va ila a LOWNO x re q u e st E flam co ble o n m Ecofla BLU GAS BURNERS BRUCIATORI DI GAS Ecoflam was founded in 1973 in Castelfranco Veneto, near Venice in the North East of Italy. For more than thirty years Ecoflam has continued to develop all its products with constant dedication and determination addressing Technological Research, Ecology, Energy Saving, and Safety. Ecoflam today offers a full range of blown air pressure jet burners designed and tested in our “GREEN” modern laboratories. All products conform to CE standards and are manufactured in accordance with ISO 9001 and VISION 2000 certification. Ecoflam burners guarantee high efficiency and reliable operation with significant energy savings. All models feature extreme ease of installation maintenance and flexible boiler - burner matching. Ecoflam nasce nel 1973 a Castelfranco Veneto, vicino a Venezia, nel cuore del Nord Est dell‘Italia. Da oltre trenta anni Ecoflam ha continuato a sviluppare tutti i prodotti con costante dedizione e determinazione rivolgendo particolare attenzione alla ricerca tecnologica, all’ecologia, al risparmio energetico e alla sicurezza. Ecoflam oggi è in grado di offrire una gamma completa di bruciatori ad aria soffiata completamente progettati e sviluppati nei moderni laboratori della divisione GREEN (Gruppo Ricerca Ecoflam Energia). Tutti i prodotti sono soggetti a severi controlli e collaudi, rispettano le norme CE e sono certificati ISO 9001 e VISION 2000. I bruciatori Ecoflam garantiscono un’alta efficienza e affidabilità di funzionamento unito a un notevole risparmio energetico. Tutti i modelli si caratterizzano per un’estrema facilità di installazione e manutenzione e flessibilità di accoppiamento con qualsiasi tipo di generatore. OPERATION / FUNZIONAMENTO P ...P AB ...PR ...MD On-Off Soft Start HI-LOW with servomotor Progressive Modulating 1 regime di fiamma (apertura lenta) 2 regimi di fiamma con servomotore Progressivo Modulante MAIN FEATURES / CARATTERISTICHE • Aluminium casing up to Blu P 4000.1 and steel casing from P 5000.1 with electrical panel integrated on the burner. • New high efficiency fan ventilator designed to give flame stability and easy matching. • Adjustable combustion head for fine tuning / matching with different shapes of combustion chamber. • Low NOx versions available from BLU 500.1 to 1400.1 ( Class 3 < 80mg/kWh, as per EN 676). BLU 2000.1 PAB • Hi - Low version with easy and fast butterfly ratio system available from Blu P 500 to Blu 2000.1. • Corpo in alluminio fino al Blu 4000.1 e in acciaio dal Blu 5000.1 con pannello elettrico integrato a bordo macchina. • Progressive version with electrical servomotor and adjustable mechanical cam that allows gas fine tuning. • Ventilatore al alta efficienza progettato per garantire stabilità della fiamma e facile accoppiamento. • Modulating version with PID system controller with digital set point display and real time value (PID RWF 40 or LMV 51/52 optional ). • Testa di combustione regolabile per garantire migliori accoppiamenti sui differenti camere di combustione. • Firing head with automatic adjustable system for primary air that changes according to output required from Blu P 7000.1. • Versione Low NOx dal Blu 500.1 al Blu 1400.1 (classe 3 < 80 mg/kWh in base alla norma EN676). • Easy maintenance of firing