INGETEAM ENERGY S.A. Avda. Ciudad de la Innovación nº13 31621 Sarriguren (Navarre) Tel : +34 948 288000 Fax : +34 948 288001 www.ingeteam.es DECLARATION OF CONFORMITY Manufacturer: INGETEAM ENERGY S.A. Avda. Ciudad de la Innovación nº 13 E-31621 Sarriguren (Navarre). SPAIN Phone +34 948288000 / Fax +34 948288001 We hereby declare the conformity of our products Brand/Model: INGECON® SUN 2.5 INGECON® SUN 3.3 INGECON® SUN 2.5 TL INGECON® SUN 3 TL INGECON® SUN 3.3 TL INGECON® SUN 3.45 TL Are conforming to the provisions of the following harmonised standards: REF:AAY2006IFB01 INGECON® SUN 3.68 TL EMC: EN 61000-6-3:2001 + A11(2004) (Residential Environments) Immunity: EN 61000-6-2:2001 (Industrial Environments) Harmonics: EN 61000-3-2:2000 + A2 (2005) Flickers: EN 61000-3-3:1995 + A1 (2001) Electrical Security: UNE EN 50178:1998 Therefore fulfils with the safety provisions for people and things required by the following Council Directives: Low Voltaje Directive: 2006/95/CE EMC Directive: 2004/108/CE In case that our supplies are incorporated into equipment subject to the Directive 89/392/CE and its modifications, these products cannot be put into service without the prior Declaration of fulfilment of the above mentioned Directives and Quality Standards by the equipment to which they are to be incorporated. Sarriguren, April 2010 Mr. Juan Carlos Jadraque Head of PV Area Ingeteam Energy S.A. Inscrita en el Registro Mercantil de Navarra, Tomo 19, Folio 179, Hoja NA-314 ± Inscripción 27.9.90 - CIF A-31-270853 REV: _ Emission: INGETEAM ENERGY S.A. Avda. Ciudad de la Innovación nº13 31621 Sarriguren (Navarre) Tel : +34 948 288000 Fax : +34 948 288001 www.ingeteam.es DECLARATION OF CONFORMITY Manufacturer: INGETEAM ENERGY S.A. Avda. Ciudad de la Innovación nº 13 E-31621 Sarriguren (Navarre). SPAIN Phone +34 948288000 / Fax +34 948288001 We hereby declare the conformity of our products Brand/Model: INGECON® SUN 3.8 TL INGECON® SUN 4.6 INGECON® SUN 4.6 TL INGECON® SUN 5 INGECON® SUN 5 TL INGECON® SUN 6 TL REF:AAY2006IFB02 Are conforming to the provisions of the following harmonised standards: EMC: EN 61000-6-3:2001 + A11(2004) (Residential Environments) Immunity: EN 61000-6-2:2001 (Industrial Environments) Harmonics: EN 61000-3-12:2005 Flickers: EN 61000-3-11:2000 Electrical Security: UNE EN 50178:1998 Therefore fulfils with the safety provisions for people and things required by the following Council Directives: Low Voltaje Directive: 2006/95/CE EMC Directive: 2004/108/CE In case that our supplies are incorporated into equipment subject to the Directive 89/392/CE and its modifications, these products cannot be put into service without the prior Declaration of fulfilment of the above mentioned Directives and Quality Standards by the equipment to which they are to be incorporated. Sarriguren, April 2010 Mr. Juan Carlos Jadraque Head of PV Area Ingeteam Energy S.A. Inscrita en el Registro Mercantil de Navarra, Tomo 19, Folio 179, Hoja NA-314 ± Inscripción 27.9.90 - CIF A-31-270853 REV: _ Emission: INGETEAM ENERGY S.A. Avda. de la Innovación E-31621 Sarriguren (Navarre) SPAIN Tel : +34 948 288000 Fax : +34 948 288001 www.ingeteam.com CERTIFICATE OF CONFORMITY Manufacturer: INGETEAM ENERGY S.A. Avda. Ciudad de la Innovación nº 13 E-31621 Sarriguren (Navarre). SPAIN Phone +34 948288000 / Fax +34 948288001 We hereby declare that our product Brand/Model INGECON® SUN: INGECON® SUN 2.5 TL INGECON® SUN 3 TL INGECON® SUN 3.3 TL INGECON® SUN 3.8 TL INGECON® SUN 4.6 TL INGECON® SUN 5 TL INGECON® SUN 6 TL Fullfils with the safety provisions for people and things required by the following Council Directives: 2006/95/CE Low Voltage Directive 2004/108/CE Electromagnetic Compatibility Directive Complying with this directives allows this equipments to be marked CE. Fullfils with requirements of the standards: CEI 11-20 (2000) CEI 11-20 V1 (2004) RTC alle rete BT di Enel Distribuzione Includes the device: RCD Type B in compliance with IEC 60755 and tested according the provisions of VDE0126-1-1. Sarriguren, September 2009 Inscrita en el Registro Mercantil de Navarra, Tomo 19, Folio 