TEST REPORT
EN 12975-2: 2006: Thermal solar systems and components - Solar collectors –
Part2: Test methods
Impianti solari termici e loro componenti - Collettori solari - Parte 2: Metodi di prova
Report Reference No./ Numero rapporto ..:
M1.10.SOLT.0400/40581-rev01
Date of issue / Data di emissione ................:
2010-08-06
Total number of pages / N° tot. di pagine.... :
23
Testing Laboratory / Laboratorio di prova ..:
Eurofins – Modulo Uno S.p.A.
Address / Indirizzo ..................................:
Strada Savonesa, 9 - 15050 Rivalta Scrivia (AL) – Italy
Applicant’s name / Nome del richiedente ...:
Janus Energy S.r.l.
Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy
Address / Indirizzo ..................................:
Test specification / Specifiche di prova
Standard / Norma ...................................:
Non-standard test method ..................:
EN 12975-2:2006
N/A
Metodo di prova non standard
Scope of the test / Scopo della prova
To determine the steady-state and quasi-dynamic thermal performance of glazed and unglazed liquid heating
solar collectors, within the scope of EN 12975-1:2006 “Thermal solar systems and components – Solar
collectors - Part 1: General requirements”.
Caratterizzazione delle prestazioni termiche in condizioni stazionarie e quasi dinamiche, nello scopo della norma EN 12975-1: 2006: Sistemi
e componenti solari termici – Collettori solari – Parte 1: Requisiti generali”.
Test item description ........................: Unglazed liquid heating solar collector.
Descrizione dell’oggetto in prova
Collettore solare non vetrato per il riscaldamento di liquidi
Trade Mark .........................................:
Marchio
Manufacturer / Costruttore..................:
Janus Energy S.r.l.
Address / Indirizzo ..................................:
Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy
Model/Type reference / Modello .............:
SUNNYDAY – SF2000
Date of receipt of the test item............:
2010/03/17
Data di ricevimento dell’oggetto in prova
Testing period / Periodo di prova ................:
2010/03/29 ÷ 2010/07/30
This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory The test results presented
in this report relate only to the object tested. Eurofins Modulo Uno S.p.A. takes no responsibility for and will not assume liability for
damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia. I risultati esposti in
questo rapporto di prova si riferiscono esclusivamente all’oggetto testato. Eurofins Modulo Uno S.p.A. non assume alcuna responsabilità per danni derivanti
dall’interpretazione del lettore del materiale riprodotto al di fuori del suo contesto.
This Test Report cancel and replace the previous review / Il presente Rapporto di Prova annulla e sostituisce la revisione precedente
01
P.Ind. Bruno Vaisitti
Ing. Giovanni Bellenda
Revision n°
Test responsible
Head of thermal solar testing dept.
0
P.Ind. Bruno Vaisitti
Ing. Giovanni Bellenda
Revision n°
Test responsible
Head of thermal solar testing dept.
Summary / Sommario
GENERAL INFORMATION / INFORMAZIONI GENERALI ______________________________3
Description of test item construction / Descrizione della costruzione dell’oggetto in prova 4
Test summary statement / Attestazione di prova__________________________________8
Record of test sequence and summary of main results / Sequenza delle prove ___________8
TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici
__________________________________________________________________________9
TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici10
TAB. 2: High temperature resistance / Resistenza alle alte temperature _______________11
TAB. 3A: Exposure test / Prova di esposizione ____________________________________12
TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione __________13
TAB. 4: External thermal shock test / Prova dello shock termico esterno _______________14
TAB. 5: Internal thermal shock test / Prova dello shock termico interno ________________15
TAB. 6: Rain penetration test / Prova di penetrazione della pioggia ___________________16
TAB. 7: Freeze resistance test / Prova di resistenza al gelo __________________________17
TAB. 8: Mechanical load test / Prova di carico meccanico ___________________________18
TAB. 9: Final inspection / Ispezione finale _______________________________________19
TAB. 10: Thermal performance / Prestazioni termiche______________________________20
Test results / Risultati di prova ________________________________________________20
POWER OUTPUT per collector unit / Potenza resa per unità di collettore ______________20
Incidence Angle Modifier (IAM) at 50° / Fattore di angolo di incidenza a 50° ____________23
Time constant τc / Costante di tempo
[s]_______________________________________23
Effetcive thermal capacity / Capacità termica effettiva
Report No. M1.10.SOLT.0400/40581-rev01
[kJ/K] ______________________23
Page 2 of 23
GENERAL INFORMATION / INFORMAZIONI GENERALI
General remarks / Note generali:
•
This publication may be reproduced in whole or in part for non-commercial purposes as long as Eurofins
Modulo Uno S.p.A. is acknowledged as copyright owner and source of the material and only with the
written permission.
Questa pubblicazione può essere riprodotta per intero o parzialmente per scopi non commerciali a condizione che Eurofins Modulo
Uno S.p.A. sia riconoscibile come proprietaria dei diritti d’autore e fonte del materiale e solo con autorizzazione scritta.
• The test results presented in this report relate only to the object tested.
I risultati esposti in questo rapporto di prova si riferiscono esclusivamente all’oggetto testato.
• This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory.
Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia.
• "(see annex #)" refers to additional information included in the report.
“(vedi allegato #)” è un riferimento ad informazioni aggiuntive incluse al rapporto
• "(see tab. #)" refers to a table included in the report.
“(vedi tab.#)” è un riferimento ad una tabella inclusa al rapporto
• Throughout this report a comma (point) is used as the decimal separator.
In questo rapporto di prova il punto è utilizzato come separatore decimale
Testing location(s):
Eurofins - Modulo Uno S.p.A.
