Valvole elettriche Electric valves Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia mod. EV25-C .................................................................................................................... pag. 4 Two ways pilot operated electric valve - cartridge style mod. EV25-C ......................................................................................................................... pag. 4 Valvola elettrica 2 vie unidirezionale pilotata mod. EV25, EV25VE ............................................................................................................................ pag. 5 Two ways pilot operated electric valve mod. EV25, EV25VE ....................................................................................................................................... pag. 5 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia mod. EV40-C .................................................................................................................... pag. 7 Two ways pilot operated electric valve - cartridge style mod. EV40-C ......................................................................................................................... pag. 7 Valvola elettrica 2 vie unidirezionale pilotata mod. EV40, EV40VE ............................................................................................................................ pag. 8 Two ways pilot operated electric valve mod. EV40, EV40VE ....................................................................................................................................... pag. 8 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia mod. EV70-C .................................................................................................................... pag. 10 Two ways pilot operated electric valve - cartridge style mod. EV70-C ......................................................................................................................... pag. 10 Valvola elettrica 2 vie unidirezionale pilotata mod. EV70, EV70VE ........................................................................................................................... pag. 11 Two ways pilot operated electric valve mod. EV70, EV70VE ...................................................................................................................................... pag. 11 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia mod. EV150-C .................................................................................................................. pag. 13 Two ways pilot operated electric valve - cartridge style mod. EV150-C ....................................................................................................................... pag. 13 Valvola elettrica 2 vie unidirezionale pilotata mod. EV150, EV150VE ....................................................................................................................... pag. 14 Two ways pilot operated electric valve mod. EV150, EV150VE .................................................................................................................................... pag. 14 Pubblicazione tecnica di proprietà CBF S.r.l. - Tutti i diritti riservati - Cod. 10/06/2004-DQ13-Rev.02 Technical notes property of CBF S.r.l. - All rights reserved - Cod. 10/06/2004-DQ13-Rev.02 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Gli ordini devono essere inviati alla: Ordinazioni CBF S.r.l. Via Caboto, 1 36075 Montecchio Maggiore (VI) Tel. 0444 499141-3 Fax 0444 499145 Per posta o telefax. Si prega di evitare, ove possibile, di effettuare ordini per telefono dato che questi dovranno essere in ogni caso confermati per lettera o fax. Gli ordini devono chiaramente indicare: • • • • • • • • Esatta ragione sociale o indirizzo completo del richiedente. Numero dʼordine. Data dʼordine. Numero dʼofferta CBF (qualora esista). Denominazione valvola. Data consegna richiesta. Destinazione merce. Vettore. • La CBF S.r.l. garantisce che i suoi prodotti sono esenti da difetti di materiali o di costruzione per un periodo di 12 mesi a partire dalla data di spedizione