fusibili e portafusibili
norme ul/Csa
173
Fusibili classi K5 / H / RK5 - Tensione nominale 250V
Classes K5 / H / RK5 fuses - Rated voltage 250V
174
Fusibili classi K5 / H / RK5 - Tensione nominale 600V
Classes K5 / H / RK5 fuses - Rated voltage 600V
175
Fusibili classe Supplemental - Tensione nominale 250V e 600V
Class Supplemental fuses - Rated voltage 250V and 600V
176
Fusibili classe CC - Tensione nominale 600V
Class CC fuses - Rated voltage 600V
177
Fusibili classe J - Tensione nominale 600V
Class J fuses - Rated voltage 600V
178
Fusibili classe RK1 - Tensione nominale 250V e 600V
Class RK1 fuses - Rated voltage 250V and 600V
180
Fusibili classe T - Tensione nominale 300V e 600V
Class T fuses - Rated voltage 300V and 600V
180
Fusibili tipo KLM e DMM-B
Type KLM and DMM-B fuses
181
Fusibili extrarapidi fissaggio a bullone
High speed screw fixing fuses
182
Basi portafusibili e accessori
Fuse bases and accessories
184
Dimensioni e caratteristiche tecniche
Dimensions and technical specifications
188
ITALWEBER
ul / csa
UL/CSA standards
norme UL/CSA
FuSeS anD FuSeHoLDeRS
uL/CSa STanDaRDS
fusibili omologati per il nord-ameriCa
Classi “k5”-“h”-“rk5” a 250V
noRTH-aMeRiCa appRoVeD FuSeS
CLaSSeS “K5”-”H”-”RK5” aT 250V
Norme - Standards UL 248-6, UL 248-9, UL 248-12, CSA C22.2
I fusibili rapidi delle serie NON appartengono alle classi di fusibili UL/CSA denominati K5 e H. Tali classi definiscono fusibili per uso generale, non limitatori di corrente e con potere di interruzione relativamente basso (10kA o 50kA). Essi sono utilizzati per la protezione dai sovraccarichi e dai corto circuiti di tutti gli utilizzatori
classici (cavi, circuiti di illuminazione, ecc.). I fusibili della serie FRN-R appartengono
alla classe RK5. Si tratta di fusibili ritardati di tipo limitatore di corrente, e con
potere di interruzione di 200kA. Essi vengono utilizzati per la protezione dal corto
circuito di motori e apparecchiature che presentano uno spunto di corrente all’avvio.
The fast-acting fuses of the series non belong to the uL/CSa fuses classes
called K5 and H. These classes define fuses for general purpose, non current
limiting and with relatively low breaking capacity (10ka or 50ka). They can
be used for protection against overloads and short-circuits for cables, lighting
circuits, etc. The fuses of the series FRn-R belong to the class RK5. They are
fuses with a time-delay characteristic, they are current limiting fuses and have
a breaking capacity equal to 200ka. They are normally used for short-circuit
protection of motors and equipments that present a current peak at startup.
fusibili a standard ul-Csa - serie f rapidi e t ritardati a 250V, Con omologazioni
SeRieS F FaST-aCTing anD T TiMe-DeLay 250V FuSeS, aCCoRDing To uL/CSa STanDaRDS
app
appRoVeD
tipo
type
Fusibile NON-60
non-60 fuse
UL-14
14x51
Fusibile FRN-R-40
UL-20
21x76
FRn-R-40 fuse
UL-27
27x149
UL-40
40x181
UL-53
53x219
Fusibile FRN-R-80
FRn-R-80 fuse
174
UL-66
66x264
serie F rapidi
F series fast-acting fuses
codice IW descrizione classe
IW code
description class
serie T ritardati
T series time-delay fuses
codice IW descrizione classe
IW code
description class
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
1801000
1801001
1801002
1801003
1801004
1801005
1801006
1801007
1801008
1801009
1801010
1801012
1801015
1801020
1801025
1801030
1801135
1801140
1801145
1801150
1801160
1801270
1801275
1801280
1801290
1801299
1801310
1801325
1801350
1801375
1801399
1801425
1801450
1801500
1801550
1801599
1801650
1801660
1801670
1802000
1802001
1802002
1802003
1802004
1802005
1802006
1802007
1802008
1802009
1802010
1802012
1802015
1802020
1802025
1802030
1802135
1802140
1802145
1802150
1802160
1802270
1802275
1802280
1802290
1802299
1802310
1802325
1802350
1802375
1802399
1802425
1802450
1802500
1802550
1802599
1802650
1802660
1802670
0,5A
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
15A
20A
25A
30A
35A
40A
45A
50A
60A
70A
75A
80A
90A
100A
110A
125A
150A
175A
200A
225A
250A
300A
350A
400A
450A
500A
600A
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-5
1-5
1-5
1-5
1-5
1
1
1
1
1
1
1
1
1
1
1
1
1
NON-1/2
NON-1
NON-2
NON-3
NON-4
NON-5
NON-6
NON-7
NON-8
NON-9
NON-10
NON-12
NON-15
NON-20
NON-25
NON-30
NON-35
NON-40
NON-45
NON-50
NON-60
NON-70
NON-75
NON-80
NON-90
NON-100
NON-110
NON-125
NON-150
NON-175
NON-200
NON-225
NON-250
NON-300
NON-350
NON-400
NON-450
NON-500
NON-600
Dimensioni: pagina 188 - Caratteristiche tecniche: pagine 188-189
Dimensions: page 188 - Technical specifications: pages 188-189
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
FRN-R-1/2
FRN-R-1
FRN-R-2
FRN-R-3
FRN-R-4
FRN-R-5
FRN-R-6
FRN-R-7
FRN-R-8
FRN-R-9
FRN-R-10
FRN-R-12
FRN-R-15
FRN-R-20
FRN-R-25
FRN-R-30
FRN-R-35
FRN-R-40
FRN-R-45
FRN-R-50
FRN-R-60
FRN-R-70
FRN-R-75
FRN-R-80
FRN-R-90
FRN-R-100
FRN-R-110
FRN-R-125
FRN-R-150
FRN-R-175
FRN-R-200
FRN-R-225
FRN-R-250
FRN-R-300
FRN-R-350
FRN-R-400
FRN-R-450
FRN-R-500
FRN-R-600
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
ITALWEBER
fusibili omologati per il nord-ameriCa
Classi “k5”-“h”-“rk5” a 600V
noRTH-aMeRiCa appRoVeD FuSeS
CLaSSeS “K5”-”H”-”RK5” aT 600V
Norme - Standards UL 248-6, UL 248-9, UL 248-12, CSA C22.2
I fusibili rapidi delle serie NOS appartengono alle classi di fusibili a standard UL/CSA
denominati K5 e H. Tali classi definiscono fusibili per uso generale, non limitatori di
corrente e con potere di interruzione relativamente basso (10kA o 50kA). Essi sono
utilizzati per la protezione dai sovraccarichi e dai corto circuiti di tutti gli utilizzatori
classici (cavi, circuiti di illuminazione, ecc.). I fusibili della serie FRS-R appartengono
alla classe RK5. Si tratta di fusibili ritardati di tipo limitatore di corrente, e con
potere di interruzione di 200kA. Essi vengono utilizzati per la protezione dal corto
circuito di motori e apparecchiature che presentano uno spunto di corrente all’avvio.
The fast-acting fuses of the series noS belong to the uL/CSa fuses classes
called K5 and H. These classes define fuses for general purpose, non current
limiting and with relatively low breaking capacity (10ka or 50ka). They can
be used for protection against overloads and short-circuits for cables, lighting
circuits, etc. The fuses of the series FRS-R belong to the class RK5. They are
fuses with a time-delay characteristic, they are current limiting fuses and have
a breaking capacity equal to 200ka. They are normally used for short-circuit
protection of motors and equipments that present a current peak at startup.
tipo
type
Fusibile NOS-30
noS-30 fuse
UL-20
21x127
UL-27
27x139
Fusibile FRS-R-125
FRS-R-125 fuse
UL-34
34x200
UL-46
46x244
UL-66
66x295
Fusibile NOS-350
noS-350 fuse
175
UL-80
80x340
serie F rapidi
F series fast-acting fuses
codice IW descrizione classe
IW code
description class
serie T ritardati
T series time-delay fuses
codice IW descrizione classe
IW code
description class
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
–
1803001
1803002
1803003
1803004
1803005
1803006
1803007
1803008
1803009
1803010
1803012
1803015
1803020
1803025
1803030
1803135
1803140
1803145
1803150
1803160
1803270
1803275
1803280
1803290
1803299
1803310
1803325
1803350
1803375
1803399
1803425
1803450
1803500
1803550
1803599
1803650
1803660
1803670
1804000
1804001
1804002
1804003
1804004
1804005
1804006
1804007
1804008
1804009
1804010
1804012
1804015
1804020
1804025
1804030
1804135
1804140
1804145
1804150
1804160
1804270
1804275
1804280
1804290
1804299
1804310
1804325
1804350
1804375
1804399
1804425
1804450
1804500
1804550
1804599
1804650
1804660
1804670
0,5A
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
15A
20A
25A
30A
35A
40A
45A
50A
60A
70A
75A
80A
90A
100A
110A
125A
150A
175A
200A
225A
250A
300A
350A
400A
450A
500A
600A
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-5
1-5
1-5
1-5
1-5
1-5
1-5
1-5
1-5
1-5
1
1
1
1
1
1
1
1
1
1
1
1
1
–
NOS-1
NOS-2
NOS-3
NOS-4
NOS-5
NOS-6
NOS-7
NOS-8
NOS-9
NOS-10
NOS-12
NOS-15
NOS-20
NOS-25
NOS-30
NOS-35
NOS-40
NOS-45
NOS-50
NOS-60
NOS-70
NOS-75
NOS-80
NOS-90
NOS-100
NOS-110
NOS-125
NOS-150
NOS-175
NOS-200
NOS-225
NOS-250
NOS-300
NOS-350
NOS-400
NOS-450
NOS-500
NOS-600
Dimensioni: pagina 188 - Caratteristiche tecniche: pagine 188-189
Dimensions: page 188 - Technical specifications: pages 188-189
–
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
K5
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
FRS-R-1/2
FRS-R-1
FRS-R-2
FRS-R-3
FRS-R-4
FRS-R-5
FRS-R-6
FRS-R-7
FRS-R-8
FRS-R-9
FRS-R-10
FRS-R-12
FRS-R-15
FRS-R-20
FRS-R-25
FRS-R-30
FRS-R-35
FRS-R-40
FRS-R-45
FRS-R-50
FRS-R-60
FRS-R-70
FRS-R-75
FRS-R-80
FRS-R-90
FRS-R-100
FRS-R-110
FRS-R-125
FRS-R-150
FRS-R-175
FRS-R-200
FRS-R-225
FRS-R-250
FRS-R-300
FRS-R-350
FRS-R-400
FRS-R-450
FRS-R-500
FRS-R-600
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
RK5
ITALWEBER
ul / csa
fusibili a standard ul-Csa - serie f rapidi e t ritardati a 600V, Con omologazioni
SeRieS F FaST-aCTing anD T TiMe-DeLay 600V FuSeS, aCCoRDing To uL/CSa STanDaRDS
app
appRoVeD
fusibili omologati per il nord-ameriCa
Classe “supplemental” a 250V e 600V
noRTH-aMeRiCa appRoVeD FuSeS
CLaSS “SuppLeMenTaL” aT 250V anD 600V
Norme - Standards UL 248-14, CSA C22.2
I fusibili di questa pagina appartengono alla classe UL/CSA denominata “supplemental”. Si tratta di fusibili di tipo rapido e di tipo ritardato che, rispetto ai fusibili delle
altre classi, hanno un potere di interruzione più basso, ma di contro hanno dimensioni
molto compatte e costo contenuto. In particolare i fusibili FNM e FNQ sono di tipo
ritardato e trovano applicazione per la protezione dal corto circuito di motori e di
apparecchiature che presentano correnti di spunto all’avvio. I fusibili BAF e KTK sono
invece di tipo rapido e trovano applicazione nella protezione, sia dal sovraccarico che
dal corto circuito, di cavi e circuiti senza componenti induttive.