Sito(i) di prova
Strada Comunale Savonesa, 9
15050 Rivalta Scrivia (AL) – Italy
Latitude / Latitudine: 44° 52’ N
Longitude / Longitudine: 08° 48’ E
Tel. +39 011 2222225
Fax +39 011 2222226
e-mail: [email protected]
web: www.product-testing.eurofins.com
Tests performed (name of test
and test clause) ........................ :
EN 12975-2
Prove eseguite (nome ed articolo del test)
Possible test case verdicts / Esiti di prova possibili:
- test case does not apply to the test object / il requisito non è applicabile all’oggetto in prova ..........:
N/A
- test object does meet the requirement / l’oggetto in prova rispetta il requisito ..............................:
Pass (P)
- test object does not meet the requirement / l’oggetto in prova non rispetta il requisito ...................:
Fail (F)
Abbreviations used in this report / Abbreviazioni usate in questo rapporto:
Manufacturer’s Specification / Specifica fornita dal costruttore ......................................................:
MS
Equipment under Test / Oggetto in prova...................................................................................:
E.u.T.
Meteo parameters
Ambient or surrounding air temperature [°C] ........ ................................................................:
-2
Ta or ta
Global hemispherical solar irradiance [Wm ] .......................................................................:
G*
Wind speed [m/s]...................................................................................................................:
u
Definition of efficiency
Thermal output power of collector ................................................................................ [W] :
2
A
2
G”
Reference area ............................................................................................................. [m ] :
Net irradiance .......................................................................................................... [W/m ] :
Report No. M1.10.SOLT.0400/40581-rev01
Page 3 of 23
Description of test item construction / Descrizione della costruzione dell’oggetto in prova
Orderer / Richiedente ............................. :
Janus Energy S.r.l.
Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy
Expeller / Rivenditore ............................. :
Janus Energy S.r.l.
Manufacturer / Costruttore ..................... :
Janus Energy S.r.l.
Sampling procedure / Procedura di
campionamento........................................ :
produzione
Random sampling from production / Campionamento casuale dalla
Prototype submitted by client / Prototipo fornito dal cliente
Brand name / Nome commerciale ............ :
SUNNYDAY – SF2000
Serial number / Numero di serie .............. :
--
Lab. Identification code / Codice
identificativo del laboratorio ......................... :
10.0547
Picture of marking plate / Immagine dell’etichetta:
Photograph(s) of the E.u.T. / Foto dell’oggetto in prova
Report No. M1.10.SOLT.0400/40581-rev01
Page 4 of 23
Ratings / Dati tecnici nominali
Max working temperature [°C] /
Massima temperatura operativa [°C]
............................ :
Max working pressure [bar] / Massima pressione operativa [bar] .................................. :
2
Rated (recommended) flow rate [l/m h] / Portata nominale (consigliata) [l/m h] ............. :
2
93
3
50
Collector / Collettore
Manufacturer / Costruttore ............................:
Janus Energy S.r.l.
Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy
Model / Modello ...........................................:
SUNNYDAY – SD 2000F
Glazed flat plate / Vetrato piano
Vacuum tube – Heat pipe single glass tube / Tubi evacuati – Tubo di calore singola copertura vetrata
Vacuum tube – Heat pipe double glass tube / Tubo di calore doppia copertura vetrata
Collector type / Tipo
di collettore ................:
Vacuum tube – U Tube / Tubi evacuati – Tubi a U
Vacuum tube – filled with water / Tubi evacuati riempiti d’acqua
Without covering – unglazed / Scoperto - non vetrato
Other / Altro
Serial product / Prodotto di serie ............................................................................. :
YES / SÌ
Drawing number / N° di disegno ............................................................................ :
--
Serial number / Numero di serie ............................................................................. :
--
Date when manufactured / data di costruzione ........................................................
--
Collector loop flow range [kg/s] / Campo di flusso del circuito collettore [kg/s] ................... :
--
Operating pressure [kPa] / Pressione di esercizio ..................................................... :
< 300
NO
2
Stagnation temperature at 1000 W/m and 30°C ambient temperature [°C] /
Temperatura di stagnazione a 1000 W/m2 e 30°C di te mperature ambiente [°C] ................................ :
Collector mounting / Montaggio del collettore ............................................................ :
Support metal frame material (if any) Materiale del supporto metallico
N° of collectors /
N° di collettori
(se esistente)
........ :
............................................................................. :
-on plastic support /
Polymeric
3
Gross length [mm] / Lunghezza lorda [mm] ............................................................... :
2040
Gross width [mm] / Larghezza lorda [mm] ................................................................. :
353 x 3 = 1059
Gross height [mm] / Altezza lorda [mm] ................................................................... :
5
2
Gross area [m ] / Superficie lorda [m2] ..................................................................... :
2
Aperture area [m ] / Superficie di apertura [m2] ........................................................... :
2
2.2
2.16
Absorber area [m ] / Superficie assorbitore [m2].......................................................... :
1.86
Weight empty [kg] / Peso a vuoto [kg] ..................................................................... :
1.7 x 3 = 5.1
Weight without glazing [kg] / Peso senza copertura vetrata [kg]..................................... :
--
Fluid capacity [l] / Capacità di contenimento di fluido [l] ................................................... :
2.37 x 3 = 7.1
Report No. M1.10.SOLT.0400/40581-rev01
su supporto
plastico
Page 5 of 23
Number of covers / Numero di coperture
0
Cover material / Materiale copertura
--
Cover thickness [mm] / Spessore copertura [mm]
--
Cover solar transmittance [%] / Trasmittanza solare della copertura [%] .......................... :
--
Absorber material / Materiale assorbitore :
Polypropylene / Polipropilene
Absorber’s dimensions / Dimensioni dell’assorbitore ................................................... :
310 x 2000 x 3
Absorber’s thickness [mm] / Spessore dell’assorbitore [mm] ........................................