head from the burner top cover. • On request tailored solutions of flame shape. • Versione a due fiamme con nuovo sistema a farfalla di regolazione gas semplice e veloce, dal Blu 500.1 fino Blu 2000.1. • Bruciatori progressivi con servomotore ad alta coppia, e camma a profilo variabile per la regolazione fine del gas. • Versioni modulanti con termoregolatore PID con display digitale che visualizza il valore reale e permette di regolare il set point. • Sistema automatico di regolazione dell’aria primaria che varia in base alla portata richiesta dal Blu 7000.1. • Facile manutenzione grazie alla estrazione della testa di combustione dal retro del bruciatore . • A richiesta fiamma a geometria variabile. BLU 3000.1 MD WORKING FIELDS / CAMPI DI LAVORO mbar 6 PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 5 4 Blu 350 P/PAB Blu 250 P/PAB 3 2 Blu 170 P/PAB 1 0 50 75 60 80 100 100 120 125 140 150 160 180 175 200 200 220 225 240 260 250 280 275 300 kcal/h x 1000 300 320 340 360 kW BURNER OUTPUT / POTENZA mbar 9 Blu 700 P PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 8 Blu 500 P 7 6 5 4 Blu 1400 P AB 3 Blu 1000 P AB Blu 700 P AB Blu 500 P AB Blu 1200 P AB 2 1 0 200 100 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 1100 1200 1100 1300 kcal/h x 1000 kW BURNER OUTPUT / POTENZA TECHNICAL DATA / DATI TECNICI MODELS BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU 170 250 350 500 500 700 700 1000 1200 1400 Output Potenza termica max. kW kcal/hx1000 180 154,8 230 197,8 350 301 500 430 500 430 700 602 700 602 1.000 860 1.200 1.032 1.300 1.118 Output Gas pressure Potenza termica Pressione min. gas kW kcal/hx1000 mbar 89 76,54 20 ÷ 300 95 81,7 20 ÷ 300 147 126,42 20 ÷ 300 250 215,4 20 ÷ 300 190 163,4 20 ÷ 300 350 301 20 ÷ 300 250 215 20 ÷ 300 300 258 20 ÷ 300 400 344 20 ÷ 300 400 344 20 ÷ 300 Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3) Power supply Tensione V 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 Motor Motore kW 0,25 0,25 0,3 0,55 0,55 0,74 0,74 1,1 2,2 2,2 Operation Funzionamento P-P AB P-P AB P-P AB P P AB P P AB P AB P AB P AB Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3) WORKING FIELDS / CAMPI DI LAVORO mbar 9 8 PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 7 6 5 4 Blu 1400 PR/MD 3 2 Blu 500 PR/MD Blu 700 PR/MD Blu 1000 PR/MD Blu 1200 PR/MD 1 0 100 100 200 300 200 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 1100 kcal/h x 1000 1100 1200 kW 1300 BURNER OUTPUT / POTENZA mbar PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 12 10 8 6 Blu 1700.1 Blu 2000.1 4 2 0 200 200 400 600 600 400 800 800 1000 1000 1200 1200 1400 1400 1600 1600 kcal/h 2000 x 1000 1800 1800 2000 2200 kW BURNER OUTPUT / POTENZA TECHNICAL DATA / DATI TECNICI Output Potenza termica max. kW kcal/hx1000 Output Gas pressure Potenza termica Pressione min. gas kW kcal/hx1000 mbar Power supply Tensione V Motor Motore BLU 500 500 430 120 103,2 20 ÷ 300 230/400 0,55 PR-MD BLU 700 700 602 190 163,4 20 ÷ 300 230/400 0,74 PR-MD BLU 1000 1.000 860 200 172 20 ÷ 300 230/400 1,1 PR-MD BLU 1200 1.200 1.032 180 154,8 20 ÷ 300 230/400 2,2 PR-MD BLU 1400 1.300 1.118 250 215 20 ÷ 300 230/400 2,2 PR-MD BLU 1700.1 1.770 1.526 342 295 20 ÷ 300 230/400 3 P AB-PR-MD BLU 2000.1 2.150 1.853,45 414 356,9 20 ÷ 300 230/400 4 P AB-PR-MD