10156 TORINO (ITALY) – 21, Via Cuorgnè
Tel. +39.011.22.22.225 – Fax +39.011.22.22.226 – e-mail: [email protected] – web: www.eurofins.com
TEST REPORT
EN 12975-2: 2006: Thermal solar systems and components - Solar collectors –
Part2: Test methods
Impianti solari termici e loro componenti - Collettori solari - Parte 2: Metodi di prova
Report Reference No./ Numero rapporto .. :
M1.11.NRG.0354/45417
Date of issue / Data di emissione ................ :
2011-09-27
Total number of pages / N° tot. di pagine.... :
24
Testing Laboratory / Laboratorio di prova .. :
Eurofins – Modulo Uno S.p.A.
Address / Indirizzo .................................. :
Strada Comunale Savonesa, 9 – 15057 Rivalta Scrivia (AL) - ITALY
Applicant’s name / Nome del richiedente ... :
ZOCCHI GROUP S.r.l.
Address / Indirizzo .................................. :
Via degli Artigiani, 10 - 20010 - Buscate (MI) – ITALY
Test specification / Specifiche di prova
Standard / Norma ................................... :
Non-standard test method .................. :
EN 12975-2:2006 (+ ANNEX P - Draft Annex for prEN 12975-2 dated
2011-05-18)
N/A
Metodo di prova non standard
Scope of the test / Scopo della prova
To assess the ability to resist the influence of degrading agents and to determine the steady-state and quasidynamic thermal performance of glazed and unglazed liquid heating solar collectors, within the scope of UNI EN
12975-1:2011 “Thermal solar systems and components – Solar collectors - Part 1: General requirements”.
Verifica della capacità di un collettore solare termico per il riscaldamento di liquidi, vetrato o non vetrato, di resistere all’influenza di agenti di
degradazione e caratterizzazione delle prestazioni termiche in condizioni stazionarie e quasi dinamiche, nello scopo della norma UNI EN
12975-1: 2011: Sistemi e componenti solari termici – Collettori solari – Parte 1: Requisiti generali”.
Test item description ........................:
Descrizione dell’oggetto in prova
CONCENTRATING - Liquid heating parabolic solar collector
Collettore solare parabolico a concentrazione per il riscaldamento di liquidi
Trade Mark ......................................... :
Marchio
Manufacturer / Costruttore ....................... :
ZOCCHI GROUP S.r.l.
Address / Indirizzo .................................. :
Via degli Artigiani, 10 - 20010 - Buscate (MI) – ITALY
Model/Type reference / Modello ............. :
ZSOLEX
Date of receipt of the test item ............ :
2011/07/22
Data di ricevimento dell’oggetto in prova
Testing period / Periodo di prova ................ :
2011/07/22 ÷ 2011/09/26
This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. The test results
presented in this report relate only to the object tested. Eurofins Modulo Uno S.p.A. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia. I risultati esposti in questo rapporto di prova si
riferiscono esclusivamente all’oggetto testato. Eurofins Modulo Uno S.p.A. non assume alcuna responsabilità per danni derivanti dall’interpretazione del lettore del materiale riprodotto
al di fuori del suo contesto.
0
Ing. Giovanni Bellenda
Revision n°
Head of Renewable Energy Unit.
Summary / Sommario
GENERAL INFORMATION / INFORMAZIONI GENERALI__________________________________3
Description of test item construction / Descrizione della costruzione dell’oggetto in prova _______4
Test summary statement / Attestazione di prova_____________________________________8
Record of test sequence and summary of main results / Sequenza delle prove ______________8
TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici__9
TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici____ 10
TAB. 2: High temperature resistance / Resistenza alle alte temperature ____________________11
TAB. 3A: Exposure test / Prova di esposizione _______________________________________12
TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione _______________13
TAB. 4: External thermal shock test / Prova dello shock termico esterno ____________________14
TAB. 5: Internal thermal shock test / Prova dello shock termico interno ____________________15
TAB. 6: Rain penetration test / Prova di penetrazione della pioggia ________________________16
TAB. 7: Freeze resistance test / Prova di resistenza al gelo ______________________________17
TAB. 8: Mechanical load test / Prova di carico meccanico_______________________________18
TAB. 9: Impact resistance test (optional)/ Resistenza all’impatto (opzionale) ________________19
TAB. 10: Final inspection / Ispezione finale ________________________________________20
TAB. 11A: Thermal performance – Measurements’ results / Prestazioni termiche – Risultati delle misure
_________________________________________________________________________21
TAB. 11B: Thermal performance – Test results / Prestazioni termiche – Risultati della prova ______ 22
ANNEX 1: Equipment list / Elenco degli strumenti ed attrezzature ________________________23
ANNEX 3: Schematic f the test circuit for performance tests / Schema del circuito di prova per le prove
di prestazione termica _________________________________________________________24
Report No. M1.11.NRG.0354/45417
Page 2 of 24
GENERAL INFORMATION / INFORMAZIONI GENERALI
General remarks / Note generali:
•
This publication may be reproduced in whole or in part for non-commercial purposes as long as Eurofins
Modulo Uno S.p.A. is acknowledged as copyright owner and source of the material and only with the
written permission.
Questa pubblicazione può essere riprodotta per intero o parzialmente per scopi non commerciali a condizione che Eurofins Modulo
Uno S.p.A. sia riconoscibile come proprietaria dei diritti d’autore e fonte del materiale e solo con autorizzazione scritta.
• The test results presented in this report relate only to the object tested.
I risultati esposti in questo rapporto di prova si riferiscono esclusivamente all’oggetto testato.
• This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory.
Questo rapporto non può essere riprodotto, se non integralmente, senza l’autorizzazione scritta del laboratorio di prova che lo rilascia.
• "(see annex #)" refers to additional information include in the report.
“(vedi allegato #)” è un riferimento ad informazioni aggiuntive incluse al rapporto
• "(see tab. #)" refers to a table included in the report.
“(vedi tab.#)” è un riferimento ad una tabella annessa al rapporto
• Throughout this report a point is used as the decimal separator.
In questo rapporto di prova come separatore decimale è utilizzato il punto.
Testing location(s):
Eurofins - Modulo Uno S.p.A.
