VALVES CONTROLE PRESSION
PRESSURE CONTROL VALVES - VALVULAS LIMITADORAS DE PRESION
VALVE DE SEQUENCE
VS2C
SEQUENCE VALVE
VALVULA DE SECUENCIA
Code
Code
Código
P
MAX
bar
Type
Type
Tipo
L
L1
L2
BSP
Q
MAX
l/min
C
V
BSP
E
E1
E2
E3
H
S
kg
V1390.0640
3/8"
3/8"
35
350
VS2C 3/8" C
74
146
14
55
7
39
31
70
30
1,17
V1390.0660
V1390.0665
1/2"
3/4"
1/2"
3/4"
70
110
350
350
VS2C 1/2" C
VS2C 3/4" C
80
100
152
164
15
20
55
80
7
10
37
50
33
50
70
100
30
40
1,13
2,90
RESSORT - SPRING - MUELLE VS2C3/8” - 1/2”: A = 10:50 bar - B = 20:100 bar - C = 10:180 bar (Standard) - D = 50:250 bar - E = 80:300 bar
RESSORT - SPRING - MUELLE VS2C3/4”: C = 20:200 bar - d = 50:400 bar (Standard)
MONTAGE EN LIGNE
LINE MOUNTING
MONTAJE EN LINEA
MATERIEL - MATERIAL:ACIER - STEEL - ACERO
21
6.1
SCHEDA TECNICA/ TECHNICAL DATASHEET
VALVOLE DI SEQUENZA AD AZIONE DIRETTA
TIPO / TYPE
VS2C
SCHEMA IDRAULICO
HYDRAULIC DIAGRAM
SCHEMA DI MONTAGGIO
APPLICATION SCHEME
DIRECT ACTING
SEQUENCE VALVES
IMPIEGO:
Valvola utilizzata principalmente per far funzionare
in sequenza due cilindri: al raggiungimento di un
determinato valore di taratura, la valvola si apre e
va ad alimentare un secondo attuatore. La valvola
di ritegno permette il libero passaggio del flusso
nella direzione opposta. È indicata in impianti dove
la pressione sull’attuatore secondario sia limitata, in
quanto le pressioni si sommano.
MATERIALI E CARATTERISTICHE:
Corpo: acciaio zincato
Componenti interni: acciaio temprato termicamente
e rettificato
Guarnizioni: BUNA N standard
Tenuta: a cono guidato. Trafilamento trascurabile
MONTAGGIO:
Per l’impiego con due attuatori seguire le indicazioni di montaggio illustrate nello schema.
Per altri usi montare la valvola tenendo in considerazione che, al raggiungimento del valore di
pressione impostato, il flusso va da V in C, mentre
da C a V è libero.
A RICHIESTA
• Molle per diversi campi di taratura (vedi tabelle)
• Pressioni di taratura specifiche (CODICE/T 000
specificando il valore di taratura)
APPLICATIONS:
For use with 2 actuators, follow the mounting instructions indicated in the scheme. For different uses, mount
the valve keeping into consideration that, when the
valve reaches the setting pressure, the flow goes from V
towards C, whilst flow is free from C to V.
ON REQUEST
• different setting range (see the table)
• other setting available (CODE/T000 please specify
the desired setting)
Temperatura olio: 50°C - Viscosità olio: 30 cSt
Oil temperature: 50° C - Oil viscosity: 30 cSt
PRESSIONE/PORTATA
PRESSURE/FLOW
Δ P (BAR)
FLOW - Q (l/min)
VS2C 1/2”
Δ P (BAR)
VS2C 3/8”
V
Δ P (BAR)
C
MATERIALS AND FEATURES:
Body: zinc-plated steel.
Internal parts: hardened and ground steel.
Seals: BUNA N standard
Poppet type: minor leakage
FLOW - Q (l/min)
VS2C 3/4”
Δ P (BAR)
PERDITE DI CARICO
PRESSURE DROPS CURVE
USE AND OPERATION:
Sequence valve is used to feed 2 cylinders in
sequence: it provides flow to the secondary circuit
when a primary circuit function has been completed
reaching the pressure setting. Return flow is free. It’s
ideal for circuits with low pressure on the secondary
actuator as the pressures add to.
