Modelli disponibili / Available models
EVF
Controllori a 4 uscite digitali / Four digital outputs controllers
Codice / Code
Ever y Control Group
Descrizione / Description
Alimentazione 115...230VAC,buzzer di allarme,sonda cella,sonda evaporatore e sonda condensatore NTC,relè compressore da 30A
res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS
EVF204N9
Power supply 115... 230 VAC, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated 30 res.A @
250VAC,TTL serial port with MODBUS communication protocol
th
Controllori digitali per vetrine frigorifere,composti da interfaccia utente con
tasti a sfioramento di tipo capacitivo (integrabile nell'unità) e da modulo di
controllo
Digital controllers for refrigerated showcases, made of user interface with capacitive "push
buttons" (that can be integrated in the unit) and of control module
Alimentazione 115... 230 VAC, orologio, buzzer di allarme, sonda cella, sonda evaporatore e sonda condensatore NTC, relè
compressore da 30A res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS
EVF214N9
Power supply 115... 230VAC, real time clock, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated
30 res.A @ 250VAC,TTL serial port with MODBUS communication protocol
Controllori a 5 uscite digitali / Five digital outputs controllers
Codice / Code
Descrizione / Description
Alimentazione 115...230VAC,buzzer di allarme,sonda cella,sonda evaporatore e sonda condensatore NTC,relè compressore da 30A
res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS
EVF205N9
Power supply 115... 230 VAC, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated 30 res.A @
250VAC,TTL serial port with MODBUS communication protocol
Alimentazione 115... 230 VAC, orologio, buzzer di allarme, sonda cella, sonda evaporatore e sonda condensatore NTC, relè
compressore da 30A res.@ 250VAC,porta serialeTTL con protocollo di comunicazione MODBUS
EVF215N9
Power supply 115... 230VAC, real time clock, alarm buzzer, cabinet probe, evaporator probe and condenser probe NTC, compressor relay rated
30 res.A @ 250VAC,TTL serial port with MODBUS communication protocol
Per altri modelli,contattare la rete vendita Evco all’indirizzo [email protected] / For further models,please contact the Evco sales network at the address [email protected].
Accessori / Accessories
Codice / Code
Descrizione / Description
Chiave di programmazione
EVKEY
Programming key
Interfaccia serialeTTL / RS-485 non isolata
EVIF20TSX
Not insulatedTTL / RS-485 serial interface
Dispositivo per la registrazione di dati, per il download di dati registrati (via USB) e per l'upload /
download di parametri di configurazione
EVUSBREC01
Device for the data recording, for the data download (via USB) and for the upload / download of
configuration parameters
Organizzazione con Sistema
di Gestione certificato /
Company with Management
System certified
Evco si riserva il diritto di apportare qualsiasi modifica senza preavviso e in qualsiasi momento senza pregiudicare le caratteristiche
essenziali di funzionalità e sicurezza / Evco reserves the right to make any change without prior notice and at any time without prejudice the
basic safety and operating features.
EVCO S.p.A. Via Mezzaterra 6, 32036 Sedico Belluno ITALY • Phone +39 0437 852468 • Fax +39 0437 83648 • [email protected] • www.evco.it
ISO 9001:2000
118EVF2A00
EVF è una serie di controllori digitali studiati per la gestione di vetrine refrigerate a temperatura
normale o a bassa temperatura il cui design e la cui facilità di pulizia ricoprono un ruolo
importante.
La serie è composta da 4 strumenti:EVF204,EVF214,EVF205 ed EVF215.
Gli strumenti dispongono di:
orologio (solo nell'EVF214 e nell'EVF215)
buzzer di allarme (incorporato nell'interfaccia utente)
3 ingressi analogici (sonda cella,sonda evaporatore e sonda condensatore) per sonde NTC
2 ingressi digitali (micro porta e multifunzione)
5 uscite digitali (relè elettromeccanici, 4 nell'EVF204 e nell'EVF214) di cui 1 da
30 A res. @ 250 VAC per la gestione del compressore, 2 da 16 A res. @ 250 VAC per la
gestione dello sbrinamento e di una quarta utenza (impostabile per luce della cella,
resistenze antiappannamento, uscita ausiliaria, uscita di allarme, resistenze della porta,
valvola dell'evaporatore o ventilatore del condensatore) e 2 da 8 A res. @ 250VAC per la
gestione del ventilatore dell'evaporatore e di una quinta utenza (quest'ultima solo
nell'EVF205, nell'EVF215 e impostabile allo stesso modo della quarta); lo sbrinamento può
essere di tipo elettrico o a gas caldo
porta seriale con protocollo di comunicazione MODBUS.
