HDRB | LRB HIGH DAMPING RUBBER BEARINGS LEAD RUBBER BEARINGS Foto in copertina: il polo direzionale De Cecco a Pescara, isolato con HDRB (Italia, 2008) Cover: De Cecco Group’s new office building in Pescara, isolated with HDRB (Italy, 2008) Protezione sismica delle strutture Caratteristiche generali Materiali Modellazione matematica HDRB Modellazione matematica LRB Tabelle prestazionali HDRB Tabelle prestazionali LRB Prove di laboratorio Resistenza al fuoco Manutenzione Normativa di riferimento Posa in opera 4 6 8 10 11 12 18 21 21 21 21 22 Seismic protection of structures General features Materials Mathematical Modeling of HDRB Isolators Mathematical Modeling of LRB Isolators Performance Tables HDRB Performance Tables LRB Laboratory Tests Fire resistence Maintenance Reference Norms Installation 5 7 8 10 11 12 18 21 21 21 21 22 Il ponte sopra il fiume Tago a Santarem, isolato con HDRB (Portogallo, 2000) The Tagus bridge at Santarem, isolated with HDRB (Portugal, 2000) Protezione sismica delle strutture calcolo dell’intera struttura. La scelta del dispositivo è da farsi in modo accurato in relazione al problema specifico in modo da ottimizzare le funzioni e i vantaggi descritti. La protezione sismica delle strutture rappresenta uno dei più interessanti obbiettivi degli ingegneri strutturali allo scopo di minimizzare i danni alle costruzioni e di salvare vite umane in caso di terremoti di elevata intensità. La funzione principale degli isolatori sismici è quella di abbattere l’azione sismica riducendo le forze orizzontali che sollecitano la struttura in caso di terremoto. Questo è possibile grazie a due effetti combinati: • Aumentando la flessibilità tramite l’inserimento di isolatori sismici fra le fondazioni e la sovrastruttura, si aumenta notevolmente il periodo proprio, riducendo così l’accelerazione spettrale e quindi le forze sismiche; • dissipando energia (sotto forma di calore) l’isolatore permette un abbattimento dello spettro di risposta che si traduce in un’ ulteriore riduzione delle forze sismiche Aumento del periodo Increasing period Questi effetti portano a due ulteriori enormi vantaggi dell’utilizzo dell’isolamento sismico Aumento dello smorzamento Increasing damping 1. La riduzione delle azioni sismiche nella struttura ha come immediato vantaggio la riduzione del costo della struttura stessa. Maggiore è la sismicità della zona, maggiore sarà il risparmio. Quindi l’isolamento sismico conviene anche da un punto di vista economico. 2. Secondo la normativa europea, se in una struttura isolata lo smorzamento equivalente è inferiore al 30%, la struttura può essere calcolata come lineare equivalente (di seguito viene spiegata in dettaglio la procedura di calcolo), semplificando enormemente la modellazione e il 4 Il centro polifunzionale di Soccavo a Napoli adeguato sismicamente con oltre 600 HDRB (Italia, 2006) The multipurpose building of Soccavo in Naples retrofitted by the use of more then 600 HDRB (Italy, 2006) • dissipating energy (in the form of heat) the isolator allows a reduction of the response spectrum that results in a further reduction of seismic forces. I principali vantaggi delle due tipologie di isolatori sismici descritte in questo catalogo sono: HDRB • Maggiori capacità di ricentraggio della struttura in seguito a un sisma. • Minore rigidezza che permette di avere un periodo proprio della struttura isolata maggiore. 1. The reduction of seismic actions in the structure has the immediate advantage of reducing the cost of the structure. The greater is the seismicity of the area, the grater is the saving. Therefore the seismic isolation is also advantageous from an economic point of view. 2. According to the European standards, if the equivalent viscous damping of an isolated structure is less than 30%, it may be calculated as linear equivalent (below is explained in detail the calculation procedure), greatly simplifying the modelling and design of the entire structure. LRB • Maggiore rigidezza iniziale. Grazie al nucleo in piombo posto al suo interno i dispositivi tipo LRB hanno un comportamento rigido-plastico. Danno quindi spostamenti trascurabili per carichi non elevati come ad esempio vento o frenatura • Maggiore capacità di smorzamento (anche oltre il 30%) The choice of the device is to be made accurately in relation to the specific problem in order to optimize the described features and benefits. Seismic protection of structures Seismic protection of structures is one of the most interesting targets for structural engineers in order to minimize property damage and save lives in case of earthquakes of high intensity. The main function of the seismic isolators is to reduce the seismic action by reducing the horizontal forces which solicitate buildings in case of earthquake. This is possible thanks to two combined effects: The main advantages of the two types of seismic isolators described in this catalogue are: HDRB • More recentring capacity after an earthquake. • Lower stiffness to get a higher natural period. LRB • Higher initial stiffness. Thanks to the lead core these devices have a rigid-plastic behaviour. They therefore allow very small movement due to loads such as wind or braking. • Higher values of damping (even grater than 30%). • Increasing the lateral flexibility by the use of seismic isolators between the foundation and the superstructure, the natural period is greatly increased, reducing the spectral acceleration and hence the seismic forces; 5 Aeroporto di Antalya adeguato sismicamente con l’utilizzo di LRB (Turchia, 2003) Antalya Airport retrofitted by the use of LRB isolators (Turkey, 2003) Caratteristiche generali General features Gli isolatori in gomma ad alta dissipazione di energia (High Damping Rubber Bearings, HDRB) sono stati sviluppati nel 1985 in California dal prof. Jim Kelly dell’Università di Berkeley. ALGA è stata la prima ad applicare in Europa questa tecnologia nel 1987 per l’edificio Telecom di Ancona, progettato dall’Ing. Giancarlo Giuliani, avvalendosi della consulenza dello stesso prof. Kelly. Gli isolatori in gomma – piombo (Lead Rubber Bearings LRB) sono stati sviluppati per la prima volta in Nuova Zelanda nel 1974 ma sono stati introdotti in Europa successivamente agli HDRB High Damping Rubber Bearings (HDRB) were developed in 1985 by Professor Jim Kelly at the University of California at Berkeley. ALGA was the first Company whitch applied this technology in Europe, using it in 1987 for the Telecom building in Ancona. The building was designed by engineer Giancarlo Giuliani with consultation by Professor Kelly himself. Lead Rubber Bearings (LRB) were first developed in New Zeeland, in 1974, but these were introduced in Europe only after the HDRB technology. ALGASISM HDRB Gli HDRB sono costituiti da una serie di strati di gomma vulcanizzati a lamiere in acciaio, in modo da ottenere un dispositivo in grado di sopportare elevati carichi verticali con minima compressione (elevata rigidezza verticale) e di consentire elevati spostamenti orizzontali con reazioni relativamente piccole (bassa rigidezza orizzontale). Caratteristica fondamentale della gomma è quella di dissipare energia. Posti al disotto di un edificio o di un impalcato da ponte hanno l’effetto di aumentare il periodo proprio della struttura dissipando energia, riducendo così grandemente gli effetti di un’azione sismica. Gli HDRB sono imbullonati a piastre metalliche esterne che consentono il fissaggio alle strutture adiacenti mediante zanche o bulloni. ALGASISM High Damping Rubber Bearings (HDRB) The HDRB isolators are constituted of a series of vulcanized rubber layers separated by reinforcing steel plates, thus providing a device capable of supporting high vertical loads with minimal compression (elevated vertical stiffness) and allowing high horizontal displacements with relatively small reactions (low horizontal stiffness). The main property of the rubber is its ability to dissipate energy (damping capacity). When positioned underneath a building or underneath bridge beams, they have the effect of increasing the structure’s fundamental vibration period, thus greatly reducing any effects of seismic activity. The HDRB isolators are bolted to external metal plates allowing them to be fixed to the adjacent structures using anchor brackets or bolts. ALGASISM LRB Sono simili agli ALGASISM HDRB descritti nel paragrafo precedente con la differenza che la dissipazione di energia è ottenuta anche attraverso uno o più nuclei di piombo inseriti al loro interno. Il piombo (viene impiegato piombo puro al 99,9%) ha la proprietà di deformarsi plasticamente dissipando energia e ricristallizzando dopo un ciclo di deformazione plastica. In tal modo esso può sopportare un numero indefinito di cicli di isteresi. ALGASISM Lead Rubber Bearings (LRB) These isolators are similar to the previous but with the exception that the dissipation of energy is obtained also through the use of one or more lead cores. Lead (used here at a level of 99.9% purity) has the property of undergoing plastic deformation as it dissipates energy and then re-crystallizing after a cycle of plastic deformation. Because of this, it is able to sustain an unlimited number of hysteresis loops. 