eXPert Main References From 2000 to 2013 This document is exclusively property of sdi s.p.a. and may not be reproduced, altered and/or distributed without prior written permission. eXPert - Main References - Rev. 01 List of revisions 2/86 REV DATE EDITOR 01 08/04/2013 Castiglioni DESCRIPTION New Document Format – revision index reset eXPert - Main References - Rev. 01 Index 1. General information eXPert product package 4 Distributed Control System (DCS) 4 eXPert DCS Components SCADA, RTU, telecontrol and remote management systems 2. 3. 4 5 5 eXPert SCADA components 6 Main Sdi typical applications 6 Main applications chronology 8 Year 2013 9 Year 2012 10 Year 2011 11 Year 2010 12 Year 2009 13 Year 2008 14 Year 2007 16 Year 2006 17 Year 2005 19 Year 2004 20 Year 2003 21 Year 2002 22 Year 2001 24 Year 2000 26 Technical data sheets 28 3/86 eXPert - Main References - Rev. 01 1. General information This document provides a summary of the main references of Sdi in automation and control system supply. Hereafter, as a general framework, an introduction to Sdi products and their scope follows, in order to facilitate the reading of the lists of references and technical data sheets. eXPert product package eXPert is a products suite created by Sdi for the implementation of distributed control systems (DCS) and systems for the remote control (Telecontrol) and it is the reference product for all systems designed by Sdi from 2002. eXPert is the result of the continuous evolution of the PSCS products family (Plant Supervisory and Control System) whose versions WIN/PSCS 2nd, WINPSCS, PSCS2000 were commercialized by Sdi since the early nineties. Distributed Control System (DCS) eXPert DCS product, designed according to a modular architecture, is purpose-built to achieve high levels of reliability and security, without losing sight of the flexibility of the architecture and the customer needs. Both the electronic subsystems, both the control firmware, are designed to ensure a high security level. Sdi focuses greatest attention to the selection of component parts with high reliability, redundant circuitry and diagnostic checks for all those elements and/or components which are relevant for the purposes of the safety integrity. The redundancy of the modules and of the communication bus is always provided as a basic functionality of the system. A careful audit of the operator actions and a flexible and precise management of the plant alarms, carried out by the control room operator workstations, enables customers to focus daily operations on both functional and security aspects. eXPert DCS manages various type of LAN and WAN connectivity (wired and wireless) in order to link all system control nodes, all other field equipment and other interconnected systems, to higher-level systems such as remote control centers or ERP business systems, in order to convey data where they are better interpretable and usable. eXPert DCS is a completely scalable and flexible product suitable for various implementations and easy to adapt to customer needs and requirements both in terms of system architecture and in terms of I/O size. eXPert DCS can manage up to 255 nodes connected on the same network, up to 1,000,000 of physical I/O at the same time and is very easy to expand allowing customers to capitalize the investment made in case of successive system extensions. In addition to traditional I/O boards, particular attention is focused on fieldbus interfaces if digital communication is available. eXPert DCS, as well as performing control and regulation functions, can be equipped with proper add-on to cover in a fully integrated solution specific requirements in terms of security (SIL 3, according to IEC 61508 and IEC 61511), fire detection and gas leak detection (F&G) and fire extinguishing. 4/86 eXPert - Main References - Rev. 01 eXPert DCS Components The main components of the eXPert DCS system are: • Modular control nodes • Programmable controllers • I/O intelligent interfaces • Fieldbus interfaces • Communication Interfaces • Programmable regulators • ESD modules (SIL 3) • F&G-Extinguishing modules • SOE recorders • Flexibles workstations (HMI) and video-wall • Engineering workstations • Storage stations • Asset Management • Advanced control and optimization modules SCADA, RTU, telecontrol and remote management systems Sdi proposes its own highly integrated SCADA platform (eXPert SCADA) composed both by the central system software (Development Tools and Runtime Applications) and by field devices (RTU/PLC) installed at the focal points of unattended subsystems. For this purpose the system as a whole has been designed to comply with safety features "Functional Safety" described in IEC 61508 and IEC 61511; software system has been developed and is being maintained in accordance with the "V-model". Both RTU/PLC and central system, have been designed and evolved over time to meet the most stringent requirements of the market in order to allow Sdi to continue proposing its own platform in monitoring and control systems for critical infrastructure. Each single element of the eXPert SCADA platform can be proposed in a redundant configuration, allowing design of architectures with hot-backup functionalities. The database system can handle up to 1,000,000 tags and can manage multi-level hierarchical structures in an integrated way in order to quickly support the creation of geographically distributed remote control systems. The human machine interface (eXPert HMI) provided by the system, is highly flexible and can run at the same time on single local stations (single or multiple monitor) , on remote stations via WEB or in complex control rooms equipped with video-wall; eXPert HMI configuration can be easily managed by the provided development tools both for systems of small/medium size and for larger systems dedicated to critical distribution infrastructure, managing thousands of animated objects on the displayed synoptics. eXPert system allows to operate with field devices through different types of communication network (telephone, LAN, WAN, wired and wireless), in single or redundant configuration. The diagnosis of connectivity and the potential automatic activation of backup connections allow the simultaneous use of different types of connection in order to optimize use and costs of different devices and networks. 5/86 eXPert - Main References - Rev. 01 eXPert SCADA platform is concept and design to guarantee anahih level of scalability and integrability allowing the system to easy interface third party RTU/PLC; similalrly, RTU/PLC devices manufactured and supplied by Sdi (using standard communication protocols of the family IEC IEC 870.5.101 and 870.5.104) can be easy integrated in preexisting systems not necessarily supplied by Sdi. In case of particularly crital controlled processes (e.g. CNI), Sdi provides natively within the eXPert SCADA solution, security functions based on DR (Disaster Recovery) structures, which allow, in case of need, the immediate switch of all control functions, to a secondary control center, completely equal (or in reduced configuration) to the main one. eXPert SCADA components The main eXPert SCADA components are: • Single or redundant SCADA server • Flexibles workstations (HMI) and video-wall • Engineering workstations • Storage stations • Communication modules to fields peripherals • Communication modules to extern systems • Wired e wireless communication management modules • Disaster Recovery architectures management • Telecontrol modular or single-board peripherals (RTU) • SCADA “Safety” (according to “V-model” standard IEC 61508 e IEC 61511) • Telecontrol “Safety” RTU peripherals • I/O intelligent interfaces • Fieldbus interfaces • SOE recorders • Asset Management • Optimization modules Main Sdi typical applications Sdi, thanks to its R & D laboratories and to the system commissioning department, using its own hardware and software platforms to implement integrated DCS-ESD-F & G and SCADA/RTU systems, has always reach the goal of a complete customer satisfaction both during supply of complete turnkey systems and during supply of single products or custom solutions to partners VAR (Value Added Reseller). The experience of Sdi has contributed, through the provision of DCS and SCADA/RTU systems steadily aligned with the technological requirements of the market, to ensure that leading Italian companies such as ENEL and ENI Group could have and operate with outstanding technological solutions. Starting from first systems developped, in compliance with very strict requirements of reliability and availability, Sdi formed a solid base of experience and project and continued over time to evolve its products and its solutions. Traditional applications are aimed to control and automation in the energy industry, in particular power production plants (from traditional sources or renewable sources) , power distribution grids and networks, high and very high voltage substations, and also in 6/86 eXPert - Main References - Rev. 01 Oil & Gas industry, in particular off-shore extraction facilities and on-shore processing, transportation and storage facilities. The changing needs of the modern market have led always more Multi Utility Companies to look with particular interest at technical solutions proposed by Sdi in order to better manage and exploit their assets. For these specific customers Sdi provides command and control systems (either local or remote) to manage power distribution grids and MV / LV substations, natural gas distribution networks, integrated water cycle and rail transport systems. In addition to control systems and remote control, Sdi has gained great experience in the Oil & Gas technical and fiscal "metering" solutions, for which applications provides measurement systems, complete skids and EMS systems. The main applications made by sdi cover the following system functions: • Supervision • Control • Commands • Regulation • Remote Sensing • Alarms • DMS Distribution Management System • Automation, control and remote control (telecontrl) of electric subsations elettriche HV/MV • MRE power grids monitoring • MOD Model On Demand: interactive real time simulation models, even integrated into the eXPert architecture, aimed to plant design, maintenance, training, and performance monitoring • SOE sequence of events recorders • Protection (SEP) ans block (SEB) elaboration. • Micro-seismic events monitoring • Loads programming • Production reporting • Leak detection • Metering systems (fiscal and technical) Hereafter are chronologically listed great part of the applications developed by Sdi during last years and the most significant, identified by the symbol , are illustrated and detailed by a summary sheet describing the system and the implemented features. 7/86 eXPert - Main References - Rev. 01 2. Main applications chronology Hereafter are chronologically listed the most significant applications developped by Sdi using its own eXPert system. Application list is ordered by year of implementation. 8/86 eXPert - Main References - Rev. 01 Year 2013 CUSTOMER SELTA ENI E&P SNAM RETE GAS APPLICATION PLANT ASAT2SAS systems for HV substation automation revamping. TERNA HV substations of Foggia and Codrongianos Integrated GAS measures acquisition system (SIAM): supply, installation and activation; on call maintenance service Italian primary gas distribution network (Snam Rete Gas) Wireless analog, digital and serial data acquisition and data concentrator GAS treatment plants of Mortara and Terranuova Bracciolini * 9/86 eXPert - Main References - Rev. 01 Year 2012 CUSTOMER PLANT Local Control System, telecontrol Gateway, Phase Shift Transformers (PST) automation Villanova Terna HV Substation, PST section HYDROS Hydro Plant DCS revamping Brunico Hydro Power Plant SNAM RETE GAS Natural gas metering system. Enna Gas compression station RTU/ESD/F&G system for ENI Adriatica Gas Well Colle Sciarra Supervision system revamping Castiglione Olona cogeneration plant Design and production of a new RTU for secondary gas network minitoring (RID special version)) SNAM secondary gas network A2A GAS telecontrol system integration Canavese and Macconago GAS distribution network SNAM RETE GAS Fiscal metering of natural GAS lines Enna Gas compression station DCS revamping APRICA Waste to Energy Plant SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS 2012 system) Terna HV Substation Molini di Tures SELTA ASAT2SAS system: revamping of HV substation automation system TERNA HV Substations Marginone and Ravenna Canala Grosio PCTC system revamping Valtellina Hydro power Plants ALMAVIVA Data acquisition station (UAS) revamping with a new CPU board (NTA ) for 210 systems Trenitalia Railways: Lombardia and Piemonte YANMAR Research project for an Energy management System (EMS) of a tri-generation plant (CHP) Aequalis Pontedera (PI) SELTA COSMI MAZZUCCHELLI 1849 SNAM RETE GAS FRANCO TOSI A2A 10/86 APPLICATION * 35 54 eXPert - Main References - Rev. 01 Year 2011 CUSTOMER APPLICATION PLANT * ENEL GREEN POWER Telecontrol Center (PT) and remote supervision Romania Country Control Room (CCR) (PTS) of photovoltaic and wind power plants Romania - Bucarest 29 ENEL GREEN POWER Telecontrol Gateway for power production in photovoltaic and wind power plants 20 plants in Italy and Romania 30 ENI E&P Telecontrol of Guendalina off-shore platform Off-shore platform Guendalina Technical GAS metering lines Bordolano Gas compression station Supply of 27 RTU for the pipeline telecontrol system Gas Pipeline TRANSITGAS (Svizzera) Supply of UPT boards A2A Milan Electric network (MV/LV) Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) Terna HV/MV Substations of CAMPOROSSO (IM), MEDUNO (PN), AGORDO (BL) 10 Telecontrol systems for photovoltaic production plants Plants remote controlled by TERNA in northern Italy SNAM RETE GAS TRANSITGAS BOFFETTI SELTA GAVAZZI SNAM Supplyof single loop controlle devicesr SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS 2012 system) Terna HV/MV Substations PIOSSASCO (TO) and VILLACASTELLI (BR) A2A Telecontrol MV/LV network: supply of RTU pripherals MV/LV Network Milano SELTA DMS system for Electric network MV/LV (managed by SELNET) MV/LV Network Alto Adige ASTEA DMS system for MV/LV electric network MV/LV Network Osimo – Recanati SELTA ASAT2SAS system prototipe for the revamping of HV HV Substations TERNA substation automation SUDELETTRA ENEL PRODUZIONE SELTA Gas compression station metering system ENI gas compression station of Candela Supervision system(SDS) revamping forpower generation units TI42 e TI53 Thermoelectric Plant Ettore Majorana (Termini Imerese) Local Control System, Telecontrol Gateway, Phase Shift Transformers (PST) automation Foggia Terna HV Substation 31 35 35 32 35 11/86 eXPert - Main References - Rev. 01 Year 2010 CUSTOMER PLANT EDISON Hydro Power Plant DCS revamping Hydro Power Plant of Sonico (BS) EDISON Alarm system/RCE Marghera Azotati (VE) HV/MV Substation Control System Steelworks Lucchini (BS) ACEA Optimized Regulation system (OxyFuzzy regulation) for waste water treatment Waste Water Tratment Plants Ostia (ACEA Roma) SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) Substation TERNA HV/MV di