Strada Comunale Savonesa, 9
15050 Rivalta Scrivia (AL) – Italy
Sito(i) di prova
Latitude / Latitudine: 44° 52’ N
Longitude / Longitudine: 08° 48’ E
Tel. +39 011 2222225
Fax +39 011 2222226
e-mail: [email protected]
web: www.product-testing.eurofins.com
Tests performed (name of test
and test clause) ........................ :
EN 12975-2 – all applicable clauses (+ ANNEX P - Draft Annex for prEN
12975-2 dated 2011-05-18)
Prove eseguite (nome ed articolo del test)
Possible test case verdicts / Esiti di prova possibili :
- test case does not apply to the test object / il requisito non è applicabile all’oggetto in prova .......... :
N/A
- test object does meet the requirement / l’oggetto in prova rispetta il requisito .............................. :
Pass (P)
- test object does not meet the requirement / l’oggetto in prova non rispetta il requisito ................... :
Fail (F)
Abbreviations used in this report / Abbreviazioni usate in questo rapporto:
Manufacturer’s Specification / Specifica fornita dal costruttore ...................................................... :
MS
Equipment under Test / Oggetto in prova................................................................................... :
E.u.T.
Mean temperature of heat transfer fluid [°C] ..... ................................................................... :
tm
Ambient or surrounding air temperature [°C] ....... ................................................................. :
Ta or ta
-2
Global hemispherical solar irradiance [Wm ] ....................................................................... :
2
-1
G*
Reduced temperature difference ( = (tm – Ta)/G*) [m KW ].................................................. :
T*m
Zero-loss collector efficiency (η at T*m = 0), reference to T*m ............................................... :
η0
-2
-1
Heat loss coefficient [Wm K ] ............................................................................................ :
-2
-2
Temperature dependence of the heat loss coefficient [Wm K ] .......................................... :
2
Absorber area of collector [m ] .............................................................................................. :
2
Aperture area of collector [m ]............................................................................................... :
2
Gross area of collector [m ] ................................................................................................... :
-1
-1
Specific heat capacity of heat transfer fluid [Jkg K ] ........................................................... :
Report No. M1.11.NRG.0354/45417
a1
a2
AA
Aa
AG
cf
Page 3 of 24
Description of test item construction / Descrizione della costruzione dell’oggetto in prova
(Manufactories and part numbers, unless otherwise specified / Costruttori e part number, se non diversamente specificato)
Orderer / Richiedente ............................. :
ZOCCHI Group S.r.l.
Via degli Artigiani, 10 - 20010 - Buscate (MI) – Italy
Expeller / Rivenditore ............................. :
ZOCCHI Group S.r.l.
Via degli Artigiani, 10 - 20010 - Buscate (MI) – Italy
Manufacturer / Costruttore ..................... :
ZOCCHI Group S.r.l.
Via degli Artigiani, 10 - 20010 - Buscate (MI) – Italy
Sampling procedure / Procedura di
campionamento........................................ :
Random sampling from production / Campionamento casuale dalla
produzione
Prototype submitted by client / Prototipo fornito dal cliente
Brand name / Nome commerciale ............ :
ZSOLEX
Serial number / Numero di serie .............. :
000002
Lab. identification codes / Codici
identificativi del laboratorio .......................... :
10.0632
Photograph(s) of the E.u.T. / Foto dell’oggetto in prova
Report No. M1.11.NRG.0354/45417
Page 4 of 24
Ratings / Dati tecnici nominali
Max working temperature [°C] /
Massima temperatura operativa [°C]
............................ :
Max working pressure [bar] / Massima pressione operativa [bar] .................................. :
2
Rated (recommended) flow rate [l/m h] / Portata nominale (consigliata) [l/m2h] ............. :
250
6
30
Collector / Collettore
Manufacturer / Costruttore ............................ :
ZOCCHI Group S.r.l.
Model / Modello ........................................... :
ZSOLEX
Glazed flat plate / Vetrato piano
Vacuum tube – Heat pipe single glass tube / Tubi evacuati – Tubo di calore singola copertura vetrata
Vacuum tube – Heat pipe double glass tube / Tubo di calore doppia copertura vetrata
Collector type / Tipo
di collettore ................ :
Vacuum tube – U Tube / Tubi evacuati – Tubi a U
Vacuum tube – filled with water / Tubi evacuati riempiti d’acqua
Without covering – unglazed / Scoperto - non vetrato
Other / Altro :
concentrazione
Tracking parabolic single point concentrator / collettore solare parabolico puntuale a
Serial product / Prodotto di serie ............................................................................. :
YES / SÌ
Drawing number / N° di disegno ............................................................................ :
--
Serial number / Numero di serie ............................................................................. :
000002
Date when manufactured / data di costruzione ........................................................
2010
Collector loop flow range [kg/s] / Campo di flusso del circuito collettore [kg/s] ................... :
0.005 ÷ 0.04
Operating pressure [kPa] / Pressione di esercizio ..................................................... :
--
NO
2
Stagnation temperature at 1000 W/m and 30°C ambient temperature [°C] /
Temperatura di stagnazione a 1000 W/m2 e 30°C di temperature ambiente [°C] ................................ :
Collector mounting / Montaggio del collettore ............................................................ :
-on metal support with tracking
system / su supporti metallic con sistema
di inseguimento
Support metal frame material (if any) Materiale del supporto metallico
N° of collectors /
N° di collettori
(se esistente)
........ :
............................................................................. :
Gross length [mm] / Lunghezza lorda [mm] ............................................................... :
Gross width [mm] / Larghezza lorda [mm] ................................................................. :
Gross height [mm] / Altezza lorda [mm] ................................................................... :
2
Gross area [m ] / Superficie lorda [m2]:
2
Aperture area [m ] / Superficie di apertura [m2]:
2
Iron - steel
1
1600 (Parabolic concentarator
diameter /Diametro del concentratore
parabolico)
1600 (Parabolic concentarator
diameter /Diametro del concentratore
parabolico)
1700 (including stand and and
gear box / compresi supporti e gruppo
motorizzato):
2.10
2.00
Absorber area [m ] / Superficie assorbitore [m2]:
0.03
Weight empty [kg] / Peso a vuoto [kg]:
56
Report No. M1.11.NRG.0354/45417
Page 5 of 24
Weight without glazing [kg] / Peso senza copertura vetrata [kg]
--
Fluid capacity [l] / Capacità di contenimento di fluido [l]
4
Number of covers / Numero di coperture
--
Cover material / Materiale copertura
--
Cover thickness [mm] / Spessore copertura [mm]
--
Cover solar transmittance [%] / Trasmittanza solare della copertura [%] .......................... :
--
Absorber material / Materiale assorbitore :
Aluminum / Alluminio
Absorber’s dimensions / Dimensioni dell’assorbitore ................................................... :
Cylindrical tank - Length 303
mm, ext. diameter 150 mm /
Recipiente cilindrico - Lunghezza 303 mm,
diametro esterno 150 mm
Absorber’s thickness [mm] / Spessore dell’assorbitore [mm] ........................................
