RinNOVA SOLAR IN: GESTIONE ZONE
SCHEMA IDRAULICO DI PRINCIPIO
•
•
Service
IL SISTEMA RinNOVA SOLAR IN PUO’
ESSERE DOTATO DI COMPENSATORE
IDRAULICO PER LA GESTIONE DI 3
ZONE RISCALDAMENTO.
A SECONDA DEL PACCHETTO SCELTO
SONO DISPONIBILI:
–
–
–
–
–
KIT 2 ZONE AT
KIT 2 ZONE BT
KIT 1 ZONA AT + 1 ZONA BT
KIT 1 ZONA AT + 2 ZONE BT
KIT NESSUNA ZONA
RinNOVA SOLAR IN: GESTIONE ZONE
COMPONENTI DEL KIT DISTRIBUZIONE
Service
I VARI KIT SONO COSI’ COMPOSTI
• KIT 2 ZONE AT
– N° 2 POMPE ASKOLL 15-60/130, 220V, 65 W
•
KIT 2 ZONE BT
– N° 2 POMPE ASKOLL 15-60/130, 220V 65 W
– N°2 MISCELATRICI, 220 V, 1 W
– NTC + TERMOSTATO MAX TEMPERATURA SU TUBI
MANDATA ZONA
•
KIT 1 ZONA AT + 1 ZONA BT
– N°2 POMPE ASKOLL 15-60/130, 220 V 65 W
– N°1 MISCELATRICE, 220 V, 1 W
– NTC + TERMOSTATO MAX TEMPERATURA SU TUBI
MANDATA ZONA
•
KIT 1 ZONA AT + 2 ZONE BT
– N°3 POMPE ASKOLL 15-60/130, 220V, 65 W
– N°2 MISCELATRICI , 220 V, 1 W
– NTC + TERMOSTATO MAX TEMPERATURA SU TUBI
MANDATA ZONA
•
KIT NESSUNA ZONA
– TUBI MANTATA IMPIANTO
•
TUTTI I KIT SONO DOTATI DI CENTRALINA
GESTIONE ZONE
RinNOVA SOLAR IN: GESTIONE ZONE
COMPENSATORE IDRAULICO
Service
COMPITO
• SEPARARE IDRAULICAMENTE IL
CIRCUITO RISCALDAMENTO PRIMARIO
DAL CIRCUITO DI DISTRIBUZIONE;
• PERMETTE DI DIFFERENZIARE LE
PORTATE PER LE VARIE ZONE
• IL SUO PRINCIPIO IDRAULICO
PERMETTE, SENZA PARTICOLARI
SISTEMI DI TARATURA, UNA BUONA
INDIPENDENZA TRA TUTTI I VARI
CIRCUITI
CARATTERISTICHE
• LA SUA PARTICOLARE
CONFORMAZIONE INTERNA PERMETTE
UNA MIGLIOR MISCELAZIONE DI TRA
MANDATA E RITORNO ED EVITA
“INQUINAMENTI” TRA I VARI CIRCUITI
COLLEGATI
RinNOVA SOLAR IN: GESTIONE ZONE
VALVOLA MISCELATRICE
Service
COMPITO
• MISCELARE ACQUA RITORNO IMPIANTO
E ACQUA DEL COMPENSATORE IN BASE
AI CALCOLI DELLA SCHEDA GESTIONE
ZONE;
CARATTERISTICHE
• 220 V, 1 W, ALIMENTATA A TRE FILI
• MANOPOLA REGOLAZIONE BY PASS
SEMPRE CHIUSA
• IL PASSAGGIO DELL’ACQUA DA
RITORNO A MANDATA RISCALDAMENTO
E’ GARANTITO DA UN CANALE TARATO
RinNOVA SOLAR IN: GESTIONE ZONE
VALVOLA MISCELATRICE
Service
RinNOVA SOLAR IN: GESTIONE ZONE
CIRCOLAZIONI ZONE MISCELATE
Service
NON RITORNO
VISTA GRUPPO DISTRIBUZIONE IN SEZIONE
• L’OTTURATORE DELLA MISCELATRICE E’ NORMALMENTE CHIUSO
• A FRONTE DI UNA RICHIESTA DALLA ZONA MISCLELATA L’OTTURATORE
