Nr. 2013/1.10/32 Data: 26.07.13 PLC: SIMATIC S7-1500 più TIA Portal V12 SP 1 Il TIA Portal V12 Service Pack 1 è rilasciato e pronto per fare un download (Le informazioni esistono ancora solo in tedesco) Condizione: La versione TIA Portal V12 deve essere installata e l’utente deve aggiornare tutti i software, non può aggiornare soltanto un software! STEP 7 V12 SP1: Informazione: http://support.automation.siemens.com/WW/view/de/76276623 Download: http://support.automation.siemens.com/WW/view/de/75277515 WinCC V12 SP1: Informazione: http://support.automation.siemens.com/WW/view/de/73947391 Download: http://support.automation.siemens.com/WW/view/de/73956248 STARTDRIVE V12 SP1: Informazione: http://support.automation.siemens.com/WW/view/de/77330014 Download: http://support.automation.siemens.com/WW/view/de/68034568 TIA Selection Tool Offline Version: www.siemens.com/tia-selection-tool Online Version (JAVA): https://eb.automation.siemens.com/mall/it/it/Catalog/Configurators Tutorial: https://www.automation.siemens.com/mcms/topics/en/simatic/tia-selectiontool/Pages/tab.aspx?tabcardname=Tutorials# TIA PORTAL V12 SP 1 http://support.automation.siemens.com/WW/view/en/67639464 1. STEP 7 TIA PORTAL V12 SP 1 2. WinCC TIA Portal V12 SP 1 Restricted © Siemens AG 2013 All rights reserved. siemens.com/answers TIA Portal V12 SP 1 Informazione generale Performance è migliorata Stabilità ancora è okay Download gratuito sul Service&Support dal 24.07 Compatibilità Progetto V11 in V12 SP 1 Installazione del SP 1 possibile in parallele con STEP 7 Classico, TIA Portal V10.5 o V11 NON V12 Release of V12 SP1 / SUS delivery Compatibility mode V11 Compatibility mode V11 can be used in V12 SP1 (same as in V12). Projects of V11 can be opened/engineered/stored with TIA Portal V12 SP1. After engineering with V12 SP1 the project can be used in TIA Portal V11 SP2. • Dal 26 luglio nuove ordine verrà consegnato con V12 SP1 I contratti SUS riceveranno fra 4 settimane I DVD con SP 1 • STEP 7 SUS verrà consegnato prima e compresa Startdrive AND WinCC Comfort/Advanced DVD • Clienti riceverà WinCC due volte, se hanno anche Restricted © Siemens AG 2013 All rights reserved. un WinCC SUS contratto Page 2 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 Orazio Vinci Supporto Tecnico S7-300/400/DP S7-1500 SCL TIA Portal STEP 7 STEP 7 TIA PORTAL V12 SP 1 http://support.automation.siemens.com/WW/view/en/67639464 Restricted © Siemens AG 2013 All rights reserved. siemens.com/answers Compatibility of V12 SP1 - projects and devices Upgrade V12 -> V12 SP1 Compatibility at Upgrade V12 to V12 SP1 • No compatible repository of V12 and V12 SP1 projects due to new features • Projects opened in V12 SP1, can’t be edited with V12 anymore • When opening a V12 project with TIA Portal V12 SP1 the user will be advised to upgrade the project • The original V12 project is still available in parallel • Details HMI • Panels and RT Advanced remain the configured runtime version (V11 or V12) at project upgrade (ES) • Runtime Professional will upgraded automatically to V12 SP1 at project upgrade (ES) • WinCC V12 SP1 allows editing of devices in the runtime versions V11 and V12 • The configured runtime version activate the available functionality of the devices • Version changes (V11 V12) will be done by “Change device/version…” • Details PLC • Engineered V11/V12 PLCs can be opened with STEP 7 V12 SP1 • Engineered V12 SP1 PLCs (S7-300, S7-400) can be opened with STEP 7 V12 • Engineered V12 SP1 PLCs (S7-1200, S7-1500) can’t be opened with STEP 7 V12 • In the live list V12 all contents (e.g. blocks) with V12 SP1 engineered PLC’s will be marked with a prohibition sign (e.g. opening of a block not possible) Restricted © Siemens AG 2013 All rights reserved. Page 4 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 Download of project PLC Engineering V11 ES V12 ES V12 SP1 V11 project V11 project V12 project (compatible) S7-1200 S7-300 S7-400 V11 project (compatible) S7-1500 V1.0 V12 SP1 project S7-1500 V1.1 PLC Restricted © Siemens AG 2013 All rights reserved. Page 5 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 Download di progetti nel runtime HMI Panel Engineering V11 ES V11 project V12 ES V11 project V12 SP1 ES V11 project V12 project (compatible) (compatible) HMI V11 Version HMI V11 Version HMI V11 HMI V11 Version HMI V12 Version HMI V12 HMI V11 Version V12 SP1 project HMI V11 Version HMI V12 Version HMI V12 SP1 Version HMI V12 SP1 HMI Runtime Restricted © Siemens AG 2013 All rights reserved. Page 6 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 CAMBIO FW A V11 I IA AS Milano – Team TIA Portal V12 Download di progetti nel runtime HMI Panel Engineering V11 ES V11 project V12 ES V11 project V12 SP1 ES V11 project V12 project (compatible) (compatible) HMI V11 Version HMI V11 Version HMI V11 HMI V11 Version HMI V12 Version HMI V12 HMI V11 Version V12 SP1 project HMI V11 Version HMI V12 Version HMI V12 SP1 Version HMI V12 SP1 HMI Runtime Restricted © Siemens AG 2013 