GLORENZA(BZ), CARDANO(BZ) e ITTIRI(SS). SELTA Local control system (Station Computer), telecontrol gateway, small HV/MV substation automation system (SAS-s compact system) Prototype for qualification by Terna SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) TERNA HV/MV Substations:i FADALTO(TV) and VALMONTONE(ROMA) PROGETTO SMART GRIDS NAVICELLI Networks innovative management based on thermal and electrical energy storage technologies Experimental system at NAVICELLI S.p.A. (PI) Gas Pipeline Telecontrol Center upgrade and SW customizations TRANSITGAS Gas Pipeline (CH) HP Editing of test plans for the commissioning of the Telecontrol Center of the Italian gas primary network SNAM Rete Gas dispatching center HP Frontend system development for data acquisition from RTU 3G, RTU 2G used in primary gas network Italia. SNAM Rete GAS dispatching center Customizations for prototype validation system of station computer for HV Terna stations with single busbar circuit configuration Prototype for qualification byTERNA Redundant RTU for interfacing with the network telecontrol system of TERNA INNSE MT Substation APRICA Waste to energy plant DCS revamping Bergamo waste to energy plant SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) TERNA HV/MV Substations of SAN BELLINO (RO) and VILLANOVA(PC) BOFFETTI Supply of UPT boards Electric network MV/LV A2A Milano HYDROS Supply of Alarms, Measures ans SOE lists system Hydro Power Plant Ponte Gardena NENKI STEEL (GRUPPO VIENNA) Redundant RTU for TERNA network management MT Electric Substation LUCCHINI TRANSITGAS SELTA INNSE CILINDRI (GRUPPO RIVA) 12/86 APPLICATION * 77 35 35 31 35 eXPert - Main References - Rev. 01 Year 2009 CUSTOMER SNAM Rete GAS Edison APPLICATION Gas compression station DCS (primary gas distribution network) PLANT Gallese Gas Compression Station (VT) Telecontrol of Off-shore Platform Annamaria B Off-shore platform Annamaria B HYDROS Hydro Power Plant DCS Revamping Brunico Hydro Power Plant Edison 33 Feasibility study for gas storage telecontrol system ENI E&P Enel Green Power * Standardized Telecontrol Gateway prototipe for wind farms SOE system Hydro Power Plant Caffaro 2° A2A Hydro Power Plant Telecontrol A2A Hydro Power Plants in Calabria A2A MV/LV Telecontrol network :RTU peripherals supply MV/LV Network Milano ENEL Thermo electric power generation units supervision system upgrade Units 3-4 Torre del Sale Power PlantPiombino ENEL Thermo electric power generation units automation and control system Capraia Isola Power Plant Gas Pipeline line-pack function Gas Pipeline Libya Control System and Supervision (SCS Gallese) Gas compression station Gallese TSF Railway station SCADA and data acquisition devices for railway traffic control Rail Network RFI (Italy) SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) TERNA HV/MV Substations of CIMEGO (TN) and BUSSOLENGO (VR) 35 SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) TERNA HV/MV Substations of POPULONIA (LI) and COLLARMELE (AQ) 35 SELTA Redundant SCADA for TERNA MRE systems (electric transport network monitoring) TERNA HV Substations ENI GREEN STREAM SNAM RETE GAS SOMECO ACEA 34 34 Additional DCS node and Telecontrol and Supervision ENI Station CROTONE system extension Dualisation of public lighting telecontrol system Public lighting telecontrol system of Rome 13/86 eXPert - Main References - Rev. 01 Year 2008 CUSTOMER PLANT Supervision and control system of turbogas power FIAT plants FIAT plants of Acerra 22 skid for gas fiscal ultrasonic metering, and related centralized management system 7 gas compression and treatment plants Potable and waste water network telecontrol system (Telecontrol centre and RTU Perioherals) Potable and waste water network Verona and neighboring municipalities Gas quality data update monthly service Snam Compression stations SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) Gerbido TERNA HV/MV substation (GE) EDISON Hydro Power Plant DCS Cividate Hydro Power Plant Supply of RTU (RID e PIDA) for secondary gas network monitoring Secondary gas network of SNAM Wind farm supervision SCADA Wind Farm La Miniera (Montecatini val di Cecina) Central telecontrol room and telecontrol system extension for Rome public lighting (Telecontrol Center and RTU peripherals) Rome public lighting Hydro Power Plant SOE lists and alarms Premesa Hydro Power Plant Telecontrol network MV/LV: Supply of RTUs (140 devices) Network MV/LV Milano Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) TERNA HV/MV Substations: Uvini (CA) and Rubiera (RE) Revamping of gas distribution telecontrol system Milan gas distribution network Renewal of supervision and control systems of combined cycle cogeneration power plants Sulmona and Melfi power plants Railway station SCADA and data acquisition devices for railway traffic control Rail Network RFI Renewal of Hydro Power Plant DCS Hydro Power Plant Prati di Vizze Extension of fiscal metering system Malborghetto station (UD) Malborghetto (UD) SNAM gas compression station Telecontrol Center SCADA system and SW customizations Gas Pipeline TRANSITGAS (CH) 70 RTU IIIG for primary gas network telecontrol Primary gas network SNAM COFATHEC STOGIT SELTA – Acque Veronesi SNAM RETE GAS SNAM RETE GAS GAVAZZI IMPIANTI ACEA Electrabel EDISON AEM SELTA AEM BG Italia Power TSF EDISON SNAM RETE GAS SELTA SNAM RETE GAS 14/86 APPLICATION * 38 40 36 39 eXPert - Main References - Rev. 01 CUSTOMER APPLICATION SIBA Supply of DCS system with OxyFuzzy optimized regulation for the Carini (PA) wastewater purification plant Carini (PA) wastewater purification plant Public lighting telecontrol system maintenance agreement Rome public lighting 4 power units (320 MW each) supervision system maintenance agreement Piombino ENEL power plant ACEA Electrabel ENEL PLANT * 37 15/86 eXPert - Main References - Rev. 01 Year 2007 CUSTOMER PLANT SNAM RETE GAS RTU (RID e PIDA)supply agreement for the secondary gas distribution network Italy Secondary gas network SNAM ACEA Electrabel Public lighting telecontrol system (Telecontrol Center and RTU Peripherals) Rome public lighting Supply of RTU peripherals (140 devices) for the MV/LV telecontrol network MV/LV network Milano AGS Peschiera del Garda Potable water distribution and waste water SCADA based Telecontrol system (center and peripherals) Aqueducts Garda, Peschiera and neighboring municipalities. Waste water collector Garda Est SELTA Local control system (Station Computer), telecontrol gateway, HV/MV substation automation system (SAS system) TERNA HV/MV substation Lago Boracifero (Larderello) RTU for the off-shore platform Benedetta Off-shore platform Benedetta N.3 supervision and control systems turbogas power plants (mono e bi-gruppo) stabilimenti FIAT Stabilimenti FIAT di Rivalta, Cassino, Termoli. AEM ENI British Gas Power Italy EMERSON Fiscal metering systems per centrali SNAM CPL Concordia Fiscal metering system Minerbio gas station Edison Minerbio gas station SNAM RETE GAS Supply of 69 RTU for gas network telecontro Network nazionale gasdotti SNAM SELTA SNAM RETE GAS Station Computer, Telecontrol Gateway, HV/MV TERNA HV/MV Pallanzeno substation automation (SICAS STANDARD system) substation Supply of a new hystorical data archiving system for supervision and telecontrol systems (STS) SELTA Station Computer, Telecontrol Gateway, HV/MV TERNA HV/MV Leini substation’ substation automation (SICAS STANDARD system) COGEME SELTA * 56 43 45 58 Supply of 13 single loop controller devices STOGIT EDIPOWER 16/86 APPLICATION Alarms acquision and visualization system, hardware and software revamping of the supervision system Operational centres CREMA and SERGNANO San Filippo del Mela Unit:1-2 of the power plant SCADA upgrade for waste water collection plant telecontrol Redundant SCADA and GATEWAY (MRE) for HV/MV substations remote monitoring TERNA HV/MV substations 44 eXPert - Main References - Rev. 01 Year 2006 CUSTOMER APPLICATION PLANT EDISON Gas Pipeline telecontrol system Cavarzene – Minerbio gas pipeline STOGIT HW/SW maintenance agreement and h24/365 support for SIRIONE Telecontrol system Crema Operating Center ENI FIMIGAS Supply of 50 VESCOM fiscal metering devices Candela gas treatment plant SNAM RETE GAS 52 RTU for the Italian primary gas network telecontrol Italian national gas network SNAM Enel Ricerca Pisa SW development for the thermo electric power plant simulator Sulcis Thermo electric power plant Wastewater purification plant DCS and central telecontrol room Wastewater purification plant of Terrarossa, Orbetello lagoon Ecoveneta SELTA 42 HW maintenance agreement and h24/365 support for UGIT (Italia) Telecontrol system Supply of n. 3 RTU andTelecontrol Center for gas treatment station SUDELETTRA * Remote operation telecontrol center (PT) with EMS Telecontrol centers of TERNI and functions for ENDESA power production plants in Italy POMEZIA 55 50 46 Gas Pipeline telecontrol system Tunisian section of the TRANSMED Gas Pipeline 48 Snamprogetti 3 DCS for the gas compression stations of Sbikha, Sbeitla and Korba - Gas Pipeline TRANSMED (Tunisia) Sbikha,Sbeitla e Korba gas compression stations 49 EMERSON/Snam Rete Gas 5 management systems of 18 ultrasonic gas fiscal metering skids 5 Compression stationsSnam 20 ultrasonic gas fiscal metering skids, and its management system 5 Compression stationsSnam SW for gas compression management Roseto station Roseto gas station ENI SCOGAT Snam Rete Gas SO.ME.CO (per ENI E&P) ENI Gas treatment control and off-shore platform telecontrol at Casalborsetti, SW maintenance agreement and h24/365 support for Ravenna Mare, Rubicone, Fano, control system supplied by Sdi (duration: 3-5 years). Falconara, Spilamberto, Crotone, Roseto and Pisticci gas stations TSF Supervision and Control System railway traffic (CCL/SCT); Supply of di data acquisition devices UAS, nano UAS, railway station SCADA, redundant SCADA and HMI for central control rooms RFI Railways (Italian Railways) Public lighting telecontrol system (pilot system) Rome public lighting SCADA systems upgrade Casalborsetti, Ravenna Mare, Fano, Rubicone gas station and telecontrol centers ACEA Electrabel ENI/UGIT 47 47 17/86 eXPert - Main References - Rev. 01 CUSTOMER STOGIT ACSM COMO 18/86 APPLICATION PLANT Gas storage Supervision and Telecontrol (STS) Crema Operating Center Water/Gas distribution network telecontrol system Como potable water and gas distribution networks * 52 51 eXPert - Main References - Rev. 01 Year 2005 CUSTOMER APPLICATION PLANT Gas Pipeline leak detection and telecontrol system IGTS – Iranian Gas Transmission System MRE system (Electric network monitoring) – 36 SCADA/engineering systems TERNA HV/MV substations 75 RTU for the telecontrol of the Italian national gas primary network National primary gas network SNAM TSF Supervision and Control System railway traffic (CCL/SCT); Supply of 172 data acquisition devices UAS, 34 nano UAS, 211railway station SCADA, 12 redundant SCADA and HMI for central control rooms. Linee ferroviarie RFI AEM MV/LV network telecontrol Network MV/LV Milano Extension of the existing control system (DCS) supplied by Sdi (third lot) Purification and treatment of wastewater from tanneries of the consortium EMERSON PROCESS SELTA SNAM RETE GAS CONSORZIO CONCIATORI FUCECCHIO (FI) GASPLUS ENEL SNAM RETE GAS AEM EDISON Training simulator for circulating fluidized bed plant Sulcis power plant Supply of 183 RTU secondary gas network monitoring (RID e PIDA) SNAM gas distribution network Grosio Telecontrol system (supplied by Sdi) – upgrade of the system and load management system Telecontrol Center for hydro plants of Valtellina Alarm system Hydro Power Plant Lasa (BZ) Prototipe of RTU for telecontrol of the primary gas national network ENI/UGIT Telecontrol systems (supplied by Sdi) upgrade and adaptation of ront end (FEP) for the installation of new radio connections 45 off-shore platforms and 5 on-shore stations (Ravenna Mare, Casalborsetti, Fano, Rubiconde, Falconara) Alarms, Measures and SOE systems. Hydro power plants of Battiggio and Esterle DCS for Building Automation ICT center rooms and air conditioning plants AGOS ITAFINCO ENI/UGIT STOGIT GREENSTREAM (ENI) 53 55 75 56 Remaking of telemetering system and gas production data management SNAM RETE GAS EDISON * 60 54 63 Framework contract covering SW maintenance for all telecontrols system supplied by Sdi Framework contract covering SW maintenance for the telecontrol system supplied by Sdi Crema operating center Telecontrol Gas Pipeline and maintenance agreement Lybian Gas Transmission System 19/86 eXPert - Main References - Rev. 01 Year 2004 CUSTOMER PLANT * SELTA DMS system, Telecontrol of the distribution electric network, network simulator AGSM Verona MV/LV network and substations 61 SELTA Station Computer, Telecontrol Gateway, HV/MV substation automation (SICAS STANDARD system) Prototipe system,for certification by TERNA, of a digital automation system for HV/MV substations 58 SELTA DMS and electric network telecontrol system ASM BRESCIA MV/LV electric network and substations 64 SELTA MRE system (electric networks monitoring) TERNA HV/MV substations; prototipe for TERNA certification. 