6 Il Viadotto Sakarya isolato con LRB da 1400 mm di diametro, i più grandi mai realizzati. (Turchia, 2009) The Sakarya Viaduct, seismic isolated by the use of the biggest LRB ever produced, diameter 1400mm (Turkey, 2009) Materiali Materials ALGA ha sviluppato diversi tipi di mescola per potersi meglio adattare alle esigenze progettuali. Per gli HDRB sono disponibili tre tipi di mescola ad elevata dissipazione di energia: • Mescola morbida (Soft) con modulo di elasticità G = 0,4N/mm2 e smorzamento viscoso equivalente del 10% (Isolatori HDS) • Mescola intermedia (Normal) con modulo di elasticità G=0,8N/mm2 e smorzamento viscoso equivalente del 10% (Isolatori HDN) • Mescola dura (Hard) con modulo di elasticità G = 1,4N/mm2 e smorzamento viscoso equivalente del 16% (Isolatori HDH) ALGA developed several types of rubber compounds in order to match different design needs. For HDRB isolators 3 high dissipating compounds are available: • Soft compound, with modulus of elasticity G= 0,4N/mm2 and 10% equivalent viscous damping (HDS Isolators) • Normal compound, with modulus of elasticity G=0,8N/mm2 and 10% equivalent viscous damping (HDN Isolators) • Hard compound, with modulus of elasticity G=1,4N/mm2 and 16% equivalent viscous damping (HDH Isolators) Per gli LRB sono disponibili due tipi di mescola a seconda delle applicazioni: • Una mescola morbida (Soft) con modulo di elasticità G = 0,4N/mm2 e smorzamento viscoso equivalente del 10%, la stessa utilizzata per gli HDRB (Isolatori tipo LRS) • Una mescola normale (Normal) con modulo di elasticità G = 0,9N/mm2 e smorzamento viscoso equivalente del 4% (Isolatori tipo LRN). For the LRB isolators 2 type of compound are available: • Soft compound, with modulus of elasticity G = 0,4N/ mm2 and 10% equivalent viscous damping, the same used also for HDRB (LRS Isolators) • Normal compound, with modulus of elasticity G=0,9N/mm2 and 4% equivalent viscous damping (LRN Isolators). Caratteristiche fisico-meccaniche delle mescole Rubber compound phisical-mechanical characteristic Durezza / Hardness Shore A3 Mescola / Compound Normale nd / Normal nd Morbida / Soft Normale / Normal Dura / Hard 50±3 40±3 60±3 75±3 Resistenza a rottura / Tensile strength N/mm 20 20 20 18 Allungamento a rottura / Tensile strain % 600 750 600 500 N/mm2 0,9 0,4 0,8 1,4 Smorzamento viscoso equivalente del solo elastomero/ Viscous damping of the rubber % 4 10 10 16 Smorzamento viscoso equivalente dell’intero isolatore / Equivalent viscous damping % 20%-40% 20%-40% (LRS) 10% (HDS) 10 16 LRN LRS / HDS HDN HDH Modulo di elasticità G / G Modulus 2 Isolatore corrispondente / Corresponding Isolator 7 Kr - rigidezza orizzontale /horizontal stiffness In this page are represented the typical hysteresis diagrams for an HDRB (above) and an LRB (below). The technical parameters are indicated in the dimensional tables in the following pages. In the LRB diagram you may notice the lead core and the rubber's contribution. In questa pagina sono rappresentati i tipici diagrammi di isteresi di un HDRB (sopra) e di un LRB (sotto). I relativi parametri di riferimento indicati sono specificati nelle tabelle prestazionali delle pagine seguenti. Nel diagramma del LRB si può apprezzare in particolare il contributo del nucleo in piombo e della gomma. Kr - rigidezza orizzontale, contributo elastomero - horizontal stiffness, elastomer contribution Klead - rigidezza orizzontale, contributo nucleo in piombo - horizontal stiffness, lead core contribution 8 Keff - rigidezza orizzontale efficace - effective horizontal stiffness Modellazione matematica HDRB Mathematical Modeling of HDRB Isolators Secondo l’Eurocodice 8 (EN1998) una struttura può essere modellata come lineare se lo smorzamento viscoso equivalente è ≤ 30%. Questo è sempre soddisfatto per gli ALGASISM HDRB. Gli HDRB possono sempre essere modellati come lineari equivalenti esprimendo le loro caratteristiche attraverso i due parametri sintetici: Kr Rigidezza orizzontale ξ Smorzamento viscoso equivalente i cui valori per le varie geometrie e composizioni sono dati nelle tabelle dimensionali alle pagine seguenti. Occorre fare attenzione che nelle tabelle i valori dati sono riferiti alla temperatura di +20°C e ad una deformazione tangenziale del 100%. Il valore di Kr va eventualmente adeguato a condizioni differenti in base alle curve di variazione qui sotto riportate HDRB isolators can always be modelled as linear equivalent by expressing their characteristics in terms of two synthetic parameters: Kr horizontal stiffness ξ equivalent viscous damping Values for these are given in the tables on the following pages in correspondence with various geometries and compositions. Note that the values given in the tables are referenced to a temperature of +20°C and a shear deformation of 100%. The value for Kr may need to be modified to fit to different conditions; in such case the value can be taken from the below reported plots. 3,00 1,60 2,50 Relative stiffness 2,00 1,34 1,50 1,14 1,00 1,00 0,50 0,91 -30 -20 -10 0 10 20 30 40 0,00 50 0,50 1,00 1,50 2,00 2,50 3,00 TAN GAMMA Temperature (°C) Variazione relativa della rigidezza in funzione della temperatura Relative variation of stiffness as a function of temperature Variazione relativa della rigidezza in funzione della deformazione tangenziale Relative variation of stiffness as a function of shear strain (shear deformation) Se la struttura al di sopra degli isolatori può essere assimilata ad un corpo rigido, per effettuare il calcolo lineare secondo lo spettro di risposta si può seguire la seguente procedura: To perform the linear equivalent calculation with response spectrum of an isolated structure you can follow the following steps: 1) Determinare lo spettro di risposta di progetto della zona in esame. 2) Scegliere un valore ipotetico di periodo proprio (T) per la struttura isolata (normalmente il periodo proprio di una struttura isolata è intorno ai 2,5 – 3 secondi). 3) Determinare la massa sismica (M) totale della struttura 4) Determinare il centro di massa della struttura. 5) Dato il periodo proprio (T) del sistema isolato e data la massa (M), si può determinare la rigidezza globale necessaria (Kr) del sistema di isolamento attraverso la seguente relazione: 2 1) Determine the response spectrum of the area under consideration. 2) Choose a hypothetical value of the natural period for the isolated structure (normally 2.5 - 3 seconds). 3) Determine the total seismic mass of the structure. 4) Determine the centre of mass of the structure. 5) Given the natural period (T) of the isolated system and the mass (M), we can determine the overall stiffness needed (Kr) for the isolation system through the following equation: Κr = 4.π .Μ Τ2 Κr = 6) Choose the isolators among the dimension tables in the following pages. Take into account the overall stiffness (the sum of stiffness of each isolator shall be as far as possible equal to Kr), the vertical load for each isolator and the horizontal displacement that can be calculated using the following formula: 6) Scegliere, tra le tabelle dimensionali alle pagine seguenti, gli isolatori adatti alla situazione specifica tenendo conto della rigidezza globale (la somma delle rigidezze dei singoli isolatori deve essere più possibile uguale a Kr), del carico verticale per ciascun isolatore e dello spostamento orizzontale sismico che può essere calcolato con la seguente formula: Smax = ag . ( Τ 2.π 4 . π2 . Μ Τ2 ) 2 Smax = ag . 9 ( Τ 2.π ) 2 7) Select the locations to install the isolators in the structure (normally under each column) so that the centre of stiffness is as close as possible to the centre of mass. In this way during the earthquake only the translational vibration modes are activated while any torsional vibration mode (extremely harmful and dangerous) will be negligeable. The translational modes of vibration have the obvious advantage of working all isolators in the same way. For better alignment of the centres of mass and stiffness, in some cases, you can have simple free sliding bearings (such as ALGAPOT or ALGASFERON) carrying the vertical load like the isolators but with zero stiffness. 