The fuses presented on this page all belong to the uL/CSa fuses class called
“supplemental”. They are fuses with a quick-acting and time-delay characteristic
that, compared to the fuses of the other classes, have a lower breaking capacity,
but have a very compact size and low cost. in particular, the FnM and FnQ are
time-delay fuses and are used for short-circuit protection of motors and
equipments that have inrush current at startup. The BaF and KTK are quickacting fuses and they are used for protection, both from overloads and short
circuits, of cables and circuits without inductive components.
fusibili a standard ul-Csa - serie f rapidi e t ritardati a 250V - Con omologazioni
SeRieS F FaST-aCTing anD T TiMe-DeLay 250V FuSeS - aCCoRDing To uL/CSa STanDaRDS
app
appRoVeD
tipo
type
Fusibile BAF-1
BaF-1 fuse
UL-10
10,3x38
serie F rapidi
F series fast-acting fuses
codice IW
descrizione
IW code
description
serie T ritardati
T series time-delay fuses
codice IW
descrizione
IW code
description
1800000 (1)
1800001 (1)
1800002 (1)
1800003
1800004
1800005
1800006
1800007
1800008
1800009
1800010
1800012
1800015
1800020 (1)
1800025 (1)
1800030 (1)
–
1800101
1800102
1800103
1800104
1800105
1800106
1800107
1800108
1800109
1800110
1800112
1800115
1800120
1800125
1800130
BAF-1/2
BAF-1
BAF-2
BAF-3
BAF-4
BAF-5
BAF-6
BAF-7
BAF-8
BAF-9
BAF-10
BAF-12
BAF-15
BAF-20
BAF-25
BAF-30
(1) Tipi non omologati / 125V
–
FNM-1
FNM-2
FNM-3
FNM-4
FNM-5
FNM-6
FNM-7
FNM-8
FNM-9
FNM-10
FNM-12
FNM-15
FNM-20
FNM-25
FNM-30
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
0,5A
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
15A
20A
25A
30A
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
(1) Types without any approval / 125V
fusibili a standard ul-Csa - serie f rapidi e t ritardati a 600V - Con omologazioni
SeRieS F FaST-aCTing anD T TiMe-DeLay 600V FuSeS - aCCoRDing To uL/CSa STanDaRDS
app
appRoVeD
tipo
type
Fusibile FNQ-4
FnQ-4 fuse
UL-10
10,3x38
serie F rapidi
F series fast-acting fuses
codice IW
descrizione
IW code
description
serie T ritardati
T series time-delay fuses
codice IW
dwescrizione
IW code
description
1810625
1800201
1800202
1800203
1800204
1800205
1800206
1800207
1800208
1800209
1800210
1800212
1800215
1800220
1800225
1800230
1800300 (1)
1800301 (1)
1800302 (1)
1800303 (1)
1800304 (1)
1800305 (1)
1800306 (1)
1800307 (1)
1800308 (1)
1800309 (1)
1800310 (1)
1800312 (1)
1800315 (1)
1800320 (1)
1800325 (1)
1800330 (1)
(1) 500V
176
Dimensioni: pagina 190 - Caratteristiche tecniche: pagina 190
Dimensions: page 190 - Technical specifications: page 190
KTK-1/2
KTK-1
KTK-2
KTK-3
KTK-4
KTK-5
KTK-6
KTK-7
KTK-8
KTK-9
KTK-10
KTK-12
KTK-15
KTK-20
KTK-25
KTK-30
FNQ-1/2
FNQ-1
FNQ-2
FNQ-3
FNQ-4
FNQ-5
FNQ-6
FNQ-7
FNQ-8
FNQ-9
FNQ-10
FNQ-12
FNQ-15
FNQ-20
FNQ-25
FNQ-30
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
0,5A
1A
2A
3A
4A
5A
6A
7A
8A
9A
10A
12A
15A
20A
25A
30A
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
(1) 500V
ITALWEBER
fusibili omologati per il nord-ameriCa
Classe “CC” a 600V
noRTH-aMeRiCa appRoVeD FuSeS
CLaSS “CC” aT 600V
Norme - Standards UL 248-4, CSA C22.2
I fusibili di questa pagina appartengono alla classe di fusibili UL/CSA denominata CC
(sigla che non ha nulla a che fare con la corrente continua). Si tratta di fusibili rapidi e
ritardati utilizzabili nei cosiddetti “branch circuits”. Il loro potere di interruzione è di
200kA. Sono di tipo “rejection type”, cioè hanno una polarizzazione e vanno utilizzati in combinazione con gli appositi portafusibili della serie BCC (vedi pag. 185). I fusibili KTK-R sono di tipo rapido, mentre i fusibili FNQ-R sono di tipo ritardato. I fusibili
LP-CC presentano una curva di intervento che, per basse sovracorrenti può essere
considerata di tipo ritardato, mentre per correnti di corto circuito diventa di tipo rapido.
The fuses featured on this page belong to the uL/CSa fuses class called CC (an
acronym that has nothing to do with direct current). They are quick-acting and
time-delay fuses used in so-called “branch circuits”. Their breaking capacity is
200ka. They are fuses of “rejection type” and should be used only in combination
with the fuseholders of the BCC series (see page 185). Fuses KTK-R are of quickacting type, while FnQ-R fuses are of time-delay type. The Lp-CC fuses present a
time-current characteristic that, for low overcurrents, can be considered of timedelay type, while for short circuit currents becomes of quick-acting type.
fusibili rapidi a standard ul-Csa - Classe CC a 600V - Con omologazioni
CLaSS CC 600V FaST-aCTing FuSeS - aCCoRDing To uL-CSa STanDaRDS appRoVeD
UL-10F CC
uL-10F CC fuse
UL-10F CC
10,3x38
codice IW
IW code
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
1808000
1808001
1808031
1808002
1808032
1808003
1808033
1808004
1808005
1808006
1808007
1808008
1808009
1808010
1808012
1808015
1808020
1808025
1808030
KTK-R-1/2
KTK-R-1
KTK-R-1-1/2
KTK-R-2
KTK-R-2-1/2
KTK-R-3
KTK-R-3-1/2
KTK-R-4
KTK-R-5
KTK-R-6
KTK-R-7
KTK-R-8
KTK-R-9
KTK-R-10
KTK-R-12
KTK-R-15
KTK-R-20
KTK-R-25
KTK-R-30
0,5A
1A
1,5A
2A
2,5A
3A
3,5A
4A
5A
6A
7A
8A
9A
10A
12A
15A
20A
25A
30A
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
ul / csa
tipo
type
fusibili ritardati a standard ul-Csa - Classe CC a 600V - Con omologazioni
CLaSS CC 600V TiMe-DeLay FuSeS - aCCoRDing To uL-CSa STanDaRDS appRoVeD
tipo
type
UL-10T CC
uL-10T CC fuse
UL-10T CC
10,3x38
177
Caratteristiche tecniche: pagina 191
Technical specifications: page 191
codice IW
IW code
descrizione
description
codice IW
IW code
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
1809000
1809001
1809033
1809002
1809034
1809003
1809035
1809004
1809005
1809006
1809007
1809008
1809009
1809010
1809012
1809015
1809020
1809025
1809030
FNQ-R-1/2
FNQ-R-1
FNQ-R-1-1/2
FNQ-R-2
FNQ-R-2-1/2
FNQ-R-3
FNQ-R-3-1/2
FNQ-R-4
FNQ-R-5
FNQ-R-6
FNQ-R-7
FNQ-R-8
FNQ-R-9
FNQ-R-10
FNQ-R-12
FNQ-R-15
FNQ-R-20
FNQ-R-25
FNQ-R-30
1808050
1808051
1808084
1808052
1808082
1808053
1808083
1808054
1808055
1808056
1808057
1808058
1808059
1808060
1808062
1808065
1808070
1808075
1808080
LP-CC-1/2
LP-CC-1
LP-CC-1-1/2
LP-CC-2
LP-CC-2-1/2
LP-CC-3
LP-CC-3-/12
LP-CC-4
LP-CC-5
LP-CC-6
LP-CC-7
LP-CC-8
LP-CC-9
LP-CC-10
LP-CC-12
LP-CC-15
LP-CC-20
LP-CC-25
LP-CC-30
0,5A
1A
1,5A
2A
2,5A
3A
3,5A
4A
5A
6A
7A
8A
9A
10A
12A
15A
20A
25A
30A
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
ITALWEBER
fusibili omologati per il nord-ameriCa
Classe “J” a 600V
noRTH-aMeRiCa appRoVeD FuSeS
CLaSS “J” aT 600V
Norme - Standards UL 248-8, UL 248-12, CSA C22.2
I fusibili appartenenti alla classe di fusibili a standard UL/CSA denominata J sono del
tipo a limitazione di corrente, e possono essere utilizzati per la protezione di qualunque tipo di circuito (main, feeder and branch). In particolare i fusibili della serie
LPJ-SP sono di tipo ritardato, hanno potere di interruzione di 300kA, e trovano
applicazione per la protezione dal corto circuito di motori e di apparecchiature che
presentano correnti di spunto all’avvio. I fusibili della serie JKS sono di tipo rapido,
hanno potere di interruzione di 200kA e trovano applicazione nella protezione, sia
dal sovraccarico che dal corto circuito, di cavi e circuiti senza componenti induttive.
The fuses belonging to the to the uL/CSa fuses class called J are current limiting
fuses, and they can be used to protect any type of circuit (main, feeder and
branch). in particular, the fuses series LpJ-Sp have a time-current characteristic of
time-delay type, they have breaking capacity of 300ka, and they are used for
short-circuit protection of motors and equipments that have inrush current at
startup. The fuses series JKS have a quick-acting time-current characteristic, they
have a breaking capacity of 200ka and they are used for protection, both from
overloads and short circuits, of cables and circuits without inductive components.