59 TSF Supervision and Control System of railway traffic (CCL/SCT); supply of 84 data acquisition devices UAS, 84 railway station SCADA, 4 redundant SCADA and HMI for central control rooms Railway lines: Milano-Domodossola, Rho-Novara-Porto Ceresio, Milano– Brescia, Milano–Tortona, MilanoChiasso TSF Supervision and Control System of railway traffic (CCL/SCT); supply of 56 data acquisition devices UAS, 56 railway station SCADA, 3 redundant SCADA and HMI for central control rooms Railway lines: Torino-Modane, Nodo Torino, Torino-Trecate, TorinoAlessandria 75 TSF Supervision and Control System of railway traffic (CCL/SCT); supply of 64 data acquisition devices UAS, 64 railway station SCADA, 2 redundant SCADA and HMI for central control rooms Railway lines: Firenze Nodo, Linee Sicilia 75 TSF Supervision and Control System of railway traffic (CCL/SCT); supply of 72 data acquisition devices UAS, 72 railway station SCADA, 3 redundant SCADA and HMI for central control rooms Railway lines: Udine-Monfalcone, Udine-Cervignano, Mestre, TriesteVenezia 75 ENEL Loads and production programming system Boazzo hydro power plant AVIO Upgrade of the turbogas control system supplied by Sdi Larino (ENEL) turbogas power plant SNAM RETE GAS Supply of RTU gas network monitoring (RID e PIDA) SNAM gas network MAZZUCCHELLI Cogeneration power plant – upgrade of the system supplied by Sdi Castiglione Olona cogeneration power plant Paper mill automation – upgrade of the system supplied by Sdi Duino (Trieste) paper mill Production programming system Thermo electric power plant S.Filippo del Mela EDISON Load controller and level regulation Sonico Hydro Power Plant STOGIT Telecontrol of gas storage plants from the SIRIONE center Brugherio gas storage plant EDISON Alarm, Measure and SOE systems Battiggio and Esterle hydro power plants CARTIERE BURGO EDIPOWER 20/86 APPLICATION 75 69 63 eXPert - Main References - Rev. 01 Year 2003 CUSTOMER GREENSTREAM (ENI) ENI/UGIT STOGIT APPLICATION Sistema SCADA e LEAK DETECTION PLANT Lybian Gas Transmission System Ripalta gas storage plant RTU for platform telecontrol from Ravenna Mare telecontrol center Off shore platform TEA (ENI DIV. E&P) ENEL PRODUZIONE Distributed cogeneration plants telecontrol system Cogeneration Plants for clients ENEL PRODUZIONE ENEL PRODUZIONE RICERCA Design and development of process and regulation models for the engineering dinamic simulator of Sulcis power plant ENI/UGIT Upgrade of 9 Telecontrol systems for fiscal metering management ENEL PRODUZIONE RICERCA Development and implementation of process models and control for ingineering simulator solid waste treatment (TDS) ENEL PRODUZIONE RICERCA Trining dynamic simulator of the desulfurization plant for unit 1 of thermo electric power plant of Brindisi Sud. DESOX power plant Brindisi Sud FORES ENGINEERING RTU for platform telecontrol from Ravenna Mare telecontrol center REGINA off shore platform (ENI DIV. E&P) CESI Supervision and control of an experimental hybrid distributed generation power plant. Cesi AEM Extension of (sdi supplied) Grosio hydro plants telecontrol system (front end IEC 60870-5-101) Telecontrol Center for all hydro power plants in Valtellina (Grosio telecontrol center) FIMIGAS Supply of VESCOM devices for fiscal metering Va Tech Hydro Hydro power plant unit automation Generation unit 3 of Premadio 65 RTU gas network monitoring (RID e PIDA) Network gas SNAM ENEL PRODUZIONE Extension of supervision and control system units 3-4 Piombino power plant CARTIERA DEL MAGLIO Revamping of automation and control system (DCS) Maglio paper mill TECNOMARE RTU for the remote control of offshore platform from the gas treatment plant of Rubicone Off shore platform NAIDE (ENI DIV. E&P) SNAM RETE GAS 62 Framework contract covering SW maintenance for all telecontrols system supplied by Sdi for the customer Water re-injection plant telecontrol FORES ENGINEERING * 66 67 69 21/86 eXPert - Main References - Rev. 01 Year 2002 CUSTOMER PLANT * Remote control of offshore platform GARIBALDI K from the gas treatment plant of Casalborsetti Casalborsetti gas treatment plant Three-year maintenance contract HW/SW gas storage plants telecontrol system SIRIONE Operatind center Crema SCADA system for gas treatment plant control and connected offshore platforms telecontrol Crotone Gas treatment plant Upgrade and extensionof gas wells telecontrol system. Supply of 25 RTU Gas wells, treatment station and national control centre. EDIPOWER Power plant automation control and supervision system (3 units 20 MW each) Hydro Power Plant di Ampezzo (UD) EDIPOWER Thermoelectric power plant units 160 MW blocks elaboration system PCT S.Filippo del Mela (ME) thermo electric units 1-2 and 3-4 72 EDIPOWER Supply of DCS cabinet for analog input (STAR) PCT S.Filippo del Mela (ME) thermo electric units 1-2 and 3-4 73 ENI DIV. E&P STOGIT ENI DIV. E&P SPI CESI RTU for the remote control of offshore platform from the gas treatment plant of Rubicone Platform off-shore NAIDE (ENI DIV. E&P) SFERA Interfacing between ABB DCS and operators training simulation system SFERA (ENEL group) Piacenza COSMI Off-shore platforms automation and telecontrol system: on site maintenance Piattaforms of competence of Fano and Rubicone EPC (Engineering Procurement Construction) aimed at making the gas treatment plant remote controlled Gas treatment plant Spilamberto Denitrification plant automation Electricity generation plant from nontoxic waste in Bergamo Supervision and Control System of railway traffic (CCL/SCT); supply of data acquisition devices UAS, local station SCADA, central control rooms SCADA and HMI Railway line RIMINI ANCONA STOGIT Hystorical process data archiving system (on ORACLE database) with WEB interface(in Intranet) Crema operating center SNAM RETE GAS 114 RTU for gas network monitoring (RID e PIDA) SNAM gas network CESI RAF SIBILO: Advanced diagnostic system for boiler burners Tarragona power plant STOGIT Extension of SIRIONE system for the telecontrol of gas storage station of Fiumetreste and Brugherio Crema operating center BERGAMO AMBIENTE SERIZI TSF 70 71 Relational database (ORACLE) for the management, via WEB interface, of historical data and forecasts, for Operating center of GRTN (Rome) the Italian Electric network (loads and generation) TECNOMARE ENI DIV. E&P 22/86 APPLICATION 74 75 65 69 eXPert - Main References - Rev. 01 CUSTOMER SNAM RETE GAS APPLICATION 50 RTU per monitoraggio network gas (RID e PIDA) PLANT Network gas SNAM * 69 STOGIT Extension of SIRIONE system for the telecontrol of 8 Gas compression stations and Crema gas compression stations operating center 65 EDISON Automation and telecontrol system of N. 5 power generation units Hydro Power Plant of Sonico 77 TSF Supervision and Control System of railway traffic (CCL/SCT); supply of 13 data acquisition devices UAS, 13 railway station SCADA, 1 redundant SCADA and HMI for central control rooms Sistema CCL/SCT for the following railway lines: MILANO-CHIASSO, BOLOGNA-MILANO-PADOVA, CANCELLO-SARNO STOGIT Extension of SIRIONE system for fiscal metering of the production of the 8 gas storage stations Gas storage stations AEM Milano Sistema di automazione, regolazione, supervisione network di distribution GAS Milan gas distribution network CONSORZIO CONCIATORI FUCECCHIO (FI) Extension of the existing DCS system (provided by Sdi) Purification and treatment of wastewater from tanneries of the consortium TSF 111 railway station local SCADA for the Supervision and Control System of the railway traffic M42/SCT system for the following railway lines: ROMA-SULMONA, BRENNERO, PIEMONTE. TSF Supervision and Control System of railway traffic (CCL/SCT); supply of 10 data acquisition devices UAS, 10 railway station SCADA, 1redundant SCADA and HMI for central control rooms. CCL/SCT system for the following railway lines: BOLOGNA – RIMINI. VOITH-RIVA HYDRO Automation and telecontrol system of N. 1 unit of 105 MW Grosio Hydro Power Plant 75 76 75 23/86 eXPert - Main References - Rev. 01 Year 2001 CUSTOMER PLANT RAF SIBILO: N. 2 SCADA/HMI for boiler advanced diagnostic functionalities Thermo electric power plant Brindisi sud – Enel and Taiwan BERGAMO AMBIENTE SERVIZI Turbogas power plant automation, regulation and supervision system Bergamo waste to energy plant RETE GAS ITALIA (SNAM) RID e PIDA: new RTU prototipe for gas network monitoring Gas network italia FORES ENGINEERING RTU for platform telecontrol from Falconara plant center Off-shore platform CALIPSO – ENI DIV. E&P ENEL PRODUZIONE RICERCA Project of an HW-SW system for real time process diagnostic functions Combined cycle power plant La Spezia ENEL PRODUZIONE RICERCA µSTAR: Supply of RTU for microturbine systems Livorno experimental area ENEL PRODUZIONE RICERCA Consulting contract for configuration and test of automation and operator interface dynamic simulator Desox ENI DIV. E&P Two-year contract for software preventive scheduled maintenance and system support Gas production plants and substations in the operating district of Ravenna ENEL PRODUZIONE Automation and control systemdi hydro power plant Hydro Power Plantdi Boazzo (TN) ENEL PRODUZIONE Extension of supervision system for the acquisition of temperature data of turbo-alternator Power generation units 3 e 4 della C.le Termoelettrica di Piombino (LI) BALANCE SYSTEM Supervision system for balancing machines CESI C.I.S.R ENI DIV. E&P TSF S.p.A. AEM Milano 24/86 APPLICATION Telecontrol percolate flow Urbaine waste disposal - Vergiate New Telecontrol system offshore platforms UNIX environment Gas treatment plant of CasalBorsetti (RA) 43 licences railway SCADA system for the supervision and control of the railway traffic Railway Lombardia Single lamp control Public lighting Città di Milano * 78 79 eXPert - Main References - Rev. 01 CUSTOMER ENI DIV. E&P FIMIGAS ENI DIV. E&P APPLICATION Telecontrol Platform Cervia K PLANT Gas treatment plant Rubicone Gas treatment plant Fano N.4 supervision and control systems of n. 4 gruppi turbo-gas Thermoelectric power plant of Montalto (EUROGEN) Automation, supervision and telecontrol system. Waste water collector east Garda Lake APS: Supply of 15 devices for regulation and elaboration of gas flow and Telecontrol Telecontrol e tele-metering secondary gas network SNAM 80 licences railway SCADA system for the supervision and control of the railway traffic (CCL/SCT) Railway Milano - Bologna ENI DIV. E&P Supervision system and telecontrol of gas storage plants of Minerbio and Sabbioncello Operating district Crema DICR ENI DIV. E&P Three-year contract for maintenance of hardware, supervision and control systems Gas treatment and off-shore platforms Ravenna DIRA district AZIENDA GARDESANA SERVIZI FIMIGAS TSF S.p.A. 80 VESCOM: Supply of n. 90 fiscal volumetric and Venturi-type gas meters 3C e 3V SCADA interfacing with DCS MOORE APACS AVIO * 25/86 eXPert - Main References - Rev. 01 Year 2000 CUSTOMER TSF S.p.A. 75 licences railway SCADA system for the supervision and control of the railway traffic (CCL/SCT) PLANT Railway line Roma – Napoli Battipaglia ENEL PRODUZIONE RICERCA Development of software and models in modeling environment LEGO and SID ENEL PRODUZIONE Power plant DCS: extension of analog and digital I/O Piombino thermo electric power plant Supervision system units.1-2 FIMIGAS APS: Supply of 11 dedicated devices for regulation, flow calculations and telecontrol Telecontrol and telemetering secundary gas network SNAM ENI DIV. E&P Maintenance agreement for N. 2 supervision systems Supervision system gas storage plants – Crema district AEM MILANO Supervision systeme Telecontrol heating production plants District heating plants Milano Automation, supervision and control system Hydro Power Plant of Calore Offshore platforms telecontrol system in UNIX environment N. 32 Offshore platforms – Gas plant treatment plant of Falconara (AN) Alarm system Turbogas power plant Porto Marghera CESI Internet based training simulator for ENEL power plants ENEL power plants ENI DIV. E&P Software development for onshore-offshore telephonic network used for the teleontrol system C.le ENI DIV. E&P di produzione e gas metano di e CasalBorsetti - ENI DIV. E&P RTU for telecontrol functions (Connected to CasalBorsetti control center) Platform off-shore NAOMI PANDORA– ENI DIV. E&P Simulation software development ENEL power pants simulation Hardware and software automation and control system for the whole paper mill Paper mill Pontecchio Marconi (Cartiera del Maglio) µSTAR: 5 RTU for the remote sensing of explosive atmospheres in isolated wells ENI DIV. E&P gas production plants of Falconara and CasalBorsetti - ENI DIV. E&P HV substation automation system Brunico Hydro Power Plant Sistema di Telecontrol di offshore platforms in ambiente UNIX N. 4 Offshore platforms Clara Complex e Bonaccia - Centrale di trattamento gas di Falconara (AN) ENI DIV. E&P AVIO N.2 supervision and control systems di n. 2 gruppo turbo-gas Thermoelectric power plant di Termini Imerese (ENEL) FIMIGAS VESCOM 4 - Supply of.75 gas measuring devices SNAM gas distribution network AVIO Supervision and control systems of n. 4 turbo-gas units Thermoelectric power plant of Turbigo (EUROGEN) EUROGEN ENI DIV. E&P EDISON MARINO ROSETTI CESI CARTIERA DEL MAGLIO ENI DIV. E&P EDISON SAIPEM M. ROSETTI 26/86 APPLICATION * eXPert - Main References - Rev. 01 CUSTOMER CARTIERA DELICARTA CONSORZIO CONCIATORI FUCECCHIO (FI) APPLICATION Supervision and control system PLANT Cogeneration plant Porcari (LU) factory Purification and treatment of DCS system for supervision, controllo, telecontrol and wastewater from tanneries of the automation consortium µSTAR: 17 RTU µSTAR/SAD for micro-seismic signals recording and 1 RTU for conventional I/O While-Drilling SINGLE LOOP: N. 8 regulation systems Secundary gas distribution network ENI DIV. E&P µSTAR: 2 RTU for Telecontrol of monotubolar Platform Morena Gas treatment plant Rubicone TECNOMARE RTU oerioheral and extension of telecontrol system of Falconara Platform off-shore BARBARA T2 – ENI DIV. E&P AEM MILANO Automation and telecontrol system of N. 2 , 75 MW hydro power plant units Hydro Power Plantdi Premadio ERGA GRUPPO ENEL SNAM * Application described in technical data sheet 27/86 eXPert - Main References - Rev. 01 3. Technical data sheets Following are the brief technical specifications that describe the systems provided by Sdi summarizing the main features. They are arranged in reverse chronological order starting from the most recent. 28/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT GATEWAY ENEL GREEN POWER WIND FARM AND PV POWER PLANTS IN ITALY AND ROMANIA LOCAL MONITORING AND CONTROL SYSTEM UNIFIED GATEWAY FOR WIND AND PHOTOVOLTAIC POWER PLANTS SYSTEM ARCHITECTURE • • • • • • 1 SCADA System 1 Local HMI Gateway (integrated on the SCADA PC) toward the remote control center (PT) and the remote monitoring center (PTS). Redundant STAR OHP controller managing the following communication protocols: 61850, 60870-5-104/101, MODBUS, 62056-25, OPC. Additional rack for physical I/O boards. Number of I/O managed, dependent on plant size, from 1000 TAG (for the smallest FV fields) to over 10000 TAG for wind farms with more than 50 wind turbines (WTG). MAIN FEATURES Local control and monitoring system for large photovoltaic plants (with average powers greater than 2 MW) and medium to large wind farms with more than 30 turbines. The systeme acts as local SCADA and HMI and also as a gateway for remote (PT) and telemonitoring (PTS). The system is based on the standard of communication and configuration definition IEC 61850 and uses the communication standard IEC 60870-5-104 for remote control applications, while maintaining a high degree of flexibility in the choice of additional protocols used in the plant-specific function (devices installed by different vendors). PHISICAL I/O (FOR 25 < WTG < 36 ) Digital Input 80 Digital Output 32 Measures 8 Set Point 8 TOTAL I/O From 1000 to over 10000 TAGS, including points from field communication protocols 29/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT TELECONTROL ENEL GREEN POWER WIND FARM AND PV POWER PLANTS IN ITALY AND ROMANIA REMOTE CONTROL AND MONITORING OF WIND AND PHOTOVOLTAIC POWER PLANTS SYSTEM ARCHITECTURE • • • • • • • • • • • Sistem based on double blade server (IBM Blade Center). 1 blade reserved to PT SCADA, PT Front End and Oracle Database on each server. 1 blade reserved to PTS SCADA, PTS Front End on each server. 1 blade reserved to Engineering functions. 1 blade reserved to web server functions Triple RAID disks on each blade server 4 Workstation for operator double monitor HMI (2 for PT , 2 for PTS) 1 Workstation for Engineering tasks 1 Workstation for 4 monitor Video wall management Redundant LAN based on managed switches to confine PT and PTS functions Network components SNMP based diagnostics integrated into the SCADA system MAIN FEATURES Remote monitoring and control system for large-scale photovoltaic plants (on average with power greater than 2 MW) and for medium to large wind farms with more than 30 turbines. The system is divided into the functions of supervision (PTS) and remote (PT). For each function was adopted full hardware and software redundancy. Communication with the local plant control systems is achieved through the communication protocol IEC 60870-5104, and includes the connection is with both the local SCADA and RTU. The system includes the function of remote alarm via GSM to the staff on duty. I/O DATASET Digital Input 10000 30/86 Digital Output 2500 Measures 2500 Set Point 4000 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT TELECONTROL (CENTER AND PERIPHERALS) TRANSITGAS TRANSITGAS PIPELINE (CH) TRANSITGAS PIPELINE TELECONTROL SYSTEM (REMOTE CONTROL CENTER AND FIELD RTU CONTROLLERS) SYSTEM ARCHITECTURE SCADA, Front End 60870-5-104, and Oracle Historian Database for the Telecontrol Center. 