8) Once the isolators have been chosen, you need to sharpen the response spectrum by inserting the value of effective damping of the isolators themselves, by the following factor 7) Determinare in quali punti della struttura disporre gli isolatori scelti (normalmente sotto a ciascun pilastro) in modo che il centro delle rigidezze sia il più vicino possibile al centro delle masse. In questo modo in fase sismica si attiveranno solo i modi di vibrare traslazionali mentre eventuali modi di vibrare torsionali (estremamente dannosi e pericolosi) si attiveranno solo in minima parte. I modi di vibrare traslazionali hanno l’evidente vantaggio di far collaborare tutti gli isolatori allo stesso modo. Si tenga presente che per far coincidere i centri di massa e rigidezza, in alcuni punti è possibile disporre dei semplici appoggi multi direzionali (del tipo ALGAPOT o ALGASFERON) che portano il carico verticale come degli isolatori ma hanno rigidezza nulla. 8) Una volta scelti gli isolatori, occorre affinare lo spettro di risposta in modo da inserire il valore di smorzamento effettivo degli isolatori stessi, riducendo lo spettro del fattore: η= √ 10 ⎯⎯ 5+ξ η= √ 10 ⎯⎯ 5+ξ 9) Effettuare l’analisi lineare modale 10) Verificare i seguenti punti analizzando i risultati. 9) Carry out the linear modal analysis 11) Check the following points by analyzing the results. • Se si riscontrano carichi verticali e/o spostamenti maggiori di quelli ipotizzati è necessario cambiare i dispositivi scelti, senza cambiare però la rigidezza totale del sistema. • Se le forze sismiche nella struttura rimangono troppo elevate, è necessario aumentare l’isolamento. Questo si può effettuare o aumentando il periodo proprio del sistema isolato (ripetere l’analisi dal p.to2) o aumentando lo smorzamento dei dispositivi, passando per esempio ad una mescola Hard (dissipazione fino al 16%) o a un dispositivo tipo ALGASISM LRB (dissipazione fino al 30%). • If you have vertical loads and / or displacement greater than expected you need to change the chosen devices, but without changing the overall stiffness of the system. • If the seismic forces in the structure remain too high, it is necessary to increase the isolation. This can be made either by increasing the natural period of the isolated system (repeat the analysis from p.2) or by increasing the damping devices by passing, for example, to a Hard compound (dissipation up to 16%) or to a device like ALGASISM LRB ( dissipation up to 30%). Modellazione matematica LRB Mathematical Modeling of LRB Isolators Il loro comportamento può essere definito attraverso tre parametri Their behaviour can be defined throughout the following parameters: Fy Klead Kr Fy Klead Kr Carico di snervamento del nucleo in piombo rigidezza orizzontale (contributo nucleo in piombo) rigidezza orizzontale (contributo elastomero) i cui valori per le varie geometrie disponibili sono dati nelle tabelle alle pagine seguenti. Il calcolo lineare equivalente può essere effettuato, sotto le stesse ipotesi, analogamente a quanto spiegato al paragrafo precedente per gli isolatori HDRB ma sostituendo alla rigidezza Kr la rigidezza orizzontale efficace Keff e al valore ξ il valore dello smorzamento viscoso efficace βr (entrambi questi parametri sono dati nelle tabelle dimensionali). Yield point load for lead core Horizontal stiffness (lead core contribution) Horizontal stiffness (elastomer contribution) The values for these parameters are given in the dimensional tables in the following pages. The linear equivalent calculation, under the same hypothesis, can be made with the same procedure given in the previous paragraph for the HDRB isolators but with these differences: • Instead of Kr consider the effective horizontal stiffness Keff • Instead of ξ consider the effective damping βr. Occorre tener presente che il comportamento degli isolatori LRB è fortemente non lineare. Ciò implica che la rigidezza efficace Keff così come lo smorzamento viscoso efficace βr così come indicati nelle tabelle sono validi solo per lo spostamento di progetto dato Smax. L’analisi modale va di conseguenza reiterata anche se si ottengono dall’analisi spostamenti minori di quelli ipotizzati. Keep in mind that LRB isolators are strongly non linear. This means that parameters Keff and βr values as indicated in the dimension tables are valid only for the design displacement Smax. Therefore you have to perform again the modal analysis even if your calculated displacement is lower than the hypothesized. 10 Centro Telecom di Ancona, il primo edificio sismicamente isolato in Europa (Italia, 1987) The Telecom Center in Ancona, the first seismic isolated building in Europe (Italy, 1987) ALGASISM HDRB Tabelle prestazionali Le tabelle seguenti riportano le caratteristiche tipiche degli isolatori circolari di uso più comune. Possono essere prodotti a richiesta isolatori con caratteristiche differenti, di forma quadrata o rettangolare o per risolvere specifici problemi strutturali quali per esempio carichi negativi o modifiche di schema statico. Performance Tables The following tables report the typical characteristics for the most commonly used isolators, those of circular shape. Isolators with different characteristics rather of square or rectangular shape or to resolve specific structural problems as for instance uplift loads can be produced on request. Il nome HDRB è composto come segue: HD”X” DxH, dove: “X” indica il tipo di mescola utilizzata, “S” per soft, “N” per Normal e “H” per Hard D è il diametro dell’elastomero (in mm) H è l’altezza dell’isolatore (in mm) Per esempio HDH 1200x120 indica un isolatore tipo HDRB con mescola Hard (H) avente modulo G = 1,4N/mm2, diametro 1200mm e altezza 120mm. The HDRB code is composed as follows: HD”X” DxH, where: “X” is the rubber compound used, “S” for soft, “N” for Normal and “H” for Hard D is the rubber diameter (mm) H is the height of the isolator (mm) For example HDH 1200x120 stands for an isolator type HDRB with a Hard compound with modulus of elasticity G = 1,4N/mm2, diameter D 1200mm and 120mm height. 11 Legenda | Legend HDS (High Damping Soft) G=0,4N/mm2 – ξ=10%. HDN (High Damping Normal) G=0,8N/mm2 – ξ=10% HDH (High Damping Hard) G=1,4N/mm2 – ξ=16% Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale Horizontal stiffness Smax Spostamento di progetto Design displacement ξ Smorzamento viscoso della gomma Viscous damping of the rubber HDS Vmax Vsism Kr [kN] [kN] [kN/mm] Dati geometrici | Geometrical Data D Diametro elastomero Diameter of the elastomer H Altezza totale isolatore Overall height of the isolator te Spessore elastomero Thickness of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B HDN Vmax Vsism Kr [kN] [kN] [kN/mm] HDH Vmax Vsism Kr H te Smax [kN] [kN] [kN/mm] [mm] [mm] [mm] 2900 3050 3100 2750 2500 2250 1050 1900 1750 2500 2100 1800 1500 1300 1150 1000 900 750 2,06 1,83 1,65 1,50 1,37 1,27 1,18 1,10 1,03 132 140 148 156 164 172 180 188 196 48 54 60 66 72 78 84 90 96 100 110 120 140 150 160 170 180 200 3850 4000 4200 4300 3850 3500 3150 2900 2650 2450 3850 3400 2800 2550 2100 1750 1550 1400 1250 1050 2,75 2,41 2,14 1,92 1,75 1,60 1,48 1,37 1,28 1,20 143 154 165 176 187 198 197 207 217 227 49 56 63 70 77 84 91 98 105 112 100 120 130 140 160 170 190 200 210 230 4650 5000 5350 5500 5650 5100 4600 4200 3800 3550 3250 4650 5000 4650 3850 3350 2800 2400 2150 1850 1650 1400 3,67 3,14 2,75 2,44 2,20 2,00 1,83 1,69 1,57 1,47 1,37 138 150 162 174 195 198 210 222 221 232 243 48 56 64 72 80 88 96 104 112 120 128 100 120 130 150 160 180 200 210 230 240 260 5500 6250 6850 7200 7550 7700 7650 7000 6350 5800 5450 5000 5500 6250 6850 6650 5800 5000 4200 3850 3300 3000 2600 2300 4,64 3,98 3,48 3,09 2,78 2,53 2,32 2,14 1,99 1,86 1,74 1,64 133 150 162 182 195 208 221 234 234 246 258 270 48 56 64 72 80 88 96 104 112 120 128 136 100 120 130 150 160 180 200 210 230 240 260 280 Diametro elastomero / Elastomer diameter D = 300mm HDS300X48 HDS300X54 HDS300X60 HDS300X66 HDS300X72 HDS300X78 HDS300X84 HDS300X90 HDS300X96 800 800 800 750 700 650 550 550 500 650 600 520 430 370 330 290 250 210 0,59 0,52 0,47 0,43 0,39 0,36 0,34 0,31 0,29 HDN300X48 HDN300X54 HDN300X60 HDN300X66 HDN300X72 HDN300X78 HDN300X84 HDN300X90 HDN300X96 1650 1700 1750 1550 1400 1300 1150 1100 1000 1400 1200 1000 850 750 650 550 500 400 1,18 1,05 0,94 0,86 0,79 0,72 0,67 0,63 0,59 HDH300X48 HDH300X54 HDH300X60 HDH300X66 HDH300X72 HDH300X78 HDH300X84 HDH300X90 HDH300X96 Diametro elastomero / Elastomer diameter D = 350 HDS350X49 HDS350X56 HDS350X63 HDS350X70 HDS350X77 HDS350X84 HDS350X91 HDS350X98 HDS350X105 HDS350X112 1100 1150 1200 1200 1100 1000 900 800 750 700 1100 950 800 700 600 500 450 400 350 300 0,79 0,69 0,61 0,55 0,50 0,46 0,42 0,39 0,37 0,34 HDN350X49 HDN350X56 HDN350X63 HDN350X70 HDN350X77 HDN350X84 HDN350X91 HDN350X98 HDN350X105 HDN350X112 2200 2300 2350 2450 2200 2000 1800 1650 1500 1400 2200 1950 1650 1450 1200 1050 900 800 700 600 1,57 1,37 1,22 1,10 1,00 0,92 0,85 0,79 0,73 0,69 HDH350X49 HDH350X56 HDH350X63 HDH350X70 HDH350X77 HDH350X84 HDH350X91 HDH350X98 HDH350X105 HDH350X112 Diametro elastomero / Elastomer diameter D = 400 HDS400X48 HDS400X56 HDS400X64 HDS400X72 HDS400X80 HDS400X88 HDS400X96 HDS400X104 HDS400X112 HDS400X120 HDS400X128 1300 1400 1500 1550 1600 1450 1300 1200 1050 1000 900 1300 1400 1300 1100 950 800 650 