10156 TORINO (ITALY) – 21, Via Cuorgnè Tel. +39.011.22.22.225 – Fax +39.011.22.22.226 – e-mail: [email protected] – web: www.eurofins.com TEST REPORT EN 12975-2: 2006: Thermal solar systems and components - Solar collectors – Part2: Test methods Impianti solari termici e loro componenti - Collettori solari - Parte 2: Metodi di prova Report Reference No./ Numero rapporto .. : M1.11.NRG.0354/45417 Date of issue / Data di emissione ................ : 2011-09-27 Total number of pages / N° tot. di pagine.... : 24 Testing Laboratory / Laboratorio di prova .. : Eurofins – Modulo Uno S.p.A. Address / Indirizzo .................................. : Strada Comunale Savonesa, 9 – 15057 Rivalta Scrivia (AL) - ITALY Applicant’s name / Nome del richiedente ... : ZOCCHI GROUP S.r.l. Address / Indirizzo .................................. : Via degli Artigiani, 10 - 20010 - Buscate (MI) – ITALY Test specification / Specifiche di prova Standard / Norma ................................... : Non-standard test method .................. : EN 12975-2:2006 (+ ANNEX P - Draft Annex for prEN 12975-2 dated 2011-05-18) N/A Metodo di prova non standard Scope of the test / Scopo della prova To assess the ability to resist the influence of degrading agents and to determine the steady-state and quasidynamic thermal performance of glazed and unglazed liquid heating solar collectors, within the scope of UNI EN 12975-1:2011 “Thermal solar systems and components – Solar collectors - Part 1: General requirements”. Verifica della capacità di un collettore solare termico per il riscaldamento di liquidi, vetrato o non vetrato, di resistere all’influenza di agenti di degradazione e caratterizzazione delle prestazioni termiche in condizioni stazionarie e quasi dinamiche, nello scopo della norma UNI EN 12975-1: 2011: Sistemi e componenti solari termici – Collettori solari – Parte 1: Requisiti generali”. Test item description ........................: Descrizione dell’oggetto in prova CONCENTRATING - Liquid heating parabolic solar collector Collettore solare parabolico a concentrazione per il riscaldamento di liquidi Trade Mark ......................................... : Marchio Manufacturer / Costruttore ....................... : ZOCCHI GROUP S.r.l. Address / Indirizzo .................................. : Via degli Artigiani, 10 - 20010 - Buscate (MI) – ITALY Model/Type reference / Modello ............. : ZSOLEX Date of receipt of the test item ............ : 2011/07/22 Data di ricevimento dell’oggetto in prova Testing period / Periodo di prova ................ : 2011/07/22 ÷ 2011/09/26 This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. The test results presented in this report relate only to the object tested. Eurofins Modulo Uno S.p.A. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia. I risultati esposti in questo rapporto di prova si riferiscono esclusivamente all’oggetto testato. Eurofins Modulo Uno S.p.A. non assume alcuna responsabilità per danni derivanti dall’interpretazione del lettore del materiale riprodotto al di fuori del suo contesto. 0 Ing. Giovanni Bellenda Revision n° Head of Renewable Energy Unit. Summary / Sommario GENERAL INFORMATION / INFORMAZIONI GENERALI__________________________________3 Description of test item construction / Descrizione della costruzione dell’oggetto in prova _______4 Test summary statement / Attestazione di prova_____________________________________8 Record of test sequence and summary of main results / Sequenza delle prove ______________8 TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici__9 TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici____ 10 TAB. 2: High temperature resistance / Resistenza alle alte temperature ____________________11 TAB. 3A: Exposure test / Prova di esposizione _______________________________________12 TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione _______________13 TAB. 4: External thermal shock test / Prova dello shock termico esterno ____________________14 TAB. 5: Internal thermal shock test / Prova dello shock termico interno ____________________15 TAB. 6: Rain penetration test / Prova di penetrazione della pioggia ________________________16 TAB. 7: Freeze resistance test / Prova di resistenza al gelo ______________________________17 TAB. 8: Mechanical load test / Prova di carico meccanico_______________________________18 TAB. 9: Impact resistance test (optional)/ Resistenza all’impatto (opzionale) ________________19 TAB. 10: Final inspection / Ispezione finale ________________________________________20 TAB. 11A: Thermal performance – Measurements’ results / Prestazioni termiche – Risultati delle misure _________________________________________________________________________21 TAB. 11B: Thermal performance – Test results / Prestazioni termiche – Risultati della prova ______ 22 ANNEX 1: Equipment list / Elenco degli strumenti ed attrezzature ________________________23 ANNEX 3: Schematic f the test circuit for performance tests / Schema del circuito di prova per le prove di prestazione termica _________________________________________________________24 Report No. M1.11.NRG.0354/45417 Page 2 of 24 GENERAL INFORMATION / INFORMAZIONI GENERALI General remarks / Note generali: • This publication may be reproduced in whole or in part for non-commercial purposes as long as Eurofins Modulo Uno S.p.A. is acknowledged as copyright owner and source of the material and only with the written permission. Questa pubblicazione può essere riprodotta per intero o parzialmente per scopi non commerciali a condizione che Eurofins Modulo Uno S.p.A. sia riconoscibile come proprietaria dei diritti d’autore e fonte del materiale e solo con autorizzazione scritta. • The test results presented in this report relate only to the object tested. I risultati esposti in questo rapporto di prova si riferiscono esclusivamente all’oggetto testato. • This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia. • "(see annex #)" refers to additional information include in the report. “(vedi allegato #)” è un riferimento ad informazioni aggiuntive incluse al rapporto • "(see tab. #)" refers to a table included in the report. “(vedi tab.