dai propri magazzini in Montecchio Maggiore (VI) - Italia. La garanzia è esclusivamente limitata alla riparazione o sostituzione, a giudizio della CBF S.r.l., dʼogni parte o parti difettose in materiale o costruzione, previo esame dei pezzi che devono essere ritornati alla CBF, franco destino, corredati di descrizione dettagliata del malfunzionamento. CBF declina ogni responsabilità ed esclude lʼapplicazione della garanzia per quei prodotti che, a proprio insindacabile giudizio, siano stati contaminati, impiegati erroneamente o manomessi in circostanze al di fuori del proprio controllo o senza autorizzazione. La garanzia decade qualora siano apportate modifiche a circuiti o impianti tali da influenzare negativamente il funzionamento del prodotto CBF. In nessun caso una rivalsa in garanzia potrà comportare revoche contrattuali, sospensioni anche parziali di pagamenti, compensi per danni o rimborsi spese, ivi compresa la spesa di manodopera per la sostituzione del pezzo. Questa garanzia riconosciuta dalla CBF S.r.l. attraverso la propria organizzazione assistenziale esclude e sostituisce ogni altra garanzia di qualsiasi genere. CBF S.r.l. non è responsabile per danni diretti o indiretti, ivi comprese eventuali perdite economiche conseguenti a fermo macchina, o ritardate consegne di qualsiasi genere. • • • • • Garanzia Responsabilità dʼuso. Tutti i prodotti CBF sono sottoposti a rigorosi collaudi funzionali, conformemente alle caratteristiche riportate sulla documentazione tecnica CBF. Dal momento che le reali condizioni di funzionamento delle apparecchiature del Compratore non sono riproducibili integralmente nei laboratori della CBF, la responsabilità della scelta e lʼidoneità dei prodotti sono a carico del Compratore stesso. Giurisdizione In caso di contestazione in cui la CBF S.r.l. sia convenuta è esclusivamente competente il Foro di Vicenza. Le tratte, le accettazioni di regolamenti, le spedizioni senza o contrassegno, le esazioni per mezzo dʼincaricati, non costituiscono deroga a questa clausola anche nel caso in cui la CBF S.r.l. fosse ricercata per connessione o continenza di causa. Quando la CBF S.r.l. sia attrice potrà ricorrere sia al Foro di Vicenza, sia a quello di residenza del convenuto. 2 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Orders are received by: Order entry procedure. CBF S.r.l. Via Caboto, 1 36075 Montecchio Maggiore (VI) Tel. ++39-0444-499141/3 Fax ++39-0444-499145 By mail or telefax. When possible, please avoid sending orders by telephone since you must later confirm them by letter. Orders must clearly show: • • • • • • • • The corporate name and the full address of the applicant. Order number. Order date. CBFʼs offer number (when existing). Valve denomination. Required delivery date. Goods destination. Carrier. • CBF S.r.l. warrants that its products are free from defects in material and workmanship for a period of 12 months from the date of shipment from the factory in Montecchio Maggiore (VI) - Italy. The warranty is strictly limited to the repair or replacement (at CBF S.r.l. option) of any part or parts defective in material or workmanship, subjet to CBFʼs examination of the part which must be returned to CBF S.r.l., carriage pre-paid by the Customer, with a detailed description of the malfunction. CBF S.r.l. shall not be responsible for circumstances beyond its control and this warranty shall not apply to products which, in the sole judgement of CBF have been subjected to contamination, tampering, negligent handling, misapplication or other misuse. Changes in circuit or changes in other components which may adversely affect the products of CBF S.r.l. void this warranty. In none of the cases quoted in the above paragraphs can the customer claim the cancellation of the contract compensation for damages or reimbursement of any expenses as, for example, labor required to replace the defective parts. This warranty recognized by CBF S.r.l. through its service organization is expressly in lieu of and excludes and supersedes any warranty of merchantability or fitness. CBF S.r.l. makes no other warranties, expressed or implied, and is not responsible for