600 500 450 400 1,05 0,90 0,79 0,70 0,63 0,57 0,52 0,48 0,45 0,42 0,39 HDN400X48 HDN400X56 HDN400X64 HDN400X72 HDN400X80 HDN400X88 HDN400X96 HDN400X104 HDN400X112 HDN400X120 HDN400X128 2650 2850 3050 3150 3250 2900 2600 2400 2150 2000 1850 2650 2850 2650 2200 1900 1600 1350 1200 1050 950 800 2,09 1,80 1,57 1,40 1,26 1,14 1,05 0,97 0,90 0,84 0,79 HDH400X48 HDH400X56 HDH400X64 HDH400X72 HDH400X80 HDH400X88 HDH400X96 HDH400X104 HDH400X112 HDH400X120 HDH400X128 Diametro elastomero / Elastomer diameter D = 450 HDS450X48 HDS450X56 HDS450X64 HDS450X72 HDS450X80 HDS450X88 HDS450X96 HDS450X104 HDS450X112 HDS450X120 HDS450X128 HDS450X136 1550 1750 1950 2050 2150 2200 2150 2000 1800 1650 1550 1400 1550 1750 1950 1900 1650 1400 1200 1100 950 850 750 650 1,33 1,14 0,99 0,88 0,80 0,72 0,66 0,61 0,57 0,53 0,50 0,47 HDN450X48 HDN450X56 HDN450X64 HDN450X72 HDN450X80 HDN450X88 HDN450X96 HDN450X104 HDN450X112 HDN450X120 HDN450X128 HDN450X136 3150 3550 3900 4100 4300 4400 4350 4000 3650 3350 3100 2850 3150 3550 3900 3800 3300 2850 2450 2200 1900 1700 1500 1300 12 2,65 2,27 1,99 1,77 1,59 1,45 1,33 1,22 1,14 1,06 0,99 0,94 HDH450X48 HDH450X56 HDH450X64 HDH450X72 HDH450X80 HDH450X88 HDH450X96 HDH450X104 HDH450X112 HDH450X120 HDH450X128 HDH450X136 Legenda | Legend HDS (High Damping Soft) G=0,4N/mm2 – ξ=10%. HDN (High Damping Normal) G=0,8N/mm2 – ξ=10% HDH (High Damping Hard) G=1,4N/mm2 – ξ=16% Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale Horizontal stiffness Smax Spostamento di progetto Design displacement ξ Smorzamento viscoso della gomma Viscous damping of the rubber HDS Dati geometrici | Geometrical Data D Diametro elastomero Diameter of the elastomer H Altezza totale isolatore Overall height of the isolator te Spessore elastomero Thickness of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B Vmax Vsism Kr Vmax Vsism Kr [kN] [kN] [kN/mm] [kN] [kN] [kN/mm] HDH Vmax Vsism Kr Kr H te Smax [kN] [kN] [kN/mm] [kN/mm] [mm] [mm] [mm] Diametro elastomero / Elastomer diameter D = 500 HDS500X50 HDS500X60 1850 2100 1850 2100 1,57 1,31 HDN500X50 HDN500X60 3700 4250 3700 4250 3,14 2,62 HDH500X50 HDH500X60 6500 7450 6500 7450 5,50 4,58 156 175 50 60 100 120 HDS500X70 2300 2300 1,12 HDN500X70 4600 4600 2,24 HDH500X70 8100 8100 3,93 190 70 140 HDS500X80 HDS500X90 HDS500X100 HDS500X110 HDS500X120 HDS500X130 HDS500X140 HDS500X150 HDS500X160 HDS500X170 2400 2500 2550 2350 2100 1900 1750 1600 1450 1350 2150 1800 1500 1300 1150 1000 850 750 650 550 0,98 0,87 0,79 0,71 0,65 0,60 0,56 0,52 0,49 0,46 HDN500X80 HDN500X90 HDN500X100 HDN500X110 HDN500X120 HDN500X130 HDN500X140 HDN500X150 HDN500X160 HDN500X170 4850 5000 5150 4700 4250 3850 3500 3200 2950 2750 4300 3600 3050 2650 2300 2000 1700 1500 1300 1150 1,96 1,75 1,57 1,43 1,31 1,21 1,12 1,05 0,98 0,92 HDH500X80 HDH500X90 HDH500X100 HDH500X110 HDH500X120 HDH500X130 HDH500X140 HDH500X150 HDH500X160 HDH500X170 8450 8800 9000 8200 7400 6750 6150 5650 5200 4800 7500 6350 5400 4650 4000 3500 3050 2650 2300 2050 3,44 3,05 2,75 2,50 2,29 2,11 1,96 1,83 1,72 1,62 205 220 244 250 265 280 282 296 310 324 80 90 100 110 120 130 140 150 160 170 160 180 200 220 240 260 280 300 320 340 7900 8950 9700 10250 10700 10900 9950 9000 8200 7500 6900 6350 7900 8950 9700 9100 7700 6600 5550 4800 4200 3700 3250 2750 6,05 5,04 4,32 3,78 3,36 3,02 2,75 2,52 2,33 2,16 2,02 1,89 161 181 197 220 237 254 271 277 293 309 311 326 55 66 77 88 99 110 121 132 143 154 165 176 110 140 160 180 200 220 250 270 290 310 330 360 9450 9450 10700 10700 11700 11700 12250 10800 12600 9200 11950 6700 10850 5850 9800 5000 8950 4400 8250 3900 7600 3350 7050 2950 6,60 5,50 4,71 4,12 3,67 3,00 2,75 2,54 2,36 2,20 2,06 1,94 170 187 210 228 246 282 300 306 323 340 342 358 60 72 84 96 108 132 144 156 168 180 192 204 120 150 170 200 220 270 290 320 340 360 390 410 Diametro elastomero / Elastomer diameter D = 550 HDS550X55 HDS550X66 HDS550X77 HDS550X88 HDS550X99 HDS550X110 HDS550X121 HDS550X132 HDS550X143 HDS550X154 HDS550X165 HDS550X176 2250 2550 2750 2900 3050 3100 2850 2550 2300 2150 1950 1800 2250 2550 2750 2600 2200 1850 1550 1350 1200 1050 900 750 1,73 1,44 1,23 1,08 0,96 0,86 0,79 0,72 0,66 0,62 0,58 0,54 HDN550X55 HDN550X66 HDN550X77 HDN550X88 HDN550X99 HDN550X110 HDN550X121 HDN550X132 HDN550X143 HDN550X154 HDN550X165 HDN550X176 4500 5100 5550 5850 6100 6250 5700 5150 4650 4300 3950 3600 4500 5100 5550 5200 4400 3750 3150 2750 2400 2100 1850 1550 3,46 2,88 2,47 2,16 1,92 1,73 1,57 1,44 1,33 1,23 1,15 1,08 HDH550X55 HDH550X66 HDH550X77 HDH550X88 HDH550X99 HDH550X110 HDH550X121 HDH550X132 HDH550X143 HDH550X154 HDH550X165 HDH550X176 Diametro elastomero / Elastomer diameter D = 600 HDS600X60 HDS600X72 HDS600X84 HDS600X96 HDS600X108 HDS600X132 HDS600X144 HDS600X156 HDS600X168 HDS600X180 HDS600X192 HDS600X204 2700 3050 3350 3500 3600 3400 3100 2800 2550 2350 2150 2000 2700 3050 3350 3050 2600 1900 1650 1400 1250 1100 950 850 1,88 1,57 1,35 1,18 1,05 0,86 0,79 0,72 0,67 0,63 0,59 0,55 HDN600X60 HDN600X72 HDN600X84 HDN600X96 HDN600X108 HDN600X132 HDN600X144 HDN600X156 HDN600X168 HDN600X180 HDN600X192 HDN600X204 5400 6100 6700 7000 7200 6850 6200 5600 5100 4700 4300 4000 5400 6100 6700 6150 5250 3800 3350 2850 2500 2200 1900 1700 13 3,77 3,14 2,69 2,36 2,09 1,71 1,57 1,45 1,35 1,26 1,18 1,11 HDH600X60 HDH600X72 HDH600X84 HDH600X96 HDH600X108 HDH600X132 HDH600X144 HDH600X156 HDH600X168 HDH600X180 HDH600X192 HDH600X204 Legenda | Legend HDS (High Damping Soft) G=0,4N/mm2 – ξ=10%. HDN (High Damping Normal) G=0,8N/mm2 – ξ=10% HDH (High Damping Hard) G=1,4N/mm2 – ξ=16% Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale Horizontal stiffness Smax Spostamento di progetto Design displacement ξ Smorzamento viscoso della gomma Viscous damping of the rubber HDS Vmax Vsism Kr [kN] [kN] [kN/mm] Dati geometrici | Geometrical Data D Diametro elastomero Diameter of the elastomer H Altezza totale isolatore Overall height of the isolator te Spessore elastomero Thickness of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B HDN Vmax Vsism Kr [kN] [kN] [kN/mm] HDH Vmax Vsism Kr H te Smax [kN] [kN] [kN/mm] [mm] [mm] [mm] Diametro elastomero / Elastomer diameter D = 650 HDS650X65 HDS650X78 HDS650X91 3150 3600 3900 3150 3600 3900 2,04 1,70 1,46 HDN650X65 HDN650X78 HDN650X91 6350 7200 7800 6350 7200 7800 4,08 3,40 2,92 HDH650X65 HDH650X78 HDH650X91 11050 11050 12600 12600 13650 13650 7,15 5,96 5,11 175 198 217 65 78 91 130 160 190 HDS650X104 HDS650X117 HDS650X130 HDS650X143 HDS650X156 HDS650X169 HDS650X182 HDS650X195 HDS650X208 4150 4250 4400 4000 3600 3300 3000 2750 2550 3700 3050 2650 2250 1950 1700 1450 1300 1100 1,28 1,13 1,02 0,93 0,85 0,79 0,73 0,68 0,64 HDN650X104 HDN650X117 HDN650X130 HDN650X143 HDN650X156 HDN650X169 HDN650X182 HDN650X195 HDN650X208 8300 8500 8800 8000 7200 6600 6000 5500 5100 7400 6100 5300 4500 3900 3400 2900 2600 2200 2,55 2,27 2,04 1,86 1,70 1,57 1,46 1,36 1,28 HDH650X104 HDH650X117 HDH650X130 HDH650X143 HDH650X156 HDH650X169 HDH650X182 HDH650X195 HDH650X208 14525 12950 14900 10800 15400 9350 14100 7950 12700 6800 11600 6000 10600 5200 9700 4600 9000 4000 4,47 3,97 3,57 3,25 2,98 2,75 2,55 2,38 2,23 243 263 283 303 312 331 337 355 373 104 117 130 143 156 169 182 195 208 210 240 260 290 320 340 370 390 420 Diametro elastomero / Elastomer diameter D = 700 HDS700X70 HDS700X84 HDS700X98 HDS700X112 HDS700X126 HDS700X140 HDS700X154 HDS700X168 3650 4200 4550 4800 4950 5100 4700 4200 3650 4200 4550 4250 3550 3100 2650 2300 2,20 1,83 1,57 1,37 1,22 1,10 1,00 0,92 HDN700X70 HDN700X84 HDN700X98 HDN700X112 HDN700X126 HDN700X140 HDN700X154 HDN700X168 7300 8400 9100 9600 9900 10200 9400 8400 7300 8400 9100 8500 7100 6200 5300 4600 4,40 3,67 3,14 2,75 2,44 2,20 2,00 1,83 HDH700X70 HDH700X84 HDH700X98 HDH700X112 HDH700X126 HDH700X140 HDH700X154 HDH700X168 12900 14750 16000 16800 17350 17900 16500 14900 12900 14750 16000 14900 12550 10900 9300 8050 7,70 6,41 5,50 4,81 4,28 3,85 3,50 3,21 180 204 230 251 272 302 314 335 70 84 98 112 126 140 154 168 140 170 200 230 260 280 310 340 HDS700X182 HDS700X196 HDS700X210 3850 3500 3250 1950 1700 1500 0,85 0,79 0,73 HDN700X182 HDN700X196 HDN700X210 7700 7000 6500 3900 3400 3000 1,69 1,57 1,47 HDH700X182 HDH700X196 HDH700X210 13500 12250 11400 6950 6050 5400 2,96 2,75 2,57 344 364 370 182 196 210 370 400 420 14700 17000 18400 19500 20150 20650 18900 17150 15600 14200 14700 17000 18400 17450 14700 12450 10800 9350 8150 7100 8,25 6,87 5,89 5,15 4,58 4,12 3,75 3,44 3,17 2,95 189 215 237 266 289 312 335 347 369 378 75 90 105 120 135 150 165 180 195 210 150 180 210 240 270 300 330 360 390 420 16800 19150 20900 22050 22950 23500 21550 17700 16800 19150 20900 19800 16650 14350 12100 9100 8,80 7,33 6,28 5,50 4,89 4,40 4,00 3,38 214 241 270 294 326 351 366 402 80 96 112 128 144 160 176 208 160 200 230 260 290 320 360 420 Diametro elastomero / Elastomer diameter D = 750 HDS750X75 HDS750X90 HDS750X105 HDS750X120 HDS750X135 HDS750X150 HDS750X165 HDS750X180 