FLOW - Q (l/min)
FLOW - Q (l/min)
SCHEDA TECNICA/ TECHNICAL DATASHEET
CODICE
CODE
SIGLA
TYPE
PORTATA MAX
MAX FLOW
Lt. / min
RANGE DI PRESSIONE
PRESSURE RANGE
Bar
V0640
VS2C 3/8”
35
350
V0660
VS2C 1/2”
70
350
V0665
VS2C 3/4”
110
400
6
REGOLAZIONE - ADJUSTEMENT
CODICE/V • CODE/V
Volantino • Handknob
CODICE/PP • CODE/PP
Predisposizione alla piombatura • Arranged for sealing cap
CODICE/P • CODE/PP
SIGLA
TYPE
CODICE
CODE
Piombatura • Sealing cap
C-V
L
L1
L2
L3
L4
L5
L6
H
S
PESO/
WEIGHT
GAS
mm
mm
mm
mm
mm
mm
mm
mm
mm
Kg
V0640
VS2C 3/8”
G 3/8”
74
146
14
7
55
39
31
70
30
1,172
V0660
VS2C 1/2”
G 1/2”
80
152
15
7
55
37
33
70
30
1,130
V0665
VS2C 3/4”
G 3/4”
100
164
20
10
80
50
50
100
40
2,900
MOLLE - SPRINGS (VS2C 3/8” - 1/2”)
Campo di taratura
Incremento bar per riga
Taratura standard
Setting range (bar) Pressure increase (bar/turn) Standard setting
Q= 4l/min
(bar)
7
30
20 - 100
10 - 50*
12
75
10 - 180 standard
30
90
50 - 250
45
130
80 - 300
50
150
*Per tarature inferiori a 70 Bar: Q = 12 l/min *For setting less than 70 Bar: Q = 12 l/min
MOLLE - SPRINGS (VS2C 3/4”)
Campo di taratura
Incremento bar per riga
Taratura standard
Setting range (bar) Pressure increase (bar/turn) Standard setting
Q= 4l/min
(bar)
20 - 200
50 - 400 standard
40
160
80
180
162
VALVES CONTROLE PRESSION
PRESSURE CONTROL VALVES - VALVULAS LIMITADORAS DE PRESION
VALVE DE SEQUENCE AVEC ANNULLATION PRESSION PRIMAIRE
VSQ-APP
VSQ-APP
SEQUENCE VALVE WITH ZERO SETTING ON PRIMARY PRESSURE
VALVULA DE SECUENCIA CON ANULACION DE LA PRESION PRIMARIA
E1
L2
Ø8.5
H
V
E3
C
L3
E
L4
E2
C
L
S
L1
V
Code
Code
Código
C
V
BSP
BSP
Q
MAX
l/min
P
MAX
bar
Type
Type
Tipo
L
L1
L2
L3
L4
E
E1
E2
E3
H
S
kg
V1390.0642
3/8"
3/8"
35
250
VSQAP P 3/8" C
74
149
36
14
20
55
12
39
31
70
30
1,25
V1390.0662
V1390.0667
1/2 "
3/4 "
1/2 "
3/4 "
70
110
250
400
VSQAP P 1/2" C
VSQAP P 3/4" C
80 155
100 190
36
55
15
20
19
25
55
80
18
10
37
50
33
50
70
100
30
40
1,28
2,84
RESSO RT - SPRIN G - MUELLE : A = 10:50 bar - B = 20:100 bar - C = 10:180 bar(Standard) - D = 50:250 bar - E = 80:300 bar
MONTAGE EN LIGNE
LINE MOU NTING
MONTAJE EN LINEA
22
MATERIEL - MATERIAL :ACIER - STEEL - ACERO
6.2
SCHEDA TECNICA/ TECHNICAL DATASHEET
VALVOLE DI SEQUENZA AD ANNULLAMENTO PRESSIONE
PRIMARIA
TIPO / TYPE
VSQAPP
SCHEMA IDRAULICO
HYDRAULIC DIAGRAM
SCHEMA DI MONTAGGIO
APPLICATION SCHEME
SEQUENCE VALVES
IMPIEGO:
Valvola utilizzata principalmente per far funzionare
in sequenza due cilindri: al raggiungimento di un
determinato valore di taratura, la valvola si apre e
va ad alimentare un secondo attuatore. La valvola
di ritegno permette il libero passaggio del flusso nella direzione opposta. E’ insensibile alle contropressioni, pertanto consente di utilizzare la pressione
impostata dall’impianto per azionare entrambi gli
attuatori.
MATERIALI E CARATTERISTICHE:
Corpo: acciaio zincato
Componenti interni: acciaio temprato termicamente
e rettificato
Guarnizioni: BUNA N standard
Tenuta: a cono guidato. Trafilamento trascurabile
MONTAGGIO:
Per l’impiego con due attuatori seguire le indicazioni di montaggio illustrate nello schema.