any consequential damages resulting from use by any buyer or user, its liability being limited to the value of product sold or to the obligation to replace a defective part. In no event shall CBF S.r.l. be liable for loss of anticipated profits, consequential damages, or loss of any equipment, installation, system operation or service into which the products of CBF S.r.l. may be fitted. CBF S.r.l. shall not be liable for any default, claimed breach of warranty, failure to deliver or otherwise, except as herein specifically indicated. • • • • • Warranty Responsibility for use. All CBF products are checked and tested, in accordance with the specifications indicated in the relevant technical documents. Since the actual installation and performance of the Customerʼs equipment cannot be exactly reproduced in the CBF testing laboratories, the assurance of suitability of all CBFʼs products in the Customer application is the responsibility of the Customer himself. Jurisdiction In case of a dispute where CBF S.r.l. is summoned before court, the Court in Law in Vicenza (Italy) is exclusively competent: drafts, acceptance of settlements, dispstches without or with C.O.D. do not constitute a derogation from this clause of jurisdiction even in case CBF S.r.l. should be pursued for concession or continence of cause. When CBF S.r.l. is the plaitiff, it will be able to recur both to Court of Law in Vicenza and to that where the other party resides. Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 3 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia Two ways pilot operated electric valve - cartridge style mod. EV25 -C Funzioni possibili con solenoide: Operating features with solenoid: Schema Symbol Cod. diseccitato de-energized A A P A B P eccitato energized P A P A A P A P P A P A A P A P 18 Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. 15 12 P All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. The specifications are not binding, CBF reserves the right to introduce modifications without notice. A + filtro 6 P A 3 12 Schema - Symbol 16 20 16 20 Portata - Flow Q(l/min) A 39 8 Close 87 Open Schema - Symbol ch. 24 Coppia 45Nm Torque 45Nm B 300µ Close Open Ø 28 4 8 Pressione di lavoro max Max working pressure bar Modello EV25-C Type EV25-C Schema - Symbol A 250 Schema - Symbol B 210 12 16 20 15° EV25-C - A Schema: A, B Symbol: A, B 4 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 3/4"UNF-16 Ø 12,7H7 Portata max Max flow l / min Sigla di ordinazione / Ordering code Modello / Type Ø 20,6 Portata - Flow Q(l/min) 25 A 0 +0,1 8 0 P 12,5 12 17 8 13 4 28 0 2,5 80 60 40 20 0 4 19,5 80 60 40 20 0 0 29 Tempo di risposta - Response time (ms) 0 7 9 17,5 Pressione - Pressure ∆p(bar) Schema idraulico / Hydraulic scheme CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata con o senza vite di emergenza Two ways pilot operated electric valve with or without emergency screw mod. EV25 / EV25VE Cod. Schema Symbol A A P A B P Funzioni possibili con solenoide: Operating features with solenoid: diseccitato de-energized eccitato energized P A P A A P A P P A P A A P A P Pressione - Pressure ∆p(bar) Schema idraulico / Hydraulic scheme 18 Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. 15 12 9 P A + filtro 6 P A 3 Tempo di risposta - Response time (ms) 0 80 60 40 20 0 80 60 40 20 0 0 4 8 12 Schema - Symbol 4 8 12 20 16 20 B Close Open 4 16 A Schema - Symbol 0 20 Close Open 0 16 Portata - Flow Q(l/min) 8 Modello Type P A EV25 - 14 / EV25 - 14 - VE 1/4" gas EV25 - 38 / EV25 - 38 - VE 3/8" gas 12 Portata - Flow Q(l/min) Pressione di lavoro max Max working pressure bar Portata max Max flow l / min 250 25 Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 5 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 108,5 58,5 Disegni / Drawings ch. 24 12,5 Coppia 45Nm Torque 45Nm P 23,5 50 Ø 6,5 A Vite emergenza Emergency screw 30 6 ch. 4 17 44 50 Sigla di ordinazione / Ordering code EV25 - 14 - A - VE Modello / Type I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. The specifications are not binding, CBF reserves the right to introduce modifications without notice. 