HDS750X195 HDS750X210 4200 4850 5250 5550 5750 5900 5400 4900 4450 4050 4200 4850 5250 4950 4200 3550 3050 2650 2300 2000 2,36 1,96 1,68 1,47 1,31 1,18 1,07 0,98 0,91 0,84 HDN750X75 HDN750X90 HDN750X105 HDN750X120 HDN750X135 HDN750X150 HDN750X165 HDN750X180 HDN750X195 HDN750X210 8400 8400 9700 9700 10500 10500 11100 9900 11500 8400 11800 7100 10800 6100 9800 5300 8900 4600 8100 4050 4,71 3,93 3,37 2,95 2,62 2,36 2,14 1,96 1,81 1,68 HDH750X75 HDH750X90 HDH750X105 HDH750X120 HDH750X135 HDH750X150 HDH750X165 HDH750X180 HDH750X195 HDH750X210 Diametro elastomero / Elastomer diameter D = 800 HDS800X80 HDS800X96 HDS800X112 HDS800X128 HDS800X144 HDS800X160 HDS800X176 HDS800X208 4800 5450 5950 6300 6550 6700 6150 5050 4800 5450 5950 5650 4750 4100 3450 2600 2,51 2,09 1,80 1,57 1,40 1,26 1,14 0,97 HDN800X80 HDN800X96 HDN800X112 HDN800X128 HDN800X144 HDN800X160 HDN800X176 HDN800X208 9600 9600 10900 10900 11900 11900 12600 11300 13100 9500 13400 8200 12350 6900 10100 5200 14 5,03 4,19 3,59 3,14 2,79 2,51 2,28 1,93 HDH800X80 HDH800X96 HDH800X112 HDH800X128 HDH800X144 HDH800X160 HDH800X176 HDH800X208 Legenda | Legend HDS (High Damping Soft) G=0,4N/mm2 – ξ=10%. HDN (High Damping Normal) G=0,8N/mm2 – ξ=10% HDH (High Damping Hard) G=1,4N/mm2 – ξ=16% Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale Horizontal stiffness Smax Spostamento di progetto Design displacement ξ Smorzamento viscoso della gomma Viscous damping of the rubber HDS Dati geometrici | Geometrical Data D Diametro elastomero Diameter of the elastomer H Altezza totale isolatore Overall height of the isolator te Spessore elastomero Thickness of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B Vmax Vsism Kr Vmax Vsism Kr [kN] [kN] [kN/mm] [kN] [kN] [kN/mm] HDH Vmax Vsism Kr Kr H te Smax [kN] [kN] [kN/mm] [kN/mm] [mm] [mm] [mm] Diametro elastomero / Elastomer diameter D = 900 HDS900X90 HDS900X108 HDS900X126 6100 7000 7500 6100 7000 7500 2,83 2,36 2,02 HDN900X90 HDN900X108 HDN900X126 12200 12200 14000 14000 15000 15000 5,65 4,71 4,04 HDH900X90 HDH900X108 HDH900X126 21350 21350 24500 24500 26250 26250 9,90 8,25 7,07 228 258 284 90 108 126 180 220 260 HDS900X144 HDS900X162 HDS900X180 HDS900X198 8000 8300 8500 7900 7200 6050 5200 4450 1,77 1,57 1,41 1,29 HDN900X144 HDN900X162 HDN900X180 HDN900X198 16000 14400 16600 12100 17000 10400 15800 8900 3,53 3,14 2,83 2,57 HDH900X144 HDH900X162 HDH900X180 HDH900X198 28000 29050 29750 27650 25200 21200 18200 15600 6,19 5,50 4,95 4,50 317 352 380 398 144 162 180 198 290 330 360 400 26400 30300 33100 34900 36050 36750 34300 26400 30300 33100 31500 26600 22600 19450 11,00 9,16 7,85 6,87 6,11 5,50 5,00 258 295 324 360 398 429 450 100 120 140 160 180 200 220 200 240 280 320 360 400 440 Diametro elastomero / Elastomer diameter D = 1000 HDS1000X100 HDS1000X120 HDS1000X140 HDS1000X160 HDS1000X180 HDS1000X200 HDS1000X220 7550 8650 9450 9950 10300 10500 9800 7550 8650 9450 9000 7600 6450 5550 3,14 2,62 2,24 1,96 1,75 1,57 1,43 HDN1000X100 HDN1000X120 HDN1000X140 HDN1000X160 HDN1000X180 HDN1000X200 HDN1000X220 15100 17300 18900 19900 20600 21000 19600 15100 17300 18900 18000 15200 12900 11100 6,28 5,24 4,49 3,93 3,49 3,14 2,86 HDH1000X100 HDH1000X120 HDH1000X140 HDH1000X160 HDH1000X180 HDH1000X200 HDH1000X220 Diametro elastomero / Elastomer diameter D = 1100 HDS1100X110 HDS1100X132 HDS1100X154 HDS1100X176 9100 9100 10450 10450 11450 11450 12000 10800 3,46 2,88 2,47 2,16 HDN1100X110 HDN1100X132 HDN1100X154 HDN1100X176 18200 20900 22900 24000 18200 20900 22900 21600 6,91 5,76 4,94 4,32 HDH1100X110 HDH1100X132 HDH1100X154 HDH1100X176 31850 36600 40050 42000 31850 36600 40050 37800 12,10 10,08 8,64 7,56 272 307 344 383 110 132 154 176 220 270 310 360 HDS1100X198 HDS1100X220 12450 12800 1,92 1,73 HDN1100X198 HDN1100X220 24900 18300 12800 7850 3,84 1,73 HDH1100X198 HDH1100X220 43600 32050 44900 27500 6,72 6,05 416 458 198 220 400 440 38150 43900 47600 50250 51800 38150 43900 47600 45400 38150 13,19 11,00 9,42 8,25 7,33 286 324 364 406 442 120 144 168 192 216 240 290 340 390 440 51800 59500 64750 68600 71050 51800 15,39 59500 12,83 64750 11,00 62300 9,62 52500 8,55 310 358 404 452 502 140 168 196 224 252 280 340 400 450 510 67900 78050 85250 89600 67900 78050 85250 81200 338 387 444 498 160 192 224 256 320 390 450 520 9150 7850 Diametro elastomero / Elastomer diameter D = 1200 HDS1200X120 HDS1200X144 HDS1200X168 HDS1200X192 HDS1200X216 10900 12550 13600 14350 14800 10900 12550 13600 12950 10900 3,77 3,14 2,69 2,36 2,09 HDN1200X120 HDN1200X144 HDN1200X168 HDN1200X192 HDN1200X216 21800 25100 27200 28700 29600 21800 25100 27200 25900 21800 7,54 6,28 5,39 4,71 4,19 HDH1200X120 HDH1200X144 HDH1200X168 HDH1200X192 HDH1200X216 Diametro elastomero / Elastomer diameter D = 1400 HDS1400X140 HDS1400X168 HDS1400X196 HDS1400X224 HDS1400X252 14800 17000 18500 19600 20300 14800 17000 18500 17800 15000 4,40 3,67 3,14 2,75 2,44 HDN1400X140 HDN1400X168 HDN1400X196 HDN1400X224 HDN1400X252 29600 34000 37000 39200 40600 29600 34000 37000 35600 30000 8,80 7,33 6,28 5,50 4,89 HDH1400X140 HDH1400X168 HDH1400X196 HDH1400X224 HDH1400X252 Diametro elastomero / Elastomer diameter D = 1600 HDS1600X160 HDS1600X192 HDS1600X224 HDS1600X256 19400 22300 24350 25600 19400 22300 24350 23200 5,03 4,19 3,59 3,14 HDN1600X160 HDN1600X192 HDN1600X224 HDN1600X256 38800 44600 48700 51200 38800 10,05 HDH1600X160 44600 8,38 HDH1600X192 48700 7,18 HDH1600X224 46400 6,28 HDH1600X256 15 17,59 14,66 12,57 11,00 Il quartier generale NATO a Giugliano, Caserta Il più grande edificio sismicamente isolato in Europa (Italia, 2007) The NATO Headquarters at Giugliano, Caserta. The biggest base isolated building in Europe (Italy, 2007) ALGASISM LRB Tabelle prestazionali Nelle tabelle seguenti sono riportate le caratteristiche tipiche degli isolatori di uso più comune, di forma circolare. Possono essere prodotti a richiesta isolatori con caratteristiche differenti, di forma quadrata o rettangolare o per risolvere specifici problemi strutturali quali per esempio carichi negativi o modifiche di schema statico. Il nome LRB è composto come segue: LR”X” DxH, dove: “X” indica il tipo di mescola utilizzata, “S” per soft, “N” per Normal D è il diametro dell’elastomero (in mm) H è l’altezza dell’isolatore (in mm) Per esempio LRN 1200x120 indica un isolatore tipo LRB con mescola Normal (N) avente modulo G = 0,9N/mm2, diametro 1200mm e altezza 120mm. Performance Tables The following tables report the typical characteristics for the most commonly used isolators, those of circular shape. Isolators with different characteristics rather of square or rectangular shape or to resolve specific structural problems as for instance uplift loads can be produced on request. The LRB code is composed as follows: LR”X” DxH, where: “X” is the rubber compound used, “S” for soft, “N” for Normal D is the rubber diameter (mm) H is the height of the isolator (mm) For example LRN 1200x120 stands for an isolator type LRB with a Normal compound with modulus of elasticity G = 0,9N/mm2, diameter D 1200mm and 120mm height. 16 Legenda | Legend LRS LRS ξr= 10% - G = 0,4 MPa LRN LRN ξr= 4% - G = 0,9 MPa ξr Smorzamento viscoso della gomma Viscous damping of the rubber βeff Smorzamento efficace | Effective damping Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale (contributo elastomero) Horizontal stiffness (elastomer contribution) Klead Rigidezza orizz. (contr. nucleo in piombo) Horizontal stiffness (lead core contribution) Fy Carico di snervamento del nucleo Yield point load for lead core Keff Rigidezza orizzontale efficace Effective horizontal stiffness Smax Spostamento di progetto | Design displacement LRS Dati geometrici | Geometrical Data te Spessore elastomero Thickness of the elastomer H Altezza totale isolatore Overall height of the isolator D Diametro elastomero Diameter of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B βeff = 28% per tutti gli isolatori for all isolators Vmax Vsism Kr Klead Fy Keff [kN] [kN] [kN/mm] [kN/mm] [kN] [kN/mm] LRN Vmax Vsism Kr Klead Fy Keff H te Smax [kN] [kN] [kN/mm] [kN/mm] [%] [kN/mm] [mm] [mm] [mm] Diametro elastomero / Elastomer diameter D = 300 LRS300X48 LRS300X54 LRS300X60 750 800 800 650 550 450 0,57 0,51 0,46 6,43 5,72 4,25 26 26 22 0,81 LRN300X48 0,72 LRN300X54 0,62 LRN300X60 1450 1550 1600 1250 1050 900 1,18 1,06 0,95 21,27 17,06 15,36 83 75 75 1,96 1,70 1,54 146 156 166 48 54 60 100 110 120 LRS300X66 LRS300X72 LRS300X78 LRS300X84 LRS300X90 LRS300X96 700 650 600 550 500 450 400 350 300 250 200 0 0,41 0,38 0,35 0,33 0,31 0,28 4,68 4,29 3,96 3,68 2,84 3,22 26 26 26 26 22 26 0,58 0,54 0,50 0,47 0,41 0,40 1350 1250 1150 1050 950 850 750 650 550 500 450 350 0,86 0,79 0,73 0,68 0,64 0,59 15,47 14,18 11,81 10,97 10,24 10,64 83 83 75 75 75 83 1,42 1,31 1,18 1,10 1,03 0,98 176 175 184 193 202 211 66 72 78 84 90 96 140 150 160 170 180 200 LRN300X66 LRN300X72 LRN300X78 LRN300X84 LRN300X90 LRN300X96 Diametro elastomero / Elastomer