--
Absorber dry weight [kg] / Peso a vuoto dell’assorbitore [kg] ......................................... :
2
Absorber – Fin width [mm] / Larghezza alette dell’assorbitore [mm] ................................ :
--
Absorber – Fin thickness [mm] / Spessore alette dell’assorbitore [mm] ........................... :
--
Solar absorptance α / Fattore di assorbimento solare α ............................................... :
--
Hemispherical emittance ε / Emittanza emisferica ε .................................................. :
--
Surface treatment / Trattamento superficiale.............................................................. :
--
Construction type / Tipo di costruzione
.............................................................. :
--
Number of risers / Numero di tubi di innalzamento ........................................................ :
--
Riser diameter or dimensions / Dimensioni o diametro dei tubi di innalzamento .................. :
--
Distance between risers / Distanza tra i tubi di innalzamento ......................................... :
--
Back thermal insulation thickness / Spessore dell’isolamento termico posteriore ............... :
25
Side thermal insulation thickness / Spessore dell’isolamento termico laterale................... :
25
Insulation material / Materiale isolante
Rockwool
.............................................................. :
Casing material / Materiale di contenimento .............................................................. :
--
Sealing material / Materiale di sigillatura
.............................................................. :
--
Other limitations / Altre limitazioni
.............................................................. :
--
Report No. M1.11.NRG.0354/45417
Page 6 of 24
Comments on collector design / Commenti sul progetto del collettore ............................ :
Heat transfer medium / Mezzo termovettore ............................................................ :
None / Nessuno
Water- glycol mixture / Miscela
acqua-glicole
Alternative acceptable heat transfer
None / nessuno
fluids / Fluido termovettore alternative accettabile :
Test item particulars: / Particolari dell’oggetto in prova:
The collector is mounted on a motorized structure driven by a control unit suitable both to track the sun and to
implement the safety functions required. / Il collettore è montato su di una struttura metallica motorizzata pilotata da una unità elettronica adatta
a realizzare la funzione di inseguimento del sole e ad implementare le funzioni di sicurezza richieste
Accessories and detachable parts included in the evaluation / Accessori e parti
separabili incluse nella valutazione.................................................................................. :
--
Options included / Opzioni incluse ......................................................................... :
Sketch of the collector / Schema del collettore
Schematic diagram of the absorber / Diagramma
schematico dell’assorbitore
Component list / Distinta dei componenti
Item / Componente
Supplier / Fornitore
Item code / Codice
Notes-material / Note - materiale
componente
Parabolic concentrator
Concentratore parabolico
Absorber
Assorbitore
Manifold tubes
Tubi collettore
Absorber tubes
Tubi assorbitore
Collector insulation
Isolante collettore
Collector back sheet
Fondo collettore
Absorber mounting
structure
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Struttura di supporto
dell’assorbitore
Tape sealant
Sigillante a nastro
Report No. M1.11.NRG.0354/45417
Page 7 of 24
Test summary statement / Attestazione di prova
The product tested as described on page 1 through 7 complies with the requirements of the
nd
standard(s) mentioned on page 1, as detailed below. The measurements were carried out from 22
th
July 2011 to 25 September 2011. No problems or relevant observations occurred during the
measurements.
Il prodotto testato, come descritto nelle pagine da 1 a 7, rispetta i requisiti della(e) norma(e) citata (e) a pagina 1, come
dettagliato nel seguito. Le misure sono state effettuate dal 22 luglio 2011 al 25 settembre 2011. Durante le misure non è stato
evidenziato nessun problema né rilievo significativo.
Record of test sequence and summary of main results / Sequenza delle prove
Clause
Date / Data
Clause
EN 129751
EN 129752
5.3.2
5.2
5.3.3
5.3
Test / Prova
Results –
remarks /
Risultati -note
VERDICT
2011/07/29
(see Tab.
1A)
P
2011/08/10
2011/08/10
(see Tab. 2)
P
2011/07/22
2011/09/25
(see Tab. 3)
P
(see Tab. 4)
P
(see Tab. 5)
N/A
Start /
End /
Inizio
Fine
2011/07/29
Internal pressure for absorbers /
Pressione interna degli assorbitori
High temperature resistance /
Resistenza alle alte temperature
5.3.4
5.4
Exposure test /
Prova di esposizione
5.3.5
5.3.6
5.5
5.6
5.3.7
5.7
5.3.10
5.8
5.3.8
5.9
4.1.7
5.10
--
5.11
5.3.9
6
External thermal shock /
First
2011/07/25
2011/07/25
Prova dello shock termico
esterno
Second
2011/08/19
2011/08/19
Internal thermal shock /
First
Prova dello shock termico
interno
Second
Rain penetration test /
2011/07/29
2011/07/29
(see Tab. 6)
P
--
--
(see Tab. 7)
P
2011/08/25
2011/08/25
(see Tab. 8)
N/A
--
--
Not
performed
(see Tab. 9)
--
2011/09/25
2011/09/25
(see Tab. 10)
P
2011/07/22
2011/09/25
See/vedi Tab.
11
--
Prova di penetrazione della pioggia
Freeze resistance test /
Prova di resistenza al gelo
Mechanical load test/
Prova di carico meccanico
Impact resistance test (optional)/
Prova di resistenza all’impatto (opzionale)
Dismantling final inspection /
Ispezione finale di smontaggio
Thermal performance testing /
Prova delle prestazioni termiche
Report No. M1.11.NRG.0354/45417
Page 8 of 24
§ 5.2
TAB. 1A: Internal pressure for inorganic absorbers / Pressione interna degli assorbitori inorganici
Test start
[YYYY/MM/DD] /
2011/07/22
Data inizio prova [AAAA/MM/GG]
Test installation /
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ....................
Outdoor
Installazione di prova
:
2011/07/22
Indoor
Maximum allowed working pressure MS [kPa] / Massima pressione di esercizio ammessa specificata dal
400
costruttore [kPa]
Test ambient temperature [°C] /
Test conditions /
Condizioni di prova
26.5
Temperatura ambiente di prova [°C]
600
Test pressure [kPa] / Pressione di prova [kPa]
15
Test duration [min] / Durata di prova [min]
Results / Risultati
Failure
occurred/
Potential failure / --.
