Trasformatori in olio distribuzione ed esecuzioni speciali MADE IN ITALY www.gbeonline.com Oil filled transformers for distribution and special applications 2 A dynamic and efficient team Una Realtà Dinamica ed efficiente ENG In a continuously expanding and developing world where it is required to be competitive and dynamic in every market, the company shall give evidence of its skills providing constantly state of art products that fulfils the markets’ request. Being in the business as we put it here in GBE does not lie as much in waiting for replies from the market, but rather in proposing themselves, understanding the demands, evaluating the needs and at the customers’ side offering more than required by constantly calling themselves into question so to increase and improve. GBE desire to show how not only the Italian Design but also the Italian Technology could be appreciated worldwide as long as the demand is seriously dealt with commitment and maximum availability to work as a great one-team. Mission In un mondo in continua espansione e sviluppo dove in ogni mercato si deve essere competitivi e dinamici, l’azienda deve dar prova e dimostrazione delle proprie capacità proponendo un prodotto sempre nuovo e che soddisfi pienamente le richieste del mercato. Fare impresa così come lo intendiamo in GBE, non significa tanto attendere risposte dal mercato, quanto proporsi, capire le esigenze, valutare le necessità e, sempre dalla parte del cliente, offrire più di quanto richiesto, mettendosi continuamente in discussione per poter crescere e migliorare. GBE desidera dimostrare come non solo il design ma anche la tecnologia italiana possa essere apprezzata in tutto il mondo, qualora la richiesta sia affrontata con serietà, impegno e massima disponibilità di un team unito. GBE S.p.A. is specialized in manufacturing of oil filled transformers from 50 kVA up to 50 MVA, 145 kV (BIL 650 kV). Furthermore we offer oil filled reactors from few kVAR up to 10 MVAR. Our experience in the field has enabled us to solve a wide range of requirements even for special units, i.e. converter transformers with 6-12-18-24-36 pulse, earthling transformers with and without auxiliaries, transformers for solar plants with 1-2-3 secondary windings, HV/HV transformers, multi voltage transformers, transformers with different type of oil: Silicon type, MIDEL, FR3. Shunt reactors, current limiting, damping, tuning (filter), arc-suppression, smoothing reactors, LV/MV/HV reactors up to 52 kV. GBE S.p.A. are present in the national and international market and count on a 25-year technical experience in the field. The recently built new works are equipped with high-tech producing plants, the most sophisticated automation job order systems via real time production management. ENG ITA ITA La GBE S.p.A. è specializzata nella produzione di trasformatori in olio da 50 kVA fino a 50 MVA, 145 kVA (BIL 650 kV). Inoltre produce reattanze in olio da alcuni kVAR fino a 10 MVAR. L'esperienza acquisita ci ha permesso finora di risolvere le più svariate richieste anche per unità speciali quali: trasformatori per impianti di conversione a 6-12-18-24-36 pulse, trasformatori di messa a terra con e senza ausiliare, trasformatori per impianti solari con 1-2-3 secondari, trasformatori MT/MT, trasformatori multitensione, Trasformatori con olio siliconico; MIDEL o FR3. Reattori in olio di corto circuito, limitatrici, spianatrici, filtri, reattori di bassa, media e alta tensione fino a 52 kV. GBE opera direttamente sul mercato nazionale ed estero e si avvale di 25 anni di esperienza tecnica nel settore. Lo stabilimento di recente costruzione è munito di tutte le attrezzature e macchinari più sofisticati, con processi produttivi automatizzati ed una gestione della produzione in tempo reale tramite codifica delle commesse e bar-code per i materiali. 3 Magnetic core ENG ITA Nucleo magnetico 4 Il nucleo dei trasformatori GBE è costruito con lamierino magnetico a grani orientati ad alta permeabilità magnetica e a perdite specifiche isolati in ambo i lati da un sottile spessore di materiale inorganico (Carlyte). Il taglio e la composizione è del tipo a 45° a giunti intercalati con metodo “Step-Lap” in modo da ridurre le perdite a vuoto, la corrente a vuoto e la rumorosità del trasformatore. Il numero di gradini e il valore di induzione sono ottimizzati in funzione della potenza del trasformatore. Il serraggio è ottenuto da profili in acciaio zincato opportunamente dimensionati in grado di garantire robustezza e staticità adeguate per tutte le sollecitazioni derivanti dalle operazioni di trasporto e scarico, dagli sforzi elettrodinamici e dalle installazioni più difficili. GBE transformers cores are obtained from cold rolled grain oriented (CRGO) magnetic steel sheets with highly magnetic permeability and insulated on both sides with a thin layer of inorganic material (Carlyte). The sheet cut and the composition at 45° with “Step Lap” intercalated joints guarantee reduced no-load losses, reduced idling current and low noise level. The number of steps and the magnetic induction are optimized for the power of the transformer. The top and bottom clamps are made by galvanized steel designed as to guarantee the necessary strength for all movements during transport and unloading, electro dynamic stresses and the most difficult installations. Oil filled transformers GBE S.p.A. produce oil filled transformers for different applications, particularly for distribution and special apply with the power up to 50 MVA, also with unload tap changer. The transformer windings are concentric and coaxial to the core limbs. The windings are made of copper or aluminum with insulation material in class A or F. Channels in the windings guarantee oil circulation and windings optimal cooling. All transformers up to 3150 kVA are equipped with corrugated tank wall panels. Higher power units use special developed radiators made with cold rolled and laminated steel. All transformers up to 3150 kVA can be filled without conservator. The outside walls are protected with water resistant paint RAL 7031 or RAL 7033 with painting thickness of minimum 100 micron. Furthermore GBE S.p.A. offer customized tanks in request. Trasformatori in olio ENG ITA GBE S.p.A. produce trasformatori in olio per tutte le applicazioni, in particolare trasformatori per la distribuzione e speciali con potenza fino a 50 MVA, anche con commutatore