2 HMI stations, videowall 3x2 monitor, Engineering workstation 37 redundant NTA RTU, for the monitoring along the pipeline 2 redundant RTU NTA with MODBUS interface toward the measuring systems, for the gas inlet station of Oltingue (France) and Wallbach (Germany) 1 OHF RTU (mini DCS) in the confluence node of (Rostolf), with regulation of low rates and pressions in the incoming and outcoming pipelines. 1 RTU NTA for the Ruswil pumping station MAIN FEATURES Pipeline monitoring and control system. Regulation of gas flow and pressure at the confluence node of Rostolf, interfacing with the measure systems located at the input nodes of the two lines from Germany (Wallbch) and France (Oltingue). 37 monitoring stations along the pipeline. Communication via the IEC 60870-5-104 protocol on a redundant ring LAN. I/O DATASET Digital Input 6000 Digital Output 1024 Measures 1200 Set Point 64 31/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DMS ASTEA MV/LV AND GAS NETWORK OSIMO (AN) AND RECANATI (MC) DMS AND TELECONTROL SYSTEM FOR GAS AND POWER DISTRIBUTION NETWORKS SYSTEM ARCHITECTURE SCADA, Front End, Report and Oracle Database based Historian. IEC 60870-5-101 e IEC 60870-5-104 protocols Operator Interface Subsystem composed by n. 2 operator HMI stations with integrated engineering functions. WEB HMI for the management of remote access via the WEB Integrated station for transmitting voice alerts to the available staff Firewall for the confinement of the SCADA system from the corporate network 1 RTU OHP, supplied by sdi, for primary substation (HV / MV) in Via Vici, Osimo MAIN FEATURES DMS system, complete with study and simulation station, for the electrical distribution networks of Osimo, Recanati and Polverigi, for a total of 3 primary stations, 2 satellite stations, 9 Enel exchange stations (HV/LV) and 885 secondary substations. Integrated generation of reports for the Authority. SCADA system of natural gas distribution network to Osimo, Recanati, Loreto and Monte Cassino for a total (initial) 6 REMI cabins. The system includes remote alarm function available to staff via the telephone network. I/O DATASET Digital Input 3000 32/86 Digital Output 1500 Measures 512 Set Point 512 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS SNAM RETE GAS COMPRESSION STATION GALLESE (VT) SUPERVISION AND CONTROL SYSTEM (DCS) COMPRESSION STATION OF NATIONAL GAS DISTRIBUTION NETWORK SYSTEM ARCHITECTURE DCS composed by two control nodes with physical I/O (simple and redundant) and with serial MODBUS RTU connections toward the 5 compressor units. Integrity control over the command circuit of the solenoid valve. Process Server in redundant hot backup configuration. Data Interfacing with the remote control centre. Time server for time stamp and time synchronization over the LAN, using NTP protocol. 2 control room operator HMI, each with dual monitor 1 mobile operator HMI 1 alarm management HMI 1 operator station dedicated to TC-5 compressor Interconnection to external remote diagnostic and tax measure for gas volumes systems MAIN FEATURES Automation and control of the compression station composed by 5 compression units. Interfacing to the remote control system, to the remote diagnostics system and to the tax measure system. I/O DATASET Digital Input 916+202 redundant+74 with integrity control Digital Output 138+214 redundant Measures 102+ 50 redundant Set Point 75+9 redundant 33/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA ENEL POWER PLANT TORRE DEL SALE PIOMBINO (LI) SUPERVISION SYSTEM OF CAPRAIA ISOLA THERMAL POWER STATION AND HARDWARE REVAMPING OFSDS SYSTEM OF PIOMBINO THERMAL POWER STATION SYSTEM ARCHITECTURE Piombino thermal power station Supervision system power units.3-4 integrated with the supervision and control of the power station Capraia Isola, composed by: • Redundant SCADA in hot backup configuration. • LAN HMI ethernet dual TCP/IP • Ethernet dual Field LAN TCP/IP • 4 HMI for control room of power units 3-4 operation. • 2 HMI for station offices operators. • 1 CONFIG engineering workstation for system parameters configuration. Capraia Isola thermal power station • SCADA single configuration • 1 STAR/Dual acquisition and control DCS station MAIN FEATURES Upgrade of control room and offices HMI stations. Upgrade of SCADA stations, with integration of signal and measures of the previous supervision and and control system. Functional integration in the DCS and in the Piombino Power Station of the supervision and control system data of the Capraia Power Station. I/O DATASET (Piombino Gr.3-4 + Capraia Isola) Digital Input 4500+150 34/86 Digital Output 32+16 Measures 2180+150 Set Point 10+10 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AND GATEWAY SELTA/TERNA TERNA ITALIAN POWER GRID HV/MV SUBSTATIONS HIGH VOLTAGE SUBSTATION AUTOMATION AND CONTROL (SAS SYSTEM) SYSTEM ARCHITECTURE Redundant Station Computer with the following functionalities: SCADA Gateway toward TERNA telecontrol centre and toward remote maintenance centre, using RTU with protocol IEC 61870-5-104 IO Server that uses protocol IEC61850 for the connection of all the bay units (provided by SELTA) of the substation. Oracle Database (redundant configuration) providing the following storing functionalities: alarms logs, events, SOE lists, disturbance recording (COMTRADE format) Soft PLC IEC 61131 for station level automation sequences (ASAT system) 1 Engineering workstation/HMI and 1 HMI station. 1 system printer, 1 hard copy printer MAIN FEATURES High Voltage Substation Automation for 17 TERNA substations for the Italian HV transmission grid. The substation topology is a double bus-bar topology with two or three Voltage section at 380, 220, 150 or 132 KV. The substations are of different size that ranges from 10 to 50 bays (mean size is 15 bay). The system is one of the first complete application of the IEC61850 protocol and system configuration standard. The IEC 61850 standard is used in LAN communication, connecting to SCADA the SELTA Bay Control Unit (BCU) e Bay Monitoring Unit (BMU), General Electric and SIEMENS Bay Protection Unit (BPU). The gateway function provides the connection to remote TERNA telecontrol centers; the protocol used is IEC 61870-5-104. Using the gateway function the station can be completely controlled from the CTI (Telecontrol Centre) of TERNA. I/O DATASET Digital Input from 2500 to 15000 Digital Output from 300 to 1500 Measures from 300 to 1800 35/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA GAVAZZI IMPIANTI WIND FARM MONTECATINI VAL DI CECINA WIND FARM SUPERVISION AND CONTROL . SYSTEM ARCHITECTURE Redundant SCADA providing local data historical archives, local and remote alarming, field data acquisition using STAR s.d.i. and 6 PLC SIEMENS S7 connected over redundant LAN. 3 HMI remote web connected stations. 2 local HMI stations, one of which provides also engineering functionalities. 1 Web Server for remote connection management 1 STAR device with redundant CPU for the management and control of the MV/HV power station of the wind farm Single System LAN , redundant fiber optic Field LAN MAIN FEATURES Local supervision and control of the wind farm composed by 6 wind turbines Data interface with the automation PLCs managing the 6 wind turbines; automation and control of the MV/HV power station. Remote supervision and control provided using web HMI connections, automated telephonic calls to the personnel in the case of warning/alarm. I/O DATASET Digital Input 832 36/86 Digital Output 62 Measures 232 Set Point 24 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS SIBA WASTEWATER TREATMENT PLANT OF CARINI (PA) DISTRIBUTED CONTROL SYSTEM (DCS) FOR THE WASTEWATER TREATMENT PLANT OF CARINI (PA) WITH OXYFUZZY REGULATION . SYSTEM ARCHITECTURE • • • • • • Redundant SCADA station (Master Station) connected to DCS node over redundant fiber optic LAN. 2 operator stations. 4 DCS nodes with I/O boards for the management of 2 industrial wastewater lines, 2 sewage treatment lines. 4 RTU microSTAR for the remote control of influent sewage (GSM connected) OxyFuzzy automation of the oxygenation process using an optimization of air pumping algoritm. Remote connection to the control system and automatic telephone calling to personnel in cases of alarm/warning (Remote Alarming) MAIN FEATURES DCS system that provides Supervision, Automation and Telecontrol of the industrial wastewater and sewage treatment site in Carini (PA). DCS plant distributed nodes are used for the control of the different stages constituting the water treatment process. Remote control of influent water is achieved using a GSM connected RTU A central SCADA is completed with the optimization of oxygenation process is provided using a new patented algorithm named OxyFuzzy. The functions provided by the system are: data acquisition and commend sending, operative management of the automation, regulation, protection and interlocking sequences. Analog measures and alarm limits elaboration with inhibition of command sequences. I/O DATASET Digital Input 608 Digital Output 280 Measures 72 Set Point 34 37/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA GATEWAY STOGIT 7 STOGIT GAS COMPRESSION AND TREATMENT STATIONS GAS VOLUME TAX MEASURES SYSTEMS FOR COMPRESSION AND TREATMENT STATIONS (STOGIT) SYSTEM ARCHITECTURE The system is installed in the compression and treatment stations of Ripalta, Sergnano, Settala, Minerbio, Sabbioncello, Cortemaggiore, Fiume Treste. In the 7 station are installed a total of 22 ultrasonic measure skid for fuel gas turbine and 31 lines of tax measure for the consumption of gas boiler of the plant. For each gas compression station a communication gateway between flow computers and plant DCS is provided. MAIN FEATURES Design, supply and installation of the systems of tax measure for gas volumes consumption in compression and treatment stations; approval of the systems installed (whole measurement chain) by the Ufficio Metrico Italiano (Italian Metric Authority). 38/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDISON PREMESA HYDRO POWER PLANT HYDROELECTRIC PLANT S.O.E, ALARMS AND MEASURES SYSTEM SYSTEM ARCHITECTURE The system is composed by: • 1 eXPert HMI-SCADA station connected to the acquisition and control device (STAR/OHF) and to the telecontrol remote centre • 1 STAR/OHF station for plant data acquisition and Seqeunce of Events functionalities (SOE) MAIN FEATURES Integrated system for alarm management, analog measures acquisition and SOE list management, related to the whole hydroelectric power plant. The system is connected, using a SELTA STCE apparatus, with the Integrated Remote Control System Centre of EDISON, that allows the remote management of the hydro power plants. The SCADA-HMI station provides also the system configuration and engineering functionalities. I/O DATASET Digital Input 480 Digital Output 0 Measures16 Set Point 16 39/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDISON HYDRO POWER PLANT CIVIDATE HYDRO POWER PLANT DCS (DISTRIBUTED CONTROL SYSTEM) AND TELECONTROL SYSTEM ARCHITECTURE The system is composed by: • 2 eXPert HMI stations • 1 eXPert EWS (Engineering Workstation) • Dual SCADA connected to the acquisition and control devices centre. • 4 STAR/OHF dual stations for the power generation units (2 stations) for the electric substation (1 station) and for the auxiliary systems (1 station) (STAR/OHF) and to the telecontrol MAIN FEATURES Complete management of the two hydro-power generation units, of the electric substation, and of the auxiliary services. Alarms and event management, analog measure acquisition and sequence of events recording for the whole power plant. The system is interfaced, using a SELTA-STCE apparatus, with the Integrated Remote Control System Centre of EDISON, that allows the remote management of the hydro power plant. The HMI stations and the Engineering Workstation, used for system configuration purposes, are provided. I/O DATASET Digital Input1600 40/86 Digital Output 288 Measures312 Set Point 16 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AND GATEWAY SELTA/TERNA TERNA HHV/HV SUBSTATIONS FOR ITALIAN TRASMISSION NETWORK HIGH VOLTAGE HHV/HV SUBSTATION AUTOMATION AND CONTROL WITH INTEGRATED GATEWAY (SAS) SYSTEM ARCHITECTURE Redundant Station Computer providing the following functionalities: • SCADA • Gateway to TERNA control centers used for remote control and maintenance; protocol used is IEC 61870-5-104 • IO Server uses standard IEC61850 for data communication within the HV station: connection between Station Computer and BAY units (Bay Control Units, Bay Monitoring Units and Bay Protection Units). • Oracle Database (redundant configuration) for event storage, SOE list, disturbance recording files. • Automation and control of operation sequences using IEC 61131 implementation. • 1 system printer, 1 hard copy printer 1 Engineering workstation and1 HMI workstation Remote HMI (up to 10 connections). MAIN FEATURES High Voltage Substation Automation, Control and Gateway toward tele-control and tele-maintenance for 21 TERNA substations of the Italian national Power Transmission Network. They are double bus-bar topology substations; with multiple Voltage section at 380, 220 and 132 KV. The total number of bays controlled for the single substation ranges from 10 to 60 bays; up to 4 transformers in parallel are managed. The system is a complete application of the IEC61850 protocol and system configuration standard. The IEC standard is used in LAN communication, connecting to SCADA the SELTA Bay Control Unit (BCU) e Bay Monitoring Unit (BMU), General Electric and SIEMENS Bay Protection Unit (BPU). The gateway function provides the connection to remote TERNA telecontrol centers; the protocol used is IEC 61870-5-104. Using the gateway function the station can be completely controlled from the CTI (Telecontrol Centre) of TERNA. I/O DATASET Digital Input from 2500 to 150000 Digital Output from 300 to 1500 Measures from 300 to 1800 41/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA EDISON CAVARZERE – MINERBIO METHANE GAS PIPELINE CAVARZERE-MINERBIO GAS PIPELINE REMOTE CONTROL SYSTEM SYSTEM ARCHITECTURE • • • • • • 2 SCADA I/O Server stations ( named Master Stations) interconnected by dedicated optical fiber Ethernet line, in order to build a dual system 3 remote HMI stations 2 OPC servers for the connection with Minerbio’s and Cavarzere fiscal measurement systems (respectively supplied by s.d.i. and Yokogawa ) 15 microSTAR RTUs located along the gas pipeline Dedicated-line connection between the RTUs and Minerbio’s and Cavarzere’s Master Stations Backup connection between the RTUs and Minerbio’s and Cavarzere’s Master Station managed via GSM/GPRS MAIN FEATURES Remote