Per altri usi montare la valvola tenendo in considerazione che, al raggiungimento del valore di
pressione impostato, il flusso va da V in C, mentre
da C a V è libero.
A RICHIESTA
• Molle per diversi campi di taratura (vedi tabelle)
• Pressioni di taratura specifiche (CODICE/T 000
specificando il valore di taratura)
MATERIALS AND FEATURES:
Body: zinc-plated steel
Internal parts: hardened and ground steel
Seals: BUNA N standard
Poppet type: minor leakage
APPLICATIONS:
For use with 2 actuators, follow the mounting instructions
indicated in the scheme. For different uses, mount the valve
keeping into consideration that, when the valve reaches
the setting pressure, the flow goes from V towards C, whilst
flow is free from C to V.
ON REQUEST
• different setting range (see the table)
• other setting available (CODE/T000 please specify the desired
setting)
PRESSIONE/PORTATA
PRESSURE/FLOW
FLOW - Q (l/min)
VSQAPP 1/2”
Δ P (BAR)
Δ P (BAR)
Δ P (BAR)
VSQAPP 3/8”
Temperatura olio: 50°C - Viscosità olio: 30 cSt
Oil temperature: 50° C - Oil viscosity: 30 cSt
FLOW - Q (l/min)
VSQAPP 3/4”
Δ P (BAR)
PERDITE DI CARICO
PRESSURE DROPS CURVE
USE AND OPERATION:
Sequence valve is used to feed 2 cylinders in sequence:
it provides flow to the secondary circuit when a primary
circuit function has been completed reaching the pressure
setting. Return flow is free. Being insensitive to back
pressures, it allows to use the circuit pressure to control
both the actuators.
FLOW - Q (l/min)
FLOW - Q (l/min)
SCHEDA TECNICA/ TECHNICAL DATASHEET
CODICE
CODE
SIGLA
TYPE
PORTATA MAX
MAX FLOW
Lt. / min
RANGE DI PRESSIONE
PRESSURE RANGE
Bar
V0642
VSQAPP 3/8”
35
350
V0662
VSQAPP 1/2”
70
350
V0667
VSQAPP 3/4”
110
400
6
REGOLAZIONE - ADJUSTEMENT
CODICE/V • CODE/V
CODICE/PP • CODE/PP
Volantino • Handknob
Predisposizione alla piombatura • Arranged for sealing cap
CODICE/P • CODE/PP
CODICE
CODE
SIGLA
TYPE
Piombatura • Sealing cap
C-V
L
L1
L2
L3
L4
L5
L6
H
H1
H2
S
PESO/
WEIGHT
GAS
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
Kg
V0642
VSQAPP 3/8”
74
149
55
12
20
36
14
39
31
70
30
1,250
V0662
VSQAPP 1/2”
G 1/2”
80
155
55
18
19
36
15
37
33
70
30
1,280
V0667
VSQAPP 3/4”
G 3/4”
100
190
80
10
25
55
20
50
50
100
40
2,844
G 3/8”
MOLLE - SPRINGS (3/4”)
MOLLE - SPRINGS (3/8” - 1/2”)
Incremento bar per riga
Campo di taratura
Taratura standard
Setting range (bar) Pressure increase (bar/turn) Standard setting
Q= 4l/min
(bar)
7
30
20 - 100
10 - 50*
12
75
10 - 180 standard
30
90
50 - 250
45
130
80 - 300
50
150
*Per tarature inferiori a 70 Bar: Q = 12 l/min *For setting less than 70 Bar: Q = 12 l/min
Campo di taratura
Incremento bar per riga
Taratura standard
Setting range (bar) Pressure increase (bar/turn) Standard setting
Q= 4l/min
(bar)
20 - 200
50 - 400 standard
40
160
80
180
164
VALVES CONTROLE PRESSION
PRESSURE CONTROL VALVES - VALVULAS LIMITADORAS DE PRESION
VALVE D’EXCLUSION HAUTE/BASSE PRESSION
VABP
VABP
Code
Code
Código
“HI-LOW” UNLOADING VALVE
VALVULA DE CONMUTACION “ALTA-BAJA” PRESION
Q
P
MAX MAX
l/min bar
AP
BP-U
T
BSP
BSP
BSP
V1290.0512 1/4"