sotto carico.Gli avvolgimenti dei trasformatori sono coassiali alle colonne del nucleo e di tipo concentrico. Possono essere realizzati in rame o alluminio con isolamento in classe A o F. Gli avvolgimenti possono presentare dei canali per la circolazione del olio e quindi raffreddamento degli stessi. Questi avvolgimenti sono a sezione ovale o circolare e del tipo concentrico, coassiali alle colonne del nucleo. La cassa dei trasformatori fino a 3150 kVA e del tipo a onde elastiche. Per potenze superiori sono previsti radiatori in lamiera stampata e laminata a freddo. Se previsto i trasformatori sono dotati di normale conservatore per l’espansione dell’olio. La cassa é protetta dalla vernice idrosolubile RAL 7031 o RAL 7033 con spessore di verniciatura 100-120 micron. Inoltre la GBE S.p.A offre casse personalizzate su richiesta. Informazioni generali Tutta la produzione è realizzata in conformità alle norme di riferimento europeo CEI, IEC, CENELEC, DIN, BRITISH STANDARD, UNI EN, ISO ed altre. Diverse sono le omologazioni e le certificazioni di prodotto ottenute fino ad ora: RINA, DNV, Lloyd's Register e altri. La GBE è certificata ISO 9001:2008 e ISO 14001. ENG ITA General information The whole GBE production is manufactured according to European Standards CEI, IEC, CENELEC, DIN, BRITISH STANDARD, UNI EN, ISO and more. Various are GBE recognitions and certifications such as RINA, DNV, LLOYD'S REGISTER and other naval and marine recognitions. GBE S.p.A. is ISO 9001:2008 and ISO 14001 certified. 5 ENG ITA Technical characteristics Caratteristiche tecniche 6 Accessori del trasformatore Transformer Accessories 1 Morsetti di Terra 2 Isolatori di Bassa Tensione 3 Commutatore regolazione 4 Tubo riempimento olio con valvola antiscoppio 5 Marshaling Box (su richiesta) 6 Tappo riempimento 7 Conservatore (se non è ermetico) 8 Relè Buchholz 9 Termometro a due contatti elettrici (su richiesta) 10 Golfari di sollevamento 11 Pozzetto termometrico 12Carrello 13 Avvolgimento di media tensione 14 Ruote orientabili ortogonalmente 15Nucleo 16 Valvola di scarico 17 Avvolgimenti di Bassa Tensione 18 Tappi di pressaggio 19Serrapacchi 20 Indicatore del livello olio (se non ermetico) 21 Isolatori di Media Tensione 22 Silicagel (se non è ermetico) 23 Cassa a onde 24 Attacchi Elastimold (su richiesta) 25 Massa sulla cassa 26 Targa con dati tecnici 27 Golfari di traslazione 1 Earthing terminals 2 Low Voltage Bushings 3 Off load tap changer 4 Filling pipe with antibrust valve 5 Marshaling Box 6 Filling tap 7 Conservator (if not hermetic) 8 Rele’ Buchholz 9 Thermometer with two electric contacts (upon request) 10 Lifting eyebolts 11 Thermometer pocket 12Truck 13 Medium Voltage Windings 14 Swivelling rollers 15 Magnetic Core 16 Oil discharge and extraction valve 17 Low Voltage Windings 18 Pressing Plugs 19Clamps 20 Oil level indicator (if not hermetic) 21 Medium Voltage Bushings 22 Silica gel connection (if not hermetic) 23 Tank with waves 24 Elastimold (upon request) 25 Earthing point on tank 26 Name plate 27 Movement eyebolts Accessori di Corredo su richiesta Further Accessories available upon request • • • • • • • • • DGPT2 o RIS (se ermetico) • Barre passanti per la Bassa Tensione • Valvola antiscopio con contatti • Immagine termica • Cable box per la bassa e media tensione • Oil level indicator with contacts (se non ermetico) • Sonde PT100 per il controllo della temperature di olio (PTO) • Scaricatori a corno • Altri (vedi costruttore) • DGPT2 or RIS (if airtight) LV extension bars Antibrust valve with contacts Thermal image Cable box (HV / LV) Oil level indicator with contacts (if not hermetic) PT100 sensors for oil temperature control (PTO) Horn arrestor Others (see Manufacturer) High voltage & low voltage windings The primary and secondary windings are made with electrolytic aluminum or copper, with insulation in pure cellulose paper or in double enamel for wires of small diameter. These windings are oval or circular section and are a concentric type, coaxial to the core columns. The high voltage winding is made with a wire or a metal strip, helically wound with more layers or with continuous disc in relationship to the working voltage and the transformer's power. The low voltage windings are made with foil or strip and are equipped with terminal bars welded along the whole coil length in order to guarantee the correct sturdiness and electro-mechanical stress. Each winding layer of low and medium voltage is insulated with pure cellulose paper, the oil's circulation and necessary cooling are assured by wide channels placed between the windings layers. Insulation between high and low voltage and between the latter and the core is made with compressed cardboard cylinders with a well-sized thickness. Avvolgimenti di alta e bassa tensione ENG ITA Gli avvolgimenti primari e secondari dei trasformatori in olio sono costruiti in alluminio e/o rame elettrolitico con isolamento dei conduttori in carta di pura cellulosa o per fili di piccolo diametro, in smalto doppio. Questi avvolgimenti sono a sezione ovale o circolare e del tipo concentrico, coassiali alle colonne del nucleo. L’avvolgimento di alta tensione è realizzato in filo o piattina, avvolto ad elica in più strati o a disco continuo in relazione alle tensioni d’esercizio e alla potenza del trasformatore. Avvolgimento di bassa tensione è realizzato in lastra e piattina e presenta i terminali eseguiti in piatto saldato in tutta la lunghezza dell'avvolgimento che ne garantisce la robustezza e resistenza alle sollecitazioni elettrodinamiche. Ogni strato degli avvolgimenti di alta e bassa tensione è isolato con carta di pura cellulosa. Ampi canali, posti tra gli strati degli avvolgimenti, assicurano la circolazione dell’olio ed il necessario raffreddamento. L’isolamento tra alta e bassa tensione e tra questa ed il nucleo è effettuato con cilindri di cartogeno precompresso di spessore adeguato. 7 Commutatori per la regolazione e per variazione della tensione primaria La regolazione e la variazione della tensione primaria è effettuata con commutatori lineari immersi nell’olio e manovrabili a trasformatore disinserito dalla rete mediante manopole poste sul coperchio. Per evitare un errato posizionamento dei commutatori sono previsti dei fori in corrispondenza di ogni tacca di indicazione delle varie posizioni che consentono un sicuro alloggiamento della manopola. Se richiesto il trasformatore può essere dotato di commutatore a carico che consente la variazione con trasformatore in funzionamento delle tensioni di regolazione. GBE S.p.A. può realizzare trasformatori con tutte le marche di commutatori presenti sul mercato e fino a basse potenze. 