L’Azienda dell’Innovazione LTG Aktiengesellschaft Terminali ad induzione da incasso a pavimento Esempio: tipo HFB--D LTG Aktiengesellschaft D - 70435 Stuttgart, Grenzstraße 7 +49 (711) 82 01-180, Fax +49 (711) 82 01-720 Internet: http://www.LTG-AG.de E-Mail: info@LTG-- AG.de LTG Incorporated 105 Corporate Drive, Suite E Spartanburg S.C., 29303 USA +1 (864) 599-- 6340, Fax +1 (864) 599-- 6344 Internet: http://www.LTG-INC.net E-Mail: info@LTG-- INC.net LTG S.r.l. con socio unico Via G. Leopardi 10 I-- 20066 Melzo +39 (02) 9 55 05 35, Fax +39 (02) 9 55 08 28 Internet: http://www.LTG-SRL.com E-Mail:[email protected] Bodenind-I-TP-01 (09/07) 416-93 L’Azienda dell’Innovazione LTG Aktiengesellschaft Componenti per il condizionamento dell'aria Germania Filiale Centro (Frankfurt) Zona di vendita: PLZ 54, 55, 60, 63, 64, 66--69, 97 Sontraer Str. 27 D-60386 Frankfurt am Main (069) 94 20 19-14, Fax -10 E--mail: [email protected] Filiale Centro (Herborn) Zona di vendita: PLZ 30, 31, 34--38, 56, 57, 61, 65 Sperberweg 16 D-35745 Herborn Herr Hartmann (02772) 570--725, Fax -727 E--mail: [email protected] Filiale Est (Berlin) Zona di vendita: PLZ 10--25, 29, 39 Eisenhutweg 51a D--12487 Berlin Herr Linke (030) 63 22 87-74, Fax -75 E--mail: [email protected] Filiale Est (Chemnitz) Zona di vendita: PLZ 01--09, 98, 99 Johannes--Ebert--Straße 20 D--09128 Chemnitz Herr Schenfeld (0371) 77118--01, Fax -02 E--mail: [email protected] Filiale Sud Zona di vendita: PLZ 70--96 Grenzstraße 7 D--70435 Stuttgart Herr Gau (0711) 8201--209, Fax -210 E--mail: [email protected] Filiale Ovest Zona di vendita: PLZ 26--28, 32, 33, 40--53, 58--59 Baststraße 30 D--46119 Oberhausen/Rheinl. Herr Perenz (0208) 30431--55, Fax --56 E--mail: [email protected] Il programma Austria KTG Klimatechnische Gesellschaft mbH Schubertstraße 13, A--2126 Ladendorf (02575) 21089, Fax (02575) 21022 E--Mail: [email protected] Gran Bretagna MAP Motorised Air Products Ltd. Unit 5A, Sopwith Crescent Wickford Business Park Wickford GB--Essex SS11 8YU (01268) 57 44 42, Fax (01268) 57 44 43 E--Mail: [email protected] Paesi Bassi Opticlima Systems Leeuwerikstraat 110, NL--3853 AG Ermelo (0341) 493969, Fax (0341) 493931 E--Mail: [email protected] Slovenia Energo Plus Koprska 108 d, SLO-- 1000 Ljubljana (01) 200 73 67, Fax (01) 42 33 346 E--Mail: [email protected] Polonia HTK Went Sp.z.o.o. ul. Chopina 13/3, PL--30047 Krakow (012) 7632 31 32, Fax (012) 632 81 93 E--Mail: [email protected] Portogallo ArGelo S. A. R. Luis Pastor de Macedo, Lote 28 B P-1750--158 Lisboa (21) 752 01 20, Fax (21) 752 01 29 E--Mail: [email protected] Svizzera Laminair AG Kirchbergstrasse 105 Ch--3400 Burgdorf (034) 420 02--10, (034) 420 02--11 E--Mail: [email protected] Turchia Step Müh. Yapi Ltd. Componenti per il condizionamento dell'aria Diffusori da soffitto, da parete e da pavimento · LTG System cleanR · Diffusori lineari CoandatrolR · Diffusori da soffitto CoandaventR · Diffusori a dislocamento · Ventagli LTG cool waveR · Induttori KlimaventR · Ventilconvettori Raumluft · Ventilconv. da controsoffitto VentotelR · Regolatori di portata · LabairR --system · Servizi di ingegneria Servizi tecnici per investitori, architetti, progettisti e impiantisti durante la fase di pianificazione, costruzione e gestione di edifici. Dati affidabili e dettagliati in materia di componenti e sistemi di condizionamento dell’aria ambientale già prima della loro realizzazione, grazie a rilevamenti metrologici, calcoli, simulazioni degli edifici e prove sperimentali. _______________________________ Componenti per la ventilazione di processo Giappone Toho Engineering Co. Ltd. 14-11, Shimizu 3-Chome, Kita Ku Japan 462 Nagoya (052) 9 91-10 40, Fax (052) 9 14-98 22 E--Mail: [email protected] Il