3
Absorber dry weight [kg] / Peso a vuoto dell’assorbitore [kg] ......................................... :
--
Absorber – Fin width [mm] / Larghezza alette dell’assorbitore [mm] ................................ :
--
Absorber – Fin thickness [mm] / Spessore alette dell’assorbitore [mm] ........................... :
--
Solar absorptance α / Fattore di assorbimento solare α ............................................... :
--
Hemispherical emittance ε / Emittanza emisferica ε .................................................. :
--
Surface treatment / Trattamento superficiale.............................................................. :
--
Construction type / Tipo di costruzione
Unglazed – Extruded
Polypropylene / Scoperto –
.............................................................. :
Polipropilene estruso
Number of risers / Numero di tubi di innalzamento ........................................................ :
3 x 37 = 111
Riser diameter or dimensions / Dimensioni o diametro dei tubi di innalzamento .................. :
--
Distance between risers / Distanza tra i tubi di innalzamento ......................................... :
9.5 mm
Back thermal insulation thickness / Spessore dell’isolamento termico posteriore ............... :
--
Side thermal insulation thickness / Spessore dell’isolamento termico laterale................... :
--
Insulation material / Materiale isolante
.............................................................. :
--
Casing material / Materiale di contenimento .............................................................. :
--
Sealing material / Materiale di sigillatura
.............................................................. :
--
Other limitations / Altre limitazioni
.............................................................. :
--
Report No. M1.10.SOLT.0400/40581-rev01
Page 6 of 23
Sketch of the collector / Schema del collettore
Comments on collector design / Commenti sul progetto del collettore ............................ :
Heat transfer medium / Mezzo termovettore ............................................................ :
None / Nessuno
Water – salt mixture / Soluzione
acqua e sale
Alternative acceptable heat transfer
Water (in this condition no freeze protection is ensured) / Acqua (in questa
fluids / Fluido termovettore alternative accettabile : condizione non è assicurata la protezione dal gelo)
Test item particulars: / Particolari dell’oggetto in prova
Accessories and detachable parts included in the evaluation / Accessori e parti
separabili incluse nella valutazione.................................................................................. :
--
Options included / Opzioni incluse ......................................................................... :
--
Component list / Distinta dei componenti
Item / Componente
Supplier / Fornitore
Item code / Codice
Notes-material / Note - materiale
componente
Tubi manifold / Manifold tubes
--
--
--
Tubi assorbitore / Absorber tubes
--
--
--
Report No. M1.10.SOLT.0400/40581-rev01
Page 7 of 23
Test summary statement / Attestazione di prova
The product tested as described on page 1 through 7 complies with the requirements of the
th
standard(s) mentioned on page 1, as detailed below. The measurements were carried out from 29
th
March 2010 to 30 July 2010. No problems or relevant observations occurred during the
measurements.
Il prodotto testato, come descritto nelle pagine da 1 a 9, rispetta i requisiti della(e) norma(e) citata (e) a pagina 1, come
dettagliato nel seguito. Le misure sono state effettuate dal 29 marzo 2010 al 30 luglio 2010. Durante le misure non è stato
evidenziato nessun problema né rilievo significativo.
Record of test sequence and summary of main results / Sequenza delle prove
Clause
Date / Data
Clause
EN 129751
EN 129752
5.3.2
5.2
Test / Prova
Internal pressure for absorbers /
Results
Start /
End /
Inizio
Fine
2010/05/24
2010/05/24
Pressione interna degli assorbitori
5.3.3
5.3
5.4
High temperature resistance /
2010/04/06
2010/04/06
2010/04/05
2010/05/26
Prova di esposizione
5.3.5
5.5
Prova dello shock termico
esterno
Internal thermal shock /
5.3.6
5.3.7
5.6
5.7
Prova dello shock termico
interno
5.3.8
5.8
5.9
First
2010/04/21
2010/04/21
Second
2010/05/21
2010/05/21
First
2010/04/22
2010/04/22
Second
2010/05/26
2010/05/26
2010/05/19
2010/05/19
Rain penetration test /
Freeze resistance test /
2010/03/29
2010/03/29
Prova di resistenza al gelo
Mechanical load test/
5.10
Impact resistance test (optional)/
5.11
5.3.9
6
Dismantling final inspection /
2010/07/30
2010/07/30
PASS
(see Tab. 5)
PASS
PASS
PASS
(see Tab. 8)
--
--
2010/07/30
2010/07/30
Ispezione finale di smontaggio
Thermal performance testing /
(see Tab. 4)
(see Tab. 7)
Prova di resistenza all’impatto (opzionale)
--
PASS
(see Tab. 6)
Prova di carico meccanico
4.1.7
PASS
(see Tabb. 3A, 3B)
Prova di penetrazione della pioggia
5.3.10
PASS
(see Tab. 2)
Exposure test /
External thermal shock /
PASS
(see Tab. 1)
Resistenza alle alte temperature
5.3.4
Risultati
Not performed
PASS
(see Tab. 9)
2010/03/29
2010/07/30
See/vedi tab. 10
Prova delle prestazioni termiche
Report No. M1.10.SOLT.0400/40581-rev01
Page 8 of 23
§ 5.2
TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori
inorganici
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] .................... :
--
Test installation / Installazione di prova
Outdoor
--
Indoor
Maximum allowed working pressure
-MS [kPa] / Massima pressione di esercizio
ammessa specificata dal costruttore [kPa]
Test ambient temperature [°C] /
Test conditions / Condizioni di prova
Temperatura ambiente di prova [°C]
--
Test pressure [kPa] / Pressione di prova [kPa]
--
Test duration [min] / Durata di prova [min]
--
Results / Risultati
Potential failure. / --.
Failure
occurred/
Verdict
Absorber leakage
--
Deformation such to establish permanent contact
between absorber and cover
--
Breaking or permanent deformation of collector fixing
points or collector box
--
Vacuum loss
--
Accumulation of humidity in form of condensate on the
inside of the transparent cover of the collector
exceeding 10% of the aperture area
--
Other:
--
Remarks / Osservazioni: The test is not applicable to the collector / la prova non è applicabile al collettore
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
NOT APPLICABLE
Page 9 of 23
§ 5.2
TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ............... :
Test installation / Installazione di prova
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ....................