fusibili a standard ul-Csa - Classe J a 600V - Con omologazioni
CLaSS J FuSeS 600V - aCCoRDing To uL-CSa STanDaRDS appRoVeD
app
tipo
type
Fusibile LPJ-40SP
LpJ-40Sp fuse
WPJ-21
21x57
Fusibile LPJ-175SP
LpJ-175Sp fuse
WPJ-27
27x60
WPJ-29
29x117
WPJ-41
41x146
WPJ-54
54x181
WPJ-64
64x203
178
tipo LPJ ritardati
type LPJ time-delay fuses
codice IW
descrizione
IW code
description
tipo JKS rapidi
type JKS fast-acting fuses
codice IW
descrizione
IW code
description
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
1807001
1807002
1807003
1807004
1807005
1807006
1807007
1807008
1807010
1807012
1807015
1807017
1807020
1807025
1807030
1807035
1807040
1807045
1807050
1807060
1807070
1807080
1807090
1807100
1807110
1807125
1807150
1807175
1807200
1807225
1807250
1807300
1807350
1807400
1807450
1807500
1807600
1806001
1806002
1806003
1806004
1806005
1806006
–
1806008
1806010
1806012
1806015
–
1806020
1806025
1806030
1806035
1806040
1806045
1806050
1806060
1806070
1806080
1806090
1806100
1806110
1806125
1806150
1806175
1806200
1806225
1806250
1806300
1806350
1806400
1806450
1806500
1806600
1A
2A
3A
4A
5A
6A
7A
8A
10A
12A
15A
17,5A
20A
25A
30A
35A
40A
45A
50A
60A
70A
80A
90A
100A
110A
125A
150A
175A
200A
225A
250A
300A
350A
400A
450A
500A
600A
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Dimensioni: pagina 192 - Caratteristiche tecniche: pagine 192-193
Dimensions: page 192 - Technical specifications: pages 192-193
LPJ-1SP
LPJ-2SP
LPJ-3SP
LPJ-4SP
LPJ-5SP
LPJ-6SP
LPJ-7SP
LPJ-8SP
LPJ-10SP
LPJ-12SP
LPJ-15SP
LPJ-17,5SP
LPJ-20SP
LPJ-25SP
LPJ-30SP
LPJ-35SP
LPJ-40SP
LPJ-45SP
LPJ-50SP
LPJ-60SP
LPJ-70SP
LPJ-80SP
LPJ-90SP
LPJ-100SP
LPJ-110SP
LPJ-125SP
LPJ-150SP
LPJ-175SP
LPJ-200SP
LPJ-225SP
LPJ-250SP
LPJ-300SP
LPJ-350SP
LPJ-400SP
LPJ-450SP
LPJ-500SP
LPJ-600SP
JKS-1
JKS-2
JKS-3
JKS-4
JKS-5
JKS-6
–
JKS-8
JKS-10
JKS-12
JKS-15
–
JKS-20
JKS-25
JKS-30
JKS-35
JKS-40
JKS-45
JKS-50
JKS-60
JKS-70
JKS-80
JKS-90
JKS-100
JKS-110
JKS-125
JKS-150
JKS-175
JKS-200
JKS-225
JKS-250
JKS-300
JKS-350
JKS-400
JKS-450
JKS-500
JKS-600
ITALWEBER
fusibili omologati per il nord-ameriCa
Classe “J” a 600V
noRTH-aMeRiCa appRoVeD FuSeS
CLaSS “J” aT 600V
Norme - Standards UL 248-8, CSA C22.2
I fusibili presentati in questa pagina appartengono alla classe di fusibili UL/CSA denominata J. Essi sono fusibili con caratteristica di intervento di tipo extrarapido e sono
fusibili del tipo a limitazione di corrente. Il corpo di questi fusibili è realizzato in melamina e l’elemento fusibile interno è in argento puro. Questi fusibili possono anche
essere utilizzati in corrente continua fino ad un massimo di 450V DC (in questo caso
l’omologazione UL è valida solo per fusibili da 30A a 600A). Questi fusibili sono tipicamente utilizzati per la protezione di AC e DC drives e di apparecchiature che contengono semiconduttori.
The fuses featured on this page belong to the uL/CSa fuses class called J. They
are fuses with a time-current characteristic of high speed type and they are
current-limiting fuses. The body of these fuses is made of melamine and the
internal fuse element is made of pure silver. These fuses may also be used in
direct current applications up to a maximum of 450V DC (in this case the uL
approval is valid only for fuses from 30a to 600a). These fuses are typically used
for the protection of aC and DC drives and equipments that contain
semiconductors.
tipo
type
DFJ-21
21x57
Fusibile DFJ-100
DFJ-100 fuse
DFJ-27
27x60
DFJ-29
29x117
DFJ-41
41x146
DFJ-54
54x181
DFJ-64
64x203
179
codice IW
IW code
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
1809050
1809051
1809052
1809053
1809054
1809055
1809056
1809057
1809058
1809059
1809060
1809061
1809062
1809063
1809064
1809065
1809066
1809067
1809068
1809069
1809070
1809071
1809072
1809073
1809074
1809075
1809076
1809077
1809078
1809079
1809080
1809081
1809082
1809083
1809084
DFJ-1
DFJ-2
DFJ-3
DFJ-4
DFJ-5
DFJ-6
DFJ-8
DFJ-10
DFJ-12
DFJ-15
DFJ-20
DFJ-25
DFJ-30
DFJ-35
DFJ-40
DFJ-45
DFJ-50
DFJ-60
DFJ-70
DFJ-80
DFJ-90
DFJ-100
DFJ-110
DFJ-125
DFJ-150
DFJ-175
DFJ-200
DFJ-225
DFJ-250
DFJ-300
DFJ-350
DFJ-400
DFJ-450
DFJ-500
DFJ-600
1A
2A
3A
4A
5A
6A
8A
10A
12A
15A
20A
25A
30A
35A
40A
45A
50A
60A
70A
80A
90A
100A
110A
125A
150A
175A
200A
225A
250A
300A
350A
400A
450A
500A
600A
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
Dimensioni: pagina 192 - Caratteristiche tecniche: pagina 193
Dimensions: page 192 - Technical specifications: page 193
ITALWEBER
ul / csa
fusibili eXtrarapidi a standard ul-Csa - Classe J a 600V - Con omologazioni
CLaSS J 600V HigH SpeeD FuSeS - aCCoRDing To uL-CSa STanDaRDS appRoVeD
fusibili omologati per il nord-ameriCa
Classe “rk1” e Classe “t”
noRTH-aMeRiCa appRoVeD FuSeS
CLaSS “RK1” anD CLaSS “T”
Norme - Standards UL 248-12, UL 248-15, CSA C22.2
I fusibili presentati in questa pagina appartengono alle classi di fusibili UL/CSA denominate RK1 e T. In particolare i fusibili KTN-R e KTS-R appartengono entrambi alla
classe RK1 e sono di tipo rapido. Il loro potere di interruzione è di 200kA e sono del
tipo a limitazione di corrente. Sono utilizzati per proteggere, sia dal sovraccarico che
dal corto circuito, cavi e circuiti senza componenti induttive. I fusibili JJN e JJS appartengono alla classe T, sono di tipo rapido a limitazione di corrente, e con potere di
interruzione di 200kA. Le applicazioni sono le stesse dei fusibili della classe RK1, ma
rispetto ad essi presentano delle dimensioni ridotte.
The fuses featured on this page belong to the uL/CSa fuses classes called RK1
and T. in particular, the fuses KTn-R and KTS-R belong to the class RK1 and are
quick-acting fuses. Their breaking capacity is 200ka and they are current limiting
fuses. They are used to protect, from overloads and short circuits, cables and
circuits without inductive components. The fuses JJn and JJS belong to the
uL/CSa class T, they have a quick-acting characteristic, they are current limiting
fuses and have a breaking capacity of 200ka. The applications are the same as
the class RK1 fuses, but compared to them, they have much more compact size.
fusibili rapidi a standard ul-Csa - Classe rk1 - Con omologazioni
CLaSS RK1 FaST-aCTing FuSeS - aCCoRDing To uL-CSa STanDaRDS appRoVeD
tipo
type
14x51 (250V)
21x127 (600V)
Fusibile KTN-R-30
KTn-R-30 fuse
21x76 (250V)
27x139 (600V)
27x149 (250V)
34x200 (600V)
40x181 (250V)
46x244 (600V)
53x219 (250V)
66x295 (600V)
Fusibile KTN-R-200
KTn-R-200 fuse
66x264 (250V)
80x340 (600V)
codice IW
IW code
250V
1809100
1809101
1809105
1809106
1809107
1809108
1809109
1809110
1809111
1809112
1809113
1809114
1809116
1809117
1809120
1809121
1809122
1809124
1809125
1809127
1809129
1809130
1809132
1809133
1809134
1809135
descrizione
description
codice IW
IW code
KTN-R-1
KTN-R-2
KTN-R-6
KTN-R-8
KTN-R-10
KTN-R-12
KTN-R-15
KTN-R-20
KTN-R-25
KTN-R-30
KTN-R-35
KTN-R-40
KTN-R-50
KTN-R-60
KTN-R-80
KTN-R-90
KTN-R-100
KTN-R-125
KTN-R-150
KTN-R-200
KTN-R-250
KTN-R-300
KTN-R-400
KTN-R-450
KTN-R-500
KTN-R-600
1809150
1809151
1809155
1809156
1809157
1809158
1809159
1809160
1809161
1809162
1809163
1809164
1809166
1809167
1809170
1809171
1809172
1809174
1809175
1809177
1809179
1809180
1809182
1809183
1809184
1809185
600V
descrizione
description
In (A)
In (A)
conf.
pack.
KTS-R-1
KTS-R-2
KTS-R-6
KTS-R-8
KTS-R-10
KTS-R-12
KTS-R-15
KTS-R-20
KTS-R-25
KTS-R-30
KTS-R-35
KTS-R-40
KTS-R-50
KTS-R-60
KTS-R-80
KTS-R-90
KTS-R-100
KTS-R-125
KTS-R-150
KTS-R-200
KTS-R-250
KTS-R-300
KTS-R-400
KTS-R-450
KTS-R-500
KTS-R-600
1A
2A
6A
8A
10A
12A
15A
20A
25A
30A
35A
40A
50A
60A
80A
90A
100A
125A
150A
200A
250A
300A
400A
450A
500A
600A
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-5
1-5
1-5
1
1
1
1
1
1
1
1
1
descrizione
description
In (A)
In (A)
conf.
pack.
JJS-1
JJS-2
JJS-6
JJS-10
JJS-15
JJS-20
JJS-30
JJS-35
JJS-40
JJS-50
JJS-60
JJS-80
JJS-90
JJS-100
JJS-125
JJS-150
JJS-200
JJS-250
JJS-300
JJS-400
JJS-450
JJS-500
JJS-600
1A
2A
6A
10A
15A
20A
30A
35A
40A
50A
60A
80A
90A
100A
125A
150A
200A
250A
300A
400A
450A
500A
600A
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-5
1-5
1-5
1
1
1
1
1
1
1
1
1
fusibili rapidi a standard ul-Csa - Classe t - Con omologazioni
CLaSS T FaST-aCTing FuSeS - aCCoRDing To uL-CSa STanDaRDS appRoVeD
tipo
type
Fusibile JJN-30
JJn-30 fuse
10x22 (300V)
10x38 (600V)
14x22 (300V)
21x39 (600V)
19x55 (300V)
19x75 (600V)
22x62 (300V)
22x83 (600V)
Fusibile JJS-30
JJS-30 fuse
25x70 (300V)
25x92 (600V)
32x78 (300V)
32x102 (600V)
180
codice IW
IW code
–
1809201
1809203
1809204
1809205
1809206
1809208
–
1809210
1809212
1809213
1809215
1809216
1809217
1809219
1809220
1809222
1809224
1809225
1809227
1809228
1809229
1809230
300V
descrizione
description
codice IW
IW code
–
JJN-2
JJN-6
JJN-10
JJN-15
JJN-20
JJN-30
–
JJN-40
JJN-50
JJN-60
JJN-80
JJN-90
JJN-100
JJN-125
JJN-150
JJN-200
JJN-250
JJN-300
JJN-400
JJN-450
JJN-500
JJN-600
1809250
1809251
1809253
1809254
1809255
1809256
1809258
1809259
1809260
1809262
1809263
1809265
1809266
1809267
1809269
1809270
1809272
1809274
1809275
1809277
1809278
1809279
1809280
Dimensioni: pagine 194-195 - Caratteristiche tecniche: pagine 194-195
Dimensions: pages 194-195 - Technical specifications: pages 194-195
600V
ITALWEBER
fusibili omologati per il nord-ameriCa
tipo “klm” e tipo “dmm-b”
noRTH-aMeRiCa appRoVeD FuSeS
Type “KLM” anD Type “DMM-B”
Norme - Standards UL 248-14, CSA C22.2
I fusibili KLM appartengono alla classe di fusibili UL/CSA denominata “supplemental”. Essi sono del tipo rapido, e possono essere utilizzati anche in circuiti operanti
in corrente continua fino a 600V DC (in questo caso l’omologazione UL è valida da
500mA a 30A). Il loro potere di interruzione è di 100kA se utilizzati in corrente
alternata (AC), o di 50kA se utilizzati in corrente continua (DC). I fusibili tipo DMM-B
sono utilizzabili fino a 1000V AC e DC, ma il loro utilizzo è limitato alla sola protezione dei multimetri. Il corpo di questi fusibili è realizzato in melamina ed i contatti
sono in ottone nichelato.