programma Componenti per la ventilazione di processo Ventilatori assiali, radiali e tangenziali · Collector--System per la filtrazione, la separazione, il compattamento, la pressatura e l’umidificazione. Servizi di ingegneria Servizi tecnici per progettisti e impiantisti durante la fase di pianificazione e costruzione. Yali Yolu Sokak, Turanli Apt. No: 24 D.1 TR-- 34744 Bostanci--Istanbul (0216) 445 2931, Fax (0216) 445 2505 E--Mail: [email protected] E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB Impiego Vantaggi I terminali ad induzione da incasso a pavimento tipo HFB sono del tipo a 2 o 4 tubi adatti al riscaldamento, il raffreddamento e la ventilazione di zone di permanenza (perimetrali), di fabbricati con carichi termici variabili. E’ particolarmente adatto all’inserimento in pavimenti rialzati con altezza (consigliata) tra 200 e 300 mm. Siccome tutti gli elementi che compongono l’induttore vanno a trovarsi sotto il livello del pavimento finito, gli induttori HFB sono particolarmente adatti per l’impiego in ambienti con facciate a vetri. • Impiego flessibile - la costruzione modulare permette l’allestimento progressivo da semplice convettore per il riscaldamento, a convettore ventilato fino ad arrivare all’induttore a 4 tubi, a seconda delle esigenze dell’utente. • Consumi energetici contenuti - bassi costi per il convogliamento dell’aria per la perdita di carico contenuta. - scambiatore di calore di ampia superficie per una convezione naturale in fase di riscaldamento • Altissimo comfort - comfort in fase di raffreddamento per la diffusione combinata a miscelazione e dislocamento - ottima schermatura di pareti vetrate d’inverno • Acustica - livello di potenza sonora molto basso - nessun trasferimento acustico da un ambiente all’altro attraverso il pavimento rialzato • Manutenzione - nessun organo in movimento, massima accessibilità attraverso la griglia di ventilazione • Montaggio - montaggio indipendente di induttore, parete esterna e pavimento rialzato - integrazione e adattamento flessibili e rapidi, costruzione modulare Induttore da incasso a pavimento tipo HFB--D (raffigurato apparecchio aperto -- versione speciale con 2 attacchi) Funzionamento L’aria primaria trattata nella centrale di condizionamento viene immessa tramite ugelli induttori ricambiabili (solo quelli in materiale sintetico) I filetti fluidi così prodotti inducono una grande quantità di aria secondaria, cioè aria ambiente risucchiata attraverso lo scambiatore di calore. Dopo una deviazione di 90_ la miscela di aria primaria-- ambiente viene scaricata verticalmente in ambiente attraverso una griglia a pavimento praticabile. Quest’aria di mandata si miscela d’estate con l’aria calda della facciata e d’inverno con l’aria fredda di caduta dinanzi alla vetrata (miscelazione in prossimità della facciata). In fase di raffreddamento l’aria di mandata attraversa con moto a dislocamento l’ambiente condizionato. A centrale di condizionamento spenta l’apparecchio può funzionare come convettore a pavimento. Versioni Il terminale ad induzione da incasso tipo HFB è fornito in due versioni: - HFB--Z Versione con scambiatore di calore a due file per rese caloriche elevate a fronte di elevati carichi d’aria primaria - HFB--D Versione con scambiatore di calore a tre file per rese caloriche elevate a fronte di bassi carichi d’aria primaria Entrambe le versioni sono offerte con le medesime lunghezze d’impianto, a pari larghezza della griglia. Induttore a pavimento tipo HFB con griglia di ventilazione in alluminio Tolleranze - Per le misure riportate in questo prospetto valgono le tolleranze secondo la norma DIN 2768-- vL. Per le griglie sono valide le tolleranze speciali come indicate. - Tolleranze di torsione e di rettilineità