Modelli disponibili / Available models EVF Controllori a 4 uscite digitali / Four digital outputs controllers Codice / Code Ever y Control Group Descrizione / Description Alimentazione 115...230VAC,buzzer di allarme,sonda cella,sonda evaporatore e sonda condensatore NTC,relè compressore da 30A res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS EVF204N9 Power supply 115... 230 VAC, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated 30 res.A @ 250VAC,TTL serial port with MODBUS communication protocol th Controllori digitali per vetrine frigorifere,composti da interfaccia utente con tasti a sfioramento di tipo capacitivo (integrabile nell'unità) e da modulo di controllo Digital controllers for refrigerated showcases, made of user interface with capacitive "push buttons" (that can be integrated in the unit) and of control module Alimentazione 115... 230 VAC, orologio, buzzer di allarme, sonda cella, sonda evaporatore e sonda condensatore NTC, relè compressore da 30A res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS EVF214N9 Power supply 115... 230VAC, real time clock, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated 30 res.A @ 250VAC,TTL serial port with MODBUS communication protocol Controllori a 5 uscite digitali / Five digital outputs controllers Codice / Code Descrizione / Description Alimentazione 115...230VAC,buzzer di allarme,sonda cella,sonda evaporatore e sonda condensatore NTC,relè compressore da 30A res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS EVF205N9 Power supply 115... 230 VAC, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated 30 res.A @ 250VAC,TTL serial port with MODBUS communication protocol Alimentazione 115... 230 VAC, orologio, buzzer di allarme, sonda cella, sonda evaporatore e sonda condensatore NTC, relè compressore da 30A res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS EVF215N9 Power supply 115... 230VAC, real time clock, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated 30 res.A @ 250VAC,TTL serial port with MODBUS communication protocol Per altri modelli,contattare la rete vendita Evco all’indirizzo [email protected] / For further models,please contact the Evco sales network at the address [email protected]. Accessori / Accessories Codice / Code Descrizione / Description Chiave di programmazione EVKEY Programming key Interfaccia serialeTTL / RS-485 non isolata EVIF20TSX Not insulatedTTL / RS-485 serial interface Dispositivo per la registrazione di dati, per il download di dati registrati (via USB) e per l'upload / download di parametri di configurazione EVUSBREC01 Device for the data recording, for the data download (via USB) and for the upload / download of configuration parameters Organizzazione con Sistema di Gestione certificato / Company with Management System certified Evco si riserva il diritto di apportare qualsiasi modifica senza preavviso e in qualsiasi momento senza pregiudicare le caratteristiche essenziali di funzionalità e sicurezza / Evco reserves the right to make any change without prior notice and at any time without prejudice the basic safety and operating features. EVCO S.p.A. Via Mezzaterra 6, 32036 Sedico Belluno ITALY • Phone +39 0437 852468 • Fax +39 0437 83648 • [email protected] • www.evco.it ISO 9001:2000 118EVF2A00 EVF è una serie di controllori digitali studiati per la gestione di vetrine refrigerate a temperatura normale o a bassa temperatura il cui design e la cui facilità di pulizia ricoprono un ruolo importante. La serie è composta da 4 strumenti:EVF204,EVF214,EVF205 ed EVF215. Gli strumenti dispongono di: orologio (solo nell'EVF214 e nell'EVF215) buzzer di allarme (incorporato nell'interfaccia utente) 3 ingressi analogici (sonda cella,sonda evaporatore e sonda condensatore) per sonde NTC 2 ingressi digitali (micro porta e multifunzione) 5 uscite digitali (relè elettromeccanici, 4 nell'EVF204 e nell'EVF214) di