10156 TORINO (ITALY) – 21, Via Cuorgnè Tel. +39.011.22.22.225 – Fax +39.011.22.22.226 – e-mail: [email protected] – web: www.eurofins.com TEST REPORT EN 12975-2: 2006: Thermal solar systems and components - Solar collectors – Part2: Test methods Impianti solari termici e loro componenti - Collettori solari - Parte 2: Metodi di prova Report Reference No./ Numero rapporto ..: M1.10.SOLT.0400/40581-rev01 Date of issue / Data di emissione ................: 2010-08-06 Total number of pages / N° tot. di pagine.... : 23 Testing Laboratory / Laboratorio di prova ..: Eurofins – Modulo Uno S.p.A. Address / Indirizzo ..................................: Strada Savonesa, 9 - 15050 Rivalta Scrivia (AL) – Italy Applicant’s name / Nome del richiedente ...: Janus Energy S.r.l. Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy Address / Indirizzo ..................................: Test specification / Specifiche di prova Standard / Norma ...................................: Non-standard test method ..................: EN 12975-2:2006 N/A Metodo di prova non standard Scope of the test / Scopo della prova To determine the steady-state and quasi-dynamic thermal performance of glazed and unglazed liquid heating solar collectors, within the scope of EN 12975-1:2006 “Thermal solar systems and components – Solar collectors - Part 1: General requirements”. Caratterizzazione delle prestazioni termiche in condizioni stazionarie e quasi dinamiche, nello scopo della norma EN 12975-1: 2006: Sistemi e componenti solari termici – Collettori solari – Parte 1: Requisiti generali”. Test item description ........................: Unglazed liquid heating solar collector. Descrizione dell’oggetto in prova Collettore solare non vetrato per il riscaldamento di liquidi Trade Mark .........................................: Marchio Manufacturer / Costruttore..................: Janus Energy S.r.l. Address / Indirizzo ..................................: Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy Model/Type reference / Modello .............: SUNNYDAY – SF2000 Date of receipt of the test item............: 2010/03/17 Data di ricevimento dell’oggetto in prova Testing period / Periodo di prova ................: 2010/03/29 ÷ 2010/07/30 This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory The test results presented in this report relate only to the object tested. Eurofins Modulo Uno S.p.A. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia. I risultati esposti in questo rapporto di prova si riferiscono esclusivamente all’oggetto testato. Eurofins Modulo Uno S.p.A. non assume alcuna responsabilità per danni derivanti dall’interpretazione del lettore del materiale riprodotto al di fuori del suo contesto. This Test Report cancel and replace the previous review / Il presente Rapporto di Prova annulla e sostituisce la revisione precedente 01 P.Ind. Bruno Vaisitti Ing. Giovanni Bellenda Revision n° Test responsible Head of thermal solar testing dept. 0 P.Ind. Bruno Vaisitti Ing. Giovanni Bellenda Revision n° Test responsible Head of thermal solar testing dept. Summary / Sommario GENERAL INFORMATION / INFORMAZIONI GENERALI ______________________________3 Description of test item construction / Descrizione della costruzione dell’oggetto in prova 4 Test summary statement / Attestazione di prova__________________________________8 Record of test sequence and summary of main results / Sequenza delle prove ___________8 TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici __________________________________________________________________________9 TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici10 TAB. 2: High temperature resistance / Resistenza alle alte temperature _______________11 TAB. 3A: Exposure test / Prova di esposizione ____________________________________12 TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione __________13 TAB. 4: External thermal shock test / Prova dello shock termico esterno _______________14 TAB. 5: Internal thermal shock test / Prova dello shock termico interno ________________15 TAB. 6: Rain penetration test / Prova di penetrazione della pioggia ___________________16 TAB. 7: Freeze resistance test / Prova di resistenza al gelo __________________________17 TAB. 8: Mechanical load test / Prova di carico meccanico ___________________________18 TAB. 9: Final inspection / Ispezione finale _______________________________________19 TAB. 10: Thermal performance / Prestazioni termiche______________________________20 Test results / Risultati di prova ________________________________________________20 POWER OUTPUT per collector unit / Potenza resa per unità di collettore ______________20 Incidence Angle Modifier (IAM) at 50° / Fattore di angolo di incidenza a 50° ____________23 Time constant τc / Costante di tempo [s]_______________________________________23 Effetcive thermal capacity / Capacità termica effettiva Report No. M1.10.SOLT.0400/40581-rev01 [kJ/K] ______________________23 Page 2 of 23 GENERAL INFORMATION / INFORMAZIONI GENERALI General remarks / Note generali: • This publication may be reproduced in whole or in part for non-commercial purposes as long as Eurofins Modulo Uno S.p.A. is acknowledged as copyright owner and source of the material and only with the written permission. Questa pubblicazione può essere riprodotta per intero o parzialmente per scopi non commerciali a condizione che Eurofins Modulo Uno S.p.A. sia riconoscibile come proprietaria dei diritti d’autore e fonte del materiale e solo con autorizzazione scritta. • The test results presented in this report relate only to the object tested. I risultati esposti in questo rapporto di prova si riferiscono esclusivamente all’oggetto testato. • This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia. • "(see annex #)" refers to additional information included in the report. “(vedi allegato #)” è un riferimento ad informazioni aggiuntive incluse al rapporto • "(see tab. #)" refers to a table included in the report. “(vedi tab.