INIZIA AD APRIRSI PER MISCELARE L’ACQUA CALDA DEL
COMPENSATORE CON QUELLA FREDDA DEL RITORNO
RinNOVA SOLAR IN: GESTIONE ZONE
CIRCOLAZIONE ZONE DIRETTE
Service
VISTA GRUPPO DISTRIBUZIONE IN SEZIONE
• A FRONTE DI UNA RICHIESTA DALLA ZONA ATA TEMPERATURA
VIENE ALIMENTATO IL CIRCOLATORE CHE SPILLA ACQUA
CALDA DIRETTAMENTE DAL COMPENSATORE
RinNOVA SOLAR IN: GESTIONE ZONE
DATI TECNICI
Service
ZONA MISCELATA
• RANGE: 25-45 °C
• T.MAX: 55 ° C
ZONA DIRETTA
• RANGE: 30-80 °C
• T.MAX: NON PRESENTE
ZONA MISCELATA
• RANGE: 25-45 °C
• T.MAX: 55 ° C
RinNOVA SOLAR IN: GESTIONE ZONE
COLLEGAMENTI ELETTRICI
Service
COLLEGAMENTI ELETTRICI
VANNO REALIZZATI I SEGUENTI COLLEGAMENTI (Indicati in rosso nello schema):
• ALIMENTAZIONE ELETTRICA
• SONDA ESTERNA E COMANDO REMOTO ZONA 1 BT (FORNITO DI SERIE)
• LINEA SERIALE TRA SCHEDA GESTIONE ZONE (SCHEDA INTERFACCIA) E CALDAIA
(LINEA COMANDO REMOTO)
• COMANDI REMOTO OPTIONAL E/O CRONOTERMORMOSTATI PER ZONE 2 E 3
RinNOVA SOLAR IN: GESTIONE ZONE
COLLEGAMENTI ELETTRICI
Service
COLLEGAMENTI ELETTRICI MULTIREMOTO
• SE SI COLLEGANO PIU’ COMANDI REMOTI, QUESTI DEVONO ESSERE
COLLEGATI IN SERIE TRA DI LORO
•UNA VOLTA INSTALLATI E’ NECESSARIO
SETTARE IL PARAMETRO “ZONE” SU OGNI
REMOTO
•IL REMOTO CHE AVRA’ IL PARAMETRO
“ZONE = 1” (OBBLIGATORIAMENTE ZONA
IN BASSA TEMPERATURA) PRENDERA’ LA
FUNZIONE DI REMOTO MASTER E QUINDI
L’UNICO CHE CONTROLLERA’ LA CALDAIA
RinNOVA SOLAR IN: GESTIONE ZONE
PRINCIPIO DI FUNZIONAMENTO
Service
TERMOREGOLAZIONE
IL SISTEMA E’ DOTATO DI SERIE DI:
• SONDA ESTERNA (DA COLLEGARE ALLA CENTRALINA GESTIONE ZONE)
• N°1 COMANDO REMOTO PER GESTIONE TEMPERATURA AMBIENTE ZONA 1 (DA
COLLEGARE ALLA CENTRALINA GESTIONE ZONE OBBLIGATORIAMENTE PER
GESTIRE UNA ZONA BASSA TEMPERATURA);
• SOLO IL COLLEGAMENTO DI ALMENO UN COMANDO REMOTO PUO’ ATTIVARE
LA COMUNICAZIONE SERIALE TRA SCHEDA GESTIONE ZONE E CALDAIA;
• GRAZIE ALLA COMUNICAZIONE SERIALE LA CALDAIA IMPOSTA LA
TEMPERATURA DI MANDATA AL COMPENSATORE IN FUNZIONE DI QUALE ZONA
CHIEDE POTENZA.
• LA LETTURA DELLA SONDA ESTERNA
PERMETTE ALLA SCHEDA GESTIONE ZONE DI
FAR LAVORARE LA MISCELATRICE.
• L’INSTALLAZIONE DI ALTRI COMANDI REMOTI
E’ OPZIONALE
RinNOVA SOLAR IN: GESTIONE ZONE