressione costante e regolazione di velocità. Twin fans may be manufactured on request also with constant pressure mode and speed control. VENTILATORI A VELOCITÁ VARIABILE VARIABLE SPEED FANS QUOTE DIMENSIONALI - DIMENSIONS Taglia Size 9/7 TIGHT 9/9 TIGHT 9/7 9/9 Motore Motor 370 W 550 W 370 W 550 W 370 W 550 W 370 W 550 W 10/8 tutti i motori - all motors 10/10 tutti i motori - all motors 12/9 tutti i motori - all motors 12/9 1050 W 12/12 tutti i motori - all motors 12/12 1050 W A B C E F G H L P mm mm mm mm mm mm mm mm mm 326 326 326 326 387 387 387 387 443 443 521 521 521 521 185 185 185 185 215 215 215 215 249 249 294 294 294 294 262 262 262 262 262 262 262 262 289 289 341 341 341 341 167 167 167 167 160 160 160 160 178 178 213 213 213 213 318 318 318 318 380 380 380 380 425 425 491 491 491 491 155 155 155 155 185 185 185 185 203 203 230 230 230 230 232 232 298 298 232 232 298 298 265 331 309 309 395 395 349 364 393 396 349 364 393 396 378 421 401 400 487 486 117 132 95 98 117 132 95 98 113 90 92 91 92 91 ORIENTAMENTO SCATOLA MOTORE - MOTOR BOX ORIENTATION 16 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 650 COD. 610509 1 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 600 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 550 72.1 500 2 69.3 dB(A) 450 69 DDE 9/7 Tight 1419H6 2684.* 27/12/01 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 4.2 IP 54 YES-IN F 67.9 400 Static pressure [Pa] Type: Motor: Test nr.: Date: 70.3 3 66.5 350 67.2 300 69.5 4 63 250 71.5 63.6 68.9 5 200 57.6 59.5 150 64.3 100 72.1 50 72.3 0 0 500 1000 1500 2000 2500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 650 COD. 610510 1 - Fan Max Working Limit 1 600 2 - 90Hz - Constant Vdc Signal = 8.1V 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 550 5 - 90Hz - Constant Vdc Signal = 5.1V 70.4 500 2 450 70.2 dB(A) 67.8 Static pressure [Pa] 400 Type: Motor: Test nr.: Date: DDE 9/9 Tight 1419H6 2661.* 15/10/01 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 4.3 IP 54 YES-IN F 67.9 3 350 65.3 66.2 300 67.2 4 61.3 69.4 250 63.9 5 200 57.2 70.3 58.9 150 68.1 100 63.7 50 69.3 73.2 0 0 500 1000 1500 Flow rate [m3/h] 2000 2500 3000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. 17 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 700 COD. 610534 1 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 650 3 - 90Hz - Constant Vdc Signal = 7.1V 72.3 4 - 90Hz - Constant Vdc Signal = 6.1V 600 5 - 90Hz - Constant Vdc Signal = 5.1V 550 72.2 dB(A) 2 500 70.7 450 Static pressure [Pa] Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 400 3 69.1 65.4 350 66.5 70 4 300 62.4 67.8 250 71.2 63 5 65.1 200 71.2 Type: Motor: Test nr.: Date: DDE 9/9 Tight 1419H7 2772.* 17/07/02 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.3 IP 54 YES-IN F 57 58.6 150 73.9 63.7 100 72.5 50 74.7 69.2 0 0 500 1000 1500 2000 2500 3000 3500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 650 1 COD. 610500 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 600 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 550 69.1 500 2 450 66.7 68.1 67 Type: Motor: Test nr.: Date: DDE 9/7 1419H6 2654.* 06/10/01 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 4.3 IP 54 YES-IN F 69.1 dB(A) Static pressure [Pa] 400 65.8 3 350 64.1 69 300 62.6 4 63.8 70.8 250 68.8 200 5 58.4 56.4 61.7 150 71.9 100 67.4 72.1 50 0 0 500 1000 1500 Flow rate [m3/h] 18 2000 2500 3000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 700 COD. 610501 1 - Fan Max Working Limit 1 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 2 - 90Hz - Constant Vdc Signal = 8.1V 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 600 70.8 71.8 dB(A) 500 68.3 2 Static pressure [Pa] 400 66.2 3 68.4 64.6 73.2 73 300 62.8 4 64.8 60.8 69.4 59.9 5 DDE 9/7 1419H7 2655.* 06/10/01 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.7 IP 54 YES-IN F 69.8 67.2 200 Type: Motor: Test nr.: Date: 56.6 65.3 100 73.5 75.7 69.4 75.6 0 0 500 1000 1500 2000 2500 3000 3500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 600 COD. 610502 1 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 550 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 500 70.1 2 450 Static pressure [Pa] 400 68.3 68.5 3 67 65.5 300 4 68.7 64.3 62.4 69.7 200 5 67.9 60.1 58.9 DDE 9/9 1419H6 2702.* 24/02/02 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 4.4 IP 54 YES-IN F 68.4 dB(A) 67.6 350 250 Type: Motor: Test nr.: Date: 57.9 71.1 150 64.1 100 71.7 50 71 0 0 500 1000 1500 2000 Flow rate [m3/h] 2500 3000 3500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. 19 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 700 COD. 610505 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 1 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 600 73.3 500 2 72.1 dB(A) Type: Motor: Test nr.: Date: DDE 9/9 1419H7 2713.