#)” è un riferimento ad una tabella inclusa al rapporto • Throughout this report a comma (point) is used as the decimal separator. In questo rapporto di prova il punto è utilizzato come separatore decimale Testing location(s): Eurofins - Modulo Uno S.p.A. Sito(i) di prova Strada Comunale Savonesa, 9 15050 Rivalta Scrivia (AL) – Italy Latitude / Latitudine: 44° 52’ N Longitude / Longitudine: 08° 48’ E Tel. +39 011 2222225 Fax +39 011 2222226 e-mail: [email protected] web: www.product-testing.eurofins.com Tests performed (name of test and test clause) ........................ : EN 12975-2 Prove eseguite (nome ed articolo del test) Possible test case verdicts / Esiti di prova possibili: - test case does not apply to the test object / il requisito non è applicabile all’oggetto in prova ..........: N/A - test object does meet the requirement / l’oggetto in prova rispetta il requisito ..............................: Pass (P) - test object does not meet the requirement / l’oggetto in prova non rispetta il requisito ...................: Fail (F) Abbreviations used in this report / Abbreviazioni usate in questo rapporto: Manufacturer’s Specification / Specifica fornita dal costruttore ......................................................: MS Equipment under Test / Oggetto in prova...................................................................................: E.u.T. Meteo parameters Ambient or surrounding air temperature [°C] ........ ................................................................: -2 Ta or ta Global hemispherical solar irradiance [Wm ] .......................................................................: G* Wind speed [m/s]...................................................................................................................: u Definition of efficiency Thermal output power of collector ................................................................................ [W] : 2 A 2 G” Reference area ............................................................................................................. [m ] : Net irradiance .......................................................................................................... [W/m ] : Report No. M1.10.SOLT.0400/40581-rev01 Page 3 of 23 Description of test item construction / Descrizione della costruzione dell’oggetto in prova Orderer / Richiedente ............................. : Janus Energy S.r.l. Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy Expeller / Rivenditore ............................. : Janus Energy S.r.l. Manufacturer / Costruttore ..................... : Janus Energy S.r.l. Sampling procedure / Procedura di campionamento........................................ : produzione Random sampling from production / Campionamento casuale dalla Prototype submitted by client / Prototipo fornito dal cliente Brand name / Nome commerciale ............ : SUNNYDAY – SF2000 Serial number / Numero di serie .............. : -- Lab. Identification code / Codice identificativo del laboratorio ......................... : 10.0547 Picture of marking plate / Immagine dell’etichetta: Photograph(s) of the E.u.T. / Foto dell’oggetto in prova Report No. M1.10.SOLT.0400/40581-rev01 Page 4 of 23 Ratings / Dati tecnici nominali Max working temperature [°C] / Massima temperatura operativa [°C] ............................ : Max working pressure [bar] / Massima pressione operativa [bar] .................................. : 2 Rated (recommended) flow rate [l/m h] / Portata nominale (consigliata) [l/m h] ............. : 2 93 3 50 Collector / Collettore Manufacturer / Costruttore ............................: Janus Energy S.r.l. Via S. Filippo, 2 - 60044 Fabriano (AN) - Italy Model / Modello ...........................................: SUNNYDAY – SD 2000F Glazed flat plate / Vetrato piano Vacuum tube – Heat pipe single glass tube / Tubi evacuati – Tubo di calore singola copertura vetrata Vacuum tube – Heat pipe double glass tube / Tubo di calore doppia copertura vetrata Collector type / Tipo di collettore ................: Vacuum tube – U Tube / Tubi evacuati – Tubi a U Vacuum tube – filled with water / Tubi evacuati riempiti d’acqua Without covering – unglazed / Scoperto - non vetrato Other / Altro Serial product / Prodotto di serie ............................................................................. : YES / SÌ Drawing number / N° di disegno ............................................................................ : -- Serial number / Numero di serie ............................................................................. : -- Date when manufactured / data di costruzione ........................................................ -- Collector loop flow range [kg/s] / Campo di flusso del circuito collettore [kg/s] ................... : -- Operating pressure [kPa] / Pressione di esercizio ..................................................... : < 300 NO 2 Stagnation temperature at 1000 W/m and 30°C ambient temperature [°C] / Temperatura di stagnazione a 1000 W/m2 e 30°C di te mperature ambiente [°C] ................................ : Collector mounting / Montaggio del collettore ............................................................ : Support metal frame material (if any) Materiale del supporto metallico N° of collectors / N° di collettori (se esistente) ........ : ............................................................................. : -on plastic support / Polymeric 3 Gross length [mm] / Lunghezza lorda [mm] ............................................................... : 2040 Gross width [mm] / Larghezza lorda [mm] ................................................................. : 353 x 3 = 1059 Gross height [mm] / Altezza lorda [mm] ................................................................... : 5 2 Gross area [m ] / Superficie lorda [m2] ..................................................................... : 2 Aperture area [m ] / Superficie di apertura [m2] ........................................................... : 2 2.2 2.16 Absorber area [m ] / Superficie assorbitore [m2].......................................................... : 1.86 Weight empty [kg] / Peso a vuoto [kg] ..................................................................... : 1.7 x 3 = 5.1 Weight without glazing [kg] / Peso senza copertura vetrata [kg]..................................... : -- Fluid capacity [l] / Capacità di contenimento di fluido [l] ................................................... : 2.37 x 3 = 7.1 Report No. M1.10.SOLT.0400/40581-rev01 su supporto plastico Page 5 of 23 Number of covers / Numero di coperture 0 Cover material / Materiale copertura -- Cover thickness [mm] / Spessore copertura [mm] -- Cover solar transmittance [%] / Trasmittanza solare della copertura [%] .......................... : -- Absorber material / Materiale assorbitore : Polypropylene / Polipropilene Absorber’s dimensions / Dimensioni dell’assorbitore ................................................... : 310 x 2000 x 3 Absorber’s thickness [mm] / Spessore dell’assorbitore [mm] ........................................ 3 Absorber dry weight [kg] / Peso a vuoto dell’assorbitore [kg] ......................................... : -- Absorber – Fin width [mm] / Larghezza alette dell’assorbitore [mm] ................................ : -- Absorber – Fin thickness [mm] / Spessore alette dell’assorbitore [mm] ........................... : -- Solar absorptance α / Fattore di assorbimento solare α ............................................... : -- Hemispherical emittance ε / Emittanza emisferica ε .................................................. : -- Surface treatment / Trattamento superficiale.............................................................. : -- Construction type / Tipo di costruzione Unglazed – Extruded Polypropylene / Scoperto – .............................................................. : Polipropilene estruso Number of risers / Numero di tubi di innalzamento ........................................................ : 3 x 37 = 111 Riser diameter or dimensions / Dimensioni o diametro dei tubi di innalzamento .................. : -- Distance between risers / Distanza tra i tubi di innalzamento ......................................... : 9.5 mm Back thermal insulation thickness / Spessore dell’isolamento termico posteriore ............... : -- Side thermal insulation thickness / Spessore dell’isolamento termico laterale................... : -- Insulation material / Materiale isolante .............................................................. : -- Casing material / Materiale di contenimento .............................................................. : -- Sealing material / Materiale di sigillatura .............................................................. : -- Other limitations / Altre limitazioni .............................................................. : -- Report No. M1.10.SOLT.0400/40581-rev01 Page 6 of 23 Sketch of the collector / Schema del collettore Comments on collector design / Commenti sul progetto del collettore ............................ : Heat transfer medium / Mezzo termovettore ............................................................ : None / Nessuno Water – salt mixture / Soluzione acqua e sale Alternative acceptable heat transfer Water (in this condition no freeze protection is ensured) / Acqua (in questa fluids / Fluido termovettore alternative accettabile : condizione non è assicurata la protezione dal gelo) Test item particulars: / Particolari dell’oggetto in prova Accessories and detachable parts included in the evaluation / Accessori e parti separabili incluse nella valutazione.................................................................................. : -- Options included / Opzioni incluse ......................................................................... : -- Component list / Distinta dei componenti Item / Componente Supplier / Fornitore Item code / Codice Notes-material / Note - materiale componente Tubi manifold / Manifold tubes -- -- -- Tubi assorbitore / Absorber tubes -- -- -- Report No. M1.10.SOLT.0400/40581-rev01 Page 7 of 23 Test summary statement / Attestazione di prova The product tested as described on page 1 through 7 complies with the requirements of the th standard(s) mentioned on page 1, as detailed below. The measurements were carried out from 29 th March 2010 to 30 July 2010. No problems or relevant observations occurred during the measurements. Il prodotto testato, come descritto nelle pagine da 1 a 9, rispetta i requisiti della(e) norma(e) citata (e) a pagina 1, come dettagliato nel seguito. Le misure sono state effettuate dal 29 marzo 2010 al 30 luglio 2010. Durante le misure non è stato evidenziato nessun problema né rilievo significativo. Record of test sequence and summary of main results / Sequenza delle prove Clause Date / Data Clause EN 129751 EN 129752 5.3.2 5.2 Test / Prova Internal pressure for absorbers / Results Start / End / Inizio Fine 2010/05/24 2010/05/24 Pressione interna degli assorbitori 5.3.3 5.3 5.4 High temperature resistance / 2010/04/06 2010/04/06 2010/04/05 2010/05/26 Prova di esposizione 5.3.5 5.5 Prova dello shock termico esterno Internal