The fuses of the KLM series belong to the uL/CSa fuses class called
"supplemental". They have a quick-acting characteristic, and they can also be
used in circuits operating in direct current up to 600V DC (in this case the uL
approval is valid from 500ma to 30a). Their breaking capacity is 100ka when
used in alternating current (aC), or 50 ka when used in direct current (DC). The
fuses type DMM-B can be used up to 1000V aC and DC, but their use is
exclusively limited to the protection of multimeters. The body of these fuses is
made of melamine and the contacts are made by nickel plated brass.
tipo
type
Fusibile KLM-1
KLM-1 fuse
UL-10F
10,3x38
codice IW
IW code
descrizione
description
1809300
1809301
1809302
1809303
1809304
1809305
1809306
1809307
1809308
1809309
1809310
1809311
1809312
1809313
1809314
1809315
1809316
1809317
1809318
1809319
1809320
KLM-1/10
KLM-1/8
KLM-2/10
KLM-1/4
KLM-3/10
KLM-1/2
KLM-3/4
KLM-1
KLM-1-1/2
KLM-2
KLM-3
KLM-4
KLM-5
KLM-6
KLM-8
KLM-10
KLM-12
KLM-15
KLM-20
KLM-25
KLM-30
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
100mA
125mA
200mA
250mA
300mA
500mA
750mA
1A
1,5A
2A
3A
4A
5A
6A
8A
10A
12A
15A
20A
25A
30A
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
600V AC/DC
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
1-10
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
440mA
11A
1000V AC/DC
1000V AC/DC
1-10
1-10
fusibili rapidi a standard ul-Csa - tensione 1000V - Con omologazione
FaST-aCTing FuSeS - VoLTage 1000V - aCCoRDing To uL-CSa STanDaRD appRoVeD
tipo
type
codice IW
IW code
descrizione
description
UL-10F
10,3x35
1810223
1810622
DMM-B-44/100
DMM-B-11
Fusibile DMM-B-44/100
DMM-B-44/100 fuse
181
Dimensioni: pagina 196 - Caratteristiche tecniche: pagina 196
Dimensions: page 196 - Technical specifications: page 196
ITALWEBER
ul / csa
fusibili rapidi a standard ul-Csa - tensione 600V - Con omologazioni
FaST-aCTing FuSeS - VoLTage 600V - aCCoRDing To uL-CSa STanDaRDS appRoVeD
fusibili omologati per il nord-ameriCa
eXtrarapidi fissaggio a bullone - serie “fWX” e “fWh”
noRTH-aMeRiCa appRoVeD FuSeS
HigH SpeeD SCRew Fixing - SeRieS “Fwx” anD “FwH”
Norme - Standards UL 248-13
I fusibili della serie FWX sono di tipo extrarapido, con potere di interruzione di
200kA, e possono essere utilizzati anche in corrente continua fino ad un massimo
di 250V DC. Anche i fusibili della serie FWH sono di tipo extrarapido, con potere di
interruzione di 200kA, e possono essere utilizzati anche in corrente continua fino ad
un massimo di 500V DC. Grazie alla loro caratteristica di intervento di tipo extrarapido ed al loro basso valore di energia specifica passante (I2t), questi fusibili sono
ideali per la protezione di tutte quelle apparecchiature che contengono semiconduttori: inverter, AC e DC drives, soft-starters, ecc.
The fuses of the Fwx series are high speed fuses, with a breaking capacity of
200ka, and they can also be used in direct current applications up to a
maximum of 250V DC. even the FwH fuses are high speed fuses, with a
breaking capacity of 200ka, and they can also be used in direct current
applications up to a maximum of 500V DC. Due to their high speed timecurrent characteristic and to their low value of specific let-through energy (i2t),
these fuses are ideal for the protection of equipments that contain
semiconductors: inverter, aC and DC drives, soft-starters, etc.
fusibili eXtrarapidi - serie fWX 250V - Con omologazione
HigH SpeeD FuSeS SeRieS Fwx 250V appRoVeD
Fusibile FWX-700A
Fwx-700a fuse
codice IW
IW code
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
I2t totale (A2s)
total I2t (A2s)
Pw (W)
Pw (W)
1771035
1771040
1771050
1771063
1771080
1771100
1771125
1771150
1771175
1771200
1771225
1771250
1771300
1771350
1771400
1771500
1771600
1771700
1771800
1771900 (1)
1771920 (1)
1771950 (1)
1771980 (1)
1771990 (1)
FWX-35A
FWX-40A
FWX-50A
FWX-60A
FWX-80A
FWX-100A
FWX-125A
FWX-150A
FWX-175A
FWX-200A
FWX-225A
FWX-250A
FWX-300A
FWX-350A
FWX-400A
FWX-500A
FWX-600A
FWX-700A
FWX-800A
FWX-1000AH
FWX-1200AH
FWX-1500AH
FWX-2000AH
FWX-2500AH
35A
40A
50A
60A
80A
100A
125A
150A
175A
200A
225A
250A
300A
350A
400A
500A
600A
700A
800A
1000A
1200A
1500A
2000A
2500A
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
230
310
520
740
1.850
3.150
4.850
6.950
9.300
12.000
14.700
18.100
27.300
48.600
66.100
128.000
188.000
190.000
230.000
360.000
750.000
880.000
2.300.000
4.700.000
4,2
5,2
6,0
8,1
8,1
10,0
12,5
15,7
18,5
22,0
24,0
27,0
32,0
39,0
44,0
54,0
62,0
72,0
84,0
100,0
103,0
140,0
151,0
163,0
N.B. Montaggio su basi a blocchi vedi pagina 186
(1) Modelli senza omologazione
conf.
pack.
5
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N.B. Fixing on modular fuse blocks see page 186
(1) Version without
approval
fusibili eXtrarapidi - serie fWh 500V - Con omologazione
H 500V HigH SpeeD FuSeS SeRieS FwH
appRoVeD
Fusibile FWH-200B
FwH-200B fuse
codice IW
IW code
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
I2t totale (A2s)
total I2t (A2s)
Pw (W)
Pw (W)
1772035
1772040
1772050
1772060
1772080
1772100
1772125
1772150
1772175
1772200
1772225
1772250
1772300
1772325
1772350
1772400
1772500
1772600
1772700
1772800
1772900
1772920 (1)
1772940 (1)
1772960 (1)
FWH-35B
FWH-40B
FWH-50B
FWH-60B
FWH-80B
FWH-100B
FWH-125B
FWH-150B
FWH-175B
FWH-200B
FWH-225A
FWH-250A
FWH-300A
FWH-325A
FWH-350A
FWH-400A
FWH-500A
FWH-600A
FWH-700A
FWH-800A
FWH-1000A
FWH-1200A
FWH-1400A
FWH-1600A
35A
40A
50A
60A
80A
100A
125A
150A
175A
200A
225A
250A
300A
325A
350A
400A
500A
600A
700A
800A
1000A
1200A
1400A
1600A
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
500V
150
320
670
900
1.400
2.000
2.500
4.600
6.200
8.500
23.300
32.200
49.800
63.800
72.900
96.700
149.000
206.000
298.000
409.000
450.000
600.000
1.000.000
1.400.000
8,0
7,5
7,5
9,9
12,7
17,0
25,0
30,0
35,0
40,0
39,0
41,0
51,0
53,0
58,0
65,0
84,0
108,0
120,0
129,0
145,0
180,0
210,0
230,0
N.B. Montaggio su basi a blocchi vedi pagina 186
(1) Modelli senza omologazione
182
Dimensioni: pagine 197-198 - Caratteristiche tecniche: pagine 197-198
Dimensions: pages 197-198 - Technical specifications: pages 197-198
conf.
pack.
5
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N.B. Fixing on modular fuse blocks see page 186
(1) Version without
approval
ITALWEBER
fusibili omologati per il nord-ameriCa
eXtrarapidi fissaggio a bullone - serie “fWp” e “fWJ”
noRTH-aMeRiCa appRoVeD FuSeS
HigH SpeeD SCRew Fixing - SeRieS “Fwp” anD “FwJ”
Norme - Standards UL 248-13
I fusibili della serie FWP sono di tipo extrarapido, con potere di interruzione di
200kA, e possono essere utilizzati anche in corrente continua fino ad un massimo
di 700V DC (50kA). Anche i fusibili della serie FWJ sono di tipo extrarapido, con
potere di interruzione di 200kA, e possono essere utilizzati anche in corrente continua fino ad un massimo di 800V DC (solo correnti nominali da 30A a 200A e da
450A a 600A). Grazie alla loro caratteristica extrarapida ed al loro basso valore di
energia specifica passante (I2t), questi fusibili sono ideali per la protezione di apparecchiature contenenti semiconduttori: inverter, AC e DC drives, soft-starters, ecc.
The fuses of the Fwp series are high speed fuses, with breaking capacity of
200ka, and they can also be used in direct current up to a maximum of 700V
DC (50ka). even the FwJ series fuses are high speed fuses, with breaking capacity of 200ka, and they can also be used in direct current up to a maximum of
800V DC (only nominal currents from 30a to 200a and from 450a to 600a).
Due to their high speed characteristic and to their low value of specific letthrough energy (i2t), these fuses are ideal for the protection of equipments
containing semiconductors: inverter, aC and DC drives, soft starters, etc.
fusibili eXtrarapidi - serie fWp 700V - Con omologazione
HigH SpeeD FuSeS SeRieS Fwp 700V appRoVeD
Fwp-200a fuse
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
I2t totale (A2s)
total I2t (A2s)
Pw (W)
Pw (W)
1776020 (1)
1776025 (1)
1776030 (1)
1776035
1776040
1776050
1776060
1776070
1776080
1776090
1776100
1776125
1776150
1776175
1776200
1776250
1776300
1776350
1776400
1776450
1776500
1776600
1776700
1776800
1776900 (1)
1776920 (1)
1776940 (1)
FWP-20B
FWP-25B
FWP-30B
FWP-35B
FWP-40B
FWP-50B
FWP-60B
FWP-70B
FWP-80B
FWP-90B
FWP-100B
FWP-125A
FWP-150A
FWP-175A
FWP-200A
FWP-250A
FWP-300A
FWP-350A
FWP-400A
FWP-450A
FWP-500A
FWP-600A
FWP-700A
FWP-800A
FWP-900A
FWP-1000A
FWP-1200A
20A
25A
30A
35A
40A
50A
60A
70A
80A
90A
100A
125A
150A
175A
200A
250A
300A
350A
400A
450A
500A
600A
700A
800A
900A
1000A
1200A
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
700V
180
340
450
160
320
600
950
2.000
2.400
2.700
3.500
7.300
11.700
16.700
22.000
42.500
71.200
95.600
125.000
137.000
170.000
250.000
300.000
450.000
530.000
600.000
1.100.000
6,0
7,0
9,0
12,0
12,0
12,0
15,5
18,0
21,0
25,0
27,0
28,0
32,0
35,0
43,0
48,0
58,0
65,0
78,0
94,0
107,0
122,0
125,0
140,0
150,0
170,0
190,0
N.B. Montaggio su basi a blocchi vedi pagina 186
(1) Modelli senza omologazione
conf.
pack.