MODELS Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3) Operation Funzionamento kW Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3) WORKING FIELDS / CAMPI DI LAVORO mbar 22 PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 20 18 Blu 5000.1 16 14 u Bl 12 60 00 u Bl 10 .1 40 00 8 .1 Blu 3000.1 6 4 2 0 500 1000 500 1500 1500 1000 2000 2000 2500 2500 3000 3000 3500 3500 4000 4000 4500 4500 5000 kcal/h x 1000 5000 kW 5500 BURNER OUTPUT / POTENZA mbar 40 38 36 34 32 PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 30 28 26 Blu Blu 10000.1 12 00 24 0.1 Blu 15000.1 22 20 18 Blu 16 80 00 14 .1 12 10 Blu 7000.1 8 6 4 2 0 1000 1000 2000 2000 3000 3000 4000 4000 5000 5000 6000 6000 7000 7000 8000 8000 9000 9000 10000 10000 11000 11000 12000 13000 12000 14000 13000 15000 14000 16000 15000 17000 kcal/h x 1000 kW BURNER OUTPUT / POTENZA TECHNICAL DATA / DATI TECNICI MODELS BLU BLU BLU BLU BLU BLU BLU BLU BLU 3000.1 4000.1 5000.1 6000.1 7000.1 8000.1 10000.1 12000.1 15000.1 Output Potenza termica max. kW kcal/hx1000 3.000 2.586 3.900 3.362 5.000 4.310 5.800 5.000 7.250 6.250 8.500 7.327,5 10.500 9.052 13.100 11.293,1 16.800 14.448 Output Gas pressure Potenza termica Pressione min. gas kW kcal/hx1000 mbar 630 543,1 40 ÷ 300 875 754,3 40 ÷ 300 1.200 1.034,5 40 ÷ 300 1.500 1.290 50 ÷ 500 1.500 1.290 50 ÷ 500 2.000 1.724 100 ÷ 500 2.500 2.155 100 ÷ 500 2.700 2.327,6 150 ÷ 500 3.464 2.986 200 ÷ 500 Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3) Power supply Tensione V 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 Motor Motore kW 5,5 7,5 11 15 15 18,5 22 37 45 Operation Funzionamento PR-MD PR-MD PR-MD PR-MD PR-MD PR-MD PR-MD PR-MD PR-MD Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3) DETAILS / PARTICOLARI RWF 40 Regulator Progressive version with servomotor and adjustable mechanical cam Regolatore RWF 40 Butterfly valve Valvola a farfalla Blu 500÷1400 PAB Servomotore con camma meccanica per versione progressiva Blu 8000.1 MD LMV51/52 System Sistema LMV51/52 Modulating version with PID regulated (proportional, integral and derivative) digital control board. Versione Modulante regolatore digitale PID. Integrated electric panel Pannello elettrico integrato Blu 500÷1400 PAB Diffuser Diffusore Blu 500 P AB Diffuser Diffusore Blu 8000.1 PR/MD LOW NOx E re q u e st flam co va ila a LOWNO x ble o n m Ecofla • The new range of Ecoflam Low NOx gas burners is the direct response to the need to reduce atmospheric pollutants in particular acid rain. • The new Ecoflam engineered and designed combustion heads enable the burners to surpass the most stringent regulations and standards regarding pollutant emissions, see emission classification table. • The new range of Low NOx gas burners are built to the highest quality and engineering standards as expected from Ecoflam thus ensuring high efficiency and reliable operation. • I nuovi bruciatori Ecoflam Low NOx a basse emissioni di ossidi azoto rappresentano la soluzione diretta all’inquinamento atmosferico ed in particolare alle piogge acide. • Le nuove teste di combustione progettate nei laboratori Ecoflam permettono di rispettare a pieno le normative più restrittive sulle emissioni inquinanti (vedi tabella classe emissioni). Combustion head Testa di combustione Blu 500 P AB • Tutti i bruciatori Low NOx garantiscono elevati standard qualitativi e assicurano alta efficienza e affidabilità di funzionamento. NOISE LEVEL / LIVELLO DI RUMOROSITA’ dB (A) 80 80 78 75 70 74 73 71 71 68 70 69 60 60 50 50 40 40 30 30 20 20 10 10 0 Blu 500.1 P AB 1° stage 1° stadio 0 Blu 700.1 P AB Blu 1000.1 P AB Blu 1400.1 P AB Data registered from the test done with the distance of 1 metre from the burner. Misure effettuate in laboratorio ad 1 metro di distanza dal bruciatore. 