6 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 ch. 13 6 12 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia Two ways pilot operated electric valve - cartridge style mod. EV40 -C Funzioni possibili con solenoide: Operating features with solenoid: Schema Symbol Cod. diseccitato de-energized eccitato energized P A P A A P A P A A P A B P A 20 P 8 P A 4 10 20 30 Schema - Symbol 40 45 A P A A P A P 40 45 A Close Open 0 10 20 30 Schema - Symbol ch. 24 B Coppia 45Nm Torque 45Nm Close A B Schema - Symbol M 40 Pressione di lavoro max Max working pressure bar Portata max Max flow l / min 300 45 Sigla di ordinazione / Ordering code EV40-C - A Modello / Type 45 Portata - Flow Q(l/min) Ø 37 Ø 28 0 Ø 20,6+0,1 15° 3/4"UNF-16 Ø 12,7H7 19,5 Schema - Symbol Schema - Symbol 30 29 Modello EV40-C Type EV40-C 20 17 10 17,5 0 27,5 Open 8 80 60 40 20 0 P Portata - Flow Q(l/min) 12,5 Tempo di risposta - Response time (ms) 150 120 90 60 30 0 0 P 102 0 A A 7 A P P Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. The specifications are not binding, CBF reserves the right to introduce modifications without notice. 16 12 P A 2,5 Pressione - Pressure ∆p(bar) M P A Schema: A, B, M Symbol: A, B, M Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 7 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata con o senza vite di emergenza Two ways pilot operated electric valve with or without emergency screw mod. EV40 / EV40VE Cod. Schema Symbol A A P A B P Funzioni possibili con solenoide: Operating features with solenoid: diseccitato de-energized eccitato energized P A P A A P A P P A P A A P A P Pressione - Pressure ∆p(bar) Schema idraulico / Hydraulic scheme 20 Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. 16 12 A P 8 P A 4 0 10 20 Tempo di risposta - Response time 80 60 40 20 0 30 Schema - Symbol (ms) 150 120 90 60 30 0 0 40 45 40 45 40 45 Portata - Flow Q(l/min) A Close Open 0 10 20 30 Schema - Symbol B Close Open 0 10 20 Modello Type P A EV40 - 38 / EV40 - 38 - VE 3/8" gas EV40 - 12 / EV40 - 12 - VE 1/2" gas 30 Portata - Flow Q(l/min) Pressione di lavoro max Max working pressure bar Portata max Max flow l / min 300 45 8 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 74,5 Disegni / Drawings 15 134,5 ch. 24 Coppia 45Nm Torque 45Nm P 23,5 60 Ø 6,5 A 30 6 Vite emergenza Emergency screw 18 44 50 Sigla di ordinazione / Ordering code EV40 - 12 - B - VE Modello / Type I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. The specifications are not binding, CBF reserves the right to introduce modifications without notice. Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 9 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia Two ways pilot operated electric valve - cartridge style mod. EV70 -C Schema Symbol Cod. Funzioni possibili con solenoide: Operating features with solenoid: A A P A B P A 12 4 A P 15 30 45 Schema - Symbol A A P A P P A P A A P A P P A P A A P A P 60 75 60 75 Portata - Flow Q(l/min) A Close Open 0 15 30 45 Schema - Symbol B ch. 32 Coppia 45Nm Torque 45Nm Close Open Ø 37 A B 60 75 Portata - Flow Q(l/min) Pressione di lavoro max Max working pressure bar Portata max Max flow l / min 300 70 2° Ø 35 0 Ø 27 +0,1 3/4"BSPP 42 Schema - Symbol Schema - Symbol 45 Sigla di ordinazione / Ordering code EV70-C - A Ø 15 Ø 23,5H7 Modello / Type Schema: A, B, M Symbol: A, B, M 10 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 29 Modello EV70-C Type EV70-C 30 30,5 15 16 0 17,5 180 150 120 90 60 30 0 0 P 37,5 180 150 120 90 60 30 0 A A 3,5 (ms) 0 Tempo di risposta - Response time P P Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. The specifications are not binding, CBF reserves the right to introduce modifications without notice. 16 8 P eccitato energized 105 Pressione - Pressure ∆p(bar) M diseccitato de-energized CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata con o senza vite di emergenza Two ways pilot operated electric valve with or without emergency screw mod. EV70 / EV70VE Cod. Schema Symbol A A P A B P Funzioni possibili con solenoide: Operating features with solenoid: diseccitato de-energized eccitato energized P A P A A P A P P A P A A P A P Pressione - Pressure ∆p(bar) Schema idraulico / Hydraulic scheme 12 (ms) P 8 4 0 Tempo di risposta - Response time Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. 