Service BINOVA -------------------------------------------------------------------------------------------------------- CIRCUITO GAS CAMERA STAGNA / APERTA VALVOLA GAS MOD. SGV 100 B&P Service • COMPITO • – APRIRE E CHIUDERE IL GAS AL BRUCIATORE – REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE – INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE CARATTERISTICHE – DIMENSIONI COMPATTE – PRIVA DI ORGANI MECCANICI DI TARATURA; – A BASSA RUMOROSITA’ – MODELLO SGV 100 B&P – MODULATORE DA 1 a 37 mbar – TEMPERATURA -15°/ + 60° – ALIMENTAZIONE DEGLI OPERATORI A 24 Vdc. – RESISTENZA EV1 DI 25 OHM ( 1 e 3 ) – RESISTENZA EV2 DI 67 OHM ( tra 2 e 4) BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (1) – VERIFICARE PRESSIONE DI RETE (sia statica che dinamica) UTILIZZANDO LA PRESA DI PRESSIONE IN INGRESSO ALLA VALVOLA GAS (1); – COLLEGARE IL MANOMETRO SULLA PRESA D’ USCITA VALVOLA GAS (2); – LA PROCEDURA DI TARATURA SI COMPONE DELLE SEGUENTI FASI: 2 1 BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (2) – TARATURA PORTATA TERMICA MASSIMA: • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMERE CONTEMPORANEAMENTE I SEGUENTI TASTI: A + B + C PER 10 sec • FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO D A E B C RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (3) – TARATURA PORTATA TERMICA MASSIMA: • SCORRERE I PARAMETRI PREMENDO IL TASTO A FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P09. D A E B C RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (4) – TARATURA PORTATA TERMICA MASSIMA: • VARIARE A 15 IL VALORE DEL PARAMETRO P09 PREMENDO IL TASTO D • MEMORIZZARE IL VALORE 15 IMPOSTATO PREMENDO IL TASTO C D A E B C RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (5) – TARATURA PORTATA TERMICA MASSIMA: • SUL DISPLAY COMPARIRA’ S-H ALTERNATO AL VALORE DI POTENZA MASSIMA; • VARIARE IL VALORE DI TARATURA AGENDO SUL TASTO A • VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE • SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA D A E B 1 RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (5) – TARATURA PORTATA TERMICA MASSIMA: • CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. • RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN SALITA; • MEMORIZZARE LA TARATURA PREMENDO PER UN SECONDO IL TASTO E (FINO A CHE IL VALORE NON RIMANE FISSO) D A E B RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (6) – TARATURA PORTATA TERMICA MINIMA: • PER PASSARE ALLA TARATURA MINIMA PREMERE IL TASTO D • NEL DISPLAY COMPARIRA’ LA SCRITTA S-L (taratura minima) ALTERNATO AL VALORE ELETTRONICO DI TARATURA D A E B C RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (7) – TARATURA PORTATA TERMICA MINIMA: • VARIARE IL VALORE DI TARATURA AGENDO SUL TASTO B • VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE • SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA D A E B 1 C RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA TARATURA GAS (8) – TARATURA PORTATA TERMICA MINIMA: • CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. • RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN DISCESA; • MEMORIZZARE LA TARATURA PREMENDO PER UN SECONDO IL TASTO E (FINO A CHE IL VALORE NON RIMANE FISSO) D A E B C RinNOVA BINOVA –CIRCUITO GAS TARATURE GAS