2° stage 2° stadio NOx (mg/kWh) EMISSION LEVEL / LIVELLO DI EMISSIONI 120 CO (mg/kWh) 120 ≤ 120 mg/kWh Class 2-EN 676 100 LRV 92 Svizzera Class 3-EN 676 100 ≤ 80 mg/kWh 80 RAL UZ 80 - 41 Germania Belgio ≤ 70 mg/kWh 80 70 60 60 Classi normativa EN 676 40 NOx mg/kWh 170 120 80 classe 1 2 3 LRV 92 Svizzera LRV 92 Svizzera RAL UZ 80 - 41 Germania EN 676 Belgio 40 20 20 NOx (Standard) 0 0 NOx (Low NOx) CO (Standard) Blu 500 Blu 700 Blu 1000 Blu 1400 Blu 500.1 LOW NOx Blu 700.1 LOW NOx Blu 1000.1 LOW NOx Blu 1400.1 LOW NOx CO (Low NOx) Data from the test done on the boiler as per EN676 at maximum output. Dati relativi a misure effettuate su caldaia secondo EN676 al carico massimo. WORKING FIELDS / CAMPI DI LAVORO mbar 9 PRESSURE IN THE COMBUSTION CHAMBER PRESSIONE IN CAMERA DI COMBUSTIONE 8 7 6 5 4 Blu 1000.1 Low NOx 3 Blu 700.1 Low NOx 2 Blu 500.1 Low NOx 1 Blu 1400.1 Low NOx 0 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 kW 100 200 300 400 500 600 700 800 900 1000 kcal/h 1100 x 1000 BURNER OUTPUT / POTENZA TECHNICAL DATA / DATI TECNICI Output Potenza termica max. kW kcal/hx1000 Output Gas pressure Potenza termica Pressione min. gas kW kcal/hx1000 mbar Power supply Tensione V Motor Motore BLU 500.1 Low NoX 500 430 230 197,8 20 ÷ 300 230/400 0,55 P AB-PR-MD BLU 700.1 Low NoX 700 602 270 232,2 20 ÷ 300 230/400 0,74 P AB-PR-MD BLU 1000.1 Low NoX 875 752,5 280 240,8 20 ÷ 300 230/400 1,1 P AB-PR-MD BLU 1400.1 Low NoX 1.100 946 290 249,4 20 ÷ 300 230/400 2,2 P AB-PR-MD MODELS Fuel : Natural Gas (L.C.V. 8.570 kcal/Nm3), LPG (L.C.V. 22.260 kcal/Nm3) Operation Funzionamento kW Combustibile : Gas Naturale (P.C.I. 8.570 kcal/Nm3), GPL (P.C.I. 22.260 kcal/Nm3) GAS TRAIN / RAMPE GAS Dungs SV-SVDLE 1 2 3 4 5 6 7 8 To be supplied by the installer Accessori cura dell’installatore accessori a a cura dell'installatore 1 1 2 3 4 5 6 7 8 8 - 2 3 5 4 8 6 7 2 3 5 8 1 1 2 3 5 6 7 6 Main gas pipe / Tubo gas Ball valve / Valvola a sfera Antivibration coupling / Giunto antivibrante Gas governor / Stabilizzatore gas Gas pressure switch / Pressostato gas Safety gas valve / Valvola di sicurezza Working gas valve / Valvola di lavoro Leakage control / Controllo di tenuta Landis VGD... Main gas pipe / Tubo gas Ball valve / Valvola a sfera Antivibration coupling / Giunto antivibrante Gas filter / Filtro gas Gas pressure switch / Pressostato gas Actuator / Attuatore Actuator / Attuatore Gas valve / Valvola gas Leakage control / Controllo di tenuta Dungs MB-MBDLE 1 - - 2 3 4 5 9 6 7 Main gas pipe / Tubo gas Ball valve / Valvola a sfera Antivibration coupling / Giunto antivibrante Gas pressure switch / Pressostato gas Gas valve / Valvola gas Leakage control / Controllo di tenuta 7 HOW TO CALCULATE THE OVERALL DIMENSION OF BURNER COMPLETE WITH THE MATCHING GAS TRAIN COME CALCOLARE LE DIMENSIONI TOTALI DEL BRUCIATORE E DELLA RAMPA GAS CORRISPONDENTE In order to calculate the overall dimension