control of Minerbio Cavarzere gas pipeline DN 36”-84 Km. The control is effected by 15 acquisition and control peripheral (microSTAR), connected to the Master Stations via redundant dedicated line with backup line trough GSM/GPRS connections. The system manages the remote operator stations respectively located in Milan, Pescara and Ferrara. The two Master Stations, located in Cavarzere and Minerbio, guarantee the functioning of the system in redundant configuration with real-time alignment of the databases. Each Master Station is also connected to a local RTU (STAR QSC), that provides the local station I/O and interfaces to the central DCS. 42/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AZIENDA GARDESANA SERVIZI TLC POTABLE WATER DISTRIBUTION AND WASTE WATER COLLECTOR DISTRIBUTED SYSTEM FOR AUTOMATION, SUPERVISION AND TELECONTROL OF POTABLE WATER DISTRIBUTION AND WASTEWATER COLLECTION OF EASTERN GARDA LAKE SYSTEM ARCHITECTURE Redundant SCADA master/slave management with hot backup, external watch dog and arbitration unit (iEWDS). Operating system Windows-XP. N. 1 operator workstation (HMI) based on Windows XP, N. 1 engineering workstation used for the whole on line system configuration and maintenance (eXPert development). Remote operators connectivity (Web HMI). N. 2 on-line printers used for journaling logging, reports, hard copy.. N. 90 RTU s.d.i µSTAR for data acquisition and commands to remote sites; connection using telephonic switched network (PSTN e ISDN) or cellular network (GSM); connection using radio modem or dedicated line to lower hierarchy RTU. MAIN FEATURES Supervision and Telecontrol for water management of Azienda Gardesana Servizi (AGS): the system provides tele-control functionality for the potable water distribution network (in the district of Garda, Peschiera, Valeggio, Castelnuovo, Bardolino, Lazise) and for waste water collection in the east side of Garda Lake. Telecontrol devices (MTU and RTU) are organized in Local Area Networks and are configured with distributed control logic. The system provides also to automatically send telephone calls, text messages (SMS) and e-mail regarding alarm signals to maintenance personnel, remote access to the system is allowed using web enabled HMI. I/O DATASET Digital Input 2400 Digital Output 1200 Measures 1200 Set Point 300 43/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDIPOWER TERMOELECTRIC POWER PLANT S.FILIPPO DEL MELA gr. 1-2 ALARMS, SUPERVISION AND CONTROL SYSTEM FOR POWER GENERATION GROUPS 1-2 SYSTEM ARCHITECTURE Alarms acquisition and visualization system. Supervision and control system composed by:: SCADA in redundant configuration with hot backup. Redundant HMI LAN ethernet TCP/IP Redundant Field LAN ethernet TCP/IP 4 HMI workstation; 2 dedicated to SdS points visualization 2 for alarms visualization. 1 CONFIG engineering workstation used for system parameters configuration 4+2 STAR Redundant DCS nodes for data acquisition and control Marshalling cabinets. MAIN FEATURES Alarms acquisition and visualization; HMI station and SCADA units for the integration of signals and measures comng from the supervision and control system. 7 DCS nodes for the supervision and control of generation groups. Integration of plant’s auxiliary systems via OPC Server and Client. I/O DATASET Digital Input 900 44/86 Measures 1000 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA CPL CONCORDIA EDISON GAS – MINERBIO MEASUREMENT STATIONS MINERBIO’S GAS MEASUREMENT STATION PROCESSING AND MANAGEMENT SYSTEM . SYSTEM ARCHITECTURE 2 operator stations (HMI) and system printer for the printing of official, control and event list report. 1 redundant SCADA for the interface with all the fiscal measurement and gas quality equipments and respective processing. 1 OPC server (redundant) for the connection with the remote control system 2 EWDS for serial lines switching toward the flow computer system Redundant system and field networks 1 eXPert QSC RTU for the acquisition Field LAN interface to the Flow Computers RS485 Serial lines interface toward the gas quality meters MAIN FEATURES Acquisition, processing and management of data regarding the capacity, volumes and quality of gasses in transit trough Edison Gas Minerbio measurement station, for fiscal and plant management purposes. Signal acquisition from flow computers, gas chromatograph, densimeter, dew point meters and valves. Management of the controls toward the measurement lines valves. Processing of average and total capacity data, alarms management and creation of official and control reports. Interface with the remote center. 45/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA SELTA ENDESA TELECONTROL CENTERS TELECONTROL AND ENERGY MANAGEMENT (EMS) OF ENDESA POWER PLANTS IN ITALY SYSTEM ARCHITECTURE: Telecontrol and Bidding control room (Telecontrol Center of Terni) composed by 2 HMI station and 1 graphic wall. Hydro and Wind Power plants control room (Telecontrol Center of Terni) composed by 2 HMI station and 1 graphic wall. Engineering control room composed by two Engineering Workstation (HMI/Config) respectively related to hydro and wind plants . Web server for remote Web HMI. Redundant SCADA, redundant Front End (I/O Server IEC 60870-5-101protocol), EMS/Historian. Disaster Recovery system in Pomezia composed by 2 HMI stations, SCADA, EMS/Historian e Front End. Connections using WAN RTU network, GRTN network, Terna SCTI network. MAIN FEATURES: Supervision and remote control of thermal power stations, hydroelectric and wind power plants of ENDESA Italia (19 hydro, 11 mini-hydro, 5 thermal , 4 wind power plant, reaching a total number of 75 power units managed by the EMS system). Remote management and regulation of the plants based on production schedules provided by GSE (Gestore dei Servizi Elettrici). Implementation of calculation of production cost. I/O DATASET Digital Input 10000 46/86 Digital Output 2500 Measures 2500 Set Point 4000 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA EMERSON – SNAM RETE GAS 10 GAS COMPRESSION PLANTS SNAM RETE GAS FISCAL MEASUREMENT SYSTEMS OF COMBUSTIBLES GAS VOLUMES FOR SNAM RETE GAS PLANTS SYSTEM ARCHITECTURE The system is provided for 10 gas compression plants: ENNA, MELIZZANO, MESSINA, TARSIA, MONTESANO, MASERA, ISTRANA, MALBORGHETTO, GALLESE, TERRANOVA Each system is composed by 2 SCADA stations with measures acquiring features from flow computers, energy meters and gateways. The SCADA system is connected to up to 5 flow computers produced by s.d.i. per system (FIMIGAS VESCOM 3C) Complete supply of the various measurement lines (fuel gas unit, fuel gas heaters, water lines for the heaters). MAIN FEATURES Basic and detail planning for the realization of fiscal measurement systems of combustible gas volume in the 5 compression plants; installed systems approval (whole measurement lines) on behalf of the Ufficio Metrico Italiano. Procurement for the realization of the fiscal measurement systems, and their mechanical and electro-instrumental realization. Interface with : • • • Station Control System SCS Informative system to acquire gas quality data from Customer Withdrawal Homogeneous Areas (AOP) DEC Information System for central exercise data transmission I/O DATASET Digital Input 10000 Digital Output 2500 Measures2500 Set Point 4000 47/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA ENI GAS AND POWER - SCOGAT TRANSTUNISIAN GAS PIPELINE (TRANSMED) REMOTE CONTROL OF THE TUNISIAN PART OF TRANSMED GAS PIPELINE SYSTEM ARCHITECTURE: Main Remote Control center composed by : • SCADA I/O Server with dual configuration and hot backup • Video wall • 2 operator stations (each one with 3 monitors) • Web server for remote web HMI • HDR station for filing data in chronological order • Engineering workstation • Telecommunications and system diagnosis operator station (2 monitors) Remote Control center with disaster recovery feature composed by : • SCADA I/O Server with single configuration, operator station (3 monitors), telecommunications and system diagnosis operator station (2 monitors), HDR station for filing data in chronological order, Web server for remote web HMI 42 iSC RTUs for the acquisition of measures along the gas pipeline and remote control of pumping stations, connected with the 2 centers by dedicated lines and backup radio link (redundant connection per center) MAIN FEATURES: Monitoring and remote control of the gas pipeline that connects Feriana (boundary with Algeria) to Capo Bon (beginning of TRANSMED’s Mediterranean part) and respective pumping stations. Interface by RTU of 3 DCS produced by s.d.i. and 2 produced by ABB, in the pumping stations. Communication system on-line diagnosis I/O DATASET Digital Input 6384 48/86 Digital Output 1024 Measures 1200 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS SNAMPROGETTI SBIKHA, SBEITLA E KORBA GAS COMPRESSION PLANT AUTOMATION, CONTROL AND MONITORING SYSTEM OF THE 3 COMPRESSION PLANTS OF THE TRANSTUNISIEN GAS PIPELINE (TRANSMED) SYSTEM ARCHITECTURE: 3 DCS Systems for the gas compression plants Sbikha, Sbeitla e Korba. Each system is composed by: • 3 STAR OHF nodes, each one with redundant CPU and hot backup, redundant LAN connections, respectively dedicated to common plant management logics (LE1), compressors logics (LE2) and regulation logics (LR). • 1 user station (2 monitor) • 1 user/engineering station (2 monitor) • 1 portable user station • 1 I/O Server (Gateway) for the connection with the remote control centers ( the Main one and the recovery one, both made by s.d.i.) • 3 printers (events, alarm and Hard Copy) • 1 interface system to the remote conduction dedicated RTU, composed by a I/O Server with dual configuration MAIN FEATURES: Acquisition and management of the automation, protection and interlock operating sequences. Processing of analog signals with alarm with the production of threshold alarms or consent to the remote control sequences. Redundant digital Inputs and integrity check on control relays. Use of LOOP boards for PID adjustments. Interface to Compressors panels by serial MODBUS. Running of the plant by remote control using the interface with the remote-operations system (I/O Server and remote control RTUs); on spot running by monitoring stations (DCS HMI). Chronological report feature with resolution of 5 milliseconds. Remote self-diagnosis feature of the remote control. I/O DATASET (for each DCS) Digital Input 750 Digital Output 200 Measures180 Set Point 26 49/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS e SCADA ECOVENETA WASTE WATER NETWORK ORBETELLO LAGOON SUPERVISION, AUTOMATION AND TELECONTROL SYSTEM OF COLLECTION AND PURIFICATION NETWORK IN LAGOON AREA OF ORBETELLO SYSTEM ARCHITECTURE Supervision e telecontrol system composed by: Redundant SCADA station with integrated Historian, Call Center Management e Remote Alarming for telecontrol of water pumping station (63 telecontrol peripherals RTU) and supervision of the purifier plant DCS. • • • 2 HMI Stations 1 HMI Config Station remote HMI web connected Purifier plant DCS system composed by: • 4 STAR OHF redundant stations connected over dual Ethernet TCP/IP MAIN FEATURES Supervision, automation and telecontrol of wastewater collection and treatment of lagoon waters of the municipalities of Orbetello and Monte Argentario. Automation and control of the purifier of Terrarossa, carried out by DCS stations (STAR) connected to the central system via redundant ETHERNET network with TCP / IP. Remote control of the water pumping station carried out by RTU using the Modbus protocol. Available Personnel Management and integrated call center via voice alert/call messages to staff available on duty, to report significant failure or malfunction of equipment, including integrated management of reports of failure, submitted by citizens. I/O DATASET Digital Input 2332 50/86 Digital Output 931 Measures 494 Set Point 43 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA ACSM - COMO POTABLE WATER AND GAS DISTRIBUTION TELECONTROL OF POTABLE WATER AND GAS DISTRIBUTION NETWORK IN THE CITY OF COMO AND RELATED DISTRICT SYSTEM ARCHITECTURE • • • • • • Telecontrol Centre in redundant hot backup configuration SCADA, I/O Server Historian e 2 HMI station with dual monitor; all functionalities are provided by a redundant server. Storage Manager Station providing data storage, elaboration visualization and analysis. The same workstation provides to all engineering function of the whole system. 68 RTU (30 nanoSTAR, 30 microSTAR, 8 STAR/ISC) connected to the control center using ISDN, PSTN, dedicated lines and GSM wireless connection. Management of ISDN lines as backup of dedicated lines Integration of a MOVICON pre-existent control system (used for the management of the water depuration) interfaces through MODBUS protocol (3000 data points) MAIN FEATURES Supervision and telecontrol of potable water and gas distribution for the Como city and district. RTU, all produced by s.d.i., are connected to the control centre using different types of lines (ISDN, PSTN, dedicated) and GSM wireless connections. The protocol used is standard IEC 60870-5-101. Connection using MODBUS protocol to a pre-existent depuration automation system. I/O DATASET Digital Input 750 Digital Output 250 Measures 500 Set Point 30 51/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA STOGIT GAS STORAGE PLANTS MONITORING AND REMOTE CONTROL SYSTEM FOR GAS STORAGE PLANTS (STS) SYSTEM ARCHITECTURE 2 remote control centers in disaster recovery configuration Operative composed by 16 monitors ( 2 for each remote-controlled plant ), that could be dynamically relocated in other plants. Dual SCADA and Historian based on Oracle architecture. 