10
10
10
5
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N.B. Fixing on modular fuse blocks see page 186
(1) Version without
approval
fusibili eXtrarapidi - serie fWJ 1000V - Con omologazione
HigH SpeeD FuSeS SeRieS FwJJ 1000V appRoVeD
Fusibile FWJ-300A
FwJ-300a fuse
codice IW
IW code
descrizione
description
In (A)
In (A)
Vn (V)
Vn (V)
I2t totale (A2s)
total I2t (A2s)
Pw (W)
Pw (W)
1779035
1779040
1779050
1779060
1779070
1779080
1779090
1779100
1779125
1779150
1779175
1779200
1779250
1779300
1779350
1779400
1779500
1779600
1779800 (1)
1779900 (1)
1779910 (1)
1779930 (1)
1779950 (1)
FWJ-35A
FWJ-40A
FWJ-50A
FWJ-60A
FWJ-70A
FWJ-80A
FWJ-90A
FWJ-100A
FWJ-125A
FWJ-150A
FWJ-175A
FWJ-200A
FWJ-250A
FWJ-300A
FWJ-350A
FWJ-400A
FWJ-500A
FWJ-600A
FWJ-800A
FWJ-1000A
FWJ-1200A
FWJ-1600A
FWJ-2000A
35A
40A
50A
60A
70A
80A
90A
100A
125A
150A
175A
200A
250A
300A
350A
400A
500A
600A
800A
1000A
1200A
1600A
2000A
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
1000V
2.000
2.500
3.500
5.000
6.900
9.700
12.000
17.500
35.000
45.000
65.000
80.000
112.000
164.000
231.000
330.000
329.000
520.000
500.000
1.100.000
2.100.000
4.000.000
7.600.000
7
8
10
11
12
13
14
15
16
25
30
32
50
56
62
67
95
105
182
206
240
267
244
N.B. Montaggio su basi a blocchi vedi pagina 186
(1) Modelli senza omologazione
183
Dimensioni: pagine 199-200 - Caratteristiche tecniche: pagine 199-200
Dimensions: pages 199-200 - Technical specifications: pages 199-200
conf.
pack.
10
10
10
10
10
10
10
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N.B. Fixing on modular fuse blocks see page 186
(1) Version without
approval
ITALWEBER
ul / csa
Fusibile FWP-200A
codice IW
IW code
fusibili omologati per il nord-ameriCa
portafusibili per fusibili Classi “k5”-“h”-“rk5”-“rk1”
noRTH-aMeRiCa appRoVeD FuSeS
FuSe BaSeS FoR CLaSSeS “K5”-“H”-“RK5”-“RK1”
Norme - Standards UL 248-14, UL 248-12, UL 248-9, UL 248-6, CSA C22.2
Le basi portafusibili per i fusibili di classe K5, H, RK5 e RK1, nelle versioni a 250V
ed a 600V, sono realizzate con materiali termoplastici autoestinguenti UL-94 V0, e
resistenti alle elevate temperature. Esse sono disponibili nelle versioni unipolare,
bipolare (solo per basse correnti) e tripolare. Le basi indicate con le lettere iniziali
HM e RM presentano un design completamente rinnovato rispetto ai modelli standard. Tutte le basi possono essere abbinate ad apposite calotte di protezione contro
i contatti accidentali (vedi pag. 187). Le basi H250 e H600 hanno valore SCCR di
10kA, le basi R250 e R600 hanno valore SCCR di 200kA.
The fuse bases for uL/CSa fuses of the classes K5, H, RK5 and RK1, with rated
voltage of 250V and 600V, are made of self-extinguishing thermoplastic uL
94-V0 material. They are available in single pole, double pole (only for low
currents) and three poles versions. The fuse bases indicated with the initial
letters HM and RM have a completely new design compared to the standard
models. all fuse bases can be associated with special covers to protect against
accidental contact (see page 187). The bases H250 and H600 have SCCR value
of 10ka, the bases R250 and R600 have SCCR value of 200ka.
portafusibili per fusibili Classi k5-h-rk5-rk1 a 250V - Con omologazioni
FuSe BaSeS FoR 250V CLaSSeS K5-H-RK5-RK1 FuSeS appRoVeD
app
Base tripolare
tipo H25030-3S
Three-poles base
type H25030-3S
per fusibili NON
for NON fuses
codice IW
tipo
IW code
type
per fusibili FRN-R / KTN-R
for FRN-R / KTN-R fuses
codice IW
tipo
IW code
type
2645031
2645032
2645033
2645061
2645062
2645063
2645100
2645103
2645105
2645108
2645200
2645203
2645400
2645403
2645600
2645603
2645031R
2645032R
2645033R
2645061R
2645062R
2645063R
2645100R
2645103R
2645105R
2645108R
2645200R
2645203R
2645400R
2645403R
2645600R
2645603R
H25030-1S
H25030-2S
H25030-3S
H25060-1C
H25060-2C
H25060-3C
H25100-1CR
H25100-3CR
HM25100-1CR
HM25100-3CR
HM25200-1CR
HM25200-3CR
HM25400-1CR
HM25400-3CR
HM25600-1CR
HM25600-3CR
R25030-1SR
R25030-2SR
R25030-3SR
R25060-1CR
R25060-2CR
R25060-3CR
R25100-1CR
R25100-3CR
RM25100-1CR
RM25100-3CR
RM25200-1CR
RM25200-3CR
RM25400-1CR
RM25400-3CR
RM25600-1CR
RM25600-3CR
n. poli
n. poles
tipo fusibile
fuse range
In (A)
In (A)
conf.
pack.
1
2
3
1
2
3
1
3
1
3
1
3
1
3
1
3
0,5A p 30A
0,5A p 30A
0,5A p 30A
35A p 60A
35A p 60A
35A p 60A
70A p 100A
70A p 100A
70A p 100A
70A p 100A
110A p 200A
110A p 200A
225A p 400A
225A p 400A
450A p 600A
450A p 600A
30A
30A
30A
60A
60A
60A
100A
100A
100A
100A
200A
200A
400A
400A
600A
600A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
portafusibili per fusibili Classi k5-h-rk5-rk1 a 600V - Con omologazioni
FuSe BaSeS FoR 600V CLaSSeS K5-H-RK5-RK1 FuSeS appRoVeD
app
Base unipolare
tipo H60030-1S
Single pole base
type H60030-1S
184
per fusibili NOS
for NOS fuses
codice IW
tipo
IW code
type
per fusibili FRS-R / KTS-R
for FRS-R / KTS-R fuses
codice IW
tipo
IW code
type
2646031
2646032
2646033
2646061
2646062
2646063
2646101
2646103
2646105
2646108
2646200
2646203
2646400
2646403
2646600
2646603
2646031R
2646032R
2646033R
2646061R
2646062R
2646063R
2646101R
2646103R
2646105R
2646108R
2646200R
2646203R
2646400R
2646403R
2646600R
2646603R
Dimensioni: pagine 201-202
Dimensions: pages 201-202
H60030-1S
H60030-2S
H60030-3S
H60060-1C
H60060-2C
H60060-3C
H60100-1CR
H60100-3CR
HM60100-1CR
HM60100-3CR
HM60200-1CR
HM60200-3CR
HM60400-1CR
HM60400-3CR
HM60600-1CR
HM60600-3CR
R60030-1SR
R60030-2SR
R60030-3SR
R60060-1CR
R60060-2CR
R60060-3CR
R60100-1CR
R60100-3CR
RM60100-1CR
RM60100-3CR
RM60200-1CR
RM60200-3CR
RM60400-1CR
RM60400-3CR
RM60600-1CR
RM60600-3CR
n. poli
n. poles
tipo fusibile
fuse range
In (A)
In (A)
conf.
pack.
1
2
3
1
2
3
1
3
1
3
1
3
1
3
1
3
0,5A p 30A
0,5A p 30A
0,5A p 30A
35A p 60A
35A p 60A
35A p 60A
70A p 100A
70A p 100A
70A p 100A
70A p 100A
110A p 200A
110A p 200A
225A p 400A
225A p 400A
450A p 600A
450A p 600A
30A
30A
30A
60A
60A
60A
100A
100A
100A
100A
200A
200A
400A
400A
600A
600A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
ITALWEBER
fusibili omologati per il nord-ameriCa
portafusibili per fusibili Classi “supplemental”-“CC”-“J”
noRTH-aMeRiCa appRoVeD FuSeS
FuSe BaSeS FoR CLaSSeS “SuppLeMenTaL”-“CC”-“J”
Norme - Standards UL 248-13
Sono qui presentate le basi portafusibili per fusibili classe CC, J e Supplemental. In
particolare le basi portafusibili per fusibili classe CC sono del tipo chiuso e sono anche
disponibili nella versione con LED di segnalazione dell’avvenuto intervento (SCCR =
200kA). Le basi portafusibili per fusibili classe J (SCCR = 200kA) sono disponibili
nella classica versione aperta (per tutte le correnti nominali) e nella versione chiusa
(solo per correnti fino a 60A). Le basi indicate con le lettere iniziali JM hanno un
design completamente rinnovato rispetto ai modelli standard. Le basi per i fusibili
classe Supplemental sono disponibili solo nella versione aperta (SCCR = 10kA).
on this page are presented uL/CSa fuse bases for class CC, J, and Supplemental
fuses. in particular, the fuse bases for class CC fuses are of closed type and are
also available with the LeD indication of the fuse operation (SCCR = 200ka).
The fuse bases for class J fuses (SCCR = 200ka) are available in the classic open
version (for all rated currents) and in the closed version (only for currents up to
60a). The bases marked with the initials letters JM have a completely new
design compared to the standard models. The fuse bases for fuses class
Supplemental are only available in the open type (SCCR = 10ka).
portafusibili per fusibili tipo baf / fnm / ktk / fnQ - Con omologazioni
FuSe BASeS FOR TyPe BAF / FNM / KTK / FNQ FuSeS APPROVeD
Base BM6032SQ
BM6032SQ base
codice IW
IW code
tipo
type
n. poli
poles
tipo fusibile
fuse range
2646001
2646002
2646003
BM6031SQ
BM6032SQ
BM6033SQ
1
2
3
0,5A p 30A
0,5A p 30A
0,5A p 30A
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
30A
30A
30A
600V
600V
600V
1
1
1
bCC 38 - portafusibili sezionabili per fusibili 10,3x38 Classe CC - Con omologazioni
BCC 38 - MoDuLaR FuSeHoLDeRS FoR 10,3x38 CLaSS CC FuSeS appRoVeD
BCC 1x38 fuseholder
tipo
type
n. poli
poles
n. moduli DIN
no. DIN modules
tipo fusibile
fuse type
2306138
2306238
2306338
2307138
2307238
2307338
BCC 1x38
BCC 2x38
BCC 3x38
SBCC 1x38 (1)
SBCC 2x38 (1)
SBCC 3x38 (1)
1
2
3
1
2
3
1
2
3
1
2
3
10 x 38
10 x 38
10 x 38
10 x 38
10 x 38
10 x 38
(1) Con indicatore luminoso
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
30A
30A
30A
30A
30A
30A
600V
600V
600V
600V
600V
600V
12-240
6-120
4-80
12-240
6-120
4-80
(1) With indicator light
ul / csa
Portafusibile BCC 1x38
codice IW
IW code
portafusibili per fusibili Classe J a 600V - Con omologazioni
FuSe BASeS FOR cLASS J 600V FuSeS APPROVeD
Base unipolare classe J
Single pole class J base
codice IW
IW code
tipo
type
n. poli
poles
tipo fusibile
fuse range
In (A)
In (A)
conf.
pack.