thermal shock / 5.3.6 5.3.7 5.6 5.7 Prova dello shock termico interno 5.3.8 5.8 5.9 First 2010/04/21 2010/04/21 Second 2010/05/21 2010/05/21 First 2010/04/22 2010/04/22 Second 2010/05/26 2010/05/26 2010/05/19 2010/05/19 Rain penetration test / Freeze resistance test / 2010/03/29 2010/03/29 Prova di resistenza al gelo Mechanical load test/ 5.10 Impact resistance test (optional)/ 5.11 5.3.9 6 Dismantling final inspection / 2010/07/30 2010/07/30 PASS (see Tab. 5) PASS PASS PASS (see Tab. 8) -- -- 2010/07/30 2010/07/30 Ispezione finale di smontaggio Thermal performance testing / (see Tab. 4) (see Tab. 7) Prova di resistenza all’impatto (opzionale) -- PASS (see Tab. 6) Prova di carico meccanico 4.1.7 PASS (see Tabb. 3A, 3B) Prova di penetrazione della pioggia 5.3.10 PASS (see Tab. 2) Exposure test / External thermal shock / PASS (see Tab. 1) Resistenza alle alte temperature 5.3.4 Risultati Not performed PASS (see Tab. 9) 2010/03/29 2010/07/30 See/vedi tab. 10 Prova delle prestazioni termiche Report No. M1.10.SOLT.0400/40581-rev01 Page 8 of 23 § 5.2 TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... : -- Test installation / Installazione di prova Outdoor -- Indoor Maximum allowed working pressure -MS [kPa] / Massima pressione di esercizio ammessa specificata dal costruttore [kPa] Test ambient temperature [°C] / Test conditions / Condizioni di prova Temperatura ambiente di prova [°C] -- Test pressure [kPa] / Pressione di prova [kPa] -- Test duration [min] / Durata di prova [min] -- Results / Risultati Potential failure. / --. Failure occurred/ Verdict Absorber leakage -- Deformation such to establish permanent contact between absorber and cover -- Breaking or permanent deformation of collector fixing points or collector box -- Vacuum loss -- Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area -- Other: -- Remarks / Osservazioni: The test is not applicable to the collector / la prova non è applicabile al collettore Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 NOT APPLICABLE Page 9 of 23 § 5.2 TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ............... : Test installation / Installazione di prova Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... 2010/05/24 Outdoor 2010/05/24 Indoor Method used to pressurize the absorber / Metodo usato per pressurizzare il collettore: Pneumatic Hydraulic Method used to keep the absorber warm / Metodo usato per mantenere caldo il Solar simulator Natural sunlight Heated water bath collettore: Heated pressurized circuit Maximum allowed working pressure MS [kPa] / Massima pressione di esercizio specificata dal costruttore [kPa] Test pressure [kPa] / Pressione di prova [kPa] 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 -------- Test conditions / Condizioni di prova Surrounding air temperature [°C] / Absorber temperature [°C] / Temperatura di prova [°C] Temperatura dell’assorbitore [°C] 29.7 29.7 29.8 29.8 29.8 29.8 29.8 29.7 29.7 29.7 29.8 29.8 29.8 29.7 29.8 29.8 29.7 29.8 29.9 -------- 82 83 82 81 81 82 83 83 84 83 83 82 82 82 81 82 82 83 83 -------- Global solar irrdiance 2 [W/m ] Duration [min] /durata 1015 1023 1027 1021 1018 1015 1021 1025 1028 1024 1023 1026 1019 1018 1014 1006 1019 1023 1016 -------- 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 62 -------- Potential failure. / potenziale anomalia. 300 Failure occurred [min] Failure / Anomalia Verdict Vacuum loss P P P P Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area P Other: P Absorber leakage Deformation such to establish permanent contact between absorber and cover Results / Risultati Breaking or permanent deformation of collector fixing points or collector box Remarks / Osservazioni Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 10 of 23 § 5.3 TAB. 2: High temperature resistance / Resistenza alle alte temperature Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ Test installation / Installazione di prova Test end [YYYY/MM/DD] / ....................: 2010/04/06 2010/04/06 Data fine prova [AAAA/MM/GG] Indoor – solar simulator Outdoor Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova è stata effettuata su di un collettore a tubi evacuati The temperature of the collector was measured at the location shown below: / La temperatura del collettore è stata misurata nella posizione illustrata di seguito: -- Additional information required if the absorber temperature was measured using a special fluid: The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to the average absorber temperature of …....….… °C Collector tilt angle [°] / 45 Inclinazione del collettore [°] 2 Average irradiance [W/m ] / Irraggiamento medio [W/m2] 983 Test conditions / Condizioni di Average surrounding air temperature [°C] / Temperatura ambiente media [°C] 29.4 prova Average surrounding air speed m/s] / Velocità del vento media [m/s] 1.1 Average absorber temperature [°C] / Temperatura media dell’assorbitore [°C] 81 Test duration [min] / Durata di prova [min] 66 Calculated collector stagnation temperature [°C] / Results / Temperatura di stagnazione del collettore calcolata [°C] Failure occurred/ Potential failure. / --. Risultati 85.5 Verdict Absorber leakage P Deformation such to establish permanent contact between absorber and cover P Breaking or permanent deformation of collector fixing points or collector box P Vacuum loss P Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area P Other: -- Remarks / Osservazioni Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 11 of 23 § 5.4 TAB. 3A: Exposure test / Prova di esposizione Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................................... : 2010/04/05 Test end [YYYY/MM/DD] / Data fine 2010/05/26 prova [AAAA/MM/GG] ............................... : Collector