secondo la norma DIN EN 12020-- 2. Superficie - Le superfici sono finite per soddisfare le esigenze derivanti dall’impiego in impianti di condizionamento per edifici secondo la norma DIN 1946 parte 2. Per altre esigenze va fatta richiesta specifica. E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 3 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-D Dimensioni mand. freddo rit. freddo X 63 441 H 126 I Lato facciata 75 Vista dall’alto Ø 30 piedini regolabili DN 100 bocca premente B 320 Sezione X--X rit. caldo X 4 x DN 40 63 G regolabile +50 mm E mand. caldo asole di fissaggio F C/2 Rappresentazione isometrica C A 2 x LL 20 x 10,5 aria di immissione raffigurata: esecuzione con griglia in alluminio aria ambiente aria primaria Induttore tipo HFB- D Grand. 630 800 1000 1250 A 988 1198 1398 1598 Attenzione! Non usare il tubo come piano di appoggio B 626 856 1056 1256 C 593 763 963 1163 F 40 95 95 95 Versione griglia: in acciaio inox: a nastro in alluminio: in alluminio: E 305 308 308 H 44 48 48 I 55 59 59 Gmin 187 191 191 E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 4 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-D Datei tecnici Grandezza 630 VP ∆p LA184) LwA4) 3 [m /h] [Pa] [dB(A)] [dB(A)] 35 150 21 27 35 250 22 28 45 150 24 30 45 250 26 32 60 150 26 32 60 250 28 34 80 150 28 34 80 250 33 39 100 150 31 37 100 250 33 39 Grandezza 800 VP ∆p LA184) LwA4) [m3/h] [Pa] [dB(A)] [dB(A)] 45 150 22 28 45 250 23 29 60 150 24 30 60 250 25 31 80 150 26 32 80 250 30 36 100 150 29 35 100 250 31 37 120 150 32 38 120 250 34 40 1) 2) 3) 4) LA18 LwA QP ∆tP Qh Qk /∆t1) Qh /∆t [W/K] [W/K] 17 10 20 12 15 15 20 20 27 21 26 28 33 32 13 16 18 20 20 27 33 33 36 34 39 22 21 24 QP /∆tP [W/K] 15 Qk /∆t1) Qh /∆t [W/K] [W/K] 25 15 QEk3) [W] 180 QEk3) [W] wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] 170 200 QP2 [W] 120 120 210 260 280 330 320 150 150 200 200 270 360 340 380 270 330 330 wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] 250 QP2 [W] 150 100/1,2 100/1,8 15 20 31 34 19 20 310 340 150 200 20 27 27 39 38 43 24 23 26 390 380 430 200 270 270 33 33 40 46 25 28 400 460 330 330 40 40 43 48 26 29 430 480 400 400 225 120/2,5 120/3 con temperatura acqua di mandata a 16 _C; temperatura aria aspirata a 26 _C, funzionamento non condensante (la temperatura aria aspirata può discostarsi dalla temperatura ambiente) con temperatura aria primaria di 16 _C e temperatura aria aspirata a 26 _C con temperatura acqua di mandata a 70 _C e temperatura aria aspirata a 20 _C dati acustici validi per induttori con ugelli sintetici; con ugelli in alluminio considerare ca. 3 dB in più. VP ∆p Qk QP /∆tP [W/K] 12 12 - portata d’aria primaria (10%) - pressione statica sul canotto di entrata aria primaria - livello di pressione sonora con 18 m2 Sabine di assorbimento - livello di potenza sonora 3 dB(A) (con ugelli in materiale sintetico) - potenza frigorifera aria primaria - differenza di temperatura tra aria ambiente e aria primaria - potenza frigorifera secondaria (scambiatore di calore) - potenza calorifera secondaria ∆t QEk wok woh ∆pw - differenza di temperatura tra aria in aspirazione e acqua di mandata. - potenza calorifera a convezione naturale - portata d’acqua refrigerata nominale - portata d’acqua di riscaldamento nom. - perdita di carico lato acqua E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 5 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-D Datei tecnici Grandezza 1000 VP ∆p LA184) LwA4) 3 [m /h] [Pa] [dB(A)] [dB(A)] 60 150 22 28 60 250 24 30 80 150 26 32 80 250 29 35 100 150 28 34 100 250 31 37 120 150 30 36 120 250 33 39 140* 150 32 38 140* 250 35 41 Grandezza 1250 VP ∆p LA184) LwA4) [m3/h] [Pa] [dB(A)] [dB(A)] 80 150 25 31 80 250 28 34 100 150 27 33 100 250 