* 24/02/02 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.8 IP 54 YES-IN F Static pressure [Pa] 71 70.3 69.8 400 68.7 3 71.2 68.1 66.1 300 72.1 4 71 63.8 63.3 66.8 5 200 73.6 60.8 58.2 71.7 64.1 75 100 70.2 0 0 500 1000 1500 2000 2500 3000 72.5 75.5 3500 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 900 COD. 610506 1 - Fan Max Working Limit 1 2 - 90Hz - Constant Vdc Signal = 8.1V 3 - 90Hz - Constant Vdc Signal = 7.1V 800 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 700 72.8 2 71.8 600 Static pressure [Pa] 70.4 500 3 70.7 67.8 68.5 69.5 400 70.8 4 66.8 68.9 65.3 70.3 71.4 300 5 60.4 61.6 DDE 10/8 1419H7 2695.* 19/01/02 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.5 IP 54 YES-IN F 71.2 dB(A) 70 67.9 Type: Motor: Test nr.: Date: 63 65.1 200 67 73.4 71.3 100 73.4 71.1 70.3 0 0 1000 2000 Flow rate [m3/h] 20 3000 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 900 COD. 610511 1 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 3 - 90Hz - Constant Vdc Signal = 7.1V 800 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 73.4 700 72.5 2 600 72 dB(A) Static pressure [Pa] Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 7.2 IP 54 YES-IN F 71.2 71.8 3 69.3 68.4 70.1 68 72.8 72 400 4 66.5 67.3 69.4 66.2 73.6 72 300 5 DDE 10/8 1419H8 2694.* 19/01/02 71 70.6 500 Type: Motor: Test nr.: Date: 62.1 60.6 65 74.3 67.7 200 69.7 73.8 100 72.2 73.3 0 0 1000 2000 3000 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 900 1 COD. 610507 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 800 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 5 - 90Hz - Constant Vdc Signal = 5.1V 700 73.1 2 600 71.8 Type: Motor: Test nr.: Date: DDE 10/10 1419H7 2650.* 29/09/01 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.8 IP 54 YES-IN F Static pressure [Pa] 71.1 70.9 70.6 3 500 69.7 70.1 67.4 66.7 66.6 400 68.4 dB(A) 66.7 4 63.9 65.2 63.2 68.3 300 67 5 59.7 61.4 59.4 200 72.3 63.4 65.9 69.6 100 65.7 0 0 1000 2000 Flow rate [m3/h] 3000 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. 21 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1000 COD. 610512 1 900 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 800 5 - 90Hz - Constant Vdc Signal = 5.1V 74.9 700 72.4 2 DDE 10/10 1419H8 2649.* 29/09/01 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 7.6 IP 54 YES-IN F 73 600 Static pressure [Pa] Type: Motor: Test nr.: Date: 72.3 dB(A) 3 71.8 71.4 71.6 500 68.2 69.9 68.4 69.8 4 400 69.4 69.9 66.3 65.4 5 300 68.5 71.1 60.9 61.8 60.3 64.3 200 66.3 70.5 100 66.9 0 0 1000 2000 3000 4000 5000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 1100 COD. 610513 1 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 1000 3 - 90Hz - Constant Vdc Signal = 7.1V 4 - 90Hz - Constant Vdc Signal = 6.1V 75.9 2 5 - 90Hz - Constant Vdc Signal = 5.1V 900 74.3 73.9 800 73.5 3 72.9 dB(A) Static pressure [Pa] 700 Type: Motor: Test nr.: Date: DDE 12/9 1419H8 2799.* 12/11/02 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 7.4 IP 54 YES-IN F 71.9 71.4 72.8 70.4 4 600 71 70.7 69.4 71 68.2 500 67.8 68.2 69.2 70.7 5 400 64 63.4 64.2 300 65 68.5 65.9 68 200 64 100 59.4 0 0 1000 2000 Flow rate [m3/h] 22 3000 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1200 COD. 610545 1 - Fan Max Working Limit 1 2 - 60Hz - Constant Vdc Signal = 7.5V 3 - 60Hz - Constant Vdc Signal = 6.8V 1100 4 - 60Hz - Constant Vdc Signal = 6V 5 - 60Hz - Constant Vdc Signal = 5.3V 79 1000 77.8 900 2 75.6 dB(A) 75.8 800 Type: Motor: Test nr.: Date: DDE 12/9 1419H9 2938.* 21/04/04 Watt: Volt: Hz: Poles: mF: 1050 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 8.2 IP 54 YES-IN F 75.4 74.1 Static pressure [Pa] 3 74 700 73.6 73.4 72.5 72.7 600 71.7 4 72.4 70.9 500 71.1 69.8 72.2 5 67.7 400 67.1 66.4 68.7 69.7 66.8 71.3 300 71.2 200 71.2 100 71 0 0 1000 2000 3000 4000 5000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. Flow rate [m3/h] 1100 COD. 610514 1 1000 1 - Fan Max Working Limit 2 - 90Hz - Constant Vdc Signal = 8.1V 3 - 90Hz - Constant Vdc Signal = 7.1V 900 4 - 90Hz - Constant Vdc Signal = 6.1V 73 5 - 90Hz - Constant Vdc Signal = 5.1V 800 2 72.1 71.2 Static pressure [Pa] 700 600 69.6 69.1 67.6 500 67.4 66.5 67.6 66.7 4 66.8 400 65.8 62.5 5 300 DDE 12/12 1419H8 2634.* 13/12/01 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 7.6 IP 54 YES-IN F 70.3 dB(A) 71 3 Type: Motor: Test nr.: Date: 62.1 62.2 62.6 57 200 56.7 57.4 62.7 58.6 61 100 0 0 500 1000 1500 2000 2500 Flow rate [m3/h] 3000 3500 4000 4500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. 23 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1300 COD. 610544 1 1200 1 - Fan Max Working Limit 2 - 60Hz - Constant Vdc Signal = 6.8V 3 - 60Hz - Constant Vdc Signal = 6.0V 1100 4 - 60Hz - Constant Vdc Signal = 5.3V 5 - 60Hz - Constant Vdc Signal = 4.5V 77.3 1000 900 2 DDE 12/12 1419H9 S2355.