1 2 3 4 5 6 7 8 9 10 11 12 L1(R) L2(S) L3(T) A A N PE -PE L1 L2 L3 B C B -FT1 L1 L2 L3 L5 L4 0 -TR1 -FT2 110 24 C 9 9 400 415 2.1 0 PE D -QIM 1 3 D 5 6,3-10 A. E E I>> I>> I>> 2 4 6 L11 F F L10 L9 G G -K2M 1 3 5 2 4 6 -K1M 3 5 2 4 2.8 6 2.7 H -K3M 1 3 5 2 4 6 2.7 H U1 V1 W1 I 1 W2 U2 V2 U1 V1 W1 I W2 U2 V2 11 11 2.1 PE J W1 M V1 U1 3 J V2 U2 W2 K K -M1 MOTORE SPIRALE L L CLIENTE: LOCALITA': DESCRIZIONE: C.P. spa via Perotti, 5 25125 BS- ITALY AVV.CPM ART: 60 - MANUALE 400V - 50HZ DATA: 28/04/04 DIS.: CA PROGETTO: CP--305073B--001.PRG 1 2 3 REV. 4 5 6 7 8 DATA: 19/01/2012 FIRMA: 9 10 11 FG.: 1 DI 6 12 1 9 2 3 4 5 6 7 8 9 10 11 12 9 1.12 2 A -KA1 -KA1 12 4 9 9 3.1 2 3.1 A 2 1 -SQ1 B -K1M 53 B 1 54 7 C -SB1 D -KA2 12 -KA2 12 4 -SB3 6 3 -K1M 63 2 F D -KT1 8 8 E C 10 7 E 31 -SB2 -SA1 F 8 64 4 G 4 G 8 -K2M 21 H -SA1 -K1M A1 19 -HL1 H 72 17 J -K1M 71 4 22 I -SA1 20 8 I 18 -KT1 7 -KT2 7 -K2M A1 -K3M A1 2 2 A2 A2 A2 8 -HL2 J -KA2 A1 A2 K K 11 11 1.12 11 L 3.1 L CLIENTE: LOCALITA': DESCRIZIONE: C.P. spa via Perotti, 5 25125 BS- ITALY AVV.CPM ART: 60 - MANUALE 400V - 50HZ DATA: 28/04/04 DIS.: CA PROGETTO: CP--305073B--001.PRG 1 2 3 REV. 4 5 6 7 8 DATA: 19/01/2012 FIRMA: 9 10 11 FG.: 2 DI 6 12 1 A 9 2.12 2 2.12 2 3 4 5 6 7 8 9 10 11 12 9 A 2 -SA1 B B 16 -SB2 C C 15 D D -SB3 E E 14 -KT1 1 F -SB2 -KT2 1 -KA2 9 -KT2 8 3 5 6 3 F G G 5 H 13 H 6 -K1M 61 62 I I 12 J -KT1 4 -KT2 4 2 2 -HL3 J -KA1 A1 A2 K K 11 2.12 11 L L CLIENTE: LOCALITA': DESCRIZIONE: C.P. spa via Perotti, 5 25125 BS- ITALY AVV.CPM ART: 60 - MANUALE 400V - 50HZ DATA: 28/04/04 DIS.: CA PROGETTO: CP--305073B--001.PRG 1 2 3 REV. 4 5 6 7 8 DATA: 19/01/2012 FIRMA: 9 10 11 FG.: 3 DI 6 12 1 2 3 4 5 6 7 8 9 10 SB2 A FT1 FT2 12 SB3 A SB1 KT1 Q1M B 11 KT2 STOP TR1 B EMERGENCY C C I SA1 0 D D TEST E W2 PE 2 7 E F U2 V2 F K1M K2M K3M W1 K2A V1 K1A G L2 L3 PE U1 G H PE L1 H PE L1 L2 L3 PE U1 V1 W1 U2 V2 W2 PE 2 7 I I J LINEA ALIMENTAZIONE 3x400 V. / 50 HZ MOTORE SPIRALE M1 J SQ1 MICRO SICUREZZA K K L L CLIENTE: LOCALITA': DESCRIZIONE: C.P. spa via Perotti, 5 25125 BS- ITALY AVV.CPM ART: 60 - MANUALE 400V - 50HZ DATA: 28/04/04 DIS.: CA PROGETTO: CP--305073B--001.PRG 1 2 3 REV. 4 5 6 7 8 DATA: 19/01/2012 FIRMA: 9 10 11 FG.: 4 DI 6 12 1 2 3 CODICE 4 5 6 7 DESCRIZIONE 8 9 10 COSTRUTTORE 11 12 TIPO A B C D E F G H I