va
ila
a
LOWNO x
re
q u e st
E
flam
co
ble o n
m
Ecofla
BLU
GAS BURNERS
BRUCIATORI DI GAS
Ecoflam was founded in 1973 in Castelfranco Veneto,
near Venice in the North East of Italy.
For more than thirty years Ecoflam has continued to
develop all its products with constant dedication and
determination addressing Technological Research,
Ecology, Energy Saving, and Safety.
Ecoflam today offers a full range of blown air pressure
jet burners designed and tested in our “GREEN”
modern laboratories. All products conform to CE
standards and are manufactured in accordance with
ISO 9001 and VISION 2000 certification.
Ecoflam burners guarantee high efficiency and
reliable operation with significant energy savings. All
models feature extreme ease of installation
maintenance and flexible boiler - burner matching.
Ecoflam nasce nel 1973 a Castelfranco Veneto,
vicino a Venezia, nel cuore del Nord Est dell‘Italia.
Da oltre trenta anni Ecoflam ha continuato a
sviluppare tutti i prodotti con costante dedizione e
determinazione rivolgendo particolare attenzione
alla ricerca tecnologica, all’ecologia, al risparmio
energetico e alla sicurezza.
Ecoflam oggi è in grado di offrire una gamma completa di bruciatori ad aria soffiata completamente
progettati e sviluppati nei moderni laboratori della
divisione GREEN (Gruppo Ricerca Ecoflam Energia).
Tutti i prodotti sono soggetti a severi controlli e collaudi, rispettano le norme CE e sono certificati ISO 9001
e VISION 2000.
I bruciatori Ecoflam garantiscono un’alta efficienza e
affidabilità di funzionamento unito a un notevole
risparmio energetico. Tutti i modelli si caratterizzano
per un’estrema facilità di installazione e manutenzione e flessibilità di accoppiamento con qualsiasi tipo
di generatore.
OPERATION / FUNZIONAMENTO
P
...P AB
...PR
...MD
On-Off Soft Start
HI-LOW with servomotor
Progressive
Modulating
1 regime di fiamma (apertura lenta)
2 regimi di fiamma con servomotore
Progressivo
Modulante
MAIN FEATURES / CARATTERISTICHE
• Aluminium casing up to Blu P 4000.1 and steel
casing from P 5000.1 with electrical panel
integrated on the burner.
• New high efficiency fan ventilator designed to
give flame stability and easy matching.
• Adjustable combustion head for fine tuning /
matching with different shapes of combustion
chamber.
• Low NOx versions available from BLU 500.1 to
1400.1 ( Class 3 < 80mg/kWh, as per EN 676).
BLU 2000.1 PAB
• Hi - Low version with easy and fast butterfly ratio
system available from Blu P 500 to Blu 2000.1.
• Corpo in alluminio fino al Blu 4000.1 e in acciaio
dal Blu 5000.1 con pannello elettrico integrato a
bordo macchina.
• Progressive version with electrical servomotor and
adjustable mechanical cam that allows gas fine
tuning.
• Ventilatore al alta efficienza progettato per
garantire stabilità della fiamma e facile
accoppiamento.
• Modulating version with PID system controller with
digital set point display and real time value (PID
RWF 40 or LMV 51/52 optional ).
• Testa di combustione regolabile per garantire
migliori accoppiamenti sui differenti camere di
combustione.
• Firing head with automatic adjustable system for
primary air that changes according to output
required from Blu P 7000.1.
• Versione Low NOx dal Blu 500.1 al Blu 1400.1 (classe
3 < 80 mg/kWh in base alla norma EN676).
• Easy maintenance of firing head from the burner
top cover.
• On request tailored solutions of flame shape.
• Versione a due fiamme con nuovo sistema a
farfalla di regolazione gas semplice e veloce, dal
Blu 500.1 fino Blu 2000.1.
• Bruciatori progressivi con servomotore ad alta
coppia, e camma a profilo variabile per la
regolazione fine del gas.
• Versioni modulanti con termoregolatore PID con
display digitale che visualizza il valore reale e
permette di regolare il set point.
• Sistema automatico di regolazione dell’aria
primaria che varia in base alla portata richiesta dal
Blu 7000.1.
• Facile manutenzione grazie alla estrazione della
testa di combustione dal retro del bruciatore .
• A richiesta fiamma a geometria variabile.
