Luca Stanco - INFN Padova Krakow, 28 September 1999 1 Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up etc. Luca Stanco - INFN Padova RMUON BMUON 2 Luca Stanco - INFN Padova ~ 3 600 LSTs (with lenght from 0.7 to 10.2 m) ~ 43 000 8-bit analog channels ~ 29 000 digital channels Area detector > 2 000 m2 Resolution: 1 mm in the “strip” view 3 mm in the “wire” view Technical Coordinator: Riccardo Brugnera Web-master: Vincenzo Chiochia 3 Luca Stanco - INFN Padova Mortality... year BMUI BMUO RMUI RMUO Total Ch72 1994 78 59 41 23 201 34 1995 - - - - - - 1996 78 59 42 23 202 36 1997 79 59 45 33 216 25 1998 81 66 50 41 238 25 1999 81/708 66/1502 50/480 41/704 238/3394 25/184 plus ~ 68 LST in trip for 10-40% of time plus ~ 10 LST in trip for 10-40% of time 4 Luca Stanco - INFN Padova Dead LST’s are normally switched off Simulation in the Monte Carlo via an EAZE job: to evaluate efficiency dependence (small effect: 5%) BMUON - MC ideal efficiency - - MC with dead LST RMUON 5 Luca Stanco - INFN Padova Slot 8: Elastic Slot 10: Inner BMUON Slot 11: Inner RMUON Slot 14: Outer BMUON Slot 15: Outer RMUON Inner Outer • GLOMU • GLOEXO 6 Luca Stanco - INFN Padova rates... 1 mb for L = 10*1030 10 Hz (most of the runs 7 Luca Stanco - INFN Padova with INNER chambers and with ISOMU: Calorimeter regions 8 Luca Stanco - INFN Padova rates INNER OUTER 9 Luca Stanco - INFN Padova GLOMU rates cosmics 30 nb for L = 10*1030 0.03 Hz 10 Luca Stanco - INFN Padova independent setup: efficiency vs HV working value 11 to reduce trips Luca Stanco - INFN Padova 100% HV: 4700 88% 100% HV: 4550 75% include inefficiency factor on single LSTin the Monte Carlo (15%) 12 Luca Stanco - INFN Padova - MC ideal - - MC with dead LST and 15% factor for HV efficiency BMUON RMUON 15% inefficiency coherent with analysis of single track segment ! 13 Luca Stanco - INFN Padova Check efficiency with DATA themselves ! Two independent analysis on 2 track m+m- clean events (3 different set of events, depending of the trigger) BMUON SET 1 SET 2 14 Luca Stanco - INFN Padova Monte Carlo is off of an overall factor ! A few investigations performed. Not yet found out the reason... … much more in Alessandro Bertolin’ talk this afternoon 15 Luca Stanco - INFN Padova VMS computer for DAQ • patch from DEC (and spare mVAX from DELPHI available) • upgrade on going ... Slow Control with OS9 (version 2.3 NOT good) • manual patch (bring time back, uff !) … • upgrade to 3.03 ? 16 Luca Stanco - INFN Padova problem while Aborting Run ? Time for Aborting as function of Run ... 17 Luca Stanco - INFN Padova Distribution of Time for Aborting ... for last positron runs... 18 Luca Stanco - INFN Padova • Good general behaviour of the detector • Triggers under control • Efficiency studies on the way on • Few upgrades needed for next millenium Good perspectives for next millenium Runs 19 Luca Stanco - INFN Padova