30 36 120 150 30 36 120 250 32 38 140* 150 31 37 140* 250 34 40 160* 150 35 40 160* 250 36 43 1) 2) 3) 4) QP /∆tP [W/K] 20 20 Qk /∆t1) Qh /∆t [W/K] [W/K] 40 24 47 28 27 27 33 33 40 46 52 50 55 53 27 31 30 33 32 40 47 47 58 56 60 35 33 36 QP /∆tP [W/K] 27 Qk /∆t1) Qh /∆t [W/K] [W/K] 53 32 QEk3) [W] 280 QEk3) [W] wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] 400 470 QP2 [W] 200 200 460 510 500 550 530 270 270 330 330 400 580 560 600 400 470 470 wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] 530 QP2 [W] 270 150/4 150/4,6 27 33 58 57 35 34 580 570 270 330 33 40 40 61 62 67 37 38 41 610 620 670 330 400 400 47 47 68 71 42 44 680 710 470 470 53 53 73 76 45 47 730 760 530 530 345 180/5,8 180/7,5 con temperatura acqua di mandata a 16 _C; temperatura aria aspirata a 26 _C, funzionamento non condensante (la temperatura aria aspirata può discostarsi dalla temperatura ambiente) con temperatura aria primaria di 16 _C e temperatura aria aspirata a 26 _C con temperatura acqua di mandata a 70 _C e temperatura aria aspirata a 20 _C dati acustici validi per induttori con ugelli sintetici; con ugelli in alluminio considerare ca. 3 dB in più. * in caso di un quantitativo elevato di aria, per motivi acustici devono essere previsti 2 attacchi primari VP ∆p LA18 LwA QP ∆tP Qk Qh - portata d’aria primaria (10%) - pressione statica sul canotto di entrata aria primaria - livello di pressione sonora con 18 m2 Sabine di assorbimento - livello di potenza sonora 3 dB(A) (con ugelli in materiale sintetico) - potenza frigorifera aria primaria - differenza di temperatura tra aria ambiente e aria primaria - potenza frigorifera secondaria (scambiatore di calore) - potenza calorifera secondaria ∆t QEk wok woh ∆pw - differenza di temperatura tra aria in aspirazione e acqua di mandata. - potenza calorifera a convezione naturale - portata d’acqua refrigerata nominale - portata d’acqua di riscaldamento nom. - perdita di carico lato acqua E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 6 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-D Dimensionamento Induttore tipo HFB-D (4 tubi) batteria di raffreddamento. Perdita di carico lato acqua e potenza frigorifera con varie portate d'acqua 20 potenza frigorifera in % della potenza nominale Qk 120 perdita di carico lato acqua ∆pw [kPa] 10 100 5 2 Gr. 1250 Gr. 1000 Gr. 800 Gr. 630 1 0,5 40 90 140 80 60 40 190 20 40 60 80 100 120 140 portata d’acqua in % rispetto alla portata nom. portata d’acqua w [kg/h] Induttore tipo HFB-D (4 tubi) batteria di riscaldamento. Perdita di carico lato acqua e potenza calorifera con varie portate d'acqua 15 potenza calorifera in % della potenza nominale Qh 120 perdita di carico lato acqua ∆pw [kPa] 10 5 100 2 Gr. 1250 Gr. 1000 Gr. 800 Gr. 630 1 0,5 0,2 80 60 40 40 90 140 portata d’acqua w [kg/h] 190 20 40 60 80 100 120 portata d’acqua in % rispetto alla portata nom. E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 7 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-Z Dimensioni DN 100 rit. caldo 29,5 441 E 63 A 126 Vista dall’alto Lato facciata Ø 30 piedini regolabili I 4 x Di = Ø 40 H X mand. caldo G regolabile +50 mm X Ausblasbreite B 80 322 rit. freddo mand. freddo Dämmstreifen bauseits Schnitt X--X Rappresentazione isometrica C/2 asole di fissaggio 2 x LL 20 x 10,5 C F Attenzione! Non usare il tubo come piano di appoggio aria di immissione aria ambiente raffigurata: esecuzione con griglia in acciaio inox aria primaria Induttore tipo HFB- Z Grand. 