J K A -Q1M SALVAMOTORE MAGNETOTERMICO MOELLER PKZM010 6.3-10 A. -K1M MINICONTATTORE MOELLER DILEM-01 110 V 50/60 HZ -K2M MINICONTATTORE MOELLER DILEM-01 110 V 50/60 HZ -K3M MINICONTATTORE MOELLER DILEM-01 110 V 50/60 HZ -K1M BLOCCHETTO AUX FRONTALE MOELLER 22 DILE -KA1 RELE' AUSILIARIO OMRON MY4 110/120 VAC -KA2 RELE' AUSILIARIO OMRON MY4 110/120 VAC -KA1 ZOCCOLO PER RELE' AUSILIARIO OMRON PYF14A-N -KA2 ZOCCOLO PER RELE' AUSILIARIO OMRON PYF14A-N -FT1 PORTAFUSIBILE BIPOLARE SEZIONABILE ELETTROITALIA 2x10x38 -FT1 FUSIBILE 10x38 ELETTROITALIA 1 A. AM -FT2 PORTAFUSIBILE UNIPOLARE SEZIONABILE ELETTROITALIA 1 A. GL -FT2 FUSIBILE 10x38 ELETTROITALIA 1 A. GL -TR1 TRASFORMATORE MONOFASE NORSE 50 VA 0-230-400-415/0-110 COD: 2020571 -X1 MORSETTI POTENZA WEIDMULLER WDU/4 -X1 MORSETTI PE WEIDMULLER WPE/4 -X1 MORSETTI TERMINALI WEIDMULLER EW/35 -A1 CASSETTA STAGNA GEWISS GW44219 + PIASTRA 44617 -KT1 TEMPORIZZATORE CICLO I CDC TY91-602A-B3-115 V -KT2 TEMPORIZZATORE CICLO II CDC TY91-602A-B3-115 V -KT1 ZOCCOLO PER TEMPORIZZATORE CICLO I CDC AZ 58 -KT2 ZOCCOLO PER TEMPORIZZATORE CICLO II CDC AZ 58 -SB1 PULSANTE FUNGO EMERGENZA MOELLER M22-PV -SB2 PULSANTE VELOCITA' I MOELLER M22-DL-X + M22-XDL-W-X1 -SB3 PULSANTE VELOCITA' II MOELLER M22-DL-X + M22-XDL-W-X2 B C D E F G H I J K L L CLIENTE: LOCALITA': DESCRIZIONE: C.P. spa via Perotti, 5 25125 BS- ITALY AVV.CPM ART: 60 - MANUALE 400V - 50HZ DATA: 28/04/04 DIS.: CA PROGETTO: CP--305073B--001.PRG 1 2 3 REV. 4 5 6 7 8 DATA: 19/01/2012 FIRMA: 9 10 11 FG.: 5 DI 6 12 1 2 3 CODICE 4 5 6 DESCRIZIONE 7 8 9 10 COSTRUTTORE 11 12 TIPO A A -SA1 SELETTORE MAN-AUT LUMINOSO -SA1/SB1/SB2/SB3 B BASE DI FISSAGGIO PULSANTERIA -SB2 PULSANTE VELOCITA' I -SB3 C PULSANTE VELOCITA' II -SB2-SB3 PROTEZIONE IP67 PER PULSANTE -SB2-SB3-SA1 D LED LUMINOSO BIANCO -SB1/SB2/SB3 CONTATTO CHIUSO -SA1/SB2/SB3 CONTATTO APERTO MOELLER M22-WRLK-W MOELLER M22-A MOELLER M22-DL-X + M22-XDL-W-X1 MOELLER M22-DL-X + M22-XDL-W-X2 MOELLER M22-T-D MOELLER M22-LED230-W MOELLER M22-K01 MOELLER M22-K10 B C D E E F F G G H H I I J J K K L L CLIENTE: LOCALITA': DESCRIZIONE: C.P. spa via Perotti, 5 25125 BS- ITALY AVV.CPM ART: 60 - MANUALE 400V - 50HZ DATA: 28/04/04 DIS.: CA PROGETTO: CP--305073B--001.PRG 1 2 3 REV. 4 5 6 7 8 DATA: 19/01/2012 FIRMA: 9 10 11 FG.: 6 DI 6 12