2010/05/24
Outdoor
2010/05/24
Indoor
Method used to pressurize the absorber / Metodo usato per pressurizzare il collettore:
Pneumatic
Hydraulic
Method used to keep the absorber
warm / Metodo usato per mantenere caldo il
Solar simulator
Natural sunlight
Heated water bath
collettore:
Heated pressurized
circuit
Maximum allowed working pressure MS [kPa] / Massima pressione di esercizio specificata dal costruttore [kPa]
Test pressure
[kPa] / Pressione di
prova [kPa]
100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
420
440
460
--------
Test conditions /
Condizioni di prova
Surrounding
air
temperature
[°C] /
Absorber
temperature
[°C] /
Temperatura di
prova [°C]
Temperatura
dell’assorbitore
[°C]
29.7
29.7
29.8
29.8
29.8
29.8
29.8
29.7
29.7
29.7
29.8
29.8
29.8
29.7
29.8
29.8
29.7
29.8
29.9
--------
82
83
82
81
81
82
83
83
84
83
83
82
82
82
81
82
82
83
83
--------
Global solar
irrdiance
2
[W/m ]
Duration
[min] /durata
1015
1023
1027
1021
1018
1015
1021
1025
1028
1024
1023
1026
1019
1018
1014
1006
1019
1023
1016
--------
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
62
--------
Potential failure. / potenziale anomalia.
300
Failure occurred
[min]
Failure / Anomalia
Verdict
Vacuum loss
P
P
P
P
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
P
Other:
P
Absorber leakage
Deformation such to establish permanent contact between absorber and cover
Results / Risultati Breaking or permanent deformation of collector fixing points or collector box
Remarks / Osservazioni
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 10 of 23
§ 5.3
TAB. 2: High temperature resistance / Resistenza alle alte temperature
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................
Test installation / Installazione di
prova
Test end [YYYY/MM/DD] /
....................:
2010/04/06
2010/04/06
Data fine prova [AAAA/MM/GG]
Indoor – solar simulator
Outdoor
Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova è stata effettuata su di un
collettore a tubi evacuati
The temperature of the collector was measured at the location shown below: / La temperatura del collettore è stata misurata nella
posizione illustrata di seguito:
--
Additional information required if the absorber temperature was measured using a special fluid:
The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to
the average absorber temperature of …....….… °C
Collector tilt angle [°] /
45
Inclinazione del collettore [°]
2
Average irradiance [W/m ] / Irraggiamento medio [W/m2]
983
Test conditions / Condizioni di
Average surrounding air temperature [°C] / Temperatura ambiente media [°C]
29.4
prova
Average surrounding air speed m/s] / Velocità del vento media [m/s]
1.1
Average absorber temperature [°C] / Temperatura media dell’assorbitore [°C]
81
Test duration [min] / Durata di prova [min]
66
Calculated collector stagnation temperature [°C] /
Results /
Temperatura di stagnazione del collettore calcolata [°C]
Failure
occurred/
Potential failure. / --.
Risultati
85.5
Verdict
Absorber leakage
P
Deformation such to establish permanent contact between absorber and cover
P
Breaking or permanent deformation of collector fixing points or collector box
P
Vacuum loss
P
Accumulation of humidity in form of condensate on the inside of the transparent cover of the
collector exceeding 10% of the aperture area
P
Other:
--
Remarks / Osservazioni
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 11 of 23
§ 5.4
TAB. 3A: Exposure test / Prova di esposizione
Test start [YYYY/MM/DD] / Data inizio prova
[AAAA/MM/GG] ................................... :
2010/04/05
Test end [YYYY/MM/DD] / Data fine
2010/05/26
prova [AAAA/MM/GG] ............................... :
Collector tilt / Inclinazione del collettore [°]:
45
Collector azimuth / angolo azimutale del collettore rispetto al sud [°]:
0
Day
Date
Irradiation H
[MJ/m2]
Air temperature
ta [°C]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
2010/04/05
2010/04/06
2010/04/07
2010/04/08
2010/04/09
2010/04/10
2010/04/11
2010/04/12
2010/04/13
2010/04/14
2010/04/15
2010/04/16
2010/04/17
2010/04/18
2010/04/19
2010/04/20
2010/04/21
2010/04/22
2010/04/23
2010/04/24
2010/04/25
2010/04/26
2010/04/27
2010/04/28
2010/04/29
2010/04/30
16.3
16.5
16.4
16.1
15.2
17.1
3.4
2.2
4.6
15.7
4.6
8.3
3.7
17.2
17.3
16.4
18.1
14.7
3.1
2.6
15.1
2.1
1.8
14.5
16.8
3.4
17
18
17
16
22
24
13
12
14
17
16
18
16
14
22
23
23
21
15
20
24
24
18
23
23
21
Rain
Day
Date
Irradiation H
[MJ/m2]
Air temperature ta
[°C]
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
2010/05/01
2010/05/02
2010/05/03
2010/05/04
2010/05/05
2010/05/06
2010/05/07
2010/05/08
2010/05/09
2010/05/10
2010/05/11
2010/05/12
2010/05/13
2010/05/14
2010/05/15
2010/05/16
2010/05/17
2010/05/18
2010/05/19
2010/05/20
2010/05/21
2010/05/22
2010/05/23
2010/05/24
2010/05/25
2010/05/26
2.7
1.8
3.1
17.4
1.2
16.2
4.5
14.8
3.8
6.3
5.4
7.2
8.4
7.7
15.4
16.1
17.4
18.2
18.4
18.3
18.2
18.7
19.1
19.6
19.3
18.4
18
15
18
12
13
15
12
17
17
18
18
18
18
16
20
22
22
22
20
24
25
26
26
27
27
24
2
Date
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
2010/04/05
2010/04/06
2010/04/07
2010/04/08
2010/04/09
2010/04/10
2010/04/14
2010/04/18
2010/04/19
2010/04/20
2010/04/21
2010/04/22
2010/04/28
2010/04/29
2010/05/04
Irradiance G
[W/m2]
904
901
891
926
919
900
909
872
901
901
903
906
903
909
895
Air temperature
ta [°C]
17
18
17
16
22
24
17
14
22
23
23
21
23
23
12
2
Time periods
[min]
73
60
70
51
51
64
66
71
86
46
81
71
76
76
97
Period
Date
16
17
18
19
20
21
22
23
24
25
26
27
28
29
2010/05/06
2010/05/08
2010/05/15
2010/05/16
2010/05/17
2010/05/18
2010/05/19
2010/05/20
2010/05/21
2010/05/22
2010/05/23
2010/05/24
2010/05/25
2010/05/26
Irradiance G
[W/m2]
909
920
896
896
910
899
885
978
878
909
873
906
880
908