* 16/06/03 Watt: Volt: Hz: Poles: mF: 1050 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 8.4 IP 54 YES-IN F 76 800 Static pressure [Pa] Type: Motor: Test nr.: Date: 73.5 74.6 dB(A) 700 3 72.4 600 71.1 71.7 69.9 4 69.6 70 500 67.8 68.7 67.7 66.9 400 5 66 64.4 65.5 67.8 64.6 63.2 300 63 63.7 61.5 65.7 67 200 100 65.7 0 0 1000 2000 3000 Flow rate [m3/h] 24 4000 5000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. VENTILATORI A PORTATA COSTANTE CONSTANT AIRFLOW FANS QUOTE DIMENSIONALI - DIMENSIONS Taglia Size 9/7 TIGHT 9/9 TIGHT 9/7 9/9 Motore Motor 370 W 550 W 370 W 550 W 370 W 550 W 370 W 550 W 10/8 tutti i motori - all motors 10/10 tutti i motori - all motors 12/9 tutti i motori - all motors 12/9 1050 W 12/12 tutti i motori - all motors 12/12 1050 W A B C E F G H L P mm mm mm mm mm mm mm mm mm 326 326 326 326 387 387 387 387 443 443 521 521 521 521 185 185 185 185 215 215 215 215 249 249 294 294 294 294 262 262 262 262 262 262 262 262 289 289 341 341 341 341 167 167 167 167 160 160 160 160 178 178 213 213 213 213 318 318 318 318 380 380 380 380 425 425 491 491 491 491 155 155 155 155 185 185 185 185 203 203 230 230 230 230 232 232 298 298 232 232 298 298 265 331 309 309 395 395 349 364 393 396 349 364 393 396 378 421 401 400 487 486 117 132 95 98 117 132 95 98 113 90 92 91 92 91 ORIENTAMENTO SCATOLA MOTORE - MOTOR BOX ORIENTATION 26 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 700 COD. 610520 Constant flow rate curves : 1 - 650 m3/h 650 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 2 - 800 m3/h 600 3 - 1000 m3/h 4 - 1200 m3/h 5 - 1400 m3/h 72.9 550 6 - 1600 m3/h 7 - 1800 m3/h 8 - 2000 m3/h 500 68.8 Static pressure [Pa] 70 70.8 450 Type: Motor: Test nr.: Date: DDE 9/7 Tight 1419H6 2685.* 28/12/01 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 4.2 IP 54 YES-IN F 68.5 68.7 400 350 66.5 66.4 71.1 dB(A) 66.2 65.2 300 65.9 64.6 62.9 63 250 70.7 67.2 69 63.5 62.3 64.5 68.5 66.1 200 59.8 60.1 60.1 64.5 61 57.3 67.9 72.1 62.8 57.4 71.6 59.8 52.8 100 69.8 64.7 57.1 150 70 69.1 66.7 52.3 47.2 50 1 2 70.5 55 49.6 3 60 62.3 4 6 5 67.1 64.2 68.8 7 8 0 0 500 1000 1500 2000 Flow rate [m3/h] 2500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 9/7 Tight M9H6 1F 8QK SV LEGENDA : • SEGNALE / PORTATA COSTANTE : Corrispondenza tra il segnale ed il valore della portata costante. INPUT SIGNAL CONSTANT AIRFLOW FILTER ALARM 1 0.00 – 1.25 650 m3/h 63.20 mm Hst 2 1.25 – 2.51 800 m3/h 58.25 mm Hst 3 2.51 – 3.76 1000 m3/h 55.33 mm Hst 4 3.76 – 5.02 1200 m3/h 47.86 mm Hst LEGEND : 5 5.02 – 6.27 1400 m3/h 42.92 mm Hst 6 6.27 – 7.53 1600 m3/h 40.00 mm Hst • INPUT SIGNAL / CONSTANT AIRFLOW : Correspondence between input signal and the value of the constant airflow. 7 7.53 – 8.78 1800 m3/h 34.00 mm Hst 8 8.78 – 10.04 2000 m3/h 30.00 mm Hst • SEGNALE / ALLARME FILTRO : Corrispondenza tra il segnale e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • INPUT SIGNAL / FILTER ALARM : Correspondence between input signal and the max static pressure reachable without alarm filter operating. 27 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Constant flow rate curves : 1 - 700 m3/h 800 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m COD. 610525 2 - 900 m3/h 750 3 - 1100 m3/h 4 - 1400 m3/h 5 - 1600 m3/h 700 6 - 1800 m3/h 7 - 2000 m3/h 650 8 - 2200 m3/h 70.3 600 70.6 dB(A) 68 68.9 550 67.8 68.9 Static pressure [Pa] 69 500 67.5 450 66.1 68.1 400 68.6 67.6 69.2 66.3 64.8 65.6 63.1 68 66.6 65.3 350 61.8 66.7 67.8 64.8 61 61.3 250 58.5 62.4 65.8 58.6 57.1 200 69.5 63.5 61.3 300 DDE 9/7 1419H7 2722.* 12/03/02 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6 IP 54 YES-IN F 70.2 67 66.1 Type: Motor: Test nr.: Date: 67.1 61.9 150 52.8 55.5 53.9 100 66.1 63.7 59.2 66.7 61.4 48.8 53.7 1 50 3 2 0 0 500 1000 63.2 64.8 57.6 60.4 4 5 1500 Flow rate [m3/h] 6 7 2000 66.3 8 2500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 9/7 M9H7 1F 8QK SV LEGENDA : 28 • SEGNALE / PORTATA COSTANTE : Corrispondenza tra il segnale ed il valore della portata costante. INPUT SIGNAL CONSTANT AIRFLOW FILTER ALARM 1 0.00 – 1.25 700 m3/h 65.75 mm Hst 2 1.25 – 2.51 800 m3/h 64.00 mm Hst 3 2.51 – 3.76 1100 m3/h 62.50 mm Hst 4 3.76 – 5.02 1400 m3/h 61.80 mm Hst LEGEND : 5 5.02 – 6.27 1600 m3/h 61.75 mm Hst 6 6.27 – 7.53 1800 m3/h 60.20 mm Hst • INPUT SIGNAL / CONSTANT AIRFLOW : Correspondence between input signal and the value of the constant airflow. 7 7.53 – 8.78 2000 m3/h 55.00 mm Hst 8 8.78 – 10.04 2200 m3/h 49.90 mm Hst • SEGNALE / ALLARME FILTRO : Corrispondenza tra il segnale e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • INPUT SIGNAL / FILTER ALARM : Correspondence between input signal and the max static pressure reachable without alarm filter operating. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 700 COD. 610519 Constant flow rate curves : 1 - 800 m3/h 650 2 - 1000 m3/h 600 3 - 1200 m3/h 4 - 1400 m3/h 5 - 1600 m3/h 74.1 550 6 - 1800 m3/h 7 - 2000 m3/h 8 - 2200 m3/h 500 Type: Motor: Test nr.: Date: DDE 9/9 1419H6 2672.