630 800 1000 1250 A 988 1198 1398 1598 B 626 856 1056 1256 C 593 763 963 1163 F 40 95 95 95 Versione griglia: in acciaio inox: a nastro in alluminio: in alluminio: E 305 308 308 H 44 48 48 I 55 59 59 Gmin 187 191 191 E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 8 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-Z Datei tecnici Grandezza 630 VP ∆p LA184) LwA4) 3 [m /h] [Pa] [dB(A)] [dB(A)] 35 150 <22 <28 35 250 <22 <28 45 150 45 60 60 80 80 100 100 QP /∆tP [W/K] Qk /∆t1) Qh /∆t [W/K] [W/K] QEk3) [W] wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] QP2 [W] 12 16 13 160 120 12 18 15 180 120 26 15 17 15 170 150 250 150 250 <22 23 24 27 29 30 33 15 20 20 20 22 25 17 19 21 200 220 250 150 200 200 150 250 150 250 28 30 33 35 34 36 39 41 27 27 33 33 29 33 35 39 25 28 30 34 290 330 350 390 270 270 330 330 wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] QP2 [W] Grandezza 800 VP ∆p LA184) LwA4) 3 [m /h] [Pa] [dB(A)] [dB(A)] 45 150 <20 23 QP /∆tP [W/K] Qk /∆t1) Qh /∆t [W/K] [W/K] 165 QEk3) [W] 100/3 100/2 15 19 16 190 150 45 250 <20 25 15 23 19 230 150 60 150 25 20 25 21 250 200 60 80 250 150 <20 22 23 28 29 20 27 29 33 25 28 290 330 200 270 80 100 100 250 150 250 27 28 31 33 34 37 27 33 33 38 40 45 32 34 38 380 400 450 270 330 330 120 120 150 250 32 35 38 41 40 40 47 53 39 45 470 530 400 400 1) 2) 3) 4) LA18 LwA QP ∆tP Qh 120/5 120/3,3 con temperatura acqua di mandata a 16 _C; temperatura aria aspirata a 26 _C, funzionamento non condensante (la temperatura aria aspirata può discostarsi dalla temperatura ambiente) con temperatura aria primaria di 16 _C e temperatura aria aspirata a 26 _C con temperatura acqua di mandata a 70 _C e temperatura aria aspirata a 20 _C dati acustici validi per induttori con ugelli sintetici; con ugelli in alluminio considerare ca. 3 dB in più. VP ∆p Qk 210 - portata d’aria primaria (10%) - pressione statica sul canotto di entrata aria primaria - livello di pressione sonora con 18 m2 Sabine di assorbimento - livello di potenza sonora 3 dB(A) (con ugelli in materiale sintetico) - potenza frigorifera aria primaria - differenza di temperatura tra aria ambiente e aria primaria - potenza frigorifera secondaria (scambiatore di calore) - potenza calorifera secondaria ∆t QEk wok woh ∆pw - differenza di temperatura tra aria in aspirazione e acqua di mandata. - potenza calorifera a convezione naturale - portata d’acqua refrigerata nominale - portata d’acqua di riscaldamento nom. - perdita di carico lato acqua E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 9 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-Z Datei tecnici Grandezza 1000 VP ∆p LA184) LwA4) 3 [m /h] [Pa] [dB(A)] [dB(A)] 60 150 21 27 60 250 23 29 80 150 23 29 80 250 26 32 100 150 28 34 100 250 30 36 120 150 32 38 120 250 34 40 140* 150 35 41 140* 250 37 43 Grandezza 1250 VP ∆p LA184) LwA4) [m3/h] [Pa] [dB(A)] [dB(A)] 80 150 22 28 80 250 25 31 100 150 24 30 100 250 27 33 120 150 28 34 120 250 31 37 140* 150 32 38 140* 250 35 41 160* 150 35 41 160* 250 38 44 1) 2) 3) 4) QP /∆tP [W/K] 20 20 Qk /∆t1) Qh /∆t [W/K] [W/K] 34 28 39 33 27 27 33 33 40 38 44 43 49 47 32 37 36 41 39 40 47 47 54 51 58 45 43 49 QP /∆tP [W/K] 27 Qk /∆t1) Qh /∆t [W/K] [W/K] 45 36 QEk3) [W] 260 QEk3) [W] wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] 340 390 QP2 [W] 200 200 380 440 430 490 470 270 270 330 330 400 540 510 580 400 470 470 wok /∆pw woh /∆pw Qk1 [kg/h]/[kPa] [kg/h]/[kPa] [W] 450 QP2 [W] 270 150/10 150/6 27 33 51 52 43 44 510 520 270 330 33 40 40 59 56 63 50 47 53 590 560 630 330 400 400 47 47 60 68 51 58 600 680 470 470 53 53 65 73 55 62 650 730 530 530 325 180/16 180/10 con temperatura acqua di mandata a 16 _C; temperatura aria aspirata a 26 _C, funzionamento non condensante (la temperatura aria aspirata può discostarsi dalla temperatura ambiente) con temperatura aria primaria di 16 _C e temperatura aria aspirata a 26 _C con temperatura acqua di mandata a 70 _C e temperatura aria aspirata a 20 _C dati acustici validi per induttori con ugelli