Service RinNOVA SOLAR IN Gestione zone RinNOVA SOLAR IN: GESTIONE ZONE SCHEMA IDRAULICO DI PRINCIPIO • • Service IL SISTEMA RinNOVA SOLAR IN PUO’ ESSERE DOTATO DI COMPENSATORE IDRAULICO PER LA GESTIONE DI 3 ZONE RISCALDAMENTO. A SECONDA DEL PACCHETTO SCELTO SONO DISPONIBILI: – – – – – KIT 2 ZONE AT KIT 2 ZONE BT KIT 1 ZONA AT + 1 ZONA BT KIT 1 ZONA AT + 2 ZONE BT KIT NESSUNA ZONA RinNOVA SOLAR IN: GESTIONE ZONE COMPONENTI DEL KIT DISTRIBUZIONE Service I VARI KIT SONO COSI’ COMPOSTI • KIT 2 ZONE AT – N° 2 POMPE ASKOLL 15-60/130, 220V, 65 W • KIT 2 ZONE BT – N° 2 POMPE ASKOLL 15-60/130, 220V 65 W – N°2 MISCELATRICI, 220 V, 1 W – NTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONA • KIT 1 ZONA AT + 1 ZONA BT – N°2 POMPE ASKOLL 15-60/130, 220 V 65 W – N°1 MISCELATRICE, 220 V, 1 W – NTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONA • KIT 1 ZONA AT + 2 ZONE BT – N°3 POMPE ASKOLL 15-60/130, 220V, 65 W – N°2 MISCELATRICI , 220 V, 1 W – NTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONA • KIT NESSUNA ZONA – TUBI MANTATA IMPIANTO • TUTTI I KIT SONO DOTATI DI CENTRALINA GESTIONE ZONE RinNOVA SOLAR IN: GESTIONE ZONE COMPENSATORE IDRAULICO Service COMPITO • SEPARARE IDRAULICAMENTE IL CIRCUITO RISCALDAMENTO PRIMARIO DAL CIRCUITO DI DISTRIBUZIONE; • PERMETTE DI DIFFERENZIARE LE PORTATE PER LE VARIE ZONE • IL SUO PRINCIPIO IDRAULICO PERMETTE, SENZA PARTICOLARI SISTEMI DI TARATURA, UNA BUONA INDIPENDENZA TRA TUTTI I VARI CIRCUITI CARATTERISTICHE • LA SUA PARTICOLARE CONFORMAZIONE INTERNA PERMETTE UNA MIGLIOR MISCELAZIONE DI TRA MANDATA E RITORNO ED EVITA “INQUINAMENTI” TRA I VARI CIRCUITI COLLEGATI RinNOVA SOLAR IN: GESTIONE ZONE VALVOLA MISCELATRICE Service COMPITO • MISCELARE ACQUA RITORNO IMPIANTO E ACQUA DEL COMPENSATORE IN BASE AI CALCOLI DELLA SCHEDA GESTIONE ZONE; CARATTERISTICHE • 220 V, 1 W, ALIMENTATA A TRE FILI • MANOPOLA REGOLAZIONE BY PASS SEMPRE CHIUSA • IL PASSAGGIO DELL’ACQUA DA RITORNO A MANDATA RISCALDAMENTO E’ GARANTITO DA UN CANALE TARATO RinNOVA SOLAR IN: GESTIONE ZONE VALVOLA MISCELATRICE Service RinNOVA SOLAR IN: GESTIONE ZONE CIRCOLAZIONI ZONE MISCELATE Service NON RITORNO VISTA GRUPPO DISTRIBUZIONE IN SEZIONE • L’OTTURATORE DELLA MISCELATRICE E’ NORMALMENTE CHIUSO • A FRONTE DI UNA RICHIESTA DALLA ZONA MISCLELATA L’OTTURATORE INIZIA AD APRIRSI PER MISCELARE L’ACQUA CALDA DEL COMPENSATORE CON QUELLA FREDDA DEL RITORNO RinNOVA SOLAR IN: GESTIONE ZONE CIRCOLAZIONE ZONE DIRETTE Service VISTA GRUPPO DISTRIBUZIONE IN SEZIONE • A FRONTE DI UNA RICHIESTA DALLA ZONA ATA TEMPERATURA VIENE ALIMENTATO IL CIRCOLATORE CHE SPILLA ACQUA CALDA DIRETTAMENTE DAL COMPENSATORE RinNOVA SOLAR IN: GESTIONE ZONE DATI TECNICI Service ZONA MISCELATA • RANGE: 25-45 °C • T.MAX: 55 ° C ZONA DIRETTA • RANGE: 30-80 °C • T.MAX: NON PRESENTE ZONA MISCELATA • RANGE: 25-45 °C • T.MAX: 55 ° C RinNOVA SOLAR IN: GESTIONE ZONE COLLEGAMENTI ELETTRICI Service COLLEGAMENTI ELETTRICI VANNO REALIZZATI I SEGUENTI COLLEGAMENTI (Indicati in rosso nello schema): • ALIMENTAZIONE ELETTRICA • SONDA ESTERNA E COMANDO REMOTO ZONA 1 BT (FORNITO DI SERIE) • LINEA SERIALE TRA SCHEDA GESTIONE ZONE (SCHEDA INTERFACCIA) E CALDAIA (LINEA COMANDO REMOTO) • COMANDI REMOTO OPTIONAL E/O CRONOTERMORMOSTATI PER ZONE 2 E 3 RinNOVA SOLAR IN: GESTIONE ZONE COLLEGAMENTI ELETTRICI Service COLLEGAMENTI ELETTRICI MULTIREMOTO • SE SI COLLEGANO PIU’ COMANDI REMOTI, QUESTI DEVONO ESSERE COLLEGATI IN SERIE TRA DI LORO •UNA VOLTA INSTALLATI E’ NECESSARIO SETTARE IL PARAMETRO “ZONE” SU OGNI REMOTO •IL REMOTO CHE AVRA’ IL PARAMETRO “ZONE = 1” (OBBLIGATORIAMENTE ZONA IN BASSA TEMPERATURA) PRENDERA’ LA FUNZIONE DI REMOTO MASTER E QUINDI L’UNICO CHE CONTROLLERA’ LA CALDAIA RinNOVA SOLAR IN: GESTIONE ZONE PRINCIPIO DI FUNZIONAMENTO Service TERMOREGOLAZIONE IL SISTEMA E’ DOTATO DI SERIE DI: • SONDA ESTERNA (DA COLLEGARE ALLA CENTRALINA GESTIONE ZONE) • N°1 COMANDO REMOTO PER GESTIONE TEMPERATURA AMBIENTE ZONA 1 (DA COLLEGARE ALLA CENTRALINA GESTIONE ZONE OBBLIGATORIAMENTE PER GESTIRE UNA ZONA BASSA TEMPERATURA); • SOLO IL COLLEGAMENTO DI ALMENO UN COMANDO REMOTO PUO’ ATTIVARE LA COMUNICAZIONE SERIALE TRA SCHEDA GESTIONE ZONE E CALDAIA; • GRAZIE ALLA COMUNICAZIONE SERIALE LA CALDAIA IMPOSTA LA TEMPERATURA DI MANDATA AL COMPENSATORE IN FUNZIONE DI QUALE ZONA CHIEDE POTENZA. • LA LETTURA DELLA SONDA ESTERNA PERMETTE ALLA SCHEDA GESTIONE ZONE DI FAR LAVORARE LA MISCELATRICE. • L’INSTALLAZIONE DI ALTRI COMANDI REMOTI E’ OPZIONALE RinNOVA SOLAR IN: GESTIONE ZONE