Solar Panel
Informazioni tecniche
VALVOLA DEVIATRICE MISCELATRICE
Patent Pending
Gruppo compatto
miscelatrice+deviatrice per caldaie
abbinate ad impianti solari
-1-
DIN type
116
42.5
73.5
out M I X
out ST
in ST
50
out M I X
in ST
in DC W
30
inDHW
out ST
inST
inDCW
out MIX
- ingressoacqua calda sanitaria <dalla Caldaia
- uscita acqua sanitaria Solar StorageTank >alla Caldaia
- ingressoacqua sanitaria <dal Solar StorageTank
- ingressoacqua fredda <dall’acquedotto
- uscita acqua calda miscelata >all’Utenza
-2-
G1/2”
BRAS
A ISI 304
E PDM
ABS
- fitting
- housing - cartridge
- filter – spring
- o.ring
- knob
Solar Panel
Patent Pending
TECHNICAL SPECIFICATION
Thermostatic Cartridge
- designed to meet standard NF EN 1111 and ASSE 1016
- SHUT-OFF (anti-burn) function (< 60°C)
- anti-legionella *
-
Schema idraulico
* LEGIONELLA (Gram negative batterium)
- survive with temp. 57- 63°C
- disinfection range storage tank >70°C
anti-limescale adherence
optimum operating pressure 1 to 10 bar
maximum static pressure 16 bar
minimum static pressure 0.5 bar ( with C resistance characteristic )
flow rate at 3 bar 25 l/min
thermostatic regulation range 30 - 56°C
temp. stability +/-1°C
presetting cartridge 38°C
servicing kit cartridge thermostatic presetting
mixing valve ( drop pressure ) kV = 2.1 ( 0.25 bar )
Diverting valve
- working temp. max 100°C
- presetting 3 way diverting valve 48°C (+/- 1)
- 3 way valve diverting ( drop pressure ) kV = 1.8 ( 0.30 bar )
COMPACT DHW group for Boiler
equipped with Solar Panel
Mixing.diverting.valve.din.ty
-3-
Scarica