VA air condensed water chillers with axial fans, semi hermetic screw compressors, R134a refrigerant gas; Cooling capacity 222 to 948 kW VA STANDARD VERSION LOW ENERGY VERSION SUPER SILENT VERSION VERSION WITH 1 OR 2 COOLING CIRCUITS • CLIENT VA TAILORED TO CUSTOMERS NEEDS • • • • Refrigerant R134a Specifications: • Structure in electro-zinc plated and painted sheet steel • R134a Refrigerant • One or two semi-hermetic dual screw compressors • High efficiency finned coil condensers featuring narrow copper pipes lined on the inside for minimizing refrigerant load • Evaporators with broad pipes devised especially for R134a gas • Silent high efficiency axial fans with speed control device • Standard thermostatic expansion valves • Electronic expansion valves on request for all machine models • Guaranteed operation of the chiller with air as cold as 47°C1 1 According to version • Electronic microprocessor control unit for monitoring and configuring all machine data: water return temperature control, optional adjustment of water supply step control of the cooling capacity safety step control for high pressure condenser fan speed control(motor evaporator version) silent mode circulation pump control second circulation pump control pump rotation burst function (pump stars only when necessary) flow-switch water temperature setpoint that can be adjusted according to the outside temperature or outside contact communication with monitoring systems. Controlled device alarms Anti-freeze alarm Versions and accessories on request: • • • • • • • • • • • N ........ Normal E ........ High energy efficiency R ........ Partial Recovery R1........ Full Recovery F ......... Freecooling INV...... Compressor with integrated inverter (only for certain models) CLIENT VA water chillers and heat pumps tailored to customers needs EEV ..... Electronic Expansion Valve/s P0 Without hydronic kit P1 Hydronic kit comprising a circulation pump, a safety valve and water filter P2 Hydronic kit comprising a double circulation pump, a safety valve and water filter • P3 Hydronic kit comprising a high pressure circulation pump, a safety valve and water filter • P4 Hydronic kit comprising a double high pressure circulation pump, a safety valve and water filter • RS485 RS 485 serial card • RS232 RS 232 serial card for modem • LON .... LON FTT10 STD serial card • WEB ... Card for local area network (LAN) or Internet • CK ....... Clock card • RIF...... Power factor correction system • ST ....... Device for decreasing the breakaway starting current • AV ....... Anti-vibration supports • PR ...... Remote control panel Rigel Impianti - Zona Industriale Padule 06020, Gubbio (Pg) - Numero Verde 800 503 980 - Tel. +39 075 929 11 13 +39 075 929 10 63 - Fax +39 075 929 92 94 Technical sheets VA-N MODEL VA-N SIZE 251 281 321 361 401 461 302 332 372 422 482 542 622 712 812 Cooling capacity 222,0 250,0 288,0 335,0 379,0 428,0 264,0 300,0 338,0 384,0 444,0 500,0 576,0 670,0 790,0 (kW) 922 1032 856,0 948,0 Total power requirement (kW) 83,5 93,1 105,7 124,4 140,9 160,5 108,6 123,7 137,8 148,4 170,2 186,9 213,5 250,3 291,6 318,0 350,5 Water capacity (m3/h) 38,2 43,0 49,5 57,6 65,2 