M.G. Pellegriti Laboratori Nazionali del Sud – INFN Dipartimento di Fisica ed Astronomia, Università di Catania Alpha Stucture of 12B Studied by Elastic Scattering of 8Li Excyt Beam on 4He Thick Target 10th International Spring Seminar on Nuclear Physics Vietri sul Mare, 21-25 May 2010 Outlook Search for 8Li+a cluster state in 12B 1) 12B states: experiment and theory 2) Experimental method: 8Li+a12B*8Li+a Inverse Kinematic Resonant Elastic Scattering on Thick Target Problems: superposition of elastic and inelastic scattering Time measurement 3) The Set-up at LNS: 8Li beam from EXCYT, CT2000 chamber filled with 4He gas 4) Preliminary results 5) Conclusions Exotic Clustering Clustering in neutron rich nuclei: description of unstable nuclei as di-nuclear structures Matter density distribution in Boron isotopes ground states (AMD calculations): drastic changes in the isotopes structure with the increasing number of neutrons α – 7Li structure spherical structure, single particle prolate di-nuclear structure Y. Kanada-En’yo and H. Horiuchi PRC 52 (1995) 647 12B states Investigation of the 8Li-alpha system allows the observation of 12B states above the decay threshold 10 MeV 8Li GCM prediction of 8Li-alpha structures indicates the presence of two rotational bands of opposite parity +α P. Descouvemont, NPA 596 (1996) 285 8Li+a12B*8Li+a Thick Target Inverse Kinematic (TTIK) Resonant Elastic Scattering 8Li+a12B*8Li+a Pictorial view E-DE K. P. Artemov et al. Sov. J. Nucl. Phys. 52, 408(1990) target inverse kinematics forward focused recoil alphas Ebeam-DEb1 Ebeam-DEb2 qlab qlab Ebeam Ea2-DEa1 beam energy loss in the target wide range for Ecm alpha spectra information on the resonance parameter by using R-matrix analysis Ea1-DEa1 ds/dW Interference effects are reflected in the spectrum shape Ecm2 Ecm1 Ecm IMPORTANT INGREDIENTS: energy loss for beam and recoil in the target Time measurement for the discrimination of elastic from inelastic events for infinite thick target E-DE target Ebeam-DE1 a a qlab 8Li+a same energy time Ebeam-DE2 qlab inelastic Ebeam elastic Ea-DEa Ea-DEa Problem: Ea-DEa=Ea-DEa !!!! 12B elastic inelastic inelastic elastic Dt is important ! start E time stop Experimental Set-up T=300 °K P= 700 mbar 4He Eb=30.6MeV 5 ·104pps EXCYT gas 1 a Kapton foil 8Li 2 3 MCP foil Si DE-E’s qlab=0° a beam direction DE3 E3 4 DE(MeV) Preliminary Results qlab=0° telescope a Time (ns) t p E(MeV) inelastic a’s 3.21 MeV, 3+ 2.25 MeV, 1+ 0.98 MeV, 2+ tritons elastic a’s simulation punch-through DE detector Thickness:47mm Resolution: 150 keV Time resolution <1 ns DE(MeV) ds/dW(mb/sr) Elastic cross section for Ecm<5MeV Ecm(MeV) Conclusions 8Li+4He8Li+a has been studied from E=30.6 MeV down to zero The TTIK experimental technique with the time measurement improvement allows discrimination between elastic and inelastic (or other) scattering 8Li-alpha elastic scattering cross section has been obtained around qcm= 180° (qlab=0°) Evidence for large resonances in the elastic scattering spectra has been observed for Ecm<5MeV FUTURE ANALYSIS: Montecarlo Simulation including: beam profile (experimental collimation) energy and angular straggling for beam and recoil particles Error bars estimation Data analysis with Ecm>5MeV (zone with DE-E identification) R-matrix analysis to obtain the resonance parameters Collaboration M.G. Pellegritia,b, D.Torresia,b, L. Cosentinoa, A. Di Pietroa, C. Ducoinc, M. Lattuadaa,b, T. Lonnrothd, P. Figueraa, M. Fisichellaa, C. Maiolinoa, A. Musumarraa,e, M. Papad, M. Rovitusob, V. Scuderia,a,f, G. Scaliaa,b, D. Santonocitoa, M. Zadrog a) INFN Laboratori Nazionali del Sud, Catania, Italy b) Dipartimento di Fisica ed Astronomia, Università di Catania, Catania, Italy c) INFN, Sezione di Catania, Italy d) Åbo Academy, Turku, Finland e) Dipartimento di Metodologie Fisiche e Chimiche per l’Ingegneria, Università di Catania, Catania, Italy f) CSFNSM, Catania, Italy g) Ruđer Boskovic Institute, Zagreb, Croatia Time measurement Microchannel Plate EXCYT How to extract the resonance parameters from the experimental data: The R-matrix formalism A.N. Lane and R.G. Thomas, Rev. Mod. Phys. 30 (1958) 257-353. The R-matrix R(E) The differential cross section The collision matrix Ul The phase shift dl With the R-matrix for l poles defined as: Pole parameters (calculated or formal) Resonance parameters (observed or experimental) are related to 8Li 12B