* 23/11/01 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 3.5 IP 54 YES-IN F Static pressure [Pa] 450 70.5 400 68.2 67.9 67.5 67.9 dB(A) 350 65.7 300 67.9 64.9 64.7 64.7 65.2 64.3 250 61.2 61.3 62.2 62 61.6 200 59.1 150 59 59.4 64.6 62.7 63.6 59.5 61.4 55.8 55.4 64.8 57.1 59 52.3 48.6 60.3 62.4 64.1 2 50 1 0 500 60.4 57.3 48.1 3 0 66.1 59.3 56.7 100 66.8 4 1000 53.5 1500 Flow rate [m3/h] 5 6 62.5 7 2000 64 8 2500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 9/9 M9H6 1F 8QK D DIP-SWITCH CONSTANT POSITION AIRFLOW FILTER ALARM ON 1 2 3 4 5 6 7 800 m3/h 54.07 mm Hst 1000 m3/h 49.92 mm Hst 1200 m3/h 44.90 mm Hst 1400 m3/h 40.84 mm Hst 1600 m3/h 38.14 mm Hst 1800 m3/h 34.10 mm Hst 2000 m3/h 32.16 mm Hst 2200 m3/h 29.98 mm Hst LEGENDA : • POSIZIONE DIP-SWITCH / PORTATA COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della portata costante. ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 LEGEND : ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • DIP-SWITCH POSITION / CONSTANT AIRFLOW : Correspondence between dip-switches position and the value of the constant airflow. ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max static pressure reachable without alarm filter operating. 29 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 750 2 - 1400 m3/h 650 3 - 1600 m3/h 4 - 1800 m3/h 72.7 5 - 2000 m3/h 600 6 - 2300 m3/h 7 - 2600 m3/h 71.3 550 8 - 2900 m3/h 70.8 500 Static pressure [Pa] COD. 610556 Constant flow rate curves : 1 - 1200 m3/h 700 68.4 400 68.3 70.5 67.5 350 66.6 65 66.2 67.8 69.1 66.3 300 250 63.8 66.2 72 dB(A) 69 71.1 63.5 200 59.9 65.9 63.5 150 DDE 9/9 1419H7 2670.* 09/11/01 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 5.8 IP 54 YES-IN F 70.3 70.4 69.5 69.2 450 Type: Motor: Test nr.: Date: 68 70.3 56.3 59.4 100 65.4 61.8 67.7 69.6 58.1 50 1 3 61.8 60 2 0 4 0 500 1000 1500 64.4 5 Flow rate [m3/h] 69.7 8 7 6 2000 66.9 2500 3000 3500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 9/9 M9H7 1F 8QK SV LEGENDA : 30 • SEGNALE / PORTATA COSTANTE : Corrispondenza tra il segnale ed il valore della portata costante. INPUT SIGNAL CONSTANT AIRFLOW FILTER ALARM 1 0.00 – 1.25 1200 m3/h 60.00 mm Hst 2 1.25 – 2.51 1400 m3/h 56.30 mm Hst 3 2.51 – 3.76 1600 m3/h 51.89 mm Hst 4 3.76 – 5.02 1800 m3/h 48.00 mm Hst LEGEND : 5 5.02 – 6.27 2000 m3/h 44.95 mm Hst 6 6.27 – 7.53 2300 m3/h 42.98 mm Hst • INPUT SIGNAL / CONSTANT AIRFLOW : Correspondence between input signal and the value of the constant airflow. 7 7.53 – 8.78 2600 m3/h 38.00 mm Hst 8 8.78 – 10.04 2900 m3/h 25.89 mm Hst • SEGNALE / ALLARME FILTRO : Corrispondenza tra il segnale e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • INPUT SIGNAL / FILTER ALARM : Correspondence between input signal and the max static pressure reachable without alarm filter operating. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 900 850 COD. 610542 Constant flow rate curves : 1 - 1700 m3/h 800 2 - 2000 m3/h 3 - 2300 m3/h 750 4 - 2600 m3/h 5 - 2900 m3/h 72.1 700 6 - 3100 m3/h 72.4 7 - 3300 m3/h 72.4 8 - 3500 m3/h 650 Static pressure [Pa] 600 71.6 70.1 Type: Motor: Test nr.: Date: DDE 10/8 1419H8 2530.* 12/12/00 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.9 IP 54 YES-IN F 70.5 550 71.8 500 68.1 72.1 450 68.6 70.4 71 400 67.1 73 dB(A) 350 67.3 71.7 73.1 69.3 300 67.4 65.1 62.3 72.3 250 62.4 200 57.8 150 66.3 68.7 70.2 68.3 100 71.4 67.6 59.1 54.3 50 2 1 64.2 62 4 3 0 0 500 1000 1500 71.1 62.8 2000 2500 Flow rate [m3/h] 67.9 5 6 3000 71.6 70.3 7 3500 8 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 10/8 M9H8 1F 6p 8QK D DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 1700 m3/h 65.06 mm Hst 2000 m3/h 62.08 mm Hst 2300 m3/h 60.02 mm Hst 2600 m3/h 55.19 mm Hst 2900 m3/h 45.34 mm Hst 3100 m3/h 40.20 mm Hst 3300 m3/h 34.98 mm Hst 3500 m3/h 30.58 mm Hst ON 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PORTATA COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della portata costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • DIP-SWITCH POSITION / CONSTANT AIRFLOW : Correspondence between dip-switches position and the value of the constant airflow. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max static pressure reachable without alarm filter operating. 31 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 800 COD. 610549 1 750 Constant flow rate curves : 1 - 1600 m3/h 2 700 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 2 - 1800 m3/h 3 3 - 2100 m3/h 4 - 2400 m3/h 650 5 - 2700 m3/h 4 6 - 3000 m3/h 72.1 600 7 - 3300 m3/h 8 - 3600 m3/h 5 550 70.5 6 Static pressure [Pa] 500 Type: Motor: Test nr.: Date: DDE 10/10 1419H7 2679.