Report on bump-bonding in AMS Sezione di Bari • Delivery 9/12/2002: - 1 ladder + 2 singles - reactive ion etching step: oxide developed on surfaces - FE chips came off the detector • Delivery 19/12/2002: - 1 ladder based on non-working components - increased temperature on sensor substrate (from 90 to 100 °C) - increased force applied (from 2500 to 3500 gr) well attached after few minutes, still OK after 2 days, but very weakly attached after 2 weeks V. Manzari, SPD meeting - 4 Feb 2003 FE chip before flip-chip Sezione di Bari From one of the first deliveries V. Manzari, SPD meeting - 4 Feb 2003 FE chip from delivery 19/12/02 Sezione di Bari V. Manzari, SPD meeting - 4 Feb 2003 Sensor from delivery 19/12/02 Sezione di Bari V. Manzari, SPD meeting - 4 Feb 2003 EDX measurements: delivery 19/12/02 Sezione di Bari FE chip Detector V. Manzari, SPD meeting - 4 Feb 2003 Sezione di Bari EDX measurements: from one of the first deliveries FE chip V. Manzari, SPD meeting - 4 Feb 2003 Sensor and FE from delivery 19/12/02 Sezione di Bari Pix 0,0 Chip 5 Pix 32, 255 V. Manzari, SPD meeting - 4 Feb 2003 Sezione di Bari Pix 0,0 Pix 0,up Chip 5 Pix 0,center Pix 0,255 V. Manzari, SPD meeting - 4 Feb 2003 Sezione di Bari Pix 0,0 Pix 0,0 Pix 0,0 Chip 1 Chip 2 Chip 3 Chip 4 Pix 0,0 Chip 5 V. Manzari, SPD meeting - 4 Feb 2003 Sezione di Bari Why there is poor connection between detector and electronics substrates? Some comments: • bump shape has recently been improved • bumps almost pure Indium (no evidence of important O and/or N and/or C contamination) • Thickness of the polyimide layer ( 3.5 mm) • non uniformity of the bump height (8” deposition chain still not operational). • Misalignment of bumps w.r.t. under-bump pads and between detector and FE chip • ………. • Why ATLAS is not affected (2800 pixels/chip, cell size 50mm x 400mm)? V. Manzari, SPD meeting - 4 Feb 2003 Sezione di Bari What next? • Complete SEM and optical microscope investigations of different assemblies (next session at SEM on 6/02): • ALICE • Omega3 • ATLAS (?) • Meeting with AMS next week: What can be done to test and tune the flip-chip procedure. V. Manzari, SPD meeting - 4 Feb 2003