Service • VALORI TARATURA GAS BINOVA: MODELLO (S) M297.24CM-24 kw Min (mbar) Max (mbar) Metano 2,40 12,70 Butano 5,40 Propano 7,00 MODELLO (A) M297.24BM-24 kw Min (mbar) Max (mbar) Metano 2,80 12,90 28,00 Butano 6,80 29,90 35,10 Propano 8,90 37,20 BINOVA –CIRCUITO GAS UGELLI Service COLLETTORE GAS CON UGELLI • DATI BRUCIATORE – 24CM N° 11 RAMPE – 24BM N° 11 RAMPE • UGELLI METANO – 24CM = n° 11 X 1,30 – 24BM = n° 11 X 1,25 • UGELLI GPL – 24CM= 11 X 0,79 – 24BM= 11 X 0,76 BINOVA –CIRCUITO GAS ELETTRODO D’ACCENSIONE E RILEVAZIONE Service • COMPITO – INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS ED INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA DI ACCENSIONE – FORNIRE UN SEGNALAZIONE DI RETROAZIONE ALLA SCHEDA CHE PERMETTA DI RICONOSCERE SE LA COMBUSTIONE E’ IGENICA (SISTEMA GARC). TALE SISTEMA SOSTITUISCE L’UTILIZZO DEL PRESSOSTATO FUMI PER CALDAIE STAGNE. • CARATTERISTICHE – – – – CORPO IN CERAMICA ELETTRODO IN KANTAL POSIZIONATO CENTRALMENTE AL BRUCIATORE SCARICA ESEGUITA TRA ELETTRODO E BRUCIATORE BINOVA –CIRCUITO GAS TARATURE GAS • Service PROCEDURA CAMBIO GAS (1) A) SOSTITUIRE GLI UGGELLI AL BRUCIATORE; B) CONFIGURARE LA SCHEDA PER IL TIPO DI GAS UTILIZZATO. • ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMERE CONTEMPORANEAMENTE I TASTI A + B + C FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO D A E B C BINOVA –CIRCUITO GAS TARATURE GAS Service • PROCEDURA CAMBIO GAS (2) • SCORRERE I PARAMETRI PREMENDO IL TASTO A • FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P05. D A E B C BINOVA –CIRCUITO GAS CAMBIO GAS Service • PROCEDURA CAMBIO GAS (3) • MODIFICARE IL VALORE DEL PARAMETRO P05 TRAMITE IL TASTO A FINO A FAR APPARIRE IL VALORE IN FUNZIONE AL TIPO DI GAS SEGUENDO LA TABELLA SOTTO RIPORTATA: • MEMORIZZARE IL VALORE PREMENDO IL TASTO C D A E B A C BINOVA –CIRCUITO GAS VENTILATORE Service • COMPITO – EVACUARE I PRODOTTI DELLA COMBUSTIONE – ASSENZA DEL VENTURI: IL SISTEMA GARC, DI CUI LA CALDAIA E’ DOTATA, NON SI BASA SUL SEGNALE DEL PRESSOSTATO • DATI DEL MODELLO 24 KW – MODELLO LN NATALINI – ALIMENTAZIONE 220 VC.A. – POTENZA: • 24 KW = 33 W / 63 OHM BINOVA –CIRCUITO GAS SISTEMA G.A.R.C. Service • CARATTERISTICHE – IL SISTEMA GARC E’ COMPOSTO DAI SEGUENTI COMPONENTI: • SCHEDA ELETTRONICA; • ELETTRODO DI ACCENSIONE/RILEVAZIONE – PERMETTE DI GARANTIRE PARAMETRI DI COMBUSTIONE CORRETTI, SENZA L’UTILIZZO DEL PRESSOSTATO FUMI. – BASA IL SUO FUNZIONAMENTO SUL SEGNALE DI RETROAZIONE (CORRENTE DI IONIZZAZIONE) PROVENIENETE DALL’ELETTRODO DI ACCENSIONE. TALE SEGNALE COMUNICA ALLA SCHEDA SE LA COMBUSTIONE E’ CORRETTA O MENO. – IN CASO DI COMBUSTIONE NON CORRETTA, LA SCHEDA ESEGUE DEI CONTROLLI, E IN BASE ALL’ANOMALIA RISCONTRATA, EVIDENZIA I SEGUENTI ERRORI: • BLOCCO PER ANOMALIA COMBUSTIONE IN ACCENSIONE; • BLOCCO PER ANOMALIA COMBUSTIONE IN FUNZIONAMENTO; • ANOMALIA COMBUSTIONE - CALDAIA IN LIMITAZIONE DI POTENZA; BINOVA –CIRCUITO GAS MODELLI A CAMERA APERTA Service CAPPA FUMI • • COMPITO – CONVOGLIA I FUMI NELLA CANNA FUMARIA CARATTERISTICHE – DIAMETRO DI 130 mm TERMOSTATO FUMI • • COMPITO – VERIFICARE CORRETTO TIRAGGIO CANNA FUMARIA CARATTERISTICHE – RIARMO AUTOMATICO: • TEMPERATURA OFF 63°C • TEMPERATURA ON – IN CASO DI INTERVENTO ANOMALIA DISPLAY: Er05 BINOVA –CIRCUITO GAS