#)” è un riferimento ad una tabella annessa al rapporto • Throughout this report a point is used as the decimal separator. In questo rapporto di prova come separatore decimale è utilizzato il punto. Testing location(s): Eurofins - Modulo Uno S.p.A. Strada Comunale Savonesa, 9 15050 Rivalta Scrivia (AL) – Italy Sito(i) di prova Latitude / Latitudine: 44° 52’ N Longitude / Longitudine: 08° 48’ E Tel. +39 011 2222225 Fax +39 011 2222226 e-mail: [email protected] web: www.product-testing.eurofins.com Tests performed (name of test and test clause) ........................ : EN 12975-2 – all applicable clauses (+ ANNEX P - Draft Annex for prEN 12975-2 dated 2011-05-18) Prove eseguite (nome ed articolo del test) Possible test case verdicts / Esiti di prova possibili : - test case does not apply to the test object / il requisito non è applicabile all’oggetto in prova .......... : N/A - test object does meet the requirement / l’oggetto in prova rispetta il requisito .............................. : Pass (P) - test object does not meet the requirement / l’oggetto in prova non rispetta il requisito ................... : Fail (F) Abbreviations used in this report / Abbreviazioni usate in questo rapporto: Manufacturer’s Specification / Specifica fornita dal costruttore ...................................................... : MS Equipment under Test / Oggetto in prova................................................................................... : E.u.T. Mean temperature of heat transfer fluid [°C] ..... ................................................................... : tm Ambient or surrounding air temperature [°C] ....... ................................................................. : Ta or ta -2 Global hemispherical solar irradiance [Wm ] ....................................................................... : 2 -1 G* Reduced temperature difference ( = (tm – Ta)/G*) [m KW ].................................................. : T*m Zero-loss collector efficiency (η at T*m = 0), reference to T*m ............................................... : η0 -2 -1 Heat loss coefficient [Wm K ] ............................................................................................ : -2 -2 Temperature dependence of the heat loss coefficient [Wm K ] .......................................... : 2 Absorber area of collector [m ] .............................................................................................. : 2 Aperture area of collector [m ]............................................................................................... : 2 Gross area of collector [m ] ................................................................................................... : -1 -1 Specific heat capacity of heat transfer fluid [Jkg K ] ........................................................... : Report No. M1.11.NRG.0354/45417 a1 a2 AA Aa AG cf Page 3 of 24 Description of test item construction / Descrizione della costruzione dell’oggetto in prova (Manufactories and part numbers, unless otherwise specified / Costruttori e part number, se non diversamente specificato) Orderer / Richiedente ............................. : ZOCCHI Group S.r.l. Via degli Artigiani, 10 - 20010 - Buscate (MI) – Italy Expeller / Rivenditore ............................. : ZOCCHI Group S.r.l. Via degli Artigiani, 10 - 20010 - Buscate (MI) – Italy Manufacturer / Costruttore ..................... : ZOCCHI Group S.r.l. Via degli Artigiani, 10 - 20010 - Buscate (MI) – Italy Sampling procedure / Procedura di campionamento........................................ : Random sampling from production / Campionamento casuale dalla produzione Prototype submitted by client / Prototipo fornito dal cliente Brand name / Nome commerciale ............ : ZSOLEX Serial number / Numero di serie .............. : 000002 Lab. identification codes / Codici identificativi del laboratorio .......................... : 10.0632 Photograph(s) of the E.u.T. / Foto dell’oggetto in prova Report No. M1.11.NRG.0354/45417 Page 4 of 24 Ratings / Dati tecnici nominali Max working temperature [°C] / Massima temperatura operativa [°C] ............................ : Max working pressure [bar] / Massima pressione operativa [bar] .................................. : 2 Rated (recommended) flow rate [l/m h] / Portata nominale (consigliata) [l/m2h] ............. : 250 6 30 Collector / Collettore Manufacturer / Costruttore ............................ : ZOCCHI Group S.r.l. Model / Modello ........................................... : ZSOLEX Glazed flat plate / Vetrato piano Vacuum tube – Heat pipe single glass tube / Tubi evacuati – Tubo di calore singola copertura vetrata Vacuum tube – Heat pipe double glass tube / Tubo di calore doppia copertura vetrata Collector type / Tipo di collettore ................ : Vacuum tube – U Tube / Tubi evacuati – Tubi a U Vacuum tube – filled with water / Tubi evacuati riempiti d’acqua Without covering – unglazed / Scoperto - non vetrato Other / Altro : concentrazione Tracking parabolic single point concentrator / collettore solare parabolico puntuale a Serial product / Prodotto di serie ............................................................................. : YES / SÌ Drawing number / N° di disegno ............................................................................ : -- Serial number / Numero di serie ............................................................................. : 000002 Date when manufactured / data di costruzione ........................................................ 2010 Collector loop flow range [kg/s] / Campo di flusso del circuito collettore [kg/s] ................... : 0.005 ÷ 0.04 Operating pressure [kPa] / Pressione di esercizio ..................................................... : -- NO 2 Stagnation temperature at 1000 W/m and 30°C ambient temperature [°C] / Temperatura di stagnazione a 1000 W/m2 e 30°C di temperature ambiente [°C] ................................ : Collector mounting / Montaggio del collettore ............................................................ : -on metal support with tracking system / su supporti metallic con sistema di inseguimento Support metal frame material (if any) Materiale del supporto metallico N° of collectors / N° di collettori (se esistente) ........ : ............................................................................. : Gross length [mm] / Lunghezza lorda [mm] ............................................................... : Gross width [mm] / Larghezza lorda [mm] ................................................................. : Gross height [mm] / Altezza lorda [mm] ................................................................... : 2 Gross area [m ] / Superficie lorda [m2]: 2 Aperture area [m ] / Superficie di apertura [m2]: 2 Iron - steel 1 1600 (Parabolic concentarator diameter /Diametro del concentratore parabolico) 1600 (Parabolic concentarator diameter /Diametro del concentratore parabolico) 1700 (including stand and and gear box / compresi supporti e gruppo motorizzato): 2.10 2.00 Absorber area [m ] / Superficie assorbitore [m2]: 0.03 Weight empty [kg] / Peso a vuoto [kg]: 56 Report No. M1.11.NRG.0354/45417 Page 5 of 24 Weight without glazing [kg] / Peso senza copertura vetrata [kg] -- Fluid capacity [l] / Capacità di contenimento di fluido [l] 4 Number of covers / Numero di coperture -- Cover material / Materiale copertura -- Cover thickness [mm] / Spessore copertura [mm] -- Cover solar transmittance [%] / Trasmittanza solare della copertura [%] .......................... : -- Absorber material / Materiale assorbitore : Aluminum / Alluminio Absorber’s dimensions / Dimensioni dell’assorbitore ................................................... : Cylindrical tank - Length 303 mm, ext. diameter 150 mm / Recipiente cilindrico - Lunghezza 303 mm, diametro esterno 150 mm Absorber’s thickness [mm] / Spessore dell’assorbitore [mm] ........................................ -- Absorber dry weight [kg] / Peso a vuoto dell’assorbitore [kg] ......................................... : 2 Absorber – Fin width [mm] / Larghezza alette dell’assorbitore [mm] ................................ : -- Absorber – Fin thickness [mm] / Spessore alette dell’assorbitore [mm] ........................... : -- Solar absorptance α / Fattore di assorbimento solare α ............................................... : -- Hemispherical emittance ε / Emittanza emisferica ε .................................................. : -- Surface treatment / Trattamento superficiale.............................................................. : -- Construction type / Tipo di costruzione .............................................................. : -- Number of risers / Numero di tubi di innalzamento ........................................................ : -- Riser diameter or dimensions / Dimensioni o diametro dei tubi di innalzamento .................. : -- Distance between risers / Distanza tra i tubi di innalzamento ......................................... : -- Back thermal insulation thickness / Spessore dell’isolamento termico posteriore ............... : 25 Side thermal insulation thickness / Spessore dell’isolamento termico laterale................... : 25 Insulation material / Materiale isolante Rockwool .............................................................. : Casing material / Materiale di contenimento .............................................................. : -- Sealing material / Materiale di sigillatura .............................................................. : -- Other limitations / Altre limitazioni .............................................................. : -- Report No. M1.11.NRG.0354/45417 Page 6 of 24 Comments on collector design / Commenti sul progetto del collettore ............................ : Heat transfer medium / Mezzo termovettore ............................................................ : None / Nessuno Water- glycol mixture / Miscela acqua-glicole Alternative acceptable heat transfer None / nessuno fluids / Fluido termovettore alternative accettabile : Test item particulars: / Particolari dell’oggetto in prova: The collector is mounted on a motorized structure driven by a control unit suitable both to track the sun and to implement the safety functions required. / Il collettore è montato su di una struttura metallica motorizzata pilotata da una unità elettronica adatta a realizzare la funzione di inseguimento del sole e ad implementare le funzioni di sicurezza richieste Accessories and detachable parts included in the evaluation / Accessori e parti separabili incluse nella valutazione.................................................................................. : -- Options included / Opzioni incluse ......................................................................... : Sketch of the collector / Schema del collettore Schematic diagram of the absorber / Diagramma schematico dell’assorbitore Component list / Distinta dei componenti Item / Componente Supplier / Fornitore Item code / Codice Notes-material / Note - materiale componente Parabolic concentrator Concentratore parabolico Absorber Assorbitore Manifold tubes Tubi collettore Absorber tubes Tubi assorbitore Collector insulation Isolante collettore Collector back sheet Fondo collettore Absorber mounting structure -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Struttura di supporto dell’assorbitore Tape sealant Sigillante a nastro Report No. M1.11.NRG.0354/45417 Page 7 of 24 Test summary statement / Attestazione di prova The product tested as described on page 1 through 7 complies with the requirements of the nd standard(s) mentioned on page 1, as detailed below. The measurements were carried out from 22 th July 2011 to 25 September 2011. No problems or relevant observations occurred during the measurements. Il prodotto testato, come descritto nelle pagine da 1 a 7, rispetta i requisiti della(e) norma(e) citata (e) a pagina 1, come dettagliato nel seguito. Le misure sono state effettuate dal 22 luglio 2011 al 25 settembre 2011. Durante le misure non è stato evidenziato nessun problema né rilievo significativo. Record of test sequence and summary of main results / Sequenza delle prove Clause Date / Data Clause EN 129751 EN 