8 Front Ends ( FEP ) that acquires data from compression and treatment plants of each site The composition of each Front End depends on the various type of DCS system in the plants. MAIN FEATURES Monitoring and remote control of the 8 storage plants managed by STOGIT. In each site there are a compression plant and a treatment plant. The Font Ends produced by s.d.i. interface with DCS in the plants via OPC and MODBUS interface, and/or third parts protocols; each plant is characterized by peculiarities that are solved with specific interfaces by Front Ends. Each Front End communicate with both centers (primary and backup for disaster recovery). In each center the user stations can take control of the remote-controlled sites; dynamic process database is centralized in the center SCADA system ( everyone in dual configuration), while historical data are stored in the filing station that lean against an Oracle Server. The communication with the various centers is based on the IEC 60870-5-104 standard. I/O DATASET Digital Input 20000 52/86 Digital Output 5000 Measures10000 Set Point 5000 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AND LEAK DETECTION EMERSON PROCESS IRANIAN GAS PIPELINE AHWAZ SCADA AND LEAK DETECTION SYSTEM – AHWAZ PLANT SYSTEM ARCHITECTURE 1 eXPert HMI-SCADA station 6 RTU (µSTAR) installed on the pipeline in LBV stations Redundant photovoltaic (solar cells) power supply systems for RTUs Redundant radio modem connection between SCADA and RTUs; the connections are managed using fail over and load balancing policies. Serial Modbus connection between SCADA and Emerson DCS. MAIN FEATURES Leak detection system monitoring a 95 km long 12” acid gas pipeline. The measurement points are placed in 6 LBV station placed over the pipeline. System works on-line to identify leak along the pipeline and providing also supervising functionalities. Leak detection is made by a mathematical model that simulates all plant components and analyses all differences between measured values and expected values. This simulator is based on WIN/GIPS (Graphical Interface Process Simulation) real-time mathematical modeling software and it is integrated into the eXPert suite. The main functionalities provided are: • Data acquisition and validation; • Real time pipeline model; • Pipeline simulator; • Pipeline leak detection and localization algorithms; • Limit values management; • Operator alarms generation and diagnostic functions. The system is integrated into the Emerson DCS system installed at Ahwaz; all process variables exchange is done using Modbus protocol 53/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AEM S:P:A: HYDRO POWER PLANTS VALTELLINA VALTELLINA HYDRO POWER PLANTS TELECONTRL SYSTEM AND REMOTE GMS/EMS FUNCTIONALITIES SYSTEM ARCHITECTURE Redundant SCADA Server– hot backup master/slave management, Real Time and relational database (Oracle, for data archiving purposes) time synchronization with external GPS. 4 local HMI workstations, one of them used also as system engineering worstation (HMI/CONFIG), connected over redundant LAN Ethernet TCP/IP. 2 workstation connected to the corporate network and to the control system, used as generation management system (GMS) and energy management system (EMS). 1 redundant I/O SERVER for the communication with specific remote operation telecontrol protocols (TIC 1000, TIC 2, e AS 511). 1 I/O SERVER DUALE for the communication with standard remote operation telecontrol protocols (IEC 60870-5101). MAIN FEATURES Remote control and supervision of hydroelectric power plants in Valtellina. Energy trade, and regulating levels of load distribution of the group of companies (AEM MI / ASM BS / AGSM VR) using EMS/GMS functionalities. I/O DATASET Digital Input 10000 54/86 Digital Output 2048 Measures 1200 Set Point 256 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT RTU 3G SNAM RETE GAS NATIONAL GAS DISTRIBUTION NETWORK TELECONTROL REMOTE TERMINAL UNIT (RTU) OF THIRD GENERATION FOR THE PRIMARY NATIONAL SNAM GAS NETWORK GENERAL SPECIFICATIONS RTU series STAR iSC rack 19. Redundant CPU Redundant power supply Modular intelligent I/O boards: • iTS board: 16 digital input with integrated channels integrity monitoring • iTC board: 8 digital output (command) with integrated solid state relays of each channel monitoring • iTM board: 8 analog input (measure) with high common mode and normal mode rejection ratio • iSER board: 4 serial port for MODBUS connection toward DCS systems and/or field devices Connection with national dispatching centre SNAM over redundant dedicated lines. NUMBER OF DEVICES SUPPLIED Up to now 75 RTU devices in different sites along the national primary distribution network MAIN FEATURES: Monitoring and remote management of gas transmission plants in the primary gas distribution network with direct I/O or data acquisition from local plant DCS. Data communication to the remote National Dispatching Centre (SNAM) CONTROLLED POINTS SINGLE RTU (DEFAULT) Digital Input 32 Digital Output 8 Measures 8 55/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT STAR RTU AEM MV/LV DISTRIBUTION NETWORK TELECONTROL REMOTE TERMINAL UNITS (RTU) FOR THE MV/LV SUBSTATIONS IN MILAN AREA SYSTEM ARCHITECTURE 2 I/O Server (front end functionalities) for field data acquisition via a bank of ISDN modems from RTU μSTAR/MBT using IEC 60870-5-101 transmission protocol. The two servers are in redundant decentralized configuration. Connection, via ethernet LAN (protocol IEC 60870-5-104) with the pre-existing Telegyr STUX-STM 2000 telecontrol system. 700 RTU μSTAR/MBT used for the telecontrol of MV/LV substations of type ENEL (284) and type AEM (416). The modem, connected via serial RS232C line with RTU, can be of type GSM Dual Band or PSTN. Each device is power suppied with an energy station, with monitoring and diagnostic funcions of battery charge, at main power of 230 Vac., The diagnostic informations are collected at RTU level using a serial RS232C connection. A group of accumulators, 2 or 4 depending on the auxiliary output voltage (24 VDC or 48 VDC) requested in the substation, is sized to ensure the continuity of operations in case of absence of mains supply (up to 12 hours of operation with at least 30 operations). MAIN FEATURES Remote Control of MV/LV of medium voltage distribution network substations (AEM and Enel) in the municipalities of Milan and surrounding municipalities. Interfacing with the current telecontrol system via IEC 8705-104 protocol. I/O DATASET (for each RTU) Digital Input 64 or 48 56/86 Digital Output16 or 12 Measures 8 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS AND SCADA AGOS ITAFINCO CED BERNINA AND LANCETTI DATA CENTER AUXILIARY SYSTEMS DIAGNOSTICS SYSTEM ARCHITECTURE 2 STAR OHF redundant DCS nodes, for data acquisition and regulation functions, 2 SCADA - I/O Server workstations for data acquisition, regulation and local HMI functions (Expert STOP/PC Stations). 2 remote HMI stations Oni Expert STOP/PC workstations are also present the following functional modules: • Expert Remote Alarming for alarm notification using telephone or SMS connection personnel on duty.. • I/O Server For the communication between SCADA and STAR OHF nodes on Ethernet 10/100 Mbit LAN. • HDR modules for the periodic recording of the data in the archive files.. The data thus stored can then be displayed via the HMI application. MAIN FEATURES Two data centers monitoring and alarm management. Is carried out environmental and power diagnostics, to ensure the proper functioning of the servers hosted in the data centers. Is also monitored the air conditioning system and intrusion detection. The system is equipped with a telephone call to the available personnel in the case of alarms detection. I/O DATASET Digital Input 2700 Digital Output 32 Measures 170 57/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA SELTA/TERNA HHV/HV TERNA SUBSTATIONS TERNA HHV/HV SUBSTATION AUTOMATION AND CONTROL (SICAS STANDARD SYSTEM) SYSTEM ARCHITECTURE Redundant Station Computer providing the following functionalities: • SCADA • Gateway to TERNA control centers used for remote control and maintenance; protocol used is IEC 61870-5-104 • IO Server uses standard IEC61850 for data communication within the HV station: connection between Station Computer and BAY units (Bay Control Units, Bay Monitoring Units and Bay Protection Units). • Oracle Database (redundant configuration) for event storage, SOE list, disturbance recording files. • Automation and control of operation sequences using IEC 61131 implementation. • 1 system printer, 1 hard copy printer 1 Engineering workstation and1 HMI workstation Remote HMI (up to 10 connections). MAIN FEATURES High Voltage Substation Automation, Control and Gateway toward tele-control and tele-maintenance for 5 TERNA substations of the Italian national Power Transmission Network. They are double bus-bar topology substations; with multiple Voltage section at 380, 220 and 132 KV. The total number of bays controlled for the single substation ranges from 10 to 80 bays; up to 4 transformers in parallel are managed. The system is a complete application of the IEC61850 protocol and system configuration standard. The IEC standard is used in LAN communication, connecting to SCADA the SELTA Bay Control Unit (BCU) e Bay Monitoring Unit (BMU), General Electric and SIEMENS Bay Protection Unit (BPU). The gateway function provides the connection to remote TERNA telecontrol centers; the protocol used is IEC 61870-5-104. Using the gateway function the station can be completely controlled from the CTI (Telecontrol Centre) of TERNA. I/O DATASET Digital Input 120x80 58/86 Digital Output 20x80 Measures 10x80 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA SELTA/TERNA SOTTOSTAZIONI TERNA HV/MV HV/MV SUBSTATION MONITORING AND REMOTE CONTROL (MRE) SYSTEM ARCHITECTURE Station Computer with thw following functionalities: • SCADA • IO Server MMS UCA.2 protocol for tyhe connection with SELTA bay control units (IED) • 1 HMI/Engineering workstation ed 1 HMI station; • 1 system printer MAIN FEATURES Modular system used da utilizzarsi for alarm visualization, sequence of events, disturbance recording files (DFR) download and archiving, for HV/MV substation of TERNA. The system has been installed in more than 50 HV/HHV plants of Terna. The protocol used is MMS UCA.2; it allows the acquisition from SELTA MU devices (Monitoring Unit). The system configuration is based on an XMLformatted file, that is automatically imported for the SCADA database definition and creation. The main function are: • • • Data and DFR files acquisition from IEDs Sequence of events acquisition and recording (SOE lists) Alarms acquisition and elaboration The system is designed to control large stations (about 80 functional units). I/O DATASET Digital Input 120x80 Digital Output 20x80 Measures 10x80 59/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT SIMULAZIONE ENEL RICERCA C:LE GRAZIA DELEDDA SULCIS CIRCULATING FLUIDIZED BED BOILER MODEL FOR THE DINAMIC SIMULATOR OF THE SULCIS POWER PLANT SYSTEM ARCHITECTURE Plant: Circulating Fluidized Bed (CFB) combustion process; boiler with thermal power of 790 MW and 340 MW. The CFB plant simulator was developed and installed by Enel Ricerca; it was aimed to support the technical personnel during plant project verification and plant commissioning. Sdi provided the simulation software (WinGIPS), has collaborated for modeling analysis, specific software development, and supplied the HMI operator interface . Simulatore: the dynamic simulator is constituted by a set of sub-models (task) managed by various types of solvers. • process dynamic models and equation, based on the product WinGIPS of Sdi, a network-oriented thermo fluid dynamics simulation toolkit • general purpose dynamic models and control DATI CARATTERISTICI Variables num. 200000 60/86 Equation Number 7000 Olver 6 Year/Man Uomo Sdi for the development of the system eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DMS SELTA / AGSM VERONA MV/LV DISTRIBUTION NETWORK DMS (DISTRIBUTION MANAGEMENT SYSTEM) AND MV/LV SUBSTATIONS TELECONTROL SYSTEM ARCHITECTURE: Control room with 3 eXPert HMI stations with 2 monitor; one HMI with additional engineering and configuration functions 3 additional HMI in offices 1 redundant SCADA 1 redundant I/O Server 1 SIMULATOR station Redundant system network Multiple modems and switches for the management of communication lines toward RTUs MAIN FEATURES: The system provides, besides the ordinary telecontrol, SCADA and HMI functions, also distribution management system (DMS) functionalities, for the MV/LV energy distribution system of Verona. The DMS system manages all topological network information, calculates the actual network status, considering all data acquired from RTU and/or coming from operators input, and individuates the network point of failure. The DMS system is completed by two integrated software packages: the RIRE software (electric network interruptions recording) that allows to log the interruptions and to calculate the quality of service of the electric distribution network. the simulator that allows the simulation of the network behavior starting from previously recorded network statuses (snap-shots) and allows the testing and verify of operating sequences. Interruption logging is used also in connection with the simulator station allowing the creation of simulated scenarios that are useful for study and documentation purposes. The system manages a whole of 2400 MV/LV stations. I/O DATASET Digital Input 12000 Digital Output 9000 Measures 0 Set Point 0 61/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AND SIMULATION GREENSTREAM ENI GROUP LGTS LIBYAN GAS TRANSMISSION SYSTEM SCADA AND PIPELINE LEAK DETECTION SYSTEM – GREENSTREAM PLANT DUAL FRONT-END SYSTEM SICILY GPS SOCRATE METERING SYSTEM ECIS DCS SYSTEM S S LAN ETHERNET S EWDS EWDS RS232 M M RS232 RS232 M MODEM SERIAL LINES - 19.200 BAUDS - MODBUS RTU PROTOCOL MODEM Pubblic switched Telephon lines DANIELS METERING SYSTEM NUOVO PIGNONE ABB DCS SYSTEM S LDS SYSTEM ENG. W/S 21" CRT 21" CRT NOT IN SUPPLY OPERATOR STATION DUAL SCADA SYSTEM 21" CRT GPS 21" CRT MODEM MODEM PRINTER SERVER S LAN ETHERNET EWDS RS485 M RS232 M LIBYA SERIAL LINES - 19.200 BAUDS - MODBUS RTU PROTOCOL NEW LGTS SCADA & LD SYSTEM LAYOUT SYSTEM ARCHITECTURE 2 eXPert HMI-SCADA station (hot-backup), 1 engineering workstation ed 1 leak detection station installed at the Libyan pipeline end-position (Mellitah); 1 RTU sited in Gela in order to connect local DCS and handle communications with Libyan terminal MAIN FEATURES Gas (average 8 BSCMY Billion Standard Cubic Meter per Year) extracted in Libya is redirected toward Italy through a pipeline about 550Km long which runs on the bottom of the sea at a maximum depth of 1.160 meters; a compression station is located in Mellitah (Lybian coast), gas is pumped into national Italian network in Gela (Italian coast). The only measurement points are located on the coasts. System works on-line to identify leak along the pipeline and providing also supervising functionalities. Leak detection is made by a mathematical model that simulates all plant components and analyses all differences between measured values and expected values. This simulator is based on WIN/GIPS (Graphical Interface Process Simulation) real-time mathematical modeling software and it is integrated into the eXPert suite. The system is integrated into the DCS architecture installed at Mellitah and Gela supervising stations; it receives via Modbus protocol all process variables. 62/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDISON HYDRO POWER PLANTS OF BATTIGGIO AND ESTERLE HYDRO POWER PLANT ALARMS, MEASURES AND SOE LISTS SYSTEM SYSTEM ARCHITECTURE For each hydroelectric power plant the system is composed by: 1 eXPert HMI-SCADA workstation connected to the DCS acquisition and control nodes (STAR/OHF) and to the remote tecontrol system via SELTA STCE telecontrol device. 3 DCS nodes STAR/OHF dedicated to acquisition and SOE functionalities. MAIN FEATURES For each of the 2 hydroelectric power plant an integrated alarm, analog measures and sequence of events (SOE) system was provided. The system is also interfaced, via a SELTA STCE telecontrol device, to the integrated Supervisione and Telecontrol system of Edison, that allows the remote management of hydro power plants from the Operations Center of Bolzano. The HMI-SCADA station, has also engineering workstation functionalities. I/O DATASET BATTIGGIO Digital Input 810 Digital Output 0 Measures 76 Set Point 0 Digital Output 0 Measures120 Set Point 0 I/O DATASET ESTERLE Digital Input 1100 63/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA/DMS SELTA /ASM BRESCIA MV/LV DISTRIBUTION NETWORK DMS (DISTRIBUTION MANAGEMENT SYSTEM) E TELECONTROL OF MV/LV SUBSTATIONS SYSTEM ARCHITECTURE 4 eXPert HMI station, one of them with engineering functionalities (CONFIG); 10 remote HMI (wireless connected using GSM) for maintenance and support personnel. 