Il dispositivo è disponibile in esecuzione "splittata" (interfaccia utente + modulo di controllo).
L'interfaccia utente si presenta dietro una lastra di metacrilato ed è composta da un display
custom da 4 digit (con icone funzione) e da 6 tasti a sfioramento di tipo capacitivo (set,up,down,
sbrinamento, luce cella e on/stand-by); l'installazione è prevista a retro pannello, con biadesivo,
per la sua completa integrazione meccanica ed estetica nella vetrina.
Il modulo di controllo si presenta in scheda a giorno;l'installazione è prevista su superficie piana,
con distanziali.
Attraverso l'orologio è possibile programmare fino a 6 orari giornalieri di attivazione dello
sbrinamento e 1 orario giornaliero di attivazione di attivazione della funzione “Energy Saving”;
la funzione “Energy Saving” viene attivata anche automaticamente, in assenza di attivazioni
dell’ingresso micro porta.
Attraverso la funzione "HACCP" è possibile memorizzare fino a 9 eventi (3 nell'EVF204 e
nell'EVF205) per ognuno dei 4 allarmi HACCP (allarme di temperatura di minima, allarme di
temperatura di massima, allarme ingresso micro porta e allarme interruzione
dell’alimentazione, quest'ultimo solo nell'EVF214 e nell'EVF215); per ogni allarme HACCP è
possibile memorizzare il valore critico, la data e l’ora in cui l’allarme si è manifestato (queste
ultime due solo nell'EVF214 e nell'EVF215) e la durata.
Attraverso la chiave di programmazione EVKEY (da ordinare separatamente) è possibile
eseguire l'upload e il download dei parametri di configurazione.
Attraverso un'interfaccia seriale (da ordinare separatamente) è inoltre possibile collegare il
controllore al sistema software di set-up Parameters Manager, a quello di monitoraggio e
supervisione di impianti RICS o al dispositivo per la registrazione di dati, per il download di dati
registrati (via USB) e per l'upload e il download di parametri di configurazione EVUSBREC01
(viaTTL,con protocollo di comunicazione MODBUS).
Tra le molte caratteristiche si segnalano anche:
grado di protezione del frontale IP65
connessione diretta dei carichi (salvo la quinta utenza)
gestione di due tipi di backlight
gestione su due livelli dell’allarme condensatore surriscaldato
memorizzazione dell’intervallo di sbrinamento
gestione adattativa dello sbrinamento (l'intervallo di sbrinamento è di volta in volta
funzione delle condizioni dell'evaporatore,attraverso il continuo campionamento della sua
temperatura)
gestione degli allarmi di temperatura
conteggio delle ore di funzionamento del compressore
funzionamento per bassa o per alta percentuale di umidità relativa
funzione "overcooling" (raffreddamento rapido)
funzione“blocco tastiera”.
EVF is a series of digital controllers for normal temperature or low temperature refrigerated showcases
which design and which easiness of cleaning have an important part.
The series consists of 4 instruments:EVF204,EVF214,EVF205 and EVF215.
The instruments have got:
real time clock (only in EVF214 and EVF215)
alarm buzzer (incorporated in the user interface)
3 analog inputs (cabinet probe,evaporator probe and condenser probe) for NTC probes
2 digital inputs (door switch and multipurpose)
5 digital outputs (electromechanical relays, 4 in EVF204 and EVF214) of which one
30 res.A @ 250VAC relay for the compressor management, two 16 res.A @ 250VAC relays for
defrost and load # 4 management (programmable as cabinet light, demisting heater, auxiliary
output,alarm output,door heater,evaporator valve or condenser fan) and two 8 res.A @ 250VAC
relays for evaporator fan and load # 5 management (this last only in EVF205, EVF215 and
programmable just like load # 4);the defrost can be electric or by hot gas
serial port with MODBUS communication protocol.
