SPECIFICA CONNESSIONI IN SITO - ON SITE CONNECTION DETAILS 1. ELETTRICA - ELECTRICAL Tipo - Type: STANDARD Tensione - Voltage: 400V / 3~+N+PE / 50Hz Potenza - Power: 6,05 kW / 14 A Fusibili - Fuse rating: 3 x 16 A Cavo e sezione min. - Cable and min. section: Colori dei cavi - Cable colours: L1: Nero - Black L2: Grigio - Gray L3: Marrone - Brown N: Blu - Blue PE: Giallo/Verde - Yellow/Green 2. ACQUA DI ALIMENTO - FEED WATER Connessione - Connection: Portata max. - Max. flow rate: Pressione dinamica min. - Min. flow pressure: Pressione max. - Max. pressure: Temperatura max. - Max. temperature: Durezza max. - Max. hardness: 3/4" maschio-male - DN20 25 lt/min 200 kPa (2,0 bar g) 300 kPa (3,0 bar g) n.a. / 5...8 pH 40 mg/l Residuo solido max. - Max. TDS Contamin. max.-Max. pollution grade 3. ARIA COMPRESSADI PROCESSO- COMPRESSED AIR PROCESS Connessione - Connection: 1/8" maschio-male Portata max. - Peak flow rate: Pressione - Supply pressure: 200...800 kPa (2..8 bar g) Contaminazione max. - Max. pollution Olio residuo max. - Max. rest oil Vapore acquo max.- Max. water vapour 67 ppm Temp. rugiada max. - Max. dewpoint temperat. 4. ARIA COMPRESSA TECNICA- TECHNICAL COMPRESSED AIR 1/4" maschio-male Connessione - Connection: Portata max. - Peak flow rate: Pressione -Supply pressure: 600...800 kPa (6..8 bar g) 5. SCARICO PRINCIPALE - MAIN DRAIN Connessione - Connection: Portata max. - Peak flow rate: Altezza max. - Max. height: Temperatura max. - Max. temperature: 6. SFIATO CAMERA - EXHAUST AIR Connessione - Connection: Portata max. - Peak flow rate: Pressione - Pressure: 1"-1/2 - DN40 25 lt/min 0,6 m 0...700 Pa (0...7 mbar g) 7. INGRESSO PER VALIDAZIONE - VALIDATION PORT Connessione - Connection: 1/2" maschio-male DN15 Diametro ingresso - Inlet diameter ALTRE SPECIFICHE - OTHERS DETAILS AMBIENTE - ENVIRONMENT < 40 dB (A) EMISSIONI DI CALORE - HEAT EMISSIONS Max. nel locale-Max. in the room: Max. dal vano tecnico-Max. in service room: Max. dal cesto/oggetti-Max. from trolley/items: PESI - WEIGHTS Netto totale - Total Net: Lordo totale - Total Gross: Max all'uso - Max. on working: Carico a pavimento - Floor load: di acqua potabile, il sistema di drenaggio deve essere collegato mediante un adeguato dispositivo di non ritorno. - Tutte le connessioni dei servizi per la macchina devono rispettare tutte le normative e pratiche locali applicabili. - Il fabbricante si riserva il diritto di apportare modifiche al prodotto che possono non essere riportate nel disegno. - The machine shall be horizontally levelled. - The electrical supply of each machine must be protected with a ground fault interrupter (30 mA, "AC" type). - Manual shut off valves are required adjacent to supply connection points for all media. - For all ducted exhausts prevent condensate backflow into the machine. Pitch vent ducting and discharge condensate at lowest point. - If a steam condenser is supplied and connected to a potable water supply, the machine should be connected to the drainage system using a proper non-return device. - All services connections to the machine must comply with all applicable local codes and practices. - The manufacturer reserves the right to make product changes that may not be reported in the drawing. 252 daN (kg) 270 daN (kg) 310 daN (kg) CONFIGURAZIONE - CONFIGURATION A) Risc. in circolazione-Circulating heating type: E: ELETTRICO-ELECTRICAL B) Risc. in asciugatura-Air drying heating type: X:N.A. C) Risc. in taniche-Tanks water heating type: X: N.A. NOTE - NOTES - La macchina deve essere livellata orizzontalmente. - L'alimentazione elettrica di ogni macchina deve essere protetta con un interruttore differenziale (30 mA, tipo "AC"). - Sono richiesti dei rubinetti/valvole manuali adiacenti alle connessioni per tutti i fluidi. - Per tutti gli scarichi canalizzati si deve prevenire il riflusso di condensa nella macchina. Posizionare i condotti di sfiato e 280 W (240 kcal/h) n.a. 400 W (345 kcal/h) ACCESSORI INSTALLATI - INSTALLED OPTIONALS NESSUNO - NONE 24 25-06-2014 Rev. Data / Date AGGIORNATI DATI ARIA COMPRESSA E SCARICO - DRAIN AND COPRESSED AIR UPDATE Descrizione / Description GA_A3_IT-EN Rev_03 Descrizione/Description: Dis./Drawn: Approv.: PIANTA DI INSTALLAZIONE / INSTALLATION PLANT Modello / Model: Il presente documento di proprieta' della STEELCO spa, esso costituisce un bene di rilevante valore economico e non puo' essere trasmesso e comunque divulgato a terzi senza specifica autorizzazione scritta della Direzione STEELCO. This document is the property of STEELCO spa, it is an asset of considerable economic value and can not be transmitted and otherwise divulged to third perties without specific written permission of the Directorate STEELCO. Franzato S. Capovilla I. Revisione / Revision: Data / Date: Scala / Scale: EW 2/1 (6,05kW 400V 50Hz - EXX version) Codice cliente / Customer code: -- Progetto / Project: STANDARD Ingegneria / Engineering: STEELCO 24 25-06-2014 Rif. ordine / Order ref.: -- -- 1:25