Power Applications Lab DIEET i&pdivision industrial & power conversion A novel linear-non-linear digital control for DC/DC converters DIEET – Università di Palermo Ing. Valeria BOSCAINO Ing. Giuseppe Maria DI BLASI Ing. Patrizia LIVRERI Prof. Ing. Giuseppe CAPPONI http://www.dieet.unipa.it/labep [email protected] Riunione Annuale GE 2006 I&PC Division – STMicroelectronics Ing. Filippo MARINO Ing. Marco MINIERI Ischia, 21-23 giugno 2006 Main features Multiphase system Digital control PWM control technique Voltage-Positioning (AVP) Riunione Annuale GE 2006 Ischia, 21-23 giugno 2006 Four module interleaved buck converter Input Voltage: 12V Output Voltage: 1V Output Current: 0-120A Maximum Output Voltage Ripple 30mV during transient 2mV at steady state Switching frequency 250kHz/phase Riunione Annuale GE 2006 Ischia, 21-23 giugno 2006 Single phase linear control loop Current-sharing comparator Riunione Annuale GE 2006 Adaptive voltage positioning Ischia, 21-23 giugno 2006 VREF VOUT 4 Q4 Q3 Q2 Q1 4 ADC Switching Logic Phase 1 PWM1 VC1,i VC2,1 CS1 DAC PWM2 VC1,1 VC2,2 CS2 DAC PWM3 Switching Logic Phase 3 VC1,2 VC2,3 CS3 DAC PWM4 VC1,3 VC2,4 Switching logic DAC according to interleaved technique Riunione Annuale GE 2006 COMP_OUT VC2,i Switching Logic Phase 2 Switching Logic Phase 4 AVP ADC 4 4-module step-down converter VDC COMP CS4 VC1,4 Ischia, 21-23 giugno 2006 Non linear control: items Fast transient response to load changes No over- and under-shoots in regulated output voltage during transient Riunione Annuale GE 2006 Ischia, 21-23 giugno 2006 Non linear control Vin=12V MULTIPHASE DC/DC CONVERTER OUTPUT VOLTAGE NON LINEAR CONTROL LINEAR CONTROL Riunione Annuale GE 2006 Ischia, 21-23 giugno 2006 Non linear control action Increasing load current Riunione Annuale GE 2006 Decreasing load current Ischia, 21-23 giugno 2006 Non linear control: main advantages Recovery time reduction by 25% up to 40%. Output voltage over- and under- shoots reduction by 50% up to 65%. Non linear control active only during a load transient Unaffected steady-state operation. Unchanged converter topology. Possible applications on any dc/dc converter topology . AVP compatible. System bandwidth independent from that of the linear control loop. Solved limit-cycle problems. Non linear action dependent only on output voltage. Easy implementation. Riunione Annuale GE 2006 Ischia, 21-23 giugno 2006