All rights reserved. Page 7 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 CAMBIO FW A V11 I IA AS Milano – Team TIA Portal V12 Download di progetti nel runtime HMI Panel Engineering V11 ES V11 project V12 ES V11 project V12 SP1 ES V11 project V12 project (compatible) (compatible) HMI V11 Version HMI V11 Version HMI V11 HMI V11 Version HMI V12 Version HMI V12 HMI V11 Version V12 SP1 project HMI V11 Version HMI V12 Version HMI V12 SP1 Version HMI V12 SP1 HMI Runtime Restricted © Siemens AG 2013 All rights reserved. Page 8 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 CAMBIO FW A V12 I IA AS Milano – Team TIA Portal V12 Download di progetti nel runtime HMI Panel Engineering V11 ES V11 project V12 ES V11 project V12 SP1 ES V11 project V12 project (compatible) (compatible) HMI V11 Version HMI V11 Version HMI V11 HMI V11 Version HMI V12 Version HMI V12 HMI V11 Version V12 SP1 project HMI V11 Version HMI V12 Version HMI V12 SP1 Version HMI V12 SP1 HMI Runtime Restricted © Siemens AG 2013 All rights reserved. Page 9 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 CAMBIO FW A V12 SP1 I IA AS Milano – Team TIA Portal V12 STEP 7 Language Innovations S7-Graph + Availability of S7-Graph with S7-1500 too S7-1500 CPU Add FB Select GRAPH Restricted © Siemens AG 2013 All rights reserved. Page 10 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 STEP 7 Language Innovations New Instruction - MB_CLIENT / MB_SERVER + Communication via MODUBS TCP • S7-1500 can communicate in Modbus TCP with blocks inside the library ‘Communication’ • The library is free of charge (without licence) and yet available inside the library of TIA Portal V12 SP1 Restricted © Siemens AG 2013 All rights reserved. Page 11 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 S7-PLCSIM Simulation S7-1500 + Simulation of S7-1500 PLC-functionality with Look & Feel of the TIA-Portal NEW in SP1: Simulation of PID Professional and Failsafe Communication between PLCSIM-Instances with the following instructions: - PUT/GET - BSend/Brcv - Master-Master Communication to local WinCC Runtime Restricted © Siemens AG 2013 All rights reserved. Page 12 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 System Usability Reinitialize DB + Simplified and fast commissioning 1. Define setpoint Easy optimization of parameters during commissioning: • The start value for the set points can be taken over to the working memory as actual value directly. 2. Snapshot of actual values 3 2 4 3. Apply snapshot values for setpoints as start values 4. Apply start values to the working memory of the PLC as actual value Restricted © Siemens AG 2013 All rights reserved. Page 13 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 STEP 7 Language Innovations User defined data type on I/O + Structured and symbolic access on I/O Define user defined data types for in- and outputs: Reference structured in- or outputs as a user defined data type. For example to send and receive telegrams for drive. 1. Define user defined type (UDT) 3. Use I/O 2. Reference tag with UDT to an in- or output Restricted © Siemens AG 2013 All rights reserved. Page 14 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 System Usability Simplified block view + Fast overview for the whole PLC-program • Possibility to have a detailed view of all blocks in the PLC without folder division. Restricted © Siemens AG 2013 All rights reserved. Page 15 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 System Usability Advanced possibilities to navigate within blocks + Simple navigation within the code • New functionality in cross reference: • New functionality: “Go to read/write access” Restricted © Siemens AG 2013 All rights reserved. Page 16 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 Daniela Amigoni PM WinCC Advan., Panels TIA Portal WinCC WinCC TIA PORTAL V12 SP 1 http://support.automation.siemens.com/WW/view/en/67639464 Restricted © Siemens AG 2013 All rights reserved. siemens.com/answers Mobile Panel 277(F) IWLAN in WinCC V12 SP1 Highlights Support of Mobile Panel 277F IWLAN Support of F-FBs in global library (S7-300F and S7-400F) Configuration of F-functionality requires Safety Advanced V12 (sett 2013) Easy installation of F-FBs using CD delivered with Mobile Panel 277F IWLAN Restricted © Siemens AG 2013 All rights reserved. Page 18 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC WinCC V12 SP1 Diagnosis service System diagnosis viewer • Overview of accessible devices and status information of the plant • Switch between device and detail view • Common concept for Comfort Panels, RT Advanced, RT Professional, CPU Display & CPU web server • View is also available for Basic Panels New with SP1 Restricted © Siemens AG 2013 All rights reserved. Page 19 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC WinCC V12 SP1 Diagnosis service STEP 7 HMI HMI Web server CPU-Display Restricted © Siemens AG 2013 All rights reserved. Page 20 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC WinCC V12 SP1 Download WinCC Runtime Professional - Extension of Offline-Download Offline Download Dialog Selectable whether • logging • alarms • recipes shall be overwritten on the target device. Restricted © Siemens AG 2013 All rights reserved. Page 21 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC HMI Comfort Panels Use of existing projects - Easy Migration into TIA Portal Scenario 1: Changeover of engineering system to TIA Portal PLC and HMI in TIA Portal Scenario 2: Changeover to WinCC (TIA Portal) Mixed configuration: PLC in STEP7 5.5, HMI in WinCC (TIA Portal) TIA Portal TIA Portal WinCC flexible WinCC V1x 2. WinCC flexible WinCC V1x 1. WinCC V1x 2. WinCC V1x 1. STEP7 V5.5 STEP7 V1x STEP7 V5.5 S7-300/400 S7-300/400 S7-300/400 1. Migration of integrated project via „Migrate project “ 1. Process communication Migration of WinCC flexible project via „Migrate project “ Convert of project in TIA Portal project. Convert of project in TIA Portal project. Original panel is kept. Original panel is kept. 2. Device change „Change device/version“ at the push of a button 2. Device change „Change device/version“ at the push of a button Change of original panel to successor Change of original panel to successor All data are kept (screens, connections,…) All data are kept (screens, connections,…) Restricted © Siemens AG 2013 All rights reserved. Page 22 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC HMI Comfort Panels Mixed configuration - extension of the STEP 7 project after migration Scenario 3: Synchronization after changes in STEP 7 Classic Mixed configuration: PLC in STEP7 5.5, HMI in WinCC (TIA Portal) TIA Portal WinCC flexible 1. WinCC V1x 2. WinCC V1x STEP7 V5.5 S7-300/400 Changed addresses Synchronization via TagConverter When it makes sense to use the TagConverter? Mixed configuration: STEP 7 Classic and WinCC (TIA Portal) after migration of a WinCC flexible projects and extension of the STEP 7 project. •The TagConverter can be used while engineering after migration. Using the TagConverter it is easy to synchronize tag configuration data in engineering, if the addresses were changed in STEP 7 or if the STEP 7 project was extended. •The TagConverter is not necessary for process communication in runtime. •The TagConverter is not necessary for migration. Restricted © Siemens AG 2013 All rights reserved. Page 23 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC HMI Comfort Panels Mixed configuration - new projects Scenario 4: Engineering of new HMI projects Mixed configuration: PLC in STEP7 5.5, new HMI in WinCC (TIA Portal) 1. STEP 7 V5.5 S7-300/400 Process communication possible Synchronization of data while engineering 3. 2. TIA Portal When it makes sense to use the TagConverter? Mixed configuration: STEP 7 Classic and WinCC (TIA Portal) and creation of a new project WinCC V1x 4. 1. Programming of PLC with STEP7 V5.5 2. Creating a new project with WinCC (TIA Portal). •With the TagConverter tag lists and symbols can be read from STEP 7 Classic and imported in WinCC (TIA Portal). Engineering is easy. •The TagConverter can be used while engineering. Using the TagConverter it is easy to synchronize tag configuration data in engineering. No address data of PLC in HMI 3. Converting of tags/symbols of STEP7 V5.5 via TagConverter. 4. Import of the file of TagConverter in the tag table of the panel in •The TagConverter is not necessary for process communication in runtime. WinCC (TIA Portal) Restricted © Siemens AG 2013 All rights reserved. Page 24 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC HMI Comfort Panels Collaboration STEP 7 Classic and WinCC (TIA Portal) Step 2 Step 1 Sept. 2013 Today S7 Classic Project S7 Classic Project Tag Converter export of DBs using Tags only text printer Export of DBs using Tag Converter TagConverter S7 Classic Project XLSX Files XLSX File Tags only Collaboration STEP 7 Classic and WinCC (TIA Portal) full integration – no restrictions TIA Portal V11/12 TIA Portal V11/12 TIA Portal V13 • September 2013 improvement of usability of TagConverter • WinCC V13 Collaboration of STEP 7 Classic and WinCC (TIA Portal) • Data blocks and symbols Restricted © Siemens AG 2013 All rights reserved. Page 25 • Integration: Alarm_S andTIA RSE 2013 – LIVE MEETING – TRAINING PORTAL V12 I IA AS Milano – Team TIA Portal V12 SIMATIC HMI Comfort Panels New and improved TagConverter 09/2013 Functionality •New TagConverter can export the DBs and symbols directly from the STEP 7 Classic Projekt. •No need to export each DB using the text printer. •Several DBs can be converted at the same time. •Not all tags have to be converted, HMI relevant tags can be selected. •One single file has to be imported in Tia Portal which contains all relevant tags and symbols. Conversion of tags and symbols only. ALARM_S and ReportSystemError not possible. Restricted © Siemens AG 2013 All rights reserved. Page 26 2013 – LIVE MEETING – TRAINING TIA PORTAL V12 I IA AS Milano – Team TIA Portal V12