www.zetaqlab.com RF-D110 Wireless control module for DALI and 1/10V standard driver Modulo di controllo wireless per driver standard DALI ed 1/10V RF-D110 manages one single lighting fixture with DALI or 1/10V standard driver(s) using wireless commands. The module provides to driver(s) control signal and power. Light Group of the fixture can be selected by means of a rotary switch and/or via software. RF-D110 can interfaces analog and digital signals from sensors like movement, light and temperature. RF-D110 can be installed inside or outside luminaires and the antenna could be integrated (wired) or external, connected by standard SMA connector. RF-D110 gestisce via wireless un singolo apparecchio d’illuminazione dotato di uno o più driver standard DALI o 1/10V. Il modulo fornisce al/ai driver il segnale di controllo e l’alimentazione. Il Light Group dell’apparecchio può essere impostato tramite il selettore rotativo e/o tramite software. RF-D110 può interfacciare segnali proveninenti da sensori analogici e digitali come movimento, luminosità e temperatura. RF-D110 può essere installato all’interno degli apparecchi oppure alloggiato esternamente. L’antenna può essere integrata (filare) oppure esterna, collegata tramite connettore SMA. Features Caratteristiche • Controls up to 4 1/10V or DALI standard driver • Controlla fino a 4 driver standard 1/10V o DALI • 500 VA relè for driver power supply control • Controllo in potenza dei driver tramite relè da 500VA • Normally closed relè for safe operation in failure • Relè normalmente chiuso per sicurezza in avaria • Double insulation (power and dimming) • Doppio isolamento elettrico (alimentazione e regolazione) • Suitable for LED and traditional sources • Adatto per sorgenti LED e tradizionali • Rotary switch for Light Group setting • Selettore per impostazione manuale del Light Group • External (SMA) or integrated (wired) antenna • Antenna esterna (SMA) oppure integrata (filare) • Module diagnostics LEDs • LED per la diagnostica del modulo • 1/10V or DALI dimming output selector • Selettore uscita di regolazione 1/10V oppure DALI • 3 digitali input/1 analog input for external sensors • 3 ingressi digitali/1 analogico per sensori esterni • Transmission on ISM 868 MHz band • Trasmissione nella banda ISM a 868 MHz • 915 MHz version available on request • Versione 915 MHz disponibile su richiesta • Wide range and high noise immunity • Ampia portata ed alta immunità ai disturbi • Mesh Network for radio range extension • Mesh Network per estensione della portata radio • Data encryption for communication with the Server • Crittografia dei dati scambiati con il Server • IP54 version for installation outside lighting fixtures • Versione IP54 per installazione esterna agli apparecchi Hardware & Software Engineering Via E. Borgazzi 51, 20823 Lentate sul Seveso (MB) Italy www.zetaqlab.com RF-D110 datasheet Rev. 13/02/2015 Specifications subject to change without notice 1 31 mm www.zetaqlab.com Dimensions / Dimensioni RF-D110 / RF-D110-SMA 103 mm 94 mm 31 mm 67 mm 58 mm 83,5 mm RF-D110 3 4 5 7 F 0 1 2 6 A B E 8 9 C D 41 mm 103 mm 103 mm 83,5 mm RF-D110 3 4 5 6 F 0 1 C D 41 mm B E A 31 mm 8 9 63 mm 7 82 mm 2 123 mm 67 mm 134 mm 58 mm RF-D110-IP54 94 mm 103 mm 134 mm 103 mm 123 mm RF-D110-SMA: Antenna connector (SMA female) Connettore antenna (SMA femmina) 3 4 5 7 F 0 1 2 6 8 9 A E Power output Alimentazione driver Nin Lin Power input Alimentazione modulo 67 mm RF-D110 B 58 mm Sensors connector Connettore sensori Lout Nout DALI RF Power 63 mm 82 mm Connections / Connessioni 94 mm Light Group selector Selettore Light Group Diagnostic LED LED diagnostica C D + (DALI) Control output - (DALI) Segnale di controllo Control type selector Selettore segnale di controllo 103 mm Hardware & Software Engineering Via E. Borgazzi 51, 20823 Lentate sul Seveso (MB) Italy www.zetaqlab.com RF-D110 datasheet Rev. 13/02/2015 Specifications subject to change without notice 2 www.zetaqlab.com Drivers connection / Collegamento dei driver For 1/10V drivers switch on/off has obtained by means of power cable from Nout and Lout connectors. For DALI drivers switch on/off has obtained also with the only DALI signal. Per ottenere l’ accensione/spegnimento di driver 1/10V è necessario collegare l’alimentazione in uscita Nout ed Lout. Per driver DALI l’ accensione/spegnimento si può ottenere anche dal solo segnale DALI. L N Lout Nout Nin Lin RF-D110 + (DALI) - (DALI) L N LED driver dimmable 1/10V or DALI + (DALI) - (DALI) ATTENTION: power out for drivers is limited at 500 VA ATTENZIONE: la potenza fornita ai driver è limitata a 500 VA Max 4 drivers in parallel Massimo 4 driver in parallelo 3-pole cable: power input (Line, Neutral, PE) Cavo tripolare: alimentazione (Linea, Neutro, Terra) Lighting fixture RF-D110-IP54 dimmable 1/10V or DALI 5-pole cable: power output (Line, Neutral, PE) and dimming (DA,DA or +,-) Cavo pentapolare: alimentazione (Linea, Neutro, Terra) e regolazione (DA,DA oppure +,-) Sensors / Sensori 1 Digital Input 1 2 Digital Input 2 3 Digital Input 3 4 Analog Input 1 5 GND 6 GND 7 +12 Vdc 8 +12 Vdc External sensors connection RF-D110 has 3 digital input (Open Collector or Dry Contact) and 1 analog input (0-3,3V) for external sensors (movement, light, temperature, etc.) and for others signals. Connector block model TYCO MODU II. Connessione sensori esterni RF-D110 dispone di 3 ingressi digitali Open Collector o contatto pulito ed 1 ingresso analogico 0-3,3V per la connessione di sensori esterni (movimento, luminosità , temperatura, ecc.) oppure di altri segnali. Connettore modello TYCO MODU II. Hardware & Software Engineering Via E. Borgazzi 51, 20823 Lentate sul Seveso (MB) Italy www.zetaqlab.com RF-D110 datasheet Rev. 13/02/2015 Specifications subject to change without notice 3 www.zetaqlab.com Control signal / Segnale di regolazione 1/10V PIN 1+2 1 2 Select the jumper beside + (DALI) and - (DALI) connectors in order to set the control signal to analog 1/10V or digital DALI. Swicth off the device before make change. 1 DALI PIN 2+3 2 3 3 Impostare il jumper accanto ai morsetti + (DALI) e - (DALI) per selezione il di segnale di regolazione su analogico 1/10V oppure digitale DALI. Eseguire le modifiche a dispositivo spento. Light Group selection / Selezione del Light Group Light Group 0 LG 1 8 LG 9 1 LG 2 9 LG 10 2 LG 3 A LG 11 3 LG 4 B LG 12 C LG 13 D LG 14 6 LG 7 E LG 15 7 LG 8 F LG 16 34 5 7 8 9A LG 5 LG 6 I moduli RF-D110 possono essere suddivisi in 16 gruppi funzionali (Light Group) tramite il selettore hardware oppure via software (tramite il Server). Eseguire le modifiche a dispositivo spento. 6 4 5 RF-D110 modules can be devided into 16 functional groups (Light Group) by the hardware selector or via software (from the Server). Swicth off the device before make change. F0 1 2 Value E Light Group BCD Light Group (LG) Value WARNING / ATTENZIONE LG1 group corresponds to the 0 (zero) on the rotary switch and so on. Il gruppo LG1 corrisponde al valore 0 (zero) del selettore e così via. Technical data / Specifiche tecniche Input power Mains 110-240Vac 50-60 Hz Max load 500VA Power consumption max 3W Radio Frequency Frequency band 868 MHz (915 on request) Radio Ouput Power +13 dBm LBT and AFA supported Transmission range 300 m Open Field (Whip Antenna) Extension by Mesh Network up to 3 Km Relay output Normally closed Max switched current 3A Max switched load 500VA Dimming output Analog 1/10V: max 4 driver Digital DALI: max 4 driver GPIO n.1 Rotary switch for Light Group settings n.3 Digital Input (Dry Contact) n.1 Analog Input (0-3,3Vdc) Diagnostic LED n. 3 LED (Power, RF and DALI) Connector block Wago 250 push in Wire cross section AWG16 (1.3 mm2) SMA female for antenna (option) GPIO model TYCO MODU II MTBF 50.000 Hours Input-output insulation 6 kV Operating Environment Ambient temperature (ta) -20°C to +65°C Relative humidity 10% to 90% Max. housing temp. (tc) 80°C Storage -30°C to +80°C Housing Plastic IP20 or IP54 Dimension & Weight See diagram for details 0,1 Kg Standards & Legislation Approvals R&TTE directive 1999/5/EC EMC directive 2004/108/EC LV directive 2006/95/EC RoHS directive 2002/95/EC REACH directive 2006/1907/EC Safety EN61347-2-11 EMC EN61000, EN55015, ETSI EN 300-220-2 ETSI EN 301-489-1, 301-489-3 Ordering data / Codici d’ordine Model / Modello Description / Descrizione RF-D110 RF-D110, IP20 box, integrated antenna / RF-D110, box IP20, antenna integrata RF-D110-SMA RF-D110, IP20 box, SMA connetcor for external antenna / RF-D110, box IP20, connettore SMA per antenna esterna RF-D110-IP54 RF-D110, IP54 box, integrated antenna / RF-D110, box IP54, antenna integrata For further informations about models and accessories available: www.zetaqlab.com Per ulteriori informazioni sui modelli disponibili e sugli accessori: www.zetaqlab.com Hardware & Software Engineering Via E. Borgazzi 51, 20823 Lentate sul Seveso (MB) Italy www.zetaqlab.com RF-D110 datasheet Rev. 13/02/2015 Specifications subject to change without notice 4