sintetici; con ugelli in alluminio considerare ca. 3 dB in più. * in caso di un quantitativo elevato di aria, per motivi acustici devono essere previsti 2 attacchi primari VP ∆p LA18 LwA QP ∆tP Qk Qh - portata d’aria primaria (10%) - pressione statica sul canotto di entrata aria primaria - livello di pressione sonora con 18 m2 Sabine di assorbimento - livello di potenza sonora 3 dB(A) (con ugelli in materiale sintetico) - potenza frigorifera aria primaria - differenza di temperatura tra aria ambiente e aria primaria - potenza frigorifera secondaria (scambiatore di calore) - potenza calorifera secondaria ∆t QEk wok woh ∆pw - differenza di temperatura tra aria in aspirazione e acqua di mandata. - potenza calorifera a convezione naturale - portata d’acqua refrigerata nominale - portata d’acqua di riscaldamento nom. - perdita di carico lato acqua E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 10 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB-Z Dimensionamento Induttore tipo HFB-Z (4 tubi) batteria di raffreddamento. Perdita di carico lato acqua e potenza frigorifera con varie portate d'acqua 20 potenza frigorifera in % della potenza nominale Qk 120 perdita di carico lato acqua ∆pw [kPa] 10 100 5 2 Gr. 1250 Gr. 1000 Gr. 800 Gr. 630 1 0,5 40 90 140 80 60 40 190 20 40 60 80 100 120 140 portata d’acqua in % rispetto alla portata nom. portata d’acqua w [kg/h] Induttore tipo HFB-Z (4 tubi) batteria di riscaldamento. Perdita di carico lato acqua e potenza calorifera con varie portate d'acqua 15 potenza calorifera in % della potenza nominale Qh 120 perdita di carico lato acqua ∆pw [kPa] 10 5 100 2 Gr. 1250 Gr. 1000 Gr. 800 Gr. 630 1 0,5 0,2 80 60 40 40 90 140 portata d’acqua w [kg/h] 190 20 40 60 80 100 120 portata d’acqua in % rispetto alla portata nom. E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 11 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB Montaggio La costruzione compatta consente il posizionamento dell’induttore tra i puntelli del pavimento rialzato. I piedini regolabili in altezza ne permettono il perfetto livellamento Uno dei due attacchi dell’aria primaria viene collegato a rete, l’altro viene tappato. Gli attacchi dell’acqua si trovano a sinistra nell’apposito spazio riservato al valvolame. I passaggi delle tubazioni idriche si possono prevedere a sinistra sulla parete retrostante. La griglia di ventilazione va posizionata a livello del pavimento finito ed è praticabile. Induttore da incasso a pavimento tipo HFB con griglia di ventilazione Procedimento - posizionamento dell’apparecchio con la striscia isolante direttamente a ridosso della facciata - livellamento mediante piedini regolabili in altezza - bloccaggio dei piedini, se necessario, con mastice adatto - taratura mediante serrandina e misurazione prevalenza aria primaria - posizionamento dei puntelli del pavimento e montaggio dei pannelli a contatto diretto con l’induttore - Installazione degli allacciamenti elettrici ed idrici. Gli allacciamenti idrici devono essere realizzati in modo flessibile e privi di tensioni. Esecuzioni speciali/accessori - Valvole di regolazione con servocomando proporzionale, termico o a tre punti - Tubi flessibili, con sistema di collegamento sicuro e rapido, completi di valvola di sfiato - Griglia di ventilazione praticabile trattata con polveri epossidiche oppure in alluminio o acciaio inox, con lamelle disposte in parallelo alla facciata. La griglia va semplicemente appoggiata dall’alto nell’apposita sede. Per l’impiego di griglie di altri produttori è necessario il benestare preventivo della LTG, per poter garantire il funzionamento perfetto del sistema. - Serrandina di taratura aria primaria per l’equilibratura delle portate; rapporto di regolazione 11,5 