The device is available in "split" execution (user interface + control module).
The user interface looks behind a sheet of methacrylate and is made of a 4 digits custom display (with
function icons) and 6 capacitive “push buttons” (set, up, down, defrost, cabinet light and on/stand-by);
installation is by back-panel, with biadhesive, for its full mechanical and aesthetics integration in the
showcase.
The control module looks in open frame board;installation is on plain surface,with spacers.
Through the real time clock it is possible to program up to 6 daily hours for the defrost activation and
1 daily hour for the “Energy Saving” function activation; function “Energy Saving” is also automatically
activated,in absence of door switch input activations.
Through function “HACCP” it is possible to store up to 9 events (3 in EVF204 and EVF214) for each of
the 4 HACCP alarms (lower temperature alarm,upper temperature alarm,door switch input alarm and
lack of power supply alarm,this last only in EVF214 and EVF215);for each HACCP alarm it is possible to
store the citical value, the date and the time the alarm has arisen (these last two only in EVF214 and in
EVF215) and the duration.
Through the programming key EVKEY (to order separately) it is possible to make the upload and the
download of the configuration parameters.
Through a serial interface (to order separately) it is also possible to connect the controller to the set-up
software system Parameters Manager, to the plants monitoring and supervision one RICS or to the
device for the data recording, for the recorded data download (via USB) and for the upload and the
download of configuration parameters EVUSBREC01 (viaTTL,with MODBUS communication protocol).
Among the several features one also highlights:
frontal protection degree IP65
direct loads connection (but load # 5)
management of two kind of backlights
overheated condenser alarm management on two levels
defrost interval storing
adaptative management of the defrost (the defrost interval is from time to time function of the
evaporator conditions,through the continuous sampling of its temperature)
temperature alarms management
compressor working hours counter
low or high relative humidity percentage operation
function“overcooling”
function“lock keyboard”.
Dimensioni e installazione / Size and installation Dimensioni in mm (in) / Size in mm (in)
EVF215
290.0 x 50.5 mm (11.417 x 1.988 in;L x H)
•
•
•
•
Display custom da 4 digit (con icone funzione) / 4 digits custom display (with function icons)
•
•
•
•
6 tasti a sfiormaneto di tipo capacitivo / 6 capacitive "push buttons"
•
•
•
•
Punto decimale grado Celsius / Decimal point Celsius degree
•
•
•
•
EVF204
EVF214
EVF205
EVF215
•
•
•
•
EVF204
EVF214
EVF205
EVF215
•
•
•
•
EVF204
EVF214
EVF205
EVF215
•
•
•
•
EVF204
EVF214
EVF205
EVF215
Sonda cella / Cabinet probe
NTC
NTC
NTC
NTC
Sonda evaporatore / Evaporator probe
NTC
NTC
NTC
NTC
NTC
NTC
NTC
NTC
EVF204
EVF214
EVF205
EVF215
Micro porta / Door switch
•
•
•
•
Multifunzione / Multipurpose
•
•
•
•
Ingressi digitali (per contatto NA / NC) / Digital inputs (for NO / NC contact)
EVF204
EVF214
EVF205
EVF215
Compressore / Compressor
30 A
30 A
30 A
30 A
Sbrinamento / Defrost
16 A
16 A
16 A
16 A
Ventilatore dell'evaporatore / Evaporator fan
8A
8A
8A
8A
Uscite digitali (relè elettromecc.;A res.@ 250VAC) / Digital outputs (electromech.relays;res.A @ 250VAC)
Quarta utenza / Load # 4
16 A
16 A
16 A
16 A
8A
8A
Luce della cella, resistenze antiappannamento, uscita ausiliaria, uscita di allarme, resistenze della porta, valvola
dell'evaporatore o ventilatore del condnsatore / Cabinet light, demisting heater, auxiliary output, alarm output, door heater,
evaporator valve or condenser fan
Quinta utenza / Load # 5
Luce della cella, resistenze antiappannamento, uscita ausiliaria, uscita di allarme, resistenze della porta, valvola
dell'evaporatore o ventilatore del condnsatore / Cabinet light, demisting heater, auxiliary output, alarm output, door heater,
evaporator valve or condenser fan
Porte di comunicazione / Communication ports
TTL,con protocollo di comunicazione MODBUS / TTL,with MODBUS communication protocol
91.0 (3.582)
Ø 4.0 (0.157)
24.0 (0.944)
99.0 (3.897)
Collegamento elettrico / Wiring diagram
La massima lunghezza consentita per il cavo di collegamento interfaccia utente - modulo di controllo è di 20 m (65,614 ft) / The maximum allowed length for the connecting cable
user interface - control module is 20 m (65.614 ft).