129752 5.3.2 5.2 5.3.3 5.3 Test / Prova Results – remarks / Risultati -note VERDICT 2011/07/29 (see Tab. 1A) P 2011/08/10 2011/08/10 (see Tab. 2) P 2011/07/22 2011/09/25 (see Tab. 3) P (see Tab. 4) P (see Tab. 5) N/A Start / End / Inizio Fine 2011/07/29 Internal pressure for absorbers / Pressione interna degli assorbitori High temperature resistance / Resistenza alle alte temperature 5.3.4 5.4 Exposure test / Prova di esposizione 5.3.5 5.3.6 5.5 5.6 5.3.7 5.7 5.3.10 5.8 5.3.8 5.9 4.1.7 5.10 -- 5.11 5.3.9 6 External thermal shock / First 2011/07/25 2011/07/25 Prova dello shock termico esterno Second 2011/08/19 2011/08/19 Internal thermal shock / First Prova dello shock termico interno Second Rain penetration test / 2011/07/29 2011/07/29 (see Tab. 6) P -- -- (see Tab. 7) P 2011/08/25 2011/08/25 (see Tab. 8) N/A -- -- Not performed (see Tab. 9) -- 2011/09/25 2011/09/25 (see Tab. 10) P 2011/07/22 2011/09/25 See/vedi Tab. 11 -- Prova di penetrazione della pioggia Freeze resistance test / Prova di resistenza al gelo Mechanical load test/ Prova di carico meccanico Impact resistance test (optional)/ Prova di resistenza all’impatto (opzionale) Dismantling final inspection / Ispezione finale di smontaggio Thermal performance testing / Prova delle prestazioni termiche Report No. M1.11.NRG.0354/45417 Page 8 of 24 § 5.2 TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici Test start [YYYY/MM/DD] / 2011/07/22 Data inizio prova [AAAA/MM/GG] Test installation / Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... Outdoor Installazione di prova : 2011/07/22 Indoor Maximum allowed working pressure MS [kPa] / Massima pressione di esercizio ammessa specificata dal 400 costruttore [kPa] Test ambient temperature [°C] / Test conditions / Condizioni di prova 26.5 Temperatura ambiente di prova [°C] 600 Test pressure [kPa] / Pressione di prova [kPa] 15 Test duration [min] / Durata di prova [min] Results / Risultati Failure occurred/ Potential failure / --. Verdict Absorber leakage P Deformation such to establish permanent contact between absorber and cover P Breaking or permanent deformation of collector fixing points or collector box P N/A Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area P Other: P Remarks / Osservazioni: None Verdict / Esito PASS Report No. M1.11.NRG.0354/45417 Operator / Operatore Enrico Martino Page 9 of 24 § 5.2 TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ............... -- Test installation / Installazione Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... Outdoor di prova -- Indoor Method used to pressurize the absorber / Metodo usato per pressurizzare il collettore: Pneumatic Hydraulic Method used to keep the absorber warm / Metodo usato Solar simulator Natural sunlight Heated water bath Heated pressurized circuit per mantenere caldo il collettore: Maximum allowed working pressure MS [kPa] / Massima pressione di esercizio specificata dal costruttore [kPa] Test pressur e [kPa] / Pressione di prova [kPa] Surrounding air temperature [°C] / Temperatura di prova [°C] Absorber temperature [°C] / Temperatura dell’assorbitore [°C] Global solar irrdiance 2 [W/m ] Failure occurred [min] --------------------------- Test conditions / Condizioni di prova Potential failure. / potenziale anomalia. Failure / Anomalia Verdict Vacuum loss ----- Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area -- Other: -- Absorber leakage Deformation such to establish permanent contact between absorber and cover Results / Risultati Duration [min] /durata -- Breaking or permanent deformation of collector fixing points or collector box Remarks / Osservazioni Verdict / Esito NOT APPLICABLE Report No. M1.11.NRG.0354/45417 Operator / Operatore Page 10 of 24 § 5.3 TAB. 2: High temperature resistance / Resistenza alle alte temperature Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... : 2011/08/10 Test installation / Installazione di Outdoor prova 2011/08/10 Indoor – solar simulator Additional information / Informazioni aggiuntive The collector has been mounted outdoors and the collector loop was filled with heat transfer fluid, since controls are used to manage both a no-flow and high temperature condition according to the manufacturer’s instructions. Such controls have been verified during the test. Il collettore è stato posizionato all’esterno ed il circuito riempito con fluido termovettore, poiché il sistema di controllo gestisce sia la condizione di assenza di flusso che la condizione di alta temperatura, secondo le istruzioni del costruttore. Durante la prova è stato verificato il funzionamento di tali controlli. The temperature of the collector was measured at the location shown below: / La temperatura del collettore è stata misurata nella posizione illustrata di seguito: Temperature sensor Additional information required if the absorber temperature was measured using a special fluid: The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to the average absorber temperature of …....….… °C Collector tilt angle [°] / tracking Inclinazione del collettore [°] 2 2 Average irradiance [W/m ] / Irraggiamento medio [W/m ] 988 Test conditions / Condizioni Average surrounding air temperature [°C] / Temperatura ambiente media [°C] 27.2 di prova Average surrounding air speed m/s] / Velocità del vento media [m/s] 0.54 Average absorber temperature [°C] / Temperatura media dell’assorbitore [°C] 82 Test duration [min] / Durata di prova [min] 62 Calculated collector stagnation temperature [°C] / 86 Temperatura di stagnazione del collettore calcolata [°C] Potential failure / Danneggiamento potenziale Failure occurred/ Verdict P Absorber leakage N/A Deformation such to establish permanent contact between absorber and cover Results / Risultati P Breaking or permanent deformation of collector fixing points or collector box Vacuum loss N/A Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area N/A P Other: Remarks / Osservazioni None Verdict / Esito PASS Report No. M1.11.NRG.0354/45417 Operator / Operatore Giovanni Bellenda Page 11 of 24 § 5.4 TAB. 3A: Exposure test / Prova di esposizione Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ............................ : 2011/07/22 Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] ............................... : 2011/09/25 Collector tilt / Inclinazione del collettore [°]: tracking Collector azimuth / angolo azimutale del collettore rispetto al sud [°]: tracking 2 32 Total days in which H > 14 MJ/m / Giorni totali con H > 14 MJ/m2: 2 Total hours with G > 850 W/m , air temperature > 10 ° C / Ore totali con G > 850 W/m2; temp. > 10 °C : 46 Remarks / Osservazioni The collector has been mounted outdoors and the collector loop was filled with heat transfer fluid, since controls are used to manage both a no-flow and high temperature condition according to the manufacturer’s instructions. All the components and subsystems, as they have been designed by the manufacturer and described in the operation manual, have been validated to be functional during the exposure period. Since the collector includes active systems to protect itself, these protections have been active and operational during the exposure test. The test cycle included the loss of electrical supply and the blockage of tracking mechanism. The collector answer and its ability to overcome such events have been checked. Il collettore è stato posizionato all’esterno ed il circuito riempito con fluido termovettore, poiché il sistema di controllo gestisce sia la condizione di assenza di flusso che la condizione di alta temperatura, secondo le istruzioni del costruttore. Tutti i componenti e i sottoassiemi, come previsti dal costruttore e descritti nel manuale di istruzioni sono stati verificati nelle loro funzionalità durante il periodo di esposizione. Poiché il collettore include sistemi attivi di protezione, tali protezioni sono state attivate e funzionanti durante il periodo di esposizione Il ciclo di prova ha incluso anche la perdita di alimentazione elettrica ed il bloccaggio del meccanismo di puntamento. Sono state verificate la risposta del sistema di controllo e la sua capacità di superare tali eventi. Operator / Operatore Report No. M1.11.NRG.0354/45417 Giovanni Bellenda Page 12 of 24 § 5.4 TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione Test start [YYYY/MM/DD] 2011/09/25 Data inizio prova [AAAA/MM/GG] Test end [YYYY/MM/DD] 2011/09/25 Data fine prova [AAAA/MM/GG] Collector fluid loop / Circuito idraulico del collettore Potential problems Evaluation* Verdict 0 0 P P P P P Evaluation* Verdict 0 P 0 P 0 P 0 P Deformation/corrosion/leakage/loss of bonding of the absorber tubes and headers / Deformazioni/corrosione/perdite/distacchi dei tubi dell’assorbitore e dei raccordi 0 P Deformation/corrosion of the absorber mountings / Deformazioni/segni di 0 P 0 P Strength / Solidità 0 P Safety / Sicurezza 0 P Loss of function / Perdita di funzionalità 0 P Safety / Sicurezza 0 P Ability to overcome the loss of power supply of the tracking mechanism / 0 P 0 P Swelling of pipes and components / Rigonfiamenti di tubature e componenti Fluid leakages / Perdite di liquidi e sgocciolamenti Cracking / Rotture Warping / Deformazioni Corrosion / Corrosione 0 0 0 Collector / Collettore Potential problems/failures Cracking/warping/corrosion/rain penetration of the collector box/fasteners Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli aggraffaggi Cracking/adhesion/elasticity of the seals/gaskets / Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni Cracking/crazing/buckling/delamination/ warping/outgassing of the cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto della copertura e/o del riflettore Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di bolle sul rivestimento dell’assorbitore corrosione dei dispositivi di montaggio e fissaggio dell’assorbitore Water retention/outgassing/degradation of the thermal insulation / Ritenzione d’acqua/perdita di vuoto/ degradazione dell’isolante termico Mounting structure / Strutture di montaggio Safety equipment / Equipaggiamento di sicurezza Capacità di superare la perdita di alimentazione elettrica del sistema di inseguimento Ability to overcome the blocking of the tracking mechanism / Capacità di superare il bloccaggio del sistema di inseguimento *Evaluation scale / Scala di valutazione: 0 - No problem / Nessun problema 1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore 2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili N/A - Inspection to establish the condition was not possible / Ispezione non possibile Remarks / Osservazioni During the power supply loss test, the backup battery has been able to drive the collector in the safe position. During the blocking of the tracking mechanism, no unsafe conditions have been detected. Durante il test di perdita dell’alimentazione elettrica, la batteria tampone è stata in condizioni di riportare il collettore in condizioni di riposo. Durante il test di motore bloccato non sono state riscontrate condizioni di pericolo. Verdict / Esito PASS Report No. M1.11.NRG.0354/45417 Operator / Operatore Giovanni Bellenda Page 13 of 24 § 5.5 TAB. 4: External thermal shock test / Prova dello shock termico esterno Test start [YYYY/MM/DD] / 2011/07/25 Data inizio prova [AAAA/MM/GG] ................ Test installation / Installazione Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] .................... : Outdoor di prova 2011/08/19 Indoor Test combined with exposure test / Test combinato con il test di esposizione Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte temperature Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova è stata effettuata su di un collettore a tubi evacuati The temperature of the collector was measured at the location shown below: / La temperatura del collettore è stata misurata nella posizione illustrata di seguito: Additional information required if the absorber temperature was measured using a special fluid: The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to the average absorber temperature of …....….