of the burner complete with gas train, you need to consider value “N” and “V” indicated in the burner leaflet and the dimension, of the matching gas train choosen, according to the inlet gas pressure available in the gas train leaflet. Per calcolare l’ingombro totale del bruciatore completo di rampa gas si deve far riferimento alla misure “N” and “V” che sono indicate nel libretto del bruciatore e alle dimensioni della corrispondente rampa gas scelta in base alla tavola di accoppiamenti disponibile nel libretto rampe. Blu 500-1400 Blu 1700.1-12000.1 Et = A + B + P + V + N Et = A + B + P + N Ct = U + R Ct = O+ R OVERALL DIMENSIONS / DIMENSIONI A E D-D1 B C Blu 170 ÷ Blu 250 G F I M A B D - D1 C O G F E H N A E D - D1 B Blu 350 ÷ Blu15000.1 C F I I 0 1 2 3 G N L O O H M MODELS BLU 170 BLU 250 BLU 350 A B C D D1 E F G H I L M N O 550 550 520 200 200 160 350 350 360 180 180 200 280 280 320 360 360 385 120 120 138 275 275 275 - 185 185 190 190 M8 M8 M8 - - Dimensions refer to the burner with gas train / Le dimensioni si riferiscono ai bruciatori con rampa gas. MODELS BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU BLU A 500 650 500.1 LOW NOx 650 700 650 700.1 LOW NOx 650 1000 650 1000.1 LOW NOx 650 1200 670 1400 670 1400.1 LOW NOx 670 1700.1 710 2000.1 730 3000.1 941 4000.1 941 5000.1 1019 6000.1 1069 7000.1 1210 8000.1 1280 10000.1 1310 12000.1 1420 15000.1 1670 B C D D1 E F 330 330 330 330 330 330 350 350 350 385 405 448 448 495 545 585 655 685 795 800 320 320 320 320 320 320 320 320 320 325 325 493 493 524 524 625 625 625 625 870 175 175 175 175 175 175 310 310 310 340 345 330 365 375 375 470 470 470 470 457 335 335 395 395 395 395 460 460 460 540 545 530 565 575 575 - 555 555 555 555 555 555 555 555 555 680 680 780 780 970 970 1212 1212 1212 1212 1750 160 160 180 170 190 190 215 215 200 250 270 290 320 320 320 420 420 420 450 500 G H 385 165*225• 385 165*225• 385 225• 385 225• 385 225• 385 225• 385 225• 385 225• 385 225• 398 283• 398 283 466 280 466 280 565 400 565 400 800 480 800 480 800 480 800 480 1100 530 I L M N O 190 190 190 190 190 190 190 190 190 240 240 315 315 330 330 460 460 460 460 620 190 190 190 190 190 190 190 190 190 240 240 315 315 330 330 460 460 460 460 620 M10 M10 M10 M10 M10 M10 M10 M10 M10 M14 M14 M16 M16 M16 M16 M20 M20 M20 M20 M20 115 115 115 115 115 115 115 115 115 125 125 195 195 195 195 195 195 195 195 195 165 165 165 165 165 165 165 165 165 250 250 250 250 250 250 232 232 232 232 255 Dimensions refer to the burner without gas train / Le dimensioni si riferiscono ai bruciatori senza rampa gas. D = short head / testa corta D1= long head / testa lunga * = for Ecomax / per Ecomax • = silencer optional /silenziatore opzionale Dimension (mm) / Dimensioni (mm) FB-Blu GB-IT 21-02-2005 Ecoflam S.p.A. RESERVES THE RIGHT TO MAKE ANY ADJUSTMENTS, WITHOUT PRIOR NOTICE, WHICH IT CONSIDER NECESSARY OR USEFUL TO ITS PRODUCTS, WITHOUT AFFECTING THEIR MAIN FEATURES. Ecoflam S.p.A. SI RISERVA IL DIRITTO DI APPORTARE AI PRODOTTI, SENZA ALCUN PREAVVISO, TUTTE QUELLE MODIFICHE CHE RITERRA’ UTILI E/O NECESSARIE, AL FINE DI MIGLIORARNE LA QUALITA’, SENZA PREGIUDICARNE LE CARATTERISTICHE PRINCIPALI. ECOFLAM S.P.A. - via Roma, 64 - 31023 Resana (TV) - Italy tel. 0423.7160 - 715345 r.a. - fax 0423.715444 - 715538 http://www.ecoflam.it - e-mail: [email protected]