2680001
2680031
2680002
2680032
2680003
2680033
2680039
2680040
2680004
2680034
2680005
2680035
2680006
2680036
J60030-1S
J60030-3S
J60060-1C
J60060-3C
J60100-1CR
J60100-3CR
JM60100-1CR
JM60100-3CR
JM60200-1CR
JM60200-3CR
JM60400-1CR
JM60400-3CR
JM60600-1CR
JM60600-3CR
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1A p 30A
1A p 30A
35A p 60A
35A p 60A
70A p 100A
70A p 100A
70A p 100A
70A p 100A
110A p 200A
110A p 200A
225A p 400A
225A p 400A
450A p 600A
450A p 600A
30A
30A
60A
60A
100A
100A
100A
100A
200A
200A
400A
400A
600A
600A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N.B. Calotte coprifusibili vedi pagina 187
N.B. Fuse covers see page 187
portafusibili sezionabili per fusibili Classe J - Con omologazioni
MoDuLaR FuSeHoLDeRS FoR CLaSS J FuSeS appRoVeD
Portaf. sez. unipolare classe J
codice IW
IW code
tipo
type
n. poli
poles
larghezza (mm)
width (mm)
tipo fusibile
fuse type
31284
31285
31287
31920
31921
31922
BCJ 1x21
BCJ 2x21
BCJ 3x21
BCJ 1x27
BCJ 2x27
BCJ 3x27
1
2
3
1
2
3
36
72
108
40
80
120
21 x 57
21 x 57
21 x 57
27 x 60
27 x 60
27 x 60
In (A)
In (A)
Vn (V)
Vn (V)
conf.
pack.
30A
30A
30A
60A
60A
60A
600V
600V
600V
600V
600V
600V
6
3
2
6
3
2
Single pole class J fuseholder
185
Dimensioni di ingombro: pagine 203-204
Dimensions: pages 203-204
ITALWEBER
fusibili omologati per il nord-ameriCa
portafusibili per fusibili Classe “t” e per fusibili eXtrarapidi
noRTH-aMeRiCa appRoVeD FuSeS
FuSe BaSeS FoR CLaSS “T” FuSeS anD FoR HigH SpeeD FuSeS
Norme - Standards UL 248-13
Le basi portafusibili per i fusibili UL/CSA della classe T sono realizzate con materiali
termoplastici autoestinguenti UL-94 V0, e resistenti alle elevate temperature.
Possono essere utilizzate allo stesso valore di tensione sia in applicazioni in corrente alternata che in corrente continua. Il loro valore SCCR è di 200kA. Le basi modulari a blocchi, fornite in set da 2 pezzi, sono ideali per l’utilizzo con fusibili aventi le
lame forate, compresi i fusibili extrarapidi delle serie FWC, FWH, FWP e FWJ. Il loro
valore SCCR è pari al potere di interruzione del fusibile su di esse montato.
The fuse bases for uL/CSa fuses class T are made of self-extinguishing
thermoplastic uL 94-V0 materials. They can be used at the same voltage value
in both applications in alternating current and direct current. Their SCCR (Short
Circuit Current Rating) value is 200ka. The modular fuse blocks, provided in a
set of 2 pieces, are ideal for use with fuses with bolted blades, including the
high-speed fuses series FwC, FwH, Fwp and FwJ. Their SCCR is equal to the
breaking capacity of the fuse mounted on them.
portafusibili per fusibili Classe t a 300V - Con omologazioni
FuSe BASeS FOR cLASS T 300V FuSeS APPROVeD
Base unipolare
per fusibili classe T 300V
Single pole base
for class T 300V fuses
codice IW
IW code
tipo
type
n. poli
poles
tipo fusibile
fuse range
In (A)
In (A)
conf.
pack.
2680050
2680052
2680054
2680056
2680058
2680060
2680062
2680064
2680066
2680068
T30030-2SR
T30030-3SR
T30060-2SR
T30060-3SR
T30100-1CR
T30100-3CR
T30200-1C
T30200-3C
T30400-1C
T30600-1C
2
3
2
3
1
3
1
3
1
1
1A p 30A
1A p 30A
35A p 60A
35A p 60A
80A p 100A
80A p 100A
125A p 200A
125A p 200A
250A p 400A
450A p 600A
30A
30A
60A
60A
100A
100A
200A
200A
400A
600A
1
1
1
1
1
1
1
1
1
1
portafusibili per fusibili Classe t a 600V - Con omologazioni
FuSe BASeS FOR cLASS T 600V FuSeS APPROVeD
Base unipolare
per fusibili classe T 600V
Single pole base
for class T 600V fuses
codice IW
IW code
tipo
type
n. poli
poles
tipo fusibile
fuse range
In (A)
In (A)
conf.
pack.
2680070
2680072
2680074
2680076
2680078
2680080
2680082
2680084
2680086
2680088
T60030-1SR
T60030-3SR
T60060-1SR
T60060-3SR
T60100-1C
T60100-3C
T60200-1C
T60200-3C
T60400-1C
T60600-1C
1
3
1
3
1
3
1
3
1
1
1A p 30A
1A p 30A
35A p 60A
35A p 60A
80A p 100A
80A p 100A
125A p 200A
125A p 200A
250A p 400A
450A p 600A
30A
30A
60A
60A
100A
100A
200A
200A
400A
400A
1
1
1
1
1
1
1
1
1
1
basi a bloCChi serie bh - Con omologazioni
app
SeRieS BH MoDuLaR FuSeBLoCKS appRoVeD
Basi a blocchi BH
BH modular fuseblocks
186
codice IW
IW code
tipo
type
tipo fusibile
fuse type
1810571
1810509
1745032
1745033
1810414
1745034
BH-0112 (set 2 pz.)
BH-0122 (set 2 pz.)
BH-1132 (set 2 pz.)
BH-1133 (set 2 pz.)
BH-3144 (set 2 pz.)
BH-3145 (set 2 pz.)
FWH 35/60, FWP 35/60, FWX 35/100
FWH 70/100, FWP 70/100
FWH 125/200, FWX 125/300, FWJ 35/100
FWH 225/400, FWP 125/400, FWJ 125/400
FWP 450/600, LPJ 450/600, JKS 450/600, JJN 450/600, JJS 450/600
FWH 450/600, FWX 350/600, FWJ 500/600, LPJ 225/400, JKS 225/400
Dimensioni di ingombro: pagine 205-206
Dimensions: pages 205-206
Vn (V)
Vn (V)
conf.
pack.
max 700V
max 700V
max 2500V
max 2500V
max 1250V
max 1250V
1
1
1
1
1
1
ITALWEBER
fusibili omologati per il nord-ameriCa
Calotte per portafusibili
noRTH-aMeRiCa appRoVeD FuSeS
CoVeRS FoR FuSe BaSeS
Norme - Standards UL 248-13
Le calotte coprifusibili unipolari costituiscono una soluzione ottimale per la protezione degli utilizzatori contro i contatti accidentali. Sono disponibili nella versione
standard e nella versione con indicatore luminoso di fusione (tensione minima di
funzionamento: 90V AC / 115V DC). I modelli della serie CVR e CVRI sono realizzati in materiale termoplastico trasparente, mentre i modelli della serie SAMI sono
realizzati in materiale termoplastico di colore nero.
The single pole fuse covers are an ideal solution for the protection of users
against accidental contacts with live parts. They are available in the standard
version and in a version with a light indication of the fuse operation (minimum
operating voltage: 90V aC / 115V DC). The models CVR and CVRi are made of
transparent thermoplastic material, while the models of the SaMi series are
made of black colour thermoplastic material.
Calotte Coprifusibili per basi Classe h e Classe r - Con omologazioni
FuSe CoVeRS FoR CLaSS H anD CLaSS R BaSeS appRoVeD
app
Calotta coprifusibile
Fuse cover
tipo standard
standard type
codice IW
tipo
IW code
type
tipo con indicatore
type with indicator
codice IW
tipo
IW code
type
tipo base
fuse base type
2680100
2680102
2680104
2680106
2680108
2680110
2680112
2680114
2680100S
2680102S
2680104S
2680106S
2680108S
2680110S
2680112S
2680114S
HM25100 / RM25100
HM25200 / RM25200
HM25400 / RM25400
HM25600 / RM25600
HM60100 / RM60100
HM60200 / RM60200
HM60400 / RM60400
HM60600 / RM60600
CVR-RH-25100
CVR-RH-25200
CVR-RH-25400
CVR-RH-25600
CVR-RH-60100
CVR-RH-60200
CVR-RH-60400
CVR-RH-60600
CVRI-RH-25100
CVRI-RH-25200
CVRI-RH-25400
CVRI-RH-25600
CVRI-RH-60100
CVRI-RH-60200
CVRI-RH-60400
CVRI-RH-60600
Vn (V)
Vn (V)
conf.
pack.
250V
250V
250V
250V
600V
600V
600V
600V
1
1
1
1
1
1
1
1
Vn (V)
Vn (V)
conf.
pack.
600V
600V
600V
600V
1
1
1
1
Vn (V)
Vn (V)
conf.
pack.
600V
600V
600V
600V
600V
600V
600V
600V
600V
1
1
1
1
1
1
1
1
1
Calotta coprifusibile
Fuse cover
tipo standard
standard type
codice IW
tipo
IW code
type
tipo con indicatore
type with indicator
codice IW
tipo
IW code
type
tipo base
fuse base type
2680120
2680122
2680124
2680126
2680120S
2680122S
2680124S
2680126S
JM60100
JM60200
JM60400
JM60600
CVR-J-60100
CVR-J-60200
CVR-J-60400
CVR-J-60600
CVRI-J-60100
CVRI-J-60200
CVRI-J-60400
CVRI-J-60600
Calotte Coprifusibili serie sami - Con omologazioni
app
SeRieS SaMi FuSe CoVeRS appRoVeD
Calotta coprifusibile SAMI
SaMi fuse cover
codice IW
IW code
tipo
type
tipo fusibile
fuse type
1810481
1810702
1810482
1811730
1810703
1810498
1810386 (1)
1810806
1810735
SAMI-1N
SAMI-2N
SAMI-3N
SAMI-4N
SAMI-5N
SAMI-6N
SAMI-7N
SAMI-8N
SAMI-9N
FRN-R 35/60, NON 35/60, LPJ-SP 0/30, JKS 0/30
FRS-R 0/30, NOS 0/30
LPJ-SP 65/100, JKS 65/100
FRN-R 70/100, NON 70/100
FRS-R 35/60, NOS 35/60
LPJ-SP 35/60, JKS 35/60
BAF 0/30, FNM 0/30, FNQ-R 0/30, KTK 0/30
FRS-R 70/100, NOS 70/100
FRN-R 0/30, NON 0/30
(1) Tipo non omologato
187
(1) Type without any approval
ITALWEBER
ul / csa
Calotte Coprifusibili per basi Classe J - Con omologazioni
FuSe CoVeRS FoR CLaSS J BaSeS appRoVeD
app
dimensioni e CaratteristiChe
fusibili Classi “k5”-“h”-“rk5” a 250V e 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSSeS “K5”-”H”-”RK5” FuSeS aT 250V anD 600V
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili Classi “k5”-“h”-“rk5” a 250V e 600V
CLaSSeS “K5”-”H”-”RK5” FuSeS aT 250V anD 600V
Fig. 1 - Fusibili 0,5A÷30A - Fig. 1 - 0,5a÷30a fuses
Fig. 2 - Fusibili 35A÷60A - Fig. 2 - 35a÷60a fuses
Fig. 3 - Fusibili 65A÷600A serie F - Fig. 3 - 65a÷600a series F fuses
Fig. 4 - Fusibili 65A÷600A serie T - Fig. 4 - 65a÷600a series T fuses
serie
series
“F” 250V
“F” 600V
“T” 250V
“T” 600V
188
tipo
type
fig.