Verdict
Absorber leakage
P
Deformation such to establish permanent contact between absorber and
cover
P
Breaking or permanent deformation of collector fixing points or collector
box
P
N/A
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the
transparent cover of the collector exceeding 10% of the aperture area
P
Other:
P
Remarks / Osservazioni:
None
Verdict / Esito
PASS
Report No. M1.11.NRG.0354/45417
Operator /
Operatore
Enrico Martino
Page 9 of 24
§ 5.2
TAB. 1B: Internal pressure for organic absorbers / Pressione interna degli assorbitori organici
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ...............
--
Test installation / Installazione
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ....................
Outdoor
di prova
--
Indoor
Method used to pressurize the absorber / Metodo usato per pressurizzare il collettore:
Pneumatic
Hydraulic
Method used to keep the
absorber warm / Metodo usato
Solar simulator
Natural sunlight
Heated water bath
Heated pressurized
circuit
per mantenere caldo il collettore:
Maximum allowed working pressure MS [kPa] / Massima pressione di esercizio specificata dal costruttore [kPa]
Test
pressur
e [kPa] /
Pressione
di prova
[kPa]
Surrounding air
temperature [°C] /
Temperatura di prova [°C]
Absorber
temperature
[°C] /
Temperatura
dell’assorbitore
[°C]
Global solar
irrdiance
2
[W/m ]
Failure occurred
[min]
---------------------------
Test conditions /
Condizioni di prova
Potential failure. / potenziale anomalia.
Failure / Anomalia
Verdict
Vacuum loss
-----
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
--
Other:
--
Absorber leakage
Deformation such to establish permanent contact between absorber and cover
Results / Risultati
Duration
[min] /durata
--
Breaking or permanent deformation of collector fixing points or collector box
Remarks / Osservazioni
Verdict / Esito
NOT APPLICABLE
Report No. M1.11.NRG.0354/45417
Operator /
Operatore
Page 10 of 24
§ 5.3
TAB. 2: High temperature resistance / Resistenza alle alte temperature
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] .................... :
2011/08/10
Test installation / Installazione di
Outdoor
prova
2011/08/10
Indoor – solar simulator
Additional information / Informazioni aggiuntive
The collector has been mounted outdoors and the collector loop was filled with heat transfer fluid, since
controls are used to manage both a no-flow and high temperature condition according to the manufacturer’s
instructions. Such controls have been verified during the test.
Il collettore è stato posizionato all’esterno ed il circuito riempito con fluido termovettore, poiché il sistema di controllo gestisce sia la condizione di assenza
di flusso che la condizione di alta temperatura, secondo le istruzioni del costruttore. Durante la prova è stato verificato il funzionamento di tali controlli.
The temperature of the collector was measured at the location shown below: / La temperatura del collettore è stata
misurata nella posizione illustrata di seguito:
Temperature
sensor
Additional information required if the absorber temperature was measured using a special fluid:
The collector was partially filled with ………….. and the average pressure was …………. Pa, which corresponds to
the average absorber temperature of …....….… °C
Collector tilt angle [°] /
tracking
Inclinazione del collettore [°]
2
2
Average irradiance [W/m ] / Irraggiamento medio [W/m ]
988
Test conditions / Condizioni
Average surrounding air temperature [°C] / Temperatura ambiente media [°C]
27.2
di prova
Average surrounding air speed m/s] / Velocità del vento media [m/s]
0.54
Average absorber temperature [°C] / Temperatura media dell’assorbitore [°C]
82
Test duration [min] / Durata di prova [min]
62
Calculated collector stagnation temperature [°C] /
86
Temperatura di stagnazione del collettore calcolata [°C]
Potential failure / Danneggiamento potenziale
Failure
occurred/
Verdict
P
Absorber leakage
N/A
Deformation such to establish permanent contact between absorber and cover
Results /
Risultati
P
Breaking or permanent deformation of collector fixing points or collector box
Vacuum loss
N/A
Accumulation of humidity in form of condensate on the inside of the transparent cover
of the collector exceeding 10% of the aperture area
N/A
P
Other:
Remarks / Osservazioni
None
Verdict / Esito
PASS
Report No. M1.11.NRG.0354/45417
Operator /
Operatore
Giovanni Bellenda
Page 11 of 24
§ 5.4
TAB. 3A: Exposure test / Prova di esposizione
Test start [YYYY/MM/DD] / Data inizio
prova [AAAA/MM/GG] ............................ :
2011/07/22
Test end [YYYY/MM/DD] / Data fine
prova [AAAA/MM/GG] ............................... :
2011/09/25
Collector tilt / Inclinazione del collettore [°]:
tracking
Collector azimuth / angolo azimutale del collettore rispetto al sud [°]:
tracking
2
32
Total days in which H > 14 MJ/m / Giorni totali con H > 14 MJ/m2:
2
Total hours with G > 850 W/m , air temperature > 10 ° C / Ore totali con G > 850 W/m2; temp. > 10 °C :
46
Remarks / Osservazioni
The collector has been mounted outdoors and the collector loop was filled with heat transfer fluid, since controls
are used to manage both a no-flow and high temperature condition according to the manufacturer’s instructions.
All the components and subsystems, as they have been designed by the manufacturer and described in the
operation manual, have been validated to be functional during the exposure period. Since the collector includes
active systems to protect itself, these protections have been active and operational during the exposure test.
The test cycle included the loss of electrical supply and the blockage of tracking mechanism. The collector
answer and its ability to overcome such events have been checked.
Il collettore è stato posizionato all’esterno ed il circuito riempito con fluido termovettore, poiché il sistema di controllo gestisce sia la condizione di assenza di
flusso che la condizione di alta temperatura, secondo le istruzioni del costruttore. Tutti i componenti e i sottoassiemi, come previsti dal costruttore e descritti nel
manuale di istruzioni sono stati verificati nelle loro funzionalità durante il periodo di esposizione. Poiché il collettore include sistemi attivi di protezione, tali
protezioni sono state attivate e funzionanti durante il periodo di esposizione
Il ciclo di prova ha incluso anche la perdita di alimentazione elettrica ed il bloccaggio del meccanismo di puntamento. Sono state verificate la risposta del
sistema di controllo e la sua capacità di superare tali eventi.