Air temperature ta
[°C]
15
17
20
22
22
22
20
24
25
26
26
27
27
24
Total hours with G > 850 W/m , air temperature > 10 ° C / Ore totali con G > 850 W/m2; temperatura ambiente > 10 °C :
Report No. M1.10.SOLT.0400/40581-rev01
30
Total days in which H > 14 MJ/m / Giorni totali con H > 14 MJ/m2:
Period
Rain
Time periods
[min]
54
81
37
74
63
45
63
73
89
88
59
74
80
76
33
Page 12 of 23
§ 5.4
TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione
Test start [YYYY/MM/DD]
2010/05/26
Data inizio prova [AAAA/MM/GG]
Test end [YYYY/MM/DD]
2010/05/26
Data fine prova [AAAA/MM/GG]
Collector fluid loop / Circuito idraulico del collettore
Potential problems
Evaluation*
Verdict
Swelling of pipes and components / Rigonfiamenti di tubature e componenti
0
P
Fluid leakages / Perdite di liquidi e sgocciolamenti
0
P
Cracking / Rotture
0
P
Warping / Deformazioni
0
P
Corrosion / Corrosione
0
P
Evaluation*
Verdict
0
P
0
P
0
P
0
P
Deformation/corrosion/leakage/loss of bonding of the absorber tubes and
headers / Deformazioni/corrosione/perdite/distacchi dei tubi dell’assorbitore e dei raccordi
0
P
Deformation/corrosion of the absorber mountings / Deformazioni/segni di
0
P
0
P
Strength / Solidità
0
P
Safety / Sicurezza
0
P
Loss of function / Perdita di funzionalità
N/A
N/A
Safety / Sicurezza
N/A
N/A
Collector / Collettore
Potential problems/failures
Cracking/warping/corrosion/rain penetration of the collector box/fasteners
Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli
aggraffaggi
Cracking/adhesion/elasticity of the seals/gaskets /
Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni
Cracking/crazing/buckling/delamination/ warping/outgassing of the
cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto
della copertura e/o del riflettore
Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di
bolle sul rivestimento dell’assorbitore
corrosione dei dispositivi di montaggio e fissaggio dell’assorbitore
Water retention/outgassing/degradation of the thermal insulation /
Ritenzione d’acqua/perdita di vuoto/ degradazione dell’isolante termico
Mounting structure / Strutture di montaggio
Safety equipment / Equipaggiamento di sicurezza
*Evaluation scale / Scala di valutazione:
0 - No problem / Nessun problema
1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore
2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili
N/A - Inspection to establish the condition was not possible / Ispezione non possibile
Remarks / Osservazioni
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 13 of 23
§ 5.5
TAB. 4: External thermal shock test / Prova dello shock termico esterno
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
2010/04/21
Test installation / Installazione di prova
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] .................... :
Outdoor
2010/05/21
Indoor
Test combined with exposure test / Test combinato con il test di esposizione
Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte
temperature
Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova
è stata effettuata su di un collettore a tubi evacuati
The temperature of the collector was measured at the location shown below: / La
--
temperatura del collettore è stata misurata nella posizione illustrata di seguito:
Additional information required if the absorber temperature was measured using a special
fluid:
The collector was partially filled with ………….. and the average pressure was ………….
Pa, which corresponds to the average absorber temperature of …....….… °C
Shock n°
Test conditions / Condizioni di prova
Test date / data di prova
Collector tilt angle [°] / Angolo di inclinazione del collettore [°]
2
Average irradiance [W/m ] / Irraggiamento medio [W/m2]
2
Minimum irradiance [W/m ] / Irraggiamento minimo [W/m2]
Average air temperature [°C] /
Temperatura ambiente media [°C]
Minimum air temperature [°C] / Temperatura amb. minima [°C]
Preconditioning period [min] / Durata di precondizionamento [min]
Absorber temp. before spraying [°C] / Temp. dell’assorbitore prima del getto [°C]
2
Flow rate of water spray [kg/(s·m )] / Portata del getto d’acqua [kg/(s•m2)]
Temperature of water spray [°C] / Temperatura del getto d’acqua [°C]
Duration of water spray [min] /
Durata del getto d’acqua [min]
Potential failure. / Danno potenziale
--
1
2
2010/04/21
45
927
902
23.2
22.9
61
78.2
0.031
16.5
15
2010/05/21
45
976
954
25.1
24.6
62
78.9
0.033
17.2
16
Failure occurred/ danneggiamenti occorsi
Absorber leakage
Deformation such to establish permanent contact between absorber
and cover
Breaking or permanent deformation of collector fixing points or
Results / Risultati collector box
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the
transparent cover of the collector exceeding 10% of the aperture area
Other:
Remarks / Osservazioni :
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 14 of 23
§ 5.6
TAB. 5: Internal thermal shock test / Prova dello shock termico interno
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
2010/04/22
Test installation / Installazione di prova
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] .................... :
Outdoor
2010/05/26
Indoor
Test combined with exposure test / Test combinato con il test di esposizione
Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte
temperature
Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova
è stata effettuata su di un collettore a tubi evacuati
The temperature of the collector was measured at the location shown below: / La
--
temperatura del collettore è stata misurata nella posizione illustrata di seguito:
Additional information required if the absorber temperature was measured using a special
fluid:
The collector was partially filled with ………….. and the average pressure was ………….