73,6 45,4 51,6 58,1 66,0 76,4 86,0 99,1 115,2 135,9 147,2 163,1 44 47 51 43 46 49 48 52 57 63 73 54 45 48 53 45 47 43,5 43,5 43,0 43,0 43,5 43,5 43,5 43,0 43,0 43,0 44,0 44,5 44,0 42,7 42,3 43,5 43,5 2,66 3,45 2,68 3,48 2,72 3,53 2,69 3,49 2,69 3,49 2,67 3,45 2,43 3,49 2,42 3,48 2,45 3,52 2,59 3,71 2,61 3,74 2,67 3,84 2,70 3,87 2,68 3,84 2,71 3,89 2,69 3,86 2,70 3,88 58000 72000 75600 84000 111000 140000 74000 111000 111000 111000 1 1 1 1 1 1 2 2 2 2 Pressure loss for hydronic circuit (kPa) Max operating temperature of outside air (°C) EER (kW/kW) ESEER (kW/kW) Total air capacity (m3/h) Number of compressors (n.) Number of circuits (n.) Operating current RLA (A) Max current (FLA) (A) Breakway starting current (RLA) (A) Sound pressure 10m (dB(A)) Victaulic Hydraulic fittings(DN mm) Tank capacity (litres) 140000 148000 177500 182500 213000 249200 280000 2 2 2 2 2 2 2 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 132 146 166 196 220 248 86 96 107 116 132 146 166 196 228 248 273 184 204 232 275 308 348 120 134 150 162 184 204 232 275 320 348 382 921 1019 1162 1375 1539 1738 600 669 750 810 921 1019 1162 1375 1599 1738 1912 60,9 61,7 62,1 62,4 63,2 63,8 62,5 63,2 63,6 64,1 64,7 65,1 65,7 66,1 66,6 67,2 67,7 80 80 80 100 100 100 80 80 80 80 80 100 125 125 125 150 150 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 2,7 3,0 3,4 4,0 4,5 5,1 3,2 3,6 4,0 4,6 5,3 6,0 6,9 8,0 9,4 10,2 11,3 5,5 6,2 7,1 8,3 9,3 10,6 6,5 7,4 8,3 9,5 10,9 12,3 14,2 16,5 19,5 21,1 23,4 4,6 5,2 6,0 6,9 7,8 8,9 5,5 6,2 7,0 8,0 9,2 10,4 11,9 13,9 16,4 17,7 19,6 9,5 10,7 12,3 14,3 16,2 18,3 11,3 12,8 14,4 16,4 19,0 21,4 24,6 28,6 33,8 36,6 40,5 Useful pressure of the hydronic KIT with low pressure pump (kPa) 110 106 100 104 96 104 99 91 82 67 70 84 90 81 70 115 109 Useful pressure of the hydronic KIT with high pressure pump (kPa) 210 206 200 204 196 204 199 191 182 167 170 184 190 181 170 215 209 302 332 VA-N 372 Max operating pressure(bar) Power requirement of low pressure pump (kW) Current requirement of low pressure pump (A) Power requirement of high pressure pump (kW) Current requirement of high pressure pump (A) DIMENSIONS SIZE Lenght (mm) Witdh (mm) Height (mm) Total weight at no load (excluding any hydronic kits and inertia tank) (kg) 251 281 321 361 401 461 422 482 542 622 712 812 922 1032 3950 2195 2420 3950 2195 2420 3950 2195 2420 5100 2195 2420 5100 2195 2420 5100 2195 2420 4550 2195 2420 5700 2195 2420 5700 2195 2420 5700 2195 2420 5700 2195 2420 7450 2195 2420 7450 2195 2420 8600 2195 2420 8600 2195 2420 7950 2195 2420 9700 2195 2420 2895 3239 3698 4254 4762 5314 3410 3842 4289 4819 5491 6098 6892 7825 8938 9513 10428 Performance in the following conditions: Cooling: water (in/out) 12/7°C; air 35°C Heating: water (in/out) 40/45°C; air 7°C b.s./UR 87% Voltage supply 400V - 50Hz Sound pressure in free field on reflecting surface (directivity index 2) as per ISO 3744 Rigel Impianti - Zona Industriale Padule 06020, Gubbio (Pg) - Numero Verde 800 503 980 - Tel. +39 075 929 11 13 +39 075 929 10 63 - Fax +39 075 929 92 94 Technical sheets MODEL SIZE 251 Cooling capacity (kW) 221,0 Total power requirement (kW) 72,6 Water capacity (m3/h) 