… °C Shock n° 1 2 2011/07/25 2011/08/19 tracking tracking 983 977 Minimum irradiance W/m ] / Irraggiamento minimo [W/m2] 966 971 Average air temperature [°C] / 24.5 26.2 24.4 26.0 62 65 58 61 0.040 0.042 17.2 19.4 15 15 Test date / data di prova Collector tilt angle [°] / Angolo di inclinazione del collettore [°] 2 Average irradiance W/m ] / Irraggiamento medio [W/m ] 2 2 Temperatura ambiente media [°C] Test Minimum air temperature [°C] / Temperatura amb. minima [°C] conditions / Condizioni di Preconditioning period [min] / Durata di precondizionamento [min] prova Absorber temp. before spraying [°C] / Temp. dell’assorbitore prima del getto [°C] 2 Flow rate of water spray [kg/(s·m )] / Portata del getto d’acqua 2 [kg/(s•m )] Temperature of water spray [°C] / Temperatura del getto d’acqua [°C] Duration of water spray [min] / Durata del getto d’acqua [min] Potential failure. / Danno potenziale Failure occurred/ danneggiamenti occorsi Absorber leakage Deformation such to establish permanent contact between absorber and cover Results / Breaking or permanent deformation of collector fixing points or collector box Risultati Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Other: Remarks / Osservazioni : Verdict / Esito PASS Report No. M1.11.NRG.0354/45417 Operator / Operatore Giovanni Bellenda Page 14 of 24 § 5.6 TAB. 5: Internal thermal shock test / Prova dello shock termico interno Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ... : Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] ................... : -- Test installation / Installazione Indoor Outdoor di prova -- Test combined with exposure test / Test combinato con il test di esposizione Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte temperature Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova è stata effettuata su di un collettore a tubi evacuati . The temperature of the collector was measured at the location shown below: / La temperatura del collettore è stata misurata nella posizione illustrata di seguito: Additional information required if the absorber temperature was measured using a special fluid: the collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to the average absorber temperature of …....….… °C Shock n° 1 2 Test date / data di prova Test conditions / Condizioni di prova Collector tilt angle [°] / Angolo di inclinazione del collettore [°] 2 Average irradiance W/m ] / Irraggiamento medio [W/m2] 2 Minimum irradiance W/m ] / Irraggiamento minimo [W/m2] Average air temperature [°C] / Temperatura ambiente media [°C] Minimum air temperature [°C] / Temperatura amb. minima [°C] Preconditioning period [min] / Durata di precondizionamento [min] Absorber temp. before flowing [°C] / Temp. dell’assorbitore prima del flusso [°C] 2 Flow rate of heat transfer fluid [kg/(s·m )] / Portata di fluido termovettore [kg/(s•m2)] Temperature of heat transfer fluid [°C] / Temperatura del fluido termovettore [°C] Duration of flow [min] / Durata del flusso [min] Results / Risultati Potential failure / Danno potenziale Failure occurred/ danneggiamenti occorsi Absorber leakage Deformation such to establish permanent contact between absorber and cover Breaking or permanent deformation of collector fixing points or collector box Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Other: Remarks / Osservazioni : The test is not applicable to those collectors in which heat transfer fluid is continuously flowing for protection purposes. Verdict / Esito NOT APPLICABLE Report No. M1.11.NRG.0354/45417 Operator / Operatore -- Page 15 of 24 § 5.7 TAB. 6: Rain penetration test / Prova di penetrazione della pioggia Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ........... : Test installation / Installazione di Collector mounted on / Collettore Condizioni di prova Test conditions / mantenere caldo il collettore: Simulated roof / Tetto simulato Open frame/ Struttura aperta montato su: Hot water circulation / Circolazione di acqua calda Exposure of collector to solar radiation / Esposizione del collettore alla radiazione solare Collector tilt angle [°] / tracking Angolo di inclinazione del collettore [°] 2 Water flow rate [kg/(s·m )] / Portata di fluido termovettore [kg/(s•m2)] 0.045 Temperature of heat transfer fluid [°C] / 16.4 Temperatura del fluido termovettore [°C] Duration of water spray [h] / Durata del getto d’acqua [h] 4 Potential failure. / Danno potenziale Failure occurred/ danneggiamenti occorsi Results / Risultati 2011/07/29 Indoor Outdoor prova Method used to keep the absorber warm / Metodo usato per Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] ................... : 2011/07/29 Verdict Water penetration P Absorber leakage P N/A Deformation such to establish permanent contact between absorber and cover P Breaking or permanent deformation of collector fixing points or collector box Vacuum loss N/A Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area N/A P Other: Remarks / Osservazioni : Verdict / Esito Report No. M1.11.NRG.0354/45417 PASS Operator / Operatore Giovanni Bellenda Page 16 of 24 § 5.8 TAB. 7: Freeze resistance test / Prova di resistenza al gelo Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ Collector type / Tipo di collettore Antifreeze fluid (MS) / Liquido antigelo specificato dal costruttore -- Test conditions / Condizioni di -- : Data fine prova [AAAA/MM/GG] Freeze-resistant when filled with water Drain-down Water- Propylene glycol mixture / Miscela acqua-glicole propilenico Tilt angle of the collector [°] / prova Test end [YYYY/MM/DD] / Angolo di inclinazione del collettore [°] Rate of chamber cooling [K/h] / Velocità di raffreddamento [K/h] Rate of chamber heating [K/h] / Velocità di riscaldamento [K/h] Freeze conditions / Condizioni di congelamento N° of freezethaw cycle Test temperature [°C] Duration [min] Thaw conditions / Condizioni di scongelamento Test temperature [°C] Duration [min] 1 2 3 Results / Risultati Potential failure. / --. Failure occurred/ Verdict Absorber leakage Deformation such to establish permanent contact between absorber and cover Breaking or permanent deformation of collector fixing points or collector box Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Other: Remarks / Osservazioni: The manufacturer specifies the use of a water-glycol mixture for a freeze resistant use of the collector. NO TEST PERFORMED Verdict / Esito Report No. M1.11.NRG.0354/45417 PASS Operator / Operatore Giovanni Bellenda Page 17 of 24 § 5.9 TAB. 8: Mechanical load test / Prova di carico meccanico Positive pressure test of the collector cover Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ............. : 2011/08/25 Test end [YYYY/MM/DD] / Data FINE prova [AAAA/MM/GG] ................... : 2011/08/25 Loading with gravel or similar material Method used to apply positive Loading with water pressure to the cover / Metodo usato Suction cups per applicare il carico positivo alla copertura Pressurisation of collector cover 1000 Test conditions / Condizioni di prova Maximum pressure load [Pa] / Pressione di carico massima [Pa] Remarks / Note Due to the particular geometry of the collector, the procedure adopted has been the application of a static load in the worst direction against the wind load, that is in the horizontal direction. The applied load has been greater than 1000 Pa (about 200 kg) measured by means of a dynamometer. A causa della particolare geometria del collettore, la procedura adottata è stata l’applicazione di un carico statico nella direzione peggiorativa rispetto al carico di vento che risulta la direzione orizzontale. Il carico applicato è stato superiore ai 1000 Pa (circa 200 kg), misurato per mezzo di un dinamometro. Negative pressure test of fixings between the cover and collector box Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ 2011/08/25 Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] ..................... : 2011/08/25 Method used to apply negative Suction cups pressure to the cover / Metodo usato per applicare il carico negativo alla copertura Pressurisation of collector box Test conditions / Condizioni di prova Maximum pressure load [Pa] / Pressione di carico massima [Pa] Remarks / Note See above remarks 1000 Negative pressure test of collector mountings Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ................ 2011/08/25 Test end [YYYY/MM/DD] / 2011/08/25 : Data fine prova [AAAA/MM/GG] Method used to apply negative Suction cups pressure to the cover / Metodo usato per applicare il carico negativo alla copertura Air bags Test conditions / Condizioni di prova Maximum pressure load [Pa] / Pressione di carico massima [Pa] Remarks / Note See above remarks Results / Risultati 1000 Failure occurred/ Potential failure. / Danno potenziale Verdict P Absorber leakage Deformation such to establish permanent contact between absorber and cover N/A Breaking or permanent deformation of collector fixing points or collector box P N/A Vacuum loss P Other: Remarks / Osservazioni: Verdict / Esito Report No. M1.11.NRG.0354/45417 PASS Operator / Operatore Giovanni Bellenda Page 18 of 24 § 5.10 TAB. 9: Impact resistance test (optional)/ Resistenza all’impatto (opzionale) Test start [YYYY/MM/DD] / Data inizio prova [AAAA/MM/GG] ............... : -- Test end [YYYY/MM/DD] / Data fine prova [AAAA/MM/GG] ...... : -- Test installation / Installazione di prova Outdoor Indoor Collector orientation Vertical Horizontal Test method used / Metodo usato: Method 1 (steel ball) Method 2 (ice balls) -Potential failure / potenziale anomalia. Failure / Anomalia Vacuum loss Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area -- Other: -- Deformation such to establish permanent contact between absorber and cover Results / Risultati Verdict ----- Absorber leakage Breaking or permanent deformation of collector fixing points or collector box Remarks / Osservazioni Verdict / Esito Report No. M1.11.NRG.0354/45417 NOT PERFORMED Page 19 of 24 § 5.11 TAB. 10: Final inspection / Ispezione finale Test start [YYYY/MM/DD] 2011/08/25 Data inizio prova [AAAA/MM/GG] Test end [YYYY/MM/DD] 2011/08/25 Data fine prova [AAAA/MM/GG] Collector loop pipes / Tubazioni del circuito collettore Potential problems Evaluation Verdict 0 0 P P P P P 0 P Evaluation* Verdict 0 P 0 P 0 P 0 P 0 P 0 P 0 P Strength / Solidità 0 P Safety / Sicurezza 0 P Loss of function / Perdita di funzionalità 0 P Safety / Sicurezza 0 P Ability to overcome the loss of power supply of the tracking mechanism / 0 P 0 P Swelling of pipes and components / Rigonfiamenti di tubature e componenti Fluid leakages / Perdite di liquidi e sgocciolamenti Cracking / Rotture Warping / Deformazioni Corrosion / Corrosione Water retention/outgassing/degradation of the insulation / Ritenzione d’acqua / 0 0 0 Perdita del vuoto / degradazione dell’isolamento Collector / Collettore Potential problems/failures Cracking/warping/corrosion/rain penetration of the collector box/fasteners Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli aggraffaggi Cracking/adhesion/elasticity of the seals/gaskets / Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni Cracking/crazing/buckling/delamination/ warping/outgassing of the cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto della copertura e/o del riflettore Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di bolle sul rivestimento dell’assorbitore Deformation/corrosion/leakage/loss of bonding of the absorber tubes and headers / Deformazioni/corrosion/perdite/distacchi dei tubi dell’assorbitore e dei raccordi Deformation/corrosion of the absorber mountings / Deformazioni/segni di corrosion dei dispositive di montaggio e fissaggio dell’assorbitore Water retention/outgassing/degradation of the thermal insulation / Ritenzione d’acqua/perdita di vuoto/ degradazione dell’isolante termico Mounting structure / Strutture di montaggio Safety equipment / Equipaggiamento di sicurezza Capacità di superare la perdita di alimentazione elettrica del sistema di inseguimento Ability to overcome the blocking of the tracking mechanism / Capacità di superare il bloccaggio del sistema di inseguimento *Evaluation scale / Scala di valutazione: 0 - No problem / Nessun problema 1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore 2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili N/A - Inspection to establish the condition was not possible / Ispezione non possibile Remarks / Osservazioni Verdict / Esito Report No. M1.11.NRG.0354/45417 PASS Operator / Operatore Giovanni Bellenda Page 20 of 24 §6 TAB. 11A: Thermal performance – Measurements’ results / Prestazioni