BLU 3000.1 MD
WORKING FIELDS / CAMPI DI LAVORO
mbar 6
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
5
4
Blu 350 P/PAB
Blu 250 P/PAB
3
2
Blu 170 P/PAB
1
0
50
75
60
80
100
100
120
125
140
150
160
180
175
200
200
220
225
240
260
250
280
275
300
kcal/h
x 1000
300
320
340
360 kW
BURNER OUTPUT / POTENZA
mbar 9
Blu 700 P
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
8
Blu 500 P
7
6
5
4
Blu 1400 P AB
3
Blu 1000 P AB
Blu 700 P AB
Blu 500 P AB
Blu 1200 P AB
2
1
0
200
100
200
300
300
400
400
500
500
600
600
700
700
800
800
900
900
1000
1000
1100
1200
1100
1300
kcal/h
x 1000
kW
BURNER OUTPUT / POTENZA
TECHNICAL DATA / DATI TECNICI
MODELS
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
170
250
350
500
500
700
700
1000
1200
1400
Output
Potenza termica
max.
kW
kcal/hx1000
180
154,8
230
197,8
350
301
500
430
500
430
700
602
700
602
1.000
860
1.200
1.032
1.300
1.118
Output
Gas pressure
Potenza termica
Pressione
min.
gas
kW
kcal/hx1000
mbar
89
76,54
20 ÷ 300
95
81,7
20 ÷ 300
147
126,42
20 ÷ 300
250
215,4
20 ÷ 300
190
163,4
20 ÷ 300
350
301
20 ÷ 300
250
215
20 ÷ 300
300
258
20 ÷ 300
400
344
20 ÷ 300
400
344
20 ÷ 300
Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3)
Power
supply
Tensione
V
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
Motor
Motore
kW
0,25
0,25
0,3
0,55
0,55
0,74
0,74
1,1
2,2
2,2
Operation
Funzionamento
P-P AB
P-P AB
P-P AB
P
P AB
P
P AB
P AB
P AB
P AB
Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3)
WORKING FIELDS / CAMPI DI LAVORO
mbar 9
8
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
7
6
5
4
Blu 1400 PR/MD
3
2
Blu 500 PR/MD
Blu 700 PR/MD
Blu 1000 PR/MD
Blu 1200 PR/MD
1
0
100
100
200
300
200
300
400
400
500
500
600
600
700
700
800
800
900
900
1000
1000
1100
kcal/h
x 1000
1100
1200
kW
1300
BURNER OUTPUT / POTENZA
mbar
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
12
10
8
6
Blu 1700.1
Blu 2000.1
4
2
0
200
200
400
600
600
400
800
800
1000
1000
1200
1200
1400
1400
1600
1600
kcal/h
2000 x 1000
1800
1800
2000
2200
kW
BURNER OUTPUT / POTENZA
TECHNICAL DATA / DATI TECNICI
Output
Potenza termica
max.
kW
kcal/hx1000
Output
Gas pressure
Potenza termica
Pressione
min.
gas
kW
kcal/hx1000
mbar
Power
supply
Tensione
V
Motor
Motore
BLU 500
500
430
120
103,2
20 ÷ 300
230/400
0,55
PR-MD
BLU 700
700
602
190
163,4
20 ÷ 300
230/400
0,74
PR-MD
BLU 1000
1.000
860
200
172
20 ÷ 300
230/400
1,1
PR-MD
BLU 1200
1.200
1.032
180
154,8
20 ÷ 300
230/400
2,2
PR-MD
BLU 1400
1.300
1.118
250
215
20 ÷ 300
230/400
2,2
PR-MD
BLU 1700.1
1.770
1.526
342
295
20 ÷ 300
230/400
3
P AB-PR-MD
BLU 2000.1
2.150
1.853,45
414
356,9
20 ÷ 300
230/400
4
P AB-PR-MD
MODELS
Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3)
Operation
Funzionamento
kW
Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3)
WORKING FIELDS / CAMPI DI LAVORO
mbar 22
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
20
18
Blu 5000.1
16
14
u
Bl
12
60
00
u
Bl
10
.1
40
00
8
.1
Blu 3000.1
6
4
2
0
500
1000
500
1500
1500
1000
2000
2000
2500
2500
3000
3000
3500
3500
4000
4000
4500
4500
5000
kcal/h
x 1000
5000
kW
5500
BURNER OUTPUT / POTENZA
mbar 40
38
36
34
32
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
30
28
26
Blu
Blu 10000.1
12
00
24
0.1
Blu 15000.1
22
20
18
Blu
16
80
00
14
.1
12
10
Blu 7000.1
8
6
4
2
0
1000
1000
2000
2000
3000
3000
4000
4000
5000
5000
6000
6000
7000
7000
8000
8000
9000
9000
10000
10000
11000
11000
12000
13000
12000
14000
13000
15000
14000
16000
15000
17000
kcal/h
x 1000
kW
BURNER OUTPUT / POTENZA
TECHNICAL DATA / DATI TECNICI
MODELS
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
3000.1
4000.1
5000.1
6000.1
7000.1
8000.1
10000.1
12000.1
15000.1
Output
Potenza termica
max.