Pa, which corresponds to the average absorber temperature of …....….… °C
Shock n°
1
2
2010/04/22
2010/05/26
45
45
946
949
Minimum irradiance W/m ] / Irraggiamento minimo [W/m ]
911
934
Average air temperature [°C] /
Temperatura ambiente media [°C]
21.2
24.8
Minimum air temperature [°C] /
Temperatura amb. minima [°C]
20.8
24.4
Preconditioning period [min] / Durata di precondizionamento [min]
62
64
Absorber temp. before flowing [°C] /
77
78
Flow rate of heat transfer fluid [kg/(s·m )] / Portata di fluido
0.022
0.023
Temperature of heat transfer fluid [°C] /
17.2
17.9
7
6
Test date / data di prova
Collector tilt angle [°] /
Angolo di inclinazione del collettore [°]
2
Average irradiance W/m ] / Irraggiamento medio [W/m2]
2
Test conditions /
Condizioni di prova
--
2
Temp. dell’assorbitore
prima del flusso [°C]
2
termovettore [kg/(s•m2)]
Temperatura del fluido
termovettore [°C]
Duration of flow [min] / Durata del flusso [min]
Potential failure. / Danno potenziale
Failure occurred/ danneggiamenti occorsi
Absorber leakage
Deformation such to establish permanent contact between absorber
and cover
Breaking or permanent deformation of collector fixing points or
Results / Risultati collector box
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the
transparent cover of the collector exceeding 10% of the aperture area
Other:
Remarks / Osservazioni :
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 15 of 23
§ 5.7
TAB. 6: Rain penetration test / Prova di penetrazione della pioggia
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
2010/05/19
Test installation / Installazione di prova
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ....................:
Outdoor
Collector mounted on / Collettore
Indoor
Simulated roof / Tetto simulato
Open frame/ Struttura aperta
montato su:
Method used to keep the absorber
warm / Metodo usato per mantenere caldo il
collettore:
2010/05/19
Hot water circulation / Circolazione di acqua calda
Exposure of collector to solar radiation / Esposizione del
collettore alla radiazione solare
Collector tilt angle [°] /
45
Angolo di inclinazione del collettore [°]
2
Water flow rate [kg/(s·m )] / Portata di fluido termovettore [kg/(s•m2)]
0.053
Temperature of heat transfer fluid [°C] /
54.2
Test conditions /
Condizioni di prova
Temperatura del fluido termovettore [°C]
Duration of water spray [h] / Durata del getto d’acqua [h]
4
Potential failure. / Danno potenziale
Failure occurred/ danneggiamenti occorsi
Water penetration
Absorber leakage
Deformation such to establish permanent contact between absorber
and cover
Results / Risultati Breaking or permanent deformation of collector fixing points or
collector box
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the
transparent cover of the collector exceeding 10% of the aperture area
Other:
Remarks / Osservazioni :
No rain penetration / nessuna penetrazione di pioggia
No failure detected / Nessun danneggiamento rilevato
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 16 of 23
§ 5.8
TAB. 7: Freeze resistance test / Prova di resistenza al gelo
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
Collector type / Tipo di collettore
2010/03/29
Test end [YYYY/MM/DD] /
2010/03/29
:
Data fine prova [AAAA/MM/GG]
Freeze-resistant when filled with water
Drain-down
Antifreeze fluid (MS) / Liquido antigelo
specificato dal costruttore
Water- Propylene glycol mixture / Miscela acqua-glicole propilenico
Tilt angle of the collector [°] /
Test conditions / Condizioni di prova
N° of freezethaw cycle
--
Angolo di inclinazione del collettore [°]
Rate of chamber cooling [K/h] / Velocità di raffreddamento [K/h]
--
Rate of chamber heating [K/h] / Velocità di riscaldamento [K/h]
--
Freeze conditions / Condizioni di congelamento
Thaw conditions
/ Condizioni di scongelamento
Test temperature [°C]
Duration [min]
Test temperature [°C]
Duration [min]
1
--
--
--
--
2
--
--
--
--
3
--
--
--
--
Potential failure / Potenziale danneggiamento
Results /
Risultati
Failure
occurred/
Verdict
Absorber leakage
--
Deformation such to establish permanent contact between absorber and cover
--
Breaking or permanent deformation of collector fixing points or collector box
--
Vacuum loss
--
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
--
Other:
--
Remarks / Osservazioni:
The manufacturer recommends the use of a water-sodium chloride mixture in the solar loop. /
Il costruttore raccomanda l’utilizzo di una miscela acqua-cloruro di sodio nel circuito solare.
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS (see Remarks)
Page 17 of 23
§ 5.9
TAB. 8: Mechanical load test / Prova di carico meccanico
POSITIVE PRESSURE TEST OF THE COLLECTOR COVER
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
2010/07/30
Test end [YYYY/MM/DD] /
:
Data fine prova [AAAA/MM/GG]
2010/07/30
Loading with gravel or similar material
Method used to apply positive
Loading with water
pressure to the cover / Metodo usato per
Suction cups
applicare il carico positivo alla copertura
Pressurisation of collector cover
Test conditions / Condizioni di prova
1000
Maximum pressure load [Pa] / Pressione di carico massima [Pa]
Remarks / Note
Negative pressure test of fixings between the cover and collector box
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
Test end [YYYY/MM/DD] /
--
:
Data fine prova [AAAA/MM/GG]
--
Method used to apply negative
Suction cups
pressure to the cover / Metodo usato per
applicare il carico negativo alla copertura
Pressurisation of collector box
N/A
Test conditions / Condizioni di prova
Maximum pressure load [Pa] / Pressione di carico massima [Pa]
Remarks / Note
This test is not applicable to the E.u.T. / Questa prova non è applicabile al collettore
Negative pressure test of collector mountings
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................ :
Test end [YYYY/MM/DD] /
--
:
Data fine prova [AAAA/MM/GG]
--
Method used to apply negative
Suction cups
pressure to the cover / Metodo usato per
applicare il carico negativo alla copertura
Air bags
N/A
Test conditions / Condizioni di prova
Maximum pressure load [Pa] / Pressione di carico massima [Pa]
Remarks / Note
This test is not applicable to the E.u.T. / Questa prova non è applicabile al collettore
Results / Risultati
Failure
occurred/
Potential failure. / --.