Operator /
Operatore
Report No. M1.11.NRG.0354/45417
Giovanni Bellenda
Page 12 of 24
§ 5.4
TAB. 3B: Inspection after exposure test/ Ispezione dopo il test di esposizione
Test start [YYYY/MM/DD]
2011/09/25
Data inizio prova [AAAA/MM/GG]
Test end [YYYY/MM/DD]
2011/09/25
Data fine prova [AAAA/MM/GG]
Collector fluid loop / Circuito idraulico del collettore
Potential problems
Evaluation*
Verdict
0
0
P
P
P
P
P
Evaluation*
Verdict
0
P
0
P
0
P
0
P
Deformation/corrosion/leakage/loss of bonding of the absorber tubes and
headers / Deformazioni/corrosione/perdite/distacchi dei tubi dell’assorbitore e dei raccordi
0
P
Deformation/corrosion of the absorber mountings / Deformazioni/segni di
0
P
0
P
Strength / Solidità
0
P
Safety / Sicurezza
0
P
Loss of function / Perdita di funzionalità
0
P
Safety / Sicurezza
0
P
Ability to overcome the loss of power supply of the tracking mechanism /
0
P
0
P
Swelling of pipes and components / Rigonfiamenti di tubature e componenti
Fluid leakages / Perdite di liquidi e sgocciolamenti
Cracking / Rotture
Warping / Deformazioni
Corrosion / Corrosione
0
0
0
Collector / Collettore
Potential problems/failures
Cracking/warping/corrosion/rain penetration of the collector box/fasteners
Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli
aggraffaggi
Cracking/adhesion/elasticity of the seals/gaskets /
Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni
Cracking/crazing/buckling/delamination/ warping/outgassing of the
cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto
della copertura e/o del riflettore
Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di
bolle sul rivestimento dell’assorbitore
corrosione dei dispositivi di montaggio e fissaggio dell’assorbitore
Water retention/outgassing/degradation of the thermal insulation / Ritenzione
d’acqua/perdita di vuoto/ degradazione dell’isolante termico
Mounting structure / Strutture di montaggio
Safety equipment / Equipaggiamento di sicurezza
Capacità di superare la perdita di alimentazione elettrica del sistema di inseguimento
Ability to overcome the blocking of the tracking mechanism / Capacità di
superare il bloccaggio del sistema di inseguimento
*Evaluation scale / Scala di valutazione:
0 - No problem / Nessun problema
1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore
2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili
N/A - Inspection to establish the condition was not possible / Ispezione non possibile
Remarks / Osservazioni
During the power supply loss test, the backup battery has been able to drive the collector in the safe position.
During the blocking of the tracking mechanism, no unsafe conditions have been detected.
Durante il test di perdita dell’alimentazione elettrica, la batteria tampone è stata in condizioni di riportare il collettore in condizioni di riposo.
Durante il test di motore bloccato non sono state riscontrate condizioni di pericolo.
Verdict / Esito
PASS
Report No. M1.11.NRG.0354/45417
Operator /
Operatore
Giovanni Bellenda
Page 13 of 24
§ 5.5
TAB. 4: External thermal shock test / Prova dello shock termico esterno
Test start [YYYY/MM/DD] /
2011/07/25
Data inizio prova [AAAA/MM/GG] ................
Test installation / Installazione
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] .................... :
Outdoor
di prova
2011/08/19
Indoor
Test combined with exposure test / Test combinato con il test di esposizione
Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte
temperature
Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova
è stata effettuata su di un collettore a tubi evacuati
The temperature of the collector was measured at the location shown below: / La
temperatura del collettore è stata misurata nella posizione illustrata di seguito:
Additional information required if the absorber temperature was measured using a special
fluid:
The collector was partially filled with ………….. and the average pressure was ………….
Pa, which corresponds to the average absorber temperature of …....….… °C
Shock n°
1
2
2011/07/25
2011/08/19
tracking
tracking
983
977
Minimum irradiance W/m ] / Irraggiamento minimo [W/m2]
966
971
Average air temperature [°C] /
24.5
26.2
24.4
26.0
62
65
58
61
0.040
0.042
17.2
19.4
15
15
Test date / data di prova
Collector tilt angle [°] /
Angolo di inclinazione del collettore [°]
2
Average irradiance W/m ] / Irraggiamento medio [W/m ]
2
2
Temperatura ambiente media [°C]
Test
Minimum air temperature [°C] / Temperatura amb. minima [°C]
conditions
/ Condizioni di Preconditioning period [min] / Durata di precondizionamento [min]
prova
Absorber temp. before spraying [°C] / Temp. dell’assorbitore prima del
getto [°C]
2
Flow rate of water spray [kg/(s·m )] / Portata del getto d’acqua
2
[kg/(s•m )]
Temperature of water spray [°C] /
Temperatura del getto d’acqua [°C]
Duration of water spray [min] / Durata del getto d’acqua [min]
Potential failure. / Danno potenziale
Failure occurred/ danneggiamenti occorsi
Absorber leakage
Deformation such to establish permanent contact between absorber and cover
Results /
Breaking or permanent deformation of collector fixing points or collector box
Risultati
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the
transparent cover of the collector exceeding 10% of the aperture area
Other:
Remarks / Osservazioni :
Verdict / Esito
PASS
Report No. M1.11.NRG.0354/45417
Operator /
Operatore
Giovanni Bellenda
Page 14 of 24
§ 5.6
TAB. 5: Internal thermal shock test / Prova dello shock termico interno
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ... :
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ................... :
--
Test installation / Installazione
Indoor
Outdoor
di prova
--
Test combined with exposure test / Test combinato con il test di esposizione
Test combined with high temperature resistance test / Test combinato con il test di resistenza alle alte
temperature
Additional information if an evacuated tubular collector was tested / Informazioni aggiuntive se la prova
è stata effettuata su di un collettore a tubi evacuati . The temperature of the collector was measured at the
location shown below: / La temperatura del collettore è stata misurata nella posizione illustrata di seguito:
Additional information required if the absorber temperature was measured using a special
fluid: the collector was partially filled with ………….. and the average pressure was
…………. Pa, which corresponds to the average absorber temperature of …....….… °C
Shock n°
1
2
Test date / data di prova
Test conditions / Condizioni di prova
Collector tilt angle [°] /
Angolo di inclinazione del collettore [°]
2
Average irradiance W/m ] / Irraggiamento medio [W/m2]
2
Minimum irradiance W/m ] / Irraggiamento minimo [W/m2]
Average air temperature [°C] /
Temperatura ambiente media [°C]
Minimum air temperature [°C] /
Temperatura amb. minima [°C]
Preconditioning period [min] / Durata di precondizionamento [min]
Absorber temp. before flowing [°C] /
Temp. dell’assorbitore prima del flusso
[°C]
2
Flow rate of heat transfer fluid [kg/(s·m )] / Portata di fluido termovettore
[kg/(s•m2)]
Temperature of heat transfer fluid [°C] /
Temperatura del fluido termovettore
[°C]
Duration of flow [min] / Durata del flusso [min]
Results / Risultati
Potential failure / Danno potenziale
Failure occurred/ danneggiamenti occorsi
Absorber leakage
Deformation such to establish permanent contact between absorber and cover
Breaking or permanent deformation of collector fixing points or collector box
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
Other:
Remarks / Osservazioni :
The test is not applicable to those collectors in which heat transfer fluid is continuously flowing for protection purposes.