kW
kcal/hx1000
3.000
2.586
3.900
3.362
5.000
4.310
5.800
5.000
7.250
6.250
8.500
7.327,5
10.500
9.052
13.100
11.293,1
16.800
14.448
Output
Gas pressure
Potenza termica
Pressione
min.
gas
kW
kcal/hx1000
mbar
630
543,1
40 ÷ 300
875
754,3
40 ÷ 300
1.200
1.034,5
40 ÷ 300
1.500
1.290
50 ÷ 500
1.500
1.290
50 ÷ 500
2.000
1.724
100 ÷ 500
2.500
2.155
100 ÷ 500
2.700
2.327,6
150 ÷ 500
3.464
2.986
200 ÷ 500
Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3)
Power
supply
Tensione
V
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
Motor
Motore
kW
5,5
7,5
11
15
15
18,5
22
37
45
Operation
Funzionamento
PR-MD
PR-MD
PR-MD
PR-MD
PR-MD
PR-MD
PR-MD
PR-MD
PR-MD
Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3)
DETAILS / PARTICOLARI
RWF 40 Regulator
Progressive version with servomotor and
adjustable mechanical cam
Regolatore RWF 40
Butterfly valve
Valvola a farfalla
Blu 500÷1400 PAB
Servomotore con camma meccanica per
versione progressiva
Blu 8000.1 MD
LMV51/52 System
Sistema LMV51/52
Modulating version with PID
regulated (proportional, integral and derivative) digital
control board.
Versione Modulante regolatore digitale PID.
Integrated electric panel
Pannello elettrico integrato
Blu 500÷1400 PAB
Diffuser
Diffusore
Blu 500 P AB
Diffuser
Diffusore
Blu 8000.1 PR/MD
LOW NOx
E
re
q u e st
flam
co
va
ila
a
LOWNO x
ble o n
m
Ecofla
• The new range of Ecoflam Low NOx gas burners
is the direct response to the need to reduce
atmospheric pollutants in particular acid rain.
• The new Ecoflam engineered and designed
combustion heads enable the burners to surpass
the most stringent regulations and standards
regarding pollutant emissions, see emission
classification table.
• The new range of Low NOx gas burners are built
to the highest quality and engineering standards
as expected from Ecoflam thus ensuring high
efficiency and reliable operation.
• I nuovi bruciatori Ecoflam Low NOx a basse emissioni
di ossidi azoto rappresentano la soluzione diretta
all’inquinamento atmosferico ed in particolare alle
piogge acide.
• Le nuove teste di combustione progettate nei
laboratori Ecoflam permettono di rispettare a pieno
le normative più restrittive sulle emissioni inquinanti
(vedi tabella classe emissioni).
Combustion head
Testa di combustione
Blu 500 P AB
• Tutti i bruciatori Low NOx garantiscono elevati
standard qualitativi e assicurano alta efficienza e
affidabilità di funzionamento.
NOISE LEVEL / LIVELLO DI RUMOROSITA’
dB (A) 80
80
78
75
70
74
73
71
71
68
70
69
60
60
50
50
40
40
30
30
20
20
10
10
0
Blu 500.1 P AB
1° stage
1° stadio
0
Blu 700.1 P AB
Blu 1000.1 P AB
Blu 1400.1 P AB
Data registered from the test done with the distance of 1 metre from the burner.
Misure effettuate in laboratorio ad 1 metro di distanza dal bruciatore.