* 06/12/01 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6 IP 54 YES-IN F 70.9 69.6 7 450 70.6 400 66.9 8 65.5 350 66.8 65.5 68.8 64.1 68.2 dB(A) 300 64.3 62.3 62.4 64.3 250 65.7 67.7 70.8 60.6 200 58.4 150 61.7 62.9 66.9 59.8 62.3 100 56 68.5 63.3 66.5 49.5 51.1 54.4 50 58.1 60.2 62 0 0 500 1000 1500 2000 67.7 66 59.7 56.1 56.4 2500 Flow rate [m3/h] 3000 64.4 3500 68.1 66.9 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 10/10 M9H7 1F 8QK SV LEGENDA : 32 • SEGNALE / PORTATA COSTANTE : Corrispondenza tra il segnale ed il valore della portata costante. INPUT SIGNAL CONSTANT AIRFLOW FILTER ALARM 1 0.00 – 1.25 1600 m3/h 58.00 mm Hst 2 1.25 – 2.51 1800 m3/h 53.87 mm Hst 3 2.51 – 3.76 2100 m3/h 47.75 mm Hst 4 3.76 – 5.02 2400 m3/h 42.00 mm Hst LEGEND : 5 5.02 – 6.27 2700 m3/h 40.00 mm Hst 6 6.27 – 7.53 3000 m3/h 38.00 mm Hst • INPUT SIGNAL / CONSTANT AIRFLOW : Correspondence between input signal and the value of the constant airflow. 7 7.53 – 8.78 3300 m3/h 29.67 mm Hst 8 8.78 – 10.04 3600 m3/h 24.00 mm Hst • SEGNALE / ALLARME FILTRO : Corrispondenza tra il segnale e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • INPUT SIGNAL / FILTER ALARM : Correspondence between input signal and the max static pressure reachable without alarm filter operating. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1000 950 COD. 610527 1 Constant flow rate curves : 1 - 2000 m3/h 900 2 850 2 - 2300 m3/h 3 - 2600 m3/h 3 800 4 - 2900 m3/h 5 - 3200 m3/h 750 6 - 3500 m3/h 4 7 - 3800 m3/h 700 8 - 4000 m3/h 5 Static pressure [Pa] 650 600 6 550 7 500 69.7 8 450 68.5 dB(A) 400 69.1 66.7 350 64.1 300 64.8 62.1 250 66.7 68.1 61.9 69.6 Type: Motor: Test nr.: Date: DDE 10/10 1419H8 2786.* 08/10/02 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.9 IP 54 YES-IN F 70.7 68.7 200 59.2 59.4 63.5 65.4 150 70 100 54.8 56.9 50 56.9 65 66.4 62.4 68.9 0 0 1000 2000 3000 Flow rate [m3/h] 4000 5000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 10/10 M9H8 1F 6p 8QK D DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 2000 m3/h 63.17 mm Hst 2300 m3/h 56.00 mm Hst 2600 m3/h 52.50 mm Hst 2900 m3/h 49.67 mm Hst 3200 m3/h 47.50 mm Hst 3500 m3/h 35.62 mm Hst 3800 m3/h 30.00 mm Hst 4000 m3/h 26.42 mm Hst ON 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PORTATA COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della portata costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • DIP-SWITCH POSITION / CONSTANT AIRFLOW : Correspondence between dip-switches position and the value of the constant airflow. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max static pressure reachable without alarm filter operating. 33 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 1000 950 COD. 610550 Constant flow rate curves : 1 - 1600 m3/h 900 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 2 - 1800 m3/h 850 3 - 2000 m3/h 4 - 2200 m3/h 800 5 - 2400 m3/h 6 - 2600 m3/h 750 7 - 2800 m3/h 8 - 3000 m3/h 700 Static pressure [Pa] 650 Type: Motor: Test nr.: Date: DDE 12/9 1419H8 2817.* 04/03/03 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.8 IP 54 YES-IN F 72.1 dB(A) 600 550 71 69.3 70.5 70.1 69.9 69.1 500 68.9 450 66.8 400 69.7 68.2 67 67.5 66.8 68.4 67 66.2 350 64.7 63.3 300 250 66.9 65.9 61.3 66.6 64.1 200 63 64.8 59.6 63.2 150 54.2 100 1 50 55.9 57 54.3 2 59.7 60.6 61.8 7 5 3 8 6 4 0 0 500 1000 1500 2000 Flow rate [m3/h] 2500 3000 3500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 12/9 M9H8 1F 8QK SV LEGENDA : INPUT SIGNAL 34 CONSTANT AIRFLOW FILTER ALARM • SEGNALE / PORTATA COSTANTE : Corrispondenza tra il segnale ed il valore della portata costante. 1 0.00 – 1.25 1600 m3/h 77.57 mm Hst 2 1.25 – 2.51 1800 m3/h 72.00 mm Hst 3 2.51 – 3.76 2000 m3/h 67.50 mm Hst 4 3.76 – 5.02 2200 m3/h 63.20 mm Hst LEGEND : 5 5.02 – 6.27 2400 m3/h 59.90 mm Hst 6 6.27 – 7.53 2600 m3/h 55.75 mm Hst • INPUT SIGNAL / CONSTANT AIRFLOW : Correspondence between input signal and the value of the constant airflow. 7 7.53 – 8.78 2800 m3/h 55.33 mm Hst 8 8.78 – 10.04 3000 m3/h 54.10 mm Hst • SEGNALE / ALLARME FILTRO : Corrispondenza tra il segnale e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • INPUT SIGNAL / FILTER ALARM : Correspondence between input signal and the max static pressure reachable without alarm filter operating. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 1000 COD. 610551 950 Constant flow rate curves : 1 - 1600 m3/h 900 2 - 1800 m3/h 850 3 - 2000 m3/h 4 - 2300 m3/h 800 5 - 2600 m3/h 6 - 2900 m3/h 750 7 - 3200 m3/h 72.9 8 - 3500 m3/h 700 71.7 650 Static pressure [Pa] Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 600 69.9 550 70.2 69.3 69.1 500 69.6 67.3 68.3 450 70.1 68.4 67.4 67.7 67.3 400 64.5 63.5 63 300 66 65.2 66.2 63.6 62.7 65 64.8 63.8 61.5 250 66.4 65.3 62.4 61.6 59.7 53.6 53.7 52.6 100 1 2 50 3 500 1000 1500 2000 Amp. Max: Prot.: T.H.: Ins. CI.: 7.3 IP 54 YES-IN F 56.9 54.1 4 5 57.5 6 62 60.5 8 7 0 0 750 230 50 6 61.5 58.6 57.5 150 Watt: Volt: Hz: Poles: mF: 64.1 60.5 58.1 200 DDE 12/12 1419H8 2818.