8 ENG ITA Tap changers for adjustement or variation of primary voltage The adjustment or variation of primary voltage is done with linear tap changers in an oil bath and maneuverable with the transformer disconnected from the network by using knobs placed on the cover. To avoid an incorrect positioning of the tapchangers, are foreseen some holes in correspondence with each indication notch of the various positions that allow a secure housing of the knob; in addition, it is possible to apply a padlock to avoid accidental or unauthorized maneuvers. If required, the transformer may also be equipped with on-load tap changer, which regulates the voltage variation with working (energized) transformer. GBE S.p.A. offer transformers equipped with any make of on-load tap changer in the market also for small power range. The insulators Isolatori Insulating liquid ENG The filling of the transformers is obtained with mineral oil, without PBC, dried and degassed, with electrical and chemical specifications, which conform to the CEI and IEC standards; the filling is done under-vacuum for the best oil electrical rigidity withstand. If required the tank can be filled with silicon type dialectric oil, MIDEL or FR3. Liquido isolante Il riempimento del trasformatore è ottenuto con olio minerale dielettrico esente da PCB, essiccato e degasato, con caratteristiche chimiche ed elettriche conformi alle norme CEI in vigore: il riempimento è effettuato sotto vuoto per la massima tenuta elettrica della rigidità elettrica dell’olio. A richiesta il riempimento può essere effettuato con olio dielettrico di tipo siliconico, MIDEL o FR3. The high and low voltage bushings are oil filled type in enameled brown porcelain according IEC standards. The insulators are fixed on the conver with special frames and and may be substituted without removing the core and coil assembly. High voltage bushings may be equipped on request with spark gap rods. The high voltage bushings are provided with spark grip rods. Cast resin insulators suitable for Elastimold type connectors can be delivered upon request. For the whole range of GBE oil immersed products we have studied, developed and designed new gaskets for outdoor installation bushings that are: from -60°C, -40°C, -25°C up to 120°C or 150°C. ENG ITA ITA Gli isolatori passanti di alta e bassa tensione sono del tipo per esterno in porcellana smaltata color bruno riempiti d’olio e conformi alla normativa IEC. Gli isolatori sono fissati sul coperchio mediante appositi telai e sono sostituibili senza estrarre il frutto dalla cassa. Gli isolatori di alta tensione su richiesta possono essere muniti di aste spinterometriche. Gli isolatori di alta tensione sono muniti di aste spinterometriche. Gli isolatori possono essere anche in resina per attacco Elastimold oppure passanti. Per tutta la gamma dei prodotti GBE in olio sono state studiate, progettate e sviluppate delle nuove guarnizioni per isolatori per applicazione esterna: da -60°C, -40°C, -25°C fino a 120°C oppure 150°C. 9 Standard accessories ENG ITA Accessori d’uso 10 Tutti i trasformatori sono dotati dei seguenti accessori standard: • Conservatore dell’olio sopra il coperchio (per trasformatori non ermetici) • Indicatore di livello montato sul conservatore (per trasformatori non ermetici) • Commutatore a vuoto sopra il coperchio per regolazione della tensione primaria del ± 2x2,5% • n°3 isolatori in porcellana lato MT (DIN 42 531) • n°3 isolatori in porcellana lato BT + n°1 isolatore in porcellana per il neutro (DIN 42530) • Valvola di riempimento olio • Valvola di scarico olio (DIN 42 551) • n°4 ruote di scorrimento orientabili ortogonalmente (DIN 42 561) • n°1 targa caratteristiche IEC 60076 • Golfari di sollevamento • n°2 morsetti di terra • Pozzetto/i termometrico/i (DIN 42 554) All our transformers are equipped with following standard accessories: •Oil conservator mounted on the tank top cover (for non hermetically sealed transformers) •Oil level indicator on the conservator (for non hermetically sealed transformers) •MV regulation tappings ± 2x2,5% wired to off-circuit tap changing switch with external operating handle •MV screwed, fully insulated porcelain bushings, 3 off, (DIN 42 531) requirements •LV Porcelain bushings, 3 off line terminals plus Neutral bushing, (DIN 42530) requirements •Oil filler cap •Oil drain valve (DIN 42 551) requirements •n°4 bi-directional floor rollers (DIN 42 561) requirements •n°1 rating and name plate (IEC 60076) requirements •Lifting lugs/eyebolts •n°2 earthing terminals •Thermometer pocket in accordance (DIN 42 554) The tank ITA ENG La cassa dei trasformatori può essere del tipo a onde elastiche oppure con radiatori in lamiera stampata e laminata a freddo. I radiatori sono provati singolarmente prima del loro montaggio. Se previsto i trasformatori sono dotati di normale conservatore per l’espansione dell’olio a caldo. Per trasformatori fino a 4000 KVA è possibile la soluzione a riempimento integrale senza conservatore. Le parti interne delle casse sono protette, previa sabbiatura, con speciali vernici insolubili all’olio caldo. Le pareti esterne subiscono un ciclo protettivo con vernice idrosolubile, RAL 7031 o RAL 7033 con spessore di verniciatura 100-120 micron, e sono adatte alle più severe condizioni ambientali. Cassa The transformer tank is available in two versions: corrugated (finned) tank or with radiators, made with cold rolled and laminated steel. All radiators are singularly tested before their assembling. If required the transformer may be supplied with a traditional expansion conservator. All transformers up to 4000 KV can be filled without conservator. The inside walls of tanks are protected, prior to sand blasting, with special paint insoluble to hot oil. The outside walls are protected with water resistant paint RAL 7031 or RAL 7033 with painting thickness of 100120 micron, suitable to the strictest environmental conditions. 