38,0 Pressure loss for hydronic circuit 44 (kPa) Max operating temperature of 47,5 outside air (°C) EER (kW/kW) 3,12 ESEER (kW/kW) 4,04 Total air capacity (m3/h) 75400 Number of compressors (n.) 1 Number of circuits (n.) 1 Operating current RLA (A) 111 Max current (FLA) (A) 155 Breakway starting current (RLA) 774 (A) Sound pressure 10m (dB(A)) 61,2 Victaulic Hydraulic fittings(DN 80 mm) Tank capacity (litres) NP Max operating pressure(bar) 6,0 Power requirement of low 2,6 pressure pump (kW) Current requirement of low 5,4 pressure pump (A) Power requirement of high 4,6 pressure pump (kW) Current requirement of high 9,4 pressure pump (A) Useful pressure of the hydronic 109 KIT with low pressure pump (kPa) Useful pressure of the hydronic KIT with high pressure pump 209 (kPa) DIMENSIONS SIZE Lenght (mm) Witdh (mm) Height (mm) Total weight at no load 251 3950 2195 2420 2883 281 250,0 VA-E 321 281,0 361 325,0 401 378,0 461 428,0 VA-E 372 422 316,0 362,0 482 442,0 542 500,0 622 562,0 712 650,0 812 756,0 922 856,0 83,3 91,5 103,4 123,6 138,7 104,8 118,7 145,6 161,2 179,8 208,4 247,6 283,1 43,0 48,3 55,9 65,0 73,6 54,4 62,3 76,0 86,0 96,7 111,8 130,0 147,2 47 48 41 45 49 50 56 72 54 42 45 49 45 49,0 48,0 47,0 47,5 46,0 47,0 46,0 46,0 45,0 46,0 46,5 46,0 46,0 3,00 3,07 3,16 3,07 3,11 2,99 3,02 3,01 3,10 3,14 3,15 3,11 3,11 3,89 3,98 4,09 4,41 4,46 4,29 4,34 4,31 4,44 4,51 4,52 4,46 4,03 105000 108000 108000 140000 140000 105000 113400 140000 148000 175000 216000 245000 280000 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 124 137 157 185 210 81 92 112 124 137 157 185 210 173 192 219 259 294 113 128 157 173 192 219 259 294 867 958 1096 1296 1468 565 641 783 867 958 1096 1296 1468 61,9 62,3 62,8 63,4 63,8 61,5 61,9 62,6 63,0 63,6 64,2 58,5 63,8 80 80 100 100 100 80 80 80 100 125 125 125 150 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 NP 6,0 3,0 3,4 3,9 4,5 5,1 3,8 4,3 5,3 6,0 6,7 7,8 9,0 10,2 6,2 6,9 8,0 9,3 10,6 7,8 8,9 10,9 12,3 13,9 16,0 18,6 21,1 5,2 5,8 6,7 7,8 8,9 6,5 7,5 9,2 10,4 11,6 13,5 15,7 17,7 10,7 12,0 13,9 16,2 18,3 13,5 15,5 18,9 21,4 24,0 27,8 32,3 36,6 105 100 114 107 102 99 88 67 80 81 115 111 111 205 200 214 207 202 199 188 167 180 181 215 211 211 281 3950 2195 2420 3239 321 5100 2195 2420 3615 361 5100 2195 2420 4137 401 5100 2195 2420 4751 461 5700 2195 2420 5314 482 7450 2195 2420 5469 542 7450 2195 2420 6098 622 6800 2195 2420 6748 712 7950 2195 2420 7631 812 8550 2195 2420 8632 922 9700 2195 2420 9513 VA-E 372 422 5700 5700 2195 2195 2420 2420 4031 4567 Performance in the following conditions: Cooling: water (in/out) 12/7°C; air 35°C Heating: water (in/out) 40/45°C; air 7°C b.s./UR 87% Voltage supply 400V - 50Hz Sound pressure in free field on reflecting surface (directivity index 2) as per ISO 3744 Rigel Impianti - Zona Industriale Padule 06020, Gubbio (Pg) - Numero Verde 800 503 980 - Tel. +39 075 929 11 13 +39 075 929 10 63 - Fax +39 075 929 92 94 Technical sheets VA-S MODEL VA-S SIZE 251 281 321 361 401 461 302 332 372 422 482 542 622 712 812 Cooling capacity 212,0 238,0 275,0 320,0 365,0 409,0 250,0 284,0 320,0 364,0 424,0 476,0 550,0 640,0 724,0 (kW) 922 1032 818,0 906,0 Total power