diameter D = 350 LRS350X56 LRS350X63 LRS350X70 LRS350X77 LRS350X84 1050 1100 1150 1000 850 900 750 650 550 450 0,66 0,59 0,53 0,48 0,44 7,70 5,83 5,25 5,60 4,38 36 31 31 36 31 0,94 0,81 0,74 0,69 0,61 LRN350X56 LRN350X63 LRN350X70 LRN350X77 LRN350X84 2000 2100 2100 1900 1750 1700 1450 1250 1050 900 1,38 1,23 1,10 1,00 0,92 24,11 21,43 19,29 17,54 16,07 110 110 110 110 110 2,24 2,03 1,85 1,65 1,53 154 165 176 187 198 56 63 70 77 84 120 130 140 160 170 LRS350X91 LRS350X98 LRS350X105 LRS350X112 800 750 700 650 400 350 300 0 0,41 0,38 0,36 0,33 4,74 3,75 3,50 3,28 36 31 31 31 0,58 0,52 0,49 0,46 LRN350X91 LRN350X98 LRN350X105 LRN350X112 1550 1450 1350 1200 800 700 600 500 0,85 0,79 0,74 0,69 14,84 13,78 12,86 12,06 110 110 110 110 1,40 1,31 1,23 1,14 197 207 217 227 91 98 105 112 190 200 210 230 2,11 1,79 1,58 1,40 1,26 1,15 1,05 0,97 0,90 0,84 35,95 33,23 26,96 23,97 21,57 19,61 17,97 16,59 15,41 14,38 141 151 141 141 141 141 141 141 141 141 3,43 2,98 2,60 2,29 2,09 1,89 1,72 1,60 1,48 1,40 165 181 203 220 245 263 281 288 305 309 138 150 169 182 195 208 210 222 234 246 100 120 130 150 160 180 200 210 230 240 2,65 2,27 2,00 1,77 1,60 1,46 1,33 1,23 1,15 1,07 1,00 0,95 47,86 41,02 33,54 31,91 26,83 24,39 23,93 20,64 19,17 17,89 16,77 14,71 187 187 175 187 175 175 187 175 175 175 175 164 4,42 3,74 3,27 2,95 2,64 2,38 2,21 2,02 1,86 1,76 1,64 1,50 138 150 169 182 195 218 221 234 247 260 258 270 48 56 64 72 80 88 96 104 112 120 128 136 100 120 130 150 160 180 200 210 230 240 260 280 Diametro elastomero / Elastomer diameter D = 400 LRS400X48 LRS400X56 LRS400X64 LRS400X72 LRS400X80 LRS400X88 LRS400X96 LRS400X104 LRS400X112 LRS400X120 1250 1300 1400 1450 1500 1350 1200 1100 1000 950 1250 1250 1250 1000 900 750 650 550 450 400 1,02 0,87 0,76 0,68 0,61 0,55 0,51 0,47 0,44 0,41 10,42 10,26 7,82 6,95 6,25 5,69 5,21 4,81 4,47 4,17 42 48 42 42 42 42 42 42 42 42 1,40 1,23 1,06 0,93 0,85 0,77 0,70 0,65 0,60 0,57 LRN400X48 LRN400X56 LRN400X64 LRN400X72 LRN400X80 LRN400X88 LRN400X96 LRN400X104 LRN400X112 LRN400X120 2350 2500 2700 2800 2850 2600 2300 2100 1950 1800 2350 2500 2350 1950 1700 1450 1200 1100 900 800 Diametro elastomero / Elastomer diameter D = 450 LRS450X48 LRS450X56 LRS450X64 LRS450X72 LRS450X80 LRS450X88 LRS450X96 LRS450X104 LRS450X112 LRS450X120 LRS450X128 LRS450X136 1450 1650 1800 1900 2000 2050 2000 1850 1700 1550 1450 1300 1450 1650 1800 1900 1450 1300 1150 1000 850 800 700 0 1,28 1,10 0,96 0,86 0,77 0,70 0,64 0,59 0,55 0,51 0,48 0,45 13,61 13,17 10,21 9,08 8,17 7,43 6,81 6,28 5,83 5,45 5,11 4,80 55 61 55 55 55 55 55 55 55 55 55 55 1,79 1,57 1,35 1,19 1,08 0,98 0,89 0,83 0,77 0,72 0,67 0,63 LRN450X48 LRN450X56 LRN450X64 LRN450X72 LRN450X80 LRN450X88 LRN450X96 LRN450X104 LRN450X112 LRN450X120 LRN450X128 LRN450X136 17 2750 3100 3500 3600 3850 3950 3800 3550 3250 3000 2750 2600 2750 3100 3500 3350 2950 2550 2150 1950 1700 1500 1300 1150 Legenda | Legend LRS LRS ξr= 10% - G = 0,4 MPa LRN LRN ξr= 4% - G = 0,9 MPa ξr Smorzamento viscoso della gomma Viscous damping of the rubber βeff Smorzamento efficace | Effective damping Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale (contributo elastomero) Horizontal stiffness (elastomer contribution) Klead Rigidezza orizz. (contr. nucleo in piombo) Horizontal stiffness (lead core contribution) Fy Carico di snervamento del nucleo Yield point load for lead core Keff Rigidezza orizzontale efficace Effective horizontal stiffness Smax Spostamento di progetto | Design displacement LRS Dati geometrici | Geometrical Data te Spessore elastomero Thickness of the elastomer H Altezza totale isolatore Overall height of the isolator D Diametro elastomero Diameter of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B βeff = 28% per tutti gli isolatori for all isolators Vmax Vsism Kr Klead Fy Keff [kN] [kN] [kN/mm] [kN/mm] [kN] [kN/mm] LRN Vmax Vsism Kr Klead Fy Keff H te Smax [kN] [kN] [kN/mm] [kN/mm] [%] [kN/mm] [mm] [mm] [mm] Diametro elastomero / Elastomer diameter D = 500 LRS500X50 LRS500X60 LRS500X70 LRS500X80 LRS500X90 1700 1950 2150 2250 2350 1700 1950 2150 2000 1650 1,52 1,27 1,09 0,95 0,84 16,54 13,78 11,81 10,34 9,19 69 69 69 69 69 2,16 1,80 1,54 1,35 1,20 LRN500X50 LRN500X60 LRN500X70 LRN500X80 LRN500X90 3350 3800 4150 4350 4500 3350 3500 4150 3850 3250 3,17 2,64 2,27 1,98 1,76 52,28 43,56 37,34 32,67 29,04 213 213 213 213 213 5,18 4,32 3,70 3,24 2,88 160 175 196 212 228 50 60 70 80 90 100 120 140 160 180 LRS500X100 LRS500X110 LRS500X120 LRS500X130 LRS500X140 LRS500X150 LRS500X160 LRS500X170 2400 2150 1950 1800 1600 1500 1350 1250 1400 1200 1050 900 800 700 600 500 0,76 0,69 0,63 0,58 0,54 0,51 0,47 0,45 8,27 7,52 6,89 6,36 5,91 5,51 5,17 4,86 69 69 69 69 69 69 69 69 1,08 0,98 0,90 0,83 0,77 0,72 0,67 0,63 LRN500X100 LRN500X110 LRN500X120 LRN500X130 LRN500X140 LRN500X150 LRN500X160 LRN500X170 4600 4200 3800 3450 3150 2900 2650 2450 2750 2350 2050 1750 1550 1350 1200 1050 1,59 1,44 1,32 1,22 1,13 1,06 0,99 0,93 26,14 23,76 21,78 20,11 18,67 17,43 16,34 15,38 213 213 213 213 213 213 213 213 2,59 2,36 2,16 1,99 1,85 1,73 1,62 1,52 244 260 276 280 295 310 310 324 100 110 120 130 140 150 160 170 200 220 240 260 280 300 320 340 3,37 2,87 2,48 2,17 1,93 1,74 1,58 1,45 1,34 1,24 1,16 74,26 52,95 42,96 37,59 33,42 30,07 27,34 25,06 23,13 21,48 20,05 328 283 269 269 269 269 269 269 269 269 269 6,23 4,79 4,07 3,58 3,20 2,89 2,60 2,39 2,21 2,06 1,93 165 181 203 220 245 263 281 288 305 309 325 55 66 77 88 99 110 121 132 143 154 165 110 140 160 180 200 220 250 270 290 310 330 3,79 3,16 2,71 2,37 2,11 1,90 1,72 1,58 1,46 1,35 1,26 1,19 1,12 64,71 53,92 46,22 40,44 35,95 32,35 29,41 26,96 24,89 23,11 21,57 20,22 19,03 316 316 316 316 316 316 316 316 316 316 316 316 316 6,28 5,15 4,47 3,86 3,46 3,14 2,83 2,61 2,39 2,23 2,09 1,95 1,84 170 192 216 235 254 282 292 311 318 336 340 357 374 60 72 84 96 108 120 132 144 156 168 180 192 204 120 150 170 200 220 240 270 290 320 340 360 390 410 4,12 3,43 69,27 57,73 367 367 6,78 5,59 179 198 65 78 130 160 Diametro elastomero / Elastomer diameter D = 550 LRS550X55 LRS550X66 LRS550X77 LRS550X88 LRS550X99 LRS550X110 LRS550X121 LRS550X132 LRS550X143 LRS550X154 LRS550X165 2100 2350 2600 2700 2800 2900 2650 2400 2150 2000 1800 2100 2350 2600 2400 2050 1750 1400 1250 1100 950 850 1,67 1,39 1,19 1,04 0,93 0,84 0,76 0,70 0,64 0,60 0,56 18,56 15,47 13,26 11,60 10,31 9,28 8,44 7,73 7,14 6,63 6,19 86 86 86 86 86 86 86 86 86 86 86 2,38 1,95 1,68 1,48 1,32 1,19 1,07 0,99 0,91 0,85 0,79 LRN550X55 LRN550X66 LRN550X77 LRN550X88 LRN550X99 LRN550X110 LRN550X121 LRN550X132 LRN550X143 LRN550X154 LRN550X165 3750 4450 4950 5200 5400 5550 5050 4550 4150 3800 3500 3750 4450 4950 4600 3900 3350 2800 2450 2150 1850 1650 Diametro elastomero / Elastomer diameter D = 600 LRS600X60 LRS600X72 LRS600X84 LRS600X96 LRS600X108 LRS600X120 LRS600X132 LRS600X144 LRS600X156 LRS600X168 LRS600X180 LRS600X192 LRS600X204 2450 2850 3100 3250 3350 3500 3150 2900 2600 2350 2200 2000 1850 2450 2850 3100 2850 2450 2100 1750 1550 1300 1150 1050 850 800 1,83 1,52 1,30 1,14 1,01 0,91 0,83 0,76 0,70 0,65 0,61 0,57 0,54 18,76 17,16 14,71 12,87 11,44 9,38 9,36 7,82 7,92 7,35 6,25 6,43 5,52 95 103 103 103 103 95 103 95 103 103 95 103 95 2,55 2,15 1,86 1,61 1,44 1,27 1,18 1,06 1,00 0,93 0,85 0,81 0,75 LRN600X60 LRN600X72 LRN600X84 LRN600X96 LRN600X108 LRN600X120 LRN600X132 LRN600X144 LRN600X156 LRN600X168 LRN600X180 LRN600X192 LRN600X204 4800 5450 5950 6250 6500 6650 6100 5500 5000 4550 4200 3850 3600 4800 5450 5950 5500 4700 4000 3400 2950 2550 2250 2000 1700 1500 Diametro elastomero / Elastomer diameter D = 650 LRS650X65 LRS650X78 2950 3350 2950 3350 1,98 1,64 20,77 18,85 114 123 2,78 LRN650X65 2,35 LRN650X78 18 5650 6450 5650 6450 Legenda | Legend LRS LRS ξr= 10% - G = 0,4 MPa LRN LRN ξr= 4% - G = 0,9 MPa ξr Smorzamento viscoso della gomma Viscous damping of the rubber βeff Smorzamento efficace | Effective damping Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale (contributo elastomero) Horizontal stiffness (elastomer contribution) Klead Rigidezza orizz. (contr. nucleo in piombo) Horizontal stiffness (lead core contribution) Fy Carico di snervamento del nucleo Yield point load for lead core Keff Rigidezza orizzontale efficace Effective horizontal stiffness Smax Spostamento di progetto | Design displacement LRS Dati geometrici | Geometrical Data te Spessore elastomero Thickness of the elastomer H Altezza totale isolatore Overall height of the isolator D Diametro elastomero Diameter of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B βeff = 28% per tutti gli isolatori for all isolators Vmax Vsism Kr Klead Fy Keff [kN] [kN] [kN/mm] [kN/mm] [kN] [kN/mm] LRN Vmax Vsism Kr Klead Fy Keff H te Smax [kN] [kN] [kN/mm] [kN/mm] [%] [kN/mm] [mm] [mm] [mm] Diametro elastomero / Elastomer diameter D = 650 LRS650X91 3600 3600 1,41 16,16 123 2,00 LRN650X91 6900 6900 2,92 51,86 384 4,83 223 91 190 LRS650X104 LRS650X117 LRS650X130 LRS650X143 LRS650X156 