EVF204
EVF214
EVF205
EVF215
•
•
•
•
EVF204
EVF214
EVF205
EVF215
•
•
•
Per EVKEY,Parameters Manager,RICS o EVUSBREC01 / For EVKEY,Parameters Manager,RICS or EVUSBREC01
•
Buzzer di allarme (incorporato nell'interfaccia utente) / Alarm buzzer (incorporated in the user interface)
•
•
•
•
Connesione diretta dei carichi / Direct loads connection
•
•
salvo la quinta
utenza / but load
#5
salvo la quinta
utenza / but load
#5
Gestione di due tipi di backlight / Management of two kind of backlights
•
•
•
•
Gestione su due livelli dell'allarme condensatore surriscaldato / Overheated cond.alarm management on two levels
•
•
•
•
Memorizzazione dell'intervallo di sbrinamento / Defrost interval storing
•
•
•
•
Gestione adattativa dello sbrinamento / Adaptative management of the defrost
•
•
•
•
Gestione degli allarmi di temperatura / Temperature alarms management
•
•
•
•
Conteggio delle ore di funzionamento del compressore / Compressor working hours counter
•
•
•
•
Funzionamento per bassa o per alta percentuale di umidità relativa / Low or high relative humidity percentage
operation
•
•
•
•
semplice / easy
avanzata / advanc.
semplice / easy
avanzata / advanc.
Funzione "Energy Saving" / Function "Energy Saving"
•
•
•
•
Funzione "overcooling" (raffreddamento rapido) / Function "overcooling"
•
•
•
•
Funzione "blocco tastiera" / Function "lock keyboard"
•
•
•
•
Password di accesso ai parametri di configurazione / Access password to configuration parameters
•
•
•
•
Ripristino delle impostazioni di fabbrica / Factory settings restoring
•
•
•
•
Funzione "HACCP" / Function "HACCP"
24 27
load # 5 (prog.)
27 26 25 24 23 22 21 20 19 18 17 16 15
User interface
Control module
26 25
K1
K4
serial
port
K3
K2
8
9 10 11
max. 20 A
•
1
2
3
neutral
•
Orologio / Real time clock
4
line
Grado di protezione del frontale IP65 / Frontal protection degree IP65
compressor
Altre caratteristiche / Other features
cabinet
Sonda condensatore / Condenser probe
evaporator
Ingressi analogici / Analog inputs
Modulo di controllo / Control module
Su superficie piana,con distanziali / On plain surface,with spacers.
power supply
14 13 12
K5
5
6
7
defrost
115...230VAC
R 2.5 (0.098)
290.0 (11.417)
condenser
Alimentazione / Power supply
260.0 (10.236)
38.0 (1.496)
door switch
Faston + morsettiere fisse a vite / Faston + fix screw terminal blocks
1.5 (0.059)
evaporator fan
Connessioni / Connections
multipurpose
Scheda a giorno / Open frame board
load # 4 (prog.)
Modulo di controllo / Control module
Interfaccia utente / User interface
A retro pannello,con biadesivo / By back-panel,with biadhesive.
50.5 (1.988)
EVF205
30.5 (1.200)
EVF214
108.0 (4.251)
EVF204
Interfaccia utente (dietro una lastra di metacrilato) / User interface (behind a sheet of methacrylate)
91.0 (3.582)
Caratteristiche principali / Main features
only in EVF205
and EVF215
electric system
Scarica

Modelli disponibili / Available models Accessori / Accessories