1 redundant SCADA station 1 redundant I/O Server and multiple modems and switches used for communication lines management toward RTUs 1 Simulation station interfaced to an Historian station with specific functionalities of network asset snap shots memorization. MAIN FEATURES The system provides, besides the ordinary telecontrol, SCADA and HMI functions, also distribution management system (DMS) functionalities. The controlled MV/LV energy distribution network covers Brescia and the Salò valley. The DMS system manages all topological network information, calculates the actual network status, considering all data acquired from RTU and/or coming from operators input, and individuates the network point of failure. The DMS system is completed by two integrated software packages: the RIRE software (electric network interruptions recording) that allows to log the interruptions and to calculate the quality of service of the electric distribution network. the simulator that allows the simulation of the network behavior starting from previously recorded network statuses (snap-shots) and allows the testing and verify of operating sequences. The system manages 2400 MV/LV substations (600 of which remote controlled) situated along the Salò Valley and 1500 MV/LV substations (187 of which remote controlled) in Brescia. Are also managed the connected HV/MV substations, and in Salò Valley, the whole HV network. Are controlled totally 20 HV substations. The complete management of the network status required a local database (additional in respect to acquired data) of 66000 calculated digital points, 8000 analog points,17000 strings and 3000 structured data points. I/O DATASET Digital Input 15700 64/86 Digital Output 9900 Measures 250 Set Point 50 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT/RTAP HP-UX STOGIT GAS STORAGE PLANTS STOGIT REMOTE CONTROL OF UNDERGROUND GAS STORAGE PLANTS SYSTEM ARCHITECTURE 4 SCADA RTAP stations in redundant configuration with 9 Front End elements (hot-backup) 1 Front End station in redundant configuration (MODBUS) to connect compression gas station 16 HMI stations (connected with SCADA in a modularity of 4) 2 Engineering Workstation 1 storage station on relational db (ORACLE) with a WEB interface used to have an Intranet access 4 networks composed by RTUs ( s.d.i. STAR) used to handle signals, measures, commands and set-points at the compression stations; 3 networks are composed by 3 devices, the fourth is composed by 6 devices. MAIN FEATURES Remote control of underground gas storage plants located in Sergnano, Ripalta, Settala, Cortemaggiore, Fiumetreste, Brugherio, Minerbio, Sabbioncello and corresponding compression stations. I/O DATASET In this plant are remotely controlled about 80000 signals. 65/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT SIMULAZIONE ENEL C.LE BRINDISI SUD DYNAMIC TRAINING SIMULATOR FOR DESOLFORATION PLANT OF UNIT 1 OF THERMOELECTRIC POWER PLANT OF BRINDISI SUD SYSTEM ARCHITECTURE PLANT: flue gas desulfurization process of a coal-fired thermoelectric power plant. The fumes are treated in two absorption columns with a spray suspension of limestone. The sulfur absorbed, once precipitated with calcium in the form of gypsum, is extracted from the absorber reaction tank and treated to be sold. Hardware platform simulator: workstation Compaq ES 40 with OSF1 UNIX operating system Simulation Software: simulation environment run-time alterLego, able to accommodate task process and regulation implemented with solvers WinGIPS and Legocad. MAIN FEATURES Introduction in the simulation environment WinGIPS of Sdi of the treatment of physical and chemical phenomena such as evaporation, absorption, dissolution, precipitation, dust collection, irreversible and reversible reactions with finite kinetic and equilibrium. Study and implementation in simulation environment WinGIPS of: mathematical models of innovative components of the system such as: reaction column and tank pre-absorber and absorber main hydrocyclones, tanks in the open air, the implementation of the models is based on the principles of conservation of mass, energy and momentum tables of the thermodynamic properties of the exhaust fumes and of the liquid suspension of limestone Implementation with graphical configurator and solver WinGIPS of process tasks that constitute the mathematical model of almost all of the plant. Analysis of the regulation system and modeling of the chains of control necessary for the management of the plant and to the realization of operational sequences; tuning of the regulation systemImplementation of HMI and visualization of plant synoptic representation TYPICAL DATA Num. variables 60000 66/86 Num. Equations 20000 Year Sdi: 4 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA / SIMATIC S7 CESI HYBRID POWER GENERATION EXPERIMENTAL PLANT AUTOMATION AND CONTROL SYSTEM FOR EXPERIMENTAL HYBRID CELL – MICRO TURBOGAS POWER GENERATION SYSTEM ARCHITECTURE Automation and control are implemented using eXPert system. eXPert is configured using the following components: SCADA - Soft PLC (in redundant configuration) with I/O server functionalities: • toward ProfibusDP connection to Siemens I/O modules • toward Micro-turbogas turbine Bowman with MODBUS serial connection Two HMI Station, one of which with Soft Logic Editor for automation functions editing using IEC1131 standard language 3 Rack Cabinets with ET 200M modules (SIMATIC S7 SIEMENS) MAIN FEATURES Whole plant supervision and control. The following functionalities have been developed using SOFTPLC functions: • Data acquisition, operative sequences management, protection and inter-blocking of plants. • Commands, inter-blocking for the different plant’s devices. • Analog signal processing with threshold alarm generation. • 52 regulation loops, with cycle time of 500 msec, completed by automatic/manual, remote/local function mode. I/O DATASET Digital Input 304 Digital Output 192 Measures 424 Set Point 64 67/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA E STAR RTU ENEL PRODUZIONE POWER COGENERATION PLANTS REMOTE CONTROL SYSTEM FOR COGENERATION PLANTS SUPERVISION SYSTEM ARCHITECTURE Remote control central station implemented using eXPert. eXPert has been configured using the following components: • Communications with µSTAR using I/O server functions • Run Time Environment for SCADA, HMI and Historian subsystems • Integrated Software Tools for soft logic developing using IEC1131 standard and system configuration eXPert is installed on a PC architecture, rack mounted communication devices are used. 60 RTUs µSTAR distributed over the entire Italian territory using a GSM connection to communicate with the supervising centre. MAIN FEATURES System supervises all remote control functions of cogeneration devices produced by ENEL. These devices are connected via a GSM network. RTUs can be configured directly from the supervising system and operators receive notification of all alarms and production data for each single device. RTUs are interfaced directly with local power generating unit, manage local plant work according with electric and heat demand, manage plant start and stop, manage historical data recording. Central supervising station use a set of modems to connect RTUs, this guaranties a good way to expand system in term of RTU number. I/O DATASET Digital Input 16x60 68/86 Digital Output 8x60 Measures 8x60 Set Point 2x60 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT STAR RTU SNAM RETE GAS REGIONAL GAS NETWORK REMOTE CONTROL DEVICES SUPPLY FOR PRESSURE REDUCTION PLANTS AND MEASURE POINTS FOR SNAM GAS NETWORK (RID AND PIDA) DEVICES TYPES nanoSTAR devices supplied in two different configurations: • RID to supervise and control reduction pipeline points (6 AI + 8 DI) • PIDA to supervise pressure measurement pipeline points (2 AI + 2 DI) with pressure transmitters Electric power supply or photovoltaic supply with a battery Connection with Maintenance Centre and National Distribution Centre (NCS) using an integrated GSM modem NUMBER OF DEVICES SUPPLIED 650 RTUs distributed over the entire Italian territory. MAIN FEATURES Monitoring methane gas pressure over particular regional points (PIDA). Monitoring methane flow and temperature at the pressure reducing plants located over the entire Italian gas network (RID). I/O DATASET (FOR EACH DEVICE) Digital Input 2-8 Digital Output 0 Measures 2-6 Set Point 0 69/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT/RTAP HP-UX ENI DIV E&P C.LE GAS DI CROTONE SCADA CONTROL SYSTEM FOR GAS TREATMENT PLANT LOCATED IN CROTONE AND 7 CONNECTED OFF-SHORE PLATFORMS SYSTEM ARCHITECTURE 1 SCADA RTAP redundant system connected to a redundant Front End produced by third party. Front End stations acquire plant and off-shore platform variables. 6 HMI stations, one of them is dedicated to configuration and maintenance operations (engineering station). MAIN FEATURES The system acquire Crotone plant information using a redundant Front-End connected to a redundant Ethernet LAN. Other systems connected are: Hera Lacinia and Linda power plant with Cluster A,B,C; Luna A, Luna B, Hera Lacinia 14, Hera Lacinia Beaf off-shore platform. I/O DATASET Digital Input 3222 70/86 Digital Output 100 Measures 570 Set Point 25 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDIPOWER AMPEZZO HYDRO POWER PLANT AUTOMATION, CONTROL AND SUPERVISIONE OF AMPEZZO HYDRO POWER PLANT SYSTEM ARCHITECTURE 1 STOP/PC (SCADA, HMI) workstation 4 HMI workstation for local management of generation units, common and auxiliary plant parts 4 DCS acquisition and control nodes (STAR OHF) witch marshalling cabinets in the turbine hall (regulator) and outside (bay units). 1 RTU microSTAR for I/O in valve chamber 1 Remote HMI available through secure internet/intranet connection. MAIN FEATURES Automation, control and protection of power units and common plant parts. Serial connection for MODBUS protocol data acquisition from the APG (Power Units Protection Cabinet) and the ART (Voltage Regulation Cabinet). Connection to remote telecontrol centre via STCE device. I/O DATASET Digital Input672 Digital Output304 Measures168 Set Point 56 71/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDIPOWER S:FILIPPO DEL MELA THERMAL POWER PLANT THERMAL 160 MW POWER PLANT UNITS PROTECTION AND BLOCKING LOGIC ELABORATION SYSTEM (SEB) SYSTEM ARCHITECTURE For each of the 4 power plant units • 1 STOP/PC (SCADA, HMI) workstation • 1 DCS acquisition and control node STAR/D OHF (redundant) connected to STOP/PC via LAN Ethernet TCP/IP For each couple of generation units (1-2 and 3-4): • 1 Engineering workstation WIN/PSCS CONFIG MAIN FEATURES Logic execution over redundant elaboration boards (parallel execution) Alarm emission and acquisition and control of relays status Sequence of Events functionalities. Management of SPDT and SPST signals I/O DATASET Digital Input 1264 72/86 Digital Output 256 Measures 0 Set Point 0 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDIPOWER C.LE TERMOELETTRICA S:FILIPPO DEL MELA PROVISION OF DCS NODES FOR ANALOG MEASURES ACQUISITION SYSTEM ARCHITECTURE Redundant SCADA with master/slave hot backup management , external Watch-dog unit. 3 operator workstations (HMI), one of them used also for system configuration (HMI/CONFIG). 4 redundant DCS nodes (acquisition and control station) STAR OHF connected with SCADA over LAN Ethernet TCP/IP MAIN FEATURES Provision for supervision systems groups 1-2 and 3-4, of additional cabinets for analog input measurement signals with management of RTD signals, replacing the previously installed cabinets Replacing existing network of field-network based on BITBUS with standard Ethernet TCP/IP. Update of diagnostics HMI pages. Supply of OPC server for WIN/SCADA PSCS. I/O DATASET Digital Input 1264 Digital Output 256 Measures 230 Set Point 0 73/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS ENI DIV. E&P GAS COMPRESSION STATION SPILAMBERTO COMMAND AND CONTROL SYSTEM SPILAMBERTO GAS TREATMENT PLANT SYSTEM ARCHITECTURE 2 local HMI workstations (STOP/PC) 1 also used as engineering workstation(CONFIG). Integrated Front End for radio links communications 13 RTU µSTAR 2 remote HMI workstations at Cavone station telecontrol centre DCS redundant data acquisition and control node STAR OHF connected to HMI stations via TCP/IP ethernet LAN. 13 RTU µSTAR located at the gas production wells of the district MAIN FEATURES Control of the central gas production and related wells, providing for their functioning from the remote telecontrol centre. Management of anti-intrusion devices, remote HMI functions. I/O DATASET Digital Input500 74/86 Digital Output100 Measures100 Set Point 16 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA e UAS TSF RETE FERROVIARIA RFI RAILWAY SCADA SYSTEM FOR TRAFFIC MONITORING (CCL/SCT) SYSTEM ARCHITECTURE • Redundant SCADA Servers, with master/slave hot backup management, used for the central control Centers • STOP/PC (SCADA + HMI) with diagnostic and maintenence functionalities • HMI 4 monitor for the whole railway line supervision from the Central Control Centers • STOP/PC (SCADA + HMI) used as peripheral control centers located at the railway stations • Station acquisition unit (UAS) STAR/CSB (96DI) used for train localization functionalities connected to railway station STOP/PC MAIN FEATURES Real time acquisition and processing in, of the train position data, for each monitored railway line. Synoptic representation of the train actual position to the respective line central centers, and to the peripheral stations local centers (Train Describer). Processing and visualization of delays/advances on time, display of line breaks and out of service. Management of the composition of trains, causes of delay and messaging between DM (Movement Managers at the station). 40 central control center stations were installed with synoptic view of the entire line on multi-monitor video wall; 20 stations with engineering functionalities and 693 individual stations, for a total of 753 SCADA / HMI systems. Acquisition devices installed (UAS) are more than 700. I/O DATASET (AVERAGE VALUES FOR EACH RAILWAY LINE) Digital Input 5000 Devices 2200 String1500 Diagnostic 1500 75/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA AEM MILANO RETE GAS MILANO REMOTE CONTROL AND SUPERVISION SYSTEM OF NATURAL GAS DISTRIBUTION PLANTS (CITY OF MILAN) HMI 1 HMI 2 SCADA A HMI 3 / Config SCADA B STAR CSB Ba y N e tw o rks Front End 1 Front End 2 HUB EWDS 32 linee seriali verso apparati Selta e Gavazzi Modem Bank Alle utenze domestiche MODEM GSM, PSTN Impianti di Cassano e Buccinasco SYSTEM ARCHITECTURE SCADA in redundant configuration ( Watch-dog control unit and serial communication device EWDS). On the same PCs there are data storage functions (HDR) and interface functions with STAR/CSB device. 2 HMI stations with dual monitor, connected with SCADA via LAN network. 1 HMI used even for the on-line system configuration (HMI/CONFIG), connected with SCADA via LAN network. 