requirement (kW) 87,6 99,0 111,0 130,9 149,1 168,6 113,0 128,1 143,4 154,2 178,2 196,2 226,4 266,5 300,3 342,2 380,5 Water capacity (m3/h) 36,5 40,9 47,3 55,0 62,8 70,3 43,0 48,8 55,0 62,6 72,9 81,9 94,6 110,1 124,5 140,7 155,8 41 43 46 40 42 44 43 47 51 57 66 49 41 44 45 41 43 43,5 43,5 43,0 43,0 43,5 43,5 43,5 43,0 43,0 43,0 44,0 44,5 44,0 42,7 42,3 43,5 43,5 2,40 3,11 2,39 3,09 2,46 3,19 2,43 3,15 2,44 3,50 2,42 3,47 2,20 3,15 2,20 3,16 2,22 3,18 2,34 3,36 2,36 3,39 2,42 3,48 2,44 3,50 2,42 3,47 2,44 3,50 2,44 3,16 2,44 3,17 52200 64800 68040 75600 99900 126000 66600 99900 99900 99900 164250 191700 224280 252000 1 1 1 1 1 1 2 2 2 2 2 2 2 2 Pressure loss for hydronic circuit (kPa) Max operating temperature of outside air (°C) EER (kW/kW) ESEER (kW/kW) Total air capacity (m3/h) Number of compressors (n.) Number of circuits (n.) Operating current RLA (A) Max current (FLA) (A) Breakway starting current (RLA) (A) Sound pressure 10m (dB(A)) Victaulic Hydraulic fittings(DN mm) Tank capacity (litres) 126000 133200 159750 2 2 2 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 141 158 178 210 237 265 91 101 114 123 141 155 178 210 235 265 293 197 221 249 294 332 372 127 141 159 172 197 217 249 294 329 372 410 986 1106 1244 1470 1658 1858 636 707 797 859 986 1085 1244 1470 1644 1858 2050 55,3 55,6 55,8 57,0 57,2 58,2 54,2 55,1 55,4 55,8 56,5 56,8 57,5 57,8 58,4 59,0 59,5 80 80 80 100 100 100 80 80 80 80 80 100 125 125 125 150 150 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 2,5 2,8 3,3 3,8 4,4 4,9 3,0 3,4 3,8 4,3 5,1 5,7 6,6 7,6 8,6 9,8 10,8 5,2 5,9 6,8 7,9 9,0 10,1 6,2 7,0 7,9 9,0 10,5 11,7 13,6 15,8 17,9 20,2 22,3 4,4 4,9 5,7 6,6 7,6 8,5 5,2 5,9 6,6 7,5 8,8 9,9 11,4 13,3 15,0 16,9 18,8 9,1 10,2 11,8 13,7 15,6 17,5 10,7 12,1 13,7 15,6 18,1 20,3 23,5 27,4 30,9 35,0 38,7 Useful pressure of the hydronic KIT with low pressure pump (kPa) 113 109 102 104 111 107 102 94 82 87 73 89 91 83 115 115 112 Useful pressure of the hydronic KIT with high pressure pump (kPa) 213 209 202 204 211 207 202 194 182 187 173 189 191 183 215 215 212 Max operating pressure(bar) Power requirement of low pressure pump (kW) Current requirement of low pressure pump (A) Power requirement of high pressure pump (kW) Current requirement of high pressure pump (A) DIMENSIONS SIZE Lenght (mm) Witdh (mm) Height (mm) Total weight at no load 251 3950 2195 2420 2771 281 3950 2195 2420 3093 321 3950 2195 2420 3542 361 5100 2195 2420 4078 401 5100 2195 2420 4602 461 5100 2195 2420 5102 302 4550 2195 2420 3239 332 5700 2195 2420 3651 VA-S 372 5700 2195 2420 4078 422 5700 2195 2420 4590 482 5700 2195 2420 5269 542 7450 2195 2420 5840 622 7450 2195 2420 6624 712 8600 2195 2420 7533 812 8600 2195 2420 8337 Performance in the following conditions: Cooling: water (in/out) 12/7°C; air 35°C Heating: water (in/out) 40/45°C; air 7°C b.s./UR 87% Voltage supply 400V - 50Hz Sound pressure in free field on reflecting surface (directivity index 2) as per ISO 3744 Rigel Impianti - Zona Industriale Padule 06020, Gubbio (Pg) - Numero Verde 800 503 980 - Tel. +39 075 929 11 13 +39 075 929 10 63 - Fax +39 075 929 92 94 922 7950 2195 2420 9185 1032 9700 2195 2420 9966 Technical