CLIL Activity – I.T.I.S. “C. Zuccante” 5ISB – School Year 2005/06 STRUCTURED CABLING Final Exam Compendium A. Memo Brain storm What’s structured cabling? What’s the meaning of “structured”? What’s the meaning of “standardisation”? Is my house cabled? Where, when and how was cabled? Why the law covers the structured cabling problem? Objectives Structured cabling systems Terminology Passive Devices Cross Connect technology for the final exam 1. 2. 3. 4. I. Documentation II. Installation technique III.Mini-glossary Structured Cabling Systems Structured cabling is a method for creating an organized cabling system that can be easily understood by installers , network administrators technicians , and any other that deal with cables Structured Cabling Systems Rules of Structured Cabling for LANs look for a complete connectivity solution plan for future growth maintain freedom of choice in vendors Subsystems of Structured Cabling Backbone Pathway Horizontal Pathway Antenna Entrance Telecommunications Room/Closet Tie Pathway Telecommunications Room/Closet Equipment Room/Closet Backbone Pathways Horizontal Pathway Entrance Room/Closet Main Terminal Space (Entrance Facility) Interbuilding Backbone Alternate Entrance Demarcation Point Telecommunications Outlet Work Area Subsystems of Structured Cabling Demarcation Point punto di demarcazione dorsale tra edifici Interbuilding Backbone accesso alternativo Alternate Entrance between outside service provider cables and customer cables Subsystems of Structured Cabling presa di rete Telecommunications Outlet Work Area area di lavoro Subsystems of Structured Cabling stanza dei dispositivi Equipment Room/Closet canalizzazione orizzontale o di piano Horizontal Pathway Entrance Room / Closet Main Terminal Space (Entrance Facility) stanza / armadio d’accesso principale (interconnessione interbuilding-intrabuilding) Telecommunications Room/Closet stanza / armadio di permutazione di piano Subsystems of Structured Cabling Tie Pathway canala passacavi Backbone Pathway canalizzazione di dorsale o canalizzazione verticale o canalizzazione di edificio Backbone Pathways Subsystems of Structured Cabling Antenna Entrance ingresso d’antenna Subsystems of Structured Cabling other diagram example ? ? ? ? ? Subsystems of Structured Cabling a larger example Horizontal Cabling Building A Telecommunication Outlet Floor Distributor / Telecommunication Closet Building Distributor / Telecommunication Closet campus comprensorio Building C Building B Building Backbone Campus Backbone Campus Distributor / Telecommunication Closet Cabling logical diagram Campus Distributor / Main cross Connect Campus Backbone Building Distributor / Intermediate cross Connect Building backbone or vertical cabling Floor Distributor / Horizontal cross Connect Telecommunication Closets horizontal cabling Telecommunication Outlets optional cabling (not allowed) optional Transition Point Campus Equipment Room more complex than Telecommunication Closet Tie Pathway for cables to electronic devices Cables from Service Provider Electronic Devices to Building Distributor / Intermediate cross Connect Main cross Connect Demarcation Point plywood panel Telecommunications Room Patch Panel (front) Distribution Rack Telecommunication Closet Raceways A raceway is a channel that contains cables. Raceways include common electrical conduits , specialized cable trays or ladder racks , in-floor duct systems and plastic or metal surface mounted raceways. , Patch Panel Patch panel and Patch Cord Panel for UTP Panel with telephonic cross-connect cables with 16 RJ45 Panel for optical fiber with 16 SC Optical Patch Cord Patch Cord connectors Patch panel and Patch Cord Data Voice Telecommunication Telecommunication Closet Outlet Horizontal Cabling Telecommunications Closet Work Area I1 horizontal cabling 90 m I2 I3 HC I1 + I2 + I3 = 10 m = cross-connect I1 = work area cable = telecommunication outlet I2 = patch cord = transition point I3 = equipment cable Telecommunication Outlet four pairs cable directly connected on RJ45 socket four pairs cable connected on plug RJ45 adapter Working Area • work area • at least two outlet • about 10 m2 • patch • max 90 m Work Area Cable RJ45: socket and plug RJ45 Wall Socket (receptacle ) or Telecommunication Outlet jack RJ45 or plug (male) TIA/EIA Standard ALTERNATE (T568A) PREFER (T568B) PAIR 2 PAIR 3 PAIR 3 1 2 W G G PAIR 1 PAIR 4 3 4 5 6 7 8 W BL W O W BR O BL BR JACK POSITIONS PAIR 2 1 2 W O O PAIR 1 PAIR 4 3 4 5 6 7 8 W BL W G W BR G BL BR JACK POSITIONS UTP cable Pair 1 Blue/White 2 Orange/White 3 Green/White 4 Brown/White Wire White/Blue Blue White/Orange Orange White/Green Green White/Brown Brown The solid colored wire is called “ring” Language Tip: and the stripe wire is called "tip". colour (UK) or color (USA) for the final exam Documentation: how to describe the structured cabling for the assigned network design Installation technique: UTP cat. 5 