V1290.0513 3/8"
3/8"
1/2"
1/2"
3/4"
40
65
V1290.0514 1/2"
3/4"
1"
100
Type
Type
Tipo
L
350 VABP 3/8" 100
350 VABP 1/2" 105
350 VABP 3/4" 140
L1
22
L3
L4
L5
L6
E
E1
E2
E3
H
S
kg
80
90
30
35
1,75
2,33
100
40
3,97
142
147
50
54
20
18
30
36
13
15
155
160
65
65
69
73
8,5
17
6,5
8
187
52,5
20
42,5
20
212
65
95
27
8
RESSORT “BP” - “BP” SPRING - MUELLE“BP”: B = 20:80 bar (Standard)
RESSORT “AP” - “AP” SPRING - MUELLE“AP”: d = 50:350 bar (Standard)
MONTAGE EN LIGNE
LINE MOUNTING
MONTAJE EN LINEA
L2
MATERIEL - MATERIAL:ACIER - STEEL - ACERO
11.1
SCHEDA TECNICA/ TECHNICAL DATASHEET
VALVOLE DI ESCLUSIONE ALTA-BASSA PRESSIONE
TIPO / TYPE
VABP
SCHEMA IDRAULICO
HYDRAULIC DIAGRAM
TWO PUMP “HI-LOW”
UNLOADING VALVES
IMPIEGO:
In un circuito alimentato da due pompe in parallelo,
valvola utilizzata per mandare a scarico la pompa di
maggior portata al raggiungimento di un determinato
valore di taratura. Da questo momento in poi l’attuatore lavora con la pompa di minor portata a pressione
maggiore, consumando meno energia.
USE AND OPERATION:
This valve is used in a 2 parallel-working pumps circuit in
order to release the excess of the higher flow pump to the
tank when this gets the required pressure setting. Since
this moment and on the actuator works with the lower flow
pumps at higher pressure, consuming less energy.
MATERIALI E CARATTERISTICHE:
Corpo: acciaio zincato
Componenti interni: acciaio temprato termicamente e
rettificato
Guarnizioni: BUNA N standard
Tenuta: a cono guidato. Trafilamento trascurabile
MATERIALS AND FEATURES:
Body: zinc-plated steel
Internal components: grounded and hardened steel
Seals: BUNA N standard
Tightness: minor leakage
MONTAGGIO:
Collegare BP alla pompa di maggior portata, AP alla
pompa di minor portata, T allo scarico, U all’utilizzo e
M all’eventuale manometro.
APPLICATIONS:
Connect BP to the higher flow pump, AP to the lower flow
pump, T to the tank, M to the eventual manometer and U
as for necessity.
PERDITE DI CARICO
PRESSURE DROPS CURVE
Temperatura olio: 50°C - Viscosità olio: 30 cSt
Oil temperature: 50° C - Oil viscosity: 30 cSt
VABP 3/8” - VABP 1/2”
BP
BP
U 1/2”
VABP 3/4”
BP
U 3/4”
U 3/8”
BP
T 3/8”
BP
T 1/2”
BP
T 3/4”
SCHEDA TECNICA/ TECHNICAL DATASHEET
11
CODICE
CODE
PORTATA MAX
MAX FLOW
Lt. / min
SIGLA
TYPE
AP
BP
PRESSIONE MAX
MAX PRESSURE
Bar
PESO
WEIGHT
Kg
60
300
1,748
T
V0512
VABP 3/8”
20
40
V0513
VABP 1/2”
30
50
80
350
2,342
V0514
VABP 3/4”
40
80
120
350
3,970
sede tappata per l’eventuale
applicazione di un manometro
MOLLE STANDARD - STANDARD SPRINGS
capped port for eventual
manomether montage
CODICE
CODE
SIGLA
TYPE
VALVOLA
BP
AP
VALVE
(BAR)
(BAR)
VABP 3/8”
20-80
50-350
VABP 1/2”
20-80
50-350
VABP 3/4”
20-80
50-330
AP
BP
U
T
L
L1
L2
L3
L4
L5
L6
L7
H1
H2
H3
H
S
GAS
GAS
GAS
GAS
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
V0512
VABP 3/8”
G 1/4” G 3/8”
G 3/8” G 1⁄2”
100
142
155
50
30
20
13
69
65
8,5
6,5
80
30
V0513
VABP 1/2”
G 3/8” G 1/2”
G 1/2” G 3/4”
105
147
160
54
36
18
15
73
65
17
8
90
35
V0514
VABP 3/4”
G 1/2” G 3/4”
G 3/4” G 1”
140
187
212
52,5
42,5
20
20
95
65
27
8
100
40
224