LRS650X169 LRS650X182 LRS650X195 LRS650X208 3850 3950 4100 3750 3350 3100 2800 2600 2400 3450 2850 2500 2100 1800 1500 1350 1200 1050 1,24 1,10 0,99 0,90 0,82 0,76 0,71 0,66 0,62 12,98 12,57 10,39 9,44 9,42 7,99 7,42 6,92 6,49 114 123 114 114 123 114 114 114 114 1,73 1,57 1,39 1,26 1,18 1,07 0,99 0,93 0,87 7400 7550 7800 7150 6450 5950 5350 5000 4600 6600 5450 4700 4000 3450 3050 2600 2350 2050 2,57 2,27 2,05 1,86 1,70 1,58 1,46 1,37 1,29 43,30 40,34 36,31 33,00 30,25 26,64 25,93 23,09 21,65 367 384 384 384 384 367 384 367 367 4,22 3,79 3,44 3,11 2,84 2,60 2,44 2,26 2,11 250 271 292 313 323 343 350 369 373 104 117 130 143 156 169 182 195 208 210 240 260 290 320 340 370 390 420 4,41 3,68 3,15 2,76 2,45 2,21 2,01 1,84 1,70 1,58 1,47 77,16 64,30 55,11 48,22 42,87 38,58 35,07 32,15 29,68 27,56 25,72 439 439 439 439 439 439 439 439 439 439 439 7,38 6,12 5,23 4,57 4,05 3,69 3,35 3,06 2,82 2,62 2,46 184 209 236 258 280 311 324 346 356 377 384 70 84 98 112 126 140 154 168 182 196 210 140 170 200 230 260 280 310 340 370 400 420 4,74 3,95 3,38 2,96 2,63 2,37 2,15 1,97 1,82 1,69 81,72 68,10 58,37 51,07 45,40 40,86 37,14 34,05 31,43 29,18 499 499 499 499 499 499 499 499 499 499 7,88 6,57 5,63 4,92 4,38 3,94 3,58 3,28 3,03 2,81 189 215 243 273 297 321 345 358 381 391 75 90 105 120 135 150 165 180 195 210 150 180 210 240 270 300 330 360 390 420 5,06 4,21 3,61 3,16 2,81 2,53 2,29 1,95 86,28 71,90 61,63 53,92 47,93 43,14 40,74 33,18 562 562 562 562 562 562 583 562 8,38 6,87 5,92 5,20 4,64 4,19 3,82 3,21 218 246 276 301 334 360 376 414 80 96 112 128 144 160 176 208 160 200 230 260 290 320 360 420 LRN650X104 LRN650X117 LRN650X130 LRN650X143 LRN650X156 LRN650X169 LRN650X182 LRN650X195 LRN650X208 Diametro elastomero / Elastomer diameter D = 700 LRS700X70 LRS700X84 LRS700X98 LRS700X112 LRS700X126 LRS700X140 LRS700X154 LRS700X168 LRS700X182 LRS700X196 LRS700X210 3450 3950 4250 4450 4600 4750 4400 3950 3600 3300 3000 3450 3950 4250 4000 3350 2900 2450 2150 1850 1600 1400 2,13 1,77 1,52 1,33 1,18 1,06 0,97 0,89 0,82 0,76 0,71 22,79 18,99 16,28 14,24 12,66 11,40 10,36 9,50 8,77 8,14 7,60 134 134 134 134 134 134 134 134 134 134 134 3,01 2,50 2,13 1,86 1,65 1,50 1,36 1,25 1,15 1,07 1,00 LRN700X70 LRN700X84 LRN700X98 LRN700X112 LRN700X126 LRN700X140 LRN700X154 LRN700X168 LRN700X182 LRN700X196 LRN700X210 6550 7500 8100 8550 8800 9100 8350 7550 6850 6250 5750 6550 7500 8100 7600 6350 5500 4700 4050 3500 3050 2700 Diametro elastomero / Elastomer diameter D = 750 LRS750X75 LRS750X90 LRS750X105 LRS750X120 LRS750X135 LRS750X150 LRS750X165 LRS750X180 LRS750X195 LRS750X210 3950 4550 4900 5200 5350 5100 5000 4550 4150 3800 3950 4550 4900 4600 3900 3350 2850 2500 2150 1900 2,28 1,90 1,63 1,42 1,27 1,14 1,04 0,95 0,88 0,81 24,81 20,68 17,72 15,51 13,78 12,41 11,28 10,34 9,54 8,86 156 156 156 156 156 156 156 156 156 156 3,23 2,70 2,31 2,02 1,80 1,62 1,47 1,35 1,24 1,16 LRN750X75 LRN750X90 LRN750X105 LRN750X120 LRN750X135 LRN750X150 LRN750X165 LRN750X180 LRN750X195 LRN750X210 7550 8650 9400 9900 10250 10500 9700 8750 7950 7250 7550 8650 9400 8900 7500 6400 5500 4750 4150 3600 Diametro elastomero / Elastomer diameter D = 800 LRS800X80 LRS800X96 LRS800X112 LRS800X128 LRS800X144 LRS800X160 LRS800X176 LRS800X208 4450 5100 5550 5900 6100 6250 5700 4750 4450 5100 5550 5250 4450 3800 3250 2450 2,43 2,03 1,74 1,52 1,35 1,22 1,10 0,93 26,83 22,36 19,17 16,77 14,91 13,42 12,20 10,32 180 180 180 180 180 180 180 180 3,46 2,85 2,45 2,15 1,92 1,73 1,56 1,33 LRN800X80 LRN800X96 LRN800X112 LRN800X128 LRN800X144 LRN800X160 LRN800X176 LRN800X208 19 8600 9800 10700 11300 11700 12000 10950 9100 8600 9800 10700 10100 8550 7300 6150 4700 Legenda | Legend LRS LRS ξr= 10% - G = 0,4 MPa LRN LRN ξr= 4% - G = 0,9 MPa ξr Smorzamento viscoso della gomma Viscous damping of the rubber βeff Smorzamento efficace | Effective damping Dati tecnici | Technical Data Vmax Carico verticale massimo allo SLU con spostamento nullo Max vertical load at ULS (Ultimate Limit State) with zero displacement Vsism Carico verticale in condizione sismica Vertical load under seismic conditions Kr Rigidezza orizzontale (contributo elastomero) Horizontal stiffness (elastomer contribution) Klead Rigidezza orizz. (contr. nucleo in piombo) Horizontal stiffness (lead core contribution) Fy Carico di snervamento del nucleo Yield point load for lead core Keff Rigidezza orizzontale efficace Effective horizontal stiffness Smax Spostamento di progetto | Design displacement LRS Dati geometrici | Geometrical Data te Spessore elastomero Thickness of the elastomer H Altezza totale isolatore Overall height of the isolator D Diametro elastomero Diameter of the elastomer B Dimensione d’ingombro dell’isolatore (nelle due direzioni) Overall dimensions (space requirement) of the isolator (in two directions) Z Interasse degli ancoraggi (nelle due direzioni) Distance between centers of anchorages (in two directions) B = D + 50 Z = 0,75 x B βeff = 28% per tutti gli isolatori for all isolators Vmax Vsism Kr Klead Fy Keff [kN] [kN] [kN/mm] [kN/mm] [kN] [kN/mm] LRN Vmax Vsism Kr Klead Fy Keff H te Smax [kN] [kN] [kN/mm] [kN/mm] [%] [kN/mm] [mm] [mm] [mm] 5,68 4,73 4,06 3,55 3,15 2,84 2,58 2,37 98,73 82,27 70,52 61,70 54,85 49,36 44,88 41,14 723 723 723 723 723 723 723 723 9,48 7,84 6,68 5,91 5,23 4,74 4,29 3,92 232 263 296 324 360 389 418 436 90 108 126 144 162 180 198 216 180 220 260 290 330 360 400 440 107,84 89,87 77,03 67,40 59,91 53,92 49,02 44,94 878 878 878 878 878 878 878 878 10,47 8,72 7,48 6,54 5,82 5,23 4,76 4,36 262 300 336 367 406 438 470 491 100 120 140 160 180 200 220 240 200 240 280 320 360 400 440 480 120,29 100,25 85,92 75,18 66,83 60,15 54,68 1077 1077 1077 1077 1077 1077 1077 11,57 9,56 8,24 7,17 6,40 5,78 5,23 276 317 356 390 432 476 502 110 132 154 176 198 220 242 220 270 310 360 400 440 490 129,41 110,63 94,82 82,97 73,75 64,71 60,34 1265 1295 1295 1295 1295 1265 1295 12,56 10,53 9,01 7,87 6,99 6,28 5,75 290 334 376 420 458 505 534 120 144 168 192 216 240 264 240 290 340 390 440 480 530 1757 1757 110,23 1757 96,45 1757 85,73 1757 14,76 12,24 10,46 9,21 8,16 318 363 416 466 518 140 168 196 224 252 280 340 400 450 510 Diametro elastomero / Elastomer diameter D = 900 LRS900X90 LRS900X108 LRS900X126 LRS900X144 LRS900X162 LRS900X180 LRS900X198 LRS900X216 5700 6550 7100 7500 7750 8000 7400 6650 5700 6550 7100 6750 5650 4850 4150 3600 2,74 2,28 1,96 1,71 1,52 1,37 1,24 1,14 29,04 24,20 20,74 18,15 16,13 14,52 13,20 12,10 220 220 220 220 220 220 220 220 3,86 3,20 2,73 2,40 2,13 1,93 1,75 1,60 LRN900X90 LRN900X108 LRN900X126 LRN900X144 LRN900X162 LRN900X180 LRN900X198 LRN900X216 10900 12450 13500 14350 14800 15200 14050 12700 10900 12450 13500 12900 10800 9300 7950 6850 Diametro elastomero / Elastomer diameter D = 1000 LRS1000X100 LRS1000X120 LRS1000X140 LRS1000X160 LRS1000X180 LRS1000X200 LRS1000X220 LRS1000X240 7050 8100 8850 9300 9650 9850 9150 8250 7050 8100 8850 8400 7100 6050 5200 4500 3,04 2,53 2,17 1,90 1,69 1,52 1,38 1,27 33,08 27,57 23,63 20,68 18,38 16,54 15,04 13,78 278 278 278 278 278 278 278 278 4,31 3,59 3,08 2,70 2,40 2,16 1,96 1,80 LRN1000X100 LRN1000X120 LRN1000X140 LRN1000X160 LRN1000X180 LRN1000X200 LRN1000X220 LRN1000X240 13550 15550 16950 17850 18500 18900 17550 15850 13550 15550 16950 16100 13600 11600 10000 8650 6,32 5,27 4,52 3,95 3,51 3,16 2,87 2,63 Diametro elastomero / Elastomer diameter D = 1100 LRS1100X110 LRS1100X132 LRS1100X154 LRS1100X176 LRS1100X198 LRS1100X220 LRS1100X242 8550 9750 10650 11200 11650 11950 11000 8550 9750 10650 10100 8550 7350 6250 3,34 2,78 2,39 2,09 1,86 1,67 1,52 37,13 30,94 26,52 23,20 20,63 18,56 16,88 342 342 342 342 342 342 342 4,77 3,95 3,40 2,96 2,64 2,38 2,16 LRN1100X110 LRN1100X132 LRN1100X154 LRN1100X176 LRN1100X198 LRN1100X220 LRN1100X242 16350 18700 20450 21450 22300 22900 21250 16350 18700 20450 19350 16400 14050 12000 6,94 5,79 4,96 4,34 3,86 3,47 3,16 Diametro elastomero / Elastomer diameter D = 1200 LRS1200X120 LRS1200X144 LRS1200X168 LRS1200X192 LRS1200X216 LRS1200X240 LRS1200X264 10200 11700 12750 13400 13900 14300 13300 10200 11700 12750 12150 10200 8800 7550 3,65 3,04 2,61 2,28 2,03 1,82 1,66 39,33 32,78 28,09 24,58 21,85 19,67 17,88 397 397 397 397 397 397 397 5,16 4,29 3,67 3,21 2,85 2,58 2,34 LRN1200X120 LRN1200X144 LRN1200X168 LRN1200X192 LRN1200X216 LRN1200X240 LRN1200X264 19550 22350 24250 25550 26450 27400 25350 19550 22350 24250 25550 19450 16850 14400 7,59 6,30 5,40 4,73 4,20 3,79 3,44 Diametro elastomero / Elastomer diameter D = 1400 LSR1400X140 LSR1400X168 LSR1400X196 LSR1400X224 LSR1400X252 13900 15950 17300 18350 18950 13900 15950 17300 16650 14000 4,26 3,54 3,04 2,66 2,36 45,58 39,52 33,87 29,64 26,35 537 556 556 556 556 6,01 5,05 4,31 3,79 3,36 LRN1400X140 LRN1400X168 LRN1400X196 LRN1400X224 LRN1400X252 20 26500 30500 33100 35050 36250 26500 30500 33100 31800 26750 8,83 7,36 6,31 5,52 4,90 154,32 128,60 Ospedale di Frosinone, isolato sismicamente con HDRB (Italia, 