Solar Panel Informazioni tecniche VALVOLA DEVIATRICE MISCELATRICE Patent Pending Gruppo compatto miscelatrice+deviatrice per caldaie abbinate ad impianti solari -1- DIN type 116 42.5 73.5 out M I X out ST in ST 50 out M I X in ST in DC W 30 inDHW out ST inST inDCW out MIX - ingressoacqua calda sanitaria <dalla Caldaia - uscita acqua sanitaria Solar StorageTank >alla Caldaia - ingressoacqua sanitaria <dal Solar StorageTank - ingressoacqua fredda <dall’acquedotto - uscita acqua calda miscelata >all’Utenza -2- G1/2” BRAS A ISI 304 E PDM ABS - fitting - housing - cartridge - filter – spring - o.ring - knob Solar Panel Patent Pending TECHNICAL SPECIFICATION Thermostatic Cartridge - designed to meet standard NF EN 1111 and ASSE 1016 - SHUT-OFF (anti-burn) function (< 60°C) - anti-legionella * - Schema idraulico * LEGIONELLA (Gram negative batterium) - survive with temp. 57- 63°C - disinfection range storage tank >70°C anti-limescale adherence optimum operating pressure 1 to 10 bar maximum static pressure 16 bar minimum static pressure 0.5 bar ( with C resistance characteristic ) flow rate at 3 bar 25 l/min thermostatic regulation range 30 - 56°C temp. stability +/-1°C presetting cartridge 38°C servicing kit cartridge thermostatic presetting mixing valve ( drop pressure ) kV = 2.1 ( 0.25 bar ) Diverting valve - working temp. max 100°C - presetting 3 way diverting valve 48°C (+/- 1) - 3 way valve diverting ( drop pressure ) kV = 1.8 ( 0.30 bar ) COMPACT DHW group for Boiler equipped with Solar Panel Mixing.diverting.valve.din.ty -3-