* 05/03/03 68.1 dB(A) 65.3 350 Type: Motor: Test nr.: Date: 2500 Flow rate [m3/h] 3000 3500 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 12/12 M9H8 1F 8QK SV LEGENDA : • SEGNALE / PORTATA COSTANTE : Corrispondenza tra il segnale ed il valore della portata costante. INPUT SIGNAL CONSTANT AIRFLOW FILTER ALARM 1 0.00 – 1.25 1600 m3/h 71.90 mm Hst 2 1.25 – 2.51 1800 m3/h 65.20 mm Hst 3 2.51 – 3.76 2000 m3/h 62.00 mm Hst 4 3.76 – 5.02 2300 m3/h 60.50 mm Hst LEGEND : 5 5.02 – 6.27 2600 m3/h 55.50 mm Hst 6 6.27 – 7.53 2900 m3/h 47.80 mm Hst • INPUT SIGNAL / CONSTANT AIRFLOW : Correspondence between input signal and the value of the constant airflow. 7 7.53 – 8.78 3200 m3/h 45.00 mm Hst 8 8.78 – 10.04 3500 m3/h 40.25 mm Hst • SEGNALE / ALLARME FILTRO : Corrispondenza tra il segnale e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. • INPUT SIGNAL / FILTER ALARM : Correspondence between input signal and the max static pressure reachable without alarm filter operating. 35 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1000 COD. 610546 950 Constant flow rate curves : 1 - 2500 m3/h 900 2 - 2800 m3/h 850 3 - 3100 m3/h 4 - 3400 m3/h 800 5 - 3700 m3/h 6 - 4000 m3/h 750 7 - 4300 m3/h 8 - 4600 m3/h 700 73.2 650 Type: Motor: Test nr.: Date: DDE 12/12 1419H9 S2354.* 06/06/03 Watt: Volt: Hz: Poles: mF: 1050 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 7.9 IP 54 YES-IN F Static pressure [Pa] 71.8 600 72.3 550 69.8 500 69.4 69 450 400 68.8 68.2 67 65.8 68.2 67.8 68.4 67.4 66.9 66.4 350 66.5 300 67.5 dB(A) 64.9 65.3 62.8 67.1 65.3 66 66.7 63.4 250 63.6 60.1 62.9 64.3 65.6 66.3 200 61.8 61.4 56.6 150 56.3 64.8 62.9 59.7 65 62.7 100 64.7 59.6 52.9 50 1 2 57.1 3 0 500 1000 1500 2000 2500 3000 Flow rate [m3/h] 6 3500 64.5 60.7 5 4 0 62.4 4000 7 8 4500 5000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 12/12 M9H9 1F 8QK D DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 2500 m3/h 67.25 mm Hst 2800 m3/h 66.00 mm Hst 3100 m3/h 55.25 mm Hst 3400 m3/h 54.50 mm Hst 3700 m3/h 48.50 mm Hst 4000 m3/h 46.00 mm Hst 4300 m3/h 44.50 mm Hst 4600 m3/h 32.50 mm Hst ON 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PORTATA COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della portata costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 36 • DIP-SWITCH POSITION / CONSTANT AIRFLOW : Correspondence between dip-switches position and the value of the constant airflow. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max static pressure reachable without alarm filter operating. VENTILATORI A PRESSIONE COSTANTE CONSTANT PRESSURE FANS QUOTE DIMENSIONALI - DIMENSIONS Taglia Size 9/7 TIGHT 9/9 TIGHT 9/7 9/9 Motore Motor 370 W 550 W 370 W 550 W 370 W 550 W 370 W 550 W 10/8 tutti i motori - all motors 10/10 tutti i motori - all motors 12/9 tutti i motori - all motors 12/9 1050 W 12/12 tutti i motori - all motors 12/12 1050 W A B C E F G H L P mm mm mm mm mm mm mm mm mm 326 326 326 326 387 387 387 387 443 443 521 521 521 521 185 185 185 185 215 215 215 215 249 249 294 294 294 294 262 262 262 262 262 262 262 262 289 289 341 341 341 341 167 167 167 167 160 160 160 160 178 178 213 213 213 213 318 318 318 318 380 380 380 380 425 425 491 491 491 491 155 155 155 155 185 185 185 185 203 203 230 230 230 230 232 232 298 298 232 232 298 298 265 331 309 309 395 395 349 364 393 396 349 364 393 396 378 421 401 400 487 486 117 132 95 98 117 132 95 98 113 90 92 91 92 91 ORIENTAMENTO SCATOLA MOTORE - MOTOR BOX ORIENTATION 38 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber 900 A COD. 610553 Constant Pressure Curves 850 Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m A -- Fan Max Working Limit 1 - 500 Pa 800 2 - 450 Pa 3 - 400 Pa 750 4 - 350 Pa 5 - 300 Pa 700 6 - 250 Pa 7 - 200 Pa 73.1 8 - 150 Pa 650 600 71.8 Static pressure [Pa] 1 Type: Motor: Test nr.: Date: DDE 10/10 1419K1 S2394.* 29/07/03 Watt: Volt: Hz: Poles: mF: 550 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.1 IP 54 YES-IN F 550 71.6 2 500 450 70.1 3 4 400 70.9 72.6 70 70.1 68.4 68.9 68.7 67.2 68.7 68.4 67.4 68.1 67 5 350 65.8 66 67.1 64.7 300 6 68.3 dB(A) 63.3 63.2 63.6 250 62.1 7 65 58.2 58 8 150 55.1 60.4 55 67.7 72.3 62.9 61 58.5 200 65.4 60.6 62.6 67.5 69.6 100 50 65.7 0 0 500 1000 1500 2000 2500 Flow rate [m3/h] 3000 3500 4000 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 10/10 M9K1 1F 8PK D DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 150 Pa 3800 m3/h 200 Pa 3800 m3/h 250 Pa 3700 m3/h 300 Pa 3400 m3/h 350 Pa 3200 m3/h 400 Pa 3050 m3/h 450 Pa 2550 m3/h 500 Pa 2150 m3/h ON 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PRESSIONE COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della pressione costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la portata massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • DIP-SWITCH POSITION / CONSTANT PRESSURE : Correspondence between dip-switches position and the value of the constant pressure. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max airflow reachable without alarm filter operating. 