Verdict
Absorber leakage
--
Deformation such to establish permanent contact
between absorber and cover
--
Breaking or permanent deformation of collector fixing
points or collector box
--
Vacuum loss
--
Other:
--
Remarks / Osservazioni:
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 18 of 23
§ 5.11
TAB. 9: Final inspection / Ispezione finale
Test start [YYYY/MM/DD]
2010/07/30
Data inizio prova [AAAA/MM/GG]
Test end [YYYY/MM/DD]
2010/07/30
Data fine prova [AAAA/MM/GG]
Collector loop pipes / Tubazioni del circuito collettore
Potential problems
Evaluation*
Verdict
Swelling of pipes and components / Rigonfiamenti di tubature e componenti
0
P
Fluid leakages / Perdite di liquidi e sgocciolamenti
0
P
Cracking / Rotture
0
P
Warping / Deformazioni
0
P
Corrosion / Corrosione
0
P
N/A
N/A
Evaluation*
Verdict
0
P
0
P
0
P
0
P
Deformation/corrosion/leakage/loss of bonding of the absorber tubes and
headers / Deformazioni/corrosion/perdite/distacchi dei tubi dell’assorbitore e dei raccordi
1
P
Deformation/corrosion of the absorber mountings / Deformazioni/segni di corrosion
0
P
0
P
Strength / Solidità
0
P
Safety / Sicurezza
0
P
Loss of function / Perdita di funzionalità
N/A
N/A
Safety / Sicurezza
N/A
N/A
Water retention/outgassing/degradation of the insulation / Ritenzione d’acqua /
Perdita del vuoto / degradazione dell’isolamento
Collector / Collettore
Potential problems/failures
Cracking/warping/corrosion/rain penetration of the collector box/fasteners
Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli
aggraffaggi
Cracking/adhesion/elasticity of the seals/gaskets /
Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni
Cracking/crazing/buckling/delamination/ warping/outgassing of the
cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto
della copertura e/o del riflettore
Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di
bolle sul rivestimento dell’assorbitore
dei dispositive di montaggio e fissaggio dell’assorbitore
Water retention/outgassing/degradation of the thermal insulation / Ritenzione
d’acqua/perdita di vuoto/ degradazione dell’isolante termico
Mounting structure / Strutture di montaggio
Safety equipment / Equipaggiamento di sicurezza
*Evaluation scale / Scala di valutazione:
0 - No problem / Nessun problema
1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore
2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili
N/A - Inspection to establish the condition was not possible / Ispezione non possibile
Remarks / Osservazioni:
Some negligible water leakage from risers near the manifold / alcune perdite trascurabile dai canali di innalzamento in
prossimità del tubo collettore
Verdict / Esito
Report No. M1.10.SOLT.0400/40581-rev01
PASS
Page 19 of 23
§6
TAB. 10: Thermal performance / Prestazioni termiche
Test start [YYYY/MM/DD]
2010/03/29
Data inizio prova [AAAA/MM/GG]
Test method / Metodo di prova
Test end [YYYY/MM/DD]
2010/07/30
Data fine prova [AAAA/MM/GG]
6.2 Outdoor – Steady state
6.2 Indoor – Steady state method
44° 52’ N
Longitude / Longitudine:
Latitude / Latitudine:
Collector tilt / Inclinazione del collettore [°]
6.3 Outdoor – quasi-dynamic
08° 48’ E
Collector azimuth
/Orientamento azimutale del
45
South / Sud
collettore
Orientation of absorber tubes during testing / Orientamento dei tubi del collettore durante la prova
Vertical/ verticale
Flow rate used for performance testing (average) / Flusso utilizzato per il test (valore medio) [kg/s]:
0.043
Test results / Risultati di prova
Condizioni ambientali m isurate
DATA POINTS
Tamb
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Net Irradiance
Global irradiance
G"
G [W/m 2]
[W/m2]
(T a)
[°C]
W ind
speed
[m/s]
28,0
0,84
966,0
28,0
28,3
0,61
0,86
959,0
968,0
28,3
0,48
28,7
Grandezze derivate
Grandezze collettore misurate
Reduced temp.
difference
Actual u seful
power [W]
Istantaneous
efficiency
(APERTURE)
Istantan eous
efficiency
(ABSORBER)
0,26
0,00035
1591,54
0,95
0,97
0,16
0,00021
1591,66
0,94
0,95
4,1786
5,36
0,00698
1507,07
0,89
0,91
33,64
4,1786
5,34
0,00673
1506,81
0,86
0,88
3,78
40,29
4,1793
11,59
0,01502
1389,83
0,82
0,83
5,28
3,78
40,29
4,1793
11,59
0,01562
1390,25
0,85
0,87
29,38
5,28
4,08
27,34
4,1791
1,34
0,00177
1499,39
0,90
0,92
25,40
29,46
5,30
4,06
27,43
4,1791
1,33
0,00179
1498,48
0,92
0,94
743,2
30,40
34,25
5,28
3,85
32,32
4,1786
5,92
0,00797
1414,50
0,87
0,88
948,4
792,1
30,40
34,25
5,28
3,85
32,32
4,1786
5,82
0,00735
1414,50
0,81
0,83
1,72
946,3
763,3
36,40
39,83
5,27
3,43
38,11
4,1790
12,01
0,01574
1258,24
0,75
0,76
25,9
1,65
935,5
766,1
36,40
39,85
5,27
3,45
38,13
4,1790
12,22
0,01595
1266,64
0,75
0,77
27,8
2,82
925,9
758,5
26,10
30,12
5,28
4,02
28,11
4,1789
0,31
0,00041
1479,09
0,89
0,90
27,7
2,97
927,6
740,9
26,00
30,01
5,30
4,01
28,01
4,1790
0,31
0,00041
1481,88
0,91
0,93
27,6
2,79
923,8
762,1
31,80
35,07
5,29
3,27
33,43
4,1786
5,83
0,00766
1204,13
0,72
0,73
27,6
2,60
926,0
732,1
31,80
35,11
5,28
3,31
33,45
4,1786
5,85
0,00799
1214,97
0,75
0,77
27,9
27,8
3,01
2,69
935,7
930,6
751,4
745,7
38,00
38,00
40,72
40,69
5,30
5,28
2,72
39,36
4,1791
11,46
0,01525
1002,91
0,61
0,62
2,69
39,35
4,1791
11,55
0,01548
989,66
0,60
0,61
Tin [°C]
Tout [°C]
Flow-Rate
[l/min]
DeltaT [K]
Mea n fluid temp.