cui 1 da 30 A res. @ 250 VAC per la gestione del compressore, 2 da 16 A res. @ 250 VAC per la gestione dello sbrinamento e di una quarta utenza (impostabile per luce della cella, resistenze antiappannamento, uscita ausiliaria, uscita di allarme, resistenze della porta, valvola dell'evaporatore o ventilatore del condensatore) e 2 da 8 A res. @ 250VAC per la gestione del ventilatore dell'evaporatore e di una quinta utenza (quest'ultima solo nell'EVF205, nell'EVF215 e impostabile allo stesso modo della quarta); lo sbrinamento può essere di tipo elettrico o a gas caldo porta seriale con protocollo di comunicazione MODBUS. Il dispositivo è disponibile in esecuzione "splittata" (interfaccia utente + modulo di controllo). L'interfaccia utente si presenta dietro una lastra di metacrilato ed è composta da un display custom da 4 digit (con icone funzione) e da 6 tasti a sfioramento di tipo capacitivo (set,up,down, sbrinamento, luce cella e on/stand-by); l'installazione è prevista a retro pannello, con biadesivo, per la sua completa integrazione meccanica ed estetica nella vetrina. Il modulo di controllo si presenta in scheda a giorno;l'installazione è prevista su superficie piana, con distanziali. Attraverso l'orologio è possibile programmare fino a 6 orari giornalieri di attivazione dello sbrinamento e 1 orario giornaliero di attivazione di attivazione della funzione “Energy Saving”; la funzione “Energy Saving” viene attivata anche automaticamente, in assenza di attivazioni dell’ingresso micro porta. Attraverso la funzione "HACCP" è possibile memorizzare fino a 9 eventi (3 nell'EVF204 e nell'EVF205) per ognuno dei 4 allarmi HACCP (allarme di temperatura di minima, allarme di temperatura di massima, allarme ingresso micro porta e allarme interruzione dell’alimentazione, quest'ultimo solo nell'EVF214 e nell'EVF215); per ogni allarme HACCP è possibile memorizzare il valore critico, la data e l’ora in cui l’allarme si è manifestato (queste ultime due solo nell'EVF214 e nell'EVF215) e la durata. Attraverso la chiave di programmazione EVKEY (da ordinare separatamente) è possibile eseguire l'upload e il download dei parametri di configurazione. Attraverso un'interfaccia seriale (da ordinare separatamente) è inoltre possibile collegare il controllore al sistema software di set-up Parameters Manager, a quello di monitoraggio e supervisione di impianti RICS o al dispositivo per la registrazione di dati, per il download di dati registrati (via USB) e per l'upload e il download di parametri di configurazione EVUSBREC01 (viaTTL,con protocollo di comunicazione MODBUS). Tra le molte caratteristiche si segnalano anche: grado di protezione del frontale IP65 connessione diretta dei carichi (salvo la quinta utenza) gestione di due tipi di backlight gestione su due livelli dell’allarme condensatore surriscaldato memorizzazione dell’intervallo di sbrinamento gestione adattativa dello sbrinamento (l'intervallo di sbrinamento è di volta in volta funzione delle condizioni dell'evaporatore,attraverso il continuo campionamento della sua temperatura) gestione degli allarmi di temperatura conteggio delle ore di funzionamento del compressore funzionamento per bassa o per alta percentuale di umidità relativa funzione "overcooling" (raffreddamento rapido) funzione“blocco tastiera”. EVF is a series of digital controllers for normal temperature or low temperature refrigerated showcases which design and which easiness of cleaning have an important part. The series consists of 4 instruments:EVF204,EVF214,EVF205 and EVF215. The instruments have got: real time clock (only in EVF214 and EVF215) alarm buzzer (incorporated in the user interface) 3 analog inputs (cabinet probe,evaporator probe and condenser probe) for NTC probes 2 digital inputs (door switch and multipurpose) 5 digital outputs (electromechanical relays, 4 in EVF204 and EVF214) of which one 30 res.A @ 