Silicon strip detectors for two-dimensional soft x-ray imaging at normal incidence Pedro Rato Mendes LIP Lisbon and University of Algarve, Portugal Amsterdam, 09-12 September 2002 Outline • Collaboration members • Objectives • Experimental setup • Energy calibration • Imaging results • Conclusions and future work Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Collaboration members M. C. Abreu a, G. Baldazzi b, D. Bollini b, E. Cabal Rodriguez c, W. Dabrowski d, A. Diaz Garcia c, M. Gambaccini e, P. Giubellino f, M. Gombia b, P. Grybos d, M. Idzik d,f, A. Marzari-Chiesa g, L. M. Montano h, F. Prino i, L. Ramello i, P. Rato Mendes a, S. Rodrigues a, M. Sitta i, P. Sousa a, K. Swientek d, A. Taibi e, A. Tuffanelli e, R. Wheadon f, P. Wiacek d a b LIP and University of Algarve, Faro, Portugal Dipartimento di Fisica dell’Università di Bologna and INFN, Bologna, Italy c d CEADEN, Havana, Cuba Faculty of Physics and Nuclear Techniques, Academy of Mining and Metallurgy, Cracow, Poland e Dipartimento di Fisica dell’Università di Ferrara and INFN, Ferrara, Italy f g Dipartimento di Fisica Sperimentale dell’Università di Torino and INFN, Torino, Italy h i INFN , Torino, Italy CINVESTAV, Mexico City, Mexico Dipartimento di Scienze e Tecnologie Avanzate dell’Università del Piemonte Orientale and INFN , Alessandria, Italy Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Objectives Develop a simple prototype system for 2-D soft x-ray imaging using silicon strip detectors • Motivations for this prototype – spin-off from high-energy physics – RX64 chip designed for this application – simple laboratory setup and data-acquisition – advanced education for young physicists RX64 and its main applications: talk by L. Ramello, this conference W. Dabrowski et al., RX64 – A Fully Integrated 64-channel IC for Readout of Silicon Detectors Used for X-Ray Position Sensitive Measurements, IEEE NSS/MIC 2001, San Diego Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Experimental setup • Equipment – board with 1-sided microstrip detectors and RX64 chips • 300 m thick Si, 132 strips at 100 m pitch (ITC-IRST, Trento, Italy) • RX64 chip by W. Dabrowski and collaborators (Cracow, Poland) • one or two chips per board (64 or 128 channels) – – – – PC with NI PCI-DIO-96 interface + LabVIEW 6i software scanning system controlled by stepper motor radiation sources (57Co, 109Cd, 241Am for fluorescence) power supplies, cables • Two-dimensional image acquisition – acquire 1-D profiles for each collimator position – form 2-D image by juxtaposition of 1-D profiles Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Experimental setup silicon microstrip detector PC National Instruments 64 PCI-DIO-96 LabVIEW 6i RX64 - 64 channels (preamp, shaper, discriminator) - 64 pseudo-random counters (20-bit) - internal calibration circuit (1 mV to 30 mV) - I/O on chip (interface with external bus) Pedro Rato Mendes et al. RX64 IWoRID’2002 - Amsterdam First test board (one RX64 chip) 0.6 1.0 cm2 detector RX64 Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Energy calibration • Method – perform discriminator threshold scan – differentiate integral spectrum – fit energy peaks on differential spectrum integral spectrum Pedro Rato Mendes et al. differential spectrum IWoRID’2002 - Amsterdam Energy calibration Calibration using Co57 and Cd109 sources (board with one RX64 chip, average on all channels) Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Energy calibration Calibration using Am241 x-ray fluorescence source (board with two RX64 chips, average on all channels) Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Scanning system stepper motor scanning radioactive source Pb collimator detector board Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Imaging results – one RX64 chip 300 kBq 109Cd source – 22 keV Ag K x-rays 15 mm thick Pb collimator, 300 µm wide slit Pb 0.5 mm thick scanning system microstrip detector 1.0 1.0 mm2 Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam Imaging results – two RX64 chips 300 kBq 109Cd source – 22 keV Ag K x-rays 15 mm thick Pb collimator, 300 µm wide slit HIGH CONTRAST 8-pin integrated circuit Pedro Rato Mendes et al. 1.0 1.0 mm2 LOW CONTRAST snail shell IWoRID’2002 - Amsterdam Conclusions We have built and tested a simple prototype for 2-D soft x-ray imaging • Prototype main features – one-sided silicon microstrip detectors – simple readout electronics based on RX64 chip – simple 2-D scanning system • Future developments – larger area sensors / more readout chips – new chip version with two thresholds – x-ray tube as radiation source Pedro Rato Mendes et al. IWoRID’2002 - Amsterdam