REGIONE PIEMONTE PROVINCIA DI CUNEO COMUNI DI LESEGNO E SAN MICHELE MONDOVI' IMPIANTO IDROELETTRICO SU TRAVERSA ESISTENTE DEL TORRENTE CORSAGLIA Località "La Gatta" Documentazione ai sensi del Regolamento regionale 10/R del 29 luglio 2003 Valutazione di Impatto Ambientale ex artt. 6 d.lgs.152/06 e s.m.i. e 4 L.R. 40/98 e s.m.i., RELAZIONE TECNICA DATA PROGETTO Ottobre 2014 SCALA Elaborato 2 GRUPPO DI PROGETTAZIONE RICHIEDENTI OLIVERO ENERGIA STUDIO DI INGEGNERIA Dott. Ing. ANTONIO CAPELLINO Via Rosa Bianca, 18 12084 Mondovì - (CN) 0174/551247 [email protected] [email protected] di Olivero Piero Osvaldo Via Cesare Vinaj, 2 12100 - Cuneo (CN) P.IVA. 00762070043 PEC Dott. Arch. DANIELE BORGNA Via G. Pascoli, 39/6 - 12084 Mondovì (CN) 339-3131477 [email protected] Dott. Ing. ALBERTO BONELLO Strada di Pascomonti - 12084 Mondovì (CN) 328-4541205 [email protected] Geom. ALBERTO BALSAMO S.S. 28 Nord, 81 - 12084 Mondovì (CN) 347-4097196 [email protected] Si riservano tutti i diritti di divulgazione e/o riproduzione del presente documento senza specifica autorizzazione ai sensi della legge 24.04.41 n.633 e s.m. ed int. Relazione tecnica SOMMARIO 1. PREMESSA E MOTIVAZIONE A SOTTOPORRE IL PROGETTO A FASE DI VALUTAZIONE DI IMPATTO AMBIENTALE.................................................................................................................... 3 2. QUADRO PROGRAMMATICO E NORMATIVO ......................................................................... 6 2.1. Introduzione ...................................................................................................................... 6 2.2. Inquadramento normativo .................................................................................................. 6 2.3. Vincoli territoriali e ambientali ............................................................................................ 9 3. INQUADRAMENTO PROGRAMMATICO .................................................................................12 3.1.1. Il Piano Territoriale Regionale – PTR........................................................................12 3.1.2. Il Piano Paesaggistico Regionale (P.P.R.) ................................................................15 3.1.3. Piano Territoriale di Coordinamento della Provincia di Cuneo ...................................16 3.1.4. Piani sull’ambiente idrico: P.A.I., P.D.R.I. e P.T.A. ....................................................17 3.1.5. Piani Regolatori Generali Comuni interessati dall’intervento (P.R.G.C.) ....................21 3.1.6. Programmazione in materia di “energia” ...................................................................29 4. MOTIVAZIONI ALLA BASE DELLA SCELTA PROGETTUALE .................................................31 5. ELENCO ELABORATI ..............................................................................................................32 6. COORDINATE UTM DELL’IMPIANTO ......................................................................................33 7. SCELTA PROGETTUALE E IPOTESI PROGETTUALI ALTERNATIVE ....................................33 7.1. Analisi delle alternative progettuali e scelta della soluzione in esame ................................33 7.2. Soluzione alternativa A .....................................................................................................33 7.3. Soluzioni alternative B ......................................................................................................35 7.4. Soluzione adottata............................................................................................................37 8. DESCRIZIONE GENERALE DELL’IMPIANTO ..........................................................................38 9. CONSIDERAZIONI CIRCA IL BACINO ATTUALE E QUELLO CON INTERVENTO ..................41 10. SINTESI IDROLOGICA ............................................................................................................43 10.1. Portate medie ...................................................................................................................44 10.2. Curva di durata delle portate.............................................................................................45 10.3. Portate derivabili...............................................................................................................46 11. TRAVERSA FLUVIALE ESISTENTE ........................................................................................54 12. INTERVENTI DI ADEGUAMENTO DELLA TRAVERSA ............................................................55 13. CENTRALE IDROELETTRICA PRINCIPALE ............................................................................58 13.1. Opera di presa ed adduzione............................................................................................58 13.2. Edificio e meccanismi di produzione .................................................................................60 13.3. Canale di restituzione .......................................................................................................60 14. CENTRALE DI RILASCIO E VALORIZZAZIONE ENERGETICA DEL DMV ..............................61 15. LOCALE DI CONSEGNA ENEL................................................................................................63 16. GESTIONE DELLA PORTATA .................................................................................................65 16.1. Dispositivi di modulazione della portata ............................................................................65 16.2. Dispositivo di limitazione della portata derivata .................................................................67 16.3. Dispositivi di misura della portata......................................................................................67 16.4. Dispositivi di controllo visivo e di misura diretta delle portate derivata e rilasciata ..............68 16.5. Dispositivo di evidenziazione delle portate ........................................................................68 16.6. Ripartizione della portata ..................................................................................................69 16.7. Gestione della derivazione irrigua del Consorzio San Gervasio.........................................71 16.8. Distribuzione della portata derivabile tra le turbine idrauliche ............................................71 16.9. Passaggio artificiale per l’ittiofauna ...................................................................................75 16.9.1. Verifica delle fenditure..............................................................................................75 16.9.2. Verifica della velocità nei passaggi ...........................................................................76 16.9.3. Verifica della dissipazione di energia ........................................................................76 16.9.4. Verifica dello stramazzo Bazin per il controllo della portata .......................................77 17. SALTO IDRAULICO .................................................................................................................78 17.1. Quota idrometrica a monte ...............................................................................................78 17.1.1. Metodo di calcolo .....................................................................................................78 17.1.2. Turbina principale ....................................................................................................79 17.1.3. Turbina di rilascio del deflusso minimo vitale ............................................................81 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 1 Relazione tecnica 17.2. Quota idrometrica a valle ..................................................................................................82 17.3. Salto idraulico...................................................................................................................84 17.3.1. Turbina principale ....................................................................................................84 17.3.2. Turbina di rilascio del deflusso minimo vitale ............................................................85 18. PRODUZIONE..........................................................................................................................86 18.1. Impianto principale ...........................................................................................................87 18.2. Impianto di rilascio e valorizzazione energetica del DMV ..................................................89 18.3. Impianto complessivo .......................................................................................................91 19. SCELTA DELLE TURBINE E POTENZE INSTALLATE E NOMINALI........................................94 19.1. Scelta delle turbine da installare .......................................................................................94 19.2. Salto idraulico medio ........................................................................................................95 19.3. Potenza dell'impianto e delle turbine.................................................................................96 19.3.1. Potenza nominale ....................................................................................................96 19.3.2. Potenza installata.....................................................................................................96 20. ACCESSIBILITÀ E ORGANIZZAZIONE DI CANTIERE .............................................................97 21. ATTESTAZIONE DI CREDITO .................................................................................................98 22. VERIFICHE IDRAULICHE DEL TORRENTE CORSAGLIA .......................................................99 23. ANALISI DEL TRASPORTO SOLIDO .....................................................................................100 23.1. Metodo di calcolo ...........................................................................................................100 23.2. Portata di massima piena centennale .............................................................................101 23.3. Portata media annua ......................................................................................................102 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 2 Relazione tecnica 1. PREMESSA E MOTIVAZIONE A SOTTOPORRE IL PROGETTO A FASE DI VALUTAZIONE DI IMPATTO AMBIENTALE Il presente progetto riguarda la costruzione di un IMPIANTO IDROELETTRICO SU TRAVERSA ESISTENTE DEL TORRENTE CORSAGLIA in località "La Gatta" in Comune di Lesegno. L’impianto idroelettrico previsto, di nuova realizzazione, si sviluppa in un tratto terminale del Torrente Corsaglia, circa 7,5 km prima della confluenza con il Fiume Tanaro. L’opera sfrutta una traversa esistente, utilizzata per la derivazione irrigua del Consorzio San Gervasio, posta a ridosso del confine comunale tra il Comune di Lesegno, in sponda destra orografica e quello di San Michele Mondovì in sponda sinistra. Il progetto prevede due gruppi di produzione, uno principale posto in sponda destra orografica e uno secondario volto alla valorizzazione del DMV, posto nel corpo della traversa. L’impianto è classificabile in funzione delle proprie caratteristiche nei seguenti modi: mini impianto (100 kW ≤ P < 1˙000 kW) : l’impianto idroelettrico progettato ha una potenza nominale massima di 656 kW e media di 284 kW; le due turbine hanno potenza complessiva installata di 578 kW e nell’anno idrologico medio producono circa 2,1 GWh di energia elettrica; - impianto ad acqua fluente: l’impianto idroelettrico progettato non possiede capacità d’invaso, se non per i piccoli volumi d’acqua contenuti nelle varie opere idrauliche che compongono la centrale, che non possono essere sfruttate in modo proficuo per la modulazione della portata; - impianto a bassa caduta (H < 50 m) : l'impianto idroelettrico in progetto nell'anno idrologico medio valorizza energeticamente il salto medio di 4,95 m; - impianto a media portata (10 m3/s ≤ Q < 100 m3/s) : l’impianto idroelettrico progettato valorizza portate comprese tra 0,600 m3/s e 14,000 m3/s, la centrale nel suo complesso ( impianto principale e turbina recupero DMV ) deriva annualmente la portata media di 5,851 m3/s. Il progetto si basa su un rilievo topografico dettagliato, eseguito con stazione totale, con la registrazione di circa 700 punti, che ha permesso di studiare con precisione il comportamento idraulico del tratto di asta interessata oltre che localizzazione migliore delle altre opere ingegneristiche e idrauliche. Le caratteristiche tecniche e costruttive proposte in questa fase progettuale sono il frutto di una collaborazione fra studi professionali che hanno lavorato in modo sinergico al fine di definire soluzioni tecniche che conciliano l’esigenza di una razionale utilizzazione idroelettrica delle acque del Torrente Corsaglia con le esigenze di salvaguardia ambientale e tutela dell’asta fluviale. L’impianto in progetto, non disponendo di capacità di invaso degli afflussi, deriva soltanto una parte della portata presente nel corso d'acqua; nel brevissimo tratto sotteso di torrente Corsaglia è garantito il deflusso di una quota della portata sempre superiore al deflusso minimo vitale (DMV), anche in periodi di magra se disponibile da monte. Quindi nell’impianto in progetto le macchine idrauliche ed elettriche producono con modi e tempi totalmente dipendenti dalla disponibilità idrica del corso d'acqua; nel caso in cui il corso d'acqua sia in magra e si scenda sotto un livello minimo di portata, cessa la produzione di energia elettrica. Il presente progetto è stato realizzato in stretto contatto con il proponente, la ditta OLIVERO ENERGIE, impresa individuale, di Olivero Piero Osvaldo con sede in Cuneo, che, fin dalle prime fasi di impostazione dello studio, ha manifestato la volontà di realizzare un’opera in armonia col territorio e con le esigenze sociali e produttive dei Comuni di Lesegno e San Michele M.vì. Il progetto idroelettrico è stato sottoposto alla fase di Verifica Ambientale ai sensi della L.R. 40/98 art.10 con istanza del 06/06/2014. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 3 Relazione tecnica La Provincia di Cuneo Settore Gestione del Territorio – Ufficio Valutazione Impatto Ambientale in data 08/09/2014 comunicava al proponente l’esito del procedimento della Verifica di Impatto Ambientale. L’esito del procedimento relativo al progetto idroelettrico in sintesi riportava : • 1) di Escluderlo dalla Procedura di Valutazione di Impatto Ambientale in quanto dall’istruttoria tecnica è emerso che l’attuazione dell’intervento, che interessa una traversa irrigua già esistente in un contesto naturale di fondovalle e sottende un corso d’acqua assai breve, non determinerà significative né rilevanti modifiche sulle componenti ambientali interferite, in termini sia di alterazione dello stato attuale dei luoghi sia di apprezzabili interferenze a carico del torrente Corsaglia, rispetto a quelle già presenti ante operam. ………. • 2) Di subordinare l’esclusione di cui al precedente punto 1) al rispetto delle seguenti prescrizioni, finalizzate all’ottimizzazione del progetto dal punto di vista ambientale: a) Per ridurre gli attendibili impatti di tipo idromorfologico, deve essere eliminato lo sbarramento mobile gonfiabile e realizzato solo l’impianto principale, rinunciando alla sopraelevazione della traversa ………. b) il Deflusso Minimo Vitale deve essere preservato dall’utilizzo energetico …… In particolare i punti 1 e 2 riportavano le relative motivazioni, seguivano successivamente una serie di richieste di integrazioni. Il proponente Olivero Energia S.r.l. ritiene di sottoporre il Progetto di Derivazione alla Fase di Valutazione di Impatto Ambientale ai sensi della L.R. 40/98 art.12 e ex art.6 D. Lgs 152/2006. La motivazione della scelta del Proponente, pur nel rispetto dell’Esito del Procedimento da parte dell’Organo Tecnico Provinciale, si basa sul risultato della fase di verifica, in cui sono stati riscontrati dei potenziali impatti di carattere ambientale che devono essere sviluppati in modo specifico all'interno di un procedimento di Valutazione di Impatto Ambientale. Inoltre il progetto senza la valorizzazione energetica del D.M.V. e senza l’innalzamento della traversa con sbarramento mobile si configura come un progetto totalmente diverso da quello proposto. Il progetto presentato ha infatti la peculiarità di utilizzare e valorizzare pienamente una traversa esistente, con una buona producibilità senza dover realizzare alcun tratto sotteso. L’invaso esiste già, la traversa esistente produce comunque un bacino, il progetto prevede di incrementarlo di soli circa 350 metri, in quanto a monte il profilo dell'alveo del torrente sale in maniera significativa e ne riduce l’estensione. Il proponente ha fatto redigere uno studio specialistico sulla caratterizzazione delle componenti biotiche e abiotiche dell’ecosistema acquatico del torrente Corsaglia nell’ambito del progetto relativo all’intervento proposto e una conseguente valutazione degli impatti. In particolare lo studio allegato nella presente documentazione tecnica, elaborato n° 28, illustra e presenta i risultati delle attività di caratterizzazione dell’ecosistema acquatico nel torrente Corsaglia nell'ambito del progetto di derivazione idroelettrica sulla traversa esistente in località “la Gatta”. Tale attività si pone come obiettivo quello di qualificare lo stato biotico e abiotico del torrente nei tratti di progetto potenzialmente interessati dalla derivazione al fine di: valutare gli impatti su di esso; individuare opportune misure di mitigazione; valutare la compatibilità del progetto con gli obiettivi definiti dal PdGPo anche alla luce dello condizioni attuali e sito specifiche. Si sono eseguiti pertanto rilievi a carico delle seguenti componenti biotiche e abiotiche: parametri chimico-fisici, per una valutazione dello stato chimico del corpo idrico a supporto di quello ecologico; macroinvertebrati, per la definizione dello stato ecologico attuale del corso d’acqua e per una verifica del mantenimento degli obiettivi di qualità ecologica fissati ed esplicitati con la predisposizione del Piano di Gestione del Distretto Idrografico del fiume Po; fauna ittica, per una valutazione della comunità ittica presente nel tratto anche al fine di individuare le specie target da impiegare per la progettazione della scala di risalita; astacidi, al fine di ricercare l’eventuale presenza della specie nostrana, Austropotamobius pallipes, potenzialmente presente secondo quanto indicato dagli Organi provinciali. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 4 Relazione tecnica La qualità fluviale del tratto per quel che attiene le componenti dei macro-invertebrati e dei parametri chimico-fisici si attesta su buoni ed elevati valori. In considerazione delle caratteristiche dell’impianto, non si prevedono modificazioni di questa situazione. Il tratto corrispondente alla traversa di derivazione, non è idoneo a popolamento stabile di fauna ittica. Nel tratto immediatamente a valle la fauna ittica è caratterizzata prevalentemente da ciprinidi reofili con anche specie ad abitudini bentoniche, così come il tratto di monte. Non si prevedono interferenze indotte dalla presenza della centrale di produzione e dall’inserimento del gonfiabile. A monte l’aumento della colonna d’acqua potrebbe addirittura favorire gli stadi giovanili di alcune specie che troverebbero, con l’ulteriore proliferazione delle macrofite acquatiche, determinata dalla maggiore profondità che si creerebbe con l’inserimento del gonfiabile, altri siti di rifugio. Da segnalare il rinvenimento delle lampreda, specie di pregio e protetta, per la quale il presente progetto ha predisposto una specifica misura: un passaggio specie-specifico, al fine di consentire alle popolazioni di valle più numerose di portarsi a monte e ampliare il proprio areale di distribuzione e la propria consistenza demografica. È prevista la realizzazione di un altro passaggio per pesci realizzato in sponda idrografica destra a monte dell’opera di restituzione, che assicurerà una continuità al corso d’acqua e rappresenterà un vantaggio per le specie che necessitano di migrazioni a fini trofici o riproduttivi, come il barbo canino poco presente nel tratto e impossibilitato a portarsi più a monte dove troverebbe certamente condizioni migliori per l’automantenimento. Le conclusioni dello studio riportano che l’impatto sulle componenti ambiente idrico e fauna ittica può essere quindi ragionevolmente stimato in basso. Circa la valorizzazione energetica del DMV attraverso l’impianto nel corpo traversa, anche alla luce degli studi e dei monitoraggi effettuati di recente, si espone quanto segue, pur nel rispetto dell’esito della Verifica Ambientale. La soluzione, con rimozione dell’impianto in corpo traversa, preferibile dal punto di vista ambientale da parte del Comitato Tecnico, indicata da codesto Ufficio, sulla base del contenuto della Verifica di Impatto Ambientale non trova, alla luce degli studi successivamente eseguiti dal proponente, conferma da caratteri ambientali specifici, ma segue un indirizzo, non codificato, che da qualche tempo viene applicato, ritenendo il DMV un fattore imprescindibile di non utilizzabilità. In realtà, occorre sempre ricondursi alla “ratio” normativa, che prevede, giustamente, che un corso d’acqua non venga sfruttato integralmente a discapito delle diverse componenti ambientali coinvolte (pesci, qualità delle acque, presenze bentonitiche, vegetazione spondale o igrofila). Questo concetto, è sempre vero se viene sotteso un tratto di corso d’acqua. Se l’intervento è puntuale, come quello in progetto, nessuna di queste componenti viene intaccata o alterata. Di qui, il legislatore (Regione Piemonte Reg. Regionale 10/R del 2003, e Reg. Regionale 1/R del 2014) ha inteso, non solo derogare, ma favorire questi interventi puntuali, a discapito di altri che prevedono sottensioni. Anzi, si ammette in modo specifico, l’utilizzo del DMV per interventi puntuali sul corpo traversa. La stessa normativa nazionale del GSE, intende favorire, rilasciando titolo di prelazione, gli interventi che risultano puntuali su traversa, senza tratto sotteso. Nella fattispecie, visto il contesto ambientale, l’inserimento nel corpo traversa di un manufatto che utilizza l’energia potenziale è quanto di meglio si possa auspicare con riguardo dell’impatto sull’ambiente con matrice di valutazione solo positiva. Ad esempio la Regione Lombardia (che rientra pienamente nel territorio di competenza AdiBPo), con Legge Regionale n°5 del febbraio 2010, addirittura, riconoscendo la mancanza di elementi di impatto ambientale sugli impianti puntuali su corpo traversa, (e con recupero del DMV) ha addirittura escluso tali impianti dalle procedure di verifica e di VIA. Tutto ciò considerato si ritiene che la soluzione proposta (con valorizzazione energetica del DMV e sbarramento mobile sulla traversa esistente) sia da ritenersi preferibile rispetto alle altre soluzioni, adottate anche sullo stesso corso d’acqua a monte e a valle, dove vi è un significativo tratto sotteso del T. Corsaglia. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 5 Relazione tecnica 2. QUADRO PROGRAMMATICO E NORMATIVO 2.1. Introduzione Il progetto dell’opera in oggetto sarà sottoposto alla procedura di Valutazione di Impatto Ambientale, ex artt. 6 d.lgs.152/06 e s.m.i. e 4 L.R. 40/98 e s.m.i. e documentazione ai sensi del Regolamento regionale 10/R del 29 luglio 2003. 2.2. Inquadramento normativo Per quanto riguarda la realizzazione dell'opera in progetto e la presenza di vincoli sull'area, sono stati verificati gli adempimenti normativi dettati dalle seguenti disposizioni di legge: - Regio Decreto 30 dicembre 1923, n. 3267 - Riordino e riforma della legislazione in materia di boschi e di terreni montani. Titolo I, Capo I, Sezione 1: Vincolo per scopi idrogeologici; - Legge 29 giugno 1939, n. 1497 - Protezione delle bellezze naturali; - Decreto legislativo 27 giugno 1985, n. 312 - Disposizione urgenti per la tutela delle zone di particolare interesse ambientale; - Legge 8 agosto 1985, n. 431 - Conversione in legge, con modificazioni, del D.L. 312/85; - Legge 28 gennaio 1977, n. 10 - Norme per la edificabilità dei suoli. Art.4: rilascio della concessione edilizia; - Legge Regionale 5 dicembre 1977, n.56 – Tutela ed uso del suolo; - Legge regionale 3 aprile 1989, n. 20 - Norme in materia di beni culturali, ambientali e paesistici; - Legge Regionale 9 agosto 1989, n. 45 - Nuove norme per gli i interventi da eseguire in terreni sottoposti a vincolo per scopi idrogeologici - Abrogazione della L.R. 12 agosto 1981, n. 27; - Circolare del Presidente della Giunta Regionale del 31 gennaio 1990 - Circolare esplicativa sull'applicazione della L.R. 9 agosto 1989, n. 45; - Legge Regionale 10 novembre 1994, n.45 - Norme in materia di pianificazione del territorio: modifiche alla L.R. 5 dicembre 1977, n. 56 e successive modifiche ed integrazioni e alle LL.RR. 16 marzo 1989, n. 16 e 3 aprile 1989, n. 20.; - Legge regionale 30 aprile 1996, n. 23 - Modifica alla L.R. 3 aprile 1989, n. 20; - Decreto Legislativo 29 Ottobre 1999, n.490 - Testo unico delle disposizioni legislative in materia di beni culturali e ambientali, a norma dell'art. 1 della legge 8 ottobre 1997, n. 352; - Decreto Legislativo 22 gennaio 2004, n. 42 - Codice dei beni culturali e del paesaggio, ai sensi dell’articolo 10 della legge 6 luglio 2002, n. 137 (Codice Urbani); - Decreto Legislativo 3 aprile 2006, n. 152 – Norme in materia ambientale (Codice dell’Ambiente o Testo unico dell’Ambiente). Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 6 Relazione tecnica L'opera è inoltre interessata dalle seguenti leggi in materia di acque pubbliche, aria e produzione di energia elettrica: - Regio Decreto 25 luglio 1904, n. 523 - Testo unico delle disposizioni di legge intorno alle opere idrauliche delle diverse categorie; - Regio Decreto 11 dicembre 1933, n. 1775 - Testo unico delle disposizioni di legge sulle acque e sugli impianti elettrici. Art.7: rilascio della concessione di derivazione; - Legge 5 marzo 1990, n. 46 - Norme per la sicurezza degli impianti; - Decreto del Presidente della Repubblica 6 dicembre 1991, n. 447 - Regolamento di attuazione della L. 46/90; - Legge 9 gennaio 1991, n. 9 - Norme per l'attuazione del nuovo Piano energetico nazionale: aspetti istituzionali, centrali idroelettriche ed elettrodotti, idrocarburi e geotermia, autoproduzione e disposizioni fiscali. Art. 22: Regime giuridico degli impianti di produzione di energia elettrica a mezzo di fonti rinnovabili e assimilate; Art. 23: Circolazione dell'energia elettrica prodotta da impianti di produzione di energia elettrica a mezzo di fonti rinnovabili e assimilate; - Legge 9 gennaio 1991, n. 10 - Norme per l'attuazione del Piano energetico nazionale in materia di uso razionale dell'energia, di risparmio energetico e di sviluppo delle fonti rinnovabili di energia; - Decreto Ministeriale 25 settembre 1992 - Approvazione della convenzione-tipo prevista dall'art. 22 L.9/91; - Decreto Legislativo 12 luglio 1993, n. 275 - Riordino in materia di concessione di acque pubbliche. Art.3: parere dell'Autorità di Bacino del Fiume Po; - Direttiva 96/92/CE del Parlamento Europeo e del Consiglio del 19 dicembre 1996 concernente - Norme comuni per il mercato interno di energia elettrica; - Delibera CIPE 137 del 19 novembre 1998 – Linee guida per le politiche e misure nazionali di produzione delle emissioni di gas serra; - Delibera n. 13/99 dell’Autorità per l’energia elettrica e il gas, pubblicazione G.U. serie generale n. 49 del 1 marzo 1999, concernente la disciplina delle condizioni tecnicoeconomiche del servizio di vettoriamento dell'energia elettrica e di alcuni servizi di rete; - Decreto Legislativo 16 marzo 1999, n. 79 - Attuazione della direttiva 96/92/CE, recante norme comuni per il mercato interno dell' energia elettrica. Art. 11: Fonti rinnovabili; - Decreto Legislativo 11 maggio 1999, n.152 - Disposizioni sulla tutela delle acque dall'inquinamento e recepimento della direttiva 91/271/CEE concernente il trattamento delle acque reflue urbane e della direttiva 91/676/CEE relativa alla protezione delle acque dall'inquinamento provocato dai nitrati provenienti da fonti agricole", a seguito delle disposizioni correttive ed integrative di cui al decreto legislativo 18 agosto 2000, n. 258; - Decreto Legislativo 4 agosto 1999, n. 351 – Attuazione della Direttiva 96/62/CE in materia di valutazione e di gestione della qualità dell’aria ambiente; - Legge Regionale 20 ottobre 2000, n. 52 - Disposizioni per la tutela dell'ambiente in materia di inquinamento acustico; - Legge Regionale 29 dicembre 2000, n. 61 - Disposizioni per la prima attuazione del D. Lgs. 11 maggio 1999, n. 152, in materia di tutela delle acque; Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 7 Relazione tecnica - Direttiva 2001/77/CE del Parlamento Europeo e del Consiglio del 27 settembre 2001 promozione dell’energia elettrica prodotta da fonti energetiche rinnovabili nel mercato interno di energia elettrica; - Decreto Legge 7 febbraio 2002, n. 7 - Misure urgenti per garantire la sicurezza del sistema elettrico nazionale; - Legge 9 aprile 2002, n. 55 - Conversione in legge, con modificazioni, del decreto legge 7 febbraio 2002, n. 7, recante misure urgenti per garantire la sicurezza del sistema elettrico nazionale; - Decreto Ministeriale 2 aprile 2002, n. 60 - Recepimento della direttiva 1999/30/CE del Consiglio del 22 aprile 1999 concernente i valori limite di qualità dell'aria ambiente per il biossido di zolfo, il biossido di azoto, gli ossidi di azoto, le particelle e il piombo e della direttiva 2000/69/CE relativa ai valori limite di qualità aria ambiente per il benzene ed il monossido di carbonio. - Regolamento regionale 29 luglio 2003, n. 10/R recante: “Disciplina dei procedimenti di concessione di derivazione di acqua pubblica (Legge regionale 29 dicembre 2000, n. 61); - Decreto Legislativo 29 dicembre 2003, n. 387 "Attuazione della direttiva 2001/77/CE relativa alla promozione dell'energia elettrica prodotta da fonti energetiche rinnovabili nel mercato interno dell'elettricità" ovvero denominato anche “Permesso Unico a Costruire ed a Esercire”. - Accordo di Programma Quadro per la tutela delle acque e la gestione integrata delle risorse idriche stipulato in data 18.12.2002 tra i Ministeri dell’Economica e delle Finanze, il Ministero dell’Ambiente e della tutela del territorio, il Ministero delle Infrastrutture e dei Trasporti, il Ministero delle Politiche agricole e Forestali e la Regione Piemonte, finalizzato, in particolare, al progressivo recupero quali-quantitato delle risorse idriche ed alla loro valorizzazione e tutela; dall’Accordo di Programma sono scaturiti ad oggi quattro Atti Integrativi, di cui l’ultimo è stato approvato con D.G.R. n. 11-5793 del 27.04.2007. Infine, si indica che è in attesa di perfezionamento di efficacia il Regolamento per l’utilizzo della risorsa idroelettrica, proposto dalla Provincia di Cuneo - Area funzionale del territorio settore risorse idriche ed energetiche ufficio concessioni di derivazione e pubblicato sul sito http://www.provincia.cuneo.it/risorse_idriche/pdf/regolamento_risorsaidroelettrica/1.pdf. L’elenco sopra esposto delinea in tutta la sua complessità il quadro normativo che attiene alle concessioni idroelettriche, che è decisamente articolato, per la molteplicità sia dei campi coinvolti come le risorse idriche, l’energia ed il complesso della tutela ambientale - sia delle competenze delle Amministrazioni coinvolte sul territorio. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 8 Relazione tecnica 2.3. Vincoli territoriali e ambientali Con riferimento alla normativa vigente è soggetta a vincolo ambientale e paesaggistico ai sensi del Decreto Legislativo 22 gennaio 2004 n°42 “ Decreto legislativo recante il Codice dei Beni Culturali e del Paesaggio, ai sensi dell’articolo 10 della legge 6 luglio 2002, n.137” in quanto ricadente all’interno della fascia di 150 metri dalle sponde del torrente Corsaglia. Il PRGC di Lesegno risulta essere aggiornato al PAI (di cui si allega un estratto planimetrico) e pertanto si rimanda al relativo capitolo riportato nei capitoli successivi. Non si segnalano invece in zona aree protette per la loro valenza ambientale quali SIC, SIR, ZPS. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 9 Relazione tecnica Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 10 Relazione tecnica La principale area di intervento, ovvero la sponda destra orografica (Comune di Lesegno) non ricade in zona sottoposta a vincolo idrogeologico (R.D. n. 3267/23; L.R. n. 45/89). Secondariamente il progetto interessa la sponda sinistra, Comune di San Michele, ove sono previsti interventi di adeguamento sulla traversa esistente; tale tratto insiste su area vincolata anche se va ricordato corrisponde all’alveo del Torrente Corsaglia. La zona ha vocazione prettamente agricola e si segnala la presenza di un’area servizi industriale, Acciaierie RIVA molto estesa posta sull’altopiano in destra orografica a circa 600 metri dall’area di intervento. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 11 Relazione tecnica 3. INQUADRAMENTO PROGRAMMATICO Nel presente paragrafo verranno analizzati i principali documenti di programmazione, di carattere sia generale sia settoriale, vigenti a livello regionale, provinciale e comunale, che possono essere di rilievo ai fini della realizzazione del progetto. L’individuazione e l’esame delle norme e dei vincoli in essi contenuti consente di verificare la rispondenza del progetto ai medesimi, intervenendo con opportune modifiche laddove risultino delle incompatibilità; l’analisi delle linee di sviluppo previste, invece, consente di valutare la compatibilità con riferimento sia alla situazione attuale, sia a quella prevista a seguito della realizzazione delle opere in oggetto. Pertanto il Quadro Programmatico è strumento complementare del “Quadro Normativo”, in quanto, non soltanto indirizza la progettazione verso il rispetto delle norme e dei vincoli esistenti, ma garantisce il corretto inserimento dell’opera nel contesto territoriale. Nel caso in esame sono stati considerati i seguenti strumenti di programmazione generale: 3.1.1. ⋅ Il Piano Territoriale Regionale (P.T.R.); ⋅ Il Piano Paesaggistico Regionale (P.P.R.); ⋅ Il Piano Territoriale di Coordinamento della Provincia (P.T.C.P.); ⋅ Piani sull’ambiente idrico (P.A.I., P.T.A., P.D.R.I.); ⋅ Il Piano per la qualità dell’aria (P.Q.A.) ⋅ Il Piano Regolatore Generale Comunale di Lesegno e di san Michele Mondovì (P.R.G.C.); ⋅ Il Piano di Zonizzazione Acustica (P.Z.A.); ⋅ Il Programma Territoriale Integrato (P.T.I.); ⋅ La Pianificazione energetica. Il Piano Territoriale Regionale – PTR Benché si tratti di un documento di area vasta, dall’analisi degli allegati cartografici del P.T.R. in scala 1:250.000, sono emerse alcune interessanti indicazioni riguardanti il territorio in cui si inserisce l’opera in oggetto. In relazione ai Caratteri territoriali e paesaggistici individuati nel Piano, il sito in esame ricade all’interno delle aree indicate come Sistema dei suoli a media produttività; «tali aree comprendono suoli di media fertilità, con un un limitato valore agronomico. In relazione a esse, si pongono le problematiche di riqualificazione morfologica e funzionale dell'ambiente urbano, di "ridisegno" e "ricucitura" dei tessuti insediativi, di integrazione tra funzioni complesse, residenziali, terziarie e produttive: è in queste aree che potranno trovare collocazione eventuali flussi di riurbanizzazione nelle aree individuate dalle dorsali di riequilibrio, nelle rimanenti aree destinazioni diverse da quella agricola solo con adeguata motivazione. Conseguentemente, la programmazione di settore si connota per una minore centralità delle esigenze agricole, alle quali si affiancano, assumendo un rilievo che può anche essere prevalente, altri obiettivi, legati ai processi di rilocalizzazione delle residenze e delle attività produttive». La figura successiva riporta uno stralcio della Tavola 1 – Caratteri territoriali e paesaggistici del P.T.R.., dalla quale si desume che non emergono indicazioni interessanti circa l’area in cui si inserisce l’opera in oggetto. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 12 Relazione tecnica La Figura riporta uno stralcio della Tavola 1 – Caratteri territoriali e paesaggistici del P.T.R.. Per quanto riguarda il Torrente Corsaglia, protagonista del progetto in esame ed affluente del Fiume Tanaro, esso appartiene all’elenco dei CORSI D’ACQUA PRINCIPALI (art. 20 delle Norme), cioè compresi negli elenchi delle acque pubbliche classificate, quindi è sottoposto a controllo e gestione diretta della Regione al fine della tutela paesistico-ambientale del sistema fluviale del Piemonte, ovvero al rilascio delle autorizzazioni di cui all'art. 7 della legge 1497/39, in conformità al disposto dell'art. 10 della L.R. 20/1989. Il P.T.R. prevede che all'interno del sistema di controllo a gestione diretta «la Regione provvederà a definire specifici piani con valenza paesistica relativi ai corsi d'acqua. In relazione alla L. 183/1989, riguardante gli interventi sulla rete idrografica e sui versanti, a tutti più nota come Piano Stralcio dell’Assetto Idrogeologico del Territorio (PAI), relativamente al Torrente Corsaglia non si osservano particolari indicazioni. Per ulteriori ed opportuni approfondimenti in merito, si rimanda a quanto riportato nei capitoli della pianificazione sull’ambiente idrico e dalla Relazione Geologica. La disciplina di settore del bene primario costituito dalle risorse idriche è contenuta nel Piano Direttore delle Risorse Idriche (P.D.R.I., cui si rimanda, cfr. Capitolo 1.3.3.2), da considerarsi parte integrante del P.T.R. e chiarente le norme volte a perseguire gli obiettivi del miglioramento della qualità dell'acqua, della sistemazione idrogeologica, della valorizzazione ambientale, nel quadro delle competenze delineato dal D.Lgs. 192/1999 prima e dal Testo Unico Ambiente, D.Lgs. 152/2006, Parte Terza, “Norme in materia di difesa del suolo e lotta alla desertificazione, di tutela delle acque dall’inquinamento e di gestione delle risorse idriche”. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 13 Relazione tecnica Con riferimento agli Indirizzi di governo del territorio, la Tavola 2 del Piano mostra come il territorio di San Michele Mondovì e Lesegno sia attraversato da una strada principale, la Strada Statale n°28, dalla ferrovia Torino – Savona, oltre che dal torrente Corsaglia. Da un esame della tavola non si rileva alcuna particolare evidenza nell’area oggetto dell’intervento in questione. . La Figura riporta un stralcio della Tavola 2 – Indirizzi di governo del territorio del P.T.R.. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 14 Relazione tecnica 3.1.2. Il Piano Paesaggistico Regionale (P.P.R.) La Regione Piemonte ha avviato nel 2005 una nuova fase di pianificazione dell’intero territorio regionale, che comporta in particolare la formazione del Piano Paesaggistico Regionale (Ppr) ai sensi del Codice dei Beni Culturali e del Paesaggio (D.Lgs 42/2004) e della Convenzione Europea del Paesaggio (Consiglio d’Europa, 2000). La Giunta Regionale, con DGR n. 53-11975 del 4 agosto 2009 ha adottato il Piano Paesaggistico. Nel quadro del processo di pianificazione territoriale avviato dalla Regione, il Ppr rappresenta lo strumento principale per fondare sulla qualità del paesaggio e dell’ambiente lo sviluppo sostenibile dell’intero territorio regionale. L’obiettivo centrale è perciò la tutela e la valorizzazione del patrimonio paesaggistico, naturale e culturale, in vista non solo del miglioramento del quadro di vita delle popolazioni e della loro identità culturale, ma anche del rafforzamento dell’attrattività della regione e della sua competitività nelle reti di relazioni che si allargano a scala globale. Il Piano è costituito dai seguenti elaborati: Relazione; Norme di Attuazione; Tavole di Piano P1 Quadro strutturale; P2 Beni paesaggistici; P3 Ambiti e unità di paesaggio; P4 Componenti paesaggistiche; P5 Rete ecologica, storico culturale e fruitiva; - Schede degli ambiti di paesaggio Elenchi delle componenti e delle unità di paesaggio; Rapporto ambientale e sintesi non tecnica. Le informazioni di maggior interesse, con riferimento all’ambito di intervento, sono costituite da quelle desumibili dalla tavola P5 – Rete ecologica, storico culturale e fruitiva. Con riferimento al sistema integrato delle reti e riportato in figura di cui sopra, il Ppr persegue i seguenti obiettivi: assicurare le condizioni di base per la sostenibilità ambientale dei processi di crescita e di trasformazione e conservazione attiva della biodiversità; assicurare un’adeguata tutela e accessibilità delle risorse naturali e paesaggistiche; ridurre e contenere gli impatti negativi sul paesaggio e sull’ambiente; valorizzare il patrimonio culturale regionale anche in funzione della sua accessibilità e fruibilità; migliorare le prestazioni delle infrastrutture dedicate alla fruizione paesaggistica ed ambientale. Con riferimento all’importanza in termini naturalistici, nella tavola della Rete Ecologica del piano, l’area di intervento è segnalata come “aree rurali in cui ricreare connettività diffusa”. Non si segnalano invece nodi principali o secondari (Core areas) e neanche aree tampone (Buffer Zone). Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 15 Relazione tecnica 3.1.3. Piano Territoriale di Coordinamento della Provincia di Cuneo Tra i vari progetti previsti dal PTCP, si pone l’attenzione sui progetti in cui bene s’inserisce il progetto in esame o che interagiscono con esso: «C.1. politiche per il ripristino di condizioni di sicurezza dei corsi d'acqua e la prevenzione dei rischi di esondazione con prioritario riferimento alle indicazioni del P.A.I: la ricostruzione di una rete di misurazione-monitoraggio degli eventi meteorici e delle portate dei corsi d'acqua e la loro integrazione in un sistema informativo e di simulazione capace di definire i livelli di piena dei corsi d'acqua a fronte degli eventi meteorici prevedibili a cadenze periodiche progressive (sino alla piena centenaria e millenaria); l'esercizio di una manutenzione programmata degli alvei volta a rendere compatibili le esigenze di conservazione ambientale con quelle di sicurezza idraulica; l'individuazione delle aree a rischio di esondazione sulla base delle indicazioni e delle disposizioni del P.A.I. della Autorità di Bacino del Po e l'adozione dei conseguenti provvedimenti e la regolazione degli usi delle stesse che ne escludano impieghi in contrasto con le esigenze di sicurezza idraulica; l'individuazione degli insediamenti a rischio di esondazione e la individuazione delle misure idonee a mitigare il rischio medesimo (valutando anche gli effetti indotti a valle e a monte sul corso d'acqua) e prendendo ove del caso in considerazione le ipotesi di rilocalizzazione degli stessi; […]» Il Comune di Lesegno e San Michele M.vì hanno recepito quanto richiesto dal P.A.I.; si rimanda al paragrafo relativo al - Piano Regolatore Generale (P.R.G.C.) dei comuni di Lesegno e San Michele M.vì - per quanto riguarda le previsioni urbanistiche ed al Quadro Progettuale per quanto riguarda le opere idrauliche in progetto. «E.2. politiche di risanamento, riabilitazione ambientale e riqualificazione paesistica, volte alla mitigazione degli effetti di attività ad elevato impatto ambientale (discariche, cave) anche attraverso il recupero delle superfici relitte e l'incentivazione alla riorganizzazione del tessuto insediativo in modo da non compromettere le azioni di valorizzazione ambientale.» «E.3. politiche di risanamento e riabilitazione ambientale dei corsi d'acqua, con particolare riferimento: alla valutazione delle portate nelle varie sezioni in relazione agli utilizzi in conformità alle disposizioni normative vigenti (portate minime vitali) […]». In relazione alla realizzazione dell’opera in oggetto, il progetto E3 rappresenta evidentemente una delle necessarie verifiche da attuare anche ai fini della funzionalità dell’opera; si rimanda, quindi, per le valutazioni di dettaglio ai successivi quadri progettuale e ambientale. «E.5. politiche di qualificazione del patrimonio bio-vegetazionale e di allestimento della rete ecologica provinciale attraverso azioni volte a realizzare la continuità tra i principali siti di interesse naturalistico (Parchi, SIC, Biotopi), migliorare il contenuto paesistico, e la ricchezza faunistica di tutti i quadri ambientali ed in particolare di quelli di collina e di pianura, a qualificare in termini ecologici l'ambiente forestale anche attraverso una accurata selezione di essenze negli interventi di forestazione, e a consentire livelli di fruizione compatibili con la fragilità specifica dei luoghi.» «E.6. politiche di regolazione dell'attività estrattiva con particolare riferimento alle esigenze di tutelare le aree di maggiore sensibilità ambientale della pianura, di garantire condizioni di sicurezza e di fruibilità degli ambienti fluviali e di mitigare gli impatti paesistici delle cave di monte nelle aree collinari e montane a partire da: maggiore attenzione alle modalità di ripristino dei luoghi nel rispetto della situazione preesistente e della fruizione futura predisposizione di “piani regolatori” estesi all’intero territorio dei “poli estrattivi” previsti dalla legislazione vigente in particolare per l’estrazione di materiali di pregio in zone montane, con l’obiettivo di coordinare l’attività dei soggetti operanti, di adottare vie di trasporto comuni, di posizionare siti di discarica comuni.» In relazione al progetto E6, si osserva che le moderate quantità di materiale estratto per la realizzazione dell’impianto ed il suo previsto utilizzo, diverso dal commercio, fanno sì che l’intervento non si configuri come attività estrattiva ai sensi della L.R. 69/1979. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 16 Relazione tecnica A seguito della proroga rispetto alla scadenza di gennaio 2007, si resta in attesa del Decreto ministeriale, da adottarsi da parte del Ministero dell'ambiente e della tutela del territorio, relativo alla disciplina per la semplificazione amministrativa delle procedure relative ai materiali (ivi incluse terre e rocce da scavo) provenienti da cantieri di piccole dimensioni (ovvero quelli, la cui produzione non superi i seimila metri cubi di materiale). «E.10. politiche energetiche, a partire dalle previsioni del Piano Energetico Generale della Provincia di Cuneo, con gli obiettivi di una riduzione delle emissioni in atmosfera, di rendere il sistema energetico provinciale meno vulnerabile, di aumentare l’indipendenza energetica della provincia, utilizzare la razionalizzazione e la sostituzione energetica come strumenti per creare nuovo sviluppo economico e occupazione a livello locale, attraverso: […] l'incentivazione di progetti di risparmio energetico (isolamento termico, manutenzione degli impianti, biogas, cogenerazione, recupero energia inceneritori, ecc.) e di produzione di energia di fonti rinnovabili (geotermia, eolico, solare, ecc.), la diffusione di piccole centrali idroelettriche nelle aree montane, la produzione di energia attraverso la termodistruzione dei R.S.U.; […] Promozione di iniziative nei settori dei trasporti privati, dell’industria e del terziario con l’obiettivo della riduzione dei consumi energetici.» In relazione all’interazione tra i progetti E5, E6, E10 ed il progetto in oggetto, trattandosi di tematiche strettamente connesse alle valutazioni d’obbligo, si rimanda per le considerazioni di dettaglio al quadro progettuale contenuto nella presente relazione tecnica e alla relazione “Compatibilità ambientale al prelievo”. 3.1.4. Piani sull’ambiente idrico: P.A.I., P.D.R.I. e P.T.A. P.A.I. Il Piano stralcio per l’assetto Idrogeologico, P.A.I., è stato approvato dal Comitato Istituzionale dell'Autorità di bacino del fiume Po con Deliberazione n.1/99 in data 11 maggio 1999. Il Piano prevede l'inserimento dei Comuni del bacino del Po in classi di rischio e l'individuazione di aree a diversa pericolosità idraulica e idrogeologica in relazione ad alcune tipologie di fenomeni prevalenti: Frane, Esondazione e dissesti morfologici di carattere torrentizio lungo le aste dei corsi d'acqua, Trasporto di massa su conoidi, Valanghe. Per quanto riguarda la classificazione delle aree interessate da fenomeni di dissesto, la normativa allegata al PAI prevede più categorie per ogni tipologia di rischio: ⋅ Frane: Fa, aree interessate da frane attive (pericolosità molto elevata) Fq, aree interessate da frane quiescienti (pericolosità elevata) Fs, aree interessate da frane stabilizzate (pericolosità media o moderata) ⋅ Esondazioni: Ee, aree potenzialmente coinvolte da feniomeni con pericolosità molto elevata o elevata Eb, aree potenzialmente coinvolte da fenomeni con pericolosità moderata o media ⋅ Conoidi: Ca, aree di conoidi attivi o potenzialmente attivi non protette da opere di difesa e di sistemazione a monte (pericolosità molto elevata) Cp, aree di conoidi attivi o potenzialmente attivi parzialmente protette da opere di difesa (pericolosità elevata) Cn, aree di conoidi non recentemente riattivatisi o completamente protette da opere di difesa (pericolosità media o moderata). Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 17 Relazione tecnica ⋅ Valanghe: Ve, aree di pericolosità elevata o molto elevata Vm, aree di pericolosità media o moderata. Il progetto di derivazione in oggetto ad esclusione ovviamente della traversa fluviale, della presa e delle opere interrate dell’impianto idroelettrico non interessa aree vincolate PAI o meglio l’unico fabbricato emergente (locale Enel e quadri) è esterno all’area di vincolo del PAI. P.D.R.I. Il Piano Direttore Regionale delle Risorse Idriche P.D.R.I., elaborato sulla base della Proposta di Direttiva del consiglio della Comunità Europea, attualmente Dir. 2000/60/CE, è stato approvato con D.C.R. n. 103-36782 del 12/12/2000. Il documento definisce la politica regionale di governo delle risorse idriche al fine di raggiungere l'obiettivo di una più sostenibile gestione delle medesime e degli ambienti ad esse correlati, ovvero di un equilibrio tra i fabbisogni idrici dello sviluppo economico e sociale e la tutela quali-quantitativa della risorsa. Il raggiungimento di tale obiettivo generale viene attuato attraverso l’analisi della situazione attuale delle risorse idriche piemontesi e la successiva definizione degli obiettivi strumentali e dei criteri che sono alla base delle azioni strumentali di risanamento e delle azioni di governo di seguito individuate ai fini della attuazione della politica regionale di gestione delle medesime. Tralasciando la descrizione dello stato attuale delle risorsa idrica che viene trattata in maniera specifica nella Relazione di Impatto Ambientale in un apposito capitolo, il documento in esame riporta quali azioni strumentali e di governo validi ai vari livelli territoriali, i seguenti interventi, specifici per problematica quali : • Risanamento e riqualificazione dei corpi idrici • Corretto e razionale uso delle acque • - Riequilibrio del bilancio idrico; - Maggiore e/o migliore tutela della risorsa idrica e degli ambienti acquatici. Conoscenza - • Controllo - • Adozione di un approccio combinato che prevede verifiche contestuali dello stato del corpo idrico e delle matrici ambientali, del negoziato controllore-controllato, degli effetti che si producono sul bene tutelato in seguito all’attuazione di scelte di fondo normative, pianificatorie e programmatorie. Pianificazione - • Sviluppo di un sistema di reti di monitoraggio delle acque superficiali e sotterranee, ai vari livelli regionale, provinciale e comunale. Continui confronto ed integrazione dei Piani idrici di livello regionale, provinciale, comunale con i diversi strumenti di pianificazione territoriale. Informazione e sensibilizzazione - Sviluppo di una nuova cultura dell’uso e del risparmio della risorsa idrica mediante: pubblicazione, diffusione e messa a disposizione di dati ed informazioni detenute dalla pubblica amministrazione e/o reperite con ricerche, indagini e studi effettuati nell’ambito, formazione mirata e qualificata degli operatori di settore, compilazione e diffusione di guide normative e tecniche di comparto, promozione Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 18 Relazione tecnica di specifici processi educativi e formativi nell’ambito degli istituti scolastici di ogni grado, compreso quello universitario. La Provincia di Cuneo ha recepito i contenuti del Piano Direttore delle Risorse Idriche ed attuato parte delle azioni in esso contenute mediante: - L’elaborazione del Piano delle acque, relativo al 1992 e costituente stralcio del Piano Territoriale di Coordinamento in materia di acque; - La partecipazione al Progetto Tanaro (1997-1999), mediante il quale è stato possibile conoscere, grazie a successivi monitoraggi, la distribuzione dei produttori di inquinamento e la dislocazione dei preventori e riduttori dello stesso sui territori del bacino idrografico di pianura del fiume (Province di Alessandria, Asti e Cuneo) nonché creare banche dati e cartografie tematiche informatizzate aggiornabili ed incrementabili. P.T.A. In data 6.04.2004, con deliberazione n. 21-12180, la Giunta Regionale ha approvato il Progetto di Piano di Tutela delle Acque (P.T.A.). Il P.T.A. persegue l’obiettivo della «protezione e valorizzazione del sistema idrico piemontese nell’ambito del bacino di rilievo nazionale del fiume Po e nell’ottica dello sviluppo sostenibile della comunità» (Norme, art. 1 c.2.). Il P.T.A., sulla base dei risultati dell’attività conoscitiva svolta, individua (Norme, art. 2.1.): - i corpi idrici soggetti a obiettivi di qualità ambientale; - i corpi idrici a specifica destinazione ed i relativi obiettivi di qualità funzionale; - le aree sottoposte a specifica tutela. Inoltre, definisce (Norme, art. 2.2.): - le misure, tra loro integrate, di tutela qualitativa e quantitativa e di gestione ambientale sostenibile delle acque superficiali e sotterranee; - la cadenza temporale degli interventi e delle relative priorità; - il programma di verifica dell'efficacia degli interventi previsti e di costante aggiornamento delle misure di tutela. Per quanto riguarda i prelievi da acque superficiali nell’elaborazione del PTA, è stata condotta un’analisi dei prelievi da acque superficiali sul territorio regionale basata sui dati contenuti del “Catasto derivazioni idriche” della Regione Piemonte (2003); l’analisi è stata condotta considerando solo le utenze attive. Questo “ha permesso di operare una prima caratterizzazione delle pressioni legate ai prelievi idrici, che conduce ad una prima individuazione sul territorio delle possibili cause delle criticità quantitative sui corpi idrici superficiali; gli indicatori di pressione sul territorio utilizzati a tal fine, sono stati basati sui volumi di prelievo di risorsa assentiti dalle attuali concessioni per i diversi usi.” In particolare, per l’ALTO TANARO (bacino a cui appartiene il torrente Corsaglia) si evidenzia quanto segue: «Il livello di compromissione quantitativa della risorsa idrica superficiale sull'Alto Tanaro si può stimare come medio-alto, in relazione agli altri bacini regionali, in quanto, se sull'asta principale del Tanaro non sussistono particolari pressioni che causino depauperamenti significativi di risorsa, a meno delle condizioni di criticità locale sui tratti sottesi da impianti idroelettrici, sulle aste dei tributari il livello di compromissione è decisamente maggiore, specialmente sul Pesio.» Relativamente ai prelievi idroelettrici, il PTA osserva che gli impianti ad acqua fluente provocano “…sottensione di tratti più o meno lunghi di asta fluviale, con conseguenti depauperamenti di risorsa che alterano le normali condizioni di vitalità dell’ecosistema fluviale, condizionano la naturale capacità autodepurativa del corso d’acqua stesso e riducono le disponibilità idriche per gli usi di valle; anche in questo caso si tratta di criticità locale che non risulta alterare il bilancio idrico a scala di bacino”. A questo proposito il Regolamento per l’utilizzo della Risorsa idroelettrica rileva che “… è importante notare come le modifiche al bilancio idrico definite dal PTA siano molto limitate: gli impianti Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 19 Relazione tecnica idroelettrici, in generale, rappresentano quindi esclusivamente delle criticità locali, e quindi, come tali, non sono obbiettivo primario del PTA.” il P.T.A. tiene conto del torrente Corsaglia in quanto affluente del Fiume Tanaro. In particolare, per quanto riguarda il Torrente Corsaglia il PTA non riporta particolari criticità o osservazioni in nessuna delle carte e dei documenti disponibili, né il Torrente Corsaglia risulta in qualche modo monitorato sotto il profilo quali-quantitativo. In particolare, il Torrente Corsaglia non risulta “fasciato” ai sensi del P.A.I., non è sottoposto a protezione e miglioramento per idoneità alla vita dei pesci ed agli sport di acqua viva, non risulta vulnerabile da nitrati di origine agricola, né da prodotti fitosanitari, non appartiene per tutto il suo percorso ad aree protette (nazionali, regionali, provinciali) né a S.I.C. (Direttiva “Habitat”) né a Z.P.S. (Direttiva “Uccelli”). In quanto affluente del Fiume Tanaro (CORSO D’ACQUA NATURALE SIGNIFICATIVO), il Torrente Corsaglia è indicato dal PTA nell’Allegato 4 tra i CORSI D’ACQUA NATURALI POTENZIALMENTE INFLUENTI SUI CORSI D’ACQUA SIGNIFICATIVI O DI RILEVANTE INTERESSE AMBIENTALE; da questo deriva il fatto che il Torrente Corsaglia è indicato tra i CORPI IDRICI SOGGETTI A OBIETTIVI DI QUALITÀ AMBIENTALE ed è monitorato mediante prelievo in due punti. Il Torrente Corsaglia appartiene all’Unità Sistemica di Riferimento AI19 – ALTO TANARO; (Norme di Piano, art. 16.) «Costituiscono unità sistemiche di riferimento del Piano di tutela delle acque le aree di cui all’allegato 3 e alle tavole di piano n. 1 e n. 2 distinte in: a) per quanto concerne le acque superficiali: 1) sottobacini e aree idrografiche; 2) laghi; b) per quanto concerne le acque sotterranee: 1)aree idrogeologicamente separate dell’acquifero superficiale; 2) macroaree idrogeologiche di riferimento dell’acquifero superficiale; 3) macroaree idrogeologiche di riferimento dell’acquifero profondo.» Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 20 Relazione tecnica 3.1.5. Piani Regolatori Generali Comuni interessati dall’intervento (P.R.G.C.) Lesegno È attualmente stata apportata una variante al P.R.G.C. del Comune di Lesegno: la Variante Strutturale n. 16 al Piano Regolatore Generale, redatta ai sensi della L.R. 01/2007 e L.R. 56/77. La variante al piano regolatore prevede l’adeguamento dello stesso alle norme del PAI: “Procedura di condivisione del Quadro di dissesto in conformità ai criteri del PAI”. Di seguito viene riportato l’estratto cartografico del Piano Regolatore. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 21 Relazione tecnica Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 22 Relazione tecnica L’impianto in progetto trova localizzazione lungo il Torrente Corsaglia in sponda destra orografica sulla traversa ove origina in sinistra la derivazione irrigua di San Gervasio. L’intervento in progetto ricade in “area agricola normale”. Le opere relative all’impianto ricadono in area Ee – Classe IIIa2 di Pericolosità geomorfologica. L’edificio della cabina ENEL contenente anche i quadri di gestione ed i trasformatori (unico fabbricato ergente) è invece previsto esterno dalla Fascia di pericolosità Ee e ricade in area Classe III. La compatibilità tra quanto prescritto dalle NTA del Piano ed il progetto in oggetto sarà valutata nell’ambito dell’istruttoria, prevista dal procedimento amministrativo ex art. 10 della L.R. 40/1998, tra i cui obbiettivi fondamentali c’è anche quello di “rendere coerente l’attività di pianificazione e programmazione con gli obiettivi di tutela ambientale” (L.R. 40/1998, art. 1 - Finalità), valutando i costi ed i benefici connessi con l’opera. Secondo quanto disposto dalla documentazione di piano, l’intervento proposto è collocato per la parte emergente (fabbricato ENEL/quadri) al di fuori di aree vincolate dal PAI (fuori dalle aree Ee e dalle fasce fluviali), mentre la traversa, la presa e i locali tecnici interrati sono in “porzioni di territorio inedificate, …..inidonee a nuovi insediamenti, dove le opere infrastrutturali di grande interesse pubblico non altrimenti localizzabili debbono essere autorizzate in deroga …. “ Il P.R.G.C. evidenzia, quindi, totale compatibilità con la costruzione del fabbricato, mentre per le altre infrastrutture che sono praticamente a raso piano campagna ( innalzamento traversa con accorgimento mobile, presa e scarico) sono ammissibili se considerate di interesse pubblico e non altrimenti localizzabili. Sul fatto di “non altrimenti localizzabile” si dichiara sin d’ora che viene predisposta una documentazione specifica denominata “Compatibilità con lo stato di dissesto esistente” come richiesto espressamente dall’Autorità di Bacino per il Fiume Po, da inoltrare alla Regione Piemonte Settore OO.PP. di Cuneo. Va poi ricordato che l’impianto di derivazione delle acque a fini energetici è di sicuro interesse pubblico. A quanto visto va aggiunto che la scelta del sito oltre a dover soddisfare i requisiti “normativi” deve anche rispondere a specifiche esigenze “tecniche”. Perché un intervento sia “fattibile”, infatti, è Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 23 Relazione tecnica necessario che la sua realizzazione comporti il raggiungimento del miglior rapporto costi÷benefici, dove i costi sono rappresentati oltre dalle spese che il proponente deve affrontare per la realizzazione del progetto, anche dalle ricadute negative ambientali del medesimo, ed i benefici sono costituiti dai vantaggi che ne derivano per la comunità e per il privato nonché dagli effetti positivi ambientali e territoriali. La scelta del sito concorre, dunque, con tutta la progettazione dell’opera, alla definizione di detto bilancio, pertanto è necessario valutare più localizzazioni alternative optando per quella che comporta meno costi e più benefici. Nel caso in esame detta procedura ha portato alla individuazione della soluzione presentata nel presente progetto. Inoltre, l’area su cui insiste l’impianto in progetto è tutelata ai sensi del D.Lgs. 22 gennaio 2004, n. 42 – Codice dei beni culturali e del paesaggio, ai sensi dell’art. 10 della L. 6 luglio 2002, n. 137 (c.d. Codice Urbani) pertanto è necessario avviare, contestualmente al procedimento di Verifica ai sensi della Legge Reg. n°40 del 1998 art.10, apposita pr ocedura di autorizzazione ai sensi dell’art. 146 del Codice, presentando idonea Relazione Paesaggistica, di cui al D.P.C.M. 12.12.2005. Classificazione acustica del territorio comunale In relazione agli adempimenti previsti in materia di inquinamento acustico dalla L.R. 52 del 20 ottobre 2000, “Disposizioni per la tutela dell’ambiente in materia di inquinamento acustico” (in attuazione di quanto previsto dalla L. n. 447 del 26.10.1995), il Comune di Lesegno ha adottato la Classificazione Acustica del proprio territorio – adottata con Consiglio Comunale n. 25 del 23/09/2004. Lo studio di zonizzazione acustica è stato realizzato seguendo le linee guida emanate dalla Regione Piemonte con Delibera n. 85-3802 del 06.08.2001, che prevede la suddivisione dell’attività in 5 fasi, dalla fase 0 alla fase 4, cioè dall’acquisizione dei dati ambientali ed urbanistici all’inserimento delle fasce cuscinetto” e delle fasce di pertinenza delle infrastrutture dei trasporti. Al termine di questo lavoro è stata elaborata una cartografia con la proposta di classificazione. Secondo la classificazione proposta, per il caso in esame si osserva che la fascia fluviale afferente il Torrente Corsaglia ed il territorio della Valle di Corsaglia sono inseriti prevalentemente nella Classe acustica III, che è quella solitamente individuata per le aree urbane interessate dal traffico veicolare locale o di attraversamento, con media densità di popolazione, con presenza di attività commerciali, uffici, limitata presenza di attività artigianali e assenza di attività industriali; le aree rurali interessate da attività che impiegano macchine operatrici, ovvero per le “aree di tipo misto”, e pertanto deve rispettare i seguenti limiti: Limiti per la Classe III Classe acustica III Periodo diurno (6-22) Periodo notturno (22-6) Emissione 55 45 Immissione 60 50 Le opere dell’impianto sotto l’aspetto delle emissioni sonore rientrano per il comune di Lesegno in Classe acustica III Poiché l’area in cui è in progetto l’opera in esame è poco urbanizzata/edificata, si rileva che per il territorio del comune di Lesegno i ricettori sensibili nelle vicinanze dell’opera sono a circa 600 metri di distanza e sono le case di località “La Gatta”. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 24 Relazione tecnica San Michele M.vì E’ attualmente vigente nel Comune di San Michele Mondovì la Variante Parziale n. 10 al Piano Regolatore Generale, redatta ai sensi dell’art. 17, c. 7, della L.R. 56/1997 e della L.R. n. 41/1997 ed adottata con Delibera del Consiglio Comunale n. 13 del 30.05.2006. Inottemperanza a quanto disposto dagli artt. 22 e 25 delle NTA si è provveduto a consultare le citate Tavole allegate alla Relazione Geologico Tecnica ed è emerso quanto segue: • l’area in esame è caratterizzata da una fascia a ridosso del Corsaglia e dell’area alluvionabile (“area inedificabile a causa dell’elevato rischio di alluvionamento ed esondazione”) è classificata come Zona di rispetto dal corso d’acqua, Area non edificabile; Inoltre, l’intero territorio comunale è sottoposto a vincolo idrogeologico ai sensi del R.D. n. 3267/1923; questo comporta una pratica di “svincolo idrogeologico” da effettuarsi contestualmente all’istanza di Permesso di Costruire, che sarà valutata ed eventualmente autorizzata dal Comune di San Michele. La pratica citata sarà corredata dagli opportuni elaborati progettuali atti a dimostrare la coerenza con gli articoli delle NTA. La compatibilità tra quanto prescritto dalle NTA ed il progetto in oggetto dovrà essere valutata nell’ambito della Conferenza dei Servizi, prevista dal procedimento amministrativo ex art. 10 della L.R. 40/1998, tra i cui obbiettivi fondamentali c’è anche quello di “rendere coerente l’attività di pianificazione e programmazione con gli obiettivi di tutela ambientale” (L.R. 40/1998, art. 1 - Finalità), valutando i costi ed i benefici connessi con l’opera. Nella cartografia che segue è illustrato un estratto planimetrico della tavola del Piano Regolatore con relativa legenda dove appare evidente che la zona intorno all’area di intervento è classificata come agricola. E’ da fare rilevare che gli interventi progettuali insistono in comune di Lesegno, soltanto metà traversa è in comune di San Michele M.vì, ma la traversa insiste in alveo demaniale. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 25 Relazione tecnica Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 26 Relazione tecnica Classificazione acustica del territorio comunale In relazione agli adempimenti previsti in materia di inquinamento acustico dalla L.R. 52 del 20 ottobre 2000, “Disposizioni per la tutela dell’ambiente in materia di inquinamento acustico” (in attuazione di quanto previsto dalla L. n. 447 del 26.10.1995), il Comune di San Michele Mondovì ha adottato la Classificazione Acustica del proprio territorio nel Consiglio Comunale n. 47 del 30.09.2004. Secondo la classificazione proposta, per il caso in esame si osserva che l’intera fascia fluviale afferente il Torrente Corsaglia ed il territorio della Valle di Corsaglia sono inseriti nella Classe acustica III, che è quella solitamente individuata per le aree urbane interessate dal traffico veicolare locale o di attraversamento, con media densità di popolazione, con presenza di attività commerciali, uffici, limitata presenza di attività artigianali e assenza di attività industriali; le aree rurali interessate da attività che impiegano macchine operatrici, ovvero per le “aree di tipo misto”, e pertanto deve rispettare i seguenti limiti: Limiti per la Classe IIII Classe acustica III Periodo diurno (6-22) Periodo notturno (22-6) Emissione 55 45 Immissione 60 50 Gli estratti planimetrici e la legenda della zonizzazione acustica sono illustrati nelle tavole a seguire. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 27 Relazione tecnica Le opere dell’impianto sotto l’aspetto delle emissioni sonore anche per il comune di San Michele M.vì rientrano in Classe acustica III. Poiché l’area in cui è in progetto l’opera in esame è poco urbanizzata/edificata, si rileva che per il territorio del comune di San Michele M.vì i ricettori sensibili nelle vicinanze dell’opera sono rispettivamente a circa 180 e 250 metri di distanza e sono le case Rimbaldo e la borgata San Gervasio. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 28 Relazione tecnica 3.1.6. Programmazione in materia di “energia” La programmazione in materia di energia si presenta molto articolata a causa del sovrapporsi della legislazione nazionale con gli indirizzi e le politiche internazionali, sia europee sia mondiali. Si cercherà nel presente capitolo di rendere un quadro più completo possibile della programmazione esistente in materia, senza trascurare le numerose notizie che hanno coinvolto gli operatori del settore nel corso degli ultimi tre anni. Pianificazione energetica internazionale È evidente che per la tipologia progettuale occorre prendere in analisi fin dalla fonte primaria quanto previsto dai piani e programmi che mirano a sovraordinare la materia del risparmio energetico connesso alla riduzione dell’impatto dovuto alle attività energivore del mondo industrializzato. In quest’ottica è opportuno iniziare dal Protocollo di Kioto del 10 dicembre 1997, che ha fissato gli obiettivi di riduzione dei gas serra entro il 2012 per i Paesi industrializzati; contestualmente l’Unione Europea ha fissato i seguenti obiettivi: a) ridurre l’utilizzo dei combustibili fossili contestualmente alla riduzione dell’8% delle emissioni di gas serra; b) ridurre l’importazione di energia al fine di acquisire maggiori flessibilità, economicità e sicurezza negli approvvigionamenti energetici; c) creare e sviluppare la produzione di energia maggiormente rispondente alle esigenze della piccola e media impresa; La Direttiva 2001/77/CE del 27 settembre 2001 sulla promozione dell’energia prodotta da fonti energetiche rinnovabili nel mercato interno dell’elettricità mira a definire un quadro complessivo di sviluppo delle fonti rinnovabili all’interno dell’Unione Europea coerente con gli obiettivi fissati dal Protocollo di Kyoto in termini di riduzione delle emissioni climalteranti. Nel documento vengono fissati: i valori di riferimento per gli obiettivi indicativi nazionali relativamente al contributo dell’elettricità prodotta da fonti energetiche rinnovabili (rispetto alle previsioni di consumo lordo di elettricità entro il 2010); il calendario delle scadenze per gli Stati membri; le modalità di armonizzazione del settore con le regole del mercato interno dell’elettricità in termini di sostegno, trasparenza e semplificazione delle procedure amministrative; le garanzie di trasmissione e distribuzione dell’energia elettrica da fonti rinnovabili negli Stati membri. Dalle decisioni prese a livello europeo, per l’Italia si profila un duplice obiettivo: 1. la produzione di energia elettrica da fonti rinnovabili in quantità pari al 25% del totale dell’energia prodotta al 2010 (nel 1997 è stato registrato il 16%); 2. entro il 2008-2012, la riduzione delle emissioni del 6,5% rispetto ai livelli registrati nel 1990. Nel seguito si analizzano disgiuntamente i temi, strettamente connessi, della produzione di energia e di riduzione delle emissioni in atmosfera. Evoluzione della normativa italiana in materia di produzione di energia Nell’agosto 1988 l’Italia vide approvato da parte del Consiglio dei Ministri il Piano Energetico Nazionale (P.E.N.), successivamente aggiornato nel 1991; esso enunciava i principi strategici e le soluzioni operative atte a soddisfare le esigenze energetiche del Paese fino all’anno 2000. Benché sottolineasse già temi ancor oggi di grande attualità, come il risparmio dell’energia, la protezione dell’ambiente, lo sviluppo delle fonti nazionali, la necessità di diversificare le fonti e le provenienze geopolitiche, la competitività del sistema produttivo, venne presto superato dagli accordi internazionali riassunti nel capitolo precedente. Alla luce dei cambiamenti avvenuti, a dieci anni dall'emanazione del PEN, il Governo convocò la Conferenza Nazionale Energia Ambiente con l'obiettivo di fare il punto sui risultati della politica energetica dal 1988 al 1998 e di avviare una nuova fase di attività in questo settore. La Conferenza si concluse con l'approvazione di un documento di sintesi delle scelte strategiche del Governo e delle Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 29 Relazione tecnica azioni da intraprendere per il futuro, demandando la loro applicazione ad una serie di accordi volontari tra le parti di volta in volta interessate. Con Deliberazione del 19 novembre 1998, n. 137, il Comitato Interministeriale per la Programmazione Economica (C.I.P.E.) individuò le “Linee guida per le politiche e misure nazionali di riduzione delle emissioni dei gas serra”, che, a seguito dell’emanazione della L. 1 giugno 2002, n. 120, “Modalità per la ratifica e l’esecuzione del Protocollo di Kyoto”, ed alla luce delle novità intervenute con le decisioni della Settima Conferenza delle Parti alla Convenzione Quadro sui Cambiamenti Climatici (COP7), è stata revisionata dal CIPE stesso con proprio atto del 19 dicembre 2002, n. 123, “Revisione delle linee guida per le politiche e misure nazionali di riduzione delle emissioni dei gas serra” (G.U. n. 68 del 22 marzo 2003). Fra le misure individuate dal CIPE nella Deliberazione 137/98 per la riduzione delle emissioni climalteranti, era compreso l’incremento della produzione di energia da fonti rinnovabili. La Deliberazione 123/2002, prendendo atto dell’andamento di crescita delle emissioni di gas serra rispetto ai valori del 1990, che ancora oggi si registra in Italia, introduce ulteriori misure di riduzione delle emissioni, fra cui proprio un maggior ricorso alle fonti rinnovabili. È del novembre 1998 il "Patto per l'energia e l'ambiente", frutto di un programma di lavoro promosso e coordinato dalla Conferenza Nazionale Energia e Ambiente, in rapporto con i Ministeri dell'Industria, dell'Ambiente, della Ricerca Scientifica, con la Conferenza dei Presidenti delle Regioni e con l'ENEA, coinvolgendo 32 organizzazioni interessate al rapporto energia ed ambiente, espressione del mondo imprenditoriale, finanziario, del lavoro, dell'ambientalismo, dei consumatori e delle istituzioni territoriali. Piano Energetico Ambientale Regionale La Regione Piemonte ha approvato con deliberazione del Consiglio Regionale 3 febbraio 2004, n. 351-3642 il “Piano Regionale Energetico Ambientale”, che pone tra i suoi obiettivi la trattazione e la regolamentazione delle fonti rinnovabili e dell’innovazione tecnologica, la razionalizzazione della produzione di energia, la razionalizzazione dei consumi di energia. Nello specifico della produzione di energia idroelettrica il Piano privilegia le tipologie impiantistiche di piccola taglia collocate all’interno di sistemi idrici ad uso plurimo e in generale ad impianti con capacità di regolazione almeno giornaliera, prevedendo contestualmente la dismissione degli impianti meno efficienti e meno compatibili con le esigenze di tutela dell’ambiente idrico. Il Piano stima un incremento del settore idroelettrico al 2010 in Piemonte pari a 150 MW in termini di nuovi impianti. Attualità sul tema ”energia” La proposta progettuale in esame sul torrente Corsaglia avviene in un momento di grande sensibilità da parte dell’opinione pubblica sulle tematiche ambientali e di risparmio energetico, tant’è vero che negli ultimi tempi quasi quotidianamente è possibile leggere sui giornali o assistere a servizi giornalistici inerenti questi temi, pungolati da un serrato susseguirsi di avvenimenti, che brevemente sono di seguito riassunti. Tralasciando nello specifico gli accadimenti degli ultimi periodi, preme in questa sede sottolineare come il susseguirsi frenetico di norme e leggi a livello nazionale ed internazionale renda necessario, in particolare in Italia, attuare rapidamente gli interventi per il ricorso massiccio alle fonti di energia rinnovabili e tra queste l’interesse per l’idroelettrico, in un territorio come quello italiano, è certamente grande. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 30 Relazione tecnica 4. MOTIVAZIONI ALLA BASE DELLA SCELTA PROGETTUALE Sulla base di tutto quanto emerso dal punto di vista normativo, pianificatorio e programmatico, affermare la coerenza dell’opera con la pianificazione e la programmazione territoriale e di settore, infatti: Il concessionario dell’impianto idroelettrico società “OLIVERO ENERGIA”, rappresentata dal Sig. Olivero Pietro Osvaldo sottoporrà il progetto di realizzazione di impianto idroelettrico alla Procedura di Impatto Ambientale, ai sensi dell’art. 12 della L.R. 40/1998 e della L. 152/2006 al fine di giungere a scelte progettuali condivise con le Amministrazioni Pubbliche che governano il territorio d’indagine; il progetto rispetta i principali adempimenti normativi in merito alla presenza di vincoli presso l'area oggetto di intervento, identificabili con il vincolo ambientale e paesaggistico (D.Lgs. n. 42/2004) e con il vincolo idrogeologico (L.R. 45/89); il progetto rispetta le indicazioni del P.T.R. in merito ai caratteri territoriali paesistici rinvenibili presso l’area di intervento (Sistema del verde, Centri storici, Corsi d’acqua principali) e risulta conforme agli Indirizzi di governo del territorio nello stesso contenuti (Zone di ricarica delle falde, centri turistici); il progetto è conforme a molti degli obiettivi dei progetti strategici individuati dal P.T.C.P. ed in particolare risulta perfettamente congruente col progetto “E.10. - politiche energetiche” avente come obiettivi la riduzione delle emissioni in atmosfera e lo sviluppo di un sistema energetico provinciale meno vulnerabile ed in grado di favorire lo sviluppo economico e l’occupazione a livello locale; il progetto è compatibile con le politiche di riqualificazione territoriale e sviluppo sostenibile perseguite dalla “Comunità Montana Alto Tanaro, Cebano e Monregalese”, a cui appartengono i comuni di Lesegno e San Michele M.vì. il progetto rispetta gli obiettivi di riduzione del rischio idrogeologico e di tutela della qualità delle acque e degli ambienti fluviali e risulta compatibile con le misure e le linee di intervento riportati nella pianificazione idrica (P.A.I., P.D.R.I., P.T.A.); il progetto è compatibile con le prescrizioni dei P.R.G.C. di Lesegno e san Michele M.vì, i quali consentono la realizzazione di interventi analoghi all’opera in progetto purché siano verificate le condizioni di fattibilità del medesimo; il progetto non presenta incompatibilità in merito rispetto ai Piani di Zonizzazione Acustica comunali. come sarà specificato nei capitoli che seguono, esistono anche motivazioni di carattere più tecnico nonché valutazioni economiche (i.e. bilancio costi-benefici) a favore della soluzione proposta dal presente progetto. Il progetto idroelettrico è di tipo puntuale e pertanto non presenta alcun tratto sotteso e dunque è altamente compatibile con l’ambiente circostante come dimostrato dagli studi e dai monitoraggi ante operam effettuati. Il progetto valorizza energeticamente una traversa esistente a scopo irriguo, dove viene migliorato il salto idraulico mediante sovrastante sbarramento mobile e inserito un impianto direttamente nel corpo della traversa stessa. I principali punti di carattere progettuale che riguardano la scelta del sito sono: la morfologia del tratto di alveo interessato dal progetto unitamente alle caratteristiche idrauliche ed idrologiche della stessa asta torrentizia nel tratto in esame fanno sì che l’intervento abbia un buon rapporto benefici/costi soprattutto dal punto di vista ambientale, infatti gli impatti sono minimi in quanto non c’è sottrazione di acqua dal corso d’acqua e tratto sotteso perché l’impianto è puntuale e anche i costi sono piuttosto ridotti perché l’impianto è molto compatto e circoscritto nell’intorno della sponda destra orografica a lato della traversa esistente; l’impatto principale è limitato alla sola fase di cantiere. E’ doveroso precisare che sono previsti criteri di costruzione e opere di ripristino tali da non pregiudicare la condizione dei terreni attraversati. La sponda destra orografica non è esondabile e nel contempo si presenta nella zona poco acclive quindi si riesce a realizzare il fabbricato della centrale di produzione sulla sponda destra totalmente interrato con posizionamento della turbina al di sotto del piano di campagna. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 31 Relazione tecnica - 5. L’unico fabbricato emergente è il locale Enel con quadri le cui caratteristiche architettoniche sono conformi con le tipologie costruttive locali. ELENCO ELABORATI Il progetto di derivazione idroelettrica sul torrente Corsaglia è redatto con un livello di definizione e approfondimento assimilabile al Progetto definitivo prescritto dalla Legge 109/94 e s.m.i. per lavori pubblici similari; nella seguente tabella sono elencati gli elaborati di progetto la cui definizione di dettaglio è stata possibile attraverso un continuo raffronto con le risultanze delle indagini condotte attraverso gli elaborati progettuali. Gli elaborati del Progetto sono elencati nel seguente prospetto. Corrisponde nza elaborati R.R. 10/R A1 A2 A3 A4 A6 A6 A5 A5 A8 A11 A7 A10 A9 A7 Num 1 2 3 4 5 6 7 8 9 10 11 12.1 12.2 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 S1 - Elaborato Sintesi non tecnica Relazione tecnica Relazione idrologica Corografia con individuazione del bacino idrografico Planimetria su Carta Tecnica Regionale Planimetria catastale Planimetria esistente Planimetria in progetto Planimetria particolareggiata esistente Planimetria particolareggiata in progetto Piante e sezioni degli interventi Locale ENEL e trasformatori Preventivo di connessione Sezioni del Torrente Corsaglia Profilo longitudinale del Torrente Corsaglia Planimetria di cantiere Progetto di compensazione Cronoprogramma dei lavori Piano di gestione e manutenzione delle opere Piano di dismissione delle opere Piano finanziario delle opere progettate Documentazione fotografica Relazione geologica Compatibilità ambientale del prelievo Compatibilità con il PAI Fascicolo sui dispositivi di misura Compatibilità con il PdGPo Relazione ittiologica Caratterizzazione delle componenti biotiche e abiotiche dell’ecosistema acquatico e valutazione degli impatti Piano di monitoraggio ambientale Fascicolo dello sbarramento Relazione Acustica SIA - Relazione Scheda del catasto delle derivazioni idriche Attestazione di credito Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Scala 1:20.000 1:5.000 1:2.000 1:1000 1:1000 1:200 1:200 1:100 1:100 1:500 1:2000 / 1:200 32 Relazione tecnica 6. COORDINATE UTM DELL’IMPIANTO Le coordinate UTM dell’impianto in progetto sono le seguenti: • Opera di presa: Est 415824 – Nord 4916313 • Opera di restituzione: Est 415841 – Nord 4916315 7. SCELTA PROGETTUALE E IPOTESI PROGETTUALI ALTERNATIVE 7.1. Analisi delle alternative progettuali e scelta della soluzione in esame Durante l’iter progettuale sono state prese in considerazione diverse soluzioni tra cui la non realizzazione dell’opera (ipotesi ZERO. Qualora l’opera non venisse realizzata (IPOTESI ZERO) e si mantenesse invariata l’attuale conformazione dell’area in esame, non si determinerebbero certamente impatti negativi, ma si rinuncerebbe ai vantaggi dell’intervento, tra i quali: il soddisfacimento di una domanda di energia crescente con produzione di energia mediante ricorso a fonti rinnovabili e metodologie meno inquinanti di quelle attualmente comunemente impiegate. L’ipotesi ZERO, dunque, va considerata e valutata non tanto come alternativa alla realizzazione dell’impianto, quanto piuttosto come termine di confronto rispetto ai diversi scenari ipotizzabili per la costruzione dello stesso. Tra le numerose opzioni è stata scelta quella che permette il miglior compromesso tra impatto ambientale e paesaggistico, realizzabilità tecnica e tornaconto economico. In fase progettuale si è valutata la possibilità di localizzare l’impianto in altre sezioni, ritenute poi meno vantaggiose. Di seguito si riporta una descrizione dettagliata delle alternative prese in considerazione e delle valutazioni tecniche, economiche ed ambientali che hanno condizionato la scelta definitiva. Come già detto durante la fase di studio sono state fatte varie alternative progettuali prima di giungere alla soluzione adottata. Sulla base del rilievo topografico sono state valutate ipotesi tipologicamente diverse su entrambe le sponde del torrente Corsaglia. Punto di partenza dello studio è l’utilizzo dell’asta del Corsaglia nel rispetto del contesto ambientale considerata la presenza di altri impianti idroelettrici nella zona. Nel seguito si riporta una breve descrizione delle ipotesi progettuali alternative vagliate in fase di studio e successivamente quella adottata per il presente progetto. 7.2. Soluzione alternativa A Impianto con presa in sponda sinistra e restituzione a valle di Cascina San Gervasio Elementi progettuali della soluzione analizzata - Utilizzo della traversa esistente - Opera di presa in sponda sinistra orografica Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 33 Relazione tecnica - Condotta di adduzione interrata sulla prosecuzione dell’opera di presa fino all’edificio della centrale - Locale turbine a valle di cascina San Gervasio - Restituzione nel torrente Corsaglia mediante canale interrato sempre in sponda sinistra orografica - Produzione annua stimata in 2,5 GWh con un salto idraulico di circa 6,00 m. Figura 1: Soluzione alternativa A CONCLUSIONI La soluzione alternativa A ipotizza un impianto con un tratto sotteso pari a circa 850 m, con una produzione presunta di circa 2,5 GWh ed un salto idraulico di circa 6,00 m, il canale di adduzione in sponda sinistra è difficilmente realizzabile in quanto la sponda è particolarmente scoscesa, le dimensioni dello stesso canale impediscono di fatto l’utilizzo del canale irriguo esistente in quanto dimensionato per adduzioni nell’ordine di poche centinaia di litri. L’opera di presa e la prima parte di canale di adduzione (circa 200 m), oltre a essere in “battuta” in caso di fenomeni di piena ordinaria, risultano anche in zona totalmente esondabile, l’impianto (per la parte iniziale) insiste nella stessa posizione dell’attuale presa irrigua che deve rimanere in funzione. La presenza di un notevole tratto sotteso e la produzione annua stimata non particolarmente elevata non giustificano sia a livello ambientale, che di rapporto costi/ricavi la realizzazione di un impianto in linea, la conclusione è che quindi risulta più opportuna la progettazione di un impianto di tipo puntuale. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 34 Relazione tecnica 7.3. Soluzioni alternative B Soluzione B1 - Impianto puntuale con presa in sponda sinistra orografica Elementi progettuali della soluzione analizzata Utilizzo della traversa esistente Opera di presa in sponda sinistra orografica Locale turbine in corrispondenza della traversa esistente Restituzione nel torrente Corsaglia mediante canale interrato sempre in sponda sinistra orografica - Produzione annua stimata in 1,3 GWh con un salto idraulico di circa 3,00 m. - Figura 2: Soluzioni alternative B CONCLUSIONI La soluzione alternativa B1 ipotizza un impianto praticamente privo di tratto sotteso, con una produzione presunta di circa 1,2 GWh ed un salto idraulico di circa 3,00 m, il canale di adduzione in sponda sinistra è difficilmente realizzabile in quanto la sponda è particolarmente scoscesa. L’intero impianto risulta essere in “battuta” in caso di fenomeni di piena ordinaria, e in zona totalmente esondabile, l’impianto insiste nella stessa posizione dell’attuale presa irrigua che deve rimanere in funzione. La stessa realizzazione dell’impianto risulta tecnicamente di difficile costruzione visti gli esigui spazi a disposizione e la notevole inclinazione della sponda sinistra nel tratto in esame. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 35 Relazione tecnica Soluzione B2 - Impianto puntuale con presa in sponda sinistra orografica e innalzamento della traversa esistente tramite uno sbarramento mobile gonfiabile Elementi progettuali della soluzione analizzata - Utilizzo della traversa esistente con innalzamento della stessa tramite sbarramento mobile gonfiabile per un salto totale di circa 5 m - Opera di presa in sponda sinistra orografica - Locale turbine in corrispondenza della traversa esistente - Restituzione nel torrente Corsaglia mediante canale interrato sempre in sponda sinistra orografica - Produzione annua stimata in 2,1 GWh con un salto idraulico di circa 5,00 m. CONCLUSIONI La soluzione alternativa B2 ipotizza un impianto praticamente privo di tratto sotteso, con una produzione presunta di circa 2,1 GWh ed un salto idraulico di circa 5,00 m, il canale di adduzione in sponda sinistra è difficilmente realizzabile in quanto la sponda è particolarmente scoscesa. L’intero impianto risulta essere in “battuta” in caso di fenomeni di piena ordinaria, e in zona totalmente esondabile, l’impianto insiste nella stessa posizione dell’attuale presa irrigua che deve rimanere in funzione. La stessa realizzazione dell’impianto risulta tecnicamente di difficile costruzione visti gli esigui spazi a disposizione e la notevole inclinazione della sponda sinistra nel tratto in esame. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 36 Relazione tecnica 7.4. Soluzione adottata Impianto puntuale con presa in sponda destra orografica e innalzamento della traversa esistente tramite uno sbarramento mobile gonfiabile Elementi progettuali della soluzione adottata - Utilizzo della traversa esistente con innalzamento della stessa tramite sbarramento mobile gonfiabile per un salto totale di circa 5 m - Opera di presa in sponda destra orografica - Locale turbine in corrispondenza della traversa esistente - Restituzione nel torrente Corsaglia mediante canale interrato sempre in sponda destra orografica - Produzione annua stimata in 2,1 GWh con un salto idraulico di circa 5,00 m. CONCLUSIONI La soluzione adottata ipotizza un impianto privo di tratto sotteso, con una produzione presunta di circa 2,1 GWh ed un salto idraulico di circa 5,00 m, l’impianto in sponda destra è agevolmente realizzabile, visto che la sponda non presenta problematiche di tipo alluvionale né geomorfologico. L’impianto non incide sulla presa irrigua esistente. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 37 Relazione tecnica 8. DESCRIZIONE GENERALE DELL’IMPIANTO Per una migliore consultazione del progetto, nel presente paragrafo si riporta una sintesi degli elementi dimensionali e tecnici relativi alle opere previste e si rimanda ai successivi capitoli per gli approfondimenti tecnici. Il Progetto prevede la realizzazione di un nuovo impianto idroelettrico ad acqua fluente, costituito da opera di presa posta in sponda destra del Torrente Corsaglia in corrispondenza della traversa esistente della derivazione irrigua San Gervasio. L’impianto, di tipo puntuale, è abbinato ad un impianto secondario volto alla valorizzazione del DMV. L’adeguamento della traversa, la cui quota attuale è mediamente di 372.95m slm prevede l’innalzamento della stessa mediante la realizzazione di uno sbarramento gonfiabile tale da sopraelevare complessivamente il livello idrico a monte di due metri. Tale altezza è stata attentamente valutata analizzando la geometria e la natura della sponde a monte della traversa e suffragata da verifiche idrauliche mirate. La struttura si costituisce di due elementi: uno fisso, il cui coronamento è previsto a quota 372.95m slm oltre un cordolo di 30 cm ed uno mobile ovvero uno sbarramento gonfiabile scudato ovvero paratoie metalliche a ventola azionate da un gommone capace di gestirne con sicurezza l’innalzamento e l’abbattimento La traversa è completata con scarico di fondo e passaggio artificiale per l’ittiofauna. L’opera di derivazione è prevista in sponda destra, mediante un manufatto in cls delle dimensioni utili di 6,0 x 1,7 metri ed è dotata di paratoia a ventola, paratronchi e, sul successivo canale di adduzione, di sghiaiatore e impianto sgrigliatore. Il canale si costituisce di due parti, il primo a cielo aperto, circa 17metri, e il secondo coperto, circa 12 metri. La turbina, Kaplan ad asse verticale, è posta entro un fabbricato completamente interrato delle dimensioni di 6,5 x 6,0 metri ed è capace di governare una portata massima di 10,000 m3/s. La restituzione avviene mediante un canale coperto a circa 18 metri dall’esistente traversa. È inoltre previsto un impianto secondario per il rilascio la valorizzazione energetica del DMV. L’opera è realizzata entro il coro traversa e si costituisce essenzialmente di una vasca in c.a. di contenute dimensioni. La sezione di presa è delle dimensioni 3,5 x 1,7 metri ed è anch’esso dotato di una paratoia a ventola e di impianto sgrigliatore La turbina, Kaplan a bulbo e ad asse verticale, è posta in camera libera entro una vasca coperta posta immediatamente a valle dello sgrigliatore ed è capace di governare una portata massima di 4,000 m3/s. La restituzione in questo caso avviene immediatamente al piede della traversa. La connessione alla rete ENEL è prevista mediante la realizzazione di un basso fabbricato, posto in posizione esterna alla fascia di vincolo Ee, capace di ospitare: i trasformatori, i quadri comandi e i locali ENEL. Si prevede per il tratto privato la realizzazione di elettrodotti interrati; per la parte ENEL, come da preventivo di connessione, un primo tratto interrato su strada sterrata quindi una line aera, ricalcante un tracciato dismesso, sino ad una cabina esistente posta a lato della S.S. 28 sud. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 38 Relazione tecnica Le caratteristiche del prelievo risultano: portata massima derivabile portata derivata media portata derivata minima DMV di base (Torrente Corsaglia) Il bacino imbrifero del torrente Corsaglia sotteso morfologici principali: superficie altitudine massima altitudine minima (sezione di presa) Le principali - = 14,000 m³/s; = 5,851 m³/s; = 0,600 m³/s; = 0,640 m³/s. alla sezione di presa possiede i seguenti parametri = 233,6 km2; = 2631,4 m s.l.m. (monte Mongioie); = 373 m s.l.m; caratteristiche tecniche e dimensionali dell’impianto sono: portata derivata media = 5,851 m³/s; salto nominale = 4,95 m; producibilità media = 2,1 GWh/anno. Il progetto prevede la realizzazione delle seguenti opere: interventi sulla traversa esistente: • realizzazione struttura di fondazione fissa a monte della traversa esistente a quota 372,95 m s.l.m. • installazione di sbarramento gonfiabile flessibile con paratie metalliche di protezione con elemento fisso a quota 373,25m s.l.m. e porzione mobile (abbattibile) a quota 374,95m s.l.m. ovvero con altezza utile di 1,70 m; • realizzazione di scarico di fondo e passaggio artificiale per l’ittiofauna e di una platea in massi a valle dell’opera esistente e quota 368,70m s.l.m. • realizzazione di impianto idroelettrico nel corpo traversa per valorizzazione DMV con turbina kaplan a bulbo con soglia di derivazione posta a quota 373,25m s.l.m. della larghezza di 3,50m • realizzazione di opere di gestione a tutela della derivazione irrigua San Gervasio opera di presa sul Torrente Corsaglia, costituita da: • soglia di derivazione posta a quota 373,25m s.l.m., in sponda destra orografica della larghezza di 6,00m. • canale di derivazione aperto, circa 17 metri, dotato di paratoie di gestione a ventola, sgrigliatore e sghiaiatore • canale di derivazione coperto, circa 12 metri, sino alla vasca di carico della centrale complesso centrale di produzione costituito da: • locale turbine - centrale idroelettrica costituita da un edificio interrato, a pianta rettangolare con dimensioni di 6,50 x 6,00 metri, avente struttura perimetrale in c.a. e solaio removibile per le operazioni di montaggio e manutenzione. opera di restituzione costituita da: • un canale interrato, avente pianta irregolare, di raccordo tra il diffusore e l’alveo del Torrente Corsaglia per uno sviluppo di circa 15 metri. • scogliere in massi a protezione della sponda. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 39 Relazione tecnica complesso gestione e connessione rete MT ENEL costituito da: • locale gestione / ENEL costituita da un basso fabbricato delle dimensioni complessive di 11,0 x 6,00 metri ripartito nei seguenti locali: - locale gestione - locale trasformatori - locale misure - locale ENEL Le pareti verranno intonacate, il tetto è previsto in legno posto al di sopra di un solaio il c.a. che lo isola dei sottostanti locali. • linea di connessione privata costituita da un cavidotto interrato di collegamento tra le turbine e il basso fabbricato; è prevista al di sotto della pista di accesso • linea di connessione ENEL costituita da un cavidotto di collegamento tra il basso fabbricato (locale ENEL) e la linea esistente presso la S.S. 28; è prevista per un primo tratto interrata sotto piste sterrate e successivamente aerea su pali sino ad una cabina esistente la soluzione tecnica è stata definita con preventivo di connessione T0651739 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 40 Relazione tecnica 9. CONSIDERAZIONI CIRCA IL BACINO ATTUALE E QUELLO CON INTERVENTO Si riportano alcuni dati tecnici relativi al bacino attuale dovuto alla presenza della traversa esistente e al bacino con la situazione in progetto. Invaso nella situazione esistente e nella situazione con progetto Il volume d’invaso è calcolato come somma dei volumi compresi tra sezioni successive. In particolare nel tratto compreso tra due sezioni il volume è definito come prodotto della distanza per la sezione idraulica media. Il volume è calcolato a partire dalla sezione in cui il livello di magra coincide con quello di progetto d’invaso (374,95 m s.l.m.). Infatti a monte il volume d’invaso è nullo, poiché il profilo di magra è più elevato di quello di rigurgito. La traversa fluviale in progetto è ubicata appena a valle della sezione 16. La Tabella 1 che segue riporta i risultati elaborati come indicato in precedenza. - Tabella 1: Volume di invaso Generico Rilievo - magra Progetto - rigurgito Dist. (m) Hmagra (m s.l.m.) (m2) Inizio Sezione 3 Sezione 4 Sezione 5 Sezione 6 Sezione 7 Sezione 8 Sezione 9 Sezione 10 84,15 120,89 117,66 133,19 69,47 81,18 58,04 58,58 375,13 374,72 374,37 373,90 373,15 373,06 373,02 372,98 372,99 Totale 723 Sezione Vmagra (m3) Hrigurgito (m s.l.m.) (m2) 5,06 4,80 4,85 4,23 3,33 8,29 10,25 8,32 60,20 415 583 534 503 404 753 539 2 007 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 5,06 9,93 18,90 33,51 61,03 116,99 85,22 88,73 245,98 631 1 743 3 083 6 296 6 184 8 208 5 048 9 804 8 5 738 57 40 995 magra rigurgito Vrigurgito (m3) Nel complesso, i volumi sono: Volume occupato dalla portata di magra nella condizione di rilievo Vmagra = 5˙738 m3 Volume di rigurgito della traversa nella condizione di progetto Vrigurgito = 40˙995 m3 Ne consegue che il volume d’invaso dello sbarramento in progetto è: - Vinvaso = Vrigurgito − Vmagra = 40 995 − 5 738 = 35 258 m 3 L’estensione dell’invaso nelle condizioni attuali è di circa 340 metri , il nuovo invaso si estenderà di ulteriori 350 metri a monte. Nella planimetria che segue viene riportata l’estensione dell’invaso attuale e l’invaso nella situazione di progetto. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 41 10 11-12.5 13 14 15 9 8 7 6 5 4 1 3 2 LEGENDA Limite invaso situazione esistente Limite invaso situazione in progetto Relazione tecnica 10. SINTESI IDROLOGICA Di seguito si riassumono le principali caratteristiche idrologiche del torrente Corsaglia riferite al bacino imbrifero dell’impianto idroelettrico in progetto nei comuni di Lesegno e di San Michele Mondovì. In particolare si riportano: portate medie portate e contributi specifici medi mensili ed annui dell’anno medio; - curva di durata delle portate curve di durata delle portate e dei contributi specifici dell’anno medio; - portate derivabili portate medie mensili ed annua derivate dall’impianto idroelettrico nell’anno medio. Per la stima delle portate e dei contributi specifici si è ricorso al metodo della similitudine idrologica, sulla base dei dati di portata misurati nello stesso torrente Corsaglia nella stazione idrometrica dell’ARPA Piemonte a Torre Mondovì. L’analisi idrologica dettagliata propedeutica ai risultati riassunti nel presente capitolo è contenuta nell’elaborato 3 “Relazione idrologica”. Nei paragrafi 10.4, 10.5, 10,6 è riportata una Sintesi dell’ Analisi idrologica alternativa (richiesta dall’Ufficio Acque della Provincia di Cuneo). Si riportata la sintesi dell’analisi idrologica delle portate dell’anno medio secondo le indicazioni della relazione di istruttoria della fase di Verica di assoggettabilità alla Valutazione di Impatto Ambientale. L’analisi idrologica è basata sule portate misurate nelle stazioni di misura del SIMN e dell’ARPA Piemonte indicate nella successiva tabella, nella stessa tabella sono anche riportate le caratteristiche dei bacini idrografici delle stazioni idrometriche sopraccitate. Tabella 2: Dati caratteristici dei bacini idrografici Gestore Torrente SIMN Corsaglia ARPA Piemonte Corsaglia Località Centrale Moline Torre Mondovì Periodo di misura 1931 ÷ 1959 2008 ÷ 2013 Nell’appendice sono definite sia le portate disponibili sia quelle derivabili sulla base della nuova analisi idrologica. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 43 Relazione tecnica 10.1. Portate medie La Tabella 3 ed il Grafico 1 riassumono le portate ed i contributi specifici medi mensili ed annui stimati alla sezione di presa della centrale idroelettrica in progetto. L’elaborazione delle portate è stata condotta con la metodologia anzi detta. Tabella 3: Portate e contributi specifici medi mensili ed annuo del torrente Corsaglia nella sezione della presa in progetto Periodo Anno Gen Feb 2 Mar Apr Mag Giu Lug Ago Set Ott Nov Dic q (l/s km ) 31,61 14,53 16,94 48,20 79,62 68,21 33,97 10,59 6,15 7,80 9,84 63,53 20,50 3 7,384 3,394 3,95711,26018,59815,933 7,936 2,4741,437 1,821 2,30014,841 4,789 Q (m /s) Grafico 1: Portate medie mensili del torrente Corsaglia nella sezione della presa in progetto Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 44 Relazione tecnica 10.2. Curva di durata delle portate La curva di durata delle portate torrente Corsaglia nella sezione di presa in progetto è stata determinata con lo stesso procedimento utilizzato per le portate medie mensili ed annua. Tabella 4: Curva di durata delle portate del torrente Corsaglia nella sezione di presa in progetto Durata (gg) 2 q (l/s km ) Q (m3/s) 10 123,87 28,936 30 81,96 19,147 60 55,43 12,948 91 38,42 8,976 135 24,59 5,744 182 17,19 4,015 274 8,26 1,929 355 3,93 0,917 Minimo 0,05 0,011 Grafico 2: Curva di durata delle portate del torrente Corsaglia nella sezione di presa in progetto Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 45 Relazione tecnica 10.3. Portate derivabili A monte della presa dell’impianto idroelettrico in progetto non sono presenti derivazioni significative in grado di modificare sostanzialmente la portata del torrente Corsaglia, così le portate disponibili sono quelle totali definite in precedenza, senza correzioni. In corrispondenza dello sbarramento fluviale oggetto della valorizzazione energetica in progetto è presente la presa del Consorzio Irriguo San Gervasio. L’utenza irrigua deriva la portata media di 0,050 m3/s e quella massima di 0,060 m3/s nel periodo compreso tra il 1 maggio ed il 30 settembre di ogni anno. Alla derivazione irrigua è assicurata la precedenza di prelievo, pertanto la portata del torrente Corsaglia disponibile per l’impianto idroelettrico in progetto è quella totale precedentemente definita sottratta della derivazione ad uso agricolo (mediamente 0,050 m3/s). Il tratto sotteso dall’impianto idroelettrico in progetto è limitato alla sola estensione dello sbarramento fluviale, pertanto non sono presenti derivazioni intermedia a cui assicurare la disponibilità idrica. L’impianto idroelettrico in progetto, inoltre, è dotato di turbina collocata nel corpo traversa per la valorizzazione energetica del deflusso minimo vitale, di conseguenza il rilascio è limitato alla sola portata di alimentazione del passaggio artificiale per l’ittiofauna (0,128 m3/s). L’intervallo di portate derivabili dall’impianto idroelettrico in progetto è: 3 Qmax = 14,000 m /s portata massima d’esercizio; 3 Qmin = 0,600 m /s portata minima d’esercizio. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 46 Relazione tecnica Dall’analisi delle curve mensili di durata delle portate si sono ricavati i valori medi mensili ed annui di deflusso. Tabella 5: Portate medie mensili ed annua Periodo Portata totale (m 3/s) Portata irrigua (m 3/s) Portata disponibile (m 3/s) Portata derivata (m 3/s) Portata rilasciata (m 3/s) Rapporto Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov Dic 3,394 3,910 11,260 18,598 15,933 7,936 2,474 1,437 1,821 2,300 14,841 4,789 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 3,394 3,910 11,260 18,598 15,883 7,886 2,424 1,387 1,771 2,300 14,841 4,789 3,266 3,782 9,823 13,030 12,713 7,681 2,296 1,259 1,587 2,108 8,034 4,661 0,128 0,128 1,437 5,568 3,170 0,205 0,128 0,128 0,184 0,191 6,808 0,128 96% 97% 87% 70% 80% 97% 93% 88% 87% 92% 54% 97% Anno 7,382 0,021 7,361 5,851 1,510 79% Grafico 3: Portate medie mensili Nell’anno medio l’impianto deriva la portata massima d’esercizio 51 gg/anno e per 311 gg/anno la centrale produce energia idroelettrica con portate comprese tra quella minima e quella massima d’esercizio. Quindi la centrale idroelettrica in progetto rimane mediamente inattiva per 3 gg/anno. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 47 Relazione tecnica Nella seguente Tabella 6 si riportano le curve mensili di durata delle portate derivabili dall'impianto idroelettrico in progetto, desunte col metodo precedentemente indicato. 3 Tabella 6: Curve di durata della portata derivabile (m /s) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Media Gen Feb 5,190 4,852 4,432 4,232 4,131 4,032 3,915 3,827 3,741 3,704 3,549 3,315 3,248 3,185 3,140 3,089 3,022 2,946 2,878 2,858 2,751 2,677 2,626 2,600 2,565 2,537 2,520 2,486 2,464 2,410 2,326 3,266 6,510 5,976 5,670 5,207 4,703 4,488 4,385 4,292 4,111 3,984 3,883 3,758 3,646 3,567 3,371 3,289 3,196 3,168 3,136 3,076 3,011 2,916 2,884 2,832 2,763 2,742 2,695 2,639 Mar 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,821 12,207 11,281 10,176 9,705 9,431 9,143 8,983 8,641 8,372 7,711 7,328 7,026 6,688 6,508 6,299 6,142 5,984 5,937 5,842 5,726 5,558 3,782 9,823 Apr 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,884 13,386 12,876 12,697 12,290 11,985 11,660 11,427 11,218 11,061 10,669 9,991 9,767 Mag 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,976 13,425 13,115 12,955 12,800 12,617 12,477 12,144 11,958 11,679 11,498 10,303 9,407 9,061 8,673 8,016 13,030 12,713 Giu 14,000 14,000 12,917 11,907 11,293 10,740 10,509 9,997 9,095 8,501 8,307 8,111 7,947 7,784 7,485 7,364 7,286 6,979 6,378 5,926 5,512 5,118 4,718 4,569 4,330 4,208 4,057 3,936 3,801 3,654 Lug 4,274 3,943 3,768 3,486 3,364 3,191 3,088 2,735 2,630 2,567 2,533 2,431 2,326 2,259 2,182 2,128 2,076 2,003 1,934 1,869 1,770 1,745 1,682 1,626 1,499 1,465 1,413 1,374 1,327 1,290 1,191 7,681 2,296 Ago Set 3,452 2,522 1,745 1,648 1,585 1,536 1,501 1,445 1,361 1,331 1,288 1,252 1,213 1,185 1,150 1,120 1,103 1,094 1,060 1,043 1,010 0,972 0,948 0,924 0,901 0,890 0,864 0,821 0,741 0,688 0,623 1,259 8,126 6,595 4,270 2,679 2,044 1,897 1,798 1,714 1,579 1,452 1,424 1,336 1,267 1,217 1,159 0,978 0,907 0,847 0,827 0,795 0,739 0,705 0,685 0,653 0,649 0,640 0,625 0,000 0,000 0,000 Ott 14,000 5,756 4,100 3,119 2,867 2,712 2,507 2,083 2,023 1,913 1,590 1,521 1,398 1,381 1,323 1,276 1,263 1,259 1,237 1,207 1,190 1,114 1,067 1,037 1,004 0,998 0,976 0,948 0,873 0,828 0,785 1,587 2,108 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Nov Dic 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,884 11,582 10,221 8,945 8,256 7,873 7,276 6,886 6,337 6,075 5,931 5,720 5,263 4,951 4,619 4,430 4,212 4,083 3,941 3,806 3,018 2,908 2,791 13,617 9,739 7,894 7,289 6,475 6,163 5,554 5,289 5,145 4,962 4,714 4,613 4,538 4,318 4,167 4,036 3,898 3,584 3,470 3,300 3,280 3,229 3,132 3,058 2,916 2,847 2,819 2,731 2,641 2,568 2,520 8,034 4,661 48 Relazione tecnica 10.4. Portate medie con Analisi idrologica alternativa La Tabella 7 ed il Grafico 4 riassumono le portate ed i contributi specifici medi mensili ed annui stimati alla sezione di presa della centrale idroelettrica in progetto. L’elaborazione delle portate è stata condotta con la metodologia anzi detta. Tabella 7: Portate e contributi specifici medi mensili ed annuo del torrente Corsaglia nella sezione della presa in progetto, con Analisi idrologica alternativa Periodo Anno Gen Feb 2 Mar Apr Mag Giu Lug Ago Set Ott Nov Dic q (l/s km ) 33,46 11,67 14,34 33,32 71,18 93,93 51,57 17,90 9,76 15,65 26,40 37,61 17,71 3 7,817 2,725 3,350 7,784 16,628 21,943 12,0474,182 2,281 3,656 6,167 8,786 4,137 Q (m /s) Grafico 4: Portate medie mensili del torrente Corsaglia nella sezione della presa in progetto, con Analisi idrologica alternativa Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 49 Relazione tecnica 10.5. Curva di durata delle portate con Analisi idrologica alternativa La curva di durata delle portate torrente Corsaglia nella sezione di presa in progetto è stata determinata con lo stesso procedimento utilizzato per le portate medie mensili ed annua. Tabella 8: Curva di durata delle portate del torrente Corsaglia nella sezione di presa in progetto con Analisi idrologica alternativa Durata (gg) 10 91 182 274 355 Minima 2 q (l/s km ) 126,37 44,05 17,17 9,45 5,74 0,05 3 Q (m /s) 29,521 10,291 4,011 2,208 1,341 0,011 Grafico 5: Curva di durata delle portate del torrente Corsaglia nella sezione di presa in progetto, con Analisi idrologica alternativa Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 50 Relazione tecnica 10.6. Portate derivabili con Analisi idrologica alternativa A monte della presa dell’impianto idroelettrico in progetto non sono presenti derivazioni significative in grado di modificare sostanzialmente la portata del torrente Corsaglia, così le portate disponibili sono quelle totali definite in precedenza, senza correzioni. In corrispondenza dello sbarramento fluviale oggetto della valorizzazione energetica in progetto è presente la presa del Consorzio Irriguo San Gervasio. L’utenza irrigua deriva la portata media di 0,050 m3/s e quella massima di 0,060 m3/s nel periodo compreso tra il 1 maggio ed il 30 settembre di ogni anno. Alla derivazione irrigua è assicurata la precedenza di prelievo, pertanto la portata del torrente Corsaglia disponibile per l’impianto idroelettrico in progetto è quella totale precedentemente definita 3 sottratta della derivazione ad uso agricolo (mediamente 0,050 m /s). Il tratto sotteso dall’impianto idroelettrico in progetto è limitato alla sola estensione dello sbarramento fluviale, pertanto non sono presenti derivazioni intermedia a cui assicurare la disponibilità idrica. L’impianto idroelettrico in progetto, inoltre, è dotato di turbina collocata nel corpo traversa per la valorizzazione energetica del deflusso minimo vitale, di conseguenza il rilascio è limitato alla sola 3 portata di alimentazione del passaggio artificiale per l’ittiofauna (0,128 m /s). L’intervallo di portate derivabili dall’impianto idroelettrico in progetto è: Qmax = 14,000 m3/sportata massima d’esercizio; Qmin = 0,600 m3/s portata minima d’esercizio. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 51 Relazione tecnica Dall’analisi delle curve mensili di durata delle portate si sono ricavati i valori medi mensili ed annui di deflusso. Tabella 9: Portate medie mensili ed annua con Analisi idrologica alternativa Periodo Portata totale (m3/s) Portata irrigua (m3/s) Portata Portata disponibile derivata (m3/s) (m3/s) Portata rilasciata (m3/s) Rapporto Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov Dic 2,725 3,350 7,784 16,628 21,943 12,047 4,182 2,281 3,656 6,167 8,786 4,137 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 0,050 2,725 3,350 7,784 16,628 21,893 11,997 4,132 2,231 3,606 6,167 8,786 4,137 2,597 3,222 7,455 12,958 13,845 10,829 4,004 2,103 3,266 5,312 6,732 4,009 0,128 0,128 0,328 3,669 8,047 1,168 0,128 0,128 0,341 0,855 2,054 0,128 95% 96% 96% 78% 63% 90% 96% 92% 89% 86% 77% 97% Anno 7,817 0,021 7,796 6,364 1,432 82% Grafico 6: Portate medie mensili con Analisi idrologica alternativa Nell’anno medio l’impianto deriva la portata massima d’esercizio 63 gg/anno e per i restanti 302 gg/anno la centrale produce energia idroelettrica con portate comprese tra quella minima e quella massima d’esercizio. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 52 Relazione tecnica Nella seguente Tabella 10 si riportano le curve mensili di durata delle portate derivabili dall'impianto idroelettrico in progetto, desunte col metodo precedentemente indicato. Tabella 10: Curve di durata della portata derivabile (m3/s) con Analisi idrologica alternativa Durata Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov (gg) 1 4,106 6,007 14,000 14,000 14,000 14,000 12,126 5,252 14,000 14,000 14,000 2 3,763 5,413 14,000 14,000 14,000 14,000 8,394 4,036 11,938 14,000 14,000 3 3,450 5,077 14,000 14,000 14,000 14,000 7,157 3,211 9,065 12,825 14,000 4 3,345 4,617 13,137 14,000 14,000 14,000 6,440 2,989 6,681 10,538 14,000 5 3,228 4,208 12,289 14,000 14,000 14,000 5,868 2,824 5,204 9,095 14,000 6 3,119 4,012 11,826 14,000 14,000 14,000 5,518 2,600 4,393 7,897 12,838 7 3,021 3,921 11,088 14,000 14,000 14,000 5,213 2,496 3,798 7,274 11,208 8 2,945 3,709 9,919 14,000 14,000 14,000 4,946 2,364 3,495 6,570 9,895 9 2,891 3,541 9,365 14,000 14,000 13,841 4,684 2,244 3,115 6,020 8,577 10 2,818 3,422 8,994 14,000 14,000 13,286 4,491 2,165 2,869 5,763 7,671 11 2,728 3,342 8,545 14,000 14,000 12,985 4,224 2,063 2,628 5,433 6,769 12 2,612 3,234 8,077 14,000 14,000 12,476 4,034 1,987 2,462 5,181 6,229 13 2,555 3,145 7,729 14,000 14,000 12,010 3,850 1,977 2,302 4,888 5,812 14 2,533 3,071 7,291 14,000 14,000 11,672 3,705 1,909 2,117 4,566 5,437 15 2,470 2,966 7,063 14,000 14,000 11,237 3,568 1,874 2,025 4,231 5,149 16 2,430 2,871 6,719 14,000 14,000 10,914 3,418 1,838 1,884 4,015 4,840 17 2,412 2,759 6,488 14,000 14,000 10,651 3,278 1,800 1,805 3,945 4,589 18 2,392 2,655 6,227 13,767 14,000 10,343 3,055 1,767 1,743 3,706 4,343 19 2,334 2,514 5,795 13,417 14,000 9,869 2,941 1,742 1,697 3,598 4,147 20 2,272 2,440 5,370 13,012 14,000 9,524 2,845 1,734 1,612 3,393 3,927 21 2,229 2,368 5,040 12,620 14,000 9,052 2,726 1,685 1,562 3,234 3,677 22 2,200 2,329 4,768 12,245 14,000 8,773 2,580 1,661 1,527 3,084 3,535 23 2,161 2,242 4,475 11,926 14,000 8,409 2,495 1,608 1,442 2,931 3,364 24 2,151 2,172 4,319 11,655 14,000 7,888 2,367 1,560 1,372 2,842 3,287 25 2,126 2,109 4,126 11,339 14,000 7,605 2,285 1,520 1,322 2,707 3,167 26 2,099 2,067 3,942 11,009 14,000 7,296 2,169 1,482 1,298 2,559 2,969 27 2,084 2,039 3,648 10,649 14,000 6,855 2,098 1,461 1,262 2,361 2,834 28 2,061 1,962 3,461 10,154 13,523 6,355 2,039 1,401 1,140 2,199 2,659 29 2,028 3,254 9,680 13,121 6,026 1,983 1,360 1,123 2,065 2,574 30 1,999 3,136 9,275 12,667 5,793 1,875 1,320 1,083 1,939 2,461 31 1,950 3,018 11,894 1,752 1,250 1,809 Media 2,597 3,222 7,455 12,958 13,845 10,829 4,004 2,103 3,266 5,312 6,732 Dic 10,499 8,406 6,614 5,785 5,257 4,946 4,622 4,351 4,214 4,082 3,950 3,869 3,743 3,644 3,583 3,499 3,390 3,297 3,197 3,090 3,049 3,017 2,937 2,884 2,807 2,746 2,694 2,617 2,558 2,527 2,419 4,009 L’impianto, tenuto conto della simulazione idrologica alternativa ( richiesta da Ufficio Acque ), considerate inalterate la portata massima (14,00 m3/sec) e quella minima (0,600 m3/sec ) di prelievo , avrebbe una portata media di derivazione pari a 6,364 m3/s, dunque una potenza nominale media di 309 kW; massima invariata e pari a 656 kW; le due turbine avrebbero potenza complessiva installata di 578 kW e nell’anno idrologico medio una produzione di circa 2,2 GWh di energia elettrica. Si è ritenuto per correttezza di procedimento non modificare i dati medi di concessione nei vari documenti tecnici (compresa la presente relazione ) in quanto gli stessi e in particolare l’elaborazione idrologica alternativa dovrà essere esaminata in sede di Conferenza dei Servizi. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 53 Relazione tecnica 11. TRAVERSA FLUVIALE ESISTENTE L’impianto idroelettrico in progetto valorizza energeticamente i rilasci della derivazione irrigua ed idroelettrica del Consorzio di San Gervasio dal Torrente Corsaglia al confine tra il Comune di Lesegno e quello di San Michele. La traversa della derivazione del Consorzio di San Gervasio è una struttura fissa in cemento armato con coronamento a quota media di 372.95 m s.l.m., che si estende per circa 90 m. La struttura è posta al termine di una curva planimetrica del torrente che disegna un ansa verso destra. Lo sbarramento non è perpendicolare all’asse del Torrente Corsaglia, bensì indirizza la portata verso la sponda sinistra orografica, dove è ubicata la derivazione esistente, con un angolo particolarmente marcato al punto che, a centro curva, l’opera si quasi parallela rispetto alla direzione di scorrimento della corrente. Si evidenzia come, dei 90 metri circa di sbarramento, la parte terminale in sponda sinistra, circa 20 metri, risulti poco efficace causa la ridottissima sezione disponibile a monte la quale risulta incuneata verso la derivazione irrigua. La soglia in cemento armato della traversa si estende da monte verso valle con larghezza irregolare variabile da 5.5 a 8.0 metri circa. Conseguentemente l’attuale dislivello tra la soglia e il punto più basso della struttura varia da 2,5 a 2,0metri. Al termine della struttura si percepisce un dislivello verticale di circa 1,0 / 1,5 metri. In destra orografica la traversa è ammorsata in una piccola difesa spondale in massi posta in corrispondenza di un deposito di detriti nell’interno curva. La sponda sinistra è invece caratterizzata da una formazione in arenaria sub-verticale che accompagna la portata sino alla derivazione irrigua. La stessa derivazione è attuata con un canale largo circa 60cm affiancata da uno scarico di fondo posto in adiacenza. Le due sezioni sono gestite mediante semplici paratoie piane. Figura 3: Sezione della traversa esistente Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 54 Relazione tecnica 12. INTERVENTI DI ADEGUAMENTO DELLA TRAVERSA La derivazione in progetto deriva la portata attraverso una nuova opera di captazione prevista in sponda destra orografica ovvero opposta a quella irrigua. Al fine di aumentare la sezione idraulica dell’imbocco alle prese in progetto, ottimizzare lo sfruttamento della risorsa garantendo nel contempo la derivazione del Consorzio San Gervasio, la traversa idraulica è innalzata con un sistema mobile gonfiabile. Il sistema di innalzamento mobile consente l’elevazione del pelo libero a monte dello sbarramento complessivo di 2,0 m alla quota di massima ritenuta di 374,95m s.l.m.. Per tale intervento si è optato per uno sbarramento mobile di tipo scudato ovvero dotato di un sistema di paratoie vincolate alla base Esso è composto da tre elementi essenziali: L’opera di fondazione l’opera di ritenuta e protezione l’opera di movimentazione Figura 4: Sezione della traversa nella situazione in progetto Il primo costituisce la base su cui è appoggiata l’intera struttura. Prevista in c.a., è stata pensata per essere posta in adiacenza all’esistente traversa ma da essa strutturalmente indipendente. È dotata di un taglione ammorsato nella marna sottostante e di una trave su cui poggerà lo sbarramento. La trave, posta a quota 372,95 m slm sarà corredato da un cordolo a monte di 30cm al fine di costituire la protezione alle cerniere che movimenteranno lo sbarramento. Il secondo elemento è rappresentato dalla paratoie metalliche incernierate alla base che costituiranno sia l’elemento di ritenuta dell’acqua che lo “scudo” a protezione degli organi di manovra. Le paratoie a ventola saranno movimentate da due elementi gonfiabili in gomma adagiati sulla trave di fondazione. La scelta di tale abbinamento è fatta in quanto rappresenta la miglior soluzione in termini di sicurezza, durabilità e minor rischio di inquinamento non essendo previsto l’utilizzo rilevante di oli. Alle estremità due robuste spalle in c.a., la cui sommità è prevista a quota 375,25 m slm, limitano della sezione utile dello sbarramento gonfiabile a 70 metri. La spalla destra definirà un cambio planimetrico della struttura della traversa che sarà pertanto deviata con un angolo di 21° sino alla sponda. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 55 Relazione tecnica All’estremità sinistra si è quindi affrontato il problema legato al nuovo livello ordinario dell’acqua posto a confronto con la derivazione irrigua. Figura 5: Planimetria dell’imbocco della derivazione irrigua Considerato il minimo apporto in termini di deflusso idraulico legato agli ultimi metri della traversa in sponda sinistra, si è deciso di prolungare la spalla in c.a. con una struttura sino ad incontrare l’arenaria posta a pochi metri. L’ammorsamento verrà realizzato con uno scasso nella stessa roccia ulteriormente protetto da alcuni massi opportunamente posizionati. Nella parete in c.a. così costituita sarà aperta una fessura dotata di una paratoia piana automatica. Tale paratoia permetterà di rilasciare la portata d’acqua necessaria alla derivazione irrigua in una condizione sostanzialmente invariata per il consorzio stesso che potrà continuare il proprio attingimento senza variazioni della propria opera di captazione. Figura 6: Sezione dell’imbocco della derivazione irrigua Tale portata sarà ovviamente misurata e vincolata al rispetto del diritto irriguo in essere. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 56 Relazione tecnica L’estremità destra, considerato che la porzione terminale della traversa dovrà essere oggetto di parziale demolizione, si è deciso di realizzare uno scarico di fondo utile a ridurre la sedimentazione del bacino a monte. Lo scarico, costituito da una paratoia piana, con escursione limitata, avrà la soglia a quota 370.95m slm. e sarà posto a circa 5 metri dalla scogliera esistente in sponda destra orografica. Oltre lo scarico sono previsti altri due elementi essenziali per l’adeguamento della traversa: un impianto idroelettrico volto alla valorizzazione del DMV, di cui si tratterà nei paragrafi seguenti il passaggio artificiale per l’ittiofauna Lo sbarramento viene quindi dotato di passaggio artificiale per l’ittiofauna. L’opera è planimetricamente prevista in corrispondenza dell’esistente scogliera attuale limite della traversa esistente. Figura 7: Pianta del passaggio artificiale dell’ittiofauna Figura 8: Pianta del passaggio artificiale dell’ittiofauna La rampa di risalita è prevista in c.a., con n. 33 vasche delle dimensioni di 100 x 150cm, tale soluzione permette l’agevole superamento da parte dell’ittiofauna presente nel corso d’acqua di un dislivello di oltre 5 metri. L’opera complessivamente ricopre una superficie di 4,9 x 12,6 metri. Il dettaglio geometrico delle vasche e delle gavete è esplicitato nei paragrafi successivi. Viene inoltre inserita una rampa di risalita speciale dedicata alla Lampreda, costituita da uno scatolare metallico con all’interno una fitta serie di setole. L’intervento di adeguamento della traversa è infine completato con una platea in massi cementati post a valle della stessa posti al fine di evitare eventuali fenomeni erosivi. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 57 Relazione tecnica 13. CENTRALE IDROELETTRICA PRINCIPALE 13.1. Opera di presa ed adduzione L’impianto idroelettrico principale deriva la portata in destra orografica sfruttando in nuovo carico idraulico creato dallo sbarramento gonfiabile. La presa è formata da una soglia a quota 373,25 m s.l.m., larga 6,00 m, ricavata nella parete in c.a. co costituisce la prosecuzione della traversa. La soglia è quindi posta alla medesima quota dello sfioro fisso della traversa ovvero con sbarramento abbattuto; le pareti del canale sono invece alla medesima quota delle spalle dello sbarramento, 375,25 m s.l.m. Immediatamente al di sotto della sezione di derivazione viene creato un sistema di scarico di fondo completamente rigurgitato costituito da una bocca e da un canale in c.a. che, con andamento trasversale, convoglia la portata sino allo scarico di fondo posto a lato della spalla dello sbarramento mobile. Lo scarico è attivato mediante una paratoia piana posta all’estremità del canale e sfrutta il carico idraulico che naturalmente viene a crearsi. Figura 9: Sezione dell’opera di derivazione La paratoia a settore di regolazione della derivazione è posta immediatamente a valle dell’imbocco di presa dell’impianto principale. Successivamente è prevista la realizzazione di un attraversamento in c.a. necessario per le operazioni di manutenzione ordinaria dello stesso canale, del passaggio dell’ittiofauna e dell’impianto di valorizzazione del DMV. Lo stesso solaio costituisce sostegno ad un paratronchi tubolare metallico. A valle dell’attraversamento il fondo è modellato con un arco avente funzione di sghiaiatore. Il materiale depositato è invitato verso il lato sinistro ove una paratoia piana, mediante cacciate programmate, lo allontanerà verso l’alveo. È quindi posizionata una griglia metallica inclinata di 60° accoppiata ad uno sgrigliatore automatico. Esso è dotato di un braccio meccanico che raschia la griglia dal basso verso l’alto con un pettine metallico. Il materiale sollevato, quando raggiunge la sommità della griglia cade all’interno di una tramoggia, dove un getto di acqua in pressione lo spinge verso destra fino a cadere in un cassone. La vasca in cui è contenuto il materiale raccolto dal dispositivo è dotata di fondo grigliato per Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 58 Relazione tecnica l’allontanamento dell’acqua; esso è posto sul lato destro del canale e il materiale potrà quindi essere smaltito secondo normativa. Lo sgrigliatore poggia su un solaio in c.a.; a partire da questa sezione in canale di adduzione è di tipo coperto. Pochi metri dopo il fondo subisce un marcato approfondimento sino a raggiungere la quota del distributore della turbina kaplan. La vasca che si viene a creare sarà dotata di un grigliato di sfiato. Figura 10: Pianta dell’opera di derivazione Per una maggior sicurezza in caso di piena il canale, nella sezione chiusa, potrà essere completato con una paratoia piana capace di isolare completamento l’impianto. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 59 Relazione tecnica 13.2. Edificio e meccanismi di produzione L’edificio centrale è rappresentato da una struttura in c.a. di tipo interrata. Il posizionamento dell’opera è dettato dalla volontà di porre il fabbricato ad una distanza di 10 metri dalla sponda del torrente così come previsto dal R.D. 523/04. Tale necessità ha determinato la lunghezza del precedente canale di adduzione. Il gruppi di produzione è formati da turbina Kaplan ad asse verticale. In questo spazio sono previsto solamente i quadri di gestione strettamente necessari e, anche se la quota del solaio è tale da scongiurare allagamenti, si predisporrà un sistema di pompe di sentina. Complessivamente il locale ha dimensioni interne di 6,0 x 6,5 metri ed un’altezza valutata in 5,5m. Il piano pavimento del locale è preliminarmente previsto a quota 370,30 m slm e si accederà mediante botole rimovibili in acciaio che costituiranno la copertura del locale. Il posizionamento e la manutenzione della macchina potrà essere effettuato mediante l’ausilio di un autogrù. Il sottostante diffusore sarà posto ad una quota sufficientemente profonda tale da non risentire del livello di valle. Figura 11: Sezione del vano turbine 13.3. Canale di restituzione Il canale di restituzione, completamente interrato, ha una larghezza variabile che raccorderà il diffusore alla bocca di scarico la cui larghezza è prevista di 6,5 metri. Anche il fondo scorrevole raccorderà il diffusore alla sezione di restituzione la sui soglia è fissata a quota 368,05 m slm. In tale sezione il solaio è interrotto alcuni decimetri prima della pareti così da permettere l’inserimento di gargami in acciaio utili per l’eventuale inserimento di panconi di manutenzione. Lo sviluppo complessivo a partire dall’asse della turbina, è di circa 20 metri. Allo sbocco il solaio è sormontato da un tratto di scogliera, utile a proteggere la scarpata; la stessa scogliera prosegue verso monte sino ad incontrare il canale di adduzione , e verso valle sino ad ammorsarsi nella vicina parete in marna. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 60 Relazione tecnica 14. CENTRALE DI RILASCIO E VALORIZZAZIONE ENERGETICA DEL DMV L’impianto idroelettrico di valorizzazione energetica del deflusso minimo vitale è costituito da una turbina Kaplan ad asse verticale di tipo a bulbo. La struttura è posta tra lo scarico di fondo della traversa e il passaggio artificiale dell’ittiofauna ove attualmente è presente la traversa esistente. L’opera è pertanto considerate a tutti gli effetti “entro il corpo traversa”. L’immagine sotto riportata evidenzia la posizione dell’impianto rispetto alla scogliera esistente in sponda destra (tratto verde). Figura 12 : Planimetria dell'impianto Di minori dimensioni, questo impianto secondario è stato ridotto all’essenziale al fine di limitare al massimo gli ingombri. Analogamente all’impianto principale la soglia di derivazione è posta quota 373,25 m s.l.m. e le pareti del canale sono alla medesima quota delle spalle dello sbarramento, 375,25 m s.l.m. In questo caso il canale di derivazione è largo 3,5 metri. Adottata una schema molto simile a quello precedentemente descritto, dopo la sezione di presa è prevista una paratoia a ventola, un abbassamento de fondo scorrevole e quindi una griglia metallica inclinata abbinata ad uno sgrigliatore automatico. Anche in questo caso lo sgrigliatore sarà posto su un solaio in c.a. il quale sarà realizzato con una prima parte fissa, una seconda removibile ed una terza minore grigliata. Oltre la griglia il fondo del canale si approfondisce nella vasca di carico della turbina a camera libera. La turbina è quindi completata da un diffusore che verrà inghisato in un blocco in c.a. . esso sarà sostanzialmente esterno alla struttura ma perennemente al di sotto del pelo libero dell’acqua e pertanto poco percepibile alla vista. La necessità di limitare al minimo l’ingombro dell’opera è dettata da vari aspetti tra i quali: Limitare l’impatto visivo Contenere l’opera entro lo sviluppo longitudinale della traversa Evitare che la struttura sia colpita dal flusso generatosi in caso di abbattimento dello sbarramento gonfiabile Evitare, viceversa, che la struttura costituisca ostacolo al deflusso dell’acqua La turbina di valorizzazione energetica del deflusso minimo vitale è proposta con collocazione all’interno della struttura della traversa fluviale nel pieno rispetto del Regolamento Regionale 8/R del 2003 “Disposizioni per la prima attuazione delle norme in materia di deflusso minimo vitale (Legge Regionale 29 dicembre 2000, n. 61)”. Infatti, tale norma prevede l’esenzione del rilascio del deflusso minimo vitale per le turbine collocate nel corpo della traversa, a condizione che la continuità idraulica sia assicurata da un’apposita scala di risalita della fauna ittica. L’impianto potrà essere completato con un sistema di scarico della vasca principale mediante il quale allontanare i sedimenti eventualmente accumulatisi. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 61 Relazione tecnica Figura 13: Pianta dell’impianto di valorizzazione del DMV Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 62 Relazione tecnica 15. LOCALE DI CONSEGNA ENEL Il locale di consegna ENEL, il locale quadri e gli spazi adibiti ai trasformatori sono inseriti all’interno di un unico edificio il quale è l’unico fabbricato non interrato. Funzionalmente l’edificio adibito a gestione e cessione dell’energia è divisa in quattro locali, ognuno con una funzione distinta: Il locale quadri, che contiene i quadri elettrici e i quadri MT dell’impianto idroelettrico aventi la funzione di gestire e proteggere l’allacciamento alla rete elettrica di distribuzione - Locale trasformatori, predisposto per ospitare i 2 trasformatori delle due turbine e un trasformatore ausiliario secondario, i quali possono essere rimossi in maniera indipendente in caso di manutenzione - locale di misura, contiene i misuratori dell’energia elettrica prelevata o ceduta alla rete; - locale ENEL, contiene i quadri elettrici dell’operatore elettrico che fornisce il servizio di ritiro e distribuzione dell’energia elettrica prodotta, nonché di alimentazione dei servizi ausiliari dell’impianto. Figura 14: Prospetto del locale ENEL Ciascun locale interno è accessibile direttamente dall’esterno attraverso una propria porta. L’accesso al locale ENEL è ricavato sul prospetto lato Nord – lato Torrente Corsaglia, come anche l’accesso agli altri vani. Il locale trasformatori, per migliorarne ventilazione e l’accessibilità, è dotato di un ulteriore accesso sula lato opposto. Per la medesima motivazione, entrambe le aperture, a differenza dei quelle degli altri locali, sono previste con serramenti costituiti da grigliati metallici. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 63 Relazione tecnica I locali sono previsti con le seguenti dimensioni planimetriche: locale quadri : 5,50 x 4,00metri - locale trasformatori : 5,50 x 2,55metri cui va dedotto il locale misure) - locale misure : 1,20 x 1,20metri - locale quadri : 5,50 x 3,50metri Figura 15: Pianta del locale ENEL e locale quadri e trasformatori Le dimensioni e nonché i serramenti, i grigliati e, più in generale, i caratteri progettuali dei due locali devono sottostare ai capitolati ENEL. Si prevedono pertanto: - cavedi al piano pavimento, - accessi con porte in vetroresina - ventilazione con grigliati in vetroresina e illuminazione mediante pareti in vetrocemento L’inserimento di un solaio interposto tra il locale quadri e la copertura permette di ovviare a tali prescrizioni permettendo di realizzare un tetto in legno anche in corrispondenza dei locali ENEL migliorando l’inserimento paesaggistico dell’opera. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 64 Relazione tecnica 16. GESTIONE DELLA PORTATA 16.1. Dispositivi di modulazione della portata La distribuzione delle portate presso l’opera di presa è regolata da dispositivi idraulici di modulazione classificabili in: dispositivi di modulazione fissi; dispositivi di modulazione mobili. Un’altra possibile classificazione dei dispositivi di modulazione delle portate in base alla propria funzione è: dispositivi di rilascio; dispositivi per la garanzia del prelievo irriguo; dispositivi del prelievo idroelettrico; dispositivi di sbarramento. Nella pagina che segue sono elencati i dispositivi di modulazione della portata con la classificazione, la descrizione e la regola operativa di funzionamento. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 65 Relazione tecnica Dispositivo Descrizione Regola operativa Fisso Il passaggio artificiale per l’ittiofauna è del tipo a bacini successivi collegati idraulicamente attraverso fenditure verticali a tutta altezza. L’alimentazione avviene direttamente dal bacino a monte della traversa fluviale e corrisponde 3 alla portata di 0,128 m /s. Il corretto rilascio della portata di competenza del passaggio artificiale per l’ittiofauna avviene con il carico idraulico di progetto a monte dello sbarramento pari a 374,95 m s.l.m.. Paratoia di presa Mobile La paratoia a ventola della turbina di rilascio del deflusso minimo vitale è posta all’ingresso del canale di adduzione ed è larga 3,50 m come il canale stesso. L’innalzamento massimo della paratoia è pari alla sommità delle pareti del canale 375,25 m s.l.m., mentre, quando abbattuta, è posta alla medesima quota della soglia di presa, 273,25 m s.l.m.. La paratoia di presa permette la disattivazione della turbina per la valorizzazione energetica del deflusso minimo vitale. La paratoia ha funzionamento esclusivamente ON ÷ OFF, cioè è solamente previsto che sia completamente chiusa o totalmente aperta. Turbina idraulica Mobile La turbina di rilascio del deflusso minimo vitale è di tipo Kaplan biregolante ad asse verticale, con distributore radiale in camera libera e girante a quattro pale. Essa è accoppiata in presa diretta ad un generatore sincrono a magneti permanenti custodito in un bulbo stagno immerso nella camera libera di alimentazione della macchina idraulica. La turbina opera con portate comprese tra 0,600 m3/s e 4,000 m3/s. La turbina è regolata al fine di mantenere il carico idraulico di progetto a monte dello sbarramento pari a 374,95 m s.l.m.. Essa è esercita con priorità rispetto a quella dell’impianto principale ed è previsto un rilascio minimo di 1,143 m3/s. I meccanismi di regolazione della macchina idraulica costituiscono anche il dispositivo di limitazione della portata massima di competenza della turbina di valorizzazione energetica del deflusso minimo vitale. Paratoia irrigua Mobile La paratoia per l’alimentazione del canale irriguo San Gervasio è prevista in sinistra orografica in corrispondenza della spalla dello sbarramento mobile. La paratoia, larga 2,00 m ha soglia a quota 372,30 m s.l.m. ed elevazione massima alla medesima quota dello sbarramento fisso in porgetto, 373,25 m s.l.m.. La paratoia alimenta l’imbocco del canale irriguo, dove sono presenti la paratoia di presa e quella di scarico. La paratoia alimenta l’imbocco del canale irriguo e mantiene un carico idraulico pari alla soglia di sfioro esistente di 372,95 m s.l.m. (la misura è effettuata con un idrometro a bacchetta). Questa condizione replica esattamente la situazione esistente, pertanto l’esercizio della derivazione irrigua è svolto con la medesima regola operativa attuale. L’apertura della paratoia è subordinato al rilascio del deflusso minimo vitale di base di 0,640 m3/s attraverso il passaggio artificiale per l’ittiofauna e la turbina nel carpo traversa. Paratoia di presa Mobile La paratoia a ventola della turbina dell’impianto principale è posta all’ingresso del canale di adduzione ed è larga 6,00 m come il canale stesso. L’innalzamento massimo della paratoia è pari alla sommità delle pareti del canale 375,25 m s.l.m., mentre, quando abbattuta, è posta alla medesima quota della soglia di presa, 273,25 m s.l.m.. La paratoia di presa permette la disattivazione della turbina per la valorizzazione energetica del deflusso minimo vitale. La paratoia ha funzionamento esclusivamente ON ÷ OFF, cioè è solamente previsto che sia completamente chiusa o totalmente aperta. Turbine idrauliche Mobile La turbina dell’impianto principale è di tipo Kaplan biregolante ad asse verticale, con distributore radiale in camera forzata e girante a quattro pale. Essa è accoppiata ad un generatore sincrono a magneti indotti custodito nella sala macchina al di sopra della turbina idraulica. La turbina opera con portate comprese tra 0,600 m3/s e 4,000 m3/s. La turbina è regolata al fine di mantenere il carico idraulico di progetto a monte dello sbarramento pari a 374,95 m s.l.m.. Essa è esercita in subordine rispetto a quella dell’impianto di valorizzazione energetica del deflusso minimo vitale. In particolare è previsto che la portata di competenza sia ripartita in modo proporzionale a quella massima d’esercizio. Questa condizione assicura il corretto rilascio del deflusso minimo vitale, comprensivo sia della componente di base sia di quella modulata. I meccanismi di regolazione della macchina idraulica costituiscono anche il dispositivo di limitazione della portata massima di competenza della turbina dell’impianto principale. Sbarramento mobile Mobile Lo sbarramento è composto da una soglia fissa in cemento armato alla quota di 373,25 m s.l.m. ed un sovralzo mobile di 1,70 m di altezza massima. Il dispositivo innalza il coronamento della traversa fino alla soglia di 374,95 m s.l.m., pari alla quota idrometrica di progetto da mantenere a monte dello sbarramento fluviale. Lo sbarramento mobile è formato da una paratoia a ventola azionata da un dispositivo gonfiabile costituito da un telo elastomerico fibrorinforzato ancorato alla soglia fissa in cemento armato. Lo sbarramento mobile è ordinariamente mantenuto con la sommità alla quota di progetto di 374,95 m s.l.m.. In caso di eccessiva disponibilità idrica nel torrente, lo sbarramento mobile è progressivamente abbassato per mantenere il carico idraulico di progetto di 374,95 m s.l.m. che garantisce l’ottimale alimentazione dei dispositivi di rilascio del deflusso minimo vitale e di risalita per l’ittiofauna e la dovuta sicurezza idraulica del torrente. Dispositivi di sbarramento Dispositivi del prelievo idroelettrico Dispositivi per la garanzia del prelievo irriguo Dispositivi di rilascio Passaggio artificiale l’ittiofauna Tipo per Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 66 Relazione tecnica 16.2. Dispositivo di limitazione della portata derivata La limitazione del prelievo, sia nell’impianto di valorizzazione energetica del deflusso minimo vitale sia in quello principale, è operata dai meccanismi di regolazione delle turbine idrauliche, che sono tarati per impedire il passaggio di una portata maggiore di quella massima di concessione. I dispositivi sono regolati in continuo in funzione della misura delle portate derivate dalle singole turbine idrauliche. 16.3. Dispositivi di misura della portata L’impianto è dotato di dispositivi automatici di misura continua della distribuzione delle portate presso l’opera di captazione. In particolare si rilevano le seguenti portate: rilasciata; derivata. La somma delle due misure corrisponde alla portata disponibile nel torrente a monte dell’opera di presa, al netto della derivazione irrigua del Consorzio San Gervasio. La portata rilasciata nel tratto sotteso è misurata con un sensore idrometrico ad ultrasuoni posto a monte della traversa fluviale in progetto. Esso misura l’altezza piezometrica della vena idraulica che alimenta il passaggio artificiale per l’ittiofauna e di quella che stramazza sulla soglia dello sbarramento. Un inclinometro installato sulla paratoia a ventola dello sbarramento mobile permette di determinare l’altezza della soglia dello stesso e quindi la geometria della traversa. La portata rilasciata attraverso la turbina di valorizzazione energetica del deflusso minimo vitale è misurata per via indiretta in funzione della potenza generata dal gruppo turbina generatore. Due idrometri ad immersione installati nella vasca di carico e presso la restituzione misurano il salto idraulico tra i peli morti a monte ed a valle della turbina. Anche la portata derivata dall’impianto principale è misurata per via indiretta in funzione della potenza generata dal gruppo turbina generatore. Anche in questo caso, due idrometri ad immersione installati nella vasca di carico e presso la restituzione misurano il salto idraulico tra i peli morti a monte ed a valle della turbina. La misura della portata valorizzata energeticamente dalle due turbine è misurata per via indiretta poiché l’impianto è così compatto che non è possibile individuare una sezione adatta a sistemi di misura basati sul livello idrometrico o sul metodo area ÷ velocità. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 67 Relazione tecnica 16.4. Dispositivi di controllo visivo e di misura diretta delle portate derivata e rilasciata La portata rilasciata attraverso il passaggio artificiale per l’ittiofauna è misurabile attraverso uno stramazzo in parete sottile realizzato tra l'undicesima e la quattordicesima vasca. Una chiusa metallica rimovibile permette di attivare lo stramazzo e la medesima consente di disattivare il passaggio tra l'undicesima vasca e quella successiva. Per mantenere in posizione la chiusa metallica sono previsti gargami sia in corrispondenza della fenditura verticale sia in corrispondenza dello stramazzo di verifica. Per facilitare le operazioni di verifica è installato un grigliato sulla decima vasca a creare una piattaforma di lavoro. Nella vasca di alimentazione dello stramazzo, che funge da bacino di calma, è posta una targa in acciaio inox che indica il livello corrispondente alla portata di 0,128 m3/s. Una seconda targa in acciaio inox è posta sul petto dello sbarramento a destra dell’imbocco di monte del passaggio artificiale per l’ittiofauna ed indica il livello idrometrico di progetto pari a 374,95 m s.l.m., 3 che garantisce l’alimentazione del dispositivo di risalita con la portata di competenza di 0,128 m /s. I canali di adduzione delle turbine idrauliche non presentano sezioni regolari in cui poter misurare la portata valorizzata dalla rispettiva macchina idraulica. Inoltre gli scarichi sboccano direttamente nella platea a valle dello sbarramento, senza canali di restituzione. Di conseguenza non è possibile individuare delle sezioni che permettano la verifica della portata deriva da parte degli Enti preposti. Per semplificare l’operazione di verifica sono comunque installate aste idrometriche nei canali di carico e presso le bocche di scarico per misurare il salto idraulico valorizzato dalle singole turbine. Inoltre il display per l’evidenziazione delle portate riporta anche i valori di potenza misurata istantaneamente ai morsetti dei due generatori. In questo modo la verifica della portata derivata è condotta per via indiretta sulla base della potenza generata e del salto idraulico. 16.5. Dispositivo di evidenziazione delle portate Presso l’edificio quadri di gestione è installato un display, visibile dall’esterno, che evidenzia la misura delle seguenti portate: disponibile a monte dello sbarramento (al netto della derivazione irrigua); derivata dall’impianto principale; rilasciata attraverso la turbina di valorizzazione energetica del DMV; rilasciata attraverso altri dispositivi. Il display indica anche il volume d’acqua turbinato (complessivo per le due turbine) dall’inizio dell’anno solare in corso. Inoltre il display evidenzia le misure ai morsetti dei generatori dei due gruppi di produzione: turbina di rilascio e valorizzazione energetica del deflusso minimo vitale; turbina dell’impianto principale. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 68 Relazione tecnica 16.6. Ripartizione della portata Come specificato al precedente paragrafo 16.1. “Dispositivi di modulazione della portata”, il rilascio del deflusso minimo vitale avviene attraverso il passaggio artificiale per l’ittiofauna e la turbina nel corpo della traversa. La corretta alimentazione del passaggio artificiale per l’ittiofauna (0,128 m3/s) è assicurata dal mantenimento del carico idrometrico alla quota di progetto di 374,95 m s.l.m. a monte dello sbarramento. Il passaggio artificiale per l’ittiofauna è verificato nell’apposito paragrafo 16.9. “Passaggio artificiale per l’ittiofauna”. Il carico idraulico a monte della traversa è regolato sia dallo sbarramento mobile sia dalle turbine idrauliche. I dispositivi di rilascio del deflusso minimo vitale sono rappresentati da: passaggio artificiale per l’ittiofauna; turbina nel corpo traversa. 3 Il primo dispositivo rilascia una portata costante di 0,128 m /s, che ottimizza anche la funzione di passaggio per l’ittiofauna. La portata complementare, che completa il deflusso minimo vitale è rilasciata attraverso la turbina di valorizzazione del DMV. La successiva Tabella 11 riporta la distribuzione della portata in funzione di quella disponibile nel fiume Tanaro. I simboli utilizzati hanno i seguenti significati: portata disponibile; Qdisp Qril portata rilasciata a valle della traversa; = 0,640 m3/s deflusso minimo vitale di base; DMVbase Qril PAI portata rilasciata nel passaggio per i pesci; = 0,128 m3/s portata del passaggio per i pesci; QPAI portata rilasciata con la turbina del DMV; Qril D Qmin D = 0,600 m3/s portata minima della turbina del DMV; 3 = 4,000 m /s portata massima della turbina del DMV; Qmax D portata derivata; Qder Qmin P = 1,500 m3/s portata minima dell’impianto principale; = 10,000 m3/s portata massima dell’impianto principale. Qmax P Nella Tabella 11 non sono considerate le portate minori del deflusso minimo vitale di base, poiché tale condizione si verifica raramente. Comunque, anche in questa situazione è data priorità di funzionamento idraulico al passaggio artificiale per l’ittiofauna. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 69 Relazione tecnica Tabella 11: Distribuzione delle portate Qdisp Qdisp ≤ QPAI Qdisp ≤ 0,128 m3/s QPAI < Qdisp < DMVbase 0,128 m3/s < Qdisp < 0,640 m3/s DMVbase ≤ Qdisp < QPAI + Qmin D 0,640 m3/s ≤ Qdisp < 0,728 m3/s QPAI + Qmin D ≤ Qdisp ≤ QPAI + Qmax D 0,728 m3/s ≤ Qdisp ≤ 4,128 m3/s QPAI + Qmax D < Qdisp ≤ QPAI + Qmax D + Qmax P 4,128 m3/s < Qdisp ≤ 14,128 m3/s Qdisp > QPAI + Qmax D + Qmax P Qdisp > 14,128 m3/s Qril Qril = Qdisp 0,000 m3/s ≤ Qril ≤ 0,128 m3/s Qril PAI = Qdisp 0,000 m3/s ≤ Qril PAI ≤ 0,128 m3/s Qril D = 0 Qril D = 0,000 m3/s Qril = Qdisp 0,128 m3/s < Qril < 0,640 m3/s Qril PAI = QPAI Qril PAI = 0,128 m3/s Qril D = 0 Qril D = 0,000 m3/s Qril = Qdisp 0,640 m3/s ≤ Qril < 0,728 m3/s Qril PAI = QPAI Qril PAI = 0,128 m3/s Qril D = 0 Qril D = 0,000 m3/s Qder Qder = 0 Qder = 0,000 m3/s Regola operativa Tutta la portata è rilasciata attraverso il passaggio artificiale per l’ittiofauna. Lo sbarramento mobile è completamente alzato (374,95 m s.l.m.). La turbina del DMV è disattivata attraverso la paratoia a ventola. La paratoia irrigua è chiusa. La turbina principale è disattivata attraverso la paratoia a ventola. Qder = 0 Qder = 0,000 m3/s Tutta la portata è rilasciata attraverso il passaggio artificiale per l’ittiofauna. Lo sbarramento mobile è regolato per rilasciare la portata disponibile in esubero e mantenere il carico idraulico di progetto di 374,95 m s.l.m.. La turbina del DMV è disattivata attraverso la paratoia a ventola. La paratoia irrigua è chiusa. La turbina principale è disattivata attraverso la paratoia a ventola. Tutta la portata è rilasciata attraverso il passaggio artificiale per l’ittiofauna. Lo sbarramento mobile è regolato per rilasciare la portata disponibile in esubero e mantenere il carico idraulico di progetto di 374,95 m s.l.m.. La turbina del DMV è disattivata attraverso la paratoia a ventola. La paratoia irrigua è regolata per mantenere nell’imbocco del canale irriguo il livello idraulico di progetto (372,95 m s.l.m.). La turbina principale è disattivata attraverso la paratoia a ventola. Tutta la portata è rilasciata attraverso il passaggio artificiale per l’ittiofauna. Lo sbarramento mobile è completamente alzato (374,95 m s.l.m.). La turbina del DMV è regolata per mantenere il carico idraulico di progetto di 374,95 m s.l.m.. La paratoia irrigua è regolata per mantenere nell’imbocco del canale irriguo il livello idraulico di progetto (372,95 m s.l.m.). La turbina principale è disattivata attraverso la paratoia a ventola. Tutta la portata è rilasciata attraverso il passaggio artificiale per l’ittiofauna. Lo sbarramento mobile è completamente alzato (374,95 m s.l.m.). La turbina del DMV e quella principale sono regolate per mantenere il carico idraulico di progetto di 374,95 m s.l.m.. La ripartizione della portata tra le turbine è proporzionale alla portata massima d’esercizio delle stesse, in questo modo è assicurato un rilascio modulato del deflusso minimo vitale con rapporto di modulazione minimo del 18%. La paratoia irrigua è regolata per mantenere nell’imbocco del canale irriguo il livello idraulico di progetto (372,95 m s.l.m.). Tutta la portata è rilasciata attraverso il passaggio artificiale per l’ittiofauna. Lo sbarramento mobile è regolato per rilasciare la portata disponibile in esubero e mantenere il carico idraulico di progetto di 374,95 m s.l.m.. La turbina del DMV e quella principale sono regolate per mantenere il carico idraulico di progetto di 374,95 m s.l.m.. La ripartizione della portata tra le turbine è proporzionale alla portata massima d’esercizio delle stesse, in questo modo è assicurato un rilascio modulato del deflusso minimo vitale con rapporto di modulazione minimo del 18%. La paratoia irrigua è regolata per mantenere nell’imbocco del canale irriguo il livello idraulico di progetto (372,95 m s.l.m.). Qder = 0 Qder = 0,000 m3/s Qril = Qdisp 0,728 m3/s ≤ Qril ≤ 4,128 m3/s Qril PAI = QPAI Qril PAI = 0,128 m3/s Qmin D ≤ Qril D ≤ Qmax D 0,600 m3/s ≤ Qril D ≤ 4,000 m3/s 1,271 m3/s < Qril ≤ QPAI + Qmax D 1,271 m3/s < Qril ≤ 4,128 m3/s Qril PAI = QPAI Qril PAI = 0,128 m3/s Qmin D ≤ Qril D ≤ Qmax D 1,143 m3/s ≤ Qril D ≤ 4,000 m3/s Qder = 0 Qder = 0,000 m3/s Qril > QPAI + Qmax D Qril > 4,128 m3/s Qril PAI = QPAI Qril PAI = 0,128 m3/s Qril D = Qmax D Qril D = 4,000 m3/s Qder = Qmax P Qder = 10,000 m3/s 2,857 m3/s < Qder ≤ Qmax P 2,857 m3/s < Qder ≤ 10,000 m3/s Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 70 Relazione tecnica 16.7. Gestione della derivazione irrigua del Consorzio San Gervasio Il progetto prevede l’installazione di una paratoia per l’alimentazione del canale irriguo all’interno della spalla sinistra della traversa mobile, appena a monte della paratoia a ventola di sbarramento. La paratoia alimenta l’imbocco del canale irriguo, a monte delle relative paratoie di presa e di scarico di fondo. Questo tratto di canale di imbocco coincide con la porzione terminale della traversa fluviale esistente. La gestione della paratoia di alimentazione del canale irriguo è attuata nel rispetto dei seguenti parametri: rilascio del deflusso minimo vitale di base di 0,640 m3/s attraverso il passaggio artificiale per l’ittiofauna ed altri dispositivi; mantenimento dell’altezza idrometrica di 372,95 m s.l.m. a monte della paratoia esistente della presa irrigua; stessa quota della soglia dello sfioratore. In questo modo la derivazione irrigua è esercitata con condizioni idrometriche identiche a quelle attuali. Di conseguenza non è necessario adeguare alcuna struttura del Consorzio Irriguo San Gervasio. Anche i dispositivi di limitazione e regolazione della portata del canale irriguo mantengono la loro funzionalità attuale, senza necessità di adeguamento. 16.8. Distribuzione della portata derivabile tra le turbine idrauliche La distribuzione della portata derivabile tra le turbine idrauliche è attuata nel rispetto dei seguenti principi: portata derivabile minore di 4,000 m3/s con portate derivabili complessive minori di quella massima d’esercizio dell’impianto di rilascio e valorizzazione energetica del deflusso minimo vitale, la turbina principale è disattivata e tutta la portata è processata attraverso la macchina idraulica collocata nel corpo della traversa fluviale; - portata derivabile compresa tra 4,000 m3/s e 14,000 m3/s con portate derivabili complessive maggiori di quella massima d’esercizio dell’impianto di rilascio e valorizzazione energetica del deflusso minimo vitale, sono attivate entrambe le macchine idrauliche e la ripartizione della portata avviene in proporzione a quella massima d’esercizio della singola turbina. Operando come indicato dalle curve di durata delle portate derivabili nell’anno idrologico medio indicate nella Tabella 12, si ottengono i deflussi a disposizione della turbina principale e di quella di valorizzazione del deflusso minimo vitale, rispettivamente riportate nella Tabella 13 e nella Tabella 14. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 71 Relazione tecnica 3 Tabella 12: Curve di durata della portata derivabile (m /s) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Media Gen Feb 5,190 4,852 4,432 4,232 4,131 4,032 3,915 3,827 3,741 3,704 3,549 3,315 3,248 3,185 3,140 3,089 3,022 2,946 2,878 2,858 2,751 2,677 2,626 2,600 2,565 2,537 2,520 2,486 2,464 2,410 2,326 3,266 6,510 5,976 5,670 5,207 4,703 4,488 4,385 4,292 4,111 3,984 3,883 3,758 3,646 3,567 3,371 3,289 3,196 3,168 3,136 3,076 3,011 2,916 2,884 2,832 2,763 2,742 2,695 2,639 Mar 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,821 12,207 11,281 10,176 9,705 9,431 9,143 8,983 8,641 8,372 7,711 7,328 7,026 6,688 6,508 6,299 6,142 5,984 5,937 5,842 5,726 5,558 3,782 9,823 Apr 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,884 13,386 12,876 12,697 12,290 11,985 11,660 11,427 11,218 11,061 10,669 9,991 9,767 Mag 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,976 13,425 13,115 12,955 12,800 12,617 12,477 12,144 11,958 11,679 11,498 10,303 9,407 9,061 8,673 8,016 13,030 12,713 Giu 14,000 14,000 12,917 11,907 11,293 10,740 10,509 9,997 9,095 8,501 8,307 8,111 7,947 7,784 7,485 7,364 7,286 6,979 6,378 5,926 5,512 5,118 4,718 4,569 4,330 4,208 4,057 3,936 3,801 3,654 Lug 4,274 3,943 3,768 3,486 3,364 3,191 3,088 2,735 2,630 2,567 2,533 2,431 2,326 2,259 2,182 2,128 2,076 2,003 1,934 1,869 1,770 1,745 1,682 1,626 1,499 1,465 1,413 1,374 1,327 1,290 1,191 7,681 2,296 Ago Set 3,452 2,522 1,745 1,648 1,585 1,536 1,501 1,445 1,361 1,331 1,288 1,252 1,213 1,185 1,150 1,120 1,103 1,094 1,060 1,043 1,010 0,972 0,948 0,924 0,901 0,890 0,864 0,821 0,741 0,688 0,623 1,259 8,126 6,595 4,270 2,679 2,044 1,897 1,798 1,714 1,579 1,452 1,424 1,336 1,267 1,217 1,159 0,978 0,907 0,847 0,827 0,795 0,739 0,705 0,685 0,653 0,649 0,640 0,625 0,000 0,000 0,000 Ott 14,000 5,756 4,100 3,119 2,867 2,712 2,507 2,083 2,023 1,913 1,590 1,521 1,398 1,381 1,323 1,276 1,263 1,259 1,237 1,207 1,190 1,114 1,067 1,037 1,004 0,998 0,976 0,948 0,873 0,828 0,785 1,587 2,108 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Nov Dic 14,000 14,000 14,000 14,000 14,000 14,000 14,000 13,884 11,582 10,221 8,945 8,256 7,873 7,276 6,886 6,337 6,075 5,931 5,720 5,263 4,951 4,619 4,430 4,212 4,083 3,941 3,806 3,018 2,908 2,791 13,617 9,739 7,894 7,289 6,475 6,163 5,554 5,289 5,145 4,962 4,714 4,613 4,538 4,318 4,167 4,036 3,898 3,584 3,470 3,300 3,280 3,229 3,132 3,058 2,916 2,847 2,819 2,731 2,641 2,568 2,520 8,034 4,661 72 Relazione tecnica 3 Tabella 13: Curve di durata della portata della turbina principale (m /s) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Media Gen Feb 3,707 3,466 3,166 3,023 2,950 2,880 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,619 4,650 4,268 4,050 3,719 3,360 3,206 3,132 3,066 2,937 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 Mar 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 9,872 8,719 8,058 7,269 6,932 6,737 6,531 6,417 6,172 5,980 5,508 5,234 5,019 4,777 4,648 4,499 4,387 4,275 4,241 4,173 4,090 3,970 1,157 7,016 Apr 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 9,917 9,562 9,197 9,070 8,779 8,561 8,328 8,162 8,013 7,901 7,621 7,136 6,977 Mag 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 9,983 9,589 9,368 9,254 9,143 9,012 8,912 8,674 8,542 8,342 8,213 7,359 6,719 6,472 6,195 5,726 9,307 9,081 Giu 10,000 10,000 9,226 8,505 8,067 7,671 7,507 7,141 6,496 6,072 5,934 5,794 5,677 5,560 5,346 5,260 5,205 4,985 4,556 4,233 3,937 3,656 3,370 3,264 3,093 3,005 2,898 0,000 0,000 0,000 Lug 3,053 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 5,215 0,098 Ago Set 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 5,804 4,711 3,050 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 Ott 10,000 4,112 2,929 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,452 0,550 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Nov Dic 10,000 10,000 10,000 10,000 10,000 10,000 10,000 9,917 8,273 7,301 6,389 5,897 5,623 5,197 4,919 4,527 4,339 4,236 4,085 3,759 3,536 3,300 3,164 3,009 2,917 0,000 0,000 0,000 0,000 0,000 9,726 6,957 5,639 5,206 4,625 4,402 3,967 3,778 3,675 3,544 3,367 3,295 3,241 3,084 2,977 2,883 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 5,346 2,270 73 Relazione tecnica 3 Tabella 14: Curve di durata della portata della turbina nel corpo traversa (m /s) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Media Gen Feb 1,483 1,386 1,266 1,209 1,180 1,152 3,915 3,827 3,741 3,704 3,549 3,315 3,248 3,185 3,140 3,089 3,022 2,946 2,878 2,858 2,751 2,677 2,626 2,600 2,565 2,537 2,520 2,486 2,464 2,410 2,326 2,647 1,860 1,707 1,620 1,488 1,344 1,282 1,253 1,226 1,175 3,984 3,883 3,758 3,646 3,567 3,371 3,289 3,196 3,168 3,136 3,076 3,011 2,916 2,884 2,832 2,763 2,742 2,695 2,639 Mar 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 3,949 3,488 3,223 2,907 2,773 2,695 2,612 2,567 2,469 2,392 2,203 2,094 2,008 1,911 1,859 1,800 1,755 1,710 1,696 1,669 1,636 1,588 2,625 2,807 Apr 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 3,967 3,825 3,679 3,628 3,512 3,424 3,331 3,265 3,205 3,160 3,048 2,855 2,791 Mag 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 3,993 3,836 3,747 3,702 3,657 3,605 3,565 3,470 3,417 3,337 3,285 2,944 2,688 2,589 2,478 2,290 3,723 3,632 Giu 4,000 4,000 3,690 3,402 3,227 3,069 3,003 2,856 2,599 2,429 2,373 2,317 2,271 2,224 2,138 2,104 2,082 1,994 1,822 1,693 1,575 1,462 1,348 1,306 1,237 1,202 1,159 3,936 3,801 3,654 Lug 1,221 3,943 3,768 3,486 3,364 3,191 3,088 2,735 2,630 2,567 2,533 2,431 2,326 2,259 2,182 2,128 2,076 2,003 1,934 1,869 1,770 1,745 1,682 1,626 1,499 1,465 1,413 1,374 1,327 1,290 1,191 2,466 2,197 Ago Set 3,452 2,522 1,745 1,648 1,585 1,536 1,501 1,445 1,361 1,331 1,288 1,252 1,213 1,185 1,150 1,120 1,103 1,094 1,060 1,043 1,010 0,972 0,948 0,924 0,901 0,890 0,864 0,821 0,741 0,688 0,623 1,259 2,322 1,884 1,220 2,679 2,044 1,897 1,798 1,714 1,579 1,452 1,424 1,336 1,267 1,217 1,159 0,978 0,907 0,847 0,827 0,795 0,739 0,705 0,685 0,653 0,649 0,640 0,625 0,000 0,000 0,000 Ott 4,000 1,645 1,172 3,119 2,867 2,712 2,507 2,083 2,023 1,913 1,590 1,521 1,398 1,381 1,323 1,276 1,263 1,259 1,237 1,207 1,190 1,114 1,067 1,037 1,004 0,998 0,976 0,948 0,873 0,828 0,785 1,135 1,559 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Nov Dic 4,000 4,000 4,000 4,000 4,000 4,000 4,000 3,967 3,309 2,920 2,556 2,359 2,249 2,079 1,968 1,811 1,736 1,694 1,634 1,504 1,415 1,320 1,266 1,204 1,167 3,941 3,806 3,018 2,908 2,791 3,890 2,783 2,255 2,083 1,850 1,761 1,587 1,511 1,470 1,418 1,347 1,318 1,296 1,234 1,191 1,153 3,898 3,584 3,470 3,300 3,280 3,229 3,132 3,058 2,916 2,847 2,819 2,731 2,641 2,568 2,520 2,687 2,392 74 Relazione tecnica 16.9. Passaggio artificiale per l’ittiofauna Il passaggio artificiale per l’ittiofauna è del tipo “a bacini successivi”. Esso è costituito da una serie di vasche successive collegate da fenditure verticali. Tali fenditure sono accostate ad una parete del passaggio in modo alternato in modo che non si formi una vena principale di deflusso. Esse sono alte 0,85 m come le vasche e presentano larghezza di 0,05 m per i primi 0,30 m dal fondo e 0,20 m nella porzione più elevata. Ciascuna vasca ha pianta rettangolare larga 1,00 m e lunga 1,50 m. Il dislivello tra due bacini successivi è costante e pari a 0,15 m. Il passaggio artificiale per l’ittiofauna è alimentato da una portata pari a 0,128 m3/s, pari al 20% del deflusso minimo vitale di base. L’attrattività del passaggio verso valle è favorita dalla vicina turbina di rilascio e valorizzazione energetica del deflusso minimo vitale ubicata nel corpo della traversa. Sulla parete di una vasca è ricavato uno stramazzo largo 0,50 m e profondo 0,27 m per la verifica della portata da parte degli Enti competenti. Lo stramazzo è normalmente tappato da una chiusa metallica, che quando rimossa serve a disabilitare la fenditura verticale in modo che tutta la portata defluisca attraverso il dispositivo di verifica. La chiusa metallica è tenuta ferma da appositi gargami, previsti sia presso lo stramazzo di verifica sia presso la fenditura verticale. 16.9.1. Verifica delle fenditure L’espressione per la verifica dei passaggi idraulici rigurgitati è: Q = µ ⋅ L2 ⋅ h3 ⋅ 2 g ⋅ h1 + µ ⋅ L1 ⋅ h2 ⋅ 2 g ⋅ h1 + 2 ⋅ µ ⋅ L1 ⋅ h1 ⋅ 2 g ⋅ h1 3 con: - Q µ = 0,65 L1 = 0,20 m L2 = 0,05 m g = 9,81 m/s2 h1 = 0,15 m h2 = 0,40 m h3 = 0,30 m portata; coefficiente di portata (Schoklitsch); larghezza della parte alta; larghezza della parte profonda; accelerazione di gravità; altezza della vena libera; altezza della vena rigurgitata alta. altezza della vena rigurgitata profonda. Sostituendo i dati nella formula si ottiene: Q= = 0,65 ⋅ 0,05 ⋅ 0,30 ⋅ 2 g ⋅ 0,15 + + 0,65 ⋅ 0,20 ⋅ 0,40 ⋅ 2 g ⋅ 0,15 + 2 + ⋅ 0,65 ⋅ 0,20 ⋅ 0,15 ⋅ 2 g ⋅ 0,15 = 3 = 0,128 m3 s La verifica è soddisfatta. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 75 Relazione tecnica 16.9.2. Verifica della velocità nei passaggi Affinché l’ittiofauna affronti in modo agevole il passaggio preposto alla risalita, la velocità massima non deve superare 1,5 m/s. La verifica è condotta nei passaggi costituiti dalle fenditure verticali, in cui la velocità raggiunge i valori massimi. La velocità della corrente attraverso un passaggio idraulico è riconducibile a: U= Q Ω con: U 3 Q = 0,128 m /s - velocità della corrente; larghezza dello stramazzo; superficie idraulica. Ω Riconducendosi alla geometria delle fenditure indicata in precedenza, la superficie idraulica è pari a: Ω = L1 ⋅ h1 + L1 ⋅ h2 + L2 ⋅ h3 = = 0,20 ⋅ 0,15 + 0, 20 ⋅ 0,40 + 0,05 ⋅ 0,30 = 0,125 m 2 Sostituendo i relativi valori nella formula si ottiene: U= 0,128 = 1,03 m s 0,125 La velocità massima nei passaggi idraulici rispetta le prescrizioni. 16.9.3. Verifica della dissipazione di energia In ciascuna vasca deve essere dissipata una quantità di energia minore od uguale a 140 W/m3. La potenza dissipata nelle vasche del passaggio artificiale per l’ittiofauna è calcolata con l’espressione: P = γ ⋅ Q ⋅ ∆h dove - P γ = 9810 N/m 3 Q = 0,128 m3/s ∆h = 0,15 m potenza; peso specifico dell’acqua; portata; salto idraulico. Sostituendo i valori si ottiene quindi: P = 9810 ⋅ 0,128 ⋅ 0,15 = 189 W Ciascuna vasca è larga 1,00 m, lunga 1,50 m e profonda 0,85 m. Pertanto il volume delle vasche è pari a: V = 1,00 ⋅1,50 ⋅ 0,85 = 1,275 m 3 Ne consegue che la potenza specifica dissipata in ciascuna vasca è: P 189 = = 148 W m3 V 1,275 Anche la dissipazione energetica all’interno delle vasche è verificata. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 76 Relazione tecnica 16.9.4. Verifica dello stramazzo Bazin per il controllo della portata Nell’ipotesi che la luce di questo tipo di stramazzo sia decomponibile nella somma di infinite luci a battente in parete sottile di altezza infinitesima dz, sotto un carico z, con coefficiente di portata µ, si ottiene: dQ = µ ⋅ L ⋅ 2 g ⋅ z ⋅ dz il cui integrale fra 0 ed h fornisce la portata: Q= 2 µ ⋅ L ⋅ h ⋅ 2g ⋅ h 3 I simboli hanno il seguente significato: Q portata; µ = 0,62 coefficiente di deflusso. L = 0,50 m larghezza della soglia; 2 g = 9,81 m/s accelerazione di gravità; h = 0,27 m carico idraulico. Sostituendo i valori nell’equazione si ottiene: Q= 2 ⋅ 0,62 ⋅ 0,50 ⋅ 0,27 ⋅ 2 g ⋅ 0,27 = 0,128 m3 s 3 Pertanto lo stramazzo è verificato. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 77 Relazione tecnica 17. SALTO IDRAULICO 17.1. Quota idrometrica a monte A monte della traversa il livello idrometrico è mantenuto costantemente alla quota di progetto di 374,95 m s.l.m.. Di seguito si procede alla definizione delle perdite di carico nei canali di adduzione dell'impianto, in modo indipendente per ciascuna turbina idraulica installata. 17.1.1. Metodo di calcolo In entrambi i canali di adduzione dell'impianto idroelettrico in progetto si riscontrano due perdite di carico concentrate: soglia di presa; griglia di pulizia. Le perdite di carico distribuite sono invece trascurabili rispetto a quelle concentrate e pertanto non sono quantificate. Soglia di presa La soglia di presa è schematizzata idraulicamente come uno stramazzo rigurgitato, che è governato dall'espressione: 2 Q = L ⋅ µ1 ⋅ h2 ⋅ 2 g ⋅ h1 + ⋅ µ 2 ⋅ h1 ⋅ 2 g ⋅ h1 3 con: - Q L µ1 = µ2 = 0,65 h1 h2 = h - h1 h = 1,70 m g = 9,81 m/s2 portata; larghezza; coefficiente di portata (Schoklitsch); altezza della vena libera (perdita di carico); altezza della vena rigurgitata; altezza idrometrica a monte accelerazione di gravità. La soluzione di questa equazione è raggiunta per via iterativa. Griglia di pulizia La perdita di carico localizzata presso la griglia di pulizia è calcolata attraverso la relazione di Kirschmer. La velocità della corrente a monte della griglia è: U12 ∆H = ξ ⋅ 2g dove - ∆H ξ U1 g = 9,81 m/s2 perdita di carico localizzata; coefficiente di forma; velocità della corrente a monte del paratronchi; accelerazione di gravità. Il coefficiente di forma è definito dall’espressione: Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 78 Relazione tecnica 4 s 3 ξ = k1 ⋅ ⋅ sen ϑ d in cui - k1 = 2,42 s = 0,008 m d = 0,042 m θ = 60° coefficiente (per facce squadrate); larghezza dell’asta; distanza netta tra le aste; inclinazione delle aste rispetto l’orizzon tale. Sostituendo i valori si ottiene: 0,008 ξ = 2,42 ⋅ 0,042 4 3 ⋅ sen 60° = 0,23 La velocità della corrente a monte della griglia è: U1 = Q Q = Ω 1 L ⋅ h1 h1 = H 1 − H f con - U1 Q L h1 velocità della corrente a monte; portata; larghezza della griglia; carico piezometrico. Il carico piezometrico è pari all'altezza della vena rigurgitata definita per la soglia di presa addizionata di 0,30 m, che rappresenta il dislivello tra la soglia d'imbocco del canale di adduzione ed il fondo presso la griglia: h1 griglia = h2 presa + 0,30 altezza della vena rigurgitata; 17.1.2. Turbina principale Il canale di adduzione è largo 6,00 m. Con la portata massima d'esercizio di 10,000 m3/s si ottiene una perdita di carico presso la soglia di presa pari a 0,122 m. Sostituendo i valori nelle espressioni indicate sia per la soglia di presa sia per la griglia di pulizia si ottiene: h2 = 1,70 − 0,122 = 1,578 m 2 Q = 6,00 ⋅ 0,65 ⋅1,578 ⋅ 2 g ⋅ 0,122 + ⋅ 0,65 ⋅ 0,122 ⋅ 2 g ⋅ 0,122 = 10,000 m3 s 3 h1 = 1,578 + 0,30 = 1,878 m U1 = 10,000 = 0,89 m s 6,00 ⋅1,878 0,892 ∆H = 0, 23 ⋅ = 0,009 m 2g H 2 = H1 − h1 − ∆H = 374,95 − 0,122 − 0,009 = 374,819 m s.l.m. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 79 Relazione tecnica La successiva Tabella 15 riporta i valori di quota idrometrica calcolati nel bacino di carico della furbina idraulica per ciascun valore delle curve mensili di durata delle portate derivabili Tabella 15: Quote idrometriche nel bacino di carico (m s.l.m.) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Gen Feb Mar 374,93 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,92 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,85 374,87 374,88 374,89 374,89 374,90 374,90 374,90 374,90 374,91 374,92 374,92 374,92 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,93 Apr 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,83 374,84 374,84 374,85 374,86 374,86 374,86 374,87 374,87 374,88 374,89 374,89 Mag 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,83 374,84 374,84 374,84 374,84 374,85 374,85 374,86 374,86 374,86 374,88 374,89 374,90 374,90 374,91 Giu 374,82 374,82 374,84 374,86 374,87 374,87 374,88 374,89 374,90 374,90 374,91 374,91 374,91 374,91 374,91 374,92 374,92 374,92 374,92 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 Lug 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Ago 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Set 374,91 374,92 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Ott 374,82 374,93 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Nov 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,82 374,86 374,88 374,90 374,91 374,91 374,92 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 Dic 374,83 374,89 374,91 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 80 Relazione tecnica 17.1.3. Turbina di rilascio del deflusso minimo vitale Il canale di adduzione è largo 3,50 m. Con la portata massima d'esercizio di 4,000 m3/s si ottiene una perdita di carico presso la soglia di presa pari a 0,056 m. Sostituendo i valori nelle espressioni indicate sia per la soglia di presa sia per la griglia di pulizia si ottiene: h2 = 1,70 − 0,056 = 1,644 m 2 Q = 3,50 ⋅ 0,65 ⋅1,644 ⋅ 2 g ⋅ 0,056 + ⋅ 0,65 ⋅ 0,056 ⋅ 2 g ⋅ 0,056 = 4,000 m3 s 3 h1 = 1,644 + 0,30 = 1,944 m U1 = 4,000 = 0,59 m s 3,50 ⋅1,944 0,59 2 ∆H = 0,23 ⋅ = 0,004 m 2g H 2 = H1 − h1 − ∆H = 374,95 − 0,056 − 0,004 = 374,890 m s.l.m. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 81 Relazione tecnica La successiva Tabella 16 riporta i valori di quota idrometrica calcolati nel bacino di carico della furbina idraulica per ciascun valore delle curve mensili di durata delle portate derivabili Tabella 16: Quote idrometriche nel bacino di carico (m s.l.m.) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Gen Feb Mar 374,94 374,94 374,94 374,94 374,94 374,95 374,89 374,90 374,90 374,90 374,90 374,91 374,91 374,91 374,91 374,91 374,92 374,92 374,92 374,92 374,92 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,89 374,89 374,90 374,90 374,90 374,91 374,91 374,91 374,91 374,91 374,92 374,92 374,92 374,92 374,92 374,92 374,92 374,92 374,92 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,90 374,91 374,92 374,92 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 17.2. Apr 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,90 374,90 374,90 374,90 374,91 374,91 374,91 374,91 374,91 374,92 374,92 374,92 Mag 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,90 374,90 374,90 374,90 374,90 374,90 374,91 374,91 374,91 374,91 374,92 374,92 374,93 374,93 374,93 Giu 374,89 374,89 374,90 374,91 374,91 374,92 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,89 374,90 374,90 Lug 374,94 374,89 374,90 374,90 374,91 374,91 374,91 374,92 374,92 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 Ago 374,91 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Set 374,93 374,94 374,94 374,92 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Ott 374,89 374,94 374,94 374,91 374,92 374,92 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 374,95 Nov 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,89 374,91 374,92 374,93 374,93 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,89 374,90 374,92 374,92 374,92 Dic 374,89 374,92 374,93 374,93 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,94 374,95 374,89 374,90 374,91 374,91 374,91 374,91 374,91 374,92 374,92 374,92 374,92 374,92 374,92 374,93 374,93 Quota idrometrica a valle Il calcolo della quota idrometrica a valle delle turbine idrauliche è svolto con metodo numerico attraverso il codice di calcolo informatico Hec-Ras. Il modello idraulico è quello utilizzato per le verifiche del torrente Corsaglia contenute nell'elaborato progettuale 22 "Compatibilità con il PAI". L'altezza idrometrica a valle delle turbine è considerata in modo univoco coincidente con quella presente nella platea a valle della traversa, in cui è localizzato lo scarico dell'impianto di valorizzazione energetica del deflusso minimo vitale. L'altro scarico è ubicato più a valle , ma la distanza è minima e la pendenza dell'alveo è ridotta, così è possibile ipotizzare con buona approssimazione che il livello idraulico coincida. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 82 Relazione tecnica Con la portata disponibile minima che consente la derivazione massima d'esercizio di entrambe le turbine idrauliche si ottiene (Qdisp = 14,128 m3/s; Qder = 14,000 m3/s) si calcola un carico idraulico pari a 370,06 m s.l.m.. La successiva Tabella 17 riporta i valori di quota idrometrica calcolati presso lo scarico delle turbine per ciascun valore delle curve mensili di durata delle portate derivabili Tabella 17: Quote idrometriche presso lo scarico (m s.l.m.) Durata (gg) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Gen Feb Mar 369,68 369,66 369,61 369,59 369,58 369,58 369,57 369,56 369,56 369,55 369,54 369,52 369,52 369,51 369,51 369,50 369,50 369,49 369,49 369,48 369,48 369,47 369,47 369,46 369,46 369,46 369,46 369,45 369,45 369,45 369,44 369,76 369,73 369,71 369,68 369,64 369,61 369,60 369,60 369,58 369,57 369,57 369,56 369,55 369,54 369,53 369,52 369,51 369,51 369,51 369,50 369,50 369,49 369,49 369,48 369,48 369,48 369,47 369,47 370,44 370,28 370,26 370,17 370,15 370,14 370,12 370,07 370,06 370,05 369,99 369,96 369,92 369,90 369,89 369,88 369,87 369,86 369,85 369,82 369,80 369,79 369,77 369,76 369,75 369,74 369,73 369,73 369,72 369,72 369,71 Apr 370,83 370,65 370,53 370,52 370,43 370,35 370,33 370,30 370,25 370,23 370,19 370,18 370,17 370,13 370,10 370,09 370,08 370,05 370,04 370,02 370,01 370,00 369,99 369,98 369,97 369,96 369,95 369,94 369,91 369,90 Mag 370,56 370,49 370,36 370,31 370,28 370,23 370,21 370,18 370,16 370,15 370,14 370,13 370,11 370,10 370,08 370,05 370,04 370,03 370,02 370,02 370,01 370,00 369,99 369,99 369,98 369,97 369,92 369,89 369,88 369,86 369,83 Giu 370,13 370,06 370,02 369,98 369,96 369,94 369,93 369,91 369,88 369,85 369,84 369,84 369,83 369,82 369,81 369,80 369,80 369,79 369,76 369,73 369,70 369,68 369,64 369,63 369,60 369,59 369,58 369,57 369,56 369,55 Lug 369,59 369,57 369,56 369,54 369,53 369,51 369,50 369,47 369,47 369,46 369,46 369,45 369,44 369,43 369,42 369,42 369,41 369,41 369,40 369,39 369,38 369,38 369,38 369,37 369,36 369,35 369,35 369,34 369,34 369,33 369,32 Ago 369,53 369,46 369,38 369,37 369,37 369,36 369,36 369,35 369,34 369,34 369,33 369,33 369,33 369,32 369,32 369,32 369,31 369,31 369,31 369,31 369,30 369,30 369,30 369,29 369,29 369,29 369,29 369,28 369,27 369,27 369,26 Set 369,84 369,77 369,59 369,47 369,41 369,40 369,39 369,38 369,36 369,35 369,35 369,34 369,33 369,33 369,32 369,30 369,29 369,29 369,29 369,28 369,27 369,27 369,27 369,27 369,26 369,26 369,26 369,26 369,26 369,25 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Ott 370,12 369,72 369,58 369,51 369,49 369,47 369,45 369,41 369,41 369,40 369,37 369,36 369,35 369,34 369,34 369,33 369,33 369,33 369,33 369,33 369,32 369,32 369,31 369,31 369,30 369,30 369,30 369,30 369,29 369,29 369,28 Nov 371,57 371,09 370,75 370,56 370,45 370,25 370,10 370,05 369,97 369,92 369,87 369,84 369,83 369,80 369,78 369,75 369,74 369,73 369,72 369,69 369,66 369,64 369,61 369,59 369,58 369,57 369,56 369,50 369,49 369,48 Dic 370,04 369,90 369,83 369,80 369,76 369,74 369,71 369,69 369,68 369,66 369,65 369,64 369,61 369,60 369,59 369,58 369,57 369,54 369,53 369,52 369,52 369,52 369,51 369,50 369,49 369,48 369,48 369,47 369,47 369,46 369,46 83 Relazione tecnica 17.3. Salto idraulico Il salto idraulico è calcolato per ciascuna turbina come dislivello tra l'altezza piezometrica nel bacino di carico e quella presso lo scarico. 17.3.1. Turbina principale Con la portata massima derivabile i livelli sono: H1 = 374,82 m s.l.m.; H2 = 370,06 m s.l.m.; Pertanto si ottiene: h = 374,82 − 370,06 = 4,76 m La successiva Tabella 18 riporta i valori di salto idraulico per ciascun valore delle curve mensili di durata delle portate derivabili Tabella 18: Salto idraulico (m) Durata Gen Feb Mar (gg) 1 5,25 5,16 4,38 2 5,28 5,20 4,54 3 5,33 5,22 4,56 4 5,35 5,25 4,65 5 5,36 5,30 4,67 6 5,36 5,33 4,68 7 5,38 5,34 4,70 8 5,39 5,34 4,75 9 5,39 5,36 4,76 10 5,40 5,38 4,77 11 5,41 5,38 4,86 12 5,43 5,39 4,91 13 5,43 5,40 4,96 14 5,44 5,41 4,99 15 5,44 5,42 5,00 16 5,45 5,43 5,02 17 5,45 5,44 5,03 18 5,46 5,44 5,04 19 5,46 5,44 5,05 20 5,47 5,45 5,09 21 5,47 5,45 5,12 22 5,48 5,46 5,13 23 5,48 5,46 5,15 24 5,49 5,47 5,16 25 5,49 5,47 5,17 26 5,49 5,47 5,19 27 5,49 5,48 5,20 28 5,50 5,48 5,20 29 5,50 5,21 30 5,50 5,21 31 5,51 5,22 Apr 3,99 4,17 4,29 4,30 4,39 4,47 4,49 4,52 4,57 4,59 4,63 4,64 4,65 4,69 4,72 4,73 4,74 4,77 4,79 4,82 4,83 4,85 4,87 4,88 4,89 4,91 4,92 4,94 4,98 4,99 Mag 4,26 4,33 4,46 4,51 4,54 4,59 4,61 4,64 4,66 4,67 4,68 4,69 4,71 4,72 4,74 4,77 4,79 4,81 4,82 4,82 4,83 4,85 4,86 4,87 4,88 4,89 4,96 5,00 5,02 5,04 5,08 Giu 4,69 4,76 4,82 4,88 4,91 4,93 4,95 4,98 5,02 5,05 5,07 5,07 5,08 5,09 5,10 5,12 5,12 5,13 5,16 5,20 5,23 5,25 5,30 5,31 5,34 5,35 5,36 5,38 5,39 5,40 Lug 5,35 5,38 5,39 5,41 5,42 5,44 5,45 5,48 5,48 5,49 5,49 5,50 5,51 5,52 5,53 5,53 5,54 5,54 5,55 5,56 5,57 5,57 5,57 5,58 5,59 5,60 5,60 5,61 5,61 5,62 5,63 Ago 5,42 5,49 5,57 5,58 5,58 5,59 5,59 5,60 5,61 5,61 5,62 5,62 5,62 5,63 5,63 5,63 5,64 5,64 5,64 5,64 5,65 5,65 5,65 5,66 5,66 5,66 5,66 5,67 5,68 5,68 5,69 Set 5,07 5,15 5,35 5,48 5,54 5,55 5,56 5,57 5,59 5,60 5,60 5,61 5,62 5,62 5,63 5,65 5,66 5,66 5,66 5,67 5,68 5,68 5,68 5,68 5,69 5,69 5,69 5,69 5,69 5,70 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Ott 4,70 5,21 5,36 5,44 5,46 5,48 5,50 5,54 5,54 5,55 5,58 5,59 5,60 5,61 5,61 5,62 5,62 5,62 5,62 5,62 5,63 5,63 5,64 5,64 5,65 5,65 5,65 5,65 5,66 5,66 5,67 Nov 3,25 3,73 4,07 4,26 4,37 4,57 4,72 4,77 4,89 4,96 5,03 5,07 5,08 5,12 5,14 5,17 5,19 5,20 5,21 5,24 5,27 5,30 5,33 5,35 5,36 5,38 5,39 5,45 5,46 5,47 Dic 4,79 4,99 5,08 5,12 5,16 5,19 5,22 5,24 5,25 5,27 5,29 5,30 5,33 5,34 5,35 5,36 5,38 5,41 5,42 5,43 5,43 5,43 5,44 5,45 5,46 5,47 5,47 5,48 5,48 5,49 5,49 84 Relazione tecnica 17.3.2. Turbina di rilascio del deflusso minimo vitale Con la portata massima derivabile i livelli sono: H1 = 374,89 m s.l.m.; H2 = 370,06 m s.l.m.; Pertanto si ottiene: h = 374,89 − 370,06 = 4,83 m La successiva Tabella 19 riporta i valori di salto idraulico per ciascun valore delle curve mensili di durata delle portate derivabili Tabella 19: Salto idraulico (m) Durata Gen Feb Mar (gg) 1 5,26 5,18 4,45 2 5,28 5,21 4,61 3 5,33 5,23 4,63 4 5,35 5,26 4,72 5 5,36 5,30 4,74 6 5,37 5,33 4,75 7 5,32 5,34 4,77 8 5,34 5,34 4,82 9 5,34 5,36 4,83 10 5,35 5,32 4,84 11 5,36 5,32 4,91 12 5,39 5,34 4,95 13 5,39 5,35 5,00 14 5,40 5,36 5,02 15 5,40 5,38 5,03 16 5,41 5,39 5,04 17 5,42 5,40 5,06 18 5,43 5,40 5,07 19 5,43 5,40 5,08 20 5,44 5,42 5,11 21 5,44 5,42 5,13 22 5,45 5,43 5,15 23 5,45 5,43 5,17 24 5,47 5,44 5,18 25 5,47 5,44 5,19 26 5,47 5,44 5,20 27 5,47 5,45 5,21 28 5,48 5,45 5,21 29 5,48 5,22 30 5,48 5,22 31 5,49 5,23 Apr 4,06 4,24 4,36 4,37 4,46 4,54 4,56 4,59 4,64 4,66 4,70 4,71 4,72 4,76 4,79 4,80 4,81 4,84 4,86 4,88 4,89 4,90 4,92 4,93 4,94 4,95 4,96 4,98 5,01 5,02 Mag 4,33 4,40 4,53 4,58 4,61 4,66 4,68 4,71 4,73 4,74 4,75 4,76 4,78 4,79 4,81 4,84 4,86 4,87 4,88 4,88 4,89 4,90 4,92 4,92 4,93 4,94 5,00 5,03 5,05 5,07 5,10 Giu 4,76 4,83 4,88 4,93 4,95 4,98 4,99 5,01 5,05 5,08 5,09 5,09 5,10 5,11 5,12 5,13 5,13 5,15 5,18 5,21 5,24 5,26 5,30 5,31 5,34 5,35 5,37 5,32 5,34 5,35 Lug 5,35 5,32 5,34 5,36 5,38 5,40 5,41 5,45 5,45 5,47 5,47 5,48 5,49 5,50 5,51 5,51 5,52 5,53 5,54 5,55 5,56 5,56 5,56 5,57 5,58 5,59 5,59 5,60 5,60 5,61 5,62 Ago 5,38 5,47 5,56 5,57 5,57 5,58 5,58 5,59 5,60 5,60 5,61 5,61 5,61 5,62 5,63 5,63 5,64 5,64 5,64 5,64 5,65 5,65 5,65 5,66 5,66 5,66 5,66 5,67 5,68 5,68 5,69 Set 5,09 5,17 5,35 5,45 5,52 5,54 5,55 5,56 5,58 5,59 5,59 5,60 5,61 5,61 5,63 5,65 5,66 5,66 5,66 5,67 5,68 5,68 5,68 5,68 5,69 5,69 5,69 5,69 5,69 5,70 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) Ott 4,77 5,22 5,36 5,40 5,43 5,45 5,48 5,52 5,52 5,54 5,57 5,58 5,59 5,60 5,60 5,61 5,61 5,61 5,61 5,61 5,62 5,63 5,64 5,64 5,65 5,65 5,65 5,65 5,66 5,66 5,67 Nov 3,32 3,80 4,14 4,33 4,44 4,64 4,79 4,84 4,94 5,00 5,06 5,09 5,10 5,13 5,16 5,19 5,20 5,21 5,22 5,25 5,28 5,30 5,33 5,35 5,37 5,32 5,34 5,42 5,43 5,44 Dic 4,85 5,02 5,10 5,13 5,18 5,20 5,23 5,25 5,26 5,28 5,29 5,30 5,33 5,34 5,35 5,37 5,32 5,36 5,38 5,39 5,39 5,39 5,40 5,42 5,43 5,44 5,44 5,45 5,45 5,47 5,47 85 Relazione tecnica 18. PRODUZIONE Di seguito si determina la produzione di energia dell’anno idrologico medio. L’energia prodotta si calcola con la seguente espressione: P = η ⋅γ ⋅Q ⋅ h E = P ⋅t dove - E P η = 83% γ = 9,81 kN/m3 Q h t energia; potenza; rendimento dell’impianto; peso specifico dell’acqua; portata; salto idraulico; tempo di funzionamento. Le tabelle successive riassumono le potenze e le produzioni medie giornaliere per i periodi in cui è previsto l’esercizio dell’impianto. L’impianto in progetto produce mediamente nell’anno: turbina principale 886˙743 kWh; turbina DMV 1˙177˙850 kWh; impianto complessivo 2˙064˙593 kWh. Nelle pagine che seguono sono indicati i vari valori di potenza ed energia prodotti dalle singole turbine organizzati sulla base delle relative curve di durata delle portate derivabili. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 86 Relazione tecnica 18.1. Impianto principale Tabella 20: Curve di durata della potenza (kW) Durata Media Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov Dic 1 2 159 149 195 181 357 370 325 339 347 352 382 387 133 0 0 0 239 198 383 174 265 304 379 283 3 4 5 6 7 8 137 132 129 126 0 0 172 159 145 139 136 133 371 379 380 381 383 387 349 350 357 364 366 368 363 367 370 374 375 378 362 338 322 308 302 289 0 0 0 0 0 0 0 0 0 0 0 0 133 0 0 0 0 0 128 0 0 0 0 0 331 347 356 372 384 385 233 217 194 186 169 161 9 10 0 0 128 0 387 384 372 374 379 380 265 250 0 0 0 0 0 0 0 0 330 295 157 152 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 345 322 294 282 274 267 263 253 246 228 218 210 200 195 190 185 181 179 177 173 169 377 378 379 382 384 385 386 385 373 361 357 347 339 331 325 320 317 306 289 283 381 382 383 384 386 388 374 367 363 359 355 352 343 338 331 327 297 274 264 254 237 245 239 235 230 222 219 217 208 192 179 168 156 145 141 134 131 126 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 262 243 233 216 206 191 183 179 173 160 152 142 137 131 127 0 0 0 0 0 145 142 141 134 130 126 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 27 50 278 352 349 213 4 0 19 22 203 95 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 87 Relazione tecnica Tabella 21: Curve di durata dell’energia prodotta (kWh) Durata Gen 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 3 805 3 572 3 296 3 159 3 090 3 016 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Feb Mar Apr 4 691 4 335 4 131 3 818 3 477 3 337 3 267 3 198 3 075 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 557 8 870 8 909 9 085 9 124 9 144 9 183 9 280 9 300 9 207 8 284 7 726 7 049 6 758 6 585 6 401 6 305 6 081 5 907 5 480 5 232 5 030 4 809 4 690 4 549 4 446 4 341 4 307 4 247 4 163 4 050 7 795 8 147 8 382 8 401 8 577 8 733 8 772 8 831 8 929 8 968 9 046 9 065 9 085 9 163 9 222 9 241 9 261 9 247 8 952 8 663 8 566 8 321 8 139 7 943 7 807 7 685 7 596 7 350 6 938 6 800 Mag 8 323 8 460 8 714 8 811 8 870 8 968 9 007 9 065 9 105 9 124 9 144 9 163 9 202 9 222 9 261 9 304 8 976 8 798 8 714 8 615 8 515 8 442 8 243 8 122 7 956 7 853 7 134 6 569 6 345 6 103 5 683 Giu Lug Ago 9 163 3 191 9 300 0 8 689 0 8 105 0 7 734 0 7 398 0 7 258 0 6 942 0 6 368 0 5 996 0 5 873 0 5 737 0 5 635 0 5 531 0 5 332 0 5 258 0 5 203 0 4 996 0 4 597 0 4 299 0 4 025 0 3 753 0 3 487 0 3 385 0 3 227 0 3 141 0 3 035 0 0 0 0 0 0 0 0 Totale 19 939 33 329 207 101 253 627 259 809 153 469 3 191 Set Ott 0 5 748 9 183 0 4 743 4 185 0 3 188 3 067 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Nov Dic 6 349 7 287 7 952 8 323 8 538 8 929 9 222 9 247 7 909 7 079 6 278 5 838 5 582 5 196 4 940 4 577 4 398 4 302 4 159 3 851 3 645 3 415 3 294 3 145 3 055 0 0 0 0 0 9 098 6 781 5 597 5 205 4 667 4 461 4 047 3 870 3 772 3 653 3 478 3 410 3 374 3 217 3 111 3 019 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13 679 16 435 146 510 70 761 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 88 Relazione tecnica 18.2. Impianto di rilascio e valorizzazione energetica del DMV Tabella 22: Curve di durata della potenza (kW) Durata Media Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov Dic 1 2 64 60 78 72 145 150 132 138 141 143 155 157 53 171 151 112 96 79 155 70 108 124 154 114 3 4 5 6 7 8 55 53 52 50 170 166 69 64 58 56 55 53 151 154 154 155 155 157 142 142 145 148 149 149 148 149 150 152 152 153 147 136 130 124 122 117 164 152 147 140 136 121 79 75 72 70 68 66 53 119 92 86 81 78 51 137 127 120 112 94 135 141 145 151 156 156 94 87 78 75 68 65 9 10 163 161 51 173 157 156 151 152 154 154 107 100 117 114 62 61 72 66 91 86 133 119 63 61 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 155 145 143 140 138 136 133 130 127 127 122 119 117 116 114 113 112 111 110 108 104 168 163 159 156 148 144 141 139 138 136 133 129 127 125 122 122 120 117 140 130 118 113 110 107 106 102 99 92 88 84 80 78 76 74 73 72 71 70 68 153 153 154 155 156 156 157 156 151 146 144 140 137 134 131 129 128 123 116 114 155 155 156 156 157 157 152 149 147 145 144 142 139 137 134 132 120 110 106 102 95 98 96 94 93 89 88 87 84 77 72 67 63 58 56 54 52 51 171 165 159 113 108 104 101 98 96 93 90 87 84 80 79 76 74 68 67 64 63 61 59 55 59 57 55 54 53 51 51 50 49 48 46 45 44 43 41 41 40 38 34 32 29 65 61 58 56 53 45 42 39 38 37 34 33 32 30 30 30 29 0 0 0 72 69 64 63 60 58 58 58 57 55 54 51 49 48 46 46 45 44 40 38 36 105 98 93 87 83 76 73 72 69 64 61 57 55 52 51 171 165 133 129 124 58 57 56 54 52 50 169 156 152 145 144 142 138 135 129 126 125 121 117 114 112 117 115 112 143 142 102 98 57 51 69 106 104 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 89 Relazione tecnica Tabella 23: Curve di durata dell’energia prodotta (kWh) Durata Gen 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 525 1 431 1 320 1 265 1 237 1 208 4 073 3 990 3 902 3 872 3 720 3 491 3 422 3 363 3 316 3 268 3 198 3 125 3 053 3 038 2 925 2 853 2 799 2 777 2 740 2 710 2 692 2 661 2 638 2 581 2 496 Feb Mar Apr 1 882 1 738 1 656 1 530 1 393 1 337 1 308 1 281 1 231 4 143 4 040 3 920 3 812 3 738 3 542 3 464 3 374 3 345 3 311 3 255 3 187 3 094 3 060 3 011 2 939 2 916 2 871 2 812 3 479 3 604 3 619 3 690 3 705 3 713 3 729 3 768 3 776 3 736 3 350 3 119 2 840 2 721 2 650 2 575 2 536 2 445 2 374 2 201 2 100 2 018 1 929 1 881 1 825 1 783 1 741 1 727 1 703 1 669 1 623 3 174 3 314 3 408 3 416 3 486 3 549 3 565 3 588 3 627 3 643 3 674 3 682 3 690 3 721 3 744 3 752 3 760 3 753 3 629 3 508 3 467 3 365 3 290 3 209 3 152 3 102 3 065 2 964 2 795 2 738 Mag 3 385 3 439 3 541 3 580 3 604 3 643 3 658 3 682 3 697 3 705 3 713 3 721 3 737 3 744 3 760 3 777 3 639 3 564 3 529 3 488 3 446 3 415 3 333 3 283 3 214 3 171 2 875 2 644 2 552 2 454 2 283 Giu Lug Ago Set Ott Nov Dic 3 721 3 776 3 519 3 275 3 122 2 983 2 926 2 796 2 562 2 410 2 360 2 305 2 263 2 222 2 141 2 111 2 089 2 005 1 844 1 724 1 613 1 504 1 397 1 356 1 292 1 258 1 215 4 094 3 963 3 821 1 278 4 101 3 930 3 655 3 535 3 369 3 268 2 914 2 803 2 742 2 705 2 603 2 495 2 429 2 350 2 293 2 241 2 163 2 092 2 027 1 923 1 895 1 828 1 770 1 635 1 601 1 544 1 505 1 453 1 416 1 309 3 626 2 694 1 895 1 794 1 726 1 675 1 638 1 580 1 491 1 458 1 413 1 373 1 331 1 302 1 265 1 231 1 215 1 205 1 167 1 148 1 115 1 072 1 046 1 022 996 984 955 909 823 763 692 2 309 1 903 1 277 2 855 2 207 2 053 1 950 1 863 1 722 1 587 1 556 1 462 1 390 1 335 1 274 1 079 1 003 936 915 881 820 782 760 725 721 712 695 0 0 0 3 729 1 678 1 228 3 293 3 042 2 890 2 683 2 249 2 184 2 070 1 731 1 659 1 528 1 512 1 449 1 400 1 385 1 381 1 357 1 324 1 308 1 225 1 175 1 142 1 108 1 101 1 077 1 047 965 915 869 2 595 2 970 3 236 3 385 3 471 3 627 3 744 3 753 3 194 2 853 2 525 2 346 2 242 2 086 1 982 1 836 1 763 1 725 1 667 1 543 1 460 1 368 1 319 1 259 1 223 4 099 3 968 3 194 3 085 2 968 3 690 2 730 2 248 2 089 1 872 1 789 1 622 1 551 1 511 1 463 1 393 1 366 1 351 1 288 1 246 1 209 4 055 3 755 3 645 3 475 3 455 3 401 3 307 3 237 3 094 3 027 2 998 2 910 2 815 2 742 2 692 Totale 86 688 77 189 83 627 102 829 105 276 73 667 72 871 42 603 36 770 51 705 76 488 77 028 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 90 Relazione tecnica 18.3. Impianto complessivo Tabella 24: Curve di durata della potenza (kW) Durata Media Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov Dic 1 2 222 208 274 253 501 520 457 478 488 496 537 545 186 171 151 112 336 277 538 244 373 427 533 396 3 4 5 6 7 8 192 184 180 176 170 166 241 223 203 195 191 187 522 532 535 536 538 544 491 492 503 512 514 517 511 516 520 525 528 531 509 474 452 433 424 406 164 152 147 140 136 121 79 75 72 70 68 66 186 119 92 86 81 78 179 137 127 120 112 94 466 488 500 523 540 542 327 304 272 260 236 226 9 10 163 161 179 173 545 539 523 525 533 535 372 350 117 114 62 61 72 66 91 86 463 414 220 213 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 155 145 143 140 138 136 133 130 127 127 122 119 117 116 114 113 112 111 110 108 104 168 163 159 156 148 144 141 139 138 136 133 129 127 125 122 122 120 117 485 452 412 395 385 374 368 355 345 320 306 294 281 274 266 260 253 251 248 243 236 530 531 532 537 540 541 543 542 524 507 501 487 476 465 457 449 444 430 406 397 536 537 539 540 543 545 526 515 510 504 498 494 482 475 465 459 417 384 371 357 332 343 335 329 323 311 307 304 292 268 251 235 219 204 198 188 183 177 171 165 159 113 108 104 101 98 96 93 90 87 84 80 79 76 74 68 67 64 63 61 59 55 59 57 55 54 53 51 51 50 49 48 46 45 44 43 41 41 40 38 34 32 29 65 61 58 56 53 45 42 39 38 37 34 33 32 30 30 30 29 0 0 0 72 69 64 63 60 58 58 58 57 55 54 51 49 48 46 46 45 44 40 38 36 367 341 326 303 288 267 257 251 243 225 213 199 192 184 178 171 165 133 129 124 203 199 197 188 182 176 169 156 152 145 144 142 138 135 129 126 125 121 117 114 112 143 164 391 495 491 315 102 57 70 92 310 199 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 91 Relazione tecnica Tabella 25: Curve di durata dell’energia prodotta (kWh) Durata 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Gen Feb 5 330 5 004 4 616 4 425 4 327 4 224 4 073 3 990 3 902 3 872 3 720 3 491 3 422 3 363 3 316 3 268 3 198 3 125 3 053 3 038 2 925 2 853 2 799 2 777 2 740 2 710 2 692 2 661 2 638 2 581 2 496 6 573 6 073 5 787 5 348 4 869 4 674 4 575 4 479 4 307 4 143 4 040 3 920 3 812 3 738 3 542 3 464 3 374 3 345 3 311 3 255 3 187 3 094 3 060 3 011 2 939 2 916 2 871 2 812 Mar 12 036 12 474 12 528 12 775 12 829 12 857 12 911 13 048 13 076 12 944 11 633 10 845 9 889 9 479 9 236 8 976 8 840 8 526 8 281 7 681 7 333 7 048 6 739 6 571 6 374 6 228 6 082 6 034 5 950 5 832 5 673 Apr Mag Giu Lug Ago Set Ott 10 969 11 461 11 790 11 817 12 063 12 282 12 337 12 419 12 556 12 611 12 720 12 747 12 775 12 884 12 966 12 994 13 021 12 999 12 581 12 171 12 034 11 686 11 429 11 152 10 959 10 786 10 661 10 314 9 733 9 539 11 708 11 899 12 255 12 392 12 474 12 611 12 665 12 747 12 802 12 829 12 857 12 884 12 939 12 966 13 021 13 081 12 615 12 362 12 243 12 102 11 961 11 857 11 575 11 405 11 169 11 024 10 009 9 213 8 897 8 557 7 966 12 884 13 076 12 208 11 381 10 856 10 381 10 184 9 739 8 930 8 406 8 234 8 043 7 898 7 753 7 473 7 369 7 292 7 001 6 441 6 023 5 638 5 257 4 884 4 740 4 519 4 399 4 250 4 094 3 963 3 821 4 469 4 101 3 930 3 655 3 535 3 369 3 268 2 914 2 803 2 742 2 705 2 603 2 495 2 429 2 350 2 293 2 241 2 163 2 092 2 027 1 923 1 895 1 828 1 770 1 635 1 601 1 544 1 505 1 453 1 416 1 309 3 626 2 694 1 895 1 794 1 726 1 675 1 638 1 580 1 491 1 458 1 413 1 373 1 331 1 302 1 265 1 231 1 215 1 205 1 167 1 148 1 115 1 072 1 046 1 022 996 984 955 909 823 763 692 8 057 12 911 6 646 5 863 4 464 4 296 2 855 3 293 2 207 3 042 2 053 2 890 1 950 2 683 1 863 2 249 1 722 2 184 1 587 2 070 1 556 1 731 1 462 1 659 1 390 1 528 1 335 1 512 1 274 1 449 1 079 1 400 1 003 1 385 936 1 381 915 1 357 881 1 324 820 1 308 782 1 225 760 1 175 725 1 142 721 1 108 712 1 101 695 1 077 0 1 047 0 965 0 915 869 Nov Dic 8 945 12 788 10 258 9 512 11 188 7 846 11 708 7 294 12 009 6 538 12 556 6 250 12 966 5 669 12 999 5 421 11 103 5 284 9 932 5 116 8 803 4 871 8 184 4 776 7 825 4 725 7 282 4 506 6 923 4 357 6 413 4 228 6 161 4 055 6 027 3 755 5 826 3 645 5 394 3 475 5 105 3 455 4 783 3 401 4 613 3 307 4 404 3 237 4 278 3 094 4 099 3 027 3 968 2 998 3 194 2 910 3 085 2 815 2 968 2 742 2 692 Totale 106 627 110 518 290 728 356 456 365 086 227 136 76 062 42 603 50 449 68 140 222 997 147 789 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 92 Relazione tecnica Estrapolando i valori mensili si ottengono la Tabella 26 ed il Grafico 7 che seguono. Tabella 26: Produzioni medie mensili Periodo 3 Q (m /s) P (kW) E (kWh) Gen Feb Mar Apr Mag Giu Lug Ago Set Ott Nov Dic 3,266 3,782 9,823 13,030 12,713 7,681 2,296 1,259 1,587 2,108 8,034 4,661 143 164 391 495 491 315 102 57 70 92 310 199 106 627 110 518 290 728 356 456 365 086 227 136 76 062 42 603 50 449 68 140 222 997 147 789 Anno 5,851 236 2 064 593 Grafico 7: Distribuzione della produzione di energia Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 93 Relazione tecnica 19. SCELTA DELLE TURBINE E POTENZE INSTALLATE E NOMINALI 19.1. Scelta delle turbine da installare Le turbine installate nell’impianto idroelettrico in progetto sono in grado di operare con portate comprese nei seguenti intervalli: turbina principale Q1 ∈ 1,500; 10,000 m3/s; - [ ] Q 2 ∈ [0,600; 4,000] m /s. 3 turbina DMV La grandezza che indica il tipo di turbina da adottare è la velocità specifica che si calcola con la formula: ωs = ω ⋅ Q (g ⋅ hu ) 4 3 = 2π ⋅ n ⋅ Q ( g ⋅ hu ) 4 3 dove: - n Q g = 9,81 m/s2 h velocità di rotazione di regime della turbina; portata massima; accelerazione di gravità; salto idraulico. Per la turbina principale si hanno i seguenti parametri: n = 5 giri/s velocità di rotazione di regime della turbina (300 giri/min); 3 Q = 10,000 m /s portata massima; h = 4,76 m salto idraulico. Per la turbina di rilascio e valorizzazione energetica del deflusso minimo vitale si ha: n = 8,33 giri/s velocità di rotazione di regime della turbina (500 giri/min); 3 Q = 4,000 m /s portata massima; h = 4,83 m salto idraulico. Sostituendo i valori nell’espressione si ottiene: ω 1 = 2π ⋅ 5 ⋅ 10 ,000 ( g ⋅ 4 ,76 ) ω 2 = 2π ⋅ 8,33 ⋅ 3 = 5,56 rad s 4 4 , 000 (g ⋅ 4 ,83 ) 3 = 5,80 rad s 4 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 94 Relazione tecnica Di seguito si riporta la tabella 11.3 del libro “Fondamenti di macchine – Signum scuola - Torino 1997”. Tabella 27: Velocità specifiche caratteristiche di ogni tipo di turbina (rad/s) Tipo di turbina Pelton a un getto Velocità specifica Limite inferiore Valore centrale 0,03 0,07 Pelton a tre getti Francis lenta 0,1 0,25 1,1 Francis veloce 1,6 1,7 2,5 2,5 Kaplan a sei pale 3,2 Kaplan a cinque pale 3,8 Kaplan a quattro pale 4,3 A elica 0,35 0,6 Francis normale Kaplan a otto pale Limite superiore 4,6 6 10 Tenuto conto della tabella, si decide di installare le seguenti turbine idrauliche: turbina principale turbina Kaplan biregolante ad asse verticale, con distributore radiale in camera forzata e girante a quattro pale; la turbina è accoppiata ad un generatore sincrono a magneti indotti; - 19.2. turbina di rilascio e valorizzazione energetica del deflusso minimo vitale turbina Kaplan biregolante ad asse verticale, con distributore radiale in camera libera e girante a quattro pale; la turbina è accoppiata ad un generatore sincrono a magneti permanenti. Salto idraulico medio Il salto idraulico a disposizione delle turbine non è univoco, bensì esso cambia tra le macchine idrauliche e dipende anche dalla portata sia derivata sia presente in alveo. In conseguenza di ciò il salto idraulico medio (definito ai fini fiscali) è calcolato a ritroso in funzione della produzione annua dell'impianto: h= E η ⋅γ ⋅Q ⋅t dove - h E = 2˙064˙593 kW η = 83% γ = 9,81 kN/m3 Q = 5,851 m3/s t = 8760 h/anno salto idraulico; energia prodotta nell'anno idrologico medio; rendimento dell’impianto; peso specifico dell’acqua; portata derivata media annua; tempo di funzionamento. Sostituendo i vari valori si ottiene: h= E 2 064 593 = = 4,95 m η ⋅ γ ⋅ Q ⋅ t 0,83 ⋅ 9,81 ⋅ 5,851 ⋅ 8760 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 95 Relazione tecnica 19.3. Potenza dell'impianto e delle turbine La potenza delle turbine idrauliche è calcolata con l’espressione: P = η ⋅γ ⋅Q ⋅ h dove - P η γ = 9,81 kN/m3 Q h potenza; rendimento; peso specifico dell’acqua; portata; salto idraulico. 19.3.1. Potenza nominale La potenza nominale è definita trascurando il rendimento dei macchinari, pertanto il relativo coefficiente assume valore unitario. Ne consegue che le potenze nominali siano: impianto principale 3 Qmax = 10,000 m /s h(Qmax) = 4,76 m Pmax = 9,81 ⋅ 10,000 ⋅ 4,76 = 467 kW - impianto di rilascio e valorizzazione energetica del DMV Qmax = 4,000 m3/s h(Qmax) = 4,83 m Pmax = 9,81 ⋅ 4,000 ⋅ 4,83 = 190 kW - complessivo Qmed = 5,851 m3/s h(Qmed) = 4,95 m Pmed = 9,81 ⋅ 5,851 ⋅ 4,95 = 284 kW - Pmax = 467 + 190 = 656 kW 19.3.2. Potenza installata Per il calcolo della potenza della turbina idraulica installata bisogna tenere in considerazione il relativo rendimento, che è stimato pari a: impianto principale Qmax = 10,000 m3/s h(Qmax) = 4,76 m η = 88% Pmax = 0,88 ⋅ 9,81 ⋅ 10,000 ⋅ 4,76 = 411 kW - impianto di rilascio e valorizzazione energetica del DMV Qmax = 4,000 m3/s h(Qmax) = 4,83 m η = 88% Pmax = 0,88 ⋅ 9,81 ⋅ 4,000 ⋅ 4,83 = 167 kW - complessivo Pmax = 411 + 167 = 578 kW - Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 96 Relazione tecnica 20. ACCESSIBILITÀ E ORGANIZZAZIONE DI CANTIERE Gli elaborati planimetrici evidenziano l’esistente sistema viario principale e secondario della zona. L’arteria primaria è ovviamente costituita dalla S.S. 28 sud nel tratto compreso tra San Michele Mondovì e Lesegno. L’area è servita da una strada privata, presente in mappa catastale, che da accesso ai fondi coltivati e permettere di raggiungere l’area della traversa in sponda destra orografica. L’accesso esistente della suddetta pista sulla S.S. 28 è sufficientemente largo e ottimale anche per mezzi d’opera. La pista, nella parte terminale, presenta una pendenza variabile ed una larghezza di circe 2,5 metri. Tale tratto, al fine di permettere l’accesso ai mezzi d’opera (autocarri e autogrù) dovrà essere oggetto di interventi di sistemazione che consisteranno nell’allargamento in corrispondenza delle curve e nella regolarizzazione del fondo. Tali interventi non comportano particolari problematiche o la realizzazione di opere di contenimento rilevanti. Il cantiere nel suo complesso sarà di tipo puntuale è potrà essere così suddiviso: Opere in alveo: relativo alla traversa, comporterà la realizzazione di rilevati temporanei in terreno sciolto Impianto idroelettrico: relativo all’impianto in sponda destra, comporterà la realizzazione scavi in marna. La natura della stessa dovrà essere accertata al fine di definire eventuali opere provvisionali di contenimento Locale quadri/ENEL: relativo al fabbricato fuori-terra, comporterà la realizzazione di un breve tratto di nuova pista, circa 25 metri. Elettrodotto: relativo alla linea MT, definito da ENEL Distribuzione spa inizialmente interessa la pista esistente quindi ricalca parzialmente una linea dismessa sino ad una cabina lungo la S.S. 28. La realizzazione delle opere, anche data eterogeneità delle lavorazioni previste (movimenti terra, carpenteria edile, impiantistica specializzata e non, ecc), potrà essere realizzata da varie squadre di lavoro operanti contemporaneamente nelle varie aree del cantiere. In questo modo è possibile ridurre in maniera significativa i tempi di cantiere e quindi l’impatto visivo che lo stesso cantiere può generare, senza però influire sull’aspetto legato alla sicurezza dei lavoratori. La pianificazione temporale degli interventi, data la natura delle opere, è subordinata alle condizioni idrauliche del Torrente Corsaglia ponendo contestualmente quale prioritaria la tutela della derivazione irrigua per la quale potranno essere realizzate opere avente carattere provvisorio (es. tubazioni). Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 97 Relazione tecnica 21. ATTESTAZIONE DI CREDITO Il proponente, allega copia fotostatica dell'attestazione di credito, come da richiesta del Regolamento Regionale 10/R del Piemonte. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 98 Relazione tecnica 22. VERIFICHE IDRAULICHE DEL TORRENTE CORSAGLIA Il Regolamento Regionale 10/R del 29 luglio 2003 della Regione Piemonte richiede la determinazione dei profili della corrente relativi agli stati di magra, ordinario e di massima piena con tempo di ritorno di 100 anni. L’analisi della compatibilità idraulica degli interventi in progetto è svolta con la verifica idraulica del corso d’acqua con la portata di massima piena definita col tempo di ritorno di 200 anni. Le verifiche idrauliche del torrente Corsaglia presso le opere di presa e restituzione, considerano tutte le situazioni precedentemente elencate, sono contenute nell'elaborato progettuale 22 “Compatibilità con il PAI”, secondo la seguente organizzazione: ... 5. Verifiche idrauliche del Torrente Corsaglia 5.1. Portate di calcolo 5.2. Verifica idraulica del torrente Corsaglia 5.2.1. Metodo di calcolo numerico 5.2.2. Modello idraulico 5.2.3. Risultati della situazione di rilievo 5.2.4. Risultati della situazione di progetto 5.2.5. Analisi dei risultati 23 23 24 24 25 26 30 34 ... 7. 8. Profili e sezioni delle verifiche idrauliche 61 7.1. Situazione di rilievo 7.1.1. Portata di massima piena duecentennale 7.1.2. Portata di massima piena centennale 7.1.3. Portata media annua 7.1.4. Portata di magra 61 61 70 79 88 7.2. Situazione di progetto 7.2.1. Portata di massima piena duecentennale 7.2.2. Portata di massima piena centennale 7.2.3. Portata media annua 7.2.4. Portata di magra 97 97 107 117 127 Planimetria delle aree esondabili 137 Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 99 Relazione tecnica 23. ANALISI DEL TRASPORTO SOLIDO Di seguito si definisce la dimensione minima stabile del materiale che costituisce il fondo alveo nelle sezioni oggetto della verifica idraulica del torrente Corsaglia presso l'impianto idroelettrico in progetto. 23.1. Metodo di calcolo Per il calcolo si è applicata la teoria del moto incipiente di Shields. Il movimento del materiale di fondo non coesivo avviene quando la coppia di valori adimensionali ψ= γ ⋅ R ⋅i (γ s − γ ) ⋅ d Re * = g ⋅ R ⋅i ⋅ d ⋅ ρ η supera la curva di Shields. Le grandezze citate hanno il seguente significato: peso specifico dell’acqua; γ = 9810 N/m3 γs = 25506 N/m3 peso specifico del materiale di fondo; R raggio idraulico; i pendenza del fondo dell’alveo; d diametro del materiale di fondo; g = 9,81 m/s2 accelerazione di gravità; ρ = 1000 kg/m3 densità dell’acqua; η = 0,001370 Pa s viscosità dell’acqua. Di seguito si riportano i risultati ottenuti nelle sezioni considerate. I grafici riportano oltre alla curva di Shields, anche i punti corrispondenti ai diametri minimi stabili nelle sezioni analizzate. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 100 Relazione tecnica 23.2. Portata di massima piena centennale Tabella 28: Diametri minimi stabili Sezione Sezione 1 Sezione 2 Sezione 3 Sezione 4 Sezione 5 Sezione 6 Sezione 7 Sezione 8 Sezione 9 Sezione 10 Sezione 11 Sezione 12 Sezione 13 Sezione 14 Sezione 15 i 0,17% 0,17% 0,28% 0,43% 0,73% 0,43% 0,10% 0,23% 0,59% 0,14% 0,04% 0,04% 0,18% 0,69% 0,96% Esistente R (m) d (m) 2,67 0,048 2,98 0,053 2,57 0,077 1,87 0,087 2,07 0,162 1,89 0,088 2,45 0,025 2,04 0,050 1,66 0,105 1,92 0,029 2,65 0,013 2,76 0,011 2,23 0,043 2,01 0,149 1,58 0,163 Re* 7348 8494 14934 17894 45293 18308 2775 7851 23684 3353 981 765 6213 39871 45791 i 0,17% 0,17% 0,28% 0,43% 0,73% 0,43% 0,10% 0,23% 0,59% 0,07% 0,01% 0,01% 0,15% 0,69% 0,96% Progetto R (m) d (m) 2,67 0,048 2,98 0,053 2,57 0,077 1,87 0,087 2,07 0,162 1,89 0,088 2,45 0,025 2,04 0,050 1,66 0,105 2,61 0,019 3,6 0,006 3,7 0,005 2,31 0,037 2,01 0,149 1,58 0,163 Re* 7342 8494 14934 17894 45293 18321 2775 7861 23642 1753 315 245 4925 39871 45791 Grafico 8: Curva di Shields Si riscontrano variazioni nel diametro minimo stabile solamente tra le sezioni 10 e 13, tuttavia la differenza è irrisoria rispetto alla dimensione dei ciottoli spostati dalla corrente. Inoltre tra le sezioni 10 e 12, nella situazione di progetto, l'alveo è formato da strutture amovibili, pertanto il trasporto solido non riguarda il fondo, bensì solamente il materiale trasportato in superficie. In conclusione le differenze nel trasporto solido sono limitate sia nel diametro minimo stabile sia nell’area d’influenza e non si prevedono cambiamenti apprezzabili nell’equilibrio dell’alveo del torrente Corsaglia. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 101 Relazione tecnica 23.3. Portata media annua Tabella 29: Diametri minimi stabili Sezione Sezione 1 Sezione 2 Sezione 3 Sezione 4 Sezione 5 Sezione 6 Sezione 7 Sezione 8 Sezione 9 Sezione 10 Sezione 11 Sezione 12 Sezione 13 Sezione 14 Sezione 15 i 0,29% 0,25% 0,27% 0,35% 0,44% 0,61% 0,10% 0,09% 0,21% 2,24% 0,17% 0,51% 0,33% 1,71% Esistente R (m) d (m) 0,33 0,010 0,36 0,010 0,39 0,012 0,35 0,013 0,3 0,014 0,38 0,025 0,39 0,005 0,42 0,004 0,35 0,008 0,12 0,24 0,37 0,4 0,26 0,029 0,005 0,020 0,014 0,048 Re* 732 674 861 1072 1191 2760 219 188 511 3431 220 2028 1205 7335 i 0,27% 0,31% 0,12% 0,02% 0,00% 0,08% 0,33% 1,73% Progetto R (m) d (m) 0,33 0,010 0,33 0,011 0,48 0,007 0,73 0,002 1,1 0,001 0,66 0,4 0,26 Re* 663 817 368 71 14 0,006 0,014 0,048 291 1206 7434 Grafico 9: Curva di Shields Dall'analisi sono escluse alcune sezioni, poiché in esse il valore dei parametri adimensionali della curva di Shields è esce dall'intervallo di valori noti. Dall’analisi emerge che la traversa influenza il trasporto solido nel tratto verso monte fino alla sezione 3 inclusa. Nell'area di influenza il diametro minimo stabile è generalmente minore, quindi il torrente tenderà a sedimentare. Tuttavia l'analisi in condizioni di piena evidenzia come con portate maggiori il trasporto solido è ripristinato, così gli eventuali accumuli sono trasportati verso valle senza difficoltà. A valle il diametro minimo stabile subisce una lieve variazione solamente nella sezione 13. Studio di ingegneria CAPELLINO Antonio – Via Rosa Bianca 18 – Mondovì (CN) 102