11 Accessories upon request ENG ITA Accessori a richiesta 12 Ove richiesto, è possibile equipaggiare i trasformatori dei seguenti accessori: • Relè buchholz di protezione a 2 contatti (per trasformatori non ermetici) • Essiccatore d’aria al silicagel completo di carica sali (per trasformatori non ermetici) • Presenza contatti per indicatore di livello olio (per trasformatori non ermetici) •Valvola di sovrapressione (per trasformatori ermetici) • Sistema di protezione integrato DGPT2 o RIS (per trasformatori ermetici) • Termometro a quadrante a 2 contatti elettrici • Cassonetto di protezione IP55 per isolatori BT • Cassonetto di protezione IP55 per isolatori MT • Set antivibranti • Relè di pressione a 2 contatti • Schermo elettrostatico tra primario e secondario • Slitte per appoggio su palo On request following additional accessories can be delivered: •Gas and oil operated Buchholz relay with 2 electrical contacts • Dehydrating breather (for non hermetically sealed transformers) • Oil level indicator contacts on the conservator (for non hermetically sealed transformers) • Pressure relief valve (hermetically sealed transformers) • Protection system DGPT2 or RIS (for hermetically sealed transformers) • Thermometer with 2 electrical contacts • Protection housing IP 55 for LV bushings • Protection housing IP 55 for MV bushings • Antivibration pads for wheels • Pressure relay with 2 electrical contacts • Electrostatic screen between primary and secondary voltage • Skids for pole mounted transformers 13 14 Finished products Prodotti finiti Tutta la produzione GBE è progettata e costruita in conformità alle seguenti norme: All our products are designed and manufactured according the following rules: • • • • • • • • • • • • IEC 60076; EN 50464; IEC 61378-1 EN 50216 ISO 9001:2008 ISO 14001:2004 IEC 60076; EN 50464; IEC 61378-1 EN 50216 ISO 9001:2008 ISO 14001:2004 Test reports & witnessed tests Quality of GBE products Quality of GBE products Qualità del prodotto GBE Qualità del prodotto GBE All transformers are tested in our test-room according IEC 60076 norms. All transformers are delivered with maintenance manual, test report, technical drawing and all necessary certifications. the offer to the after sale service. GBE S.p.A. has test room with very high level equipment. We are able to make all acceptance tesst, without any exception. Our test room is equiped with special converter 400 A up to 12000V and permits to change the frequency up to 400 Hz. Furthermore there is a impluse test device, which guarantees impuls test range up to 1.200.000 V. All our products are manufactured according to ISO 9001:2008 and ISO 14001:2004. Prove e collaudo ENG ITA Tutti i trasformatori sono sottoposti presso la nostra sala prove ai collaudi secondo le norme IEC 60076. Sono inoltre corredati di manuale d’uso e manutenzione, bollettino di collaudo, certificato di conformità e disegni d’ingombro. GBE S.p.A. dispone di una sala prove altamente avanzata. Siamo in grado di fare tutte le prove di accettazione, nessuna esclusa. La sala prove dispone di un convertitore 400 A fino a 12000 V con possibilità di variare la frequenza fino a 400 Hz. Inoltre siamo in possesso di uno strumento la prova d’impulso fino a 1.200.000 V. La nostra produzione è certificata secondo le norme ISO 9001:2008 e la ISO 14001:2004. 15 stage. Livello Isolamento MT / Rated Voltage HV Norme Livello Isolamento BT / Rated Voltage LV Uk 4% Uk 6% TS3R07-TS3R12 (CoBk) 50 100 160 200 250 315 400 500 630 4 4 4 4 4 4 4 4 4 300 440 610 715 820 960 1150 1300 1500 1250 1700 2300 2700 3000 3600 4300 5300 6400 50 100 160 200 250 315 400 500 630 6 6 6 6 6 6 6 6 6 380 440 610 700 820 950 1150 1300 1500 1400 1800 2400 2800 3100 3700 4400 5400 6500 800 6 1800 1000 6 2100 6 1600 A B C LwA Isolamento LpA Classe BT / Insulation Class LV (mm) (mm) (mm) (dB(A)) (dB(A)) D FI 3 kVKg (mm) 1600 2000 2700 3100 3500 4200 4900 6100 7300 1,92 1,68 1,6 1,5 1,42 1,3 1,18 0,96 0,85 8000 9000 8800 10000 2500 10700 6 2800 2000 6 2500 Regolazione MT / Tappings HV 48 50 53 54 55 57 58 58 59 1040 1040 1120 1230 1270 1300 1300 1380 1410 670 670 670 670 670 820 820 820 820 1100 1150 1200 1300 1300 1400 1500 1550 1650 47 59 62 64 65 67 68 69 70 39 50 53 55 55 57 58 59 59 1040 1120 1120 1230 1270 1300 1330 1380 1410 670 670 670 670 670 820 820 820 820 0,72 71 60 1460 0,64 73 62 1510 12000 0,56 75 63 12700 14500 0,52 76 3600 16000 18000 0,48 6 4300 18000 21000 3150 6 5300 22900 4000 7÷8 pcc (75°C) 7÷8 6800 Uk 25600 po (W) (W) 7500 (75°C) % ± 4% or ± 2x2,5% 520 520 520 520 520 670 670 670 670 400 520 750 870 1010 1150 1340 1590 1820 900 1100 1150 1200 1300 1300 1400 1500 1550 520 520 520 520 520 670 670 670 670 380 500 720 840 970 1100 1290 1530 1760 1000 1650 820 2080 1000 1750 820 2480 1620 1000 1850 820 2870 64 1640 1000 2150 820 3350 78 66 1710 1300 2150 1070 3950 0,45 81 68 1790 1300 2250 1070 4700 26000 0,4 83 70 2060 1300 2450 1070 5640 28780 0,32 84 70 2500 p 2680 (mm) 1070 J 1250 (mm) 7700 G 9600 (mm) 520 900 520 1100 520 1150 520 1200 670 1300 670 1300 670 1400 670 1500 670 1550 670 1700 820 1750 820 1950 820 2200 1070 2250 1070 2300 265 520 265 520 265 520 265 520 265 520 265 670 265 670 265 670 265 670 265 820 265 820 265 820 265 820 265 1070 265 1070 1070 1070 1250 90 400 90 530 90 760 120 880 120 1020 120 1160 120 1360 130 1610 130 1850 130 2190 150 2610 150 3020 180 3530 180 4160 220 4950 5940 8100 10100 2150 1300 lwA Total A b C D M oil 28400 31950 0,29 85 71 2260 1500 dB(A) (kg) (kg) (mm) (mm) (mm) (mm) (mm) PERDITE STANDARD 24 kV10357201365 / STANDARD LOSSES 24 kV265 90 100320 2150 4 59CLASSE 580 150 980CLASS 125 520 160 460 3100 4 62 750 180 1095 730 1445 1060 125 520 265 FI 50 kV90BIL Classe Isolamento MT / Insulation Class HV Livello Isolamento MT / Rated Voltage HV 24 kV 200550 3640 4 64 870 240 116581514901105125 520 265 95 kV90 250 650 4200 4 65 1010 230 1225 845 1490 1105 125 520 265 120 Livello Isolamento BT / Rated Voltage LV Classe Isolamento BT / Insulation Class LV FI 3 kV 1,1 kV 315 770 5000 4 67 1170 260 1255 870 1530 1145 125 670 265 120 400 Frequenza 930 6000 4 68 133050÷60 300 1675 MT 1290 125 670 265± 2 x 2,5% 120 / Frequency Regolazione / Tappings HV Hz 1255 870 500 1100 7200 4 69 1500 330 1320 870 1675 1290 125 670 265 120 Pcc 380 I 1360 870 1785 A1400 B125 Uk 630 1300 8400 4Po 70Pcc 1780 670 265 130 C D LwA LpA 0 Kg GBE (75°C) CEI-EN (120°C) 630 KVA 1200 (120°C) 8700 6 70 1770 430 % 1455 885 (dB(A)) 1715 (mm) 1330 (mm) 125 (mm) 670 (mm) 265 130 (W) (dB(A)) (W) (W) % 800 1400 10500 6 71 2030 480 1730 885 1785 1400 125 670 265 130 50 13000 4 1570 520 430 1000 1700 300 6 731400 2400 5502,74 1810 58 1110 491870 1040 1485 670 