2° stage
2° stadio
NOx
(mg/kWh)
EMISSION LEVEL / LIVELLO DI EMISSIONI
120 CO
(mg/kWh)
120
≤ 120 mg/kWh
Class 2-EN 676
100
LRV 92 Svizzera
Class 3-EN 676
100
≤ 80 mg/kWh
80
RAL UZ 80 - 41 Germania
Belgio
≤ 70 mg/kWh
80
70
60
60
Classi normativa EN 676
40
NOx
mg/kWh
170
120
80
classe
1
2
3
LRV 92 Svizzera
LRV 92 Svizzera
RAL UZ 80 - 41
Germania
EN 676
Belgio
40
20
20
NOx (Standard)
0
0
NOx (Low NOx)
CO (Standard)
Blu 500
Blu 700
Blu 1000
Blu 1400
Blu 500.1 LOW NOx
Blu 700.1 LOW NOx
Blu 1000.1 LOW NOx
Blu 1400.1 LOW NOx
CO (Low NOx)
Data from the test done on the boiler as per EN676 at maximum output.
Dati relativi a misure effettuate su caldaia secondo EN676 al carico massimo.
WORKING FIELDS / CAMPI DI LAVORO
mbar 9
PRESSURE IN THE COMBUSTION CHAMBER
PRESSIONE IN CAMERA DI COMBUSTIONE
8
7
6
5
4
Blu 1000.1 Low NOx
3
Blu 700.1 Low NOx
2
Blu 500.1 Low NOx
1
Blu 1400.1 Low NOx
0
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 kW
100
200
300
400
500
600
700
800
900
1000
kcal/h
1100 x 1000
BURNER OUTPUT / POTENZA
TECHNICAL DATA / DATI TECNICI
Output
Potenza termica
max.
kW
kcal/hx1000
Output
Gas pressure
Potenza termica
Pressione
min.
gas
kW
kcal/hx1000
mbar
Power
supply
Tensione
V
Motor
Motore
BLU 500.1 Low NoX
500
430
230
197,8
20 ÷ 300
230/400
0,55
P AB-PR-MD
BLU 700.1 Low NoX
700
602
270
232,2
20 ÷ 300
230/400
0,74
P AB-PR-MD
BLU 1000.1 Low NoX
875
752,5
280
240,8
20 ÷ 300
230/400
1,1
P AB-PR-MD
BLU 1400.1 Low NoX
1.100
946
290
249,4
20 ÷ 300
230/400
2,2
P AB-PR-MD
MODELS
Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3)
Operation
Funzionamento
kW
Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3)
GAS TRAIN / RAMPE GAS
Dungs SV-SVDLE
1
2
3
4
5
6
7
8
To be supplied by the installer
Accessori
cura
dell’installatore
accessori a a
cura
dell'installatore
1
1
2
3
4
5
6
7
8
8
-
2
3
5
4
8
6
7
2
3
5
8
1
1
2
3
5
6
7
6
Main gas pipe / Tubo gas
Ball valve / Valvola a sfera
Antivibration coupling / Giunto antivibrante
Gas governor / Stabilizzatore gas
Gas pressure switch / Pressostato gas
Safety gas valve / Valvola di sicurezza
Working gas valve / Valvola di lavoro
Leakage control / Controllo di tenuta
Landis VGD...
Main gas pipe / Tubo gas
Ball valve / Valvola a sfera
Antivibration coupling / Giunto antivibrante
Gas filter / Filtro gas
Gas pressure switch / Pressostato gas
Actuator / Attuatore
Actuator / Attuatore
Gas valve / Valvola gas
Leakage control / Controllo di tenuta
Dungs MB-MBDLE
1
-
-
2
3
4
5
9
6
7
Main gas pipe / Tubo gas
Ball valve / Valvola a sfera
Antivibration coupling / Giunto antivibrante
Gas pressure switch / Pressostato gas
Gas valve / Valvola gas
Leakage control / Controllo di tenuta
7
HOW TO CALCULATE THE OVERALL DIMENSION OF BURNER
COMPLETE WITH THE MATCHING GAS TRAIN
COME CALCOLARE LE DIMENSIONI TOTALI DEL BRUCIATORE E
DELLA RAMPA GAS CORRISPONDENTE
In order to calculate the overall dimension of the burner
complete with gas train, you need to consider value “N”
and “V” indicated in the burner leaflet and the dimension, of
the matching gas train choosen, according to the inlet gas
pressure available in the gas train leaflet.