16 180 150 120 90 60 30 0 180 150 120 90 60 30 0 A 0 A P 15 30 45 Schema - Symbol 60 75 60 75 60 75 Portata - Flow Q(l/min) A Close Open 0 15 30 45 Schema - Symbol B Close Open 0 15 30 Modello Type P A EV70 - 12 / EV70 - 12 - VE 1/2" gas EV70 - 34 / EV70 - 34 - VE 3/4" gas 45 Portata - Flow Q(l/min) Pressione di lavoro max Max working pressure bar Portata max Max flow l / min 300 70 Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 11 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 67 Disegni / Drawings Coppia 45Nm Torque 45Nm ch. 32 P ch. 4 6 40 59 ch. 13 65 Ø 6,5 Vite emergenza Emergency screw 9 A 39 Ø 37 40 74 80 Sigla di ordinazione / Ordering code EV70 - 12 - A - VE Modello / Type I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. The specifications are not binding, CBF reserves the right to introduce modifications without notice. 12 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata - a cartuccia Two ways pilot operated electric valve - cartridge style mod. EV150 -C Cod. Schema Symbol Funzioni possibili con solenoide: Operating features with solenoid: A A P A B P A 16 12 A 4 70 105 Schema - Symbol 140 175 140 175 P A A P A P P A P A A P A P P A P A A P A P Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. The specifications are not binding, CBF reserves the right to introduce modifications without notice. Portata - Flow Q(l/min) Ø 37 A Close Open 0 35 70 105 Schema - Symbol ch. 38 Coppia 50Nm Torque 50Nm B Close 48 P Open 35 70 105 140 175 Portata - Flow Q(l/min) 4° A B Schema - Symbol M Portata max Max flow l / min 300 150 Ø 34,7 1" BSPP 39 Schema - Symbol Schema - Symbol Pressione di lavoro max Max working pressure bar 0 +0,1 17 Modello EV150-C Type EV150-C A Ø 44 41 0 52 180 150 120 90 60 30 0 35 A 121 180 150 120 90 60 30 0 0 P P 18 (ms) A 8 0 Tempo di risposta - Response time P P eccitato energized 3 Pressione - Pressure ∆p(bar) M diseccitato de-energized Sigla di ordinazione / Ordering code EV150-C - A Modello / Type Schema: A, B, M Symbol: A, B, M Ø 22 Ø 30 H7 Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 13 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Valvola elettrica 2 vie unidirezionale pilotata con o senza vite di emergenza Two ways pilot operated electric valve with or without emergency screw mod. EV150 / EV150VE Cod. Schema Symbol A A P A B P Funzioni possibili con solenoide: Operating features with solenoid: diseccitato de-energized eccitato energized P A P A A P A P P A P A A P A P Pressione - Pressure ∆p(bar) Schema idraulico / Hydraulic scheme 16 12 (ms) Tutti i dati forniti sono stati ottenuti usando olio con viscosità di circa 30cSt a 50°C. Campo di temperatura ammesso: -20°C, +90°C. Filtrazione assoluta: 25µ. All performances and calibrations are carried out by using hydraulic oil with viscosity approx. 30cSt at 50°C. Temperature range: -20°C, +90°C. Filtration absolute: 25µ. A 8 A 4 0 Tempo di risposta - Response time P 180 150 120 90 60 30 0 180 150 120 90 60 30 0 0 35 70 P 105 Schema - Symbol 140 175 140 175 140 175 Portata - Flow Q(l/min) A Close Open 0 35 70 105 Schema - Symbol B Close Open 0 35 70 Modello Type P A EV150 - 34 / EV150 - 34 - VE 3/4" gas EV150 - 10 / EV150 - 10 - VE 1" gas 105 Portata - Flow Q(l/min) Pressione di lavoro max Max working pressure bar Portata max Max flow l / min 300 150 14 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 Disegni / Drawings Ø 37 72,5 ch. 38 Coppia 50Nm Torque 50Nm Ø 8,5 72,5 ch. 13 ch. 4 49 80 P Vite emergenza Emergency screw A 43 82,5 50 7,5 9 90 Sigla di ordinazione / Ordering code EV150 - 34 - B - VE Modello / Type I dati non sono impegnativi, CBF si riserva di apportare modifiche senza preavviso. The specifications are not binding, CBF reserves the right to introduce modifications without notice. Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02 - 15 CBF S.r.l. - Via Caboto, 1 - 36075 Montecchio Maggiore (VI) Tel. 0444 499141 / 0444 499143 - Fax 0444 499145 16 - Pubblicazione tecnica - Technical notes cod. 10/06/2004-DQ13-Rev.02