tilt / Inclinazione del collettore [°]: 45 Collector azimuth / angolo azimutale del collettore rispetto al sud [°]: 0 Day Date Irradiation H [MJ/m2] Air temperature ta [°C] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 2010/04/05 2010/04/06 2010/04/07 2010/04/08 2010/04/09 2010/04/10 2010/04/11 2010/04/12 2010/04/13 2010/04/14 2010/04/15 2010/04/16 2010/04/17 2010/04/18 2010/04/19 2010/04/20 2010/04/21 2010/04/22 2010/04/23 2010/04/24 2010/04/25 2010/04/26 2010/04/27 2010/04/28 2010/04/29 2010/04/30 16.3 16.5 16.4 16.1 15.2 17.1 3.4 2.2 4.6 15.7 4.6 8.3 3.7 17.2 17.3 16.4 18.1 14.7 3.1 2.6 15.1 2.1 1.8 14.5 16.8 3.4 17 18 17 16 22 24 13 12 14 17 16 18 16 14 22 23 23 21 15 20 24 24 18 23 23 21 Rain Day Date Irradiation H [MJ/m2] Air temperature ta [°C] 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 2010/05/01 2010/05/02 2010/05/03 2010/05/04 2010/05/05 2010/05/06 2010/05/07 2010/05/08 2010/05/09 2010/05/10 2010/05/11 2010/05/12 2010/05/13 2010/05/14 2010/05/15 2010/05/16 2010/05/17 2010/05/18 2010/05/19 2010/05/20 2010/05/21 2010/05/22 2010/05/23 2010/05/24 2010/05/25 2010/05/26 2.7 1.8 3.1 17.4 1.2 16.2 4.5 14.8 3.8 6.3 5.4 7.2 8.4 7.7 15.4 16.1 17.4 18.2 18.4 18.3 18.2 18.7 19.1 19.6 19.3 18.4 18 15 18 12 13 15 12 17 17 18 18 18 18 16 20 22 22 22 20 24 25 26 26 27 27 24 2 Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2010/04/05 2010/04/06 2010/04/07 2010/04/08 2010/04/09 2010/04/10 2010/04/14 2010/04/18 2010/04/19 2010/04/20 2010/04/21 2010/04/22 2010/04/28 2010/04/29 2010/05/04 Irradiance G [W/m2] 904 901 891 926 919 900 909 872 901 901 903 906 903 909 895 Air temperature ta [°C] 17 18 17 16 22 24 17 14 22 23 23 21 23 23 12 2 Time periods [min] 73 60 70 51 51 64 66 71 86 46 81 71 76 76 97 Period Date 16 17 18 19 20 21 22 23 24 25 26 27 28 29 2010/05/06 2010/05/08 2010/05/15 2010/05/16 2010/05/17 2010/05/18 2010/05/19 2010/05/20 2010/05/21 2010/05/22 2010/05/23 2010/05/24 2010/05/25 2010/05/26 Irradiance G [W/m2] 909 920 896 896 910 899 885 978 878 909 873 906 880 908 Air temperature ta [°C] 15 17 20 22 22 22 20 24 25 26 26 27 27 24 Total hours with G > 850 W/m , air temperature > 10 ° C / Ore totali con G > 850 W/m2; temperatura ambiente > 10 °C : Report No. M1.10.SOLT.0400/40581-rev01 30 Total days in which H > 14 MJ/m / Giorni totali con H > 14 MJ/m2: Period Rain Time periods [min] 54 81 37 74 63 45 63 73 89 88 59 74 80 76 33 Page 12 of 23 § 5.4 TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione Test start [YYYY/MM/DD] 2010/05/26 Data inizio prova [AAAA/MM/GG] Test end [YYYY/MM/DD] 2010/05/26 Data fine prova [AAAA/MM/GG] Collector fluid loop / Circuito idraulico del collettore Potential problems Evaluation* Verdict Swelling of pipes and components / Rigonfiamenti di tubature e componenti 0 P Fluid leakages / Perdite di liquidi e sgocciolamenti 0 P Cracking / Rotture 0 P Warping / Deformazioni 0 P Corrosion / Corrosione 0 P Evaluation* Verdict 0 P 0 P 0 P 0 P Deformation/corrosion/leakage/loss of bonding of the absorber tubes and headers / Deformazioni/corrosione/perdite/distacchi dei tubi dell’assorbitore e dei raccordi 0 P Deformation/corrosion of the absorber mountings / Deformazioni/segni di 0 P 0 P Strength / Solidità 0 P Safety / Sicurezza 0 P Loss of function / Perdita di funzionalità N/A N/A Safety / Sicurezza N/A N/A Collector / Collettore Potential problems/failures Cracking/warping/corrosion/rain penetration of the collector box/fasteners Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli aggraffaggi Cracking/adhesion/elasticity of the seals/gaskets / Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni Cracking/crazing/buckling/delamination/ warping/outgassing of the cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto della copertura e/o del riflettore Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di bolle sul rivestimento dell’assorbitore corrosione dei dispositivi di montaggio e fissaggio dell’assorbitore Water retention/outgassing/degradation of the thermal insulation / Ritenzione d’acqua/perdita di vuoto/ degradazione dell’isolante termico Mounting structure / Strutture di montaggio Safety equipment / Equipaggiamento di sicurezza *Evaluation scale / Scala di valutazione: 0 - No problem / Nessun problema 1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore 2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili N/A - Inspection to establish the condition was not possible / Ispezione non possibile Remarks / Osservazioni Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 13 of 23 § 5.5 TAB. 4: External thermal shock test / Prova dello shock termico esterno Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : 2010/04/21 Test installation / Installazione di prova Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... : Outdoor 2010/05/21 Indoor Test combined with exposure test / Test combinato con il test di esposizione Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte temperature Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova è stata effettuata su di un collettore a tubi evacuati The temperature of the collector was measured at the location shown below: / La -- temperatura del collettore è stata misurata nella posizione illustrata di seguito: Additional information required if the absorber temperature was measured using a special fluid: The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to the average absorber temperature of …....….