39 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1000 A COD. 610557 Constant Pressure curves : A -- Fan Max Working Limit 900 1 - 400Pa K 2 - 350Pa K 3 - 300Pa K 4 - 250Pa K 800 5 - 200Pa K 74.9 6 - 150Pa K 7 - 100Pa K 8 - 50Pa K Static pressure [Pa] 700 72.4dB(A) 600 71.4 500 1 400 2 69.9 3 300 4 Type: Motor: Test nr.: Date: DDE 10/10 1419K0 S2552.* 04/02/04 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.8 IP 54 YES-IN F 5 200 6 70.5 7 100 8 0 0 500 1000 1500 2000 2500 Flow rate [m3/h] 3000 3500 4000 4500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 10/10 M9K0 1F 8PK D DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM ON 50 Pa 3700 m3/h 100 Pa 3900 m3/h 150 Pa 4060 m3/h 200 Pa 4120 m3/h 250 Pa 4110 m3/h 300 Pa 3800 m3/h 350 Pa 3650 m3/h 400 Pa 2680 m3/h 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PRESSIONE COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della pressione statica costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la portata massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 40 • DIP-SWITCH POSITION / CONSTANT PRESSURE : Correspondence between dip-switches position and the value of the constant static pressure. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max airflow reachable without alarm filter operating. Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 1200 COD. 610552 Constant Pressure Curves : 1100 A - Fan Max Working Limit 1 - 180 Pa K A 2 - 200 Pa K 1000 3 - 220 Pa K 4 - 240 Pa K 5 - 260 Pa K 6 - 280 Pa K 900 73 7 - 300 Pa K 8 - 320 Pa K 800 Type: Motor: Test nr.: Date: DDE 12/12 1419K0 S2632.* 06/04/04 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 6.7 IP 54 YES-IN F Static pressure [Pa] 72.1 700 70.3 dB(A) 600 69.1 500 67.6 66.8 400 8 62.4 7 63.4 62.7 65.5 64.8 65.8 6 300 5 4 3 200 2 62.7 1 55.5 58.7 56.9 62.9 61 100 0 0 500 1000 1500 2000 2500 Flow rate [m3/h] 3000 3500 4000 4500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DDE 12/12 1419K0 750W 8PK D DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 180 Pa 3950 m3/h 200 Pa 4000 m3/h 220 Pa 4050 m3/h 240 Pa 4000 m3/h 260 Pa 4030 m3/h 280 Pa 4000 m3/h 300 Pa 3940 m3/h 300 Pa 3970 m3/h ON 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PRESSIONE COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della pressione statica costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la portata massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • DIP-SWITCH POSITION / CONSTANT PRESSURE : Correspondence between dip-switches position and the value of the constant static pressure. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max airflow reachable without alarm filter operating. 41 VENTILATORI BINATI TWIN FANS DD2E 185/240 M9K2 Mot. 370W 0-10V cod. 610554 DD2E 7/7 M9K3 Mot. 750W 8QK cod. 610555 44 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 450 COD. 610554 Constant flow rate curves : 1 - 600 m3/h 400 2 - 1000 m3/h 3 - 1200 m3/h 4 - 1400 m3/h 5 - 1600 m3/h 6 - 1800 m3/h 350 7 - 2000 m3/h 8 - 2200 m3/h 62.2 300 61 Static pressure [Pa] 60.4 61.5 64.5 dB(A) 62 250 57.7 58.6 62.3 62.4 59.6 60.1 200 63.5 60.8 61.1 53.8 56 150 56.8 57.9 61.3 59.9 55 55.4 56.4 51.9 100 DD2E 185/240 1419K2 S2285.* 03/03/03 Watt: Volt: Hz: Poles: mF: 370 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 4.1 IP 54 YES-IN F 62.4 59.1 59.1 51.3 Type: Motor: Test nr.: Date: 60.6 56.8 57.7 59.2 3 43.6 50 4 1 55.7 52.7 48 2 54.8 5 57.1 6 7 59.2 8 0 0 500 1000 1500 Flow rate [m3/h] 2000 2500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DD2E 185/240 1419K2 1F 8QK DG + SQ SP DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 600 m3/h 37.00 mm Hst 1000 m3/h 35.25 mm Hst 1200 m3/h 33.87 mm Hst 1400 m3/h 33.00 mm Hst 1600 m3/h 30.90 mm Hst 1800 m3/h 28.00 mm Hst 2000 m3/h 25.00 mm Hst 2200 m3/h 20.06 mm Hst ON 1 2 3 4 5 6 LEGENDA : • POSIZIONE DIP-SWITCH / PORTATA COSTANTE : Corrispondenza tra la posizione dei dip-switch ed il valore della portata costante. ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • POSIZIONE DIP-SWITCH / ALLARME FILTRO : Corrispondenza tra la posizione dei dip-switch e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. ON 1 2 3 4 5 6 LEGEND : ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 • DIP-SWITCH POSITION / CONSTANT AIRFLOW : Correspondence between dip-switches position and the value of the constant airflow. • DIP-SWITCH POSITION / FILTER ALARM : Correspondence between dip-switches position and the max static pressure reachable without alarm filter operating. 45 Zingonia Fan test laboratory AMCA 210/99 Fig. 12 10000 m3/h test chamber Air Density (g): 1.20 kg/m3 Installation type "B": free inlet, ducted outlet dB(A) free field noise measurements at 1 m 600 COD. 610555 Constant flow rate curves : 1 - 2100m3/h 550 2 - 2400 m3/h 3 - 2700 m3/h 500 4 - 3000 m3/h 5 - 3300 m3/h 6 - 3600 m3/h 7 - 3900 m3/h 450 8 - 4200 m3/h Static pressure [Pa] 400 68 69.2 Type: Motor: Test nr.: Date: DD2E 7/7 1419K3 S2360.