250VAC relay for the compressor management, two 16 res.A @ 250VAC relays for defrost and load # 4 management (programmable as cabinet light, demisting heater, auxiliary output,alarm output,door heater,evaporator valve or condenser fan) and two 8 res.A @ 250VAC relays for evaporator fan and load # 5 management (this last only in EVF205, EVF215 and programmable just like load # 4);the defrost can be electric or by hot gas serial port with MODBUS communication protocol. The device is available in "split" execution (user interface + control module). The user interface looks behind a sheet of methacrylate and is made of a 4 digits custom display (with function icons) and 6 capacitive “push buttons” (set, up, down, defrost, cabinet light and on/stand-by); installation is by back-panel, with biadhesive, for its full mechanical and aesthetics integration in the showcase. The control module looks in open frame board;installation is on plain surface,with spacers. Through the real time clock it is possible to program up to 6 daily hours for the defrost activation and 1 daily hour for the “Energy Saving” function activation; function “Energy Saving” is also automatically activated,in absence of door switch input activations. Through function “HACCP” it is possible to store up to 9 events (3 in EVF204 and EVF214) for each of the 4 HACCP alarms (lower temperature alarm,upper temperature alarm,door switch input alarm and lack of power supply alarm,this last only in EVF214 and EVF215);for each HACCP alarm it is possible to store the citical value, the date and the time the alarm has arisen (these last two only in EVF214 and in EVF215) and the duration. Through the programming key EVKEY (to order separately) it is possible to make the upload and the download of the configuration parameters. Through a serial interface (to order separately) it is also possible to connect the controller to the set-up software system Parameters Manager, to the plants monitoring and supervision one RICS or to the device for the data recording, for the recorded data download (via USB) and for the upload and the download of configuration parameters EVUSBREC01 (viaTTL,with MODBUS communication protocol). Among the several features one also highlights: frontal protection degree IP65 direct loads connection (but load # 5) management of two kind of backlights overheated condenser alarm management on two levels defrost interval storing adaptative management of the defrost (the defrost interval is from time to time function of the evaporator conditions,through the continuous sampling of its temperature) temperature alarms management compressor working hours counter low or high relative humidity percentage operation function“overcooling” function“lock keyboard”. Dimensioni e installazione / Size and installation Dimensioni in mm (in) / Size in mm (in) EVF215 290.0 x 50.5 mm (11.417 x 1.988 in;L x H) • • • • Display custom da 4 digit (con icone funzione) / 4 digits custom display (with function icons) • • • • 6 tasti a sfiormaneto di tipo capacitivo / 6 capacitive "push buttons" • • • • Punto decimale grado Celsius / Decimal point Celsius degree • • • • EVF204 EVF214 EVF205 EVF215 • • • • EVF204 EVF214 EVF205 EVF215 • • • • EVF204 EVF214 EVF205 EVF215 • • • • EVF204 EVF214 EVF205 EVF215 Sonda cella / Cabinet probe NTC NTC NTC NTC Sonda evaporatore / Evaporator probe NTC NTC NTC NTC NTC NTC NTC NTC EVF204 EVF214 EVF205 EVF215 Micro porta / Door switch • • • • Multifunzione / Multipurpose • • • • Ingressi digitali (per contatto NA / NC) / Digital inputs (for NO / NC contact) EVF204 EVF214 EVF205 EVF215 Compressore / Compressor 30 A 30 A 30 A 30 A Sbrinamento / Defrost 16 A 16 A 16 A 16 A Ventilatore dell'evaporatore / Evaporator fan 8A 8A 8A 8A Uscite digitali (relè elettromecc.;A res.