Verdict / Esito
NOT APPLICABLE
Report No. M1.11.NRG.0354/45417
Operator /
Operatore
--
Page 15 of 24
§ 5.7
TAB. 6: Rain penetration test / Prova di penetrazione della pioggia
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ........... :
Test installation / Installazione di
Collector mounted on / Collettore
Condizioni di prova
Test conditions /
mantenere caldo il collettore:
Simulated roof / Tetto simulato
Open frame/ Struttura aperta
montato su:
Hot water circulation / Circolazione di acqua calda
Exposure of collector to solar radiation / Esposizione del collettore
alla radiazione solare
Collector tilt angle [°] /
tracking
Angolo di inclinazione del collettore [°]
2
Water flow rate [kg/(s·m )] / Portata di fluido termovettore [kg/(s•m2)]
0.045
Temperature of heat transfer fluid [°C] /
16.4
Temperatura del fluido termovettore [°C]
Duration of water spray [h] / Durata del getto d’acqua [h]
4
Potential failure. / Danno potenziale
Failure occurred/
danneggiamenti
occorsi
Results / Risultati
2011/07/29
Indoor
Outdoor
prova
Method used to keep the
absorber warm / Metodo usato per
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ................... :
2011/07/29
Verdict
Water penetration
P
Absorber leakage
P
N/A
Deformation such to establish permanent contact between absorber and cover
P
Breaking or permanent deformation of collector fixing points or collector box
Vacuum loss
N/A
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
N/A
P
Other:
Remarks / Osservazioni :
Verdict / Esito
Report No. M1.11.NRG.0354/45417
PASS
Operator /
Operatore
Giovanni Bellenda
Page 16 of 24
§ 5.8
TAB. 7: Freeze resistance test / Prova di resistenza al gelo
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................
Collector type / Tipo di collettore
Antifreeze fluid (MS) / Liquido
antigelo specificato dal costruttore
--
Test conditions / Condizioni di
--
:
Data fine prova [AAAA/MM/GG]
Freeze-resistant when filled with water
Drain-down
Water- Propylene glycol mixture / Miscela acqua-glicole propilenico
Tilt angle of the collector [°] /
prova
Test end [YYYY/MM/DD] /
Angolo di inclinazione del collettore [°]
Rate of chamber cooling [K/h] / Velocità di raffreddamento [K/h]
Rate of chamber heating [K/h] / Velocità di riscaldamento [K/h]
Freeze conditions / Condizioni di congelamento
N° of freezethaw cycle
Test
temperature [°C]
Duration [min]
Thaw conditions
/ Condizioni di scongelamento
Test temperature [°C]
Duration [min]
1
2
3
Results / Risultati
Potential failure. / --.
Failure
occurred/
Verdict
Absorber leakage
Deformation such to establish permanent contact between absorber and cover
Breaking or permanent deformation of collector fixing points or collector box
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
Other:
Remarks / Osservazioni:
The manufacturer specifies the use of a water-glycol mixture for a freeze resistant use of the collector.
NO TEST PERFORMED
Verdict / Esito
Report No. M1.11.NRG.0354/45417
PASS
Operator /
Operatore
Giovanni Bellenda
Page 17 of 24
§ 5.9
TAB. 8: Mechanical load test / Prova di carico meccanico
Positive pressure test of the collector cover
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ............. :
2011/08/25
Test end [YYYY/MM/DD] /
Data FINE prova [AAAA/MM/GG] ................... :
2011/08/25
Loading with gravel or similar material
Method used to apply positive
Loading with water
pressure to the cover / Metodo usato
Suction cups
per applicare il carico positivo alla copertura
Pressurisation of collector cover
1000
Test conditions / Condizioni di prova
Maximum pressure load [Pa] / Pressione di carico massima [Pa]
Remarks / Note
Due to the particular geometry of the collector, the procedure adopted has
been the application of a static load in the worst direction against the wind
load, that is in the horizontal direction. The applied load has been greater
than 1000 Pa (about 200 kg) measured by means of a dynamometer.
A causa della particolare geometria del collettore, la procedura adottata è stata l’applicazione di
un carico statico nella direzione peggiorativa rispetto al carico di vento che risulta la direzione
orizzontale. Il carico applicato è stato superiore ai 1000 Pa (circa 200 kg), misurato per mezzo
di un dinamometro.
Negative pressure test of fixings between the cover and collector box
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................
2011/08/25
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ..................... :
2011/08/25
Method used to apply negative
Suction cups
pressure to the cover / Metodo usato
per applicare il carico negativo alla copertura
Pressurisation of collector box
Test conditions / Condizioni di prova
Maximum pressure load [Pa] / Pressione di carico massima [Pa]
Remarks / Note
See above remarks
1000
Negative pressure test of collector mountings
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ................