2006) Frosisnone’s Hospital, isolated with HDRB (Italy, 2006) Prove di laboratorio Laboratory Tests ALGASISM’s HDRB and LRB isolators are subjected to rigorous quality controls, as listed in the following table. The tests are divided into: • Prototype tests performed by ALGA for the definition of the technical characteristics; • Production tests, which are performed on 20% of the isolators produced in order to verify their correspondence to project characteristics (some norm require different test frequencies: for example, AASHTO requires 100%). Gli isolatori ALGASISM HDRB e LRB sono soggetti a rigorosi controlli di qualità che comprendono le prove di laboratorio elencate nella tabella seguente (conformi alla EN15129). Le prove si dividono in: • Prove prototipali che vengono effettuate a cura di ALGA per la definizione delle caratteristiche tecniche degli isolatori • Prove di produzione che vengono effettuate su di una percentuale del 20% degli isolatori prodotti per verificarne la rispondenza alle caratteristiche di progetto (alcune normative prevedono una frequenza diversa di prove: la AASHTO ad esempio il 100%) Prototipo Type test Prova / Test Produzione / Factory production control Compressione a spostamento zero / Compression at zero displacement X Rigidezza Kr / Stiffness Kr X 20% Kr e ξr per deformazione ciclica / Kr and ξr for cyclic deformation X 20% K per carico incrementale / K for incremental load X 20% Variazione di Kr e ξr con la frequenza / Variation of Kr and ξr with frequency X Variazione di Kr e ξr con la temperatura / Variation of Kr and ξr with temperature X Variazione di Kr e ξr con carichi ciclici / Variation of Kr and ξr with cyclic loads X Deformazione orizz. con Vmin e max / Horizontal deformation with Vmin and max X Variazione di Kr e ξr con l’invecchiamento / Variation of Kr and ξr over time X Deformazione viscosa con carico vert. / Viscous deformation with vertical load X Resistenza al fuoco Fire resistance Se è necessario garantire la resistenza al fuoco gli isolatori ALGASISM HDRB e LRB possono essere protetti da speciali pannelli fino a raggiungere la durata prevista. If necessary the ALGASISM HDRB and LRB can be protected from the fire by the application of special fire resistant panels. Manutenzione Maintenance Normativa di riferimento Reference Norms ALGASISM HDRB and LRB isolators do not require any special maintenance. An inspection is recommended however at least once every 5 years or after an exceptional event such as earthquake, flood, or fire. A lateral deformation of an isolator that shows the internal stratification is perfectly normal. If there are irregular deformations, these must be brought to the attention of an expert. If necessary, the anti-corrosion protection for the external metallic plates shall be restored. Gli isolatori ALGASISM HDRB e LRB non necessitano di particolare manutenzione. Si raccomanda tuttavia un’ispezione almeno ogni 5 anni o dopo un evento eccezionale come terremoto, allagamento o incendio. Una deformazione laterale dell’isolatore che ne evidenzi la stratificazione interna è perfettamente normale. Eventuali deformazioni irregolari richiedono di riportare il fenomeno ad un esperto. Se necessario occorre ripristinare la protezione anticorrosiva delle piastre metalliche esterne. ALGA’s HDRB and LRB isolators respond principally to EN15129. The HDRB and LRB isolators produced by ALGA can also be made according to other norms, such as AASHTO or ISO 22762. Gli HDRB e LRB prodotti da ALGA rispondono alla EN15129. Gli HDRB e LRB prodotti da ALGA possono anche essere resi conformi su richiesta ad altre normative come le AASHTO o le ISO 22762. 21 Posa in opera Di seguito i principali passi per i casi più frequenti: 1. Getto delle infrastrutture fino a quota inferiore di qualche centimetro alla quota finale degli isolatori. Occorre lasciare nel getto dei tubi (ad esempio di lamierino corrugato) nella posizione delle zanche e di diametro almeno doppio delle stesse 1 2. Posizionamento degli isolatori alla giusta quota con l’aiuto di cunei o delle viti di regolazione e casseratura dell’area circostante l’isolatore 3. Getto del giunto in malta reoplastica o epossidica. Il giunto di malta non dev’essere armato se il suo spessore è minore o uguale dei seguenti valori: • 50 mm oppure: area - piastre - metalliche • 0,1x ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ + 15mm perimetro - piastre - metalliche 2 4. Casseratura della sovrastruttura e sua sigillatura attorno all’isolatore 5. Getto delle sovrastrutture Per maggiori dettagli si può vedere la EN 1337-11 Installation The principal steps for the most frequent cases: 3 1. Casting of the infrastructure up to a level a few centimeters lower than the final level of the isolators. Tubes (for example corrugated steel sheets) of double diameter than the anchors shall be left in the concrete at the positions of the anchor brackets; 2. Positioning of the isolators at the proper level with the aid of wedges or regulating screws and placing of a formwork surrounding the isolator; 3. Casting of the joint in the non-shrink mortar or epoxy mortar. The mortar joint shall not be reinforced if its thickness is less or equal to the following values: 4 • 50 mm or area - metallic - plates • 0,1x ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ + 15mm perimeter - metallic - plates 4. Placing of the formwork of the superstructure and sealing it around the isolator. 5. Casting of the superstructure. For further details, please see EN 1337-11. 5 22 Dispositivi antisismici Antiseismic devices HDRB Appoggi in gomma ad alta dissipazione di energia High Damping Rubber Bearings LRB Appoggi in piombo-elastomero Lead Rubber Bearings PND | PNDU Isolatori isteretici con appoggio a disco elastomerico Hysteretic Isolators with pot bearings CSD | CSDU Isolatori isteretici con appoggio a calotta sferica Hysteretic isolators with spherical bearing EP Ammortizzatori isteretici Hysteretic Dampers ED Ammortizzatori elastici Elastic Dampers AlgaPEND Isolatori a pendolo scorrevole Sliding Pendulum Isolators Giunti di dilatazione Expansion joints Sistemi di postensione Post tensioning system AlgaFLEX TX Giunti stradali elastomerici Road Rubber Mat Joints AlgaCABLE Sistema di postensione a trefoli Strands Post-tensioning system AlgaFLEX TM Giunti stradali elastomerici per grandi escursioni fino a 800 mm Road Rubber Mat Joints for large displacements up to 800 mm movement AlgaBAR Sistema di postensione a barre Bars post-tensioning system AlgaFLEX TW Giunti ferroviari fino a 350 mm di escursione Railway joints up to 350 mm movement PT SLAB Soluzione per solai postesi Postensioned slabs AlgaSTAY Stralli | Stay cables AlgaMOD LW Giunti modulari a lamelle in acciaio fino a 2000 mm di escursione e oltre Steel profile Modular Joints up to 2000 mm movement and more Appoggi Bearings ALGAPOT Appoggi a disco elastomerico Pot bearings AlgaFLON Appoggi in gomma armata e PTFE Elastomeric Bearings with PTFE AlgaBLOC Appoggi in gomma armata Elastomeric Bearings SFERON Appoggi sferici Spherical Bearings FSK | MSK Chiavi di taglio fisse e mobili Fixed and Movable Shear Keys Alga R Giunti a piastre articolate fino a 2000 mm di escursione e oltre Roller Shutter Joints up to 2000 mm movement and more DECS Ammortizzatori elettroinduttivi Electro Inductive Dampers Ripristini strutturali Structural repair STU Accoppiatori Idraulici Shock Transmission Units Adeguamento sismico mediante l’inserimento di isolatori o altri dispositivi antisismici Rinforzi strutturali e adeguamenti sismici con fibre di carbonio Sollevamento dal basso o dall’alto di campate di ponti e viadotti Sostituzione dei vincoli strutturali Trasferimenti di carico Aggiunta o rimozione di elementi portanti Spostamenti di interi manufatti Regolazione dei carichi presenti Monitoraggio di carichi e spostamenti Metodi di costruzione innovativi Aggiunta di precompressione esterna Ripristino di calcestruzzi ammalorati mediante metodi meccanici o elettrochimici FD Ammortizzatori Viscosi Viscous Dampers VED Ammortizzatori Viscoelastici Visco-Elastic Dampers I dati tecnici inclusi nel presente catalogo sono indicativi e possono essere variati da Alga senza preavviso. All technical data in this cathalog are indicative and may be changed by Alga without any notice. Lifting of bridge spans from top or bottom Replacement of the structural bearings Load transfers Installing or removing structural components Adjustment of the bearing reactions Monitoring of loads and displacement Innovative construction methods Application of external posttensioning Seismic retrofitting by use of isolators or other antiseismic devices Repair of damaged concrete by mechanical or electro-chemical means Alga S.p.A. - Sede e Direzione - Main office: Via Dei Missaglia 97/A2 - 20142 Milano - www.alga.it - [email protected] - tel. +39 02.48569.1 - fax. +39 02.48569.245