Ik (kA)
Ik (kA)
A
B
C
D
E
UL-14F
UL-20F
UL-27F
UL-40F
UL-53F
UL-66F
UL-20F
UL-27F
UL-34F
UL-46F
UL-66F
UL-80F
UL-14T
UL-20T
UL-27T
UL-40T
UL-53T
UL-66T
UL-20T
UL-27T
UL-34T
UL-46T
UL-66T
UL-80T
1
2
3
3
3
3
1
2
3
3
3
3
1
2
4
4
4
4
2
2
4
4
4
4
50
50
10
10
10
10
50
50
10
10
10
10
200
200
200
200
200
200
200
200
200
200
200
200
51
76
149
181
219
264
127
139
200
244
295
340
51
76
149
181
219
264
127
139
200
244
295
340
14,0
21,0
27,0
40,0
53,0
66,0
21,0
27,0
34,0
46,0
66,0
80,0
14,0
21,0
27,0
40,0
53,0
66,0
21,0
27,0
34,0
46,0
66,0
80,0
—
—
3
5
6
6
—
—
3
5
6
6
—
—
3
5
6
6
—
—
3
5
6
6
—
—
19
28
41
51
—
—
19
28
41
51
—
—
19
28
41
51
—
—
19
28
41
51
—
—
25
35
48
57
—
—
25
35
48
57
—
—
25
35
48
57
—
—
25
35
48
57
ITALWEBER
dimensioni e CaratteristiChe
fusibili Classi “k5”-“h”-“rk5” a 250V e 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSSeS “K5”-”H”-”RK5” FuSeS aT 250V anD 600V
Caratteristiche tecniche - Technical characteristics
fusibili Classi “k5”-“h”-“rk5” a 250V e 600V
CLaSSeS “K5”-”H”-”RK5” FuSeS aT 250V anD 600V
Caratt. d’intervento serie T 250V - Time-current characteristics series T 250V
Caratt. d’intervento serie F 600V - Time-current characteristics series F 600V
Caratt. d’intervento serie T 600V - Time-current characteristics series T 600V
ul / csa
Caratt. d’intervento serie F 250V - Time-current characteristics series F 250V
189
ITALWEBER
dimensioni e CaratteristiChe
fusibili Classe “supplemental” a 250V e 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSS “SuppLeMenTaL” FuSeS aT 250V anD 600V
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili “supplemental” a 250V e 600V
“SuppLeMenTaL” FuSeS aT 250V anD 600V
Caratteristica d’intervento fusibili BAF
Time-current characteristics BaF fuses
Caratteristica d’intervento fusibili FNQ
Time-current characteristics FnQ fuses
190
Caratteristica d’intervento fusibili FNM
Time-current characteristics FnM fuses
Caratteristica d’intervento fusibili KTK
Time-current characteristics KTK fuses
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
tipo
type
Vn (V)
Vn (V)
Ik (kA)
Ik (kA)
BAF
FNM
KTK
FNQ
250
250
600
500
(1)
(2)
100
10
A
B
38
38
38
38
10,3
10,3
10,3
10,3
(1) Potere di interruzione:
35A (fusibili 1A / tensione 250V)
100A (fusibili da 2A a 3A / tensione 250V)
200A (fusibili da 4A a 10A / tensione 250V)
750A (fusibili da 12A a 15A / tensione 250V)
200A (fusibili da 20A a 30A / tensione 250V)
10.000A (fusibili da 1A a 30A / tensione 125V)
(1) Breaking capacity:
35A (fuse 1A / voltage 250V)
100A (fuses from 2A to 3A / voltage 250V)
200A (fuses from 4A to 10A / voltage 250V)
750A (fuses from 12A to 15A / voltage 250V)
200A (fuses from 20A to 30A / voltage 250V)
10.000A (fuses from 1A to 30A / voltage 125V)
2) Potere di interruzione:
35A (fusibili 1A / tensione 250V)
100A (fusibili da 2A a 3A / tensione 250V)
200A (fusibili da 4A a 10A / tensione 250V)
10.000A (fusibili da 12A a 30A / tensione 250V)
10.000A (fusibili da 1A a 30A / tensione 125V)
(2) Breaking capacity:
35A (fuse 1A / voltage 250V)
100A (fuses from 2A to 3A / voltage 250V)
200A (fuses from 4A to 10A / voltage 250V)
10.000A (fuses from 12A to 30A / voltage 250V)
10.000A (fuses from 1A to 30A / voltage 125V)
ITALWEBER
dimensioni e CaratteristiChe
fusibili Classe “CC” a 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSS “CC” aT 600V FuSeS
Caratteristiche tecniche - Technical characteristics
fusibili Classe “CC” 600V
CLaSS “CC” 600V FuSeS
Caratt. d’intervento fusibili KTK-R - Time-current characteristics KTK-R fuses
1A
sec.
2A 3A
5A
Caratt. d’intervento fusibili LP-CC - Time-current characteristics Lp-CC fuses
8A 10A 15A 30A
300
200
100
50
20
10
5
2
1
0,5
0,2
0,1
0,05
0,02
2
1
5
10
5 2
100
ul / csa
0,01
I
5 2
A
1/2
6/10
3/4
8/10
1
1-1/8
1-1/4
1/2
1-1/2
6/10
1-8/10
3/4
2 8/10
1
2-1/2
3 1-1/8
1-1/4
3-2/10
1-1/2
3-1/2
4 1-8/10
5 2
2-1/2
5-6/10
6 3
6-1/4
3-2/10
7 3-1/2
4
7-1/2
5
5-6/10
6
6-1/4
7
7-1/2
Caratteristiche d’intervento fusibili FNQ-R - Time-current characteristics FnQ-R fuses
1
10
1
30A
1
.1
10000
1000
CURRENT IN AMPERES
CURRENT IN AMPERES
10000
1000
100
100
.01
10
.01
1
CURRENT IN AMPERES
CURRENT IN AMPERES
300
400
500
300
100
400
500
200
200
100
10
10
.5
1
.01
1
.1
.5
10
.1
.1
191
TIME IN SECONDS
TIME IN SECONDS
TIME IN SECONDS
TIME IN SECONDS
10
10
.01
15A
20A
100
100
1
30A
15A
20A
1000
10
100
1000
100
1
200
AMPERE
AMPERE RATING
RATING
200
ITALWEBER
dimensioni e CaratteristiChe
fusibili Classe “J” a 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSS “J” aT 600V FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili Classe “J” 600V
CLaSS “J” 600V FuSeS
Dimensioni in mm fusibili 1A÷60A - Dimensions in mm 1a÷60a fuses
Dimensioni in mm fusibili 65A÷600A - Dimensions in mm 65a÷600a fuses
tipo
type
In (A)
In (A)
Ik (kA)
Ik (kA)
A
B
C
D
E
F
G
H
WPJ-21 / DFJ-21
WPJ-27 / DFJ-27
WPJ-29 / DFJ-29
WPJ-41 / DFJ-41
WPJ-54 / DFJ-54
WPJ-64 / DFJ-64
1A - 30A
35A - 60A
70A - 100A
110A - 200A
225A - 400A
450A - 600A
300
300
300
300
300
300
57
60
117
146
181
203
21
27
29
41
54
64
–
–
3,2
4,8
6,3
9,5
–
–
19
29
41
51
–
–
25
35
48
54
–
–
92
111
133
152
–
–
10
10
14
18
–
–
7
7
10
13
Caratt. d’intervento fusibili LPJ - Time-current characteristics LpJ fuses
Caratt. di limitazione fusibili LPJ - Cut-off characteristics LpJ fuses
I (A)
600A
15A
20A
30A
40A
50A
60A
100A
125A
200A
225A
400A
10A
5A
300
3A
1A
T (s)
B
100,000
600A
400A
100
200A
100A
60A
50A
40A
30A
20A
15A
10,000
10
1,000
1
A
.01
192
I (A)
100
.1
100
1,000
10,000
100,000 200,000
I (A)
1
10
100
1.000
10.000
ITALWEBER
dimensioni e CaratteristiChe
fusibili Classe “J” a 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSS “J” aT 600V FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili Classe “J” 600V
CLaSS “J” 600V FuSeS
100
00
400
100
60
400
200
10
100
60
30
10,000
A
10
30
200,000
A
200,000
-1
1
100,000
1,000
1,000
10,000
-1
-01
193
ITALWEBER
1,000
Caratt. di limitazione fusibili DFJ - Cut-off characteristics DFJ fuses
40
Caratt. d’intervento fusibili DFJ - Time-current characteristics DFJ fuses
ul / csa
10,000
1,000
100
40
-01
100
100,000
1
10,000
1,000
400A
600A
600
200
00
200A
100
100,000
600
00
300
100A
B
400,000
60A
Caratt. di limitazione fusibili JKS - Cut-off characteristics JKS fuses
30A
400A
600A
200A
300
100A
30A
B
00
60A
Caratt. d’intervento fusibili JKS - Time-current characteristics JKS fuses
dimensioni e CaratteristiChe
fusibili Classe “rk1” a 250V e 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSS “RK1” aT 250V anD 600V FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili Classe “rk1” a 250V e 600V
CLaSS “RK1” aT 250V anD 600V FuSeS
Dimensioni in mm fusibili KTN-R - Dimensions in mm KTn-R fuses
Dimensioni in mm fusibili KTS-R - Dimensions in mm KTS-R fuses
Fig. 1
Fig. 1
Fig. 2
Fig. 2
In (A)
In (A)
fig.
fig.
Ik (kA)
Ik (kA)
A
B
In (A)
In (A)
fig.
fig.
Ik (kA)
Ik (kA)
A
B
1A - 30A
35A - 60A
70A - 100A
110A - 200A
225A - 400A
450A - 600A
1
1
2
2
2
2
300
300
300
300
300
300
51
76
149
181
219
262
14
21
27
40
53
66
1A - 30A
35A - 60A
70A - 100A
110A - 200A
225A - 400A
450A - 600A
1
1
2
2
2
2
300
300
300
300
300
300
127
139
200
244
295
340
21
27
34
46
66
80
Caratt. d’intervento fusibili KTN-R - Time-current characteristics KTn-R fuses
194
Caratt. d’intervento fusibili KTS-R - Time-current characteristics KTS-R fuses
ITALWEBER
dimensioni e CaratteristiChe
fusibili Classe “t” a 300V e 600V
DiMenSionS anD SpeCiFiCaTionS
CLaSS “T” aT 300V anD 600V FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili Classe “t” a 300V e 600V
CLaSS “T” aT 300V anD 600V FuSeS
Dimensioni in mm fusibili JJS - Dimensions in mm JJs fuses
Fig. 1
Fig. 1
Fig. 2
Fig. 2
In (A)
In (A)
fig.
fig.
Ik (kA)
Ik (kA)
A
B
In (A)
In (A)
fig.
fig.
Ik (kA)
Ik (kA)
A
B
1A - 30A
35A - 60A
70A - 100A
110A - 200A
225A - 400A
450A - 600A
1
1
2
2
2
2
200
200
200
200
200
200
22,4
22,4
54,8
62,0
69,9
77,8
10,4
14,2
19,0
22,4
25,4
31,8
1A - 30A
35A - 60A
70A - 100A
110A - 200A
225A - 400A
450A - 600A
1
1
2
2
2
2
200
200
200
200
200
200
38,0
39,0
75,0
82,5
92,0
102,0
10,3
20,5
19,0
22,3
25,4
31,8
Caratt. d’intervento fusibili JJN - Time-current characteristics JJn fuses
195
Caratt. d’intervento fusibili JJS - Time-current characteristics JJS fuses
ITALWEBER
ul / csa
Dimensioni in mm fusibili JJN - Dimensions in mm JJn fuses
dimensioni e CaratteristiChe
fusibili tipo “klm” e tipo “dmm-b”
DiMenSionS anD SpeCiFiCaTionS
Type “KLM” anD Type “DMM-B” FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili serie “klm”
SeRieS “KLM” FuSeS
Caratt. d’intervento tempo corrente - Time-current characteristics
fusibili serie “dmm-b”
SeRieS “DMM-B” FuSeS
Caratt. d’intervento tempo corrente - Time-current characteristics
Dimensioni in mm - Dimensions in mm
tipo - type
DMM-B-44/100
DMM-B-11
196
A
34,9 (±0,79)
38,1 (±0,79)
ITALWEBER
dimensioni e CaratteristiChe
fusibili eXtrarapidi serie “fWX”
DiMenSionS anD SpeCiFiCaTionS
HigH SpeeD SeRieS “Fwx” FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili serie “fWX”
SeRieS “Fwx” FuSeS
Dimensioni in mm - Dimensions in mm
Fig. 2
Fig. 1
Fig. 3
fig.
