Gru a bandiera a colonna PIASTRE DI BASE PER FISSAGGIO MEDIANTE TASSELLI CHIMICI Column - mounted jib cranes BASE PLATES FOR MOUNTING WITH CHEMICAL BOLTS CARATTERISTICHE SPECIFICATION The table shows the drawings of the base plates to be fixed to the floor with chemical anchor bolts. For the stability of the jib crane, each bolt will be subject to a tensile strength of ~ 31.25 kN. For the reliability of the anchoring system it is still essential that the floor where the crane is anchored meets the features listed below (in addition to the loads arising from the operation of the crane itself, which can be calculated from the table above): - Concrete strength not less than C25 (i.e. 25 N/mm2); - Floor minimum thickness 180 mm; - Floor equipped with adequate metal reinforcement to withstand the aforementioned strength around the bolts. The suitability for floor mounting can be ensured by the designer of the building or otherwise a proper survey of the floor area where the crane will be installed should be performed by a designated person. For each bolt, it is necessary to make a Ø18 mm hole with a depth of 125 mm on the floor. Each bolt must then be fastened using a torque wrench with a tightening torque of 100 Nxm. Tipo/Type C2/Q La tabella rappresenta i disegni delle piastre di base il cui fissaggio a pavimento è previsto con bulloni ad ancoraggio chimico. Per la stabilità della bandiera, ciascun bullone sarà soggetto ad una trazione di ~31.25 kN. Per la sicura affidabilità del sistema di ancoraggio è indispensabile che il pavimento su cui si ancora la gru soddisfi alle sotto indicate caratteristiche (oltre ovviamente ai carichi derivanti dall’esercizio della gru stessa, e deducibili dalla tabella soprastante): - Resistenza del calcestruzzo non inferiore a C25 (ovvero 25 N/mm2); - Spessore minimo pavimento 180 mm; - Pavimento provvisto di adeguata armatura metallica per resistere, nell’intorno dei bulloni, alla trazione suindicata. L’idoneità del pavimento, per tale ancoraggio, potrà essere assicurata dal progettista del capannone o diversamente dovrà essere eseguito a cura di un incaricato, un adeguato sondaggio nella zona di pavimento dove la gru verrà installata. Per ogni tassello si dovrà eseguire sul pavimento un foro di Ø18 mm e di profondità 125 mm. Ogni tassello dovrà poi essere fissato con chiave dinamometrica alla coppia di serraggio di 100 Nxm. Tipo/Type C2A - C3A Tipo/Type C3C - C4A - C4B - C5A - C6A 172 Rev. 05/2014 Tipo/Type C2B/1 - C2B/2 Tipo/Type C7A - C7A/2 Gru a bandiera a colonna PIASTRE DI BASE PER FISSAGGIO MEDIANTE TASSELLI CHIMICI Column - mounted jib cranes BASE PLATES FOR MOUNTING WITH CHEMICAL BOLTS DATI TECNICI TECHNICAL DATA Momento max alla base Carico verticale su base mm Mf (kNxm) N (kN) 320 11.9 5.6 400 320 11.9 5.6 125 400 320 11.9 5.6 19 125 500 420 18 6.4 8 19 125 500 420 18 6.4 M16 8 19 125 600 520 25 10 16 M16 16 19 125 720 640 43 16 400x400 8 M16 8 19 125 400 320 11.9 5.6 C2/Q 400x400 8 M16 8 19 125 400 320 11.9 5.6 C2A 500x500 8 M16 8 19 125 500 420 18 6.4 G 25/5 C3A 600x600 8 M16 8 19 125 600 520 25 10 G 25/6 C4A 720x720 16 M16 16 19 125 720 640 43 16 G 25/7 C4A 720x720 16 M16 16 19 125 720 640 43 16 G 25/8 C4B 720x720 16 M16 16 19 125 720 640 452 13 G 50/2 C2B/1 500x500 8 M16 12 19 125 500 420 20 6.6 G 50/3 C2B/2 500x500 12 M16 12 19 125 500 420 23 9 G 50/4 C4A 720x720 16 M16 16 19 125 720 640 43 16 G 50/5 C4A 720x720 16 M16 16 19 125 720 640 43 16 G 50/6 C5A 800x800 16 M16 16 19 125 800 720 56 12.5 Tasselli Base dimensions Bolts Fori profondità A I mm n. 400x400 8 M16 Ø mm mm mm 19 125 400 400x400 8 8 19 125 C2/Q 400x400 M16 8 19 G 12/5 C2A 8 M16 8 G 12/6 500x500 8 M16 C3A 600x600 8 G 12/8 C4A 720x720 G 25/2 C2/Q G 25/3 G 25/4 Piastra tipo Base plate type G 12/2 C2/Q G 12/3 C2/Q G 12/4 Tasselli dimensione Fori Fori Holes Holes n. 8 M16 8 500x500 C2A G 12/7 Bolts dimensions Holes depth Maximum reaction at the base Vertical load on the base G 50/7 C6A 900x900 16 M16 16 19 125 900 800 62 17 G 100/2 C3C 600x600 16 M16 16 19 125 600 520 32 15 G 100/3 C4A 720x720 16 M16 16 19 125 720 640 43 16 G 100/4 C6A 900x900 16 M16 16 19 125 900 800 62 17 G 100/5 C7A-2 1000x1000 20 M16 20 19 125 1000 700 82 19 G 100/6 C7A 1000x1000 20 M16 20 19 125 1000 700 100 22 GRU A BANDIERA JIB CRANES Piastra dimensioni Gru tipo Crane type •G = Piastra valida per tutti i tipi di gru (C - CT - C2T). •G = Base plate suitable for all types of cranes (C-CT-C2T). Rev. 05/2014 173