T m [°C]
cf
758,2
26,10
30,43
5,28
4,33
28,26
4,1789
773,1
767,6
26,00
31,60
30,32
35,71
5,28
5,26
4,32
28,16
4,1789
4,11
33,66
963,5
794,4
31,60
35,69
5,29
4,09
0,75
964,0
771,5
38,40
42,18
5,28
28,7
0,78
941,0
742,2
38,40
42,18
26,0
1,52
947,6
756,3
25,30
26,1
1,56
943,8
741,9
26,4
1,42
946,5
26,5
1,47
26,1
2
Tm-Ta
[K]
2
Peak power for G” = 1000 W/m and u = 0 m/s / Potenza di picco per G” = 1000 W/m
Tm – Ta = 2 K
e u = 0m/s
[W]
2038
POWER OUTPUT per collector unit / Potenza resa per unità di collettore
Net irradiance G”
G” = 400 W /m
2
G” = 700 W /m
2
G” = 1000 W /m
u = 0.0 m/s
784
1408
2038
u = 1.0 m/s
745
1356
1974
u = 1.5 m/s
726
1329
1942
u = 2.0 m/s
706
1303
1910
u = 2.5 m/s
687
1277
1878
u = 3.0 m/s
667
1251
1846
u = 3.5 m/s
648
1224
1814
2
Remarks / Osservazioni:
Report No. M1.10.SOLT.0400/40581-rev01
Page 20 of 23
§6
TAB. 10: Thermal performance / Prestazioni termiche
2
Diagram of power output for windspeed u < 1m/s and G” = 1000 W/m /
Grafico per velocità del vento < 1 m/s e G” = 1000 W/m2
2500
Power-0m/s
2000
Power-1m/s
1500
1000
500
0
0
10
20
30
40
50
60
70
80
90
100
2
Diagram of power output for windspeed u = 1.5 ± 0.5 m/s and G” = 1000 W/m /
Grafico per velocità del vento = 1.5 ± 0.5 m/s e G” = 1000 W/m2
2500.00
Power-1m/s
2000.00
Power-1.5m/s
Power-2m/s
1500.00
1000.00
500.00
0.00
0
10
20
30
40
50
60
70
80
90
100
2
Diagram of power output for windspeed u = 3 ± 0.5 m/s and G” = 1000 W/m /
Grafico per velocità del vento = 3 ± 0.5 m/s e G” = 1000 W/m2
2500.00
Power-2.5m/s
2000.00
Power-3m/s
Power-3.5m/s
1500.00
1000.00
500.00
0.00
0
10
20
Report No. M1.10.SOLT.0400/40581-rev01
30
40
50
60
70
80
90
100
Page 21 of 23
§6
TAB. 10: Thermal performance / Prestazioni termiche
2
Efficiency curve for G” = 800 W/m and windspeed u= 1.5 m/s / - Reference area APERTURE
Curva di efficienza per G” = 800 W/m2 – Velocità del vento u = 0 m/s /, u= 1.5 m/s and u = 3 m/s
1.0
u=0 m/s
0.9
u=1.5 m/s
0.8
u=3 m/s
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.1
Parameters for efficiency equation / Parametri dell’equazione di efficienza
Parameter
Absorber area
Aperture area
Gross area
η0
[]
0.95
0.93
0.89
b1
[W/m K]
6.55
6.43
6.15
b2
[W/m K ]
4.03
3.96
3.78
bu
[]
0.02
0.02
0.02
2
2
2
Remarks / Osservazioni:
Report No. M1.10.SOLT.0400/40581-rev01
Page 22 of 23
§6
TAB. 10: Thermal performance / Prestazioni termiche
0.99
Incidence Angle Modifier (IAM) at 50° / Fattore di angolo di incidenza a 50°............... ........................... [ ]
50°
°
0°
10°
20°
30°
40°
60°
70°
80°
90°
Kθ longitudinal - IAML
1
1
1
1
1
0.99
0.97
0.92
0.66
0.00
Kθ transversal IAMT
1
1
1
1
1
0.99
0.97
0.92
0.66
0.00
IAMT
IAML
1.2
1
0.8
0.6
0.4
0.2
0
0
20
40
60
80
Remarks / Osservazioni:
Time constant τc / Costante di tempo
.................................................................................................................... [s]
143
Remarks / Osservazioni:
The time constant τc of the collector has been measured as the time elapsed between the removal of a cover used to
achieve a steady state condition of the water temperature at the outlet and the point where the collector outlet
temperature rises to 63,2 % of the total increase up to the next steady state condition.
La costante di tempo τc del collettore è stata misurata come il tempo trascorso tra la rimozione del rivestimento usato per raggiungere la condizione
stazionaria della temperatura dell’acqua all’uscita e al punto dove la temperatura di uscita del collettore sale a 63,2% dell’incremento totale alla
successiva condizione stazionaria.
Effetcive thermal capacity / Capacità termica effettiva ...................................................................................... [kJ/K]
33.6
Remarks / Osservazioni:
La capacità termica effettiva è calcolata dalle registrazioni misurate di tin, ∆Τ, ta, G utilizzando la seguente relazione per
test all’aperto:
The effective thermal capacity is calculated from or from the measurement records of tin, ∆Τ, ta , G and by the following relation for outdoor testing :
----------------- End of Test Report No. M1.10.SOLT.0400/40581-rev01 -----------------Report No. M1.10.SOLT.0400/40581-rev01