150 1100 820 265 150 4 1600 1750 520 570 1250 100 2100 16000 400 6 74 2760 6202,15 1850 59 1110 501950 1040 1565 670 150 1150 820 265 150 160 20000 4 2200 2500 520 820 1600 2600 580 6 76 3350 7901,97 2020 62 1110 532015 1070 1630 670 150 1200 820 265 180 200 26000 4 2600 2980 520 950 2000 3100 690 6 78 4120 9501,92 2170 64 1380 542190 1250 1805 670 200 1300 1070 265 180 250 32000 4 3450 520 1100 2500 3500 800 6 813000 4910 11401,73 2285 65 1380 552305 1250 1920 670 200 1300 1070 265 220 315 4 950 3700 4170 1,72 67 57 1250 820 1400 670 1250 400 4 1100 4400 4900 1,51 68 58 1330 820 1500 670 1470 pcc Uk lwA p J G po 500 4 1350 4900 Total 5550 oil 1,16 A 69 b 58 C 1330D 820M 1550 670 1740 (75°C) KvA (75°C) dB(A) (kg) (kg) (mm) 820 (mm) 1650 (mm) (mm) (mm) (W) (W) 630 4 1600 6100 6900 1,08 (mm) 70 (mm) 59(mm) 1360 670 2000 % Uk 4% TE3024 - TE3012 - EoDk (ex BA') 2 x 2,5% FI±28÷50 kV BIL 75÷125 kV 57 59 62 64 65 67 68 69 70 5000 FI 3 KV Regolazione MT / Tappings HV Classe Isolamento MT / Insulation Class HV 2,43 1,91 1,75 1,71 1,54 1,53 1,34 1,17 0,96 100 160 200 250 315 400 500 630 630 800 1000 1250 1600 2000 2500 210 50 300 100 370 160 425 200 520 250 610 315 720 400 860 500 800 630 930 800 1100 1000 1350 1250 1700 1600 2100 2000 2500 2500 3150 16 50÷60 Hz 12÷24 kV Pcc I0 kV CEI-EN1,1 (120°C) % (W) 50÷60 hz 1420 2000 2700 3050 3500 4100 4900 5950 7300 X=300÷600 mm1250 28 kV BIL 75 kV / standards CEI EN BT 50464 Classe –Isolamento / Insulation Class LV 1,1 kV CEI EN 60076 Pcc Uk Po Livello Isolamento BT / Rated Voltage LV GBE (75°C) KVA (120°C) (W) (W) % Frequenza / Frequency KvA Classe Isolamento MT / Insulation Class HV 12 kV Frequenza / Frequency Livello Isolamento MT / Rated Voltage HV Uk 6% Characteristic are indicative. GBE will confirm actual data at offer/order PERDITE STANDARD CLASSE 12 kV / STANDARD LOSSES CLASS 12 kV TZ3024 - TZ3012 - CoDk (ex bC’) TS3R17-TS3R24 (CoBk) Technical data sheet series EoDk (ex BA')- CoDk (ex BC') Standard line with losses according to EN 50541 - 1/2011 Scheda serie EoDk (ex BA') CoDk (ex- BC') Serietecnica perdite standard EN -50541 1/2011 Dati e caratteristiche sono indicativi e non impegnativi. La GBE si riserva di comunicare i dati effettivi in fase di offerta. Norme / Standards IEC 60076 – CEI EN 60076 – DIN EN 60076 – EN50541-1 4000 5000 2150 6 3100 6 3640 6 4200 6 5000 6 6000 6 7200 6 8400 6 8700 6 10500 6 13000 6 16000 6 20000 6 26000 6 32000 6 6 7÷8 7÷8 4 360 4 460 4 650 4 770 4 880 4 1050 4 1200 4 1450 6 1650 6 2000 6 2300 6 2800 6 3100 6 4000 6 5000 6000 7000 8100 49 1600 52 1800 54 2600 55 3000 57 3300 58 4100 59 4800 60 5800 606800 618300 63 9600 64 11500 66 14000 68 16000 71 20000 23500 26600 29400 590 1750 750 2050 880 2900 1020 3350 1190 3800 1340 4650 1520 5500 1790 6550 1780 7600 2050 9400 2420 11000 2790 13000 3380 16000 4170 18000 4960 23000 28000 29930 33100 140 2,4 180 2,1 240 2 2301,87 2601,78 3001,65 3301,48 380 1,2 4201,06 480 0,9 550 0,8 620 0,7 790 0,65 940 1140 0,6 0,56 0,5 0,4 0,36 1035 1095 1165 1225 1255 1255 1320 1360 1455 1730 1810 1850 2020 2170 2285 58 59 62 64 65 67 68 69 70 72 73 75 76 78 81 83 86 88 720 501365 730 1445 50 815 1490 53 845 551490 870 551530 870 571675 870 581675 870 591785 885 591715 885 611785 1110 1870 62 1110 1950 63 1110 2015 1380 632190 1380 652305 68 70 72 74 1040980 1060 1070 1105 1250 1250 1105 1250 1145 1330 1290 1330 1290 1360 1400 1410 1330 1570 1400 1485 1570 1565 1740 1630 1740 1805 1860 1920 2010 2100 2260 2380 125 670 125 670 125 670 125 670 125 670 125 820 125 820 125 820 125 820 125 1000 150 1000 150 1000 150 1000 200 1300 200 1300 1300 2450 1300 2500 1500 2680 Livello Isolamento MT / Rated Voltage HV Livello Isolamento BT / Rated VoltageNorme LV Frequenza / Frequency Livello Isolamento MT / Rated Voltage HV TD3R07-TD3R12 (BoBk) Uk 4% Uk Po VoltagePcc Livello KVA Isolamento BT / Rated LV GBE (75°C) (120°C) (W) (W) % Frequenza / Frequency 50 100 160 200 250 315 400 500 630 Uk 6% 50 100 160 200 250 315 400 X=300÷600500 mm 630 4 4 4 4 4 4 4 4 4 230 330 450 540 610 750 880 1020 1150 1250 1700 2300 2700 3000 3600 4300 5300 6400 6 6 6 6 6 6 6 6 6 290 330 450 540 610 730 880 1000 1150 1400 1800 2400 2800 3100 3700 4400 5400 6500 6 pcc 1300Uk 8000 lwA (75°C) (75°C) dB(A) (W) 6 (W) 1500 % 8800 1250 6 1800 10700 100 320 1750 4 59 1600 6 2200 12700 160 460 2350 4 62 2000 6 2600 16000 200 550 2800 4 64 2502500 650 6 3250 3200 4 18000 65 3153150 770 6 3900 3800 4 22900 67 4004000 930 7÷8 4600 5240 4 25600 68 5005000 1100 7÷8 5500 5780 4 28400 69 630 1300 6500 4 70 630 1200 6750 6 70 800 1400 8400 6 71 Livello Isolamento Rated Voltage 1000 1700 MT /10500 6 HV 73 1250 2100 13500 6 74 Livello Isolamento Rated Voltage 1600 2600 BT / 17000 6 LV 76 2000Frequenza 3100 / Frequency 21000 6 78 2500 3500 26500 6 81 3150 4500 Uk 33000 Po 6 Pcc84 KVA 4000* 5300(120°C) 38000 (W) 7 GBE (75°C) 86 (W) % 5000* 6000 43000 7 88 6300*50 6800 4 47000 270 8 1400 90 100 4 360 1600 160 po 4 pcc 490 Uk 2200 lwA (75°C) KvA200 (75°C) dB(A) (W) 4 (W) 590 % 2600 250 4 660 3000 100 315 210 4 1750 830 4 3700 49 160 400 300 4 2350 970 4 4400 52 200 500 370 4 2800 1150 4 4900 54 250 630 425 4 3250 1270 4 6100 55 315 50 520 6 3900 250 4 1600 57 400 610 4600 4 58 100 6 340 1800 500 160 720 6 5500 480 4 2600 59 630 200 860 6 6500 570 4 3000 60 630 250 800 6 6750 650 6 3300 60 800 315 930 6 8400 800 6 4100 61 1000400 1100 6 10500 940 6 4800 63 1250500 1350 6 135001100 6 5800 64 1600630 1700 6 170001250 6 6800 66 2000800 2100 6 210001500 6 8300 68 2500 2500 26500 6 71 1000 6 1800 9600 3150 3000 33000 6 73 1250 6 2100 11500 4000* 3500 38000 7 75 1600 5000* 3900 6 430002400 7 14000 76 2000 6300* 4300 6 470003000 8 16000 77 2500 6 3600 20000 800 po TC3024 - TC3012 - EoCk (ex AA’) KvA1000 28 kV BIL 75 kV Classe Isolamento MT / Insulation Class HV 12 kV / standards CEI ENClasse 60076 – CEI BT EN/ 50464 Isolamento Insulation Class LV 1,1 kV 50÷60 Hz 12÷24 kV Pcc I 1,1 kV 0 CEI-EN (120°C) % (W) 50÷60 hz FI 3 kV ± 2FIx 28÷50 2,5% kV BIL 75÷125 kV Regolazione MT / Tappings HV Classe Isolamento MT / Insulation Class HV A B C LwAClasse LpA Isolamento BT / Insulation Class LV (mm) (mm) (mm) (dB(A)) (dB(A)) 1420 2000 2700 3050 3500 4100 4900 5950 7300 2,25 1,77 1,62 1,58 1,42 1,42 1,24 0,95 0,89 50 51 54 56 57 59 60 61 62 1600 2000 2700 3100 3500 4200 4900 6100 7300 1,78 1,56 1,48 1,39 1,32 1,22 1,1 0,89 0,79 50 51 54 56 57 59 60 61 62 Regolazione MT / Tappings HV D (mm) FI 3KgkV ± 4% or ± 2x2,5% 41 42 45 46 47 49 50 50 51 1040 1040 1120 1230 1270 1300 1300 1380 1410 670 670 670 670 670 820 820 820 820 1100 1150 1200 1300 1300 1400 1500 1550 1650 520 520 520 520 520 670 670 670 670 410 530 770 890 1030 1170 1370 1620 1860 42 42 45 47 47 49 50 51 51 1040 1120 1120 1230 1270 1300 1330 1380 1410 670 670 670 670 670 820 820 820 820 900 1100 1150 1200 1300 1300 1400 1500 1550 520 520 520 520 520 670 670 670 670 390 510 730 860 990 1120 1320 1560 1800 9000 Total 0,67 65 A b54 C1460 D1000 M 1650 p 820 J 2120 G oil 0,59 67 56 1510 1000 (mm) 1750 (mm) 820 (mm) 2530 (kg) (mm) (mm) (mm) (mm) (mm) 12000 0,52 69 57 1620 1000 1850 820 2930 590 140 1005 700 1365 980 125 520 265 90 14500 0,48 71 59 1640 1000 2150 820 3420 760 170 1065 710 1445 1060 125 520 265 90 18000 0,44 73 61 1710 1300 2150 1070 4030 890 230 1130 790 1490 1105 125 520 265 90 21000 75 820 62 1490 1790 1300 1030 0,41 220 1190 1105 1252250 520 1070 265 4790120 26000 77 845 64 1530 2060 1300 1200 0,37 250 1220 1145 1252450 670 1070 265 5750120 28780 80 845 66 1675 2150 1300 1360 0,3 290 1220 1290 1252500 670 1070 265 7850120 1530 0,27 320 1280 1290 1252680 670 1250 265 9790120 31950 82 845 68 1675 2260 1500 1810 370 1320 845 1785 1400 125 670 265 130 1800 410 1415 860 1715 1330 125 670 265 130 2070 460 1680 860 1785 1400 125 670 FI 50 265kV BIL130 Classe MT / Insulation 24 kV 540 2450 1755 Isolamento 1080 1870 1485 Class 150 HV 820 265 150 95 kV 2820 610 1795 1080 1950 1565 150 820 265 150 Classe BT / Insulation FI 1,1 kV 3420 770 1960 Isolamento 1080 2015 1630 Class 150 LV 820 2653 kV 180 4210 Hz 920 2105 Regolazione 1340 2190 1805 HV200 1070 ± 2265 180 MT / Tappings 50÷60 x 2,5% 5010 1110 2220 1340 2305 1920 200 1070 265 220 Pcc 6280 1380 I0 2495 LwA 1410 LpA 2390A 2105B 200 C 1070 D 265 Kg 265 CEI-EN7410 (120°C) 1700 2680 1495 2390 2105 200(mm) 1070(mm) 265 265 (mm) (mm) % (dB(A)) (dB(A)) (W) 9030 2190 2885 1565 2470 2085 200 1070 265 265 1570 50 1625 41 2585 1040 670 2001100 11020 2,50 2640 3090 2200 1070 520 265 460 265 1750 1,94 51 42 1040 670 1150 520 610 2500 54 Total 1,78 A b45 C1250 D670 M1200 p 520 J 870 G oil 2980 1,73 56 46 1250 (mm) 670 (mm) 1300 (mm) 520 (mm) 1010(mm) (kg) (kg) (mm) (mm) (mm) 3450 1,56 57 47 1250 670 1300 520 1170 4170 59 700 49 1365 1330 600 1,54 140 1005 980820 1251400 520 670 265 1330 90 4900 60 710 50 1445 1330 820 770 1,36 170 1065 1060 1251500 520 670 265 1570 90 5550 61 790 50 1490 1360 820 900 1,05 230 1130 1105 1251550 520 670 265 1850 90 6900 62 820 51 1490 1410 820 1040 0,97 220 1190 1105 1251650 520 670 265 2130120 1210 2,16 250 1220 1145 670 520 265 430 120 1750 50 845 42 1530 1040 670 125 900 1370 290 1220 845 1675 1290 125 670 265 120 2050 1,89 51 42 1070 670 1100 520 560 1550 1,8 320 1280 1290 1251150 670 520 265 810 120 2900 54 845 45 1675 1250 670 1830 1,68 370 1320 1400 1251200 670 520 265 940 130 3350 56 845 47 1785 1250 670 1820 1,6 410 1415 1330 1251300 670 520 265 1090130 3800 57 860 47 1715 1250 670 2090 1,48 460 1680 1400 1251300 670 670 265 1240130 4650 59 860 49 1785 1330 820 2470 1,33 530 1755 1485 1501400 820 670 265 1450150 5500 60 1080 50 1870 1330 820 2850 1,08 600 1795 1565 1501500 820 670 265 1710150 6550 61 1080 51 1950 1360 820 3450 0,95 760 1960 1630 1501550 820 670 265 1970180 7600 62 1080 51 2015 1410 820 4250 0,81 910 2105 1805 2001700 1070 820 265 2330180 9400 64 1340 53 2190 1570 1000 5060 1100 2220 1340 2305 1920 200 1070 265 220 11000 0,72 65 54 1570 1000 1750 820 2780 6340 1370 2495 1410 2390 2105 200 1070 265 265 13000 0,63 67 55 1740 1000 1950 820 3220 7480 1680 2680 1495 2390 2105 200 1070 265 265 16000 68 1565 55 2470 1740 1000 9120 0,59 2170 2885 2085 2002200 1070 820 265 3760265 18000 70 1625 57 2585 1860 1300 11130 0,54 2610 3090 2200 2002250 10701070 265 4430265 23000 0,5 71 58 2010 1300 2300 1070 5270 10000 (kg) Uk 6% TD3R17-TD3R24 (BoBk) TD3024 - TD3012 - CoCk (ex AC’) Uk 4% PERDITE RIDOTTE CLASSE 24 kV / REDUCED / LOSSES CLASS 24 kV * solo versione6 con conservatore/NOT provided on hermetically sealed transformers 3150 4300 23500 28000 0,45 74 61 2100 1300 2450 1070 4000 7÷8 5800 26600 29930 0,36 81 67 2260 1300 2500 1070 8630 5000 7÷8 7100 29400 33100 0,32 83 69 2380 1500 2680 1250 10760 Technical dataline sheet (ex AA')CoCk (ex AC') Reduced withseries lossesEock according to EN 50541 - 1/2011 PERDITE RIDOTTE CLASSE 12 kV / REDUCED LOSSES CLASS 12 kV Scheda tecnica serie Eock (ex AA') CoCk (ex -AC') Serie perdite ridotte EN- 50541 1/2011 Norme / Standards IEC 60076 – CEI EN 60076 – DIN EN 60076 – EN 50541-1 Dati e caratteristiche sono indicativi e non impegnativi. La GBE si riserva di comunicare i dati effettivi in fase di offerta. Characteristic are indicative. GBE will confirm actual data at offer/order stage. 6330 17 stage. Livello Isolamento MT / Rated Voltage HV Norme Livello Isolamento BT / Rated Voltage LV Uk 4% Uk 6% TS3R07-TS3R12 (CoBk) 4 4 4 4 4 4 4 4 4 300 440 610 715 820 960 1150 1300 1500 1250 1700 2300 2700 3000 3600 4300 5300 6400 50 100 160 200 250 315 400 500 630 6 6 6 6 6 6 6 6 6 380 440 610 700 820 950 1150 1300 1500 1400 1800 2400 2800 3100 3700 4400 5400 6500 TR3024 - TR3012 - CoDk (ex CC’) 2 x 2,5% FI ±28÷50 kV BIL 75÷125 kV A B C LwA Isolamento LpA Classe BT / Insulation Class LV (mm) (mm) (mm) (dB(A)) (dB(A)) D FI 3 kV Kg (mm) 1420 2000 2700 3050 3500 4100 4900 5950 7300 2,43 1,91 1,75 1,71 1,54 1,53 1,34 1,17 0,96 57 59 62 64 65 67 68 69 70 1600 2000 2700 3100 3500 4200 4900 6100 7300 1,92 1,68 1,6 1,5 1,42 1,3 1,18 0,96 0,85 Regolazione MT / Tappings HV 48 50 53 54 55 57 58 58 59 1040 1040 1120 1230 1270 1300 1300 1380 1410 670 670 670 670 670 820 820 820 820 1100 1150 1200 1300 1300 1400 1500 1550 1650 47 59 62 64 65 67 68 69 70 39 50 53 55 55 57 58 59 59 1040 1120 1120 1230 1270 1300 1330 1380 1410 670 670 670 670 670 820 820 820 820 ± 4% or ± 2x2,5% 520 520 520 520 520 670 670 670 670 400 520 750 870 1010 1150 1340 1590 1820 900 1100 1150 1200 1300 1300 1400 1500 1550 520 520 520 520 520 670 670 670 670 380 500 720 840 970 1100 1290 1530 1760 800 6 1800 8000 9000 0,72 71 60 1460 1000 1650 820 2080 6 2100 8800 10000 0,64 73 62 1510 1000 1750 820 2480 1250 6 2500 10700 12000 0,56 75 63 1620 1000 1850 820 2870 1600 po pcc 6 2800 Uk 820 J 1070 (mm) 3350 G 3950 (mm) 4700 90 5640 90 7700 90 9600 120 Uk 4% 100 160 200 250 315 400 500 630 630 800 1000 1250 1600 2000 2500 FI 3 KV Regolazione MT / Tappings HV Classe Isolamento MT / Insulation Class HV 1000 145 50 210 100 260 160 300 200 360 250 430 315 510 400 500 600 560 630 650 800 770 1000 950 1250 1200 1600 1450 2000 1750 2500 3150 18 50÷60 Hz 12÷24 kV Pcc I0 1,1(120°C) kV CEI-EN % (W) 50÷60 hz 12700 Total 14500 oil 0,52 A 76 b 64 C 1640D 1000M 2150 lwA p (75°C) KvA 2000 (75°C) 6 3600 dB(A) 16000 (kg) 18000 (kg)0,48 (mm) 78 (mm) 66(mm) 1710 1300 2150 (mm) (mm) (mm) (W) (W) % 2500 6 4300 18000 21000 0,45 81 68 1790 1300 2250 100 210 1475 4 49 700 170 1065 710 1445 1060 125 520 3150 6 5300 22900 26000 0,4 83 70 2060 1300 2450 160 300 2000 4 52 890 200 1130 725 1490 1105 125 520 7÷8 25600 28780 200 4000 370 2350 6800 4 54 1050 240 0,32 1190 84 735 701590 2150 1205 1300 125 2500 520 7÷8 28400 31950 250 5000 425 2750 7500 4 55 1180 270 0,29 1220 85 740 711635 2260 1250 1500 125 2680 520 315 520 3250 4 57 1350 290 1280 845 1635 1250 125 670 PERDITE STANDARD CLASSE 24 kV1320 / STANDARD LOSSES CLASS670 24 400 610 3850 4 58 1530 330 845 1715 1330 125 500 720 4600 4 59 1830 400 1415 895 1715 1330 125 670 Classe Isolamento MT / Insulation Class HV Livello Isolamento MT / Rated Voltage HV 24 kV 630 860 5400 4 60 2060 440 1415 925 1870 1485 125 670 630 800 5600 6 60 2140 450 1485 920 1830 1445 125 670 Livello Isolamento BT / Rated Voltage LV Classe Isolamento BT / Insulation Class LV 1,1 kV 800 930 7000 6 61 2420 540 1550 915 1830 1445 125 670 1000 1100 9000 6 63 273050÷60 580 1950 MT 1565 150 820 Frequenza / Frequency Regolazione / Tappings HV Hz 1550 1080 1250 1350 11000 6 64 2920 630 1815 1080 2015 1630 150 820 Uk 6Po 1600 1700 14000 66Pcc 3520Pcc 770 I 1905 LwA 1080 LpA2105 A1720 B150 820 C 0 GBE (75°C) CEI-EN (120°C) KVA (120°C) 2000 2100 18000 (W) 6 68(W) 4170 890 1995 1340 2190 1805 200 1070 (mm) (mm) (mm) % (dB(A)) (dB(A)) (W) % 2500 2500 22000 6 71 4990 1040 2160 1340 2305 1920 200 1070 50 4 300 1400 1570 2,74 58 49 1040 670 1100 100 4 400 1600 1750 2,15 59 50 1040 670 1150 160 4 580 2200 2500 1,97 62 53 1070 670 1200 200 4 690 2600 2980 1,92 64 54 1250 670 1300 250 4 800 3000 3450 1,73 65 55 1250 670 1300 315 4 950 3700 4170 1,72 67 57 1250 820 1400 400 4 1100 4400 4900 1,51 68 58 1330 820 1500 pcc Uk lwA p po 500 4 1350 4900 Total 5550 oil 1,16 A 69 b 58 C 1330D 820M 1550 (75°C) (75°C) KvA dB(A) (kg) (kg) (mm) 820 (mm) 1650 (mm) (W) 630 4 1600 6100 6900 1,08 (mm) 70 (mm) 59(mm) 1360 (W) % 28 kV BIL 75 kV / standards CEI EN 50464 Classe–Isolamento BT / Insulation Class LV 1,1 kVCEI EN 60076 50 100 160 200 250 315 400 500 630 X=300÷600 mm Classe Isolamento MT / Insulation Class HV 12 kV Frequenza / Frequency Livello Isolamento MT / Rated Voltage HV Pcc Uk Po GBE (75°C) Livello Isolamento BT / Rated Voltage LV KVA (120°C) (W) (W) % Frequenza / Frequency Uk 6% Characteristic are indicative. GBE will confirm actual data at offer/order PERDITE STANDARD CLASSE 12 kV / STANDARD LOSSES CLASS 12 kV TU3024 - TU3012 - Aobk (ex CC’R) TS3R17-TS3R24 (CoBk) Technical data sheet series Codk (ex CC') - AoBk (ex CC'R) Standard line with losses according to EN 50541 - 1/2011 Scheda seriestandard Codk (ex CC') (ex CC'R) Serietecnica perdite EN- AoBk 50541 - 1/2011 Dati e caratteristiche sono indicativi e non impegnativi. La GBE si riserva di comunicare i dati effettivi in fase di offerta. Norme / Standards IEC 60076 – CEI EN 60076 – DIN EN 60076 – EN50541-1 4000 5000 1475 6 2000 6 2350 6 2750 6 3250 6 3850 6 4600 6 6 5400 5600 6 7000 6 9000 6 11000 6 14000 6 18000 6 22000 6 6 7÷8 7÷8 4 360 4 460 4 650 4 770 4 880 4 1050 4 1200 1450 4 6 1650 6 2000 6 2300 6 2800 6 3100 6 4000 6 5000 6000 7000 8100 41 1600 44 1800 46 2600 47 3000 49 3300 50 4100 51 4800 5800 52 52 6800 53 8300 55 9600 56 11500 58 14000 60 16000 63 20000 23500 26600 29400 710 1750 900 2050 1060 2900 1190 3350 1360 3800 1550 4650 1850 5500 6550 2080 2160 7600 2440 9400 2760 11000 2950 13000 3560 16000 4210 18000 5040 23000 28000 29930 33100 170 2,4 200 2,1 240 2 2601,87 2801,78 3201,65 3901,48 430 1,2 4401,06 530 0,9 570 0,8 620 0,7 750 0,65 870 1020 0,6 0,56 0,5 0,4 0,36 1065 1130 1190 1220 1280 1320 1415 1415 1485 1550 1550 1815 1905 1995 2160 58 59 62 64 65 67 68 69 70 72 73 75 76 78 81 83 86 88 710 501445 725 501490 735 531590 740 551635 845 551635 845 571715 895 581715 925 591870 920 591830 915 611830 1080 1950 62 1080 2015 63 1080 2105 1340 632190 1340 652305 68 70 72 74 1040 1060 1070 1105 1250 1205 1250 1250 1250 1250 1330 1330 1330 1330 1360 1485 1410 1445 1570 1445 1565 1570 1630 1740 1720 1740 1805 1860 1920 2010 2100 2260 2380 125 670 125 670 125 670 125 670 125 670 125 820 125 820 820 125 125 820 125 1000 150 1000 150 1000 150 1000 200 1300 200 1300 520 900 520 1100 520 1150 520 1200 670 1300 670 1300 670 1400 1500 670 670 1550 670 1700 820 1750 820 1950 820 2200 1070 2250 1070 2300 1300 2450 1300 2500 1500 2680 1070 265 1070 265 1070 265 1250 265 265 120 kV265 120 265 FI 50 kV120 BIL 265 95 kV 130 265 130 FI 3 kV 265 130 265± 2 x 2,5% 150 265 150 265 180 D Kg 265 180 (mm) 265 220 520 430 520 570 520 820 520 950 520 1100 670 1250 670 1470 J G 670 1740 (mm) (mm) 670 2000 265 520 265 520 265 520 265 520 265 520 265 670 265 670 670 265 265 670 265 820 265 820 265 820 265 820 265 1070 265 1070 1070 1070 1250 90 400 90 530 90 760 120 880 120 1020 120 1160 120 1360 1610 130 130 1850 130 2190 150 2610 150 3020 180 3530 180 4160 220 4950 5940 8100 10100 Livello Isolamento MT / Rated Voltage HV Livello Isolamento BT / Rated Voltage Norme LV Frequenza / Frequency Livello Isolamento MT / Rated Voltage HV Uk Po VoltagePccLV LivelloKVA Isolamento BT / Rated GBE (75°C) (120°C) (W) (W) % Frequenza / Frequency 230 330 450 540 610 750 880 1020 1150 1250 1700 2300 2700 3000 3600 4300 5300 6400 50 100 160 200 250 315 400 500 X=300÷600 630 mm 800 6 6 6 6 6 6 6 6 6 290 330 450 540 610 730 880 1000 1150 1400 1800 2400 2800 3100 3700 4400 5400 6500 6 1300 1000 6 1500 1250 6 1800 Uk 4% 4 4 4 4 4 4 4 4 4 Uk 6% TD3R07-TD3R12 (BoBk) 50 100 160 200 250 315 400 500 630 Classe Isolamento MT / Insulation Class HV 12 kV 28 kV BIL 75 kV / standards CEI EN 60076 – CEI BT EN/ Insulation 50464 Class LV Classe Isolamento 1,1 kV 50÷60 Hz 36 kV Pcc I CEI-EN (120°C)1,1 kV0 % (W) 50÷60 hz Regolazione MT / Tappings HV Classe Isolamento MT / Insulation Class HV A B C LwAClasseLpA Isolamento BT / Insulation Class LV (mm) (mm) (mm) (dB(A)) (dB(A)) Regolazione MT / Tappings HV FI 3 kV 28÷50 kV ± 2 FI x 2,5% BIL 75÷125 kV D (mm) FI Kg 3 kV ± 4% or ± 2x2,5% 1420 2000 2700 3050 3500 4100 4900 