@ 250VAC) / Digital outputs (electromech.relays;res.A @ 250VAC) Quarta utenza / Load # 4 16 A 16 A 16 A 16 A 8A 8A Luce della cella, resistenze antiappannamento, uscita ausiliaria, uscita di allarme, resistenze della porta, valvola dell'evaporatore o ventilatore del condnsatore / Cabinet light, demisting heater, auxiliary output, alarm output, door heater, evaporator valve or condenser fan Quinta utenza / Load # 5 Luce della cella, resistenze antiappannamento, uscita ausiliaria, uscita di allarme, resistenze della porta, valvola dell'evaporatore o ventilatore del condnsatore / Cabinet light, demisting heater, auxiliary output, alarm output, door heater, evaporator valve or condenser fan Porte di comunicazione / Communication ports TTL,con protocollo di comunicazione MODBUS / TTL,with MODBUS communication protocol 91.0 (3.582) Ø 4.0 (0.157) 24.0 (0.944) 99.0 (3.897) Collegamento elettrico / Wiring diagram La massima lunghezza consentita per il cavo di collegamento interfaccia utente - modulo di controllo è di 20 m (65,614 ft) / The maximum allowed length for the connecting cable user interface - control module is 20 m (65.614 ft). EVF204 EVF214 EVF205 EVF215 • • • • EVF204 EVF214 EVF205 EVF215 • • • Per EVKEY,Parameters Manager,RICS o EVUSBREC01 / For EVKEY,Parameters Manager,RICS or EVUSBREC01 • Buzzer di allarme (incorporato nell'interfaccia utente) / Alarm buzzer (incorporated in the user interface) • • • • Connesione diretta dei carichi / Direct loads connection • • salvo la quinta utenza / but load #5 salvo la quinta utenza / but load #5 Gestione di due tipi di backlight / Management of two kind of backlights • • • • Gestione su due livelli dell'allarme condensatore surriscaldato / Overheated cond.alarm management on two levels • • • • Memorizzazione dell'intervallo di sbrinamento / Defrost interval storing • • • • Gestione adattativa dello sbrinamento / Adaptative management of the defrost • • • • Gestione degli allarmi di temperatura / Temperature alarms management • • • • Conteggio delle ore di funzionamento del compressore / Compressor working hours counter • • • • Funzionamento per bassa o per alta percentuale di umidità relativa / Low or high relative humidity percentage operation • • • • semplice / easy avanzata / advanc. semplice / easy avanzata / advanc. Funzione "Energy Saving" / Function "Energy Saving" • • • • Funzione "overcooling" (raffreddamento rapido) / Function "overcooling" • • • • Funzione "blocco tastiera" / Function "lock keyboard" • • • • Password di accesso ai parametri di configurazione / Access password to configuration parameters • • • • Ripristino delle impostazioni di fabbrica / Factory settings restoring • • • • Funzione "HACCP" / Function "HACCP" 24 27 load # 5 (prog.) 27 26 25 24 23 22 21 20 19 18 17 16 15 User interface Control module 26 25 K1 K4 serial port K3 K2 8 9 10 11 max. 20 A • 1 2 3 neutral • Orologio / Real time clock 4 line Grado di protezione del frontale IP65 / Frontal protection degree IP65 compressor Altre caratteristiche / Other features cabinet Sonda condensatore / Condenser probe evaporator Ingressi analogici / Analog inputs Modulo di controllo / Control module Su superficie piana,con distanziali / On plain surface,with spacers. power supply 14 13 12 K5 5 6 7 defrost 115...230VAC R 2.5 (0.098) 290.0 (11.417) condenser Alimentazione / Power supply 260.0 (10.236) 38.0 (1.496) door switch Faston + morsettiere fisse a vite / Faston + fix screw terminal blocks 1.5 (0.059) evaporator fan Connessioni / Connections multipurpose Scheda a giorno / Open frame board load # 4 (prog.) Modulo di controllo / Control module Interfaccia utente / User interface A retro pannello,con biadesivo / By back-panel,with biadhesive. 50.5 (1.988) EVF205 30.5 (1.200) EVF214 108.0 (4.251) EVF204 Interfaccia utente (dietro una lastra di metacrilato) / User interface (behind a sheet of methacrylate) 91.0 (3.582) Caratteristiche principali / Main features only in EVF205 and EVF215 electric system