… °C Shock n° Test conditions / Condizioni di prova Test date / data di prova Collector tilt angle [°] / Angolo di inclinazione del collettore [°] 2 Average irradiance [W/m ] / Irraggiamento medio [W/m2] 2 Minimum irradiance [W/m ] / Irraggiamento minimo [W/m2] Average air temperature [°C] / Temperatura ambiente media [°C] Minimum air temperature [°C] / Temperatura amb. minima [°C] Preconditioning period [min] / Durata di precondizionamento [min] Absorber temp. before spraying [°C] / Temp. dell’assorbitore prima del getto [°C] 2 Flow rate of water spray [kg/(s·m )] / Portata del getto d’acqua [kg/(s•m2)] Temperature of water spray [°C] / Temperatura del getto d’acqua [°C] Duration of water spray [min] / Durata del getto d’acqua [min] Potential failure. / Danno potenziale -- 1 2 2010/04/21 45 927 902 23.2 22.9 61 78.2 0.031 16.5 15 2010/05/21 45 976 954 25.1 24.6 62 78.9 0.033 17.2 16 Failure occurred/ danneggiamenti occorsi Absorber leakage Deformation such to establish permanent contact between absorber and cover Breaking or permanent deformation of collector fixing points or Results / Risultati collector box Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Other: Remarks / Osservazioni : Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 14 of 23 § 5.6 TAB. 5: Internal thermal shock test / Prova dello shock termico interno Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : 2010/04/22 Test installation / Installazione di prova Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... : Outdoor 2010/05/26 Indoor Test combined with exposure test / Test combinato con il test di esposizione Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte temperature Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova è stata effettuata su di un collettore a tubi evacuati The temperature of the collector was measured at the location shown below: / La -- temperatura del collettore è stata misurata nella posizione illustrata di seguito: Additional information required if the absorber temperature was measured using a special fluid: The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to the average absorber temperature of …....….… °C Shock n° 1 2 2010/04/22 2010/05/26 45 45 946 949 Minimum irradiance W/m ] / Irraggiamento minimo [W/m ] 911 934 Average air temperature [°C] / Temperatura ambiente media [°C] 21.2 24.8 Minimum air temperature [°C] / Temperatura amb. minima [°C] 20.8 24.4 Preconditioning period [min] / Durata di precondizionamento [min] 62 64 Absorber temp. before flowing [°C] / 77 78 Flow rate of heat transfer fluid [kg/(s·m )] / Portata di fluido 0.022 0.023 Temperature of heat transfer fluid [°C] / 17.2 17.9 7 6 Test date / data di prova Collector tilt angle [°] / Angolo di inclinazione del collettore [°] 2 Average irradiance W/m ] / Irraggiamento medio [W/m2] 2 Test conditions / Condizioni di prova -- 2 Temp. dell’assorbitore prima del flusso [°C] 2 termovettore [kg/(s•m2)] Temperatura del fluido termovettore [°C] Duration of flow [min] / Durata del flusso [min] Potential failure. / Danno potenziale Failure occurred/ danneggiamenti occorsi Absorber leakage Deformation such to establish permanent contact between absorber and cover Breaking or permanent deformation of collector fixing points or Results / Risultati collector box Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Other: Remarks / Osservazioni : Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 15 of 23 § 5.7 TAB. 6: Rain penetration test / Prova di penetrazione della pioggia Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : 2010/05/19 Test installation / Installazione di prova Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] ....................: Outdoor Collector mounted on / Collettore Indoor Simulated roof / Tetto simulato Open frame/ Struttura aperta montato su: Method used to keep the absorber warm / Metodo usato per mantenere caldo il collettore: 2010/05/19 Hot water circulation / Circolazione di acqua calda Exposure of collector to solar radiation / Esposizione del collettore alla radiazione solare Collector tilt angle [°] / 45 Angolo di inclinazione del collettore [°] 2 Water flow rate [kg/(s·m )] / Portata di fluido termovettore [kg/(s•m2)] 0.053 Temperature of heat transfer fluid [°C] / 54.2 Test conditions / Condizioni di prova Temperatura del fluido termovettore [°C] Duration of water spray [h] / Durata del getto d’acqua [h] 4 Potential failure. / Danno potenziale Failure occurred/ danneggiamenti occorsi Water penetration Absorber leakage Deformation such to establish permanent contact between absorber and cover Results / Risultati Breaking or permanent deformation of collector fixing points or collector box Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Other: Remarks / Osservazioni : No rain penetration / nessuna penetrazione di pioggia No failure detected / Nessun danneggiamento rilevato Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 16 of 23 § 5.8 TAB. 7: Freeze resistance test / Prova di resistenza al gelo Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : Collector type / Tipo di collettore 2010/03/29 Test end [YYYY/MM/DD] / 2010/03/29 : Data fine prova [AAAA/MM/GG] Freeze-resistant when filled with water Drain-down Antifreeze fluid (MS) / Liquido antigelo specificato dal costruttore Water- Propylene glycol mixture / Miscela acqua-glicole propilenico Tilt angle of the collector [°] / Test conditions / Condizioni di prova N° of freezethaw cycle -- Angolo di inclinazione del collettore [°] Rate of chamber cooling [K/h] / Velocità di raffreddamento [K/h] -- Rate of chamber heating [K/h] / Velocità di riscaldamento [K/h] -- Freeze conditions / Condizioni di congelamento Thaw conditions / Condizioni di scongelamento Test temperature [°C] Duration [min] Test temperature [°C] Duration [min] 1 -- -- -- -- 2 -- -- -- -- 3 -- -- -- -- Potential failure / Potenziale danneggiamento Results / Risultati Failure occurred/ Verdict Absorber leakage -- Deformation such to establish permanent contact between absorber and cover -- Breaking or permanent deformation of collector fixing points or collector box -- Vacuum loss -- Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area -- Other: -- Remarks / Osservazioni: The manufacturer recommends the use of a water-sodium chloride mixture in the solar loop. / Il costruttore raccomanda l’utilizzo di una miscela acqua-cloruro di sodio nel circuito solare. Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS (see Remarks) Page 17 of 23 § 5.9 TAB. 8: Mechanical load test / Prova di carico meccanico POSITIVE PRESSURE TEST OF THE COLLECTOR COVER Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : 2010/07/30 Test end [YYYY/MM/DD] / : Data fine prova [AAAA/MM/GG] 2010/07/30 Loading with gravel or similar material Method used to apply positive Loading with water pressure to the cover / Metodo usato per Suction cups applicare il carico positivo alla copertura Pressurisation of collector cover Test conditions / Condizioni di prova 1000 Maximum pressure load [Pa] / Pressione di carico massima [Pa] Remarks / Note Negative pressure test of fixings between the cover and collector box Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : Test end [YYYY/MM/DD] / -- : Data fine prova [AAAA/MM/GG] -- Method used to apply negative Suction cups pressure to the cover / Metodo usato per applicare il carico negativo alla copertura Pressurisation of collector box N/A Test conditions / Condizioni di prova Maximum pressure load [Pa] / Pressione di carico massima [Pa] Remarks / Note This test is not applicable to the E.u.T. / Questa prova non è applicabile al collettore Negative pressure test of collector mountings Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ : Test end [YYYY/MM/DD] / -- : Data fine prova [AAAA/MM/GG] -- Method used to apply negative Suction cups pressure to the cover / Metodo usato per applicare il carico negativo alla copertura Air bags N/A Test conditions / Condizioni di prova Maximum pressure load [Pa] / Pressione di carico massima [Pa] Remarks / Note This test is not applicable to the E.u.T. / Questa prova non è applicabile al collettore Results / Risultati Failure occurred/ Potential failure. / --. Verdict Absorber leakage -- Deformation such to establish permanent contact between absorber and cover -- Breaking or permanent deformation of collector fixing points or collector box -- Vacuum loss -- Other: -- Remarks / Osservazioni: Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 18 of 23 § 5.11 TAB. 9: Final inspection / Ispezione finale Test start [YYYY/MM/DD] 2010/07/30 Data inizio prova [AAAA/MM/GG] Test end [YYYY/MM/DD] 2010/07/30 Data fine prova [AAAA/MM/GG] Collector loop pipes / Tubazioni del circuito collettore Potential problems Evaluation* Verdict Swelling of pipes and components / Rigonfiamenti di tubature e componenti 0 P Fluid leakages / Perdite di liquidi e sgocciolamenti 0 P Cracking / Rotture 0 P Warping / Deformazioni 0 P Corrosion / Corrosione 0 P N/A N/A Evaluation* Verdict 0 P 0 P 0 P 0 P Deformation/corrosion/leakage/loss of bonding of the absorber tubes and headers / Deformazioni/corrosion/perdite/distacchi dei tubi dell’assorbitore e dei raccordi 1 P Deformation/corrosion of the absorber mountings / Deformazioni/segni di corrosion 0 P 0 P Strength / Solidità 0 P Safety / Sicurezza 0 P Loss of function / Perdita di funzionalità N/A N/A Safety / Sicurezza N/A N/A Water retention/outgassing/degradation of the insulation / Ritenzione d’acqua / Perdita del vuoto / degradazione dell’isolamento Collector / Collettore Potential problems/failures Cracking/warping/corrosion/rain penetration of the collector box/fasteners Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli aggraffaggi Cracking/adhesion/elasticity of the seals/gaskets / Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni Cracking/crazing/buckling/delamination/ warping/outgassing of the cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto della copertura e/o del riflettore Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di bolle sul rivestimento dell’assorbitore dei dispositive di montaggio e fissaggio dell’assorbitore Water retention/outgassing/degradation of the thermal insulation / Ritenzione d’acqua/perdita di vuoto/ degradazione dell’isolante termico Mounting structure / Strutture di montaggio Safety equipment / Equipaggiamento di sicurezza *Evaluation scale / Scala di valutazione: 0 - No problem / Nessun problema 1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore 2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili N/A - Inspection to establish the condition was not possible / Ispezione non possibile Remarks / Osservazioni: Some negligible water leakage from risers near the manifold / alcune perdite trascurabile dai canali di innalzamento in prossimità del tubo collettore Verdict / Esito Report No. M1.10.SOLT.0400/40581-rev01 PASS Page 19 of 23 §6 TAB. 10: Thermal performance / Prestazioni termiche Test start [YYYY/MM/DD] 2010/03/29 Data inizio prova [AAAA/MM/GG] Test method / Metodo di prova Test end [YYYY/MM/DD] 2010/07/30 Data fine prova [AAAA/MM/GG] 6.2 Outdoor – Steady state 6.2 Indoor – Steady state method 44° 52’ N Longitude / Longitudine: Latitude / Latitudine: Collector tilt / Inclinazione del collettore [°] 6.3 Outdoor – quasi-dynamic 08° 48’ E Collector azimuth /Orientamento azimutale del 45 South / Sud collettore Orientation of absorber tubes during testing / Orientamento dei tubi del collettore durante la prova Vertical/ verticale Flow rate used for performance testing (average) / Flusso utilizzato per il test (valore medio) [kg/s]: 0.043 Test results / Risultati di prova Condizioni ambientali m isurate DATA POINTS Tamb 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Net Irradiance Global irradiance