sheets VA-E-S MODEL SIZE 251 281 321 361 401 Cooling capacity (kW) 212,0 242,0 273,0 314,0 366,0 VA-E-S 461 372 422 482 542 622 414,0 306,0 350,0 424,0 484,0 546,0 712 628,0 812 732,0 922 828,0 Total power requirement (kW) 74,4 85,7 94,3 106,4 127,2 141,5 109,3 126,5 148,9 168,1 187,6 216,3 257,0 290,8 Water capacity (m3/h) 36,5 41,6 47,0 54,0 63,0 71,2 52,6 60,2 72,9 83,2 93,9 108,0 125,9 142,4 41 44 46 38 43 45 47 53 66 50 40 42 45 42 47,5 49,0 48,0 47,0 47,5 46,0 47,0 46,0 46,0 45,0 46,0 46,5 46,0 46,0 2,83 3,66 2,80 3,62 2,87 4,12 2,93 4,21 2,86 4,11 2,92 4,18 2,78 3,99 2,75 3,94 2,82 4,05 2,88 4,13 2,92 4,20 2,93 4,21 2,89 3,75 2,92 3,78 67860 94500 97200 97200 1 1 116 162 811 1 1 131 183 917 1 1 145 203 1015 1 1 165 231 1157 1 1 196 274 1370 1 1 219 307 1535 2 1 85 119 597 2 1 99 139 694 2 1 116 162 811 2 1 131 183 917 2 1 145 203 1015 2 1 165 231 1157 2 1 196 274 1370 2 1 219 307 1535 Sound pressure 10m (dB(A)) 53,1 54,1 54,4 54,7 55,5 55,8 53,7 54,1 54,8 55,1 55,8 56,5 53,5 56,6 Victaulic Hydraulic fittings(DN mm) Tank capacity (litres) 80 NP 80 NP 80 NP 100 NP 100 NP 100 NP 80 NP 80 NP 80 NP 100 NP 125 NP 125 NP 125 NP 150 NP Max operating pressure(bar) 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 Power requirement of low pressure pump (kW) 2,5 2,9 3,3 3,8 4,4 4,9 3,7 4,2 5,1 5,8 6,5 7,5 8,7 9,9 Current requirement of low pressure pump (A) 5,2 6,0 6,7 7,7 9,0 10,2 7,5 8,6 10,5 11,9 13,5 15,5 18,0 20,4 Power requirement of high pressure pump (kW) 4,4 5,0 5,7 6,5 7,6 8,6 6,3 7,2 8,8 10,0 11,3 13,0 15,2 17,1 Current requirement of high pressure pump (A) 9,1 10,3 11,7 13,4 15,6 17,7 13,1 15,0 18,1 20,7 23,3 26,8 31,3 35,4 Useful pressure of the hydronic KIT with low pressure pump (kPa) 112 106 100 115 109 104 99 88 69 77 120 118 110 112 Useful pressure of the hydronic KIT with high pressure pump (kPa) 212 206 200 215 209 204 199 188 169 177 220 218 210 212 251 3950 2195 2420 2771 281 3950 2195 2420 3142 321 5100 2195 2420 3518 361 5100 2195 2420 4007 401 5100 2195 2420 4613 461 5700 2195 2420 5158 482 7450 2195 2420 5269 542 7450 2195 2420 5927 622 6800 2195 2420 6583 712 7950 2195 2420 7415 812 8550 2195 2420 8411 922 9700 2195 2420 9272 Pressure loss for hydronic circuit (kPa) Max operating temperature of outside air (°C) EER (kW/kW) ESEER (kW/kW) Total air capacity (m3/h) Number of compressors (n.) Number of circuits (n.) Operating current RLA (A) Max current (FLA) (A) Breakway starting current (RLA) (A) DIMENSIONS SIZE Lenght (mm) Witdh (mm) Height (mm) Total weight at no load 126000 126000 94500 102060 126000 133200 157500 194400 220500 VA-E-S 372 422 5700 5700 2195 2195 2420 2420 3913 4429 Performance in the following conditions: Cooling: water (in/out) 12/7°C; air 35°C Heating: water (in/out) 40/45°C; air 7°C b.s./UR 87% Voltage supply 400V - 50Hz Sound pressure in free field on reflecting surface (directivity index 2) as per ISO 3744 We are constantly improving upon our products so the technical data may be modified without forewarning. Rigel Impianti - Zona Industriale Padule 06020, Gubbio (Pg) - Numero Verde 800 503 980 - Tel. +39 075 929 11 13 +39 075 929 10 63 - Fax +39 075 929 92 94 252000