Cattura il sole e trasformalo in energia sempre disponibile per la tua casa! DELIOS s.r.l. - Riva dell’Ospedale, 14 - 35013 Cittadella (PD) Sede Operativa: Via S. Antonio, 16 - Loc. Belvedere - 36056 Tezze sul Brenta (VI) Tel. +39 0424 561758 - Fax. +39 0424 861220 [email protected] - www.delios-srl.it Input (PV) Max. DC power Max. DC voltage PV-voltage range, MPPT PV-voltage range, MPPT - Indipendent Operation PV-voltage range, MPPT - Parallel Operation DC nominal voltage Max DC power x MPPT Max DC power x MPPT - Unbalanced operation Min. DC voltage Max. input current x MPPT Number of MPP trackers (DLS I-Track) Max. number of strings (parallel) Battery (BATT) Battery type Battery voltage range Battery current Depth of Discharge Charging management (Lead Acid) Short circuit protection Battery temperature compensation Battery voltage sense Current shunt Input (AC GRID) AC input voltage AC input frequency AC connection AC overload & short-circuit protection PV/BATT/GEN SET to AC commutation time (NORMAL OPERATION) PV/BATT/GEN SET to AC commutation time (BACKUP MODE) Input (AC GEN SET) (***) AC input voltage AC input frequency AC connection AC overload & short-circuit protection GEN SET enable contact (NO - programmable) Output (AC) Nominal AC power - Continuos (PV + BATT) Nominal AC power - Continuos (BATT) Max. AC power - Peak Nominal output current (RMS) Peak output current Crest Factor AC output voltage AC output frequency THD AC connection System Operating Mode OFF GRID operation ON GRID operation BACKUP MODE operation Home appliance & external device remote control Programmable home appliance control contacts Auxiliary signalling & control contacts Efficiency (PV – AC output) Max. efficiency Euro-eta Efficiency (BATT – AC output) Max. efficiency Protection devices PV DC reverse polarity protection PV DC load-disconnecting switch Pb-Acid BATT DC overload protection (INTERNAL FUSE) Pb-Acid BATT DC load-disconnecting switch (EXTERNAL) AC input overload & short-circuit protection AC output short-circuit protection AC safety interlock system (CEI 0-21 installation requirement) Manual AC GRID BY-PASS switch Ground fault monitoring Grid monitoring & synchronization BATT DC Galvanically isolated Integrated RCMU (Residual Current Monitoring Unit) General Data Dimensions (W / H / D) in mm Weight Operating temperature range Power derating temperature range Storage temperature range Relative humidity range Acoustic noise emmission Enviromental pollution degree Ingress protection class Installation Protection class Overvoltage category (IEC 62109-1) Stand-by Consumption Topology PV-AC Topology BATT-AC Cooling concept Features PV DC connection DC BAT connection AC connection Graphic display touch screen Interfaces: CAN/ USB/ Ethernet / WiFi Warranty: 5 / 10 / 15 / 20 / 25 years Certificates Product standards National connection standards Legenda: u Standard feature u Optional feature *** Under request – Not available DLS-300 DLS-450 DLS-600 3.1kW 600V 100V - 550V 100V - 550V @ 2kW 100V - 550V @ 3.1kW 400V 2kW 2kW @ MPPT1 + 1.1kW @ MPPT2 115V 10A 2 1+1 4.7kW 600V 100V - 550V 100V - 550V @ 3kW 100V - 550V @ 4.7kW 400V 3kW 3kW @ MPPT1 + 1.7kW @ MPPT2 115V 15A 2 2+2 6.3kW 600V 100V - 550V 100V - 550V @ 4kW 100V - 550V @ 6.3kW 400V 4kW 4kW @ MPPT1 + 2.3kW @ MPPT2 115V 20A 2 2+2 Lead Acid or LI-Ion (***) 40V - 60V 5A - 60A, programmable 0 - 80%, programmable 3-stage adaptative with maintenance Electronic, @ max charging current, switch off < 1sec Lead Acid or LI-Ion (***) 40V - 60V 5A - 60A, programmable 0 - 80%, programmable 3-stage adaptative with maintenance Electronic, @ max charging current, switch off < 1sec Lead Acid or LI-Ion (***) 40V - 60V 5A - 100A, programmable 0 - 80%, programmable 3-stage adaptative with maintenance Electronic, @ max charging current, switch off < 1sec 230Vac ± 15% 50/60Hz 1 ph Miniature Circuit Breaker 0s < 0.5s 230Vac ± 15% 50/60Hz 1 ph Miniature Circuit Breaker 0s < 0.5s 230Vac ± 15% 50/60Hz 1 ph Miniature Circuit Breaker 0s < 0.5s 230Vac ± 15% 50/60Hz 1 ph Miniature Circuit Breaker 230Vac ± 15% 50/60Hz 1 ph Miniature Circuit Breaker 230Vac ± 15% 50/60Hz 1 ph Miniature Circuit Breaker 3kVA 3kVA 1.5 x Pnom (10sec) - 1.2 x Pnom (30sec) 13A 60A 4.6 230Vac ± 2% 50/60Hz ± 0.2% < 3% 1 ph 4.5kVA 3kVA 1.5 x Pnom (10sec) - 1.2 x Pnom (30sec) 19.6A 80A 4.1 230Vac ± 2% 50/60Hz ± 0.2% < 3% 1 ph 6kVA 4.5kVA 1.5 x Pnom (10sec) - 1.2 x Pnom (30sec) 26.1A 80A 3.1 230Vac ± 2% 50/60Hz ± 0.2% < 3% 1 ph default setting selectable selectable default setting selectable selectable default setting selectable selectable 4 contacts - NO 2 contacts - NO 4 contacts - NO 2 contacts - NO 4 contacts - NO 2 contacts - NO 97% 96% 97% 96% 97% 96% 94% 94% 94% u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u 710 / 650 / 150 < 20kg -25°C…+60°C 40°C…+60°C -30°C…+70°C 5%...95% - Not condensing < 37 dB(A) @ 1m PD 3 IP 21 Indoors - Unconditioned I II (DC input) III (AC output) < 4W Transformless HF transformer I-cool (Fan on demand) 710 / 650 / 150 < 25kg -25°C…+60°C 40°C…+60°C -30°C…+70°C 5%...95% - Not condensing < 37 dB(A) @ 1m PD 3 IP 21 Indoors - Unconditioned I II (DC input) III (AC output) < 4W Transformless HF transformer I-cool (Fan on demand) 710 / 650 / 150 < 25kg -25°C…+60°C 40°C…+60°C -30°C…+70°C 5%...95% - Not condensing < 37 dB(A) @ 1m PD 3 IP 21 Indoors - Unconditioned I II (DC input) III (AC output) < 4W Transformless HF transformer I-cool (Fan on demand) MC4 quick connector screw terminal block screw terminal block u u / u /u / u u / u /u / u CE IEC 62109-1 (Safety) IEC 62109-2 (Safety) IEC 61000-6-1 (EMC) IEC 61000-6-3 (EMC) CEI 0-21 (IT) MC4 quick connector screw terminal block screw terminal block u u / u /u / u u / u /u / u CE IEC 62109-1 (Safety) IEC 62109-2 (Safety) IEC 61000-6-1 (EMC) IEC 61000-6-3 (EMC) CEI 0-21 (IT) MC4 quick connector screw terminal block screw terminal block u u / u /u / u u / u /u / u CE IEC 62109-1 (Safety) IEC 62109-2 (Safety) IEC 61000-6-1 (EMC) IEC 61000-6-3 (EMC) CEI 0-21 (IT) (*) Delios S.r.l. si riserva il diritto di modificare prodotti e dati tecnici in qualsiasi momento e senza alcun preavviso