179, Hoja NA-314 ± Inscripción 27.9.90 - CIF A-31-270853 INGECON SUN LITE XX TL DATI TECNICI PER COMPILAZIONE ALLEGATO “O” DELLA “GUIDA PER LE CONNESSIONI ALLA RETE ELETTRICA DI ENEL DISTRIBUZIONE” Versione 1 Tipo Convertitore CC/CA Marca Ingeteam versione firmware: Da tabella La limitazione della componente continua della corrente immessa in rete è ottenuta mediante: Ingecon Sun 4,6TL Ingecon Sun 5TL Ingecon Sun 6TL G8P1A4P12VDC 30A G8P1A4P12VDC 30A G8P1A4P12VDC 30A G8P1A4P12VDC 30A G8P1A4P12VDC 30A G8P1A4P12VDC 30A G8P1A4P12VDC 30A 2500 3000 3300 3800 4600 5000 6000 230 230 230 230 230 230 230 1 1 1 1 1 1 1 Contributo alla Corrente di CC [A] 2700 3000 3700 3900 5000 5500 6000 Fattore di potenza Pnom [W] OMRON OMRON OMRON OMRON OMRON OMRON OMRON DI (Modello) Prot. interna Prot. interna Prot. interna Prot. interna Prot. interna Prot. interna Prot. interna Tensione di alimentazione [V] Ingecon Sun 3,8TL AAY1000 AAY1000 AAY1000 AAY1000 AAY1000 AAY1000 AAY1000 Potenza nominale HP [W] Ingecon Sun 3,3TL DI Ingecon Sun 3TL Limitazione corrente continua Ingecon Sun 2,5TL SW Version (Converter) Ƒ protezione implementata internamente al sistema di controllo del convertitore Modello Iscritta alla CCIA, REA: RA-190150, Partita IVA e C.F. 02306720398 3.3 Caratteristiche degli apparati di conversione statici 16,3 18,3 21,5 23,5 30 32,6 35,2 (*) combinato con fusibili o interruttore automatico esterni come da manuale di installazione Ingeteam S.r.l. Via Emilia Ponente, 232 - 48014 Castel Bolognese (RA) – ITALY Tel. + 39 0546 651490 Fax +39 0546 655391 e-mail [email protected] www.ingeteam.it Pagina 1 di 2 3.5 Caratteristiche degli organi di manovra principali (**) Dispositivo di Interfaccia Modello Numero poli Tipo vedi tabella 2 Relè Iscritta alla CCIA, REA: RA-190150, Partita IVA e C.F. 02306720398 3.6 Caratteristiche delle protezioni di interfaccia (**) Marca Modello versione firmware: integrata in altri apparati: Numero apparati Numero dispositivi associati Ingeteam Medesimo dell'inverter Medesima dell'inverter Ƒ SI (interno all'inverter) Numero di inverter installati Numero di inverter installati (**) Dati validi solo per SPI interno all'inverter. Per impianti composti da più di tre inverter e/o potenza maggiore di 20kW, deve essere installato un SPI esterno. Ingeteam S.r.l. Via Emilia Ponente, 232 - 48014 Castel Bolognese (RA) – ITALY Tel. + 39 0546 651490 Fax +39 0546 655391 e-mail [email protected] www.ingeteam.it Pagina 2 di 2 PROTEZIONE ESECUZIONE 15.1 Massima tensione unipolare 15.2 Minima tensione unipolare 15.3 Massima frequenza unipolare 15.4 Minima frequenza unipolare 15.5 Derivata frequenza unipolare VALORE DI TARATURA 273 V TEMPO DI INTERVENTO 80 ms 186 V 80 ms 49,7 Hz < 100 ms 50,3 Hz < 100 ms Hz/s Iscritta alla CCIA, REA: RA-190150, Partita IVA e C.F. 02306720398 TARATURE DELLE PROTEZIONI DI INTERFACCIA Ingeteam S.r.l. Via Emilia Ponente, 232 - 48014 Castel Bolognese (RA) – ITALY www.ingeteam.com Tel. + 39 0546 651490 Fax +39 0546 655391 e-mail [email protected] Pagina 1 di 1 INGETEAM ENERGY S.A. Avda. de la Innovación E-31621 Sarriguren (Navarra) SPAIN Tel : +34 948 288000 Fax : +34 948 288001 www.ingeteam.com PROTEZIONE CONTRO CORRENTI DI GUASTO CONTINUE Ingeteam Energy SA, con sede contrale in Avda. Ciudad de la Innovacion, nº13, 31621 SARRIGUREN SPAIN (in seguito Ingeteam), dichiara che la famiglia di inverter monofasi senza trasformatore di bassa frequenza, Ingecon Sun LITE TL integra nel proprio sistema di controllo hardware e software la seguente protezione: 3URWH]LRQH FRQWUR O¶LQLH]LRQH GL FRUUHQWL GL JXDVWR FRQWLQXH secondo IEC 60755/A2. Tale protezione inoltre è conforme alla norma VDE 0126-1-1. I test reports a verifica della conformità, sono stati prodotti da un laboratorio indipendente (LABEIN TECNALIA) e la dichiarazione di conformità è stata HPHVVDGDOO¶LVWLWXWRWHGHVFR%* Ingeteam dichiara quindi di avere adottato tutti gli accorgimenti tecnici necessari ad DVVLFXUDUHTXDQWRGHWWR/¶LQLH]LRQHGLFRUUHQWHFRQWLQXDGLJXDVWRDWHUUDqHYLWDWD secondo quanto richiesto dalla norma CEI 64-8 al punto 712.413.1.1.1.2. Sarriguren, Maggio 2010