termiche – Risultati delle misure Test start [YYYY/MM/DD] Test method / Metodo di prova Test end [YYYY/MM/DD] 2010/11/11 Data inizio prova [AAAA/MM/GG] 6.1 Outdoor – Steady state Latitude / Latitudine: 6.1 Indoor – Steady state method 44° 52’ N Collector tilt / Inclinazione del [°] Longitude / 6.3 Outdoor – quasi-dynamic Longitudine: 08° 48’ E Tracking (-80° ÷ +80° south) Collector azimuth /Orientamento Tracking (10° ÷ 90°) collettore 2010/12/13 Data fine prova [AAAA/MM/GG] azimutale del collettore Orientation of absorber tubes during testing / Orientamento dei tubi del collettore durante la prova N/A 2 Flow rate used for performance testing (average) / Flusso utilizzato per il test (valore medio) [kg/s/m ] 0.011 Test results / Risultati di prova Data points Measured Derived # Ta [°C] G [W/m2] u [m/s] Tin [°C] Tout [°C] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1819 20 31.3 31.8 31.3 31.2 27.7 28.4 28.4 28.4 29.3 29.7 29.4 29.3 27.2 27.3 26.5 26.6 ----- 1.06 1.11 1.13 1.18 1.19 1.24 1.30 1.32 1.33 1.39 1.41 1.41 1.42 1.44 1.47 1.48 ----- 1024 1046 1018 1047 1032 1004 1012 1032 1018 1014 1024 1001 1028 1046 1045 1032 ----- 14.30 14.32 14.34 14.53 32.22 32.07 32.19 32.11 55.07 55.24 55.17 55.05 74.06 74.14 74.10 74.08 ----- 28.07 28.12 28.04 28.08 45.02 45.12 45.20 44.92 67.43 67.37 67.22 67.34 85.92 86.10 86.11 86.05 ----- Flow rate [l/min] 1.35 1.37 1.35 1.34 1.35 1.35 1.33 1.34 1.34 1.35 1.35 1.36 1.36 1.33 1.35 1.37 ----- ∆T [K] Tm [°C] Cf Q [W] Tm* ηA ηa 13.77 13.80 13.70 13.55 12.80 13.05 13.01 12.81 12.36 12.12 12.05 12.29 11.86 11.96 12.02 11.97 ----- 21.18 21.22 21.19 21.31 38.62 38.60 38.70 38.52 61.25 61.30 61.19 61.20 79.99 80.12 80.11 80.07 ----- 4.1813 4.1813 4.1813 4.1812 4.1790 4.1790 4.1790 4.1790 4.1857 4.1858 4.1857 4.1857 4.1966 4.1967 4.1967 4.1967 ----- 1295.39 1318.52 1285.15 1269.02 1198.95 1230.79 1201.81 1199.89 1158.47 1145.09 1138.74 1165.84 1125.46 1111.14 1134.23 1144.30 ----- -0.00988 -0.01011 -0.00994 -0.00945 0.01057 0.01016 0.01018 0.00980 0.03139 0.03117 0.03105 0.03185 0.05136 0.05048 0.05130 0.05182 ----- 0.63 0.63 0.63 0.61 0.58 0.61 0.59 0.58 0.57 0.56 0.56 0.58 0.55 0.53 0.54 0.55 ----- 0.63 0.63 0.63 0.61 0.58 0.61 0.59 0.58 0.57 0.56 0.56 0.58 0.55 0.53 0.54 0.55 ----- Remarks / Osservazioni The istantaneous efficiency is defined as / L’efficienza istantanea è definita come: , The second order fit to data based on the absorber area (A) is given by the equation/ La regressione lineare del secondo ordine in base all’area dell’assorbitore (A) è data dalla seguente equazione The second order fit to data based on the aperture area (a) is given by the equation/ La regressione lineare del secondo ordine in base all’area dell’apertura (a) è data dalla seguente equazione The effective thermal capacity is calculated from the measurement records of tin, ∆Τ, ta , G and by the following relation for outdoor testing / La capacità termica effettiva è calcolata dalle registrazioni misurate di tin, ∆Τ, ta , G utilizzando la seguente relazione per test all’aperto: Report No. M1.11.NRG.0354/45417 Page 21 of 24 §6 TAB. 11B: Thermal performance – Test results / Prestazioni termiche – Risultati della prova 2 Peak power (G = 1000 W/m ) – Potenza di picco (G = 1000 W/m2) 1220 [Wpeak]......................................: Power output per collector unit/ Potenza di uscita per unità di collettore G = 400 W/m^2 G = 700 W/m^2 Irradiance – Irraggiamento G = 1000 W/m^2 1400.00 Tm – Ta [K] 400 W/m 0 487.52 461.4 409.2 356.9 304.7 2 700 W/m 2 2 1000 W/m 1200.00 1000.00 10 800.00 30 600.00 50 400.00 70 200.00 853.16 826.6 774.5 722.4 670.3 1218.80 1192.7 1140.4 1088.2 1036.0 Remarks / Osservazioni: The reported values are for normal incidence 0.00 0 10 20 30 40 50 60 70 – I valori riportati si riferiscono ad incidenza normale 80 Istantaneous efficency curves / Curve di efficienza istantanea Istantaneous efficiency (APERTURE) 1.00 0.90 0.80 Efficiency 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 -0.020 -0.010 0.000 0.010 0.020 0.030 0.040 0.050 0.060 2 Reduced temperature difference (Tm - Ta)/G [K x m /W] Second order fit to data / Regressione lineare del secondo ordine Based on Absorber Area Std. Deviation Based on Aperture Area η0A η0a a1A a2A a1a a2a Std. Deviation 0.609 1.306 0 0.030 0.221 -- Time constant / Costante di tempo τc [s]: 48 -1 Effective thermal capacity / Capacità termica effettiva C [kJK ]: 10.8 Incidence angle modifier / Fattore d’angolo di incidenza Angle 0° 30° 45° 60° 65° 80° 1.20 Kθ – Longitudinal (IAM-L) 1 1 1 1 1 1 1.00 Kθ – Transversal (IAM-T) 1 1 1 1 1 1 0.80 Kθ – (IAM) 1 1 1 1 1 1 0.60 Kθb – (IAM – direct beam) -- -- -- -- -- -- 0.40 Kθd – (IAM – diffuse -- -- -- -- -- -- IAMT IAML irradiation) 0.20 0.00 0 20 40 60 Report No. M1.11.NRG.0354/45417 80 100 Kθb at 50° 1 Kθd at 50° 1 KθL at 50° 1 KθT at 50° -- Kθ at 50° 1.00 Page 22 of 24 ANNEX 1 Clause 6.2 ANNEX 1: Equipment list / Elenco degli strumenti ed attrezzature Equipment Pyranometer Temperature transmitter - INLET Temperature transmitter - OUTLET Ambient temperature sensor Anemometer Flow meter Pyrgeometer Digital data acquisition system Report No. M1.11.NRG.0354/45417 Lab. code /sn 00320 00420 00226 00186 00510 00418 00624 00532 Calibration date 27/10/2009 24/08/2009 24/08/2009 20/10/2009 20/10/2009 20/10/2009 20/10/2009 20/10/2009 Next calibration date 26/10/2011 24/08/2011 24/08/2011 20/10/2011 20/10/2011 20/10/2011 20/10/2011 20/10/2011 Page 23 of 24 ANNEX 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ANNEX 3: Schematic f the test circuit for performance tests / Schema del circuito di prova per le prove di prestazione termica Surrounding air temperature sensor Temperature sensor (te) Air vent Insulated pipe Solar collector Heater/cooler for primary temperature control Pressure gauge Safety valve Expansion tank Pump Bypass valve Flow control valve Filter (200 µm) Sight glass Flowmeter Secondary temperature regulator Artificial wind generator Temperature sensor (tin) Pyrgeometer Pyranometer Anemometer ----------------- End of Test Report No. M1.11.NRG.0354/45417 -----------------Report No. M1.11.NRG.0354/45417 Page 24 of 24