Per calcolare l’ingombro totale del bruciatore completo di
rampa gas si deve far riferimento alla misure “N” and “V” che
sono indicate nel libretto del bruciatore e alle dimensioni
della corrispondente rampa gas scelta in base alla tavola di
accoppiamenti disponibile nel libretto rampe.
Blu 500-1400
Blu 1700.1-12000.1
Et = A + B + P + V + N
Et = A + B + P + N
Ct = U + R
Ct = O+ R
OVERALL DIMENSIONS / DIMENSIONI
A
E
D-D1
B
C
Blu 170 ÷ Blu 250
G
F
I
M
A
B
D - D1
C
O
G
F
E
H
N
A
E
D - D1
B
Blu 350 ÷ Blu15000.1
C
F
I
I
0 1
2
3
G
N
L
O
O
H
M
MODELS
BLU 170
BLU 250
BLU 350
A
B
C
D
D1
E
F
G
H
I
L
M
N
O
550
550
520
200
200
160
350
350
360
180
180
200
280
280
320
360
360
385
120
120
138
275
275
275
-
185
185
190
190
M8
M8
M8
-
-
Dimensions refer to the burner with gas train / Le dimensioni si riferiscono ai bruciatori con rampa gas.
MODELS
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
A
500
650
500.1 LOW NOx 650
700
650
700.1 LOW NOx 650
1000
650
1000.1 LOW NOx 650
1200
670
1400
670
1400.1 LOW NOx 670
1700.1
710
2000.1
730
3000.1
941
4000.1
941
5000.1
1019
6000.1
1069
7000.1
1210
8000.1
1280
10000.1
1310
12000.1
1420
15000.1
1670
B
C
D
D1
E
F
330
330
330
330
330
330
350
350
350
385
405
448
448
495
545
585
655
685
795
800
320
320
320
320
320
320
320
320
320
325
325
493
493
524
524
625
625
625
625
870
175
175
175
175
175
175
310
310
310
340
345
330
365
375
375
470
470
470
470
457
335
335
395
395
395
395
460
460
460
540
545
530
565
575
575
-
555
555
555
555
555
555
555
555
555
680
680
780
780
970
970
1212
1212
1212
1212
1750
160
160
180
170
190
190
215
215
200
250
270
290
320
320
320
420
420
420
450
500
G
H
385 165*225•
385 165*225•
385 225•
385 225•
385 225•
385 225•
385 225•
385 225•
385 225•
398 283•
398
283
466
280
466
280
565
400
565
400
800
480
800
480
800
480
800
480
1100 530
I
L
M
N
O
190
190
190
190
190
190
190
190
190
240
240
315
315
330
330
460
460
460
460
620
190
190
190
190
190
190
190
190
190
240
240
315
315
330
330
460
460
460
460
620
M10
M10
M10
M10
M10
M10
M10
M10
M10
M14
M14
M16
M16
M16
M16
M20
M20
M20
M20
M20
115
115
115
115
115
115
115
115
115
125
125
195
195
195
195
195
195
195
195
195
165
165
165
165
165
165
165
165
165
250
250
250
250
250
250
232
232
232
232
255
Dimensions refer to the burner without gas train / Le dimensioni si riferiscono ai bruciatori senza rampa gas.
D = short head / testa corta
D1= long head / testa lunga * = for Ecomax / per Ecomax
• = silencer optional /silenziatore opzionale
Dimension (mm) / Dimensioni (mm)
FB-Blu GB-IT 21-02-2005
Ecoflam S.p.A. RESERVES THE RIGHT TO MAKE ANY ADJUSTMENTS, WITHOUT PRIOR NOTICE, WHICH IT CONSIDER NECESSARY OR USEFUL TO ITS PRODUCTS, WITHOUT AFFECTING THEIR MAIN FEATURES.
Ecoflam S.p.A. SI RISERVA IL DIRITTO DI APPORTARE AI PRODOTTI, SENZA ALCUN PREAVVISO, TUTTE QUELLE MODIFICHE CHE RITERRA’ UTILI E/O NECESSARIE, AL FINE DI MIGLIORARNE LA QUALITA’, SENZA PREGIUDICARNE LE CARATTERISTICHE PRINCIPALI.
ECOFLAM S.P.A. - via Roma, 64 - 31023 Resana (TV) - Italy
tel. 0423.7160 - 715345 r.a. - fax 0423.715444 - 715538
http://www.ecoflam.it - e-mail: [email protected]
Scarica

LOW NOx - S & T group