G" G [W/m 2] [W/m2] (T a) [°C] W ind speed [m/s] 28,0 0,84 966,0 28,0 28,3 0,61 0,86 959,0 968,0 28,3 0,48 28,7 Grandezze derivate Grandezze collettore misurate Reduced temp. difference Actual u seful power [W] Istantaneous efficiency (APERTURE) Istantan eous efficiency (ABSORBER) 0,26 0,00035 1591,54 0,95 0,97 0,16 0,00021 1591,66 0,94 0,95 4,1786 5,36 0,00698 1507,07 0,89 0,91 33,64 4,1786 5,34 0,00673 1506,81 0,86 0,88 3,78 40,29 4,1793 11,59 0,01502 1389,83 0,82 0,83 5,28 3,78 40,29 4,1793 11,59 0,01562 1390,25 0,85 0,87 29,38 5,28 4,08 27,34 4,1791 1,34 0,00177 1499,39 0,90 0,92 25,40 29,46 5,30 4,06 27,43 4,1791 1,33 0,00179 1498,48 0,92 0,94 743,2 30,40 34,25 5,28 3,85 32,32 4,1786 5,92 0,00797 1414,50 0,87 0,88 948,4 792,1 30,40 34,25 5,28 3,85 32,32 4,1786 5,82 0,00735 1414,50 0,81 0,83 1,72 946,3 763,3 36,40 39,83 5,27 3,43 38,11 4,1790 12,01 0,01574 1258,24 0,75 0,76 25,9 1,65 935,5 766,1 36,40 39,85 5,27 3,45 38,13 4,1790 12,22 0,01595 1266,64 0,75 0,77 27,8 2,82 925,9 758,5 26,10 30,12 5,28 4,02 28,11 4,1789 0,31 0,00041 1479,09 0,89 0,90 27,7 2,97 927,6 740,9 26,00 30,01 5,30 4,01 28,01 4,1790 0,31 0,00041 1481,88 0,91 0,93 27,6 2,79 923,8 762,1 31,80 35,07 5,29 3,27 33,43 4,1786 5,83 0,00766 1204,13 0,72 0,73 27,6 2,60 926,0 732,1 31,80 35,11 5,28 3,31 33,45 4,1786 5,85 0,00799 1214,97 0,75 0,77 27,9 27,8 3,01 2,69 935,7 930,6 751,4 745,7 38,00 38,00 40,72 40,69 5,30 5,28 2,72 39,36 4,1791 11,46 0,01525 1002,91 0,61 0,62 2,69 39,35 4,1791 11,55 0,01548 989,66 0,60 0,61 Tin [°C] Tout [°C] Flow-Rate [l/min] DeltaT [K] Mea n fluid temp. T m [°C] cf 758,2 26,10 30,43 5,28 4,33 28,26 4,1789 773,1 767,6 26,00 31,60 30,32 35,71 5,28 5,26 4,32 28,16 4,1789 4,11 33,66 963,5 794,4 31,60 35,69 5,29 4,09 0,75 964,0 771,5 38,40 42,18 5,28 28,7 0,78 941,0 742,2 38,40 42,18 26,0 1,52 947,6 756,3 25,30 26,1 1,56 943,8 741,9 26,4 1,42 946,5 26,5 1,47 26,1 2 Tm-Ta [K] 2 Peak power for G” = 1000 W/m and u = 0 m/s / Potenza di picco per G” = 1000 W/m Tm – Ta = 2 K e u = 0m/s [W] 2038 POWER OUTPUT per collector unit / Potenza resa per unità di collettore Net irradiance G” G” = 400 W /m 2 G” = 700 W /m 2 G” = 1000 W /m u = 0.0 m/s 784 1408 2038 u = 1.0 m/s 745 1356 1974 u = 1.5 m/s 726 1329 1942 u = 2.0 m/s 706 1303 1910 u = 2.5 m/s 687 1277 1878 u = 3.0 m/s 667 1251 1846 u = 3.5 m/s 648 1224 1814 2 Remarks / Osservazioni: Report No. M1.10.SOLT.0400/40581-rev01 Page 20 of 23 §6 TAB. 10: Thermal performance / Prestazioni termiche 2 Diagram of power output for windspeed u < 1m/s and G” = 1000 W/m / Grafico per velocità del vento < 1 m/s e G” = 1000 W/m2 2500 Power-0m/s 2000 Power-1m/s 1500 1000 500 0 0 10 20 30 40 50 60 70 80 90 100 2 Diagram of power output for windspeed u = 1.5 ± 0.5 m/s and G” = 1000 W/m / Grafico per velocità del vento = 1.5 ± 0.5 m/s e G” = 1000 W/m2 2500.00 Power-1m/s 2000.00 Power-1.5m/s Power-2m/s 1500.00 1000.00 500.00 0.00 0 10 20 30 40 50 60 70 80 90 100 2 Diagram of power output for windspeed u = 3 ± 0.5 m/s and G” = 1000 W/m / Grafico per velocità del vento = 3 ± 0.5 m/s e G” = 1000 W/m2 2500.00 Power-2.5m/s 2000.00 Power-3m/s Power-3.5m/s 1500.00 1000.00 500.00 0.00 0 10 20 Report No. M1.10.SOLT.0400/40581-rev01 30 40 50 60 70 80 90 100 Page 21 of 23 §6 TAB. 10: Thermal performance / Prestazioni termiche 2 Efficiency curve for G” = 800 W/m and windspeed u= 1.5 m/s / - Reference area APERTURE Curva di efficienza per G” = 800 W/m2 – Velocità del vento u = 0 m/s /, u= 1.5 m/s and u = 3 m/s 1.0 u=0 m/s 0.9 u=1.5 m/s 0.8 u=3 m/s 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 Parameters for efficiency equation / Parametri dell’equazione di efficienza Parameter Absorber area Aperture area Gross area η0 [] 0.95 0.93 0.89 b1 [W/m K] 6.55 6.43 6.15 b2 [W/m K ] 4.03 3.96 3.78 bu [] 0.02 0.02 0.02 2 2 2 Remarks / Osservazioni: Report No. M1.10.SOLT.0400/40581-rev01 Page 22 of 23 §6 TAB. 10: Thermal performance / Prestazioni termiche 0.99 Incidence Angle Modifier (IAM) at 50° / Fattore di angolo di incidenza a 50°............... ........................... [ ] 50° ° 0° 10° 20° 30° 40° 60° 70° 80° 90° Kθ longitudinal - IAML 1 1 1 1 1 0.99 0.97 0.92 0.66 0.00 Kθ transversal IAMT 1 1 1 1 1 0.99 0.97 0.92 0.66 0.00 IAMT IAML 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 80 Remarks / Osservazioni: Time constant τc / Costante di tempo .................................................................................................................... [s] 143 Remarks / Osservazioni: The time constant τc of the collector has been measured as the time elapsed between the removal of a cover used to achieve a steady state condition of the water temperature at the outlet and the point where the collector outlet temperature rises to 63,2 % of the total increase up to the next steady state condition. La costante di tempo τc del collettore è stata misurata come il tempo trascorso tra la rimozione del rivestimento usato per raggiungere la condizione stazionaria della temperatura dell’acqua all’uscita e al punto dove la temperatura di uscita del collettore sale a 63,2% dell’incremento totale alla successiva condizione stazionaria. Effetcive thermal capacity / Capacità termica effettiva ...................................................................................... [kJ/K] 33.6 Remarks / Osservazioni: La capacità termica effettiva è calcolata dalle registrazioni misurate di tin, ∆Τ, ta, G utilizzando la seguente relazione per test all’aperto: The effective thermal capacity is calculated from or from the measurement records of tin, ∆Τ, ta , G and by the following relation for outdoor testing : ----------------- End of Test Report No. M1.10.SOLT.0400/40581-rev01 -----------------Report No. M1.10.SOLT.0400/40581-rev01 Page 23 of 23