2011/08/25
Test end [YYYY/MM/DD] /
2011/08/25
:
Data fine prova [AAAA/MM/GG]
Method used to apply negative
Suction cups
pressure to the cover / Metodo usato
per applicare il carico negativo alla copertura
Air bags
Test conditions / Condizioni di prova
Maximum pressure load [Pa] / Pressione di carico massima [Pa]
Remarks / Note
See above remarks
Results / Risultati
1000
Failure
occurred/
Potential failure. / Danno potenziale
Verdict
P
Absorber leakage
Deformation such to establish permanent contact
between absorber and cover
N/A
Breaking or permanent deformation of collector fixing
points or collector box
P
N/A
Vacuum loss
P
Other:
Remarks / Osservazioni:
Verdict / Esito
Report No. M1.11.NRG.0354/45417
PASS
Operator /
Operatore
Giovanni Bellenda
Page 18 of 24
§ 5.10
TAB. 9: Impact resistance test (optional)/ Resistenza all’impatto (opzionale)
Test start [YYYY/MM/DD] /
Data inizio prova [AAAA/MM/GG] ............... :
--
Test end [YYYY/MM/DD] /
Data fine prova [AAAA/MM/GG] ...... :
--
Test installation / Installazione di prova
Outdoor
Indoor
Collector orientation
Vertical
Horizontal
Test method used / Metodo usato:
Method 1 (steel ball)
Method 2 (ice balls)
-Potential failure / potenziale anomalia.
Failure / Anomalia
Vacuum loss
Accumulation of humidity in form of condensate on the inside of the transparent
cover of the collector exceeding 10% of the aperture area
--
Other:
--
Deformation such to establish permanent contact between absorber and cover
Results / Risultati
Verdict
-----
Absorber leakage
Breaking or permanent deformation of collector fixing points or collector box
Remarks / Osservazioni
Verdict / Esito
Report No. M1.11.NRG.0354/45417
NOT PERFORMED
Page 19 of 24
§ 5.11
TAB. 10: Final inspection / Ispezione finale
Test start [YYYY/MM/DD]
2011/08/25
Data inizio prova [AAAA/MM/GG]
Test end [YYYY/MM/DD]
2011/08/25
Data fine prova [AAAA/MM/GG]
Collector loop pipes / Tubazioni del circuito collettore
Potential problems
Evaluation
Verdict
0
0
P
P
P
P
P
0
P
Evaluation*
Verdict
0
P
0
P
0
P
0
P
0
P
0
P
0
P
Strength / Solidità
0
P
Safety / Sicurezza
0
P
Loss of function / Perdita di funzionalità
0
P
Safety / Sicurezza
0
P
Ability to overcome the loss of power supply of the tracking mechanism /
0
P
0
P
Swelling of pipes and components / Rigonfiamenti di tubature e componenti
Fluid leakages / Perdite di liquidi e sgocciolamenti
Cracking / Rotture
Warping / Deformazioni
Corrosion / Corrosione
Water retention/outgassing/degradation of the insulation / Ritenzione d’acqua /
0
0
0
Perdita del vuoto / degradazione dell’isolamento
Collector / Collettore
Potential problems/failures
Cracking/warping/corrosion/rain penetration of the collector box/fasteners
Rotture/deformazioni/corrosione/penetrazione di pioggia nella scatola del collettore e/o negli
aggraffaggi
Cracking/adhesion/elasticity of the seals/gaskets /
Rottura/incollamento/elasticizzazione dei sigillanti e/o delle guarnizioni
Cracking/crazing/buckling/delamination/ warping/outgassing of the
cover/reflector / Rotture/formazione di crepe/crolli/delaminazioni/deformazioni/perdite di vuoto
della copertura e/o del riflettore
Cracking/crazing/blistering of the absorber coating / Rotture/crepe/formazioni di
bolle sul rivestimento dell’assorbitore
Deformation/corrosion/leakage/loss of bonding of the absorber tubes and
headers / Deformazioni/corrosion/perdite/distacchi dei tubi dell’assorbitore e dei raccordi
Deformation/corrosion of the absorber mountings / Deformazioni/segni di corrosion
dei dispositive di montaggio e fissaggio dell’assorbitore
Water retention/outgassing/degradation of the thermal insulation / Ritenzione
d’acqua/perdita di vuoto/ degradazione dell’isolante termico
Mounting structure / Strutture di montaggio
Safety equipment / Equipaggiamento di sicurezza
Capacità di superare la perdita di alimentazione elettrica del sistema di inseguimento
Ability to overcome the blocking of the tracking mechanism / Capacità di
superare il bloccaggio del sistema di inseguimento
*Evaluation scale / Scala di valutazione:
0 - No problem / Nessun problema
1 - Requirement apart from testing not fulfilled (minor failure) / Problema di entità minore
2 - Requirements for testing not fulfilled (major failure) / Problemi non trascurabili
N/A - Inspection to establish the condition was not possible / Ispezione non possibile
Remarks / Osservazioni
Verdict / Esito
Report No. M1.11.NRG.0354/45417
PASS
Operator /
Operatore
Giovanni Bellenda
Page 20 of 24
§6
TAB. 11A: Thermal performance – Measurements’ results / Prestazioni termiche – Risultati delle misure
Test start [YYYY/MM/DD]
Test method / Metodo di prova
Test end [YYYY/MM/DD]
2010/11/11
Data inizio prova [AAAA/MM/GG]
6.1 Outdoor – Steady state
Latitude / Latitudine:
6.1 Indoor – Steady state method
44° 52’ N
Collector tilt / Inclinazione del
[°]
Longitude /
6.3 Outdoor – quasi-dynamic
Longitudine:
08° 48’ E
Tracking (-80° ÷ +80°
south)
Collector azimuth /Orientamento
Tracking (10° ÷ 90°)
collettore
2010/12/13
Data fine prova [AAAA/MM/GG]
azimutale del collettore
Orientation of absorber tubes during testing / Orientamento dei tubi del collettore durante la prova
N/A
2
Flow rate used for performance testing (average) / Flusso utilizzato per il test (valore medio) [kg/s/m ]
0.011
Test results / Risultati di prova
Data points
Measured
Derived
#
Ta
[°C]
G
[W/m2]
u
[m/s]