A
B
C
D
E
F
G
H
J
FWX-35/60A
FWX-70/200A
FWX-225/600A
FWX-700/800A
FWX-1000/1200AH
FWX-1500/2500AH
1
1
1
1
2
3
81,0
79,5
97,5
97,5
65,8
65,8
20,6
31,0
38,1
50,8
76,2
88,9
40,4
40,4
40,4
40,4
38,1
38,1
65,8
62,0
74,7
76,9
–
38,1
57,1
55,6
57,1
57,9
–
–
8,6
8,6
10,4
10,4
–
–
16,0
25,4
25,4
38,1
–
–
3,3
4,8
6,4
6,4
–
–
13,2
11,9
19,0
19,8
–
–
ul / csa
fusibili - fuses
Caratt. d’intervento tempo corrente - Time-current characteristics
197
ITALWEBER
dimensioni e CaratteristiChe
fusibili eXtrarapidi serie “fWh”
DiMenSionS anD SpeCiFiCaTionS
HigH SpeeD SeRieS “FwH” FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili serie “fWh”
SeRieS “FwH” FuSeS
Dimensioni in mm - Dimensions in mm
Fig. 2 1400A, 1600A
Fig. 1
fusibili - fuses
fig.
A
B
C
D
E
F
G
H
J
FWH-35/60B
FWH-70/100B
FWH-125/200B
FWH-225/400A
FWH-450/600A
FWH-700/800A
FWH-1000/1200A
1
1
1
1
1
1
1
81,0
92,1
92,1
110,2
110,2
161,0
177,0
20,6
24,0
29,4
38,1
50,8
63,5
76,2
40,5
44,1
46,6
53,1
53,1
53,1
81,8
64,5
72,5
73,5
87,4
89,7
126,2
138,8
57,5
71,3
70,3
69,8
70,6
77,4
113,7
8,7
8,9
8,7
10,4
10,4
13,5
15,9
18,3
19,0
25,4
25,4
38,1
50,8
60,3
3,2
3,2
4,8
6,4
6,4
9,7
11,1
13,1
9,5
10,3
19,0
19,8
33,0
28,5
Caratt. d’intervento tempo corrente - Time-current characteristics
198
ITALWEBER
dimensioni e CaratteristiChe
fusibili eXtrarapidi serie “fWp”
DiMenSionS anD SpeCiFiCaTionS
HigH SpeeD SeRieS “Fwp” FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili serie “fWp”
SeRieS “Fwp” FuSeS
Dimensioni in mm - Dimensions in mm
Fig. 1
Fig. 3 1200A
Fig. 2 900A, 1000A
fig.
A
B
C
D
E
F
G
H
J
FWP-5/30B
FWP-35/60B
FWP-70/100B
FWP-125/200A
FWP-225/400A
FWP-450/600A
FWP-700/800A
1
1
1
1
1
1
1
72,9
111,1
111,8
129,3
129,3
180,0
168,4
14,3
20,6
24,0
38,1
50,8
63,5
50,8
47,1
69,8
65,9
72,1
72,1
72,1
72,2
62,9
94,2
92,0
106,4
108,7
145,3
141,3
62,9
84,1
90,5
88,9
89,7
106,4
128,6
6,4
8,7
8,7
10,4
10,4
13,5
15,9
10,3
18,4
19,0
25,4
38,1
50,8
38,1
1,6
3,2
3,2
6,4
6,4
9,6
6,4
6,4
13,8
9,5
19,0
19,8
33,0
22,2
ul / csa
fusibili - fuses
Caratt. d’intervento tempo corrente - Time-current characteristics
199
ITALWEBER
dimensioni e CaratteristiChe
fusibili eXtrarapidi serie “fWJ”
DiMenSionS anD SpeCiFiCaTionS
HigH SpeeD SeRieS “FwJ” FuSeS
Dimensioni in mm e caratteristiche tecniche - Dimensions in mm and technical characteristics
fusibili serie “fWJ”
SeRieS “FwJ” FuSeS
Dimensioni in mm - Dimensions in mm
Fig. 1
fusibili - fuses
fig.
A
B
C
D
E
F
G
H
J
FWJ-35/60A
FWJ-70/100A
FWJ-125/200A
FWJ-250/400A
FWJ-500/600AH
FWJ-800/2000AH
1
1
1
1
1
1
127,0
125,3
144,4
146,5
183,0
173,0
23,9
28,6
38,8
50,8
63,5
88,9
79,0
78,4
82,8
88,9
88,0
84,1
107,6
108,4
122,0
122,2
152,0
139,0
106,2
105,6
103,0
105,4
119,5
126,0
8,9
8,9
11,3
11,0
14,3
15,9
19,0
25,4
25,4
38,1
50,8
69,9
3,2
4,8
6,4
6,4
9,5
12,7
9,6
10,3
20,8
19,4
30,5
22,4
Caratt. d’intervento tempo corrente - Time-current characteristics
200
ITALWEBER
dimensioni e CaratteristiChe
portafusibili per fusibili Classe “k5”-“h”-“rk5”-“rk1” 250V
DiMenSionS anD SpeCiFiCaTionS
FuSeHoLDeRS FoR FuSeS CLaSS “K5”-“H”-“RK5”-“RK1” - 250V
Dimensioni in mm - Dimensions in mm
portafusibili per fusibili Classe “k5”-“h”-“rk5”-“rk1” - 250V
FuSeHoLDeRS FoR FuSeS CLaSS “K5”-“H”-“RK5”-“RK1” - 250V
Portafusibili per fusibili 35-60A - Fuseholders for fuses 35-60a
Portafusibili per fusibili 70-100A - Fuseholders for fuses 70-100a
Portafusibili tipo M per fus. 70-100A - Fuseholders M type for fuses 70-100a
Portafusibili tipo M per fus. 110-200A - Fuseholders M type for fuses 110-200a
Portafusibili tipo M per fus. 225-400A - Fuseholders M type for fuses 225-400a
ul / csa
Portafusibili per fusibili 0,5-30A - Fuseholders for fuses 0,5-30a
Portafusibili tipo M per fus. 450-600A - Fuseholders M type for fuses 450-600a
201
ITALWEBER
dimensioni e CaratteristiChe
portafusibili per fusibili Classe “k5”-“h”-“rk5”-“rk1” 600V
DiMenSionS anD SpeCiFiCaTionS
FuSeHoLDeRS FoR FuSeS CLaSS “K5”-“H”-“RK5”-“RK1” - 600V
Dimensioni in mm - Dimensions in mm
portafusibili per fusibili Classe “k5”-“h”-“rk5”-“rk1” - 600V
FuSeHoLDeRS FoR FuSeS CLaSS “K5”-“H”-“RK5”-“RK1” - 600V
Portafusibili per fusibili 0,5-30A - Fuseholders for fuses 0,5-30a
Portafusibili per fusibili 35-60A - Fuseholders for fuses 35-60a
Portafusibili per fusibili 70-100A - Fuseholders for fuses 70-100a
Portafusibili tipo M per fus. 70-100A - Fuseholders M type for fuses 70-100a
Portafusibili tipo M per fus. 110-200A - Fuseholders M type for fuses 110-200a
Portafusibili tipo M per fus. 225-400A - Fuseholders M type for fuses 225-400a
Portafusibili tipo M per fus. 450-600A - Fuseholders M type for fuses 450-600a
202
ITALWEBER
dimensioni e CaratteristiChe
portafusibili per fusibili Classe “CC” e Classe “J”
DiMenSionS anD SpeCiFiCaTionS
FuSeHoLDeRS FoR FuSeS CLaSS “CC” anD CLaSS “J”
Dimensioni in mm - Dimensions in mm
86
81
45
portafusibili per fusibili Classe “CC”
FuSeHoLDeRS FoR FuSeS CLaSS “CC”
37
58
17,8
35,6
53,4
portafusibili per fusibili Classe “J”
FuSeHoLDeRS FoR FuSeS CLaSS “J”
ul / csa
Portafusibili per fusibili 21x57 classe J - Fuseholders for 21x57 class J fuses
Portafusibili per fusibili 27x60 classe J - Fuseholders for 27x60 class J fuses
203
ITALWEBER
dimensioni e CaratteristiChe
portafusibili per fusibili Classe “J ”
DiMenSionS anD SpeCiFiCaTionS
FuSeHoLDeRS FoR FuSeS CLaSS “J”
Dimensioni in mm - Dimensions in mm
portafusibili per fusibili Classe “J”
FuSeHoLDeRS FoR FuSeS CLaSS “J”
Portafusibili per fusibili 1-60A - Fuseholders for fuses 1-60a
Portafusibili per fusibili 70-100A - Fuseholders for fuses 70-100a
Portafusibili tipo M per fus. 70-100A - Fuseholders M type for fuses 70-100a
Portafusibili tipo M per fus. 110-200A - Fuseholders M type for fuses 110-200a
Portafusibili tipo M per fus. 225-400A - Fuseholders M type for fuses 225-400a
Portafusibili tipo M per fus. 450-600A - Fuseholders M type for fuses 450-600a
portafusibili per fusibili 10x38 - 600V
FuSeHoLDeRS FoR 10x38 FuSeS - 600V
Portaf. 1P BM6031SQ - 1p fuseholders BM6031SQ
204
Portaf. 2P BM6032SQ - 2p fuseholders BM6032SQ
Portaf. 3P BM6033SQ - 3p fuseholders BM6033SQ
ITALWEBER
dimensioni e CaratteristiChe
portafusibili per fusibili Classe “t” - 300V
DiMenSionS anD SpeCiFiCaTionS
FuSeHoLDeRS FoR FuSeS CLaSS “T” - 300V
Dimensioni in pollici - Dimensions in inches
portafusibili per fusibili Classe “t” - 300V
FuSeHoLDeRS FoR FuSeS CLaSS “T” - 300V
Portafusibili per fusibili 1-60A - Fuseholders for fuses 1-60a
tipo - type
T30030-2
T30060-2
T30030-3
T30060-3
A
B
C
2,41
–
1,03
3,44
1,03
2,06
Portafusibili per fusibili 125-200A - Fuseholders for fuses 125-200a
Portafusibili per fusibili 250-400A - Fuseholders for fuses 250-400a
Portafusibili per fusibili 450-600A - Fuseholders for fuses 450-600a
ul / csa
Portafusibili per fusibili 80-100A - Fuseholders for fuses 80-100a
205
ITALWEBER
dimensioni e CaratteristiChe
portafusibili per fusibili Classe “t” - 600V
DiMenSionS anD SpeCiFiCaTionS
FuSeHoLDeRS FoR FuSeS CLaSS “T” - 600V
Dimensioni in pollici - Dimensions in inches
portafusibili per fusibili Classe “t” - 600V
FuSeHoLDeRS FoR FuSeS CLaSS “T” - 600V
Portafusibili per fusibili 1-30A - Fuseholders for fuses 1-30a
Portafusibili per fusibili 35-60A - Fuseholders for fuses 35-60a
Portafusibili per fusibili 80-100A - Fuseholders for fuses 80-100a
Portafusibili per fusibili 125-200A - Fuseholders for fuses 125-200a
Portafusibili per fusibili 250-400A - Fuseholders for fuses 250-400a
Portafusibili per fusibili 450-600A - Fuseholders for fuses 450-600a
206
ITALWEBER
Scarica

norme UL/CSA UL/CSA standards