2 on-line printers, for alarm logging and reports printing, and 1 hard copy printer 1 Front-End in redundant configuration, which acquires plants information using 32 peer to peer communication lines connecting more than 150 devices 1 Front-End in redundant configuration, which works: • telephonic lines (PSTN e GSM) toward RTU devices located in Cassano e Buccinasco (protocol IEC870-5-101) • WAN IP connections in order to manage home devices MAIN FEATURES Remote control and supervising of methane gas distribution network in Milano, Buccinasco, Cassano d’Adda and Rosate from different RTU devices produced by third party. System monitors pressure and flow parameters, alarm parameters and state of different plant devices (valves, boilers, …) and communication state; it also provides periodic reports, trends and historical operations. The system controls a total of 62 primary and secondary reduction stations and a total of 690 final reduction stations. I/O DATASET Digital Input 29000 76/86 Digital Output1300 Measures5000 Set Point 0 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT DCS EDISON HYDRO POWER PLANT SONICO AUTOMATION AND CONTROL OF 130 KV POWER STATION SYSTEM ARCHITECTURE 2 control room HMI Stations (STOP/PC) 1 of them used also as engineering workstation (CONFIG). 6 local HMI 5 of which are in the turbine hall (5 turbine units) and 1 for the HV electric substation. Connection to the remote telecontrol center. 7 DCS nodes STAR/OHF ( 5 for the generation units, 1 common plant part, 1 HV substation) connected in Ethernet fiber optic network. MAIN FEATURES Control of the 5 Groups turbine alternator; control sequences for power production management and maintenance tasks. HV/MV substation control, common plant parts management System interfacing with the telecontrol system. (penstock, refrigeration plant, fire, ecc). Design and implementation of level adjustment, hydraulic turbines management according to the measure of the level of the load tank of the plant. I/O DATASET Digital Input1840 Digital Output 576 Measures 344 Set Point 16 77/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA/SIMATIC S7 BERGAMO AMBIENTE SERVIZI BERGAMO WASTE INCINERATOR AUTOMATION, CONTROL, PROTECTION AND INTERBLOCKING FOR POWER GENERATION PLANT FROM WASTE I COMPUTER ROOM STOP PC CONFIG STOP PC STOP PC Documentation Station Maintenance Station ink jet printer ink jet printer Shut-down Panel REDUNDANT PLANT NETWORK Industrial Ethernet 100MB/s DCS-2 System DCS-1 System I/O Locale MCC 1 - 2 Remote I/O - 1A 1 Remote I/O - 1B Remote I/O - 1C Remote I/O - 2A Remote I/O - 2B Remote I/O - 2C 7 Remote I/O - 2D Profibus DP (Optical line) Redundant Serial Link MODBUS RS-485 Profibus DP (Electrical line) PC Industriale PC Industriale Profibus DP (Optical line) Profibus DP (Electrical line) PC Industriale PC Industriale Serial Link ModBus RS232C ESD System A B AS414 FH I/O locale Remote I/O - 5A Pannello Protezioni MCC 3 - 4 - 5 - 6 - 7 1 Remote I/O - 3A Remote I/O - 3B Remote I/O - 3C Remote I/O - 3D Remote I/O - 3E 6 Remote I/O - 4A SYSTEM ARCHITECTURE 2 redundant eXPert SCADA, with I/O connected over Profibus DP, for boiler automation and fumes treatment 1 PLC Siemens SIMATIC S7, fail safe certified, for Emergency Shut Down (ESD) services of the plant. 2 STOP/PC and one STOP/PC CONFIG placed in control room for plant supervision and system configuration. 1 Maintenance Station, used for planned, preventive and corrective maintenance of the whole plant and of the control system. 1 Documentation Station Industrial Ethernet LAN 100MB/s in fiber optic ring configuration. MAIN FEATURES Plant Supervision and control of the incinerator plant and of the power production (10Mw). I/O DATASET Digital Input 1400 78/86 Digital Output 500 Measures 350 Set Point 100 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA / RTAP ENI E&P CASALBORSETTI GAS CONTROL CENTRE OFFSHORE PLATFORMS TELECONTROL LAN TCP/IP SISTEMA DI ANDROMEDONE OS 2 OS 1 OS 3 OS 4 ROUTER CONFIG ROUTER OS 5 MMI MMI MMI MMI LAN ETHERNET TCP/IP SCADA LAN ETHERNET SCADA PRINTER SERVER ROUTER ROUTER PIATTAFORMA GARIBALDI C STAMPANTE EVENTI N. 2 STAMPANTE EVENTI N.1 HARD COPY STAMPANTE TABULATI LINEE SERIALI RS232C F.E. A F.E. B DCS BAILEY INFI 90 Enel 220 Vac 5 AI 5 DI 1 DO I/O PONTE RADIO N. 1 Rete Telecom I/O PONTE RADIO N. 2 modem serviziomodem fonia A D C B MATRICE DI COMMUTAZIONE al sistema di misura fiscale Tartarini linea seriale RS232C - 9600 bauds " Cameretta Primaro Rete Cellulare GSM modem isdn ai vecchi sistemi di telecontrollo D.G. modem modem D A B C MATRICE DI COMMUTAZIONE RTUµSTAR 5 AI 5 DI 1 DO servizio fonia Enel 220 Vac RTUµSTAR Telecamera Cameretta Santerno RTU 1 RTU 2 RTU 16 RTU n RTU 1 PIATTAFORMA N.PANDORA RTU 16 PIATTAFORME GARIBALDI LAYOUT SISTEMA DI TELECONTROLLO CENTRALE DI CASALBORSETTI SYSTEM ARCHITECTURE: Redundant SCADA based on HP 9000-D230 Server (UNIX), master/slave management, hot back-up. 5 local human machine interfaces (HMI), 1 used also as Engineering Workstation (HMI/CONFIG), all based on HP 9000-712 Workstation (OS UNIX). System LAN Ethernet TCP/IP. Remote HMI installed on Garibaldi C offshore platform. 2 on-line printers for alarm logging and reports printing, and 1 hard copy printer. 1 front-end sub-system (redundant), CPU Pentium based microprocessor system, dedicated to data acquisition from off-shore platforms (max. 32) using SDLC communication protocol. Software interface to DCS Bailey, that provides automation and control of Centre plants. The software interface provides data acquisition and visualization to Control Centre operators. MAIN FEATURES: Supervision, remote control and automation of 32 offshore platforms and/or clusters Production historical data management, communication with Andromedone gas dispatching centre. I/O DATASET Digital Input 15000 Digital Output 3500 Measures 3000 Set Point 512 79/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA / RTAP ENI E&P RUBICONE GAS CONTROL CENTRE SCADA SYSTEM FOR GAS TREATMENT PLANT AND RTUs FOR REMOTE CONTROL OF 10 OFFSHORE PLATFORMS OS 1 OS 2 OS 3 LAN TCP/IP SISTEMA DI ANDROMEDONE CONFIG ROUTER MMI FEP OS 4 ROUTER MMI MMI MMI MMI LAN ETHERNET TCP/IP SCADA LAN ETHERNET MMI PRINTER SERVER SCADA ROUTER ROUTER P.MA CERVIA C STAMPANTE TABULATI HARD COPY STAMPANTE EVENTI N. 2 STAMPANTE EVENTI N.1 LAN DUALE BITBUS F.E. A FEP MODBUS DUALE F.E. B STAR 1 I/O PONTE RADIO N. 1 I/O IMPIANTI DI CENTRALE ROUTER SISTEMA DI F&G CENTRALE PONTE RADIO A 2GB sistema misura fiscale Tartarini SISTEMI DI CONTROLLO IMPIANTI FUTURI linea seriale RS232C - 9600 bauds modem servizio modem fonia A D C B MATRICE DI COMMUTAZIONE radio radio RTU ANTONELLA CERVIA A CERVIA B ARIANNA CERVIA C ANEMONE Cl ANEMONE B RTU 16 IMS isdn modem RTU µ STAR P.MA MORENA Rete Telecom Enel 220 Vac RTU µ STAR IMS P.MA CERVIA K DCS ABB Rete Cellulare GSM Cameretta 1 Cameretta 2 RTU µ STAR LAYOUT SISTEMA DI TELECONTROLLO CENTRALE DI RUBICONE SYSTEM ARCHITECTURE Redundant SCADA based on HP 9000-D230 Server (UNIX), master/slave management, hot back-up. 5 local human machine interfaces (HMI), 1 used also as Engineering Workstation (HMI/CONFIG), all based on HP 9000-712 Workstation (OS. UNIX). System LAN Ethernet TCP/IP. Remote HMI installed on Cervia C off-shore platform. 3 on-line printers for alarm logging and reports printing, and 1 hard copy printer. 1 front-end sub-system (redundant), CPU Pentium based microprocessor system, dedicated to data acquisition from off-shore platforms (max. 32) using SDLC communication protocol. MAIN FEATURES Supervision, remote control and automation of 16 offshore platforms and/or clusters (Anemone Cluster, Anemone B, Azalea B, Cervia A, Cervia B, Cervia C, Antonella, Arianna, Morena, Naide). Production historical data management, communication with Andromedone gas dispatching centre. I/O DATASET Digital Input 18000 80/86 Digital Output 3000 Measures 4000 Set Point 512 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT EXPERT SCADA / RTAP ENI E&P FANO GAS CONTROL CENTRE SCADA SYSTEM FOR GAS TREATMENT PLANT AND RTUs FOR REMOTE CONTROL OF 6 OFFSHORE PLATFORMS OS 1 OS 2 OS 3 LAN TCP/IP SISTEMA DI ANDROMEDONE ROUTER CONFIG MMI FEP OS 4 ROUTER MMI MMI MMI MMI LAN ETHERNET TCP/IP SCADA LAN ETHERNET MMI PRINTER SERVER SCADA ROUTER ROUTER P.MA CERVIA C STAMPANTE TABULATI HARD COPY STAMPANTE EVENTI N. 2 STAMPANTE EVENTI N.1 F.E. A GATEWAY F.E. B I/O PONTE RADIO N. 1 DCS MOORE APACS sistema misura fiscale Tartarini linea seriale RS232C - 9600 bauds modem servizio modem fonia A D C B MATRICE DI COMMUTAZIONE RTU BASIL BRENDA DARIA A/B REGINA ANNALISA I/O CENTRALE FANO E COMPRESSORI isdn modem Rete Telecom ANNABELLA Enel 220 Vac RTU 16 RTU µ STAR Rete Cellulare GSM Cameretta 3 Cameretta 1-2 RTU µ STAR LAYOUT SISTEMA DI TELECONTROLLO CENTRALE DI FANO SYSTEM ARCHITECTURE • • • • REDUNDANT SCADA based on HP 9000-D230 Server (UNIX), master/slave management, hot back-up. 5 local human machine interfaces (HMI), 1 used also as Engineering Workstation (HMI/CONFIG), all based on HP 9000-712 Workstation (OS UNIX). System LAN Ethernet TCP/IP. Remote HMI installed on Garibaldi C off-shore platform. 1 on-line printer for alarm logging and reports printing, and 1 hard copy printer. 1 front-end sub-system (redundant), CPU Pentium based microprocessor system, dedicated to data acquisition from off-shore platforms (max. 32) using SDLC communication protocol. MAIN FEATURES Supervision, remote control and automation of 6 offshore platforms and/or clusters (Annabella, Brenda, Basil, Daria A/B, Regina, Annalisa). Production historical data management, communication with Andromedone gas dispatching centre. I/O DATASET Digital Input 19000 Digital Output 3000 Measures 4000 Set Point 1000 81/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT STOP PC AVIO / ENEL MONTALTO DI CASTRO TURBOGAS POWER PLANT 4 SUPERVISION AND CONTROL SYSTEM TURBOGAS UNITS 1/2/3/4 MONTALTO DI CASTRO POWER PLANT ARCHITECTURE (FOR EACH SYSTEM) • • • • 4 local operator workstations (STOP/PC), 2 in control room, 2 in turbine cabin. Connection via redundant BitBus "INET" network to automation and control cabinets of turbogas units. 1 operator workstation is used also as on-line control system engineering worstation (STOP-PC/CONFIG) 2 on-line printers, for journaling and reports, 1 hard copy printer on line MAIN FEATURES Supervision and control of the 4 turbogas power units of the ENEL Montalto di Castro Power Plant, using 4 separate systems. SOE list functionality (with chronological reordering of the signals coming from the different DCS nodes) is also provided. I/O DATASET Digital Input 3200 82/86 Digital Output 500 Measures 600 Set Point 256 eXPert - Main References - Rev. 01 PRODUCT STOP/FE µSTAR CUSTOMER AZIENDA GARDESANA SERVIZI PLANT WASTEWATER COLLECTOR TELECONTROL DISTRIBUTED SYSTEM FOR AUTOMATION, SUPERVISION AND TELECONTROL OF WASTEWATER COLLECTION OF EASTERN GARDA SYSTEM ARCHITECTURE Redundant SCADA with master/slave hot backup management, external watch dog (EWDS) with serial lines switching functionality. • N. 2 HMI stations one of witch with engineering workstation capabilities for the on-line configuration of the whole system (WIN/CONFIG). • N. 1 remote HMI station, based on Notebook, provided to the staff on duty on call. • N. 2 online printers dedicated to the functions of journaling, print outs, hard-copy. • N. 75 RTU Sdi µSTAR for data acquisition and sending commands to remote sites, connected to the central system through the switched telephone network (PSTN and ISDN) and cellular network (GSM). MAIN FEATURES Supervision and telecontrol system of collection sewer Veronese coast of Lake Garda run by the Azienda Gardesana Servizi (AGS). The system consists of a coastline collector of about 60 km that collects waste water from municipalities, through appropriate pumping stations, to the purification plant of Peschiera del Garda. 75 µSTAR RTU placed in special stations along the sewer, exchange digital and analog data and provide automation logic at local and supervisory system.level. The system also has the management function (call) of staff on duty with the possibility of connection to the central system, through appropriate remote HMI. I/O DATASET Digital Input1200 Digital Output600 Measures600 Set Point 150 83/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT WIN/PSCS EDISON PORTO MARGHERA ALARM SYSTEM E RCE OF POWER PLANT PORTO MARGHERA SYSTEM ARCHITECTURE Monitoring and control station WIN/STOP-PC with engineering workstation functionalities for the entire system (WIN/CONFIG). The station is connected via Ethernet with TCP / IP to the automation DCS cabinet (STAR/ OHF). The cabinet consists of the automation multifunction DCS node STAR/OHF, completed with the necessary physical I/O boards. MAIN FEATURES Alarm system and SOE recording system for the thermoelectric power plant EDISON of Porto Marghera Levante. I/O DATASET Digital Input 300 84/86 Digital Output 8 Measures 0 Set Point 0 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT STOP PC AVIO / ENEL CENTRALE TERMINI IMERESEO 2 SUPERVISION AND CONTROL SYSTEM TURBOGAS UNITS 1 AND 2 TERMINI IMERESE POWER PLANT ARCHITECTURE (FOR EACH SYSTEM) • • • • 4 local operator workstations (STOP/PC), 2 in control room, 2 in turbine cabin. Connection via redundant BitBus "INET" network to automation and control cabinets of turbogas units. 1 operator workstation is used also as on-line control system engineering worstation (STOP-PC/CONFIG) 2 on-line printers, for journaling and reports, 1 hard copy printer on line MAIN FEATURES Supervision and control of the 2 turbogas power units of the ENEL Termini Imerese Power Plant, using 2 separate systems. SOE list functionality (with chronological reordering of the signals coming from the different DCS nodes) is also provided. Connection with the remote coordination system of ENEL (SCC). I/O DATASET Digital Input 3200 Digital Output 500 Measures 600 Set Point 256 85/86 eXPert - Main References - Rev. 01 PRODUCT CUSTOMER PLANT STOP FE AEM GAS DISTRICT HEATING TELECONTROL OF CENTRAL HEATING AND DISTRICT HEATING SUBSTATION SYSTEM ARCHITECTURE • • • • • • Redundant SCADA with master/slave hot backup management, external watch-dog unit with serial lines switching Front End functionalities (switched lines management, patrols, communication protocols implementation) integrated in SCADA stations. 2 local HMI availables on the same units used for SCADA functions, 1 of wich used also as on-line engineering workstation (MMI/CONFIG). 1 remote HMI station due modem per la gestione della comunicazione fra il sistema centrale e le apparecchiature NITEL 2 on-line printersfor journaling and reports, 1 hard copy printer. MAIN FEATURES Management of 7 Heating Plants and 350 district heating substations. Treatment of acquired measures, and implementation of remote settings or set-point setting of instrumentation and / or local equipment connected to the center by the teleoperation peripheral devices (NITEL). Creating and viewing of "schedules" on daily and weekly basis. Graphical representation of the curve of heating and cooling with ability to view and change the settings of the curve. I/O DATASET Digital Input 1000 86/86 Digital Output 150 Measures 2200 Set Point 400