Tin
[°C]
Tout
[°C]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1819
20
31.3
31.8
31.3
31.2
27.7
28.4
28.4
28.4
29.3
29.7
29.4
29.3
27.2
27.3
26.5
26.6
-----
1.06
1.11
1.13
1.18
1.19
1.24
1.30
1.32
1.33
1.39
1.41
1.41
1.42
1.44
1.47
1.48
-----
1024
1046
1018
1047
1032
1004
1012
1032
1018
1014
1024
1001
1028
1046
1045
1032
-----
14.30
14.32
14.34
14.53
32.22
32.07
32.19
32.11
55.07
55.24
55.17
55.05
74.06
74.14
74.10
74.08
-----
28.07
28.12
28.04
28.08
45.02
45.12
45.20
44.92
67.43
67.37
67.22
67.34
85.92
86.10
86.11
86.05
-----
Flow
rate
[l/min]
1.35
1.37
1.35
1.34
1.35
1.35
1.33
1.34
1.34
1.35
1.35
1.36
1.36
1.33
1.35
1.37
-----
∆T
[K]
Tm
[°C]
Cf
Q
[W]
Tm*
ηA
ηa
13.77
13.80
13.70
13.55
12.80
13.05
13.01
12.81
12.36
12.12
12.05
12.29
11.86
11.96
12.02
11.97
-----
21.18
21.22
21.19
21.31
38.62
38.60
38.70
38.52
61.25
61.30
61.19
61.20
79.99
80.12
80.11
80.07
-----
4.1813
4.1813
4.1813
4.1812
4.1790
4.1790
4.1790
4.1790
4.1857
4.1858
4.1857
4.1857
4.1966
4.1967
4.1967
4.1967
-----
1295.39
1318.52
1285.15
1269.02
1198.95
1230.79
1201.81
1199.89
1158.47
1145.09
1138.74
1165.84
1125.46
1111.14
1134.23
1144.30
-----
-0.00988
-0.01011
-0.00994
-0.00945
0.01057
0.01016
0.01018
0.00980
0.03139
0.03117
0.03105
0.03185
0.05136
0.05048
0.05130
0.05182
-----
0.63
0.63
0.63
0.61
0.58
0.61
0.59
0.58
0.57
0.56
0.56
0.58
0.55
0.53
0.54
0.55
-----
0.63
0.63
0.63
0.61
0.58
0.61
0.59
0.58
0.57
0.56
0.56
0.58
0.55
0.53
0.54
0.55
-----
Remarks / Osservazioni
The istantaneous efficiency is defined as / L’efficienza
istantanea è definita come:
,
The second order fit to data based on the absorber area (A)
is given by the equation/ La regressione lineare del secondo ordine
in base all’area dell’assorbitore (A) è data dalla seguente equazione
The second order fit to data based on the aperture area (a)
is given by the equation/ La regressione lineare del secondo ordine
in base all’area dell’apertura (a) è data dalla seguente equazione
The effective thermal capacity is calculated from the
measurement records of tin, ∆Τ, ta , G and by the following
relation for outdoor testing / La capacità termica effettiva è
calcolata dalle registrazioni misurate di tin, ∆Τ, ta , G utilizzando la
seguente relazione per test all’aperto:
Report No. M1.11.NRG.0354/45417
Page 21 of 24
§6
TAB. 11B: Thermal performance – Test results / Prestazioni termiche – Risultati della prova
2
Peak power (G = 1000 W/m ) – Potenza di picco (G = 1000 W/m2)
1220
[Wpeak]......................................:
Power output per collector unit/ Potenza di uscita per unità di collettore
G = 400 W/m^2
G = 700 W/m^2
Irradiance – Irraggiamento
G = 1000 W/m^2
1400.00
Tm – Ta [K]
400 W/m
0
487.52
461.4
409.2
356.9
304.7
2
700 W/m
2
2
1000 W/m
1200.00
1000.00
10
800.00
30
600.00
50
400.00
70
200.00
853.16
826.6
774.5
722.4
670.3
1218.80
1192.7
1140.4
1088.2
1036.0
Remarks / Osservazioni: The reported values are for normal incidence
0.00
0
10
20
30
40
50
60
70
– I valori riportati si riferiscono ad incidenza normale
80
Istantaneous efficency curves / Curve di efficienza istantanea
Istantaneous efficiency (APERTURE)
1.00
0.90
0.80
Efficiency
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
-0.020
-0.010
0.000
0.010
0.020
0.030
0.040
0.050
0.060
2
Reduced temperature difference (Tm - Ta)/G [K x m /W]
Second order fit to data / Regressione lineare del secondo ordine
Based on Absorber Area
Std. Deviation
Based on Aperture Area
η0A
η0a
a1A
a2A
a1a
a2a
Std. Deviation
0.609
1.306
0
0.030
0.221
--
Time constant / Costante di tempo τc [s]:
48
-1
Effective thermal capacity / Capacità termica effettiva C [kJK ]:
10.8
Incidence angle modifier / Fattore d’angolo di incidenza
Angle
0°
30°
45°
60°
65°
80°
1.20
Kθ – Longitudinal (IAM-L)
1
1
1
1
1
1
1.00
Kθ – Transversal (IAM-T)
1
1
1
1
1
1
0.80
Kθ – (IAM)
1
1
1
1
1
1
0.60
Kθb – (IAM – direct beam)
--
--
--
--
--
--
0.40
Kθd – (IAM – diffuse
--
--
--
--
--
--
IAMT
IAML
irradiation)
0.20
0.00
0
20
40
60
Report No. M1.11.NRG.0354/45417
80
100
Kθb at 50°
1
Kθd at 50°
1
KθL at 50°
1
KθT at 50°
--
Kθ at 50°
1.00
Page 22 of 24
ANNEX 1
Clause
6.2
ANNEX 1: Equipment list / Elenco degli strumenti ed attrezzature
Equipment
Pyranometer
Temperature transmitter - INLET
Temperature transmitter - OUTLET
Ambient temperature sensor
Anemometer
Flow meter
Pyrgeometer
Digital data acquisition system
Report No. M1.11.NRG.0354/45417
Lab. code /sn
00320
00420
00226
00186
00510
00418
00624
00532
Calibration date
27/10/2009
24/08/2009
24/08/2009
20/10/2009
20/10/2009
20/10/2009
20/10/2009
20/10/2009
Next calibration date
26/10/2011
24/08/2011
24/08/2011
20/10/2011
20/10/2011
20/10/2011
20/10/2011
20/10/2011
Page 23 of 24
ANNEX 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
ANNEX 3: Schematic f the test circuit for performance tests / Schema del circuito di prova per
le prove di prestazione termica
Surrounding air temperature sensor
Temperature sensor (te)
Air vent
Insulated pipe
Solar collector
Heater/cooler for primary temperature control
Pressure gauge
Safety valve
Expansion tank
Pump
Bypass valve
Flow control valve
Filter (200 µm)
Sight glass
Flowmeter
Secondary temperature regulator
Artificial wind generator
Temperature sensor (tin)
Pyrgeometer
Pyranometer
Anemometer
----------------- End of Test Report No. M1.11.NRG.0354/45417 -----------------Report No. M1.11.NRG.0354/45417
Page 24 of 24