5950 7300 2,25 1,77 1,62 1,58 1,42 1,42 1,24 0,95 0,89 50 51 54 56 57 59 60 61 62 41 42 45 46 47 49 50 50 51 1040 1040 1120 1230 1270 1300 1300 1380 1410 670 670 670 670 670 820 820 820 820 1100 1150 1200 1300 1300 1400 1500 1550 1650 520 520 520 520 520 670 670 670 670 410 530 770 890 1030 1170 1370 1620 1860 1600 2000 2700 3100 3500 4200 4900 6100 7300 1,78 1,56 1,48 1,39 1,32 1,22 1,1 0,89 0,79 50 51 54 56 57 59 60 61 62 42 42 45 47 47 49 50 51 51 1040 1120 1120 1230 1270 1300 1330 1380 1410 670 670 670 670 670 820 820 820 820 900 1100 1150 1200 1300 1300 1400 1500 1550 520 520 520 520 520 670 670 670 670 390 510 730 860 990 1120 1320 1560 1800 8000 9000 0,67 65 54 1460 1000 1650 820 2120 8800 10000 0,59 67 56 1510 1000 1750 820 2530 10700 12000 0,52 69 57 1620 1000 1850 820 0,48 oil (kg) 0,44 71 A (mm) 73 2930 b59 C1640 D1000 M 2150 p 820 J 3420 G (mm) (mm) 61 1710 (mm) 1300 (mm) 2150 (mm)1070(mm) 4030(mm) 2500 6 3200 18000 21000 0,41 75 62 1790 1300 2250 520 1070 365 4790 90 100380 1950 4 56 680 180 108572015201035125 3150 6 3800 22900 26000 0,37 77 64 2060 1300 2450 1070 5750 90 160520 2550 4 59 860 220 115073016101125125 520 365 4000 7÷8 2800 5240 4 25600 0,3 80 66 2150 1300 2500 520 1070 365 7850 90 200650 6128780 1010300 122581516551170125 250780 6231950 1170290 129084516551170125 5000 7÷8 3500 5780 4 28400 0,27 82 68 2260 1500 2680 520 1250 365 9790 120 315950 3900 4 64 1360330 132087017001215125 670 365 120 RIDOTTE CLASSE 24 kV / REDUCED / LOSSES CLASS 24 670 kV 365 120 400PERDITE 1120 4900 4 65 1500370 129591518701385125 5001290 5500 4 66 1730420 138587018651380125 670 365 120 FI 50 kV BIL Classe Isolamento MT / Insulation Class HV 670 365 130 Livello Isolamento MT / 6500 Rated Voltage HV 67 2100500 24 kV 630 1450 4 142086519951510125 95 kV 8001700 8400 6 68 2340600 181588519851500125 670 365 130 Livello Isolamento BT / 10500 Rated Voltage LV 68 2760 Classe Isolamento BT / Insulation Class LV 820 FI 3 kV 150 1,1 kV 670 185510802135 1000 2000 6 1650 150 365 12502400 13500 6 70 3180 720 187510802135 1650 150 820 365 150 Frequenza / Frequency Regolazione MT / Tappings HV 50÷60 Hz ± 2 x 2,5% 16002800 17000 6 71 3830 920 212011102200 1715 150 820 365 180 20003400 6Pcc73 Pcc 46901090 222513402310 1825 200 1070 365 180 Uk 21000 I0 A B C D Po LwA LpA Kg 220 2500 76 240013802445 1960 200 1070 365 CEI-EN55801320 (120°C) GBE (75°C) KVA 4100 (120°C)26500 6 (mm) (mm) (mm) (mm) (W) 7(W)78 (W) % (dB(A)) (dB(A)) % 33000 31505100 65901480 262014502530 2045 200 1070 365 265 4000* 77701820 281015402530 50 6000 4 38000 270 71400801570 2,50 50 41 1040 2045 670 200 1100 1070 520 365 460 265 5000* 6600 43000 8 81 94802350 303016102620 2135 200 1070 365 265 100 4 360 1600 1750 1,94 51 42 1040 670 1150 520 610 6300* 7300 47000 8 82 115602830 324016702740 2255 200 1070 365 265 160 4 490 2200 2500 1,78 54 45 1250 670 1200 520 870 200 4 590 2600 2980 1,73 56 46 1250 670 1300 520 1010 250 po 4 pcc 660 Uk 3000 57 lwA 3450 Total 1,56 A b47 C1250 D 670 M1300 p 520 J 1170 G oil (75°C) KvA315 (75°C) dB(A) 4170 1,54 59 49 1330 (mm) 820 (mm) 1400 (mm) 670 (mm) 1330(mm) (kg) (kg) (mm) (mm) (mm) (W) 4 (W) 830 % 3700 400 4 970 4400 4900 1,36 60 50 1330 820 1500 670 1570 500 4 1950 1150 4 4900 61 50 1360 820 1550 520 670 365 1850 90 100270 545550 6901,05 180 108572015201035125 160390 576900 8800,97 220 115073016101125125 630 4 2550 1270 4 6100 62 51 1410 820 1650 520 670 365 2130 90 200470 3050 4 59 1030290 122581516551170125 520 365 90 50 6 250 1600 1750 2,16 50 42 1040 670 900 520 430 120 250550 3500 4 60 1190280 129084516551170125 520 365 100 6 340 1800 2050 1,89 51 42 1070 670 1100 520 560 120 315670 4200 4 62 1390320 132087017001215125 670 365 160 6 4900 480 4 2600 1,8 54 45 1250 670 1150 670 520 365 810 120 400790 632900 1530360 129591518701385125 200 6 5700 570 4 3000 1,68 56 47 1250 670 1200 670 520 365 940 120 500950 643350 1770410 138587018651380125 250 1100 6 6500 650 4 3300 1,6 57 47 1250 670 1300 670 520 365 1090 130 630 653800 2140490 142086519951510125 315 1300 6 8400 800 6 4100 1,48 59 49 1330 820 1300 670 670 365 1240 130 800 664650 2390590 181588519851500125 400 6 940 4800 5500 1,33 60 50 1330 820 1400 670 1450 10001450 10500 6 67 2820 660 185510802135 1650 150 820 365 150 500 6 1100 5800 6550 1,08 61 51 1360 820 1500 670 1710 12501750 13500 6 68 3240 710 187510802135 1650 150 820 365 150 630 2200 6 17000 1250 66800 62 51 1410 1715 820 150 1550 820 670 365 1970 180 1600 697600 39100,95 900 212011102200 800 6 1500 8300 9400 0,81 64 53 1570 1000 1700 820 2330180 20002700 21000 6 71 47901070 222513402310 1825 200 1070 365 1000 3200 6 26500 1800 69600 0,72 65 54 1570 1960 1000 200 1750 1070 820 365 2780220 2500 7311000 56901290 240013802445 3150 7513000 67201450 262014502530 1250 3900 6 33000 2100 7 11500 0,63 67 55 1740 2045 1000 200 1950 1070 820 365 3220265 4000* 4600 38000 7 77 79301780 281015402530 2045 200 1070 365 1600 6 2400 14000 16000 0,59 68 55 1740 1000 2200 820 3760265 5000* 5100 43000 8 78 96702300 303016102620 2135 200 1070 365 265 2000 6 3000 16000 18000 0,54 70 57 1860 1300 2250 1070 4430 6300* 5600 47000 8 79 118002770 324016702740 2255 200 1070 365 265 2500 6 3600 20000 23000 0,5 71 58 2010 1300 2300 1070 5270 * solo versione6 con conservatore/NOT provided on hermetically sealed transformers 3150 4300 23500 28000 0,45 74 61 2100 1300 2450 1070 6330 4000 7÷8 5800 26600 29930 0,36 81 67 2260 1300 2500 1070 8630 5000 7÷8 7100 29400 33100 0,32 83 69 2380 1500 2680 1250 10760 Uk 6% TD3R17-TD3R24 (BoBk) TU3O36 - AoBk Uk 4% TR3O36 - CoBk 1600 po 6 pcc 2200Uk 12700 lwA 14500 Total (75°C) KvA (75°C) dB(A) (kg) 2000 (W) 6 (W) 2600 % 16000 18000 dataaccording sheet series CoBk – AoBk Reduced lineTechnical with losses to EN 50541 - 1/2011 PERDITE RIDOTTE CLASSE 12 kV / REDUCED LOSSES CLASS 12 kV Schedaridotte tecnica serie CoBk – AoBk Serie perdite EN 50541 - 1/2011 Norme / Standards IEC 60076 – CEI EN 60076 – DIN EN 60076 – EN 50541-1 Dati e caratteristiche sono indicativi e non impegnativi. La GBE si riserva di comunicare i dati effettivi in fase di offerta. Characteristic are indicative. GBE will confirm actual data at offer/order stage. 19 OTAMB2012 Rev.00 GBE S.p.A. - Via Teonghio n. 44 36040 Orgiano - VICENZA - ITALY Tel. +39 0444 774334 Fax +39 0444 775294 [email protected] www.gbeonline.com 20 Trasformatori in olio distribuzione ed esecuzioni speciali Oil filled transformers for distribution and special applications