installation: do and don’t making a UTP patch cable Mini-glossary Vocabulary Document: 1. Topology FIRST FLOOR SERVIZI ACCOGLIENZA VANO SCALE SECOND FLOOR UFFICI BIBLIOTECA SALA MACCHINE MAGAZZINI DI CONSERVAZIONE VANO SCALE SALA CONSULTAZIONE SALA PRESTITI SALA WIRELESS THIRD FLOOR UFFICI O AMMINISTRATIVO UFFICIO PERSONALE UFFICIO TECNICO DIRIGENTE VANO SCALE UFFICIO ACQUISTI Document: 2. Cabling layout PIANO TERRA EF PRIMO PIANO TC01 EF MC TC11 UFFICI BIBLIOTECA SALA MACCHINE MC SERVIZI TC21 ACCOGLIENZA VANO SCALE TC03 TC12 VANO SCALE TC02 SALA CONSULTAZIONE SALA PRESTITI SALA WIRELESS MAGAZZINI DI CONSERVAZIONE TC01 MC LEGENDA MC Main cross Connect EF Entrance Facility TC01 Telecommunication Closet PT (Prestiti+Accoglienza) TC02 Telecommunication Closet PT (Wireless) TC03 Telecommunication Closet PT (Consultazione) TC11 Telecommunication Closet PP (Biblioteca) TC12 Telecommunication Closet PP (Magazzino) TC21 Telecommunication Closet SP (all the Officies) Backbone Pathway Horizontal Pathway MC SECONDO PIANO TC21 UFFICI O AMMINISTRATIVO UFFICIO PERSONALE UFFICIO TECNICO DIRIGENTE VANO SCALE UFFICIO ACQUISTI Document: 3. Logic Diagram EF MC TC01 TC02 TC11 TC03 TC12 TC21 TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx TOxx Documentation: alternative view Document: 4. Media 5. Connectors MEDIA from from from from from from from EF MC MC MC TC01 TC01 TCxx to to to to to to to MC TC01 TC21 TC1x TC02 TC03 TOxx multimodal optical fiber multimodal optical fiber multimodal optical fiber UTP cable, cat.5 UTP cable, cat.5 UTP cable, cat.5 UTP cable, cat.5 CONNECTORS Optical Fiber: ST UTP: RJ45 (TIA 568B) Document: 6. Telecommunication Closet third floor TC21 FO link SW 21 second floor MC TC11 TC12 modem SW 11 SW 12 FO link PP 11 PP 12 PP 21 router SW P SW CS TC01 TC02 TC03 FO link SW 02 SW 03 SW 01 PP 02 PP 03 PP 01 PP CS first floor Document: 7. Cross Connection position connection patch PP CS-1 EF modem PP CS-2 PP 01-1 SW CS-1 uplink to SW01 PP CS-3 PP 01-2 SW CS-2 uplink to SW02 PP CS-4 PP 01-3 SW CS-3 uplink to SW03 PP CS-5 PP 01-4 SW CS-4 uplink to SW04 …… …… PP CS-xx TOxx ---- modem ---- router …… description ISP connection …… SW CS-xx to a Telcom. Outlet router patch from modem to router SW CS-yy patch from router to switch Document: second floor LEGEND optical fiber (802.3 ab) UTP (802.3 ab, Gigabit) UTP (802.3u Fast Ethernet) legacy (USB, Lpt, Com) wireless 8. LAN Diagram UP SW 21 FO prt uff TLC router modem Uff. biblio. SW 11 UP SW CS FO uff FO bibli bibli SW P dirig prn scan Magazzino server UP SW 12 mag Sala prest. mag Sala ric. Sala cons. SW 01 UP SW 02 UP SW 03 FO pres prn pres prt uff prn mob Atrio self self pres AP mob pres pres UP Document: 9. Active Devices Specifications Document: 10. IP address Installation technique CAT.5 installation: do and don’t Please, note the relation between Categories (USA) and Classes (Europe) for UTP cable: class A category - B - C 3 D 5e E 6 CAT.5 Installation CABLE TENSION DON’T pull cable with excessive force, as this will alter the cable’s insulation and transmission properties. DO pull cable using less than 25 pounds (11,3 Kg) of pullforce. UNROLLING CABLE DON’T allow the cable to kink, knot or snag while pulling it off the spool or out of the box; deforming the pair-twist will alter the performance of the cable. DO use a cable pulling accessory. CAT.5 Installation RUNNING & SUPPORTING CABLE DON’T overstress cables by overloading …. … and DON’T allow the cable hook to rip or fray the cable. minimum distance between power supply cable and network cable (parallel running) is 15 cm. DO use j-hooks or similar devices designed to support cables. CAT.5 Installation RUNNING & SECURING CABLE DON’T overstress cables by overtightering cable ties, especially to the point where crush stress is visible. DO use tie wraps loosely on large bundles. (see also “Using Tie-wraps”) DO use Velcro tie wraps to secure large bundles. USING WIRE CHANNELS DON’T allow the cable to form right angles or sharp bends. DO use sweeping bends. DO use cable clamps on individual runs. CAT.5 Installation STAPLING CABLE DON’T squish cables when securing them. DO staple by hand, or use staplers with depth stops. DO use Velcro to keep cables from becoming over-cinched. USING TIE-WRAPS DON’T chinch the cables tightly, especially to the point where crush stress is visible. DO tie-wrap the bundle loosely. DO use Velcro as a flexible and reusable alternative to plastic tie-wraps to keep bundles from cinching. CAT.5 Installation REMOVING CABLE JACKET DON’T remove too much cable jacket. DO retain cable jacket as close to the termination point as possible. MAINTAINING PAIR TWISTS DURING TERMINATION DON’T untwist the cable pairs more than 12 mm and DON’T strip cable jacket back any more than you need to. DO maintain pair twists to within 12 mm of the termination point, and the cable jacket is maintained as close to the terminations as possible. Making a UTP patch cable 1. Strip off the jacket for about 2,5 cm. 2. Separate out the 4 pairs of wires 3. Untwist and organize the wires according to the proper colour code and flatten the wires (T568A or T568B). 