Regolazione La regolazione avviene sul lato acqua mediante valvole Manutenzione Tutte le componenti si trovano all’interno di una scatola in lamiera d’acciaio e sono facilmente accessibili dall’alto per operazioni d’ispezione, pulizia e manutenzione Induttore da incasso a pavimento tipo HFB montaggio tra puntelli del pavimento rialzato. E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 12 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB Esempio di installazione 1131 (HFB-- N 800) 33,5 17,5 Ponte distanziatore z. B. 250 441 187 1131 (HFB-- N 800) Esempio di installazione: griglia continua lungo la facciata Note per il montaggio in linea Qualora per motivi estetici sia richiesta una griglia continua lungo la facciata, i ventilconvettori saranno collegati tra loro mediante un ponte distanziatore in lamiera patinata colore nero. In presenza di distanze superiori a 400 mm e spezzoni terminali, è necessario prevedere dei puntelli di sostegno Griglia in acciaio inox A partire da una distanza di 600 mm, per motivi di stabilità è suggerito l’impiego di una vasca vuota. Con la griglia a nastro LTG si possono ottenere pezzi ad angolo e prevedere ritagli per pilastri. Capacità di carico delle griglie Le 3 varianti di griglie LTG calpestabili presentano i carichi statici seguenti: - Griglia in acciaio inox: - Griglia a nastro in alluminio - Griglia in alluminio Altri carichi dietro richiesta. Griglia a nastro in alluminio 1500 kg/m2 1600 kg/m2 2000 kg/m2 Griglia in alluminio E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 13 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore da incasso a pavimento tipo HFB Nomenclatura HFB - Z - 2 / 800 / 300 / 1198 / 1R / E / S scambiatore di calore a due file Z scambiatore di calore a tre file D 2 4 a 2 tubi a 4 tubi grandezza 630 800 1000 1250 larghezza griglia 300 lunghezza griglia con telaio aperto con telaio chiuso su 1 lato con telaio chiuso su 2 lati griglia: in acciaio inox a nastro in alluminio 20 mm in alluminio anodizzato corpo induttore patinato nero corpo induttore colore speciale OR 1R 2R E AR AE S SO E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 14 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore a pavimento tipo HFB - Specifica Quantità Specifica Prezzo unitario netto Prezzo totale netto Induttore per sistemi a 2 e a 4 tubi, per regolazione sull'acqua tramite valvole. Tipo HFB (riscaldamento e raffreddamento) Induttore da incasso a pavimento, con scambiatore multitubolare. Circuiti indipendenti per il riscaldamento ed il raffreddamento (sistema a 2 e a 4 tubi) composto da: - Carcassa a libera installazione in pavimento a cavità vuota o doppio pavimento, consistente in una vaschetta resistente a torsione in lamiera d’acciaio zincata, superficie rivestita, spessore lamiera 1,5 mm con margini laterali rinforzati, spessore lamiera 2,5 mm, per accogliere il carico statico elevato (RW > 25 dB). Con camera valvole separata e profili di appoggio per la griglia da pavimento a superficie frontale nonché isolamento antirumore e anticalpestio. - Griglia da pavimento in alluminio transitabile su tutta la lunghezza dell’apparecchio, larga 300 mm; funge da apertura d’ispezione, attraverso la quale tutti i componenti sono facilmente accessibili dall’alto per la manutenzione e la pulizia. - 4 piedini con isolazione anticalpestìo regolabili in altezza. - Fori di passaggio con spigoli protetti per il passaggio dei tubi di alimentazione, con tappi in plastica antirumore per i fori non utilizzati. - Scambiatore di calore unico con circuiti indipendenti per il riscaldamento ed il raffreddamento. Tubi di rame Ø 12 mm con pacco alettato in alluminio per altissimi rendimenti termici e convettivi, predisposti per collegamenti a sistema rapido. Pressione d’esercizio fino a 12 bar. - Camera valvole di regolazione posizionata sulla parte sinistra dell’apparecchio - Bocca premente a ridosso della facciata per una migliore schermatura della facciata. - Plenum di distribuzione aria primaria con ugelli sintetici estraibili, per alti rapporti induttivi, basso livello acustico e altissimo coefficiente di riflessione acustica del rumore primario Dimensioni esterne profondità x altezza = 308 (441) mm x 191 mm (griglia in alluminio) (le dimensioni possono variare a seconda delle versioni) Grandezze: o 630 o 800 o 1000 o 1250 E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 15 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore a pavimento tipo HFB - Specifica Quantità Specifica Prezzo unitario netto Prezzo totale netto - 2-Versioni: - Valvola a farfalla KLI, integrata nel collegamento aria pura. - Utilizzo diffusione di dislocamento e di miscelazione MQ. Utilizzo ventaglio per una migliore diffusione nel locale, integrato nella sezione bocca premente per la produzione di una diffusione combinata di miscelazione e dislocamento nel caso di bassa velocità dell’aria, per grandi prestazioni di raffreddamento e bassa stratificazione della temperatura nella zona di permanenza. - Griglia in acciaio inox - Griglia a nastro in alluminio - Preparata per montaggio continuo. Parete laterale ridotta per accogliere una lamiera di collegamento per griglia ad ottica continua Accessori / Esecuzione speciale: Accessori / Equipaggiamento speciale: - 2 tubi flessibili (anima in EPDM) con calza in acciaio inox, attacco ad innesto rapido su un lato e attacco a scelta sul lato opposto, lunghezza: 500 mm senza isolamento per il raccordo alla rete acqua calda - 2 tubi flessibili (anima in EPDM) con calza in acciaio inox, attacco ad innesto rapido su un lato e attacco a scelta sul lato opposto, lunghezza: 500 mm senza isolamento per il raccordo alla rete acqua calda nella versione a densa diffusione di ossigeno - 2 tubi flessibili (anima in EPDM) con calza in acciaio inox, attacco ad innesto rapido su un lato e attacco a scelta sul lato opposto, lunghezza: 500 mm coibentati per il raccordo alla rete acqua refrigerata - 2 tubi flessibili (anima in EPDM) con calza in acciaio inox, attacco ad innesto rapido su un lato e attacco a scelta sul lato opposto, lunghezza: 500 mm coibentati per il raccordo alla rete acqua refrigerata nella versione a densa diffusione di ossigeno - 2 microvalvole con servocomando termoelettrico - 2 microvalvole con azionamento a 3 punti - Collegamenti scambiatore di calore con filettatura interna 1/2“ per l’accoppiamento diretto delle valvole - 3-- E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 16 L’Azienda dell’Innovazione LTG Aktiengesellschaft Induttore a pavimento tipo HFB - Specifica Quantità Specifica tecnica Prezzo netto unitario in Prezzo netto totale in - 3-Dati tecnici Pressione aria primaria Portata aria primaria Livello di potenza sonora LWA Livello di pressione sonora con 18 m2 Sabine LpA [Pa] [m3/h] [dB(A)] [dB(A)] Raffreddamento Temperatura aria aspirata Temperatura aria primaria Temperatura acqua di mandata Potenza frigorifera [_C] [_C] [_C] [W] Riscaldamento Temperatura aria aspirata Temperatura acqua di mandata Potenza calorifera [_C] [_C] [W] Convezione naturale [W] Produttore: LTG Aktiengesellschaft Serie: Induttore a pavimento Tipo: HFB E LTG Aktiengesellschaft ⋅ Grenzstraße 7 ⋅ D-70435 Stuttgart ⋅ +49 (0711) 8201-180 ⋅ Fax -720 Bodenind-I-TP (09/07) Internet: http://www.LTG-AG.de ⋅ E-Mail: [email protected] ⋅ Printed in Germany ⋅ Ausgaben mit früherem Datum werden hiermit ungültig ⋅ Technische Änderungen vorbehalten ⋅ Former editions are invalid ⋅ Subject to technical modifications. 17