* 12/06/03 Watt: Volt: Hz: Poles: mF: 750 230 50 6 Amp. Max: Prot.: T.H.: Ins. CI.: 7.55 IP 54 YES-IN F 67.1 69.3 350 66 69.6 67.4 300 65.3 67.4 65.8 64 250 70 dB(A) 66.8 69.7 68.2 66.4 62.6 63.6 64 200 70 67.7 61.1 61.9 68.6 64.1 150 69.1 66.8 61.3 64.7 58.7 68.6 67.4 61.2 100 66.1 62.2 68.7 66.8 56 50 1 68.1 61.4 57 58.4 2 4 1000 1500 2000 2500 Flow rate [m3/h] 3000 3500 67.6 7 8 6 0 500 64.6 5 3 0 66.6 62.8 4000 4500 This test data obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing. Data is not certified by AMCA. DD2E 7/7 1419K3 + FL 8QK SV DIP-SWITCH POSITION CONSTANT AIRFLOW FILTER ALARM 0 – 1.25 V 2100 m3/h 42.83 mm Hst 1.25 – 2.51 V 2400 m3/h 39.75 mm Hst 2.51 – 3.76 V 2700 m3/h 38.00 mm Hst 3.76 – 5.02 V 3000 m3/h 36.00 mm Hst 5.02 – 6.27 V 3300 m3/h 34.00 mm Hst 6.27 – 7.53 V 3600 m3/h 30.00 mm Hst 7.53 – 8.78 V 3900 m3/h 24.83 mm Hst 8.78 – 10.04 V 4200 m3/h 17.80 mm Hst LEGENDA : • SEGNALE (0-10V) / PORTATA COSTANTE : Corrispondenza tra il segnale (0-10V) ed il valore della portata costante. • SEGNALE (0-10V) / ALLARME FILTRO : Corrispondenza tra il segnale (0-10V) e la pressione statica massima raggiungibile senza l’entrata in funzione del filtro allarme. LEGEND : 46 • INPUT SIGNAL (0-10V) / CONSTANT AIRFLOW : Correspondence between imput signal (0-10V) and the value of the constant airflow. • INPUT SIGNAL (0-10V) / FILTER ALARM : Correspondence between imput signal (0-10V) and the max static pressure reachable without alarm filter operating. Nicotra Gebhardt worldwide SPAIN Ctra. Alcalá-Villar del Olmo, Km. 2,830 28810 Villalbilla-Madrid Phone +34-918846110 Fax +34-918859450 E-mail [email protected] c/.Coso, 67-75, esc. 1.a,1.oB 50001 Zaragoza Phone 00 34-976-290550 Fax 00 34-976-298127 E-mail [email protected] BELGIUM Haeghensgoed, 13 - 00/01 9270 Laarne Phone +32 (0) 9/336.00.01 Fax +32 (0) 9/336.00.05 E-mail [email protected] FRANCE 8 chemin des Mûriers BP 324 69745 Genas cedex. Phone 00 33 (0) 472790120 Fax 00 33 (0) 472790121 E-mail [email protected] SWEDEN Box 237 Kraketorpsgatan 30 43123 Mölndal Phone 00 46-31-874540 Fax 00 46-31-878590 E-mail [email protected] GREAT BRITAIN Unit D, Rail Mill Way Parkgate Business Park Rotherham South Yorkshire S62 6JQ Phone +044-01709-780760 Fax +044-01709-780762 E-mail [email protected] Monarch House 1-7 Smyth Road Bedminster Bristol Phone +44 (0)870 043 5207 Fax +44 (0)870 043 5212 E-mail [email protected] http://www.kiloheat.co.uk/ MALAYSIA Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing 43300 Seri Kembangan Selangor Phone +603-89612588 Fax +603-89618337 E-mail [email protected] Lot 1799, Bukit Belimbing Industrial Area Jalan Balakong 43300 Seri Kembangan Selangor Darul Ehsan Phone +603 8961 2588 Fax +603 8961 8337 E-mail [email protected] THAILAND 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road, Kwang Jomthong, Khet Jomthong, Bangkok 10150 Phone +662 476 1823-6 Fax +662 476 1827 E-mail [email protected] SINGAPORE No. 15 West Coast Highway # 04-08 Pasir Panjang Building Singapore 117861 Phone (065) 6265 1522 Fax (065) 6265 2400 E-mail [email protected] AUSTRALIA 47 Jesica Road, Campbellfield, VIC 3061 Phone +613-9357-7464 Fax +613-9357-8700 E-mail [email protected] INDIA Plot no 28f, Sector-31 Kasna, Greater Noida-201308 U.P. INDIA Phone +91-0120-4203400 Fax +91-0120-4203401 E-mail [email protected] CHINA 88 Tai‘An Road, XinQiao, ShiJi, Panyu Guangzhou 511450 PR CHINA Phone +86 (0)20-39960570 Fax +86 (0)20-39960569 E-mail [email protected] UNITED STATES 1503 W. Misty Breeze Cir Kaysville, UT 84037 Phone 001(801) 544-9909 Fax 001(801) 315-9400 Mobile 001(801) 694-0353 E-mail [email protected] Le caratteristiche delle macchine riportate nel presente catalogo, come dimensioni, prestazioni o altre, possono essere oggetto di modifica senza preavviso. I cataloghi Nicotra S.p.A. sono revisionati, quando necessario, con la pubblicazione di nuove edizioni. È importante che gli utenti si accertino di essere in possesso dell’ultima edizione in vigore. Qualunque utilizzo in campo aeronautico deve essere preventivamente comunicato a Nicotra SpA. The characteristics of the machines stated in this catalogue, like dimensions, performances and so on, can be modified without previous notice. Nicotra S.p.A. catalogues are revised, when necessary, with the issue of new editions; it is important for the user to be sure of possessing the last edition in force. Every application in aeronautics must be priorly communicated to Nicotra SpA. Nicotra Gebhardt GmbH Nicotra Gebhardt S.p.A Gebhardtstrasse 19-25 74638 Waldenburg, Germany Via Modena, 18 24040 Ciserano - Loc. Zingonia (BG), Italy Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail [email protected] Phone +39 035 873 111 Fax +39 035 884 319 E-mail [email protected] www.nicotra-gebhardt.com www.nicotra-gebhardt.com