4. Maintain the colour order and flatness of the wires, then clip their length so that a maximum of 1.2 cm of untwisted wire is present. Making a UTP patch cable 5. 6. 7. 8. Insert ordered wires into RJ-45 plug; make sure jackets are inserted into plug. Push the wires in firmly enough to make sure the conductors are all visible when you look at the plug from the end. Inspect the colour code and jacket location to be sure they are correct. Insert the plug firmly into the crimp tool and crimp down completely. Fiber Optic connectors Mini-Glossary Vocabulary ST (Straight Tip) A fiber-optic connector which uses the bayonet style coupling. SC type of fiber optic connector (Structured Connector) optical connector with a push-pull mating design. Commonly referred to as Structured Connectors or Stick and Click. UTP (Unshielded Twisted Pair) a cable that consists of two or more insulated conductors in which each pair of conductors are twisted around each other. RJ45 Registered Jack-45, a telephone connector that holds up to eight wires, used in Ethernet devices T568A/B color coding used for normal network cabling Vocabulary OSI Open Systems Interconnection, the 7-layers suite of protocols designed by ISO committees to be the international standard computer network architecture MDF Main Distribution frame, a distribution frame on one part of which terminate the permanent outside lines entering the central office building and on another part of which terminate the subscriber line multiple cabling, trunk multiple cabling, etc. MMF Multimode Fiberoptic Cable, fiberoptic cable in which the signal or light propagates in multiple modes or paths Vocabulary 10Base-T An Institute of Electrical & Electronic Engineers (IEEE) 802.3 working group designing a specification for 10 Mbps CSMA/CD baseband local area networking (LAN) transmission commonly called Ethernet over twisted-pair wiring. 100Base-T A specification for 100 Mbps - commonly called Fast Ethernet over twisted-pair wiring. 1000Base-T A IEEE 802.3z working group designing a specification for 1000 Mbps - commonly called Gigabit Ethernet. wiring diagram A point to point, highway or airline wiring format which defines the wiring path and color code of wire to and from apparatus components. Vocabulary wire A single metallic conductor, usually solid-drawn and circular in cross section shielded cable Cable with metal tape shield wrapped around the insulated conductors. twisted pair Insulated wire in which pairs are twisted together. rack A structure on which equipment is mounted patch panel A generic device that allows for organizing and connecting the copper and fiber optic cables power cord A three-wire (sometimes two-wire) cord used to make connection with an AC public power supply Vocabulary layout A proposed or actual arrangement or allocation of equipment ground An intentional or accidental connection between an electric circuit or its housing and the ground (earth) fiber optics Thin filaments of glass through which light beams are transmitted over long distances and which can carry enormous amounts of data cable A single wire or group of individual wires in a single sheath cable riser Cable running vertically in a multi-story building to serve the upper floors. Vocabulary cable run Conduit used to run cables through a building. Also the path taken by a cable or group of cables. cable tray Steel trough erected above equipment racks to support cable runs in an equipment room conduit A device used to hold, organize, and protect electrical or optical cables cross connection - A mapping between two channels or paths at a network device backbone The main connectivity device of a distributed system. All systems that have connectivity to the backbone connect to each other antenna A device for transmitting or receiving, or transmitting and receiving signals Vocabulary structured cabling cable pathway cable runway closet demarcation point is a set of standards that determine how to wire a building for data or voice communications systems providing horizontal, vertical and backbone pathways from your data room to your workstations o Ladder Rack, horizontal, vertical and backbone pathways for your computer room, telecommunications room and data center a cabinet or enclosed recess for telecommunications devices the location within a building where the lines from the telephone company connect to the customer's lines. Vocabulary interbuilding intrabuilding outlet telecommunication outlet jack